Pleated Panel Filter for Meeting ASHRAE Minimum Recommendations

The Camfil AP-Thirteen SC extended surface pleated filter


offers filtration for applications that have 1", 2" or 4" deep
filter tracks. The AP-Thirteen SC is a MERV 13 filter when
evaluated per ASHRAE Standard 52.2 and meets the
requirements for minimum filtration efficiency as published in
LEED manuals for new or existing buildings. The AP-Thirteen
SC may reduce the size of the HVAC system, saving
valuable mechanical area floor space. It also simplifies
the upgrading of in-place systems, allowing existing units
to meet LEED requirements without major equipment
modification.

Standard pleated filters remove nuisance dusts, lint and


contaminants associated with staining, and are primarily
designed to protect equipment and act as prefilters. As a
stand-alone filter, the AP-Thirteen SC will perform these tasks
and removes sub-micron particles, defined as lung-damaging
by cognizant authorities. The AP-Thirteen SC, according to
filtration application design manuals, can be used as the
only filter for special process areas, electrical shops, paint
shops, average general offices and laboratories. Other
applications include analytical laboratories, electronics
shops, drafting areas, conference rooms, and above-
average general offices.

High efficiency filtration to Built for needs of today’s HVAC systems, the AP-Thirteen SC:
achieve MERV 13 minimum
recommendations in 1", 2" or 4" • Has 10 pleats per linear foot on the 2-inch model.

deep pleated panel applications. • Includes a synthetic fiber blend with a unique media
loft that provides high efficiency ASHRAE MERV 13
performance with good dust-holding capacity.
• Has an expanded metal backing treated for corrosion
resistance and bonded to the downstream side of the
media to prevent media oscillation.
• Has a high wet-strength beverage board frame that
creates a rigid and durable filter pack. The AP-
Thirteen SC will not bow or deflect.

The above chart shows resistance to airflow up to 2500 CFM.

www.ca mf il.co m Camfil | AP-Thirteen SC / 1


AP-Thirteen SC
Pleated Panel Filter for Meeting ASHRAE Minimum Recommendations

Performance Data
1" Nominal Depth 2" Nominal Depth 4" Nominal Depth
∆p of 0.49" w.g. ∆p of 0.51" w.g. ∆p of 0.37" w.g.
Airflow Media Airflow Media Airflow Media
Part Nominal Size Part Nominal Size Part Nominal Size
Capacity Area Capacity Area Capacity Area
Number (inches) Number (inches) Number (inches)
(cfm) (sq ft) (cfm) (sq ft) (cfm) (sq ft)
406930003 25X20X1 1210 6.8 406931004 25X16X2 1380 8.4 406950006 25X20X4 1730 19.6
406930002 20X20X1 970 5.4 406931002 20X20X2 1380 8.4 406950008 24X18X4 1500 16.9
406930010 24X16X1 930 5.1 406931003 25X20X2 1730 10.6 406950002 24X12X4 1000 11.1
406930029 20X30X1 1450 8.1 406931001 20X16X2 1110 6.7 406950004 20X16X4 1110 12.4
406930001 20X16X1 770 4.3 406931005 24X24X2 2000 12.1 406950005 25X16X4 1380 15.6
406930004 25X16X1 970 5.4 406931007 24X20X2 1660 10.1 406950003 20X20X4 1380 15.6
406930030 18X14X1 610 4.2 406931008 24X18X2 1500 9.1 406950007 24X20X4 1660 16.9
406930005 24X24X1 1400 7.8 406931006 24X12X2 1000 5.9 406950001 24X24X4 2000 11.1
406930006 20X14X1 680 3.7 406931023 20X30X2 2080 12.7 406950009 24X16X4 1330 14.9
406930007 24X20X1 1160 6.5 406931012 24X16X2 1330 8.1 406950010 16X25X4 1380 15.6
406930008 20X15X1 720 4 406931017 20X15X2 1040 10.6 406950011 20X24X4 1660 18.8
406930009 24X12X1 700 3.8 406931010 20X14X2 970 5.8 406950012 20X25X4 1730 19.6
406930011 25X14X1 850 4.7 406931009 25X18X2 1560 9.5 DATA NOTES:
406930012 20X10X1 480 2.6 406931020 16X25X2 1380 8.4 • To establish a schedule for filter change, record initial
pressure drop when installed, order filters for change
406930013 25X25X1 1510 8.5 406931022 20X25X2 1730 10.6
when pressure drop has doubled and service unit when
406930014 25X18X1 1090 6.1 406931011 25X14X2 1210 7.3 replacements are available.
406930016 16X16X1 620 3.4 406931013 25X25X2 2170 13.3 • 1.0” w.g. recommended maximum final resistance. System
design may dictate a lower change-out point.
406930018 20X12X1 580 3.2 406931015 20X10X2 690 4.1
• The AP-Thirteen SC filter is classified by Underwriters
406930019 20X18X1 870 4.8 406931016 16X16X2 880 5.3 Laboratories as UL 900.
406930020 22X22X1 1170 6.5 406931017 20X12X2 830 5 • Maximum operating temperature 175° F. (70° C).
406930021 24X10X1 580 3.2 406931018 20X18X2 1250 7.6 • Tolerances in accordance with ARI Standard 850
406930022 25X10X1 600 3.3 406931019 25X15X2 1300 7.9
406930023 25X12X1 720 4 406931021 20X24X2 1660 10.1
406930024 25X15X1 910 5
406930026 24X14X1 810 4.5 2.2 – An expanded metal backing treated for corrosion resistance, shall be bonded to the downstream
406930027 16X12X1 460 2.5 side of the media to prevent media oscillation.
406930028 24X18X1 1050 5.8
2.3 - An enclosing frame, of high wet-strength beverage board shall provide a rigid and durable enclosure.
The frame shall be bonded to the media to prevent air bypass, and include integral diagonal support
Specifications members on the air entering and air existing side to maintain uniform pleat spacing in varying airflows.
1.0 General

© Copyright Camfil 0123


3.0 Performance
1.1 - Air filters shall be medium efficiency ASHRAE 3.1 - The filter shall have a Minimum Efficiency Reporting Value of MERV 13 when evaluated under the
pleated panels consisting of a synthetic media guidelines of ASHRAE Standard 52.2.
blend, media support grid, and enclosing frame.
3.2 - Initial resistance to airflow shall not exceed 0.49”, 0.51” or 0.37” w.g. at an airflow of 350 or
1.2 - Sizes shall be noted on drawings or other 500 fpm on 1”, 2” or 4” deep models respectively.
supporting materials.
3.3 - The filter shall be classified by Underwriters Laboratories as UL Class 900.
2.0 Construction
3.4 - Manufacturer shall provide evidence of facility certification to ISO 9001:2015.
2.1 - Filter media shall be a synthetic blend,
lofted to a uniform depth, and formed into a Supporting Data - Provide product test reports for each listed efficiency including all details as
uniform radial pleats. There shall be at least 12, prescribed in ASHRAE Standard 52.2.
10 or 9 pleats per linear foot for 1” deep, 2” Filter shall be Camfil AP-Thirteen SC or equal.
deep or 4” deep filters respectively.

For detailed specifications and exact height, width and depth of each size, consult your local
Camfil Distributor, Representative or AP-Thirteen SC. Camfil has a policy of uninterrupted research,
development and product improvement. We reserve the right to change designs and specifications
without notice.

Camfil | 1 North Corporate Drive, Riverdale, NJ 07457 | Tel: (973) 616-7300