GD - Esteban Ortiz

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

LOCATION PLAN

LAMBERT COORDINATES -

+
251802.8842
X: ______________________________
230690.1025
Y: ______________________________
CATASTRO
_________________

ESTEBAN ORTIZ FLORES 327-049-348-15


LAT: 18.109660
LON: -65.944526

DESIGN SET FOR CONSTRUCTION

revisions

[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
SITE
STREET VIEW

date
SPECIALISTS:
by
no.
AEREAL VIEW

COVER PAGE
SHEET TITLE:

CARR 181 KM 11 R902 KM 5.0 LOT I BO QUEBRADA ARENAS


ACCOUNT NUMBER #3012022418
ESTEBAN ORTIZ FLORES
LUMA METER #84329571
FRONT VIEW

SAN LORENZO PR 00754


PROJECT ADDRESS:
PROJECT TITLE:
PUERTO RICO MASTER MAP
SHEET NUMBER DESCRIPTION PROPIETARY AND CONFIDENTIAL THE
PV-1.0 COVER PAGE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
PV-2.0 SITE DISTRIBUTION JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
PV-3.0 ONE LINE DIAGRAM WITHOUT THE WRITTEN CONSENT OF ENG.

PV-4.0 ITEM'S DESCRIPTION JORGE E. PEREZ, P.E. IS PROHIBITED.

PV-5.0 RACKING DETAILS


PV-6.0 LABELS YO, JORGE E. PEREZ CON LICENCIA No. 22610,
CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO
QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES DE ESTE
REGLAMENTO Y LEYES.

DRAW: DRAWING No.


JORGE E. PEREZ
Location:
SAN LORENZO, P.R. 00754
PV-1.0
Date: SHEET No.
10/23/2024
Scale:
N.T.S. 1/6
LEGEND

-
+
SOLAR MODULE
JA SOLAR 400W
AS PER DESCRIPTION ON DRAWINGS
PROP
ERTY
LIMIT FOX ESS BATERY
PER DESCRIPTION ON DRAWINGS

ALTERNATE CURRENT (AC) EXPOSED CONDUITS


RUN AS PER DESCRIPTION ON DRAWINGS
DIRECT CURRENT (DC) EXPOSED CONDUITS
RUN AS PER DESCRIPTION ON DRAWINGS

revisions
EMERGENCY SHUTDOWN DISCONNECT
AS PER DESCRIPTION ON DRAWING

MDP

[email protected]
RUN AS PER DESCRIPTION ON DRAWINGS

ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
FOX ESS INVERTER
AS PER DESCRIPTION ON DRAWING
PR O P

EXISTING LUMA METER # 84329571


ER

ACCOUNT NUMBER # 3012022418


T Y

FOX HUB
L

AS PER DESCRIPTION ON DRAWING


IM

A01
A02
IT

A03

date
A04
A05

SPECIALISTS:
by
A06
A07
AC

A08
CO UMA

no.
A09
UN M
L

A10

PRO
LU UMB R #8
T N ETE

SYSTEM SUMMARY
MA ER 43
ME #3 295
TE 012 71

P
B01
R

E
B02 MODULE MODEL JA SOLAR 400W
02

B03

R
24

B04
18

T
B05

Y
B06 MODULE STC DC RATING 400 W
B07

LIMIT

SITE DISTRIBUTION
B08
B09 (02) STRING OF 10 MODULES
B10 MODULE PER SOURCE CIRCUIT (01) STRING OF 03 MODULES
C01
C02
C03
TOTAL MODULE COUNT 23

SHEET TITLE:
37.3 V
MODULE VOC

TOTAL STC-DC SYSTEM SIZE 9.200 KW

FO
TOTAL AC PEAK OUTPUT POWER 11.400KW

XE
RA C D

SS
PID ISC
A

BA
SH N
RACKING SYSTEM MODEL UNIRAC

TT
UT NE

ER
O
DO CT

QUEBRADA ARENAS SAN LORENZO PR 00754


ACCOUNT NUMBER #3012022418
WN
INVERTER
INVERTER MODEL NO. FOX ESS H1-11-4-US

-
FO

CARR 181 KM 11 R902 KM 5.0 LOT I BO


XH

ESTEBAN ORTIZ FLORES


LUMA METER #84329571
UB
RATED OUTPUT POWER 11.400 W

FO
XE
SS
SITE LATITUDE 18°

IN
VE
RT
ER
MP1: 194°
ARRAY AZIMUTH

PROJECT ADDRESS:
PROJECT TITLE:
ROOF SLOPE / MODULE TILT MP1: 5°

CARR ESTE
BATTERY STORAGE MODEL FOX ECS SERIES

181 K BAN O
M 11 TOTAL BATTERY 1

R902 RTIZ BATTERY STORAGE KWH 12 kWh


PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS

KM 5. FLOR
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY

0 LOT ES
ASHRAE 2% DRY-BULB DESIGN TEMP. 32.2 CELSIUS REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.

LORE I BO Q ASHRAE EXTREME ANNUAL MEAN 19.5 CELSIUS


JORGE E. PEREZ, P.E. IS PROHIBITED.

NZO P UEBR
MINIMUM DRY-BULB TEMP.

R 007 ADA A INTERCONNECTION VOLTAGE 120/240 V SINGLE PHASE


YO, JORGE E. PEREZ CON LICENCIA No. 22610,
CERTIFICO QUE SOY EL PROFESIONAL QUE

54 REN DISEÑO LOS PLANOS DE ENERGIA RENOVABLE


PARA ESTE PROYECTO. TAMBIEN CERTIFICO

AS SA QUE DICHOS PLANOS CUMPLEN CON LAS


DISPOSICIONES APLICABLES DE ESTE

N SYSTEM CAPACITY: DRAW:


REGLAMENTO Y LEYES.

DRAWING No.
JORGE E. PEREZ
Location: PV-2.0
OVERALL-SITE PLAN AC SYSTEM CAPACITY: 11.400 KW SAN LORENZO, P.R. 00754
Date: SHEET No.
N.T.S. 10/23/2024
SCALE: ______________________________ DC SYSTEM CAPACITY: 9.200 KW Scale:
N.T.S. 2/6
WIRING DIAGRAM PLAN -

+
SCALE: NTS

revisions
1

[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
FOX LITHIUM
20KWH
11 9
ELECTRICAL LUMA METER #84329571
10 100A, 120/240 VAC
ACCOUNT NUMBER #3012022418
FOX INVERTER LOAD SIDE SYSTEM

date
SPECIALISTS:
12

by
FOX

no.
FOX BATTERY
120/240V P4 P5 P6
PV3-
P8
L2

P9
N

P10
L1

P11
PE

EARTH
P12
L2
N

N-BACKUP
P14
L1

P13

BAT-

PV1+

PV2+
PV1-

PV2-
+
P2 P V3
P2
P3 P7 VACANT WITH HUB
BAT
MPPT1 MPPT2 MPPT3 AC-GRID AC-BACKUP
+ - 1A+ 1A- 1B+ 1A- 2+ 2- 3+ 3- P1 P2
BAT DvDO
L2 N L1 PE L2 N L1

BAT+ P3 FOXHub
P4 PARALLEL
P5 FOXHub

P1

A10 A01
GROUND

COMMUNICATION
CABLE FOX Hub
GROUND

EXISTING GROUND ROD


15
2

ONE LINE DIAGRAM


RSD-S-PLC RSD-S-PLC RSD-S-PLC RSD-S-PLC
5
6

SHEET TITLE:
13
14
INTERCEPTED
B10 B01 17
4 7 AT METER
L1
15 L2
RSD-S-PLC RSD-S-PLC RSD-S-PLC RSD-S-PLC FOX HUB

QUEBRADA ARENAS SAN LORENZO PR 00754


ACCOUNT NUMBER #3012022418
Load 1

CARR 181 KM 11 R902 KM 5.0 LOT I BO


13
L1

ESTEBAN ORTIZ FLORES


LUMA METER #84329571
Load 1
L2

RAPID SHUTDOWN
16
Load 2
L1

14 Load 2
L2 AC DISCONNECT
Solar L1

C03 C01 Solar L2

Inverter
L1

PROJECT ADDRESS:
Inverter
L2

PROJECT TITLE:
RSD-S-PLC RSD-S-PLC RSD-S-PLC L1 L2 N
L1 L2

GRID TO GENERATOR
GENERATOR
L1 L2 L1 L2

13 BACKUP NON-BACKUP
N G
G MDP
14 PROPIETARY AND CONFIDENTIAL THE
3 EXISTING RESIDENTIAL INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
MAIN DISTRIBUTION PANEL (MDP) JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
125AMP, BUS WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.

YO, JORGE E. PEREZ CON LICENCIA No. 22610,


CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO
12V GND A1 B1 H1 L1 QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES DE ESTE
REGLAMENTO Y LEYES.

DRAW: DRAWING No.


JORGE E. PEREZ
Location: PV-3.0
SAN LORENZO, P.R. 00754
Date: SHEET No.
10/23/2024
Scale:
N.T.S. 3/6
-

+
WIRING DIAGRAM LEGEND:
1. EXISTING ELECTRICAL ENERGY METER, ACCOUNT NUMBER #3012022418, LUMA METER #84329571, 100AMP, 120/240VAC, WITH BREAKER 100AMP, 1 PHASE, CIRCUIT BREAKER. TO REMAIN.
2. AC FEEDERS: 3 # 2 THHN-2 AND 1 # 8 THHN GREEN GROUND IN A 1-1/2" DIAM. PVC SCH. 80 CONDUIT WHEN INSTALLED OUTDOOR. USE EMT CONDUIT WHEN INSIDE THE BUILDING. USE PVC SCH. 40 WHEN INSTALLED UNDERGROUND OR
EMBEDDED IN CONCRETE WALLS.
3. TWO (2) CT PRODUCTION CT'S MODEL (CT-1112477-00-A) FOX SYSTEM.
4. FOX HUB, 120/240 VAC. SUPPORTED INVERTER FOX US SERIES.

revisions
5. FOX HUB SIGNAL WIRING. DC FEEDER: 2 # 16 TO CONNECT TERMINALS 12V AND GND OF THE INVERTER TO THE FOX HUB. DC FEEDER: 4 RANGE OF # 16- # 24 TO CONNECT TERMINALS A1, B1, H1 AND L1.

[email protected]
6. AC FEEDERS: 3 # 6 THHN-2 AND 1 # 10 THHN GREEN GROUND IN A 1-1/2" DIAM. PVC SCH. 80 CONDUIT WHEN INSTALLED OUTDOOR. USE EMT CONDUIT WHEN INSIDE THE BUILDING. USE PVC SCH. 40 WHEN INSTALLED UNDERGROUND OR

ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
EMBEDDED IN CONCRETE WALLS.
7. AC FEEDER: 2 # 16 THWN-2.
8. RAPID SHUTDOWN INITIATOR DEVICE & AC DISCONNECT.
9. FOX INVERTER H1-11.4-US, SPLIT-PHASE HYBRID, 120/240 VAC. RSD TRANSMITTER IS INTEGRATED.
10. BATTERY COMMUNICATION CABLE WITH RJ45 CONNETORS.
11. DC FEEDER: 2 # 6 AWG RHH/RHW-2 FOR BATTERY CONNECTION.

date
SPECIALISTS:
12. PROPOSED ONE (1) FOX LITHIUM BATTERY 12KWH. 120/240 VAC.

by
13. DC FEEDER: 2 # 10 AWG RHH/RHW-2 AND 1 # 8 THHN-2 GREEN GROUND (G.G.) IN A 3/4" DIAM. PVC SCH.40 CONDUIT.

no.
14. RSD-S-PLC FOR RAPID SHUTDOWN EXECUTION.
15. PROPOSED SOLAR MODULE JA SOLAR 400W.
16. INSULATED ELECTRICAL POWER IN-LINE SPLICE CONNECTORS, 600V, DUAL SIDED ENTRY, FOR ALL CONDUCTORS (L1, L2, N AND G). INTERCEPTED AT METER BASE.
17. EXISTING AC FEEDER, TO REMAIN.
18. EXISTING RESIDENTIAL DISTRIBUTION PANEL (MDP).

ITEM'S DESCRIPTION
SHEET TITLE:

QUEBRADA ARENAS SAN LORENZO PR 00754


ACCOUNT NUMBER #3012022418

CARR 181 KM 11 R902 KM 5.0 LOT I BO


ESTEBAN ORTIZ FLORES
LUMA METER #84329571

PROJECT ADDRESS:
PROJECT TITLE:
PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.

YO, JORGE E. PEREZ CON LICENCIA No. 22610,


CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO
QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES DE ESTE
REGLAMENTO Y LEYES.

DRAW: DRAWING No.


JORGE E. PEREZ
Location: PV-4.0
SAN LORENZO, P.R. 00754
Date: SHEET No.
10/23/2024
Scale:
N.T.S. 4/6
-
+
revisions

[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
date
SPECIALISTS:
by
no.

RACKING DETAILS
SHEET TITLE:

QUEBRADA ARENAS SAN LORENZO PR 00754


ACCOUNT NUMBER #3012022418

CARR 181 KM 11 R902 KM 5.0 LOT I BO


ESTEBAN ORTIZ FLORES
LUMA METER #84329571

PROJECT ADDRESS:
PROJECT TITLE:
PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.

YO, JORGE E. PEREZ CON LICENCIA No. 22610,


CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO
QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES DE ESTE
REGLAMENTO Y LEYES.

DRAW: DRAWING No.


JORGE E. PEREZ
Location:
SAN LORENZO, P.R. 00754
PV-5.0
Date: SHEET No.
10/23/2024
Scale:
SC 5/6
-

+
SOLAR PV SYSTEM ! WARNING
EQUIPED WITH RAPID SHUTDOWN
! CAUTION
RAPID SHUTDOWN TURN OFF PHOTOVOLTAIC AC
SOLAR POINT OF CONNECTION RSD DISCONNECT DISCONNECT PRIOR TO

revisions
NEXT TO PV BREAKER @ SOLAR ELECTRIC WORKING INSIDE PANEL
PV PANEL
BACK-UP GATEWAY 2

[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
TRANSFER SWITCH

TURN RAPID SHUTDOWN SWITCH TO


THE "OFF" POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE SHOCK
HAZARD IN THE ARRAY

date
METER

SPECIALISTS:
by
! WARNING !

no.
WARNING: PHOTOVOLTAIC
POWER SOURCE DUAL POWER SUPPLY
SOURCE: UTILITY GRID
CONDUITS OF PV
AND PV POWER SOURCE
ELECTRIC SYSTEM
! WARNING

LABELS
SHEET TITLE:
RSD DISCONNECT / MAIN
ELECTRIC SHOCK HAZARD BREAKER METER
TERMINALS ON THE LINE AND LOAD
SIDES MAY BE ENERGIZED IN THE

QUEBRADA ARENAS SAN LORENZO PR 00754


ACCOUNT NUMBER #3012022418
OPEN POSITION

CARR 181 KM 11 R902 KM 5.0 LOT I BO


ESTEBAN ORTIZ FLORES
LUMA METER #84329571
IQ COMBINER / AC COMBINER
/RSD DISCONNECT/ MDP/
TRANSFER SWITCH

PROJECT ADDRESS:
PROJECT TITLE:
! WARNING PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS

! CAUTION THIS EQUIPMENT FED BY MULTIPLE


DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.

SOLAR CIRCUIT PHOTOVOLTAIC SYSTEM SOURCE. TOTAL RATING OF ALL JORGE E. PEREZ, P.E. IS PROHIBITED.

OVERCURRENT DEVICES,
JB OF PV ! AC DISCONNECT ! EXCLUDING MAIN SUPPLY
YO, JORGE E. PEREZ CON LICENCIA No. 22610,
CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO

RATED AC OUTPUT CURRENT A OVERCURRENT DEVICE, SHALL QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES
REGLAMENTO Y LEYES.
DE ESTE

NOMINAL OPERATING AC VOLTAGE V NOT EXCEED DRAW: DRAWING No.

AMPACITY OF BUSBAR JORGE E. PEREZ


Location:
SAN LORENZO, P.R. 00754
PV-6.0
RSD DISCONNECT Date:
10/23/2024 SHEET No.

BACK-UP GATEWAY 2 Scale:


N.T.S. 6/6