TECHNICAL GUIDE
Description
YORK® ZE/XN Series units are convertible single package
rooftops with a common roof curb for the 3, 4, 5, and 6 Ton
sizes. Although the units are primarily designed for curb
mounting on a roof, they can also be slab-mounted at ground
level or set on steel beams above a finished roof.
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Typical Field Power and Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Component Location
Gas/Electric
Compressor
HACR
Breaker
Economizer
Hood
Highly Efficient
Enhanced Copper
Tube/Enhanced
Aluminum Fin
Or
Knockout
Micro-Channel
For Side
Aluminum Tube/
Power Entry
Aluminum Fin
Condenser
Slide-In
Economizer
Smoke
Detector
Compressor
HACR
Breaker
Economizer
Hood
Highly Efficient
Enhanced Copper
Tube/Enhanced
Aluminum Fin
Or
Knockout Micro-Channel
For Side Aluminum
Power Entry Tube/Aluminum
Fin Condenser
Slide-In
Economizer
Smoke
Detector
Nomenclature
A = Std Cabinet
Product Identifier
B = HDF(HingedFLTR/Tooless DR)
E = Standard Efficiency E = SSD (SST Drain Pan)
N = Standard Efficiency F = SSD, HFD
Additional Options
Nominal Cooling Capacity
1 = Std Throwaway Filter
036 = 3 Ton 2 = 2" Pleated Filters (Merv 8)
048 = 4 Ton 4 = Coil Guard (CG), STD Filter
060 = 5 Ton 5 = 2" Pleated Filter,CG
072 = 6 Ton
Refrigeration
Heat Type
A = Standard Refrigeration
C = Cooling Only B = ECC (E-Coat Cond Coil)
E = Electric Heat C = EEC (E-Coat Evap Coil)
Single Stage Natural Gas Heat Options F = ECC,EEC
1 = 208/230-1-602
2 = 208/230-3-60 Outdoor Air Option
4 = 460-3-60
5 = 575-3-60 A = No Economizer
C = Economizer w/o Barometric RLF
2. 3 - 5 ton only F = Econ BAS Rdy w/o Barometric RLF
H = Motorized Damper
Standard Features
• Efficiency - The 3 thru 5 ton units reach 14.0 SEER. The
6 ton unit reaches 14.2 IEER with the standard, factory-
installed IntelliSpeed variable frequency drive. Gas/
electric units have electronic spark ignition and power
vented combustion with steady state efficiencies of 80%.
The heat pumps reach 14 SEER and 8.0 H.S.P. F. These
efficiencies meet all legislated minimum levels and
provide low operating costs.
• DOE (Department of Energy) Compliant - All ZE models
meet minimum DOE efficiencies for cooling and fan
efficiencies. Single phase gas heating products are fan
energy rated (FER) to meet DOE requirements.
NOTE: All single phase 3 to 5 ton gas heating units are
equipped with an ECM motor on direct drive units and a
VFD on belt drive units.
wired with AMCA 511 Licensed Class 1A low leak to the control board if smoke is detected within the air
dampers designed to exceed ASHRAE 90.1 and the compartment.
International Energy Conservation Code (IECC)
certification requirements by achieving leakage rates of 3
cfm/ sq. ft. at 1" of static pressure. Each economizer goes
through a rigorous 60,000 cycle test. Dry bulb, single
enthalpy, and dual enthalpy (with field installed kit) can be Factory installed smoke detectors in the return air, may
selected. All economizer options are fully integrated into be subjected to freezing temperatures during “off” times
the Smart Equipment™ controls. The economizer has due to out side air infiltration. These smoke detectors
spring return, fully modulating damper actuators and is have an operational limit of 32°F to 131°F. Smoke
capable of introducing up to 100% outdoor air. As the detectors installed in areas that could be out side those
outdoor air intake dampers open, the return air dampers limitations will have to be moved to prevent having false
close. The changeover from mechanical refrigeration to alarms.
economizer operation is regulated by the outdoor air dry
bulb temperature or the outdoor air enthalpy input. The • Coil Guard - Customers can purchase a coil guard kit to
dual enthalpy kit provides a second input used to monitor protect the condenser coil from damage. This is not a hail
the return air (field installed). The installer needs only to guard kit.
assemble the outdoor air hood, attach the enthalpy control
the hood and mount the hood to the unit (hood and control • Stainless Steel Heat Exchanger - For applications in
are provided). corrosive environments, this option provides a full
stainless steel heat exchanger assembly.
• Dry Bulb Economizer - Economizer operation is
enabled by the outdoor air temperature being less than • Stainless Steel Drain Pan - An optional rustproof
the setpoint of the economizer module. stainless steel drain pan is available to provide years of
trouble-free operation in corrosive environments.
• Enthalpy Economizer - The added outdoor air enthalpy
• Bottom Drain Connection - An optional bottom drain
sensor enables economizer operation if the outdoor
connection is available for inside the curb connections for
enthalpy is less than the setpoint of the economizer
applications in cold environments to reduce freezing drain
logic module.
lines.
• Motorized Outdoor Air Intake Damper -Includes a slide- • Phase Monitors - Designed to prevent unit damage. The
in / plug-in damper assembly with a 2-position, spring phase monitor will shut the unit down in an out-of phase
return motor actuator which opens to a pre-set position condition.
whenever the supply air blower is operating and will drive
• Dirty Filter Switch - This kit includes a differential
fully closed when the blower unit shuts down.
pressure switch that energizes the fault light on the unit
The rain hood is painted to match the basic unit and must thermostat, indicating that there is an abnormally high
be field assembled before installing. pressure drop across the filters. Factory installed option or
• E-Coat Condenser Coils - The condenser coils are field installed accessory.
coated with an epoxy polymer coating to protect against • Hinged & Toolless Filter, Motor and Electrical Access
corrosion. Panels - This option allows for easy access and
• E-Coat Evaporator Coils - The evaporator coils are maintenance.
coated with an epoxy polymer coating to protect against NOTE: Knobs are shipped inside the unit to prevent shipping
corrosion. damage. These must be field installed for tool-less
• Electric Heaters - Wired for single point power supply. operation.
These nickel chromium heater elements are provided with
limit and automatic reset capability to prevent operation at • High Static Drive - May include a belt, blower pulley,
excessive temperatures. motor pulley or a motor change to enhance blower
performance.
• Filter Options - Standard units are shipped with 1" throw-
away filters installed. 2" Pleated Filters, MERV 8 are
Control Options
offered as a factory installed option.
• Convenience Outlet - This 110 volt outlet can be • Smart Equipment™ with Communication Option
“powered” by the unit with a stepdown transformer or the Control - The York® Smart Equipment™ with
unit may be ordered with a “non-powered” convenience Communication Option Control is factory installed. It
outlet that can be wired in the field. includes all the features of the Smart Equipment™ control
• Disconnect Switch - For gas heat units and cooling units with an additional gateway to BACnet MS/TP
with electric heat, a HACR breaker sized to the unit is (programmable to Modbus or N2 protocols).
provided. For cooling only units, a switch sized to the • Novar® BAS Control - The Novar® building automation
largest electric heat available for the particular unit is system controller is factory installed. Incudes supply air
provided. Factory installed option only. sensor, return air sensor, dirty filter indicator switch, and
• Smoke Detectors - (supply air & return air) The smoke air proving switch.
detectors stop operation of the unit by interrupting power
• CPC BAS Control - The Computer Process Controls return motor actuator which opens to some pre-set
Model 810-3060 ARTC Advanced Rooftop building position whenever the supply air blower is operating and
automation system controller is factory installed. Includes will drive fully closed when the blower unit shuts down.
supply air sensor, return air sensor, dirty filter indicator The rain hood is painted to match the basic unit and must
switch and air proving switch. be field assembled before installing.
• Honeywell BAS Control - The Honeywell W7750C • Electric Heaters - wired for single point power supply.
building automation system controller is factory installed.
These nickel chromium heater elements are provided with
Includes air supply sensor, return air sensor, dirty filter
limit and automatic reset capability to prevent operation at
indicator switch, and air proving switch.
excessive temperatures.
• Verasys - Verasys provides a simple user experience
• Roof Curbs - Eight and fourteen-inch high roof curbs
with configurable self-recognizing controllers without the
provide a water-tight seal between the unit and the finished
need for any additional tools. Verasys creates enhanced
roof. These full perimeter curbs meet the requirements of
integration of HVACR equipment, zoning, and controls.
the National Roofing Contractors Association (NRCA) and
Contractors are able to offer a complete bundled solution
are shipped knocked-down for field assembly.
of equipment and controls to serve the light commercial
market. Roof curbs are designed to fit inside the base rails of the
unit and include both a wood nailing strip and duct hanger
Field Installed Accessories supports.
• High Altitude Natural Gas - Burner orifices and pilot
NOTE: Simplicity Lite models are only available with a field orifices are provided for proper furnace operation at
installed RRS economizer, which is equipped standard altitudes up to 6,000 feet.
with single enthalpy control (dual enthalpy available as
field installed kit). Smart Equipment™ models are • Propane - Burner orifices, pilot orifices and gas valve
available with factory or field installed economizers parts are provided to convert a natural gas furnace to
including options for a Smart Equipment™ controlled propane.
economizer or an externally controlled BAS economizer • High Altitude Propane - Burner orifices and pilot orifices
where both feature standard dry bulb control (single are provided for proper furnace operation at altitudes up
and dual enthalpy available as field installed kits). to 6,000 feet. This accessory supplements the basic
propane conversion kit.
• Economizers - All units offer a variety of optional field
• Low Nox Kit - Required to reduce the emission of
installed economizers that are shipped, installed and
nitrogen oxides below 40 nano grams per joule.
wired with AMCA 511 Licensed Class 1A low leak
dampers designed to exceed ASHRAE 90.1 and the • Power Exhaust - Our single input economizer options are
International Energy Conservation Code (IECC) available with power exhaust. Whenever the outdoor air
certification requirements by achieving leakage rates of 3 intake dampers are opened for free cooling, the exhaust
cfm/ sq. ft. at 1" of static pressure. Each economizer goes fan will be energized to prevent the conditioned space from
through a rigorous 60,000 cycle test. Dry bulb, single being over-pressurized during economizer operation.
enthalpy, and dual enthalpy (with field installed kit) can be The power exhaust option can only be used on bottom
selected. All economizer options are fully integrated into duct configurations.
the Smart Equipment™ controls. The economizer has • Barometric Relief Damper - This damper accessory can
spring return, fully modulating damper actuators and is be used to relieve internal building air pressure on units
capable of introducing up to 100% outdoor air. As the with an economizer without power exhaust. This
outdoor air intake dampers open, the return air dampers accessory includes a rain hood, a bird screen and a fully
close. The changeover from mechanical refrigeration to assembled damper. With bottom duct connections, the
economizer operation is regulated by the outdoor air dry damper should be mounted over the opening in the return
bulb temperature or the outdoor air enthalpy input. The air panel. With horizontal ductwork, the accessory should
dual enthalpy kit provides a second input used to monitor be mounted on the return air duct.
the return air (field installed). The installer needs only to
• Enthalpy Accessory Control Kit - This kit contains the
assemble the outdoor air hood, attach the enthalpy control
required components to convert a single enthalpy
the hood and mount the hood to the unit (Hood and
economizer to dual enthalpy.
control are provided).
• Burglar Bars - Mount in the supply and return openings
• Dry Bulb Economizer - Economizer operation is
to prevent entry into the duct work.
enabled by the outdoor air temperature being less than
the setpoint of the economizer module. • Flue Exhaust Extension Kit - In locations with wind or
weather conditions which may interfere with proper
• Enthalpy Economizer - The added outdoor air enthalpy exhausting of furnace combustion products, this kit can be
sensor enables economizer operation if the outdoor installed to prevent the flue exhaust from entering nearby
enthalpy is less than the setpoint of the economizer fresh air intakes.
logic module.
• CO2 Sensor - Senses CO2 levels and automatically
• Motorized Outdoor Air Intake Damper -Includes a slide- overrides the economizer when levels rise above the
in / plug-in damper assembly with a 2-position, spring present limits.
• Coil Guard - Customers can purchase a coil guard kit to accessories. The units shall be factory wired, piped, charged
protect the condenser coil from damage. This is not a hail with R-410A refrigerant and factory tested prior to shipment. All
guard kit. unit wiring shall be both numbered and color coded. All units
• Hail Guard - Hail Guard kit is available to prevent unit the cooling performance shall be rated in accordance with DOE
from hail damage. This is a sloped hood that fits above and AHRI test procedures. Units shall be CSA listed, classified
the coil. to ANSI Z21.47, UL 1995/CSA No. 236 standards.
• Gas Piping Kit - This kit supplies all necessary fittings Unit Cabinet
and shut off valve.
Unit cabinet shall be constructed of galvanized steel, with
Guide Specifications exterior surfaces coated with a non-chalking, powdered paint
finish, certified at 750-hour salt spray test per ASTMB117
General standards. Indoor blower section shall be insulated with a
minimum 1/2” thick insulation, coated on the airside. Aluminum
York's ZE/XN units are convertible single package units. foil faced insulation shall be used in the furnace compartment
Although the units are primarily designed for curb mounting on and be fastened with ridged fasteners to prevent insulation from
a roof, they can also be slab-mounted at ground level or set on entering the air stream. Cabinet panels shall be “large” size,
steel beams above a finished roof. Cooling only, cooling with easily removable for servicing and maintenance. Full perimeter
gas heat, cooling with electric heat and heat pump with electric base rails shall be provided to assure reliable transit of
heat models are available with a wide variety of factory- equipment, overhead rigging and proper sealing on roof curb
mounted options and field-installed accessories to make them applications. Disposable 1" filters shall be furnished and be
suitable for almost every application. All units are self-contained accessible through a removable access door, sealed airtight.
and assembled on full perimeter base rails with holes in the four Units filter track shall be designed to accommodate either 1" or
corners for overhead rigging. Every unit is completely piped, 2" filters. Fan performance measuring ports shall be provided
wired, charged and tested at the factory to simplify the field on the outside of the cabinet to allow accurate air
installation and to provide years of dependable operation. All measurements of evaporator fan performance without removing
models (including those with an economizer) are suitable for panels or creating air by-pass of the coils. Condensate pan
either bottom or horizontal duct connections. Models with power shall be internally sloped and conform to ASHRAE 62-89 self-
exhaust are suitable for bottom duct connections only. For draining standards. Condensate connection shall be a minimum
bottom duct, remove the sheet metal panels from the supply of 3/4” I.D. female and be a ridged mount connection.
and return air openings through the base of the unit. For
horizontal duct, remove the supply and return air panels on the Indoor (Evaporator) Fan Assembly
rear of the unit.
The indoor fan shall be a factory installed direct-drive or belt-
All non-Scroll compressors include crankcase heaters and all drive assembly that includes an adjustable pitch motor pulley.
compressors have internal pressure relief. Every refrigerant Job site selected brake horsepower (B.H.P.) shall not exceed
circuit includes a liquid line filter-drier, a discharge line high the motors nameplate horsepower rating, plus the service
pressure switch and a suction line with a freezestat and low factor. Units shall be designed not to operate above service
pressure/loss of charge switch.The unit control circuit includes factor. Fan wheel shall be double-inlet type with forward-curved
a 75 VA transformer, a 24-volt circuit breaker and a relay board blades, dynamically balanced to operate smoothly throughout
with a compressor lockout circuit, a terminal strip for thermostat the entire range of operation. Airflow design shall be constant
wiring, plus an additional set of pin connectors to simplify the air volume. Bearings shall be sealed and permanently
interface of additional field controls. All models are CSA listed. lubricated for longer life and no maintenance.
All models include a 1-year limited warranty on the complete
unit. Compressors and factory installed electric heater elements Outdoor (Condenser) Fan Assembly
carry a 5-year warranty. Aluminized steel and Stainless steel
tubular heat exchangers carry a 10-year warranty. The outdoor fan shall be of the direct-drive propeller type (3-5
ton units), discharge air vertically, have aluminum blades
Description riveted to a corrosion resistant steel spider bracket and shall be
dynamically balanced for smooth operation. The outdoor fan
Units shall be factory-assembled, single packaged, Electric motor shall be totally enclosed with permanently lubricated
Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat bearings, internally protected against overload conditions and
Pump/Optional Electric Heat and are designed for outdoor staged independently.
mounted installation.
Refrigerant Components
The 3 ton, 4 ton, and 5 ton units shall have minimum SEER
rating of 14.0 with heat pumps having a 8.0 H.S.P.F. The 6 ton Compressor:
units shall have a minimum IEER rating of 14.2. They shall have a. Shall be internally protected with internal high-pressure
built-in field convertible duct connections for down discharge relief and over temperature protection.
supply/return or horizontal discharge supply/return, and be
available with factory installed options or field installed
b. Shall have internal spring isolation and sound muffling to j. Control board shall monitor each refrigerant safety switch
minimize vibration and noise, and be externally isolated independently.
on a dedicated, independent mounting.
k. Control board shall retain last 5 fault codes in non volatile
Coils: memory which will not be lost in the event of a power loss.
a. Evaporator coils shall have aluminum plate fins Gas Heating Section (Single Or 2 Stage)
mechanically bonded to seamless internally enhanced
copper tubes with all joints brazed. Special Phenolic Shall be designed with induced draft combustion with post
coating shall be available as a factory option. purge logic, energy saving direct spark ignition, and redundant
b. Evaporator coils shall be of the direct expansion, draw- main gas valve. Venter wheel shall be constructed of stainless
thru design. steel for corrosion resistance. The heat exchanger shall be of
the tubular type, constructed of T1-40 aluminized steel for
c. Condenser coils shall have aluminum plate fins corrosion resistance and allowing minimum mixed air entering
mechanically bonded to seamless internally enhanced temperature of 25°F. Burners shall be of the inshot type,
copper tubes with all joints brazed or Micro-Channel constructed of aluminum coated steel and contain air mixture
aluminum tube, aluminum fins. adjustments. All gas piping shall enter the unit cabinet at a
d. Condenser coils shall be of the direct expansion, draw- single location through either the side or curb without any field
thru design. modifications. Integrated control boards shall provide timed
control of evaporator fan functioning and burner ignition.
Refrigerant Circuit and Refrigerant Safety Components shall Heating section shall be provided with the following minimum
include: protection:
a. Independent, fixed-orifice, or thermally operated a. Primary and auxiliary high-temperature limit switches.
expansion devices.
b. Induced draft motor speed sensor.
b. Filter drier/strainer to eliminate any moisture or foreign
c. Flame roll out switch.
matter.
d. Flame proving controls.
c. Accessible service gage connections on both suction
and liquid lines to charge, evacuate, and measure e. If any of the above safety devices trip, a LED (light-
refrigerant pressure during any necessary servicing or emitting diode) indicator shall flash a diagnostic code that
troubleshooting, without losing charge. indicates which safety switch has tripped.
d. The refrigeration system shall provide at least 15°F of NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40%
sub-cooling at design conditions. Capacity 2nd Stage.
i. Standard controls shall include anti-short cycle and low Electrical Requirements
voltage protection, and permit cooling operation down to
0°F. All unit power wiring shall enter unit cabinet at a single factory
provided location and be capable of side or bottom entry, to
minimize roof penetrations and avoid unit field modifications.
Separate side and bottom openings shall be provided for the • High Altitude - Propane Gas - Contains orifices required
control wiring. for applications between 2000 and 6000 feet altitude.
Must be used with propane conversion kit.
Standard Limited Warranties • Low Nox - Required to reduce the emission of nitrogen
• Compressor 5 Years oxides below 40 nanograms per joule.
• Heat Exchanger 10 Years • Gas Piping - Contains 1/2” pipe nipples, fittings and gas
cock (including panel access gaskets) required for bottom
• Factory Installed Electric Heat Element 5 Years gas supply connection with external shut off.
• Other Parts 1 Year
• Power Exhaust Option - To work in conjunction with
Optional Outdoor Air economizers.
• Electric Heaters
Shall be made available by either/or:
• Economizer/motorized Damper Rain Hood - Contains
• Dry Bulb Automatic Economizer - Outdoor and return air all hood panels and the hardware for assembling.
dampers that are interlocked and positioned by a fully- • Manual Outdoor Air Damper
modulating, spring-return damper actuator. The maximum
• Coil Guard Kit - Guard for cooling coil.
leakage rate for the outdoor air intake dampers shall be
designed to meet ASHRAE 90.1, AMCA 511 Class 1A • Hail Guard
damper, and the International Energy Conservation Code • Flue Exhaust Extension
(IECC) certification requirements by achieving leakage
rates of 3 cfm/sq. ft. at 1" of static pressure. Changeover OTHER FACTORY INSTALLED OPTIONS
from compressor to economizer operation shall be provided
• Power Exhaust Option - To work in conjunction with
by an integral electronic enthalpy control that feeds input
economizers.
into the basic module. The outdoor intake opening shall be
covered with a rain hood that matches the exterior of the • Stainless Steel Heat Exchanger
unit. Water eliminator/filters shall be provided. • Stainless Steel Drain Pan
Simultaneous economizer/compressor operation is also • Bottom Drain Connection
possible. Dampers shall fully close on power loss. Available
• E-Coat Epoxy Polymer Coated Condenser and
with barometric relief and power exhaust.
Evaporator Coil
• Motorized Outdoor Air Dampers - Outdoor air dampers
• Electronic Single Enthalpy Economizer
are positioned by a 2-position, spring-return damper
actuator. A unit-mounted potentiometer shall be provided • Dirty Filter Switch
to adjust the outdoor damper assembly to take in the • Phase Monitor
design CFM of outdoor air to meet the ventilation • Coil Guard
requirements of the conditioned space during normal
operation. Whenever the indoor fan motor is energized, • Powered GFI Convenience Outlet
the dampers open up to one of two pre-selected positions • Non-powered GFI Convenience Outlet
- regardless of the outdoor air enthalpy. Dampers return to • BAS Controls - Smart Equipment™ with BAS
the fully closed position when the indoor fan motor is de- Communication (BACnet MS/TP, Modbus, and
energized. Dampers shall fully close on power loss. Johnson Controls N2) Option, CPC, HONEYWELL,
NOVAR, YORK
Other Pre-engineered Accessories Available
• Bas Ready Economizer (2-10 V.D.C. Actuator without
• Roof Curb - 14"and 8” high, full perimeter curb with wood a Controller)
nailer (shipped knocked-down). • Hinged Filter Door Access and Toolless Access
• Barometric Relief Damper - Contains a rain hood, air Panels
inlet screen, exhaust damper and mounting hardware. • 2" Pleated Filters, MERV 8
Used to relieve internal air pressure through the unit. • Disconnect Switch
• Propane Conversion Kit - Contains new orifices and gas • Supply Air Smoke Detector
valve parts to convert from natural to L.P. gas. One per
unit required. • Return Air Smoke Detector
• High Altitude - Natural Gas - Contains orifices required • Direct Drive (3-5 ton units only) or Belt Drive Blower
for applications between 2000 and 6000 feet altitude. with High Static Drive Option
Physical Data
System power (KW) / COP 3.15 (kW) / 3.35 4.03 (kW) / 3.20 4.5 (kW) / 3.35
17ºF capacity rating (MBH) 19,000 24,900 30,000
System power (KW) / COP 2.5 (kW) / 2.2 3.48 (kW) / 2.10 4.11 (kW) / 2.14
HSPF (Btu/Watts-hr) 8.00 8.00 8.00
DIMENSIONS (inches)
Length 82-1/4 82-1/4 82-1/4
Quantity 1 1 1
CONDENSER COIL DATA
Face area (Sq. Ft.) 16.88 16.88 16.88
Rows 2 2 2
Rows 4 4 4
No. speeds 1 1 2
Number of motors 1 1 1
Frame size 56 56 56
DIRECT DRIVE EVAP FAN DATA4
Quantity 1 1 1
Capacity Performance
ZE036-072 Cooling Capacities
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
1. These capacities do not include the supply air blower motor heat. For net capacity, add motor heat,
MBh = 3.415 x kW.
Airflow Performance
ZE036-072 Side Duct Application
1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.
4. Field Supplied Drive.
1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. 1kW = BHP x 0.862.
4. Field Supplied Drive.
ZE036 - 060 (3-5 Ton Direct Drive) Side Duct
AVAILABLE EXTERNAL STATIC PRESSURE - IWG2
1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
UNIT MOTOR
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
TONNAGE SPEED
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
5 (HI) 1574 320 1530 335 1488 349 1451 363 1411 376 1374 390 1331 403 1292 417 1249 430
4 (MED/HI) 1480 263 1433 276 1389 290 1347 303 1303 316 1257 329 1208 343 1153 358 1080 374
33 3 (MED) 1332 208 1286 221 1241 234 1195 246 1146 258 1097 272 1031 288 962 303 919 313
2 (MED/LOW) 1227 171 1178 183 1129 195 1076 207 1021 220 953 235 891 248 - - - -
1 (LOW) 1075 130 992 134 930 145 858 158 - - - - - - - - - -
5 (HI) - - 2067 696 2027 714 1991 734 1953 749 1910 764 1860 769 1770 743 1621 685
4 (MED/HI) 1913 539 1877 557 1839 571 1798 585 1764 602 1721 619 1677 638 1621 653 1545 639
43 3 (MED) 1722 408 1682 426 1634 438 1597 455 1554 472 1506 490 1450 505 1404 521 1370 536
2 (MED/LOW) 1475 321 1435 335 1388 352 1359 362 1319 376 1271 393 1220 411 1186 422 1142 437
1 (LOW) 1332 223 1290 237 1232 247 - - - - - - - - - - - -
5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854
4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806
53 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748
2 (MED/LOW) 1672 408 1633 426 1586 438 1550 455 1509 472 1462 490 1408 505 1363 521 1330 536
1 (LOW) 1562 327 1529 339 1491 356 - - - - - - - - - - - -
1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance
values.
3. Side Duct application (230 Volts)
1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. 1kW = BHP x 0.862.
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
TONNAGE SPEED
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
5 (HI) 1520 320 1478 335 1438 349 1401 363 1363 376 1327 390 1286 403 1248 417 1207 430
4 (MED/HI) 1430 263 1384 276 1342 290 1302 303 1259 316 1215 329 1168 343 1114 358 1044 374
33 3 (MED) 1287 208 1242 221 1199 234 1155 246 1108 258 1060 272 997 288 930 303 889 313
2 (MED/LOW) 1185 171 1138 183 1091 195 1041 207 987 220 921 235 862 248 - - - -
1 (LOW) 1040 130 959 134 900 145 - - - - - - - - - - - -
5 (HI) - - 1995 696 1957 714 1922 734 1885 749 1844 764 1795 769 1709 743 1566 685
4 (MED/HI) 1846 539 1812 557 1776 571 1736 585 1704 602 1662 619 1619 638 1566 653 1492 639
43 3 (MED) 1662 408 1624 426 1577 438 1542 455 1501 472 1454 490 1400 505 1356 521 1323 536
2 (MED/LOW) 1566 362 1526 380 1480 391 1450 406 1411 423 1363 440 1312 455 1279 469 1235 485
1 (LOW) 1287 223 1246 237 1190 247 - - - - - - - - - - - -
5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854
4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806
53 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748
2 (MED/LOW) 1688 413 1645 432 1611 451 1575 468 1534 479 1498 497 1461 513 - - - -
1 (LOW) 1509 327 1477 339 - - - - - - - - - - - - - -
1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance
values.
3. Bottom Duct application (230 Volts)
1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.
4. Field Supplied Drive.
1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.
4. Field Supplied Drive.
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
TONNAGE SPEED
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
5 (HI) 1528 320 1485 335 1445 349 1409 363 1370 376 1334 390 1292 403 1254 417 1213 430
4 (MED/HI) 1437 263 1391 276 1349 290 1308 303 1265 316 1220 329 1173 343 1119 358 1048 374
33 3 (MED) 1293 208 1248 221 1205 234 1160 246 1113 258 1065 272 1001 288 934 303 892 313
2 (MED/LOW) 1191 171 1144 183 1096 195 1045 207 991 220 925 235 865 248 - - - -
1 (LOW) 1044 130 963 134 903 145 833 158 - - - - - - - - - -
5 (HI) - - 2007 696 1968 714 1933 734 1896 749 1855 764 1806 769 1719 743 1574 685
4 (MED/HI) 1857 539 1822 557 1786 571 1746 585 1713 602 1671 619 1628 638 1574 657 1500 676
43 3 (MED) 1672 408 1633 426 1586 438 1550 455 1509 472 1462 490 1408 505 1363 521 1330 536
2 (MED/LOW) 1475 321 1435 335 1388 352 1359 362 1319 376 1271 393 1220 411 1186 422 1142 437
1 (LOW) 1293 223 1252 237 1196 247 - - - - - - - - - - - -
5 (HI) 2245 883 2247 931 2236 950 2211 964 2171 979 2114 971 2034 940 1948 898 1855 854
4 (MED/HI) 2135 771 2116 784 2108 808 2078 826 2041 844 2004 859 1955 861 1886 843 1792 806
53 3 (MED) 2010 637 1989 656 1975 675 1938 696 1900 715 1867 730 1822 740 1784 756 1716 748
2 (MED/LOW) 1857 539 1822 557 1786 571 1746 585 1713 602 1671 619 1628 638 1574 657 1500 676
1 (LOW) 1293 223 1252 237 1196 247 - - - - - - - - - - - -
1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
3. Side Duct application (230 Volts)
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
WATTS
TONNAGE SPEED
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
5 (HI) 1476 320 1435 335 1396 349 1361 363 1324 376 1289 390 1249 403 1212 417 1172 430
4 (MED/HI) 1388 263 1344 276 1303 290 1264 303 1222 316 1179 329 1134 343 1082 358 1013 374
33 3 (MED) 1250 208 1206 221 1164 234 1121 246 1076 258 1029 272 968 288 903 303 863 313
2 (MED/LOW) 1151 171 1105 183 1060 195 1010 207 958 220 895 235 - - - - - -
1 (LOW) 1009 130 932 134 874 145 - - - - - - - - - - - -
5 (HI) 1975 636 1937 696 1900 714 1866 734 1831 749 1791 764 1743 769 1660 743 1520 685
4 (MED/HI) 1793 539 1759 557 1724 571 1685 585 1654 602 1613 619 1572 638 1520 657 1449 676
43 3 (MED) 1614 408 1577 426 1532 438 1497 455 1458 472 1412 490 1360 505 1317 521 1285 536
2 (MED/LOW) 1450 321 1384 335 1338 352 1311 362 1274 376 1226 393 1177 411 1144 422 1098 437
1 (LOW) 1250 223 1210 237 1156 247 - - - - - - - - - - - -
5 (HI) 2166 883 2169 931 2158 950 2134 964 2095 979 2040 971 1963 940 1881 898 1791 854
4 (MED/HI) 2060 771 2042 784 2035 808 2006 826 1970 844 1934 859 1888 861 1821 843 1730 806
53 3 (MED) 1940 637 1920 656 1907 675 1870 696 1834 715 1802 730 1759 740 1722 756 1657 748
2 (MED/LOW) 1830 413 1759 432 1724 451 1685 468 1654 479 1613 497 1572 513 - - - -
1 (LOW) 1250 327 1210 339 - -
1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil and 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
3. Bottom Duct application (230 Volts)
Drive Selection
1. Determine side or bottom supply air duct application.
2. Determine desired airflow.
3. Calculate or measure the amount of external static pressure.
4. Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance table. (Linear
interpolation may be necessary.)
5. Noting the RPM and BHP from step 4, locate the appropriate motor and/or drive on the RPM selection table.
6. Review the BHP compared to the motor options available. Select the appropriate motor and/or drive.
7. Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the chosen motor.
8. Determine turns open to obtain the desired operation point.
Example
1. 2200 CFM
2. 1.6 iwg
3. Using the supply air blower performance table below, the following data point was located: 1478 RPM & 1.82 BHP.
4. Using the RPM selection table below, Size X and Model Y is found.
5. 1.82 BHP exceeds the maximum continuous BHP rating of the 1.5 HP motor. The 2 HP motor is required.
6. 1478 RPM is within the range of the 2 HP drive.
7. Using the 2 HP motor and drive, 2.5 turns open will achieve 1478 RPM.
1.100
1.050
1.000
Sea Level
0.950
Correction Factor
1000 ft
0.900 2000 ft
3000 ft
0.850
4000 ft
0.800 5000 ft
6000 ft
0.750 7000 ft
8000 ft
0.700
9000 ft
10000 ft
0.650
0.600
40 50 60 70 80 90 100
Air Temperature (ºF)
Sound Performance
Electrical Data
Without Powered Convenience Outlet
ZE036-072 (Belt Drive)
OD Fan Supply Pwr Max
Compressors
Motors Blower Conv Electric Heat Option Fuse2/
Size (each) MCA1
Volt (each) Motor Outlet Breaker3
(Tons) (Amps)
Size
RLA LRA MCC FLA FLA FLA Model kW Stages Amps
(Amps)
NONE - - - 28.3 35
E05 4 1 19.2 32.4 40
E07 5.6 1 26.9 42 45
208-1-60 4 15.4 83.9 24 2.3 6.7 0
E10 8 1 38.5 56.5 60
E15 11.9 2 57.2 79.9 80
E20 15.9 2 76.4 103.9 110
NONE - - - 28.3 35
E05 5.3 1 22.1 36 40
E07 7.5 1 31.2 47.4 50
230-1-60 4 15.4 83.9 24 2.3 6.7 0
E10 10.6 1 44.2 63.6 70
E15 15.9 2 66.2 91.2 100
E20 21.2 2 88.3 118.8 125
NONE - - - 19.6 25
E05 4 1 11.1 19.6 25
E07 5.6 1 15.5 24.8 30
208-3-60 10.4 73 16.3 2.3 4.3 0
E10 8 1 22.2 33.1 35
036
E15 11.9 2 33 46.7 50
(3.0)
E20 15.9 2 44.1 60.5 70
NONE - - - 19.6 25
E05 5.3 1 12.7 21.3 30
E07 7.5 1 18 27.9 30
230-3-60 10.4 73 16.3 2.3 4.3 0
E10 10.6 1 25.5 37.2 40
E15 15.9 2 38.2 53.2 60
E20 21.2 2 51 69.1 70
NONE - - - 10.6 15
E07 6.8 1 8.2 12.8 15
460-3-60 5.8 38 9 1.3 2.1 0 E10 10.1 1 12.1 17.8 20
E15 13.6 2 16.4 23.1 25
E20 19.5 2 23.5 31.9 35
NONE - - - 8.2 15
E10 10.6 1 10.2 15.1 20
575-3-60 4.2 36.5 5.9 1.3 1.9 0
E15 15.9 2 15.3 21.5 25
E20 21.2 2 20.4 27.9 30
NONE - - - 33.5 45
E05 4 1 19.2 33.5 45
E07 5.6 1 26.9 42 50
208-1-604 19.6 130 30.5 2.3 6.7 0
E10 8 1 38.5 56.5 60
E15 11.9 2 57.2 79.9 80
E20 15.9 2 76.4 103.9 110
NONE - - - 33.5 45
E05 5.3 1 22.1 36 45
E07 7.5 1 31.2 47.4 50
230-1-604 19.6 130 30.5 2.3 6.7 0
E10 10.6 1 44.2 63.6 70
E15 15.9 2 66.2 91.2 100
E20 21.2 2 88.3 118.8 125
NONE - - - 23.7 30
E05 4 1 11.1 23.7 30
E07 5.6 1 15.5 24.8 30
208-3-60 13.7 83.1 21.4 2.3 4.3 0
E10 8 1 22.2 33.1 35
048
E15 11.9 2 33 46.7 50
(4.0)
E20 15.9 2 44.1 60.5 70
NONE - - - 23.7 30
E05 5.3 1 12.7 23.7 30
E07 7.5 1 18 27.9 35
230-3-60 13.7 83.1 21.4 2.3 4.3 0
E10 10.6 1 25.5 37.2 40
E15 15.9 2 38.2 53.2 60
E20 21.2 2 51 69.1 70
NONE - - - 11.1 15
E07 6.8 1 8.2 12.8 15
460-3-60 6.2 41 9.7 1.3 2.1 0 E10 10.1 1 12.1 17.8 20
E15 13.6 2 16.4 23.1 25
E20 19.5 2 23.5 31.9 35
NONE - - - 8.9 15
E10 10.6 1 10.2 15.1 20
575-3-60 4.8 33 7.5 1.3 1.9 0
E15 15.9 2 15.3 21.5 25
E20 21.2 2 20.4 27.9 30
Compressors
OD Fan Supply Pwr Max Fuse2/
Size (each)
Motors Blower Conv Electric Heat Option MCA1 Breaker3
Volt
(Tons) (each) Motor Outlet (Amps) Size
RLA LRA MCC FLA FLA FLA Model kW Stages Amps (Amps)
NONE - - - 38.9 50
E05 4 1 19.2 62.9 70
E07 5.6 1 26.9 72.5 80
208-1-60 16.7 109 26 1.3 6.7 10
E10 8 1 38.5 87 90
E15 11.9 2 57.2 110.4 125
E20 15.9 2 76.4 134.4 150
NONE - - - 38.9 50
E05 5.3 1 22.1 66.5 70
E07 7.5 1 31.2 77.9 80
230-1-60 16.7 109 26 1.3 6.7 10
E10 10.6 1 44.2 94.1 100
E15 15.9 2 66.2 121.7 125
E20 21.2 2 88.3 149.3 150
NONE - - - 29.6 40
E05 4 1 11.1 43.5 50
E07 5.6 1 15.5 49 50
208-3-60 11.2 88 17.5 1.3 4.3 10
E10 8 1 22.2 57.4 60
036
E15 11.9 2 33 70.9 80
(3.0)
E20 15.9 2 44.1 84.8 90
NONE - - - 29.6 40
E05 5.3 1 12.7 45.5 50
E07 7.5 1 18 52.2 60
230-3-60 11.2 88 17.5 1.3 4.3 10
E10 10.6 1 25.5 61.5 70
E15 15.9 2 38.2 77.4 80
E20 21.2 2 51 93.3 100
NONE - - - 14.8 20
E07 6.8 1 8.2 25 25
460-3-60 5.5 43.2 7.7 0.8 2.1 5 E10 10.1 1 12.1 30 30
E15 13.6 2 16.4 35.2 40
E20 19.5 2 23.5 44.1 45
NONE - - - 11.3 15
E10 10.6 1 10.2 24.1 25
575-3-60 3.8 34 6 0.8 1.9 4
E15 15.9 2 15.3 30.5 35
E20 21.2 2 20.4 36.8 40
ZE036-060 - Without Powered Convenience Outlet (Belt Drive Single Phase Gas Heat)
OD Fan Supply Pwr Max
Compressors
Motors Blower Conv Electric Heat Option Fuse2/
Size (each) MCA1
Volt (each) Motor Outlet Breaker3
(Tons) (Amps)
Size
RLA LRA MCC FLA FLA FLA Model kW Stages Amps
(Amps)
036 208-1-60 15.4 83.9 24 2.3 17.4 None - - - 39.5 50
(3) 230-1-60 15.4 83.9 24 2.3 17.4 None - - - 39.5 50
ZE036-060 - With Powered Convenience Outlet (Belt Drive Single Phase Gas Heat)
OD Fan Supply Pwr Max Fuse2/
Compressors
Size
(each)
Motors Blower Conv Electric Heat Option MCA1 Breaker3
Volt
(Tons) (each) Motor Outlet (Amps) Size
RLA LRA MCC FLA FLA FLA Model kW Stages Amps (Amps)
CONTROL
THERMOSTAT TERMINAL
TERMINALS BLOCK
W1
W1
W2
W2
1 Y1
Y1 Y2
Y2 G
OCC
G
X
R R
3
C SD-24
C
RC
4
Smoke
OCC Detector
5
TERMINALS ON A
R Jumper
2
LIMITED NUMBER
OF THERMOSTATS SD
SD 24 VAC
Class 2
1 Second stageŚĞĂƟŶŐŶot required on single stage heĂƟŶg units. C
2 Jumper is required if there is no Smoke Detector circuit.
3 Jumper is required for any coŵďŝŶĂƟŽŶ of R, RC, or RH.
4 OCC is an output from the thermostat to indicate the Occupied ĐŽŶĚŝƟon.
5 X is an input to the thermostat to display Error Status condiƟons.
C SD-24
C
Smoke
RC Detector
4
OCC C
5
X 24V 24 VAC
Class 2
R
1 Second stageŚĞĂƟŶŐŶot required on single stage heĂƟŶg units.
2 Jumper is required if there is no Smoke Detector circuit.
3 Jumper is required for any coŵďŝŶĂƟŽŶ of R, RC, or RH.
4 OCC is an output from the thermostat to indicate the Occupied ĐŽŶĚŝƟon.
5 X is an input to the thermostat to display Error Status condiƟons.
C SD-24
C
Smoke
RC Detector
4
OCC C
5
X 24V 24 VAC
Class 2
R
1 Second stageŚĞĂƟŶŐŶot required on single stage heĂƟŶg units.
2 Jumper is required if there is no Smoke Detector circuit.
3 Jumper is required for any coŵďŝŶĂƟŽŶ of R, RC, or RH.
4 OCC is an output from the thermostat to indicate the Occupied ĐŽŶĚŝƟon.
5 X is an input to the thermostat to display Error Status condiƟons.
C D
B C
A A E
B
D Front F Front
Y
X
FRONT
LEFT
ZE036-072
Size Weight (lbs.) Center of 4 point Load Location (lbs.) 6 point Load Location (lbs.)
(Tons) Shipping Operating X Y A B C D A B C D E F
036
475 470 34.5 18.25 111 80 117 162 78 62 51 74 91 114
(3)
048
603 598 36 18.5 139 108 154 198 96 81 69 98 116 137
(4)
060
637 632 37.5 18.2 139 117 171 204 96 85 76 111 124 140
(5)
072
670 665 35.5 17.75 150 114 173 228 104 86 72 111 132 160
(6)
XN036-060
Size Weight (lbs.) Center of Gravity 4 point Load Location (lbs.) 6 point Load Location (lbs.)
(Tons) Shipping Operating X Y A B C D A B C D E F
036
615 610 38.3 18.75 136 119 165 190 93 85 77 108 118 129
(3)
048
621 616 38.2 18.4 135 117 169 195 92 84 76 110 121 133
(4)
060
625 620 38.6 18 132 117 174 197 90 83 76 114 123 134
(5)
ZE/XN036-072 Unit Accessory Weights 1. Weight given is for the maximum heater size available
(30KW).
Weight (lbs.)
Unit Accessory 2. Weight given is for the maximum number of tube heat
Shipping Operating exchangers available (5 tube).
Economizer 55 50
Power Exhaust 55 50
Electric Heat1 28 28
Gas Heat2 70 70
27-1/2 1-5/8
27-1/2
19-3/4
19-1/2 44-7/8
Detail “A”
27-1/2 7-1/4
27-1/2 10-1/4
19-1/8 3-1/2
8-1/4
“A” 44-7/8
Dimension “A”
Fixed
Outdoor 12
Air Damper Detail “B”
Motorized 16-1/2
Damper
UNIT BASE
3.75”
INSULATION