Power System Designed To Be: The Best Quality and Low Acoustic Emissions Generators

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

.

SS
Power range 10-3000 kVA

Power system
designed to be
the Best Quality and
Low acoustic emissions
generators Super Silent

Safety First
This range offers a very
elevated modularity and
Wide Range of
a wide chice of accessories
Accessories

www.elcos.net
.SS
Power range 10-3000 kVA

Stand-by diesel Safety first. A Wide Range


gensets super Easy Maintenance. of Accessories
silenced for urban is available
areas. All operations,
like usage, to choose your
commissioning perfect suitable
and maintenance generator.
guarantee the
EU Standards operator protection
Compliant and a easy use.

Main Benefits
Reliable and Efficient Power Solutions.

ELCOS Gensets Super Silent Range covers all the most


required needs that a generator can offer.
Healthcare

The Super Silent Range offers the maximum level of


performance in case of a Main Failure occurs. These
Main Failure
Gensets grant reliable power supply and optimising
the electrical load thanks to the MC4 control panel
which allows it to adapt to the electrical supply needs.
Industry
The Super Silent Range covers the reference power
range from 10 to 3000 KVA, equipped with premium
brand engines and alternators.
Airports
These gensets can be used in a variety of applications
such as industries, homes, hotels, restaurants,
Large-Scale
hospitals, airports, shopping areas, leisure centres,
Retail Trade
military applications, telecommunications, etc.

www.elcos.net
.SS
Power range 10-3000 kVA

Super silent - Fully weatherproof


attenuated enclosure IP 32.
Soundproofed with rotproof polyester
(material class 1).

Wide openng doors


for easy maintenace.

Snap handles with key lock


offers extra safety and security.

Low fuel level Shutdown


automatic system.

Integrated fuel tank


available in different sizes.

Anti-turning forklift pockets


and forkliftable on the short side.

A C E
Central lifting lug Hot and rotating Power cable
integrated lifting Guards outlet
structure. to avoid user at the rear side.
injuries.

B D F
Direction Pipe Inspection hatch Magnetothermal
with rain cap. allows easy tank switch available
cleaning. as standard from
275 kva.
Feature

Internal residential muffler -35 dbA grants


reliable sound noise insulation.

Rainproof Control panel with key locked door.

Tamperproof panel

Air inlet plate

External oil drain point


Battery Compartment
externally accessible for easy service.

Engine and Alternators Brands

On board Panels
Polyvalent Panels And Manul Panels with sockets

10-40 KVA 50-100 KVA 130-500 KVA


.SS
Power range 10-40 kVA Technical data

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
10 kVA
11 12 10 11 3TNV76* M 3A W50° 1.8 16 GE.YA.011\010.SS 175x90x140 580 110 58
11 - 10 - 403A-11G1 M 0 W50° 2.3 16 GE.PK.011\010.SS 175x90x140 580 110 58
13 kVA
15 - 13 - 403A-15G1 M 0 W50° 2.8 25 GE.PK.016\013.SS 175x90x140 640 110 58
14 16 13 15 F2M 2011 M 2 Oil 2.6 25 GE.DZ.014\013.SS 175x90x140 690 110 59
14 16 13 15 F2L 2011 M 2 Air 2.6 25 GE.DZA.014\013.SS 175x90x140 690 110 61
15 kVA
17 19 15 17 3TNV88* M 3A W50° 2.6 25 GE.YA.017\015.SS 175x90x140 630 110 58
17 19 15 17 403A-15G2* M 0 W50° 3 25 GE.PK.017\015.SS 175x90x140 640 110 58
20 kVA
22 25 20 23 4TNV88* M 3A W50° 4 32 GE.YA.022\020.SS 175x90x140 660 110 59
21 27* 20 24 404D-22G* M 3A W50° 4 32 GE.PK.021\020.SS 175x90x140 730 110 60
21 - 20 - 404A-22G1 M 0 W50° 4 32 GE.PK.022\020.SS 175x90x140 730 110 60
22 25.3 21 24 F3M 2011 M 2 Oil 4.1 32 GE.DZ.021\020.SS 175x90x140 740 110 60
22 25.3 21 24 F3L 2011 M 2 Air 4.1 32 GE.DZA.021\020.SS 175x90x140 740 110 61
25 kVA
66 - 60 - X2.5G2 M 0 W50° 4.8 40 GE.CU.030\027.SS 190x90x150 820 250 63
30 kVA
33 38 30 35 4TNV98* M 3A W50° 5.2 50 GE.YA.037\033.SS 190x90x150 840 110 63
33 38 30 36* 1103A-33G* M/E* 0 W50° 5.4 50 GE.PK.034\031.SS 190x90x150 900 110 64
33 - 30 - X3.3G1 M 0 W50° 6.1 50 GE.CU.040\035.SS 190x90x150 890 250 64
35 37.5 30 35.7 F4M 2011* M 2 Oil 5.6 50 GE.DZ.035\030.SS 190x90x150 850 110 63
32 37.5 30 35.7 F4L 2011 M 2 Air 5.6 50 GE.DZA.035\030.SS 190x90x150 850 110 64
40 kVA
44 49 40 46 4TNV98T* M 2 W50° 7 63 GE.YA.047\044.SS 190x90x150 890 110 63
44 - 40 - S3.8G4 M 0 W50° 7.6 63 GE.CU.044\040.SS 220x110x165 1020 110 64
44 50 40 48 BF4M 2011* M 2 Oil 6.4 63 GE.DZ.044\040.SS 190x90x150 945 110 64
42 50 40 48 BF4L 2011 M 2 Air 6.4 63 GE.DZA.044\040.SS 190x90x150 945 110 64
47 - 44 - YC4FA70L-D20 E 2 W50° 8.8 63 GE.YU.050\045.SS 220x110x165 1160 250 65
* For operating at 60 Hz, check the internal code of the engine when ordering.
.SS
Power range 50-100 kVA Technical data

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
50 kVA
54 60 45 72 1103A-33TG1 M 0 W50° 8,2 80 GE.PK.051\046.SS 220x110x165 1070 250 65
- - 50 72 N45AM2 M 0 W50° 9,8 80 GE.AI.056\051. SS 220x110x165 1220 250 65
56 63 50 79 S3.8G6 M 0 W50° 9,5 80 GE.CU.055\050.SS 220x110x165 1250 250 65
54 57 47 72 F4L 914 M 0 Air 7,8 80 GE.DZA.050\047.SS 220x110x165 945 250 64
- - 51 81 YC4D85Z-D20 E 2 W50° 10,7 80 GE.YU.056\051.SS 260x110x168 1309 250 65
60 kVA
66 75 60 69 1103A-33TG2 M 0 W50° 10,4 100 GE.PK.067\061.SS 220x110x165 1220 250 65
66 73 60 66 N45SM1A M 2 W50° 10,2 100 GE.AI.066\060.SS 220x110x165 1305 250 65
66 - 61 - S3.8G7 M 0 W50° 11 100 GE.CU.066\060.SS 260x110x168 1280 250 66
63 74 62 66 BF4M 2011C M 2 Oil 8,7 100 GE.DZ.066\060.SS 220x110x165 1220 250 67
65 74 60 66 F6L 912 M 0 Air 8,7 100 GE.DZA.066\060.SS 220x110x165 1220 250 68
66 - 60 - YC4D90Z-D21 E 2 W50° 11,7 100 GE.YU.066\060.SS 260x110x168 1200 250 67
80 kVA
88 100 80 90 1104A-44TG2 M 0 W50° 14 125 GE.PK.088\080.SS 260x110x168 1450 250 66
95 97 85 86 TAD 530 GE M 2 W50° 13 125 GE.VO.094\085. SS 260x110x168 1525 250 66
90 99 80 90 N45SM3 M 0 W50° 15,4 125 GE.AI.090\80.SS 260x110x168 1400 250 67
81 92 76 81 BF4M 2012 C M 2 W50° 11,8 125 GE.DZ.080\07580.SS 260x110x168 1460 250 67
77 89 73 85 F6L 914 M 0 Air 11,6 125 GE.DZA.080\073.SS 260x110x168 1520 250 67
88 - 80 - YC4A110Z-D20 E 2 W50° 13,9 125 GE.YU.088\080.SS 260x110x168 1500 250 67
100 kVA
110 125 100 112 1104C-44TAG2 E 2 W50° 17,1 160 GE.PK.110\100.SS 260x110x168 1580 250 67
115 115 105 103 TAD 531 GE M 2 W50° 16 160 GE.VO.115\105.SS 320x120x190 1890 400 65
110 121 100 110 N45TM2A M 2 W50° 16,2 160 GE.AI.110\100.SS 260x110x168 1580 250 67
110 - 100 - 6BTA5.9G5 E 0 W50° 18 160 GE.CU.110\105.SS 320x120x190 1760 400 67
108 117 102 112 BF4M1013EC M 2 W50° 18,4 160 GE.DZ.110\105.SS 320x120x190 1820 400 66
105 112 100 107 BF6L 914 M 2 Air 11,8 160 GE.DZA.110\100.SS 260x110x168 1520 250 67
110 - 100 - YC4A140L-D20 E 2 W50° 16,9 160 GE.YU.110\100.SS 260x110x168 1730 250 67
* For operating at 60 Hz, check the internal code of the engine when ordering.
.SS
Power range 130-250 kVA Technical data

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
130 kVA
150 169 135 152 1106A-70TG1 M 0 W50° 24,1 250 GE.PK.151\137.SS 320x120x190 1830 400 67
144 151 130 135 TAD 532 GE E 2 W50° 20,9 250 GE.VO.150\135.SS 320x120x190 1970 400 66
135 140 120 130 N45TM3 M 0 W50° 21 250 GE.AI.131\120.SS 320x120x190 1850 400 66
150 170 136 150 6BTAA5.9G6 E 0 W50° 26 250 GE.CU.150\135.SS 360x122x205 1900 450 68
130 132 120 120 BF4M1013FC M 2 W50° 25 250 GE.DZ.130\120.SS 320x120x190 1780 400 67
150 - 135 - YC6B190L-D20 E 2 W50° 20,8 250 GE.YU.150\135.SS 360x122x205 2150 450 67
150 kVA
165 188* 150 169* 1106A-70TAG2* M 0 W50° 24,7 250 GE.PK.166\150.SS 360x122x205 2100 450 67
165 172 150 155 TAD 731 GE M 2 W50° 25,1 250 GE.VO.165\150.SS 360x122x205 2370 450 67
176 187 165 170 N67TM4 M 0 W50° 29 250 GE.AI.176\165.SS 320x120x190 2070 400 68
170 - 155 - 6BTAA5.9G7 E 0 W50° 29 250 GE.CU.176\160.SS 360x122x205 1950 450 68
162 180 150 171 BF6M1013EC M 2 W50° 27,4 250 GE.DZ.160\150.SS 360x122x205 2300 450 67
170 200 150 185 DP086TA E 1 W43° 25,5 250 GE.DW.170\150.SS 320x120x190 450 68
165 - 150 - YC6B205L-D20 E 2 W50° 25,1 250 GE.YU.165\150.SS 360x122x205 2290 450 68
180 kVA
205 227 185 203 TAD 732 GE E 2 W50° 30 400 GE.VO.205\185.SS 360x122x205 2550 450 68
200 kVA
220 - 200 - 1106A-70TAG4 E 0 W50° 34,7 400 GE.PK.220\200.SS 360x122x205 2490 450 68
225 252 205 226 TAD 733 GE E 2 W50° 33 400 GE.VO.225\205.SS 360x122x205 2500 450 68
220 234 200 210 N67TM7 M 0 W50° 37,3 400 GE.AI.221\201.SS 360x122x205 2475 450 68
220 248 200 225 QSB7 G5 E 3A W50° 36 400 GE.CU3A.225\200.SSS 360x122x205 2475 450 68
226 250 205 220 BF6M 1013FCG3 E 2 W50° 34,6 400 GE.DZ.225\205.SS 360x122x205 2190 450 67
225 250 200 230 P086TI E 2 W43° 31,7 400 GE.DW.220\200.SS 360x122x205 2550 450 68
220 - 200 - YC6G270L-D20 E 2 W50° 32,3 400 GE.YU.220\200.SS 360x122x205 2550 450 68
250 kVA
320 - 250 290 1506A-E88TAG3 E 0 W50° 41,6 400 GE.PK.275\250.SS 360x122x205 2640 450 68
287 287 250 255 TAD 734 GE E 2 W50° 40,9 400 GE.VO.275\250. SS 360x122x205 2750 450 68
290 285 250 260 N67 TE8W E 0 W50° 38,8 400 GE.AI.275\250.SS 360x122x205 450 69
300 300 250 260 TCD 2013 L06 4V E 2 W50° 40,1 400 GE.DZ.275\250.SS 360x122x205 2390 450 68
285 285 230 250 DP086LA E 2 W43° 36,8 400 GE.DW.250\230.SS 360x122x205 2400 450 69
- - 250 - YC6MK350L-D20 E 2 W50° 43 400 GE.YU.275\250.SS 410x150x230 3325 600 68

* For operating at 60 Hz, check the internal code of the engine when ordering.
The speed ​​governor can be Mechanical or Electronic, depending on the frequency of the engine chosen.
.SS
Power range 275-400 kVA Technical data

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
275 kVA
300 335 275 316 P126TI E 2 W43° 43.6 630 GE.DW.300\275.SS 410x150x230 3430 600 70
300 kVA
335 389 300 352 1506A-E88TAG5 E 0 W50° 48 630 GE.PK.335\300.SS 410x150x230 3160 600 69
350 360 320 340 TAD 1341 GE E 2 W50° 43 630 GE.VO.360\325.SS 410x150x230 3850 600 67
332 363 305 330 C87TE4 E 0 W50° 52 630 GE.AI.332\305.SS 410x150x230 3260 600 69
330 375 300 344 QSL9G5 E 0 W50° 46 630 GE.CU.346\301.SS 410x150x230 3010 600 69
350 374 315 338 BF6M 1015 C G1 E 2 W50° 46,6 630 GE.DZ.350\315.SS 410x150x230 3610 600 68
330 - 300 - YC6MK410L-D20 E 2 W50° 52,2 630 GE.YU.330\300.SS 410x150x230 3640 600 70
335 390 300 345 P126 TI-II E 1 W43° 47 630 GE.DW.340\310.SS 410x150x230 3550 600 69
350 kVA
400 440 350 400 2206A-E13TAG2 E 0 W50° 54 630 GE.PK.400\350.SS 410x150x230 4190 600 69
375 438 350 401 TAD 1342 GE E 2 W50° 51 630 GE.VO.375\350.SS 410x150x230 3690 600 68
385 418 350 380 C13TE2A E 2 W50° 56 630 GE.AI.385\350.SS 410x150x230 3870 600 69
390 - 350 - BF6M 1015 C G2 E 2 W50° 52,5 630 GE.DZ.390\350.SS 470x180x250 3880 1150 69
405 445 365 400 DP126LB E 0 W43° 57,1 630 GE.DW.400\365.SS 470x180x250 4090 1150 70
375 kVA
410 451 375 410 TAD 1343 GE E 2 W50° 54,7 630 GE.VO.410\375.SS 410x150x230 3760 600 68
412 426 380 387 BF6M 1015CP E 2 W50° 59,4 630 GE.DZ.410\380.SS 470x180x250 3980 1150 69
400 kVA
440 440 400 400 2206A-E13TAG3 E 0 W50° 62 630 GE.PK.450\400.SS 415x150x230 4100 600 69
450 501 410 456 TAD 1344 GE E 2 W50° 60,8 630 GE.VO.450\410.SS 410x150x230 4000 600 68
440 462 400 420 C13TE3A E 2 W50° 62 630 GE.AI.440\400.SS 410x150x230 4080 600 69
470 510 410 445 P158 LE E 1 W43° 65,1 630 GE.DW.460\420.SS 470x180x250 4270 1150 71

* For operating at 60 Hz, check the internal code of the engine when ordering.
The speed governor
​​ can be Mechanical or Electronic, depending on the frequency of the engine chosen.
.SS
Power range 450-650 kVA

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
450 kVA
500 550 455 500 2506C-E15TAG1 E 2 W50° 73 800 GE.PK.500\450.SS 470x180x250 5370 1150 70
500 501 450 456 TAD 1345 GE E 2 W50° 66,7 800 GE.VO.500\450.SS 410x150x230 4850 900 71
500 550 450 475 C13TE6W E 0 W50° 80,2 800 GE.AI.500\450.SS 470x180x250 4850 1150 71
480 512 450 464 BF8M 1015CG1 E 2 W50° 68,1 800 GE.DZ.480\450.SS 470x180x250 4970 1150 71
10V 1600 G10F
500 550 450 500 (10V 1600 G10S) E 3A W50° 72,8 800 GE.MT.500\450.SS 470x180x250 5360 1150 70
510 570 450 520 DP158 LCF E 0 W43° 72,9 800 GE.DW.500\460.SS 470x180x250 5290 1150 72
(DP158LCS)
500 - 455 - YC6T600L-D22 E 2 W50° 73,2 800 GE.YU.500\455.SS 470x180x250 5630 1150 72
500 kVA
550 550 500 500 2506C-E15TAG2 E 2 W50° 81 800 GE.PK.550\500.SS 470x180x250 5280 1150 72
550 645 500 573 TAD 1641 GE E 2 W50° 73,5 800 GE.VO.550\500.SS 470x180x250 5140 1150 70
550 605 500 550 C13TE7W E 0 W50° 80,2 800 GE.AI.550\500.SS 470x180x250 5140 1150 70
550 500 500 450 QSX15G8 E 2 W50° 79 800 GE.CU.550\500.SS 470x180x250 5270 1150 70
560 588 510 536 BF8M 1015CP E 2 W50° 81,7 800 GE.DZ.560\510.SS 470x180x250 5270 1150 71
550 630 500 575 10V 1600 G20F E 3A W50° 77 800 GE.MT.550\500.SS 470x180x250 5510 1150 71
(10V 1600 G20S)
580 652 530 568 DP158 LDF E 0 W43° 83,4 800 GE.DW.580\520.SS 470x180x250 5430 1150 72
(DP158LDS)
550 - 500 - YC6T660L-D20 E 2 W50° 80 800 GE.YU.550\500.SS 470x180x250 5640 1150 72
550 kVA
625 690 570 625 TAD 1642 GE E 2 W50° 83,3 1000 GE.VO.630\570.SS 470x180x250 5610 1150 70
DP180LAF
630 694 570 629 (DP180LAS)
E 0 W43° 94,2 1000 GE.DW.625\560.SS 470x180x250 5690 1150 72
600 kVA
660 680 600 625 2806A-E18TAG1A E 0 W50° 90 1000 GE.PK.660\600.SS 470x180x250 5920 1150 72
650 690 596 625 TAD 1642 GE E 2 W50° 83,3 1000 GE.VO.650\596.SS 470x180x250 5610 1150 70
660 761 600 685 TWD 1652 GE E 2 W50° 91,6 1000 GE.VO.660\600.SS 470x180x250 5920 1150 70
650 690 600 630 12V 1600 G10F E 3A W50° 90,9 1000 GE.MT.650\600.SS 470x180x250 5780 1150 70
(12V 1600 G10S)
617 700 595 630 C16TE1W E 0 W50° 93 1000 GE.AI.620\600.SS 470x180x250 5920 1150 72
710 748 640 678 DP180LBF E 0 W43° 103,8 1000 GE.DW.705\633.SS 470x180x250 5820 1150 72
(DP180LBS)
650 kVA
715 715 650 650 2806A-E18TAG2 E 0 W50° 97 1000 GE.PK 715/650.SS 470x180x250 6200 1150 71
715 - 650 - TWD 1653 GE E 2 W50° 91,6 1000 GE.VO.715\650.SS 470x180x250 5920 1150 72
700 750 650 680 12V 1600 G20F E 3A W50° 99 1000 GE.MT.700\650.SS 470x180x250 5950 1150 70
(12V 1600 G20S)
750 880 680 800 DP222LBF E 0 W43° 109,2 1000 GE.DW.760\680.SS 470x180x250 5850 1150 72
(DP222LCS)
* For operating at 60 Hz, check the internal code of the engine when ordering.
The speed governor
​​ can be Mechanical or Electronic, depending on the frequency of the engine chosen.
.SS
Power range 700-1000 kVA

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Reference Power

Cooling
Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
700 kVA
TWD 1645 GE 2 W50° 91,6 1000 GE.VO.770\700.SS 470x180x250 5920 1150
770 761 700 685 E 74

800 930 750 855 DP222 LCF E 0 W43° 119,1 1250 GE.DW.830\740.SS 470x180x250 6100 1150 74
(DP222LCS)
800 kVA
880 940* 800 845* 4006-23TAG3A* E 0 W50° 130 1250 GE.PK 880\800.SS 570x225x262 8620 900 73

886 1000 805 910 QSK23G3 E 0 W40° 121 1250 GE.CU.890\800.SS 570x225x262 7460 900 72

865 - 783 - 12V 2000 G65 E 0 W40° 123 1250 GE.MT.870\780.SS 570x225x262 7700 900 72
(12V 2000 G85)
900 kVA
1029 1132 935 1029 QST30G3 E 0 W40° 139 1600 GE.CU.1030\940.SS 650x240x282 9800 1000 75
1005 1137 910 1025 16V 2000 G16F E 0 W40° 140 1600 GE.MT.1000\910.SS 650x240x282 10180 1000 75

1000 kVA
4008-TAG2A E 0 W40° 163 1600 GE.PK 1130\1000.SS 650x240x282 11080 1000
1124 1125 1022 1000 (4008-TAG2) 76

1250 - 1130 - 4008 30TAG3 E 0 W50° 188 2000 GE.PK 1250/1125.SS 650x240x282 11080 1000 74

1100 1256 1000 1146 QST30G4 E 0 W40° 151 1600 GE.CU.1100\1000.SS 650x240x282 9980 1000 72

1100 - 1000 - KTA38G5 E 0 W40° 161 1600 GE.CU.1101\1001.SS 650x240x282 11300 1000 73

1106 1250 1005 1135 16V 2000 G26F E 0 W40° 152 1600 GE.MT.1100\1000.SS 650x240x282 10380 1000 70

1254 1462 1135 1337 16V 2000 G36F E 0 W40° 174,4 2000 GE.MT.1260\1140.SS 650x240x282 11400 1000 71

* For operating at 60 Hz, check the internal code of the engine when ordering.
The speed governor
​​ can be Mechanical or Electronic, depending on the frequency of the engine chosen.
.SS
Power range 1250-3000 kVA Technical data

Power Engine GS Model Data

Nominal Current
Consumption

Dimensions

Noise level
(LexWixH)
Switch 4P
LTP PRP

@ 3/4 load

Fuel Tank
Emissions

capacity
governor

Weight

@ 7 mt
Cooling
Reference Power

Standby power Prime power

Speed
Manufacturer

kVA kVA Model Type Stage Lt A Code CM KG LT dB(A)


50 Hz 60 Hz 50 Hz 60 Hz
1250 kVA
1378 1378* 1253 1253* 4012-46TWG2A* E 0 W40° 196 2000 GE.PK 1380\1250.SS 720x240x310 14400 1000 na
1386 1610 1260 1418 KTA50G3 E 0 W40° 199 2000 GE.CU.1390\1260.SS 720x240x310 11750 1000 na
1370 1378* 1250 1253* 18V 2000 G26F E 0 W40° 196 2000 GE.MT.1370\1250.SS 720x240x310 13600 1000 na
1390 1550 1280 1400 S12R-PTA E 0 W40° 201,6 2000 GE.MH.1390\1260.SS 720x240x310 12900 1000 na
1400 kVA
1500 1500* 1364 1364* 4012-46TWG3A* E 0 W40° 213 2000 GE.PK 1500\1370.SS 720x240x310 12300 1000 na
1540 - 1400 - KTA50G8 E 0 W40° 222 2000 GE.CU.1540\1400.SS 720x240x310 12600 1000 na
1520 - 1400 - 12V 4000 G23R E 0 W40° 210 2000 GE.MT.1520\1400.SS 720x240x310 13900 1000 na
1520 1740 1380 1591 S12R-PTA2 E 0 W40° 212 2000 GE.MH.1540\1400.SS 720x240x310 13400 1000 na
1500 kVA
1656 1656* 1505 1505* 4012-46TWG4A* E 0 W40° 237 2500 GE.PK 1660\1500.SS 800x240x310 13900 1000 na
1690 - 1540 - QSK50G4 E 0 W40° 258 2500 GE.CU.1690\1540.SS 800x240x310 14400 1000 na
1650 1920 1510 1762 S12R-PTAA2 E 0 W40° 230 2500 GE.MH.1690\1540.SS 800x240x310 14400 1000 na
1700 kVA
1876 1876* 1705 1705* 4012-46TAG3A* E 0 W40° 275 2500 GE.PK 1880\1700.SS 800x240x310 16000 1000 na
12V 4000 G23
1815 1875 1650 1700 (12V 4000 G43)
E 0 W40° 241 2500 GE.MT.1820\1650.SS 800x240x310 15900 1000 na
1900 2000 1730 1880 S16R-PTA E 0 W40° 259 2500 GE.MH.1900\1730.SS 800x240x310 15300 1000 na
1900 kVA
2028 - 1844 - 4016-61TRG1 E 0 W50° 300 3200 GE.PK 2030\1850.SS 940x240x310 - 1000 na
2079 - 1890 - QSK60G3 E 0 W40° 270 3200 GE.CU.2080\1890.SS 940x240x310 - 1000 na
2035 2200 1850 2000 12V 4000 G63 E 0 W40° 266 3200 GE.MT.2040\1850.SS 940x240x310 - 1000 na
(12V 4000 G83)
2000 kVA
2250 - 2000 - 4016-61TRG2 E 0 W40° 318 3200 GE.PK .2265\2060.SS 940x240x310 - 1000 na
2237 - 2034 - QSK60G4 E 0 W40° 307 3200 GE.CU.2240\2040.SS 940x240x310 - 1000 na
2300 2500 2100 2275 16V 4000 G23 E 0 W40° 306 3200 GE.MT.2300\2100.SS 940x240x310 - 1000 na
(16V 4000 G43)
2200 2380 2000 2108 S16R-PTA2 E 0 W40° 306,9 3200 GE.MH.2200\2000.SS 940x240x310 - 1000 na
3000 kVA
2500 - 2250 - 4016-61TRG3 E 0 W40° 346 4000 GE.PK.2500\2250.SS 940x240x310 - 1000 na
2500 - 2280 - S16R2-PTAW E 0 W40° 346 4000 GE.MH.2500\2280.SS 940x240x310 - 1000 na
2530 2750 2300 2500 16V 4000 G63 E 0 W40° 330 4000 GE.MT.2530\2300.SS 940x240x310 - 1000 na
(16V 4000 G83)
2640 - 2400 - S16R2-PTAW-E E 0 W40° 346 4000 GE.MH.2640\2400.SS 1030x240x310 - 1000 na
2805 3125 2550 2813 20V 4000 G23 E 0 W40° 385 4000 GE.MT.2800\2550.SS 1030x240x310 - 1000 na
(20V 4000 G43)
3000 - 2750 - QSK78G9 E 0 W40° 406 4000 GE.CU.3000\2750.SS 1030x240x310 - 1000 na
3080 3438 2800 3125 20V 4000 G63 E 0 W40° 420 4000 GE.MT.3000\2800.SS 1030x240x310 - 1000 na
(20V 4000 G83)
3355 3750 3050 3450 20V 4000 G63L E 0 W40° 445 5000 GE.MT.3360\3000.SS 1030x240x310 - 1000 na
(20V 4000 G83L)
* For operating at 60 Hz, check the internal code of the engine when ordering.
The speed ​​governor can be Mechanical or Electronic, depending on the frequency of the engine chosen.
Panels on board

Panel on board & Variants 10-40 kVA


QLE Polyvalent panel with integrated switching
WITH ATS
Variant +010 managed by MC2 Control module

QLE Polyvalent panel without integrated switching


WITHOUT ATS
Variant +011 managed by MC2 Control module

QMC-01
Manual panel with sockets
MANUAL PANEL
Variant +012 equipped with SM1 Control module

10 -15 kVA n.1 CE 3P 16A 230V / n.1 CE 4P 16A 400V / n.1 CE 5P 16A 400V
Sockets 20 kVA n.1 CE 3P 16A 230V / n.1 CE 4P 16A 400V / n.1 CE 5P 32A 400V
25-40 kVA n.1 CE 3P 16A 230V / n.1 CE 4P 16A 400V / n.1 CE 5P 32A 400V / n.1 CE 5P 63A 400V

Panel on board & Variants 50-100 kVA


QPE Polyvalent panel with integrated switching
WITH ATS
Variant +010 managed by MC4#EVO Control module

QPE Polyvalent panel without integrated switching


WITHOUT ATS
Variant +011 managed by MC4#EVO Control module

QMC-01
Manual panel with sockets
MANUAL PANEL
Variant +012 equipped with SM1 Control module

QP.APM Parallel panel with 4P Motorized switch on board,


FOR GS PARALLELING
Variant +014 managed by DSE 8610 Control module

Panel on board & Variants 130-3000 kVA

QPE Polyvalent panel with integrated switching


WITH ATS
Variant +010 managed by MC4#EVO Control module

QPE Polyvalent panel without integrated switching


WITHOUT ATS
Variant +011 managed by MC4#EVO Control module

QP.APM Parallel panel with 4P Motorized switch on board,


FOR GS PARALLELING
Variant +014 managed by DSE 8610 Control module
.SS
Power range 10-3000 kVA Optional

Canopy Connection and protection panel


High resistance painting for corrosive environments Canopy internal LED lighting system
Customized colour painting and special paint treatments High efficiency battery
5 additional sockets for socket module
Engine DSE or Comap Control module
Siren and generator status lights kit
Fuel filter Water separator Automatic double-battery system from 50kVA to 500kVA unit
It protects the GS from contaminated fuel and it prolongs system life.
GSM remote monitoring modem
LED lighting installed in the terminal box compartment
Heavy duty air cleaner
heavy duty engine air intake filtration. 50 / 60Hz selector with voltage regulation potentiometer
They are designed for high dust environments with excessive (only possible on engines with electronic governor)
vibration and extreme temperatures. Radio remote control with start and stop button
On-off device on load power demand
Alternator Differential relay management through external relay
Total power withdrawal terminal box (only for 15 to 40 kVA)
Generator with simultaneous multi-voltage 110/230/400. Grounding points

Fuel Supply The Oversize big tank


The Oversize big tank is integrated on the base. The capacity of this tank is 600 or 2000 liters.
is integrated on the base. The capacity of this tank is 600 or 2000 liters.

Automatici refilling System with Automatic Valve


Automatici refilling System with Automatic Valve
The automatic refilling system is composed by a solenoid valve mounted on
The automatic refilling system is composed by a solenoid valve mounted on
the genset fuel tank and connected to an external bulk tank. The man-
the genset fuel tank and connected to an external bulk tank. The man-
agement of the solenoid is entrusted to the control panel on board which
agement of the solenoid is entrusted to the control panel on board which
controls the opening and closing of the same, based on the minimum and
controls the opening and closing of the same, based on the minimum and
maximum set level.
Automatic transfer Switches

From 40to 4000 kVA (400V)


The QC panel is combined with the automatic control panel QPE or QLE on board.
It allows the switching of power from the mains supply line to the genset line and vice versa.
It is made of carpentry steel sheet, painted with high-strength epoxy powder.
Change-over switch: 4P Contactors or Motorized change-over switch 4P.

Double wall Fuel Tanks with bunded base and roof Double wall fuel Tanks Single wall fuel Tanks
Single wall fuel Tanks with tear Valve Model Capacity (Lt) Model Capacity (Lt)
O.C-DP-01 1.000 O.C-MP-01,5 1.500
From 1000 to 20.000 lts O.C-DP-01,5 1.500 O.C-MP-02 2.000
• Folded sheet steel O.C-DP-02 2.000 O.C-MP-03 3.000
• Anticorrosive coating with zinc phosphate O.C-DP-03 3.000 O.C-MP-05 5.000
• Epoxy-tar coating O.C-DP-04 4.000 O.C-MP-07 7.000
• Welded metal eyebolts for lifting O.C-DP-05 5.000 O.C-MP-09 9.000
• Roof in folded sheet steel with support structure (only single wall tank) O.C-DP-06 6.000

• Bunded base, 50% of the tank volume (only single wall tank) O.C-DP-08 8.000
O.C-DP-10 10.000
• Cover in checker plate
O.C-DP-12 12.000
• Hatch with bolted flange and gasket
O.C-DP-15 15.000
• Fuel refilling point
O.C-DP-20 20.000
• Threaded connections for suction pipe, return and overflow

Automatic Fuel Refilling Systems Additional tanks with bunded Automatic fuel refilling
base on trestle systems
From 120 to 500 lts Model Capacity Lt Model Description
• Analog fuel level gauge O.G-SC-120 120 O.G-ST-CA.120 120 lt
• Electromagnetic gauge at one contact O.G-SC-350 350 O.G-ST-CA.500 500 lt
• Overflow sensor O.G-SC-500 500 O.G-KDP-SDT Back-up pump
• Panel for the management of the automatic fuel refilling of the tank O.G-SC-1000 1.000 O.G-ST-EP-02 High prevalence pump 35 mt
• Manual pump with lever
• Electric pump for fuel refilling
• Fuel solenoid normally closed
• Visual flow indicator
• 3-way ball valve
BASE FRAME GENSETS CONTAINERS HIGH RENTAL GENSETS

See Also
Elcos develops, produces, sells and installs systems for the generation of electric energy from 1 to 3000 kVA standard and customized solutions.

www.elcos.net [email protected]
+39.0372.7233300
elcos.net/service

ELCOS SRL
Strada Statale 234 Km 58.250 -
26023 Grumello Cremonese CR - Italy
tel +39 0372 72330 - fax +39 0372 7233220
www.elcos.net - [email protected]
[email protected] PI 01084730199