0% found this document useful (0 votes)
14 views32 pages

VB-Cata Eng

Uploaded by

DeeFfrenT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views32 pages

VB-Cata Eng

Uploaded by

DeeFfrenT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

A Remarkable Product Must Be "Consumer Inside"

The market demands are the starting point of all products; To create a good
product should keep the demands in mind.
Based on the idea of "meet the future market demands", VIGOR in order to satisfy the market needs, from
the visible, audible and imaginable customer request, by way of the professionally R & D working group to
develop this VB Series Programmable Controller. VIGOR's expertise is more than the technical knowledge,
we also have the excellently complete product lines, which are correspond with the requires of real opera-
tions and market demands.
The VB Series PLC not only provides the feature of new generation compact size high performance PLC,
but also offers innovation design close to the market, which will provide a satisfied control for diversified
requires.
The VB Series Programmable Controller is following the concept of "Consumer Inside", we expecting your
appreciation and affirmation.

Patented Functions, Increasing Your Product Value


The state-of-the-art Multi-Functional Display will effectively enhance product
added value.
Any machine may have potential breakdown problems. When a trouble occurs, the machine designers
would like to provide the note of problem for machine operators properly then it can help the trouble-shoot-
er to solve the problem and reduce losses. But due to the limited budget, this important function is always
omitted and discarded.
Now, the VB Series PLC penetrates this requirement. At the PLC main unit, we cleverly install a LED
Multi-Functional Display, which allows users to show the machinery operation status and error messages
easily and clearly.
Furthermore, the Multi-Functional Display can be used for demonstrate text messages and graphics. Also,
when it cooperates with some input buttons, which becomes the display interface of data access unit.
Such a pleasant function have already obtained a patent license. It is an advantaged tool for enhancing
product added value and competitiveness. And, this perfect ideal will not increase any additional costs.
System Composition...................................4
The VB Series Main Unit.............................5
Features........................................................6
Attentively Innovative Design, Multi-Functional Display.............................7
Performance Specification...........................8
Effectively Reducing Labor Costs Instruction Tables........................................9
The barrier style wire terminal is strong and reliable which seems to be Regulation Specifications..........................10
the common type that for commercial PLC. But people are concerned Power Specification...................................10
about the assembly line which is always spend too much time and make Notes for Expansions.................................10
Input Point Specification...........................11
mistakes easily, as well as it has difficulties in the maintenance.
Output Point Specification.........................11
VIGOR has found such demands, the VB Series PLC delivers a solu-
Formation of Communication System...12
tion, it come up with a series of connector units. The Main Unit,
Communication Expansion Card................13
Expansion Unit and Expansion Module of the VB series come in 2 VB-CADP Dual-Ports Communication
types: the barrier terminal and ATX connector, to satisfy various Expansion Module................................14
requirements and ideas. VB-485A RS-485 Communication
For avoiding any trouble at making the connecting wires, all the con- Expansion Module....................................15
nector-type VB Series PLCs come with ATX connectors and 2-meter VB-1COM Serial Link Communication
wires. Module................................................15
The "fast linkage" characteristic of the connector-type PLC units will Communication Operation Mode.............16
efficiently reduce wiring labor, assembling duration and mistakes; Computer Link............................................16
moreover, it has the advantage of easy maintenance. Particularly for Easy Link....................................................16
machines in the mass-production industry, this efficiency stands out sig- Parallel Link............................................17
CPU Link............................................17
nificantly.
MODBUS Communication..........................18
MODEM Communication..........................18
MODEM Dialing.......................................18
Non Protocol Communication.....................19
Special Module.......................................20
VB-2VC 2-Channel value controls...............20
VB-2DA 2-Channel 12-bit Analog Output
Module....................................................20
VB-4DA 4-Channel 8-bit Analog Output
Module....................................................20
VB-4AD 4-Channel 12-bit Analog Input
Module....................................................21
VB-6A/VB-3A Analog Input/Output
Module.....................................................21
VB-8T/VB-4T Temperature Input
Module.....................................................22
VB-4PT/VB-2PT Temperature Input
Module.....................................................22
VB-2LC/VB-1LC Temperature Control
Module.....................................................23
VB-1PG Single Axis Pulse Output
Positioning Control Module.....................24
VB-1HC High Speed Counter Module.......24
Accessories ....................................... 25
VB-PWR Power Expansion Module..........25
The "fast linkage" connector has the
VB-30PS Power Supply Module..............25
advantages of easier set-up and DAP-100 Configuration Panel..................25
Input Connecting Wire mintenance.
Memory Slot Expansion Cards..................25
Connecting Cables.....................................26
Dimensions and Terminal Layouts ..... 27
94mm Model.............................................27
48mm Model............................................28
Programming Tool.....................................29
MS Windows®-based Programming Tool :
Ladder Master..........................................30
Output Connecting Wire Palm OSTM-based PDA Programming Tool :
NeoTouch.................................................30
VB Series Product List..............................31
System Composition

Programming Tool RTC/Memory Expansion Unit


Expansion Cards
MS Windows® based
Programming Tool VB-32E - 16-point Input
Ladder Master 16-point Output
VB-32XY 16-point Input
RTC Expansion Card
16-point Output
VB-RTC
VB-32XY is the expansion
module without power supply.
Barrier Terminal Block
Style Expansion Unit

Program Memory + RTC Card


VB-MP1R VB-32E - C 16-point Input
16-point Output
VB-32XY -C 16-point Input
16-point Output
VB-32XY-C is the expansion
PDA (Palm® OS) based module without power supply.
ATX Connector Style
Programming Tool Data Bank + RTC Expansion Card
Expansion Unit
NeoTouch VB-DB1R

Communication Main Units Expansion Module


Expansion
VB-16XY 8-point Input
8-point Output
VB-16X 16-point Input
VB-16Y 16-point Output
VB-8XY 4-point Input
4-point Output
VB-8X 8-point Input
Barrier Terminal Block VB-8Y 8-point Output
RS-232 Communication Barrier Terminal Block Style
Main Unit Style Expansion Unit
Expansion Card VB-232
VB2-16M - 8-point Input 8-point Output
VB2-32M - 16-point Input 16-point Output VB-16XY -C 8-point Input
VB1-14MT-D 8-point Input 6-point Output 8-point Output
VB1-24MT-D 14-point Input 10-point Output VB-16X-C 16-point Input
VB1-32MT-D 16-point Input 16-point Output VB-8X-C 8-point Input
VB0-14M - 8-point Input 6-point Output VB-8Y -C 8-point output
VB0-20M - 12-point Input 8-point Output
RS-422/RS-485 Communication ATX Connector Style
VB0-28M - 16-point Input 12-point Output
Expansion Card VB-485 Expansion Module
VB0-32M - 16-point Input 16-point Output
VB1-14MT is the 48mm main unit without
Memory Card Slot and I/O Expansion Slot.

Special Module

RS-485 Communication VB-2VC 2-channel Valve Controls


Expansion Module VB-485A VB-4AD 4-channel 12-bit Analog Inputs
ATX Connector Style Main Unit VB-2DA 2-channel 12-bit Analog Outputs
VB2-32M - C 16-point Input 16-point Output VB-4DA 4-channel 8-bit Analog Outputs
VB0-32M - C 16-point Input 16-point Output VB-3A 2-channel 12-bit Analog Inputs 1-channel 12-bit Analog Output
VB-6A 4-channel 12-bit Analog Inputs 2-channel 12-bit Analog Outputs
VB-4T 4-channel J/K TC Temperature Inputs
Indicates the output type VB-8T 8-channel J/K TC Temperature Inputs
R: Relay Output VB-2PT 2-channel PT-100 Temperature Inputs
T: NPN Transistor Output VB-4PT 4-channel PT-100 Temperature Inputs
P: PNP Transistor Output VB-1LC 1-channel Temperature Controls
VB-2LC 2-channel Temperature Controls
Indicates the power type VB-1HC Single channel 45KHz High Speed Counter
Dual Communication
A: AC100-240V – 15%/+ 10% VB-1COM A Serial Link Communication Interface
Expansion Module VB-CADP
D: DC24V – 15%/+ 20% VB-PWR 24W Power Expansion

4
The VB Series Main Units

Memory Card Slot


For an Expansion Cards:
Communication VB-MP1R / VB-RTC
Expansion Slot VR1 Two Analog Rotary
Or VB-DB1R
For an VR2 Potentiometers
Expansion Card: RUN/STOP Switch I/O Expansion Slot
VB-232 / VB-485 Display Mode Switch Available for:
Or
Program Tool 12 Type Expansion Units
Expansion Module:
VB-485A / VB-CADP Communication Port 28 Type Expansion Modules
CP1 RS-232 16 Type Special Modules
Programming Tool
Auxiliary Slot

The Analog Rotary Potentiometers (VR1 and VR2) provide number values (0~255) which can be used for
data inputs (i.e. changing timer settings). If they incorporate with the Multi-Functional Display, the PLC
will have a flexible performance.
The Main Unit has a built-in RUN/STOP switch which allows convenient control to run or stop the PLC.
The Display Mode Switches let the LCD matrix screen become its I/O status display or the Multi-Func-
tional Display.
The Communication Expansion Slot can be used for RS-232 or RS-422/485 communication expansion
cards (VB-232 / VB-485) or modules (VB-485A / VB-CADP).
The Memory Card Slot can be used for program memory (VB-MP1R), Real Time Clock (VB-RTC) or
Data Bank (VB-DB1R) expansion card.
The I/O Expansion Slot can be used for connecting various I/O expansion units/modules or special modules.
The Programming Tool Communication Port is a RS-232 interface (USB A-type outlet), it can be used to
connect with programming tool (computer or PDA), HMI (Human-Machine Interface) or SCADA
(Supervisor Control And Data Acquisition). And also by this port, the remote program modification and
data monitoring through a MODEM are available.
The PLC could communicate via either the Programming Tool Auxiliary Port (JST 4P outlet) or Program-
ming Tool Communication Port CP1 (USB A-type outlet).

Each Main Unit has a built-in a RS-232 interface. The


Program and data can be monitored, uploaded or downloaded
PLC just needs a transmission cable, easy to do pro-
by the programming tool from remote locations via MODEMs.
gramming and monitoring via a computer or PDA.
5
VB Series Main Units

VB1 series High Speed I/O function


VB1 main unit in the VB-PLC family is designed specifically for positioning control.
The build-in 4-point High Speed Pulse Output, 20 KHz from Y0, Y1 and 200 KHz from Y2, Y3, enable the positioning control to be carried
out easily in a faster and more precise manner through using the positioning control instruction. Moreover, for the High Speed Input, not only
did it preserves the VB series interrupt input and high speed counter functions, some improvements have been made to it by adding a 2-point
AB-phase high speed counter hardware which can count the pulse input signal frequency up to 200 KHz. The conjunction of the high speed
pulse output and the high speed counter hardware can complete a close loop positioning control to satisfy the need for accuracy.

X0 A Phase
X1 B Phase
Rotation
Encoder
Y2 200KHz Step Motor/ Motor
Yn DIR Servo Motor
Driver
VB1 Main Unit

DOG
Position Control
Instruction

ZRN Home Position Return PLSV Variable Frequency Pulse DRVI Increment Positioning/
Output DRVA Absolute Positioning

PID control with Auto Tuning(AT) Data Bank Provides Large Capacity
mechanism of Data Storage Function
VB series PLC offer more precise process control via the PID The Main Unit has 7,680 general and 512 latched data registers.
control instruction which can be executed repeatedly. With the To insert a VB-DB1R Data Bank expansion card, it will get extra
premium Auto Tuning(AT) mechanism, the PID parameter set- 128,000 latched data registers, for a storage of huge data is
ting could never be easier. required.

128K words
Thermo- Data Bank
couple Soldering Expansion Card
VB-PLC VB-8T
Main Unit Temperature Pot VB-DB1R
Input Module

Yn
SSR Heater

VB0 VB2 Series Pulse Output Function Interrupt Input and High-Speed
Counter Function
The Main Unit has two points (Y0, Y1) of pulse output (up to 7
The Main Unit has 6 points (X0~X5) of high-speed input which can
kHz). The output pulse can drive the step motor or servo motor
be used as the interrupt and high- speed counter inputs. At most, it
directly.
can be connected to 6 single-phase high-speed counters or 2 AB-
The additional VB-1PG positioning control module is designed for
phase rotation encoders. The additional VB-1HC high-speed
the demand of higher frequency (up to 100 kHz) pulse output. counter module is designed for the demand of higher frequency (up
to 45 kHz) pulse input.

Y0 Motor
A Phase
DIR Driver X0
Step Motor /
Rotation
Servo Motor Encoder
B Phase
X1

Y1 Motor A Phase
Transistor X3
Driver
Output Main Unit DIR
Step Motor / Rotation B Phase
X4
Servo Motor Encoder

6
VB Series Main Units

Multi-Functional Display
This state-of-the-art Multi-Functional Display can be used to show the error messages, procedural flows, texts
and graphics, etc.
When the Multi-Functional Display cooperates with input buttons, it becomes a part of data access interface. A
better utilization will help enhance product added value.

Ladder Master pro-


gramming software
adds simplicity to
multi-functional dis-
play editing through
inputting English
characters, figures
and symbols from a
keyboard. Also, it can
be used to create mes-
sages via the cursor.

Complete System Functions Flexible Modular Structure, With


Built-in a Flash ROM program memory. The capacity size is 16K/8K Multitudinous Models and Modules
steps and no back-up battery is required. The Main Unit providing 14~32 I/O points optional control scales.
The user program, component comments and program comments can The I/O expansion modules provide the control scales from 4X/4Y to
be completely downloaded to the PLC, which isconvenient for system 16X/16Y, fully support expansion features need.
maintenance. Two I/O connection types are available. (Barrier terminal block or ATX
Enable the function of password protection can block program upload. connector)
It prevents unauthorized reading so the intellectual property right can Two types of power input are available. (AC 85~264V or DC 24V)
be guaranteed. Three output types are available. (relay, NPN or PNP transistor)
For the time-based control, it is available to install a Real Time Clock The input point is the Sink/Source selectable connection.
card (VB-RTC).
The Main Unit has a built-in Multi-Functional Display, conveniently Numerous kinds of Special Modules Supply
and timely displays informations.
The integrated Auto Tuning(AT) function solves the complexity of
various Special Applications
PID control. The analog I/O module, temperature input module, pulse output posi-
MBUS instruction in combination with communication table tioning module, high-speed counter module, valve controls module and
editing function makes it easier to connect with MODBUS communication module.
peripherals.
Plenty of instructions, including: floating point, PID and compare Modular Structure, Flexible Combination
instructions, etc. Various of Units and Modules
Full Communication Function Compact and Ingenious Design, Saves
The Main Unit has an RS-232 interface (CP1), it can be connected
Assembling Space.
with a computer, HMI (Human Machine Interface) or SCADA
(Supervisory Control And Data Acquisition). Also available through a Advanced MS Windows® Based Programming
MODEM to remote control, edit program and data observe.
Multiple communication cards and expansion modules provide RS- Software:Ladder Master, Easy Become a
232, RS-485 interfaces. The system can be expanded up to 19 commu- Professional.
nication ports.
Provides various communication functions for complicated requires. Advanced PDA (Palm® OS) Based Screen
e.g. Computer Link, CPU Link, Parallel Link, Easy Link, MODBUS Creation Software: NeoTouch, Inaugurate a
(Master/Slave) Communication, MODEM Communicationand Non-
New Fashion.
Protocol Communication.
Provides the MODBUS (Master/Slave) communication mode, which
promotes its communication capability to other peripherals.
7
VB Series Main Units

Performance Specification

8
VB Series Main Units

Basic Instruction Table

Step Ladder Instruction Table

Applied Instruction Table

9
VB Series Main Units

Regulation Specification

Power Specification (Including All VB Series Main Units and Expansion Units)

Notes for Expansions


All of the VB Series Main Unit will occupy the I/O address X0~X17/Y0~Y17, thus the I/O address of the Expansion Unit/
Module will start from X20/Y20.
All of the VB Series Special Modules will not occupy any I/O address.
The VB-8XY expansion module will occupy 8 input points and 8 output points.
The available I/O points: The number of the Special Modules to be linked:
VB0 Series: Max. 128 points (X0~X77, Y0~Y77); VB0 Series: Up to 4 Special Modules;
VB1 Series: Max. 256 points (X0~X177, Y0~Y177); VB1 Series: Up to 8 Special Modules;
VB2 Series: Max. 512 points (X0~X377, Y0~Y377) VB2 Series: Up to 16 Special Modules.
The statement about I/O expand
The VB series PLC Main Unit and Expansion Unit contain a power supply unit, but the Expansion Module and Special
Module does not have a power unit, those module needs a power source to get power (for example from a Main Unit,
Expansion Unit or VB-PWR Power Expansion Unit).
The statement of available modules amount with a Main Unit, Expansion Unit or VB-PWR Power Expansion Unit:
Two important connecting limits, from a Main Unit to Two important connecting limits, from a VB-PWR
Expansion Modules: Power Expansion Unit to Expansion Modules:
(1) (The amount of Expansion Modules) + (The amount of Special (1) (The amount of Expansion Modules) + (The amount
Modules) X 2 ≤ 4 of Special Modules) X 2 12
(2) All equipments using power form the Main Unit (including itself (2) All equipments using power form the VB-PWR Power
and Expansion Modules), the output points: Expansion Unit, the output points:
The amount of "ON" status relays) X 6 + (The amount of "ON" (The amount of "ON" status relays) X 6 + (The amount
status trans transistors) 192 of "ON" status trans transistors) 288

Two important connecting limits, from an Expansion


Unit to Expansion Modules:
(1) (The amount of Expansion Modules) + (The amount of Special
Modules) X 2 12
(2) All equipments using power form the Expansion Unit (including
itself and Expansion Modules), the output points:
(The amount of "ON" status relays) X 6 + (The amount of "ON"
status trans transistors) 192
10
VB Series Main Units

Input Point Specification

Output Point Specification

11
Formation of Communication System

COM Port 1 (CP1)


The CP1 is a built-in RS-232 communication standard interface. It is available to connect with other equipment via either the USB-
A type or the white JST 4P connector.
The applicable communication type of CP1 is the Computer Link, which is to execute the M, VB and VH Series communication
protocol. Its main purposes are to:
1. Connect to the programming tools (Computer + Ladder Master or PDA + NeoTouch).
2. Connect to the HMI (Human-Machine Interface) or SCADA (Supervisor Control And Data Acquisition).
3. Connect with a MODEM, which is for remote program modification and data monitoring.

COM Port 2 (CP2)


CP2 is a multi-functional expansion communication port and it can be used for various communication applications.
1. Computer Link – Uses the M, VB and VH Series communication protocol and it has the same purpose for use as CP1 in the RS-
232 interface. By the RS-485 interface, a computer and several PLCs can constitute a monitoring local access network.
2. CPU Link – Uses the dedicated communication protocol and it is only available by the RS-485 interface. The CPU Link allows
data transfer between (2~8) PLCs, usually it is used for the distributed control system.
3. Parallel Link – Uses the dedicated communication protocol and it has almost the same purpose as the CPU Link, except its pro-
cedure is simpler and it only allows data to be transferred between 2 PLCs.
4. Easy Link – Uses the M, VB and VH Series communication protocol. Basically this application type is similar to the Computer
Link, except this Easy Link uses a Main Unit of M or VB Series (which is called "Master PLC" ) to replace the computer, HMI or
SCADA in the local network. For the data transfer in the network, programmer need to put the LINK instruction (FNC 89) in the
Master PLC's program to access the data in Slave PLCs.
5. MODBUS – Uses the MODBUS (Master/Slave) communication protocol (the MODBUS is a standard open source communica-
tion protocol). Usually all the SCADA (Supervisor Control And Data Acquisition) and HMI (Human-Machine Interfaces) have
the MODBUS communication protocol. So, if a device without the M, VB and VH Series communication protocol, it can link to
the VB and VH Series PLC's via the MODBUS.
6. MODEM Communication – Actively contacts with a MODEM when the PLC boots up (MODEM's "AA" sign should light
on), then exercises M, VB and VH Series communication protocol. By the linked MODEMs, the PLC allows the user to perform
remote program modification or data monitoring.
7. MODEM Dialing – Uses the function of MODEM Communication described above (if the dialing function of VB Series PLC
and MODEM are activated) and then triggers the PLC's Dial-up Connection to link with the other PLC. The function is very use-
ful, especially for remote abnormality report, security system and data collector.
8. Non Protocol – It does not administer any specific communication protocol. All communication processes are customized and
completed by PLC program. It uses RS instruction (FNC80) to receive and transfer communication operation. This communica-
tion type is usually used for links with other peripherals on the market, such as temperature controller, frequency converter, dis
player, printer, card reader or bar code reader.

COM Port3 (CP3)


The CP3 is a RS-485 communication port which is expanded by the VB-CADP expansion module and the communication type is
assigned as Computer Link (using the M,VB and VH Series communication protocol). It is usually linked with the HMI (Human-
Machine Interface) or the SCADA (Supervisor Control And Data Acquisition) to make the monitoring of local networking.

VB-1COM
The VB Series PLC Serial Link Communication Module provides a RS-232/RS-485 communication port. It does not adminis-
ter any specific communication protocol. All the communication processes are customized and completed by the PLC program.
This module is usually used to communicate with other peripherals, such as commercially available temperature controller,
frequency converter or bar code reader. A Main Unit can be connected with up to 16 VB-1COM modules.
12
Formation of Communication System

Communication
Expansion Card
The VB-232 and VB-485 are the Second COM Port
(CP2) expansion cards of the VB Series PLC.
The CP2 of the VB Series PLC is a multi-functional
communication port that can be used for multifari-
ous communication types, e.g. Computer Link,
VB-232 VB-485
CPU Link, Parallel Link, Easy Link, MODBUS
The RS-232 Communication The RS-485 Communication
Communication, MODEM Communication and
Expansion Card Expansion Card
Non-Protocol Communication.

13
Formation of Communication System

VB-CADP Dual-Port Communication


Expansion Module
It is a CP2 and CP3 expansion module.
The CP2 provides an isolated RS-232 or RS-485 communication interface.
The communication distance of its RS-485 interface is up to 1000 M (3280').
The CP3 provides isolated RS-485 communication interface with the com-
munication distance of this RS-485 interface is up to 1000 M (3280').
The CP2 of the VB Series PLC is a multi-functional communication port
which can be assigned for various communication applications, e.g.
Computer Link, CPU Link, Parallel Link, Easy Link, MODBUS Communica-
tion, MODEM Communication and Non-Protocol ommunication.

After linking VB-CADP Module, the Main Unit's CP1 will be disabled, and its function will be replaced by
VB-CADP’s CP1.
VB-CADP Module provides RX, TX indicator lamps of PWR and CP1.

14
Formation of Communication System

VB-485A RS-485 Communication


Expansion Module
The Second COM Port (CP2) expansion module for a Main Unit.
It is an isolated RS-485 communication interface, the distance is up to
1000 M (3280').
The CP2 of the VB Series PLC is a multi-functional communication port
that can be assigned for various communication applications, e.g.
Computer Link, CPU Link, Parallel Link, Easy Link, MODBUS
Communication, MODEM Communication and Non-Protocol
Communication.

VB-1COM Serial Link


Communication Module
The VB-1COM is a VB Series special module.
The VB-1COM can be used for either RS-232 or RS-485 interface.
Both the RS-232 and RS-485 interfaces are isolated. The communication
distance of its RS-485 interface is up to 1000 M (3280').
The module has the HEX and ASCII codes auto conversion function for
the data receive/transfer.
A Main Unit can be connected with up to 16 VB-1COM modules.

15
Communication Operation Modes

The VB Series PLC have complete communication functions. It provides several communication operation modes, which
can be used for various applications. (such as local network monitoring, dispersive control, links to peripherals, MODEM
communication, etc.) The following are the communication operation modes of the VB Series.

Computer Link
A computer, HMI (Human-Machine Interface) or SCADA (Supervisor Control And Data Acquisition) can connect to PLCs via the Computer
Link. It uses the M, VB and VH Series communication protocol.

OR +

Easy Link
PLC uses the CP2 via the M,
VB and VH Series communi-
cation protocol, by the pro-
gram of Master (a M or VB
series) PLC to control the data
transfer between PLCs.

16
Communication Operation Modes

Parallel Link
By this configuration setting, two PLCs use the dedicated communication protocol to transfer specific data automatically.

CPU Link
PLC will enable dedicated
communication protocol, and
PLCs in the network will
transfer data automatically
depending on configuration
settings.

CPU Link Communication Time:

17
Communication Operation Modes

MODBUS Communication
Communication between PLC and Computer, HMI (Human-machine Interface), SCADA (Supervisor Control And Data Acquisition) and
other devices, via the MODBUS communication protocol.

Component Convert Table Between


VB-PLC and MODBUS

PLC can communicate with MODBUS enabled devices using MODBUS communication protocol.

MODEM Communication
This communication mode is implemented by the M and VB, VH Series communication protocol. When a computer using this mode through
the telephone system, it allows to telecommute monitor a PLC, and it also can do the system maintenance or data collection.

MODEM Dialing
M and VB, VH Series PLC have specific Registers to memorize the telephone numbers, which can be used for the MODEM Dialing function.
The on-site PLCs through this MODEM Dialing function, will transfer data automatically to the monitoring center;s M and VB, VH series
PLC for data collection. Also, they can dial-up a pager or cellular phone for caller ID display.

18
Communication Operation Modes

Non-Protocol Communication
M VH and VB series PLC can use this Non-Protocol Communication function, it does not administer any specific communication protocol. All
communication processes are customized and completed by PLC program, which is for connection with various equipment does not have the stan-
dard protocol.

CP 2 Non-Protocol Communication Specification

VB-1COM Communication Specification

19
Special Module

VB-2VC 2-Channel Valve


Controls Module
High current driving capability (up 1.05A ±5% per channel).
Equipped with high resolution 12-bit DAC for high precision control.
Fully digital control including MIN and MAX current, rising or falling
Slope and Mode of slope.
Provide another S-type slope mode for accelerating and decelerating
automatically.
Very wide range of adjustment of slope for each channel.
High efficiency switching mode operation for reducing power dissipation.
Operation by single DC power (Vs) or just only voltage on 24 (+,-) sup-
plied for downgrade power supply cost.
Equipped with Poly Switch (self-recovery Fuse) for downgrade the main-
tenance cost.

VB-2DA 2-Channel, 12-Bit


Analog Output Module
12-bit resolution provides high precision resolution.
The voltage or current output can be specified for each channel inde-
pendently.
The gain and offset of each output channel can be adjusted indepen-
dently.
Photocoupler isolation between output analog signals and digital PLC
circuits. Inner DC to DC isolated converter supplies the clean power.

VB-4DA 4-Channel, 8-Bit


Analog Output Module
Providing 5 output modes: 0V ~ +10V; 0V ~ +5V; +1V ~ +5V; 0 mA ~
+20 mA and +4 mA ~ +20 mA
The voltage or current output can be specified for each channel and
the conversion characteristic of each output channel can be set inde
pendently.
Photocoupler isolation between output analog signals and digital PLC
circuits. Inner DC to DC isolated converter supplies the clean power.

20
Special Module

VB-4AD 4-Channel, 12-Bit


Analog Input Module
12-bit resolution provides high precision resolution.
The voltage or current input can be specified for each channel inde-
pendently.
The gain and offset of each input channel can adjust independently.
Equipped with a 10V accurately standard voltage output, offers refer-
ence power source for the linear potentiometer
Photocoupler isolation between input analog signals and digital PLC
circuits. Inner DC to DC isolated conver ter supplies the clean
power.

VB-6A 4-Channel, 12-Bit Analog Input /


2-Channel, 12-Bit Analog Output Module
VB-3A 2-Channel, 12-Bit Analog Input /
1-Channel, 12-Bit Analog Output Module
12-bit resolution provides high precision resolution.
The voltage or current input can be specified for each channel independently.
The voltage or current output can be specified for each channel independently.
The gain and offset of each input/output channel can be adjusted independently.
A 10V accurately standard voltage output, offers reference power source for the
linear potentiometer.
Photocoupler isolation between analog I/O signals and digital PLC circuits.
Inner DC to DC isolated converter supplies the clean power.
Analog Input Feature Specification

Analog Output Feature Specification

Common Specification

21
Special Module

VB-8T 8-Channel J/K TC Temperature


Input Module
VB-4T 4-Channel J/K TC Temperature
Input Module
Each input channel can be set to J or K type thermocouple sensor
input. Also it is possible to set the temperature range and resolution for
each input channel independently.
The 0.1 / 0.18 high resolution temperature detection.
The instrument-level "Dual-Slope ADC" can give accurate and stable
measurement values. Also it filters out white noise induced by 50/60Hz
power line.
The Centigrade ( ) or Fahrenheit ( ) measurement values are available.
Providing the temperature sensors' open circuit detective function.

VB-4PT 4-Channel PT-100 Temperature


Input Module
VB-2PT 2-Channel PT-100 Temperature
Input Module
Each input channel can be set its temperature range and resolution
independently.
The 0.1 high resolution temperature detection.
The instrument-class "Dual-Slope ADC" can give accurate and stable
measurement values. Also it filters out white noise induced by 50/60 Hz
power line.
The Centigrade ( ) or Fahrenheit ( ) measurement values are avail
able.
Providing the temperature sensors' open circuit detective function.

22
Special Module

VB-2LC 2-Channel Temperature


Control Module
VB-1LC 1-Channel Temperature
Control Module
Equipped with temperature input(s), PID calculation output control(s)
and plenty warning modes.
Providing with the Auto-Tuning function, easily to get the parameters of PID.
2 (VB-2LC) / 1 (VB-1LC) temperature input channel(s) (PT-100 RTD or
J / K type thermocouple sensor) and 2 /1 transistor (open collector)
output channel(s).
Providing the temperature sensors' open circuit detective function.
Providing the Current Transformer detection that can check the status
of heater.

Input Feature Specification

Output Feature Specification

Performance Specifications, Power Supply and Common Items

23
VB-1PG Single Axis Pulse Output
Positioning Control Module
Equipped with seven operation modes, easy to perform positioning
control.
Up to 100 kHz output pulse chains.
Providing two pulse output formats: Forward (FP) / Reverse (RP)
pulse or pulse chains (PLS) + direction control (DIR) output.
Providing with DOG, PGO and STOP input terminals.
Multiple axes can be controlled by connecting multiple VB-1PG
modules.

VB-1HC High Speed Counter Module


One-phase, two-phase or A/B-phase pulse input is available.
A/B-phase pulse counting can be set to 1, 2 or 4 multiplication
mode.
Equipped with the hardware comparator for its two output points.
Providing software/hardware "Disable Counting" and "Preset"
functions.
Each input is available to use 5V, 12V or 24V signal (depending on the
connection terminal).

150KHz 100KHz 50KHz 50KHz 40KHz

24
Accessories

VB-PWR
Power Expansion Module

VB-30PS Power Supply Module

DAP-100 Configuration Panel

Memory Card Slot Expansion Cards


With in of the Real Time Clock Expansion Card, the PLC will enable to do
the automatic control according to date and time.
To indicates the year, month, day, hour, minute, second and week.
The battery life is around 5 years at 25 77 .
VB-RTC Real Time Clock Expansion Card When the battery power is too low, the special relay M9005 will turn "ON".

The 16K Steps Program Memory Card. Use a Flash ROM, can rewrite
over 10,000 times. (Only 8K steps capacity, if it is installed in a VB0
series Main Unit.)
Providing program upload/download function, easy for program copy and
machine maintenance.
Including the RTC function, the battery life is around 5 years at 25 77 .
VB-MP1R Program Memory Card
When the battery power is too low, the special relay M9005 will turn "ON".

The 128K words Data Storage Card. The data storage is using SRAM,
and the Lithium batteries are used for latched data.
Providing storage room for extensive data which needs the latched func-
tion. The VB-DB1R is usually used for storage formula data or long-time
data collection.
Using the DBWR and DBRD instructions to access data in the VB-DB1R.
VB-DB1R Data Bank The development software Ladder Master is available to modify, archive
Expansion Card and upload/download the data in the VB-DB1R.
Including the RTC function, the battery life is around 5 years at 25 77 .
When the battery power is too low, the special relay M9005 will turn "ON".
25
Accessories

Connecting Cables

26
Dimension and Terminal Layouts

94mm Model

27
Dimension and Terminal Layouts

48mm Model

28
Programming Tool

MS Windows®-based Programming Tool : Ladder Master


The Ladder Master is a Ladder-Diagram programming software, which is based on the Microsoft ®
Windows® operating system and specially developed for M, VB and VH Series PLC. With the use of a
mouse and keyboard, it features good friendliness, easy to learn, understand and operate.
The Ladder Master provides powerful and complete functions in programming, operation monitoring
and system maintenance. It will effectively help you to complete the job.

The operating habit is correspond with the Windows® environment, which has the advantage of easy
to learn, application and good friendliness.
Providing various language versions, such as Traditional Chinese, Simple Chinese and English ver-
sions, that are convenient for different language users.
Providing direct connection and MODEM connection functions, which allows remote program modi-
fication and data monitoring.
Its quick input mode enhances the programming efficiency by processing diagram input and compo-
nent assignation separately.
Featuring the Insert, Delete, Cut, Copy, Paste, Undo and Export/Import functions.
Providing 16 letters of component annotations plus sectional program annotations, which can be
fully express the program denotation and improve program readability.
During the programming processes, the Ladder Master provides the guidelines of reference, which
will give the real-time error retrieved and the instant prompts.
29
Programming Tool

Simultaneous monitoring of the ladder


diagram and component status, allows
efficiently program debugging.
Selectable group monitoring function for
component facilitate the use of the moni-
toring layout.
Providing component enforce functions:
contacts force "ON"/"OFF" and Registers'
present value input.
For easier test run, debug and system
maintenance, the monitoring function of
Ladder Master could select monitored
components. It also allows to keep the
assigned monitoring page.
The system configuration is set by dia-
logue box, enables easy system parameter
settings.
The print function is available for the pro-
gram itself and parameter list, easy to
record and create of engineering docu-
ment/data.
For the latched area, File Register and
Data Bank, it provided the editing and
archiving functions, which offering the
easy system maintenance and duplication
of machine data.

Palm OSTM-based PDA Programming Tool : NeoTouch


The NeoTouch is an application program interface, which is specially developed for M, VB and VH
Series PLC. The NeoTouch is designed to install at a Palm OSTM PDA, it offers many functions better
than those of the Handy Programming Panel. This advanced design idea creates a new generation of
PLC program writers.

A PDA has the features compactness and


mobility with the self-contained power, it can
operate independently.
The touch screen cooperated with the dia-
logue boxes which allows to learn and opera-
tion easily.
The larger screen could display 11 lines of
instructions in one page, that is very helpful
for the programming and operation monitor-
ing.
Featuring the modern programming edit
functions, such as Cut, Copy, Paste and
Undo. PDA-based
The powerful component replacement func- NeoTouch
tion, that enables to exchange multiple com-
ponents at once and it is good for various
component types.
Allowing to monitor the program and select-
ed components simultaneously. The moni-
tored components could be changed anytime
by the demand of application.
Providing component enforce functions: con-
tacts force "ON"/"OFF" and Registers' pre-
sent value input.

30
VB Series Product List

Max. 150KHz Input; 2 hardware comparator outputs

31
Ta i p e i H e a d O f f i c e / TEL:886-2-2620-4393 FAX:886-2-2620-4976

http://www.vigorplc.com

Specifications are subject to change without notice.


May 2015

You might also like