GD - Esteban Ortiz
GD - Esteban Ortiz
GD - Esteban Ortiz
LAMBERT COORDINATES -
+
251802.8842
X: ______________________________
230690.1025
Y: ______________________________
CATASTRO
_________________
revisions
[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
SITE
STREET VIEW
date
SPECIALISTS:
by
no.
AEREAL VIEW
COVER PAGE
SHEET TITLE:
-
+
SOLAR MODULE
JA SOLAR 400W
AS PER DESCRIPTION ON DRAWINGS
PROP
ERTY
LIMIT FOX ESS BATERY
PER DESCRIPTION ON DRAWINGS
revisions
EMERGENCY SHUTDOWN DISCONNECT
AS PER DESCRIPTION ON DRAWING
MDP
[email protected]
RUN AS PER DESCRIPTION ON DRAWINGS
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
FOX ESS INVERTER
AS PER DESCRIPTION ON DRAWING
PR O P
FOX HUB
L
A01
A02
IT
A03
date
A04
A05
SPECIALISTS:
by
A06
A07
AC
A08
CO UMA
no.
A09
UN M
L
A10
PRO
LU UMB R #8
T N ETE
SYSTEM SUMMARY
MA ER 43
ME #3 295
TE 012 71
P
B01
R
E
B02 MODULE MODEL JA SOLAR 400W
02
B03
R
24
B04
18
T
B05
Y
B06 MODULE STC DC RATING 400 W
B07
LIMIT
SITE DISTRIBUTION
B08
B09 (02) STRING OF 10 MODULES
B10 MODULE PER SOURCE CIRCUIT (01) STRING OF 03 MODULES
C01
C02
C03
TOTAL MODULE COUNT 23
SHEET TITLE:
37.3 V
MODULE VOC
FO
TOTAL AC PEAK OUTPUT POWER 11.400KW
XE
RA C D
SS
PID ISC
A
BA
SH N
RACKING SYSTEM MODEL UNIRAC
TT
UT NE
ER
O
DO CT
-
FO
FO
XE
SS
SITE LATITUDE 18°
IN
VE
RT
ER
MP1: 194°
ARRAY AZIMUTH
PROJECT ADDRESS:
PROJECT TITLE:
ROOF SLOPE / MODULE TILT MP1: 5°
CARR ESTE
BATTERY STORAGE MODEL FOX ECS SERIES
181 K BAN O
M 11 TOTAL BATTERY 1
KM 5. FLOR
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
0 LOT ES
ASHRAE 2% DRY-BULB DESIGN TEMP. 32.2 CELSIUS REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.
NZO P UEBR
MINIMUM DRY-BULB TEMP.
DRAWING No.
JORGE E. PEREZ
Location: PV-2.0
OVERALL-SITE PLAN AC SYSTEM CAPACITY: 11.400 KW SAN LORENZO, P.R. 00754
Date: SHEET No.
N.T.S. 10/23/2024
SCALE: ______________________________ DC SYSTEM CAPACITY: 9.200 KW Scale:
N.T.S. 2/6
WIRING DIAGRAM PLAN -
+
SCALE: NTS
revisions
1
[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
FOX LITHIUM
20KWH
11 9
ELECTRICAL LUMA METER #84329571
10 100A, 120/240 VAC
ACCOUNT NUMBER #3012022418
FOX INVERTER LOAD SIDE SYSTEM
date
SPECIALISTS:
12
by
FOX
no.
FOX BATTERY
120/240V P4 P5 P6
PV3-
P8
L2
P9
N
P10
L1
P11
PE
EARTH
P12
L2
N
N-BACKUP
P14
L1
P13
BAT-
PV1+
PV2+
PV1-
PV2-
+
P2 P V3
P2
P3 P7 VACANT WITH HUB
BAT
MPPT1 MPPT2 MPPT3 AC-GRID AC-BACKUP
+ - 1A+ 1A- 1B+ 1A- 2+ 2- 3+ 3- P1 P2
BAT DvDO
L2 N L1 PE L2 N L1
BAT+ P3 FOXHub
P4 PARALLEL
P5 FOXHub
P1
A10 A01
GROUND
COMMUNICATION
CABLE FOX Hub
GROUND
SHEET TITLE:
13
14
INTERCEPTED
B10 B01 17
4 7 AT METER
L1
15 L2
RSD-S-PLC RSD-S-PLC RSD-S-PLC RSD-S-PLC FOX HUB
RAPID SHUTDOWN
16
Load 2
L1
14 Load 2
L2 AC DISCONNECT
Solar L1
Inverter
L1
PROJECT ADDRESS:
Inverter
L2
PROJECT TITLE:
RSD-S-PLC RSD-S-PLC RSD-S-PLC L1 L2 N
L1 L2
GRID TO GENERATOR
GENERATOR
L1 L2 L1 L2
13 BACKUP NON-BACKUP
N G
G MDP
14 PROPIETARY AND CONFIDENTIAL THE
3 EXISTING RESIDENTIAL INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
MAIN DISTRIBUTION PANEL (MDP) JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
125AMP, BUS WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.
+
WIRING DIAGRAM LEGEND:
1. EXISTING ELECTRICAL ENERGY METER, ACCOUNT NUMBER #3012022418, LUMA METER #84329571, 100AMP, 120/240VAC, WITH BREAKER 100AMP, 1 PHASE, CIRCUIT BREAKER. TO REMAIN.
2. AC FEEDERS: 3 # 2 THHN-2 AND 1 # 8 THHN GREEN GROUND IN A 1-1/2" DIAM. PVC SCH. 80 CONDUIT WHEN INSTALLED OUTDOOR. USE EMT CONDUIT WHEN INSIDE THE BUILDING. USE PVC SCH. 40 WHEN INSTALLED UNDERGROUND OR
EMBEDDED IN CONCRETE WALLS.
3. TWO (2) CT PRODUCTION CT'S MODEL (CT-1112477-00-A) FOX SYSTEM.
4. FOX HUB, 120/240 VAC. SUPPORTED INVERTER FOX US SERIES.
revisions
5. FOX HUB SIGNAL WIRING. DC FEEDER: 2 # 16 TO CONNECT TERMINALS 12V AND GND OF THE INVERTER TO THE FOX HUB. DC FEEDER: 4 RANGE OF # 16- # 24 TO CONNECT TERMINALS A1, B1, H1 AND L1.
[email protected]
6. AC FEEDERS: 3 # 6 THHN-2 AND 1 # 10 THHN GREEN GROUND IN A 1-1/2" DIAM. PVC SCH. 80 CONDUIT WHEN INSTALLED OUTDOOR. USE EMT CONDUIT WHEN INSIDE THE BUILDING. USE PVC SCH. 40 WHEN INSTALLED UNDERGROUND OR
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
EMBEDDED IN CONCRETE WALLS.
7. AC FEEDER: 2 # 16 THWN-2.
8. RAPID SHUTDOWN INITIATOR DEVICE & AC DISCONNECT.
9. FOX INVERTER H1-11.4-US, SPLIT-PHASE HYBRID, 120/240 VAC. RSD TRANSMITTER IS INTEGRATED.
10. BATTERY COMMUNICATION CABLE WITH RJ45 CONNETORS.
11. DC FEEDER: 2 # 6 AWG RHH/RHW-2 FOR BATTERY CONNECTION.
date
SPECIALISTS:
12. PROPOSED ONE (1) FOX LITHIUM BATTERY 12KWH. 120/240 VAC.
by
13. DC FEEDER: 2 # 10 AWG RHH/RHW-2 AND 1 # 8 THHN-2 GREEN GROUND (G.G.) IN A 3/4" DIAM. PVC SCH.40 CONDUIT.
no.
14. RSD-S-PLC FOR RAPID SHUTDOWN EXECUTION.
15. PROPOSED SOLAR MODULE JA SOLAR 400W.
16. INSULATED ELECTRICAL POWER IN-LINE SPLICE CONNECTORS, 600V, DUAL SIDED ENTRY, FOR ALL CONDUCTORS (L1, L2, N AND G). INTERCEPTED AT METER BASE.
17. EXISTING AC FEEDER, TO REMAIN.
18. EXISTING RESIDENTIAL DISTRIBUTION PANEL (MDP).
ITEM'S DESCRIPTION
SHEET TITLE:
PROJECT ADDRESS:
PROJECT TITLE:
PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.
[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
date
SPECIALISTS:
by
no.
RACKING DETAILS
SHEET TITLE:
PROJECT ADDRESS:
PROJECT TITLE:
PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF ENG.
JORGE E. PEREZ AND POWERFY ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN CONSENT OF ENG.
JORGE E. PEREZ, P.E. IS PROHIBITED.
+
SOLAR PV SYSTEM ! WARNING
EQUIPED WITH RAPID SHUTDOWN
! CAUTION
RAPID SHUTDOWN TURN OFF PHOTOVOLTAIC AC
SOLAR POINT OF CONNECTION RSD DISCONNECT DISCONNECT PRIOR TO
revisions
NEXT TO PV BREAKER @ SOLAR ELECTRIC WORKING INSIDE PANEL
PV PANEL
BACK-UP GATEWAY 2
[email protected]
ELECTRICAL ENGINEER
LICENSE NO. 22610
JORGE E. PEREZ
TRANSFER SWITCH
date
METER
SPECIALISTS:
by
! WARNING !
no.
WARNING: PHOTOVOLTAIC
POWER SOURCE DUAL POWER SUPPLY
SOURCE: UTILITY GRID
CONDUITS OF PV
AND PV POWER SOURCE
ELECTRIC SYSTEM
! WARNING
LABELS
SHEET TITLE:
RSD DISCONNECT / MAIN
ELECTRIC SHOCK HAZARD BREAKER METER
TERMINALS ON THE LINE AND LOAD
SIDES MAY BE ENERGIZED IN THE
PROJECT ADDRESS:
PROJECT TITLE:
! WARNING PROPIETARY AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS
SOLAR CIRCUIT PHOTOVOLTAIC SYSTEM SOURCE. TOTAL RATING OF ALL JORGE E. PEREZ, P.E. IS PROHIBITED.
OVERCURRENT DEVICES,
JB OF PV ! AC DISCONNECT ! EXCLUDING MAIN SUPPLY
YO, JORGE E. PEREZ CON LICENCIA No. 22610,
CERTIFICO QUE SOY EL PROFESIONAL QUE
DISEÑO LOS PLANOS DE ENERGIA RENOVABLE
PARA ESTE PROYECTO. TAMBIEN CERTIFICO
RATED AC OUTPUT CURRENT A OVERCURRENT DEVICE, SHALL QUE DICHOS PLANOS CUMPLEN CON LAS
DISPOSICIONES APLICABLES
REGLAMENTO Y LEYES.
DE ESTE