LOAD CARRYING CAPACITY OF PILES (STATIC ANALYSIS)

For Cast In Situ Bored Piles (As per IS 2911 (Part 1/Sec 2) : 2010)
(Considering GWT at EGL)
Site - Proposed Factory Shed of Bengal Beverages Pvt Ltd at Paraj, Burdwan, West Bengal
EGL (±) 0.00m EGL
Cut off LVL = (-) 1.5 m

Toe LVL at (-) 12 m from EGL


ST- I, Total Depth = 9.0m C= 4.00 ton/m2, γ = 1.88 ton/m3, α = 1.00

ST- II, Total Depth = 1.0 m ɸ= 340, γ = 1.98 ton/m3, K = 1, δ = (340- 30) = 310

Pile Dia (D) = 600 mm


Pile Length (L) = 10.00 m from EGL
Cut off Length = 1.5 m
Ultimate Capacity Due to End Bearing Resistance
End Stratum => Clay *φ' = (φ - 3) = 0 deg
Pile should be atleast embedded 4 times
C= 4 t/m2
of its diameter into the end stratum]
ϒ = 1.88 t/m3

Here the End Stratum is Clay


Therefore, End Bearing Resistance = = 10 ton
Here, Nc = 9
And CP = 4 t/m2
Ap = cross-sectional area of pile tip = 0.28 m2

Ultimate Capacity due to Skin Friction


Stratum ST - I ST - II ST - III ST - IV ST - V ST - VI ST - VII ST - VIII ST - IX ST - X
Nature Clay Sand Clay Sand Clay Sand Sand Sand Sand Sand
n
Eff D (m) 7.50 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2
As (m ) 14.14 1.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
φ (deg) 0 34 0 31 12 0 0 0 0 0
2
C (t/m ) 4.00 0.00 5.00 0.00 5.60 0.00 0.00 0.0 0.0 0.00
3
ϒ (t/m ) 1.88 1.98 1.94 1.96 1.95 0.00 0.00 0.00 0.00 0.00
2
PDi (t/m ) 4.62 8.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
K 0 1.1 0 1.0 1.0 0 0 0 0 0
**δ (deg) 0 31 0 28 9 0 0 0 0 0
α 1.00 0 0.87 0 0.78 0 0 0 0 0

S GHOSH & ASSOCIATES (P) LTD.


Unit No. EKT 5/6-OP-1, EK Tower, Plot No. IID/30, Action Area-IID, New Town, Kolkata-700161
E-mail: [email protected], [email protected]. Tele-(033)23248053
LOAD CARRYING CAPACITY OF PILES (STATIC ANALYSIS)
For Cast In Situ Bored Piles (As per IS 2911 (Part 1/Sec 2) : 2010)
(Considering GWT at EGL)
Site - Proposed Factory Shed of Bengal Beverages Pvt Ltd at Paraj, Burdwan, West Bengal
EGL (±) 0.00m Layer-wise frictional resistance developed

Stratum ST - I ST - II ST - III ST - IV ST - V ST - VI ST - VII ST - 8 ST - 9 ST - 10


n
Resis (ton) 57 10 0 0 0 0 0 0 0 0

Therefore unit skin friction


Stratum ST - I ST - II ST - III ST - IV ST - V ST - VI ST - VII ST - 8 ST - 9 ST - 10
n
Unit Resis 4.0 5.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

But as per Tomlinson recommendation, in sand unit skin friction should not exceed 11 ton/m2.
Therefore, considering Tomlinson's recommendation, stratum-wise total skin friction
Stratum ST - I ST - II ST - III ST - IV ST - V ST - VI ST - VII ST - 8 ST - 9 ST - 10
Total Skin
57 10 0 0 0 0 0 0 0 0
Friction

Hence, total skin friction developed due to the effective stratums


surrounding the pile shaft = ∑ = 67 ton

Therefore total ultimate pile capacity (Q u) = 77 ton

Therefore, Safe Load Carrying Capacity in Compression (Q s) = 31 Ton (FS = 2.5)


And, Safe Load Carrying Capacity in Tension = 22 Ton (FS = 3)

S GHOSH & ASSOCIATES (P) LTD.


Unit No. EKT 5/6-OP-1, EK Tower, Plot No. IID/30, Action Area-IID, New Town, Kolkata-700161
E-mail: [email protected], [email protected]. Tele-Fax(033)23248053