International Journal of Recent Technology and Engineering (IJRTE)

ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019

A Nonlinear Static Research on A G+5 Storey


Existing RC Structure Under Seismic
Loading
V. Sai Kiran Kumar, C. Mahalingam, M. Shiva Rama Krishna

Abstract: A six-story reinforced concrete structure area to a


seismic hazard can be analyzed; as soon as the member has
yielded, the plastic hinge will likely be used to symbolize the mode
of failure in the beams and columns. The pushover analysis is
carried out on constructing utilizing an identical static process
from ETABS-2016 and IS 1893-2016. The analysis is regulated
through efficiency-situated warmness engineering legal
guidelines, even as an inelastic structural evaluation is combined
with seismic hazard to calculate the expected seismic
performance of the structure. The building's basis shear v / s roof
strain curve referred to as the pushover curve is an enormous
consequence of pushover evaluation; nonlinear dynamic Figure: 1 Description of performance-based design
evaluation is carried out in both respects (X & Y). Default hinge
facets to be had in precise packages are built-in for every member
in step with FEMA-440(Federal Emergency management
A system is usually built in a powerful column and soft
agency) and ATC-40(applied technology Council) for every beam concept, but the principle is obeyed in frequent
member. techniques such as tiny constructions to face the
Keywords: Plastic hinge, pushover analysis, ETABS, base implications.A framework can achieve a stronger outcome
shear, FEMA-356, FEMA-440, ATC-40. during the incident based on the ATC – 40 and FEMA-440
code manual.
I. INTRODUCTION MehmetInel and HayriBaytanOzmen (2006) User-defined
The seismic impact will annihilate a building and will nonlinear hinge characteristics and standard hinge
also lead to several problems such as tsunamis liquefaction characteristics as per ATC 40 and FEMA-440[2] were used
of soil, landslides etc. As per IS: 1893- 2016 code and to perform pushover assessment on a 4 and 7-story
seismal design regulations which were recently released construction. The fundamental purpose of this paper is to
were in use effective ever since. For the alternate structures investigate the double differences in pushover analysis
of the sensing of buildings, this code gives minimum loads outcome because of default and consumers are defending
required [1]. Majority of engineers adopt linear analysis nonlinear component aspects.
technique as it is easy while computing & analyzing the
structure. This method resorts uses of response reduction
parameter for the entire structure to give a nonlinear
response of the structure.The building standards such as
ATC and FEMA have applied on the design criteria based
on the performance based, which will estimate the nonlinear
response of the building.An insight into the structural
elements that regulate efficiency during serious earthquakes
can be provided in this assessment. During layout
earthquake movement, a thermal deficient construction will
be exposed to inelastic intervention. It is the only way to Figure: 2 Force Deformation curve
portray the structure's real behavior during the
earthquake.The building changes the structure's conduct Table 1: Performance of Structure damage level
during the earthquake as shown below.
Performance stages Statements
Immediate Occupancy Little damage, very big parts drop.
Substantial to severe harm, big
and widespread splits in all
Life Safety
employees and non-structural
Revised Manuscript Received on July 10, 2019. components entity malfunction.
V. Sai Kiran Kumar, P.G Student, Vignan’s University, Guntur,
Andhra Pradesh India. (Email: [email protected])
C. Mahalingam, Assistant professor, Vignan’s University, Guntur,
Andhra Pradesh India. (Email: [email protected])
M. Shiva Rama Krishna, Assistant professor, Vignan’s University,
Guntur, Andhra Pradesh India. (Email: [email protected])

Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1078 & Sciences Publication
A NONLINEAR STATIC RESEARCH ON A G+5 STOREY EXISTING RC STRUCTURE UNDER SEISMIC
LOADING
Very massive harm, big
displacement, very little rigidity
and resistance but execute
Preventing Failure
loading column and wall
bearings, complete destruction
or near complete failure.

II. STRUCTURAL MODELING:


AutoCAD drafts all beams and column members
imported into ETABS. The loads and properties are assigned
to the considered reinforced concrete structure. The plan
considered as described below as shown fig 3. The overall
dimensions of the plan are 70.27m×60.37m. In this existing
RC, a building is used as a commercial complex purpose.
I) Description of building:
a. Concrete grade: M30,
b. Steel grade: Fe-415 N/mm2
Table: 2 Cross Section dimensions
Member Width(mm) Depth(mm) Figure: 4 Diagram of methodology stream
B1 300 500
B2 350 750 IV. NONLINEAR STATIC ANALYSIS:
C1 300 850  This evaluation is theoretically right, but very difficult
C2 300 650 and not suitable for all models.
 Structural engineering practice nowadays utilizes a
II) Seismic Coefficients
nonlinear static evaluation, a replacement technique for
S.No Parameters Code solving the issue.
Provisions  The lateral strain may portray the range of base
1 Type of Structure RCC distortion caused by earthquake.
2 Nature of Building University  The output generates a static pushover curve plotting a
Building deflection parameter based on force.
3 Damping of Concrete 5%  Basically split into three kinds in this study
a. Target displacement
4 Importance Factor 1.5
b. Capacity spectrum method
5 Response Reduction Factor 5 c. Coefficient method.
6.a Existing Seismic Zone III  These three methods are used during the earthquake to
6.b Considered Seismic Zone IV determine the effectiveness of the building and to
7 Earthquake force in X direction achieve very pleasantly accurate results.
8 Earthquake force in Y direction 4.1 Plastic Hinge:
 The plastic hinge is the primary component of the
framework when each load is given to the structural
parts.
 In this structure, each participant assigned a hold of 5%
of each joint (if the structure is periodic in a type).
 If beams and pillars are not of the same length, 5% of
the joint was not used by each structural component.
 We need to use ASCE-41-13 code manual to assign the
handles.
 Hinge shows the member's breakdown and the
Figure: 3 AutoCAD Structural plan
member's place.
III. METHODOLOGY: 4.2 Building Performance level:
The present work is to be taught the seismic behaviour of  Construction that primarily performs three requirements
a G+5 storey RCC building having diaphragm discontinuity i.e.
and geometrical irregularities under pushover analysis.The  Immediate occupancy level
methodology, which is performed, is briefly described  Life safety level
beneath.  Collapse prevention

Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1079 & Sciences Publication
International Journal of Recent Technology and Engineering (IJRTE)
ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019

 In the earthquake motion, these three play a significant


role.
 Resisting lateral distortion, as shown below, to be
verified against the normal deformation boundaries.
Table: 3 Deformation limits
State of Damage Chord Rotation Capacity
Immediate Occupancy (IO) Θy + 10% of (Θu-Θy)
Life Safety (LS) Θy + 60% of (Θu-Θy)
Collapse Prevention (CP) Θy + 90% of (Θu-Θy)
Figure: 6.b Ʌ - bracing 3D Structure
V. ANALYTICAL DESIGN:
VI. FINAL RESULTS & DISCUSSIONS:
 As shown in figure 5, a 3D design was developed to
handle the corresponding static assessment and  This building's capacity curve is shown in Fig. 7. This
pushover evaluation. curve reflects worldwide behaviour, stiffness, and
 Compared to nonlinear static assessment, equivalent plasticity.
 Capacity range technique offers accurate and simple
static assessment has a lower displacement.
process efficiency.
 After gradually implementing it to the current
 The capability range and request ratio curves this
construction (deemed building / structure), some
phenomenon called the quality point.
portion of the structure will fail.
 Considered the current Zone-III situation structure but  When the supply curve and capability range meet at a
its shift from Zone-III to Zone-IV for this initiative. stage at which point the power of the framework
(quality point) is indicated.
 Because the house can survive in Zone IV situation in
that situation, there is no question that in Zone–IV it  X-bracings have a morebase strain compared to the
can withstand. foundation strain in both bracings (X, some-bracings).
 The construction methods move aside after completing  Now we can see the outcomes of the hinge as shown in
the picture below, which shows the place of the member
all preliminary measures to show the path of the
load.
earthquake.

Figure: 5 3D Structural Model

 New support for withstands more earthquake (seismic) Figure: 7.a Capacity curve
charging to this framework.
 Usually, different kinds of bracings are used, here two
kinds are used.
i. X – bracings
ii. Ʌ - bracings
 As shown in Figure 6.a, 6.b, these two are styled and
layout regarded.

Fig: 7.b Performance point

Figure: 6.aX – bracing 3D model

Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1080 & Sciences Publication
A NONLINEAR STATIC RESEARCH ON A G+5 STOREY EXISTING RC STRUCTURE UNDER SEISMIC
LOADING

Max storey shear:


For the duration of the earthquake, the peak floor shear
Fig: 7.c Hinge locations in Structure occurs as follows beneath fig.

Max. Storey displacement:


The highest storage limit for linear static technique is
when the earthquake force is transferred to the structure's X
& Y coordinates as shown in the graphics below.

Fig: 8 Storey Shear


Table:4 Shear Force in table representation
Load
FX FY MX MY MZ
Case
(kN) (kN) (kN-m) (kN-m) (kN-m)
Live 0 0 1365455 -1411225 9.48E-06
Max. Storey Drift:
EQX +ve -7637.47 -5.5E-07 2.61E-05 -154218 250530.8
The max storey drift for equivalent static method is when EQY +ve 0 -5881.29 118757 -4E-06 -203659
the seismic force is applied on both directions are EQX-ve -7637.47 -5.5E-07 2.61E-05 -154218 250530.8
represented as follows: EQY-ve 0 -5881.29 118757 -4E-06 -203659
Table: 5 Base shear and Roof displacement at performance levels
Roof
Base
Steps Displacement A-B B-C C-D D-E >E A-IO B-LS C-CP >CP Total
force(kN)
(mm)
1 0.284 0 6524 0 0 0 0 6524 0 0 0 6524
2 0.841 12649.2226 6522 2 0 0 0 6524 0 0 0 6524
3 1.131 17929.5128 6484 40 0 0 0 6524 0 0 0 6524
4 1.936 23503.3939 6328 196 0 0 0 6522 0 0 2 6524
5 4.123 30082.7139 6142 382 0 0 0 6522 0 0 2 6524
6 6.013 33360.7045 6012 512 0 0 0 6520 0 0 4 6524
7 6.013 33359.3023 6012 512 0 0 0 6520 0 0 4 6524

8 6.014 33361.0818 6012 512 0 0 0 6520 0 0 4 6524

9 6.018 33367.3647 6012 512 0 0 0 6520 0 0 4 6524

10 6.018 33366.7351 6012 512 0 0 0 6520 0 0 4 6524

Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1081 & Sciences Publication
International Journal of Recent Technology and Engineering (IJRTE)
ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019

VII. CONCLUSION:
In this study, the primary job is to use a nonlinear static
assessment to obtain the seismic efficiency of construction.
This study's conclusion can be described as below.
 Pushover analysis could be a comparatively easy
method of monitoring the building's nonlinear
behaviour.
 The technique of capability range shows the building's
complete power against collapse, which is large and
there is an adequate supply of power and displacement.
 The technique of capability range shows the building's
complete power against collapse, which is large and
there is an adequate supply of power and displacement.
[7].
 The final conclusion for this project linear static method
is good enough to only low to medium height buildings
with regular confirmation.
 The considered model of building resists major seismic
forces.
 Analysis of pushover could be a comparatively easy
way to track the building's nonlinear behavior.
 A critical reason is found, that's the immediate
occupancy level condition. In that area structure have
minor visible cracks obtain.
 The structure can behave resisting major earthquake
forces throughout the imposed seismic excitation.
 Inverted ‘v’ (Ʌ) is an inexpensive and excellent lateral
load resistant to compare with X-bracing design.

REFERENCES:
1. IS 1893–2016, "Indian Standard Criteria for Resistant Design
of Earthquake Structures: General Supply and Building,"
Indian Standards Bureau, New Delhi.
2. MehmetInel and HayriBaytanOzmen, "Nonlinear Analysis of
Reinforced Concrete Buildings Effects of Plastic Hinge
Properties" Engineering Structures, Vol.28, 2006, pp. 1494-
1502.
3. Golghate Kavita, Baradiya Vijay and Sharma Amit,
"Reinforced Concrete Building Pushover Analysis of 4
Storey"International Journal of Latest Trends in Engineering
and Technology, Vol. 2, May 2013, pp. 80-84.
4. "Nonlinear Structural Analysis for Seismic Design," A Guide
for Practical Engineers, National Standards and Technology
Institute, Gregory G. Deierlein, Andrei M. Reinhorn, Michael
R. Willford.
5. ATC40-"concrete building seismic assessment and
retrofitting.
6. 'FEMA 356 (2000) ' Seismic Building Rehabilitation Standard
and Commentary, ' Federal Emergency Management Agency,
Washington, DC, USA.
7. R. A. Hakim, S. A. Ashour, M. S. Alama. "RC Building
Seismic Assessment According to ATC 40, FEMA 356 and
FEMA 440," Arab Journal for Science and Engineering, 2014.
8. FEMA-440, Federal Emergency Management Agency,
Applied Technology Council (ATC-55 Project) 201 Redwood
Shores Parkway, Suite240, Redwood City, California, Federal
Emergency Management Agency Washington D.C.

Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1082 & Sciences Publication