Structure Under Seismic Loading
Structure Under Seismic Loading
Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1078 & Sciences Publication
A NONLINEAR STATIC RESEARCH ON A G+5 STOREY EXISTING RC STRUCTURE UNDER SEISMIC
LOADING
Very massive harm, big
displacement, very little rigidity
and resistance but execute
Preventing Failure
loading column and wall
bearings, complete destruction
or near complete failure.
Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1079 & Sciences Publication
International Journal of Recent Technology and Engineering (IJRTE)
ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019
New support for withstands more earthquake (seismic) Figure: 7.a Capacity curve
charging to this framework.
Usually, different kinds of bracings are used, here two
kinds are used.
i. X – bracings
ii. Ʌ - bracings
As shown in Figure 6.a, 6.b, these two are styled and
layout regarded.
Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1080 & Sciences Publication
A NONLINEAR STATIC RESEARCH ON A G+5 STOREY EXISTING RC STRUCTURE UNDER SEISMIC
LOADING
Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1081 & Sciences Publication
International Journal of Recent Technology and Engineering (IJRTE)
ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019
VII. CONCLUSION:
In this study, the primary job is to use a nonlinear static
assessment to obtain the seismic efficiency of construction.
This study's conclusion can be described as below.
Pushover analysis could be a comparatively easy
method of monitoring the building's nonlinear
behaviour.
The technique of capability range shows the building's
complete power against collapse, which is large and
there is an adequate supply of power and displacement.
The technique of capability range shows the building's
complete power against collapse, which is large and
there is an adequate supply of power and displacement.
[7].
The final conclusion for this project linear static method
is good enough to only low to medium height buildings
with regular confirmation.
The considered model of building resists major seismic
forces.
Analysis of pushover could be a comparatively easy
way to track the building's nonlinear behavior.
A critical reason is found, that's the immediate
occupancy level condition. In that area structure have
minor visible cracks obtain.
The structure can behave resisting major earthquake
forces throughout the imposed seismic excitation.
Inverted ‘v’ (Ʌ) is an inexpensive and excellent lateral
load resistant to compare with X-bracing design.
REFERENCES:
1. IS 1893–2016, "Indian Standard Criteria for Resistant Design
of Earthquake Structures: General Supply and Building,"
Indian Standards Bureau, New Delhi.
2. MehmetInel and HayriBaytanOzmen, "Nonlinear Analysis of
Reinforced Concrete Buildings Effects of Plastic Hinge
Properties" Engineering Structures, Vol.28, 2006, pp. 1494-
1502.
3. Golghate Kavita, Baradiya Vijay and Sharma Amit,
"Reinforced Concrete Building Pushover Analysis of 4
Storey"International Journal of Latest Trends in Engineering
and Technology, Vol. 2, May 2013, pp. 80-84.
4. "Nonlinear Structural Analysis for Seismic Design," A Guide
for Practical Engineers, National Standards and Technology
Institute, Gregory G. Deierlein, Andrei M. Reinhorn, Michael
R. Willford.
5. ATC40-"concrete building seismic assessment and
retrofitting.
6. 'FEMA 356 (2000) ' Seismic Building Rehabilitation Standard
and Commentary, ' Federal Emergency Management Agency,
Washington, DC, USA.
7. R. A. Hakim, S. A. Ashour, M. S. Alama. "RC Building
Seismic Assessment According to ATC 40, FEMA 356 and
FEMA 440," Arab Journal for Science and Engineering, 2014.
8. FEMA-440, Federal Emergency Management Agency,
Applied Technology Council (ATC-55 Project) 201 Redwood
Shores Parkway, Suite240, Redwood City, California, Federal
Emergency Management Agency Washington D.C.
Published By:
Retrieval Number: B12020782S319/19©BEIESP Blue Eyes Intelligence Engineering
DOI : 10.35940/ijrte.B1202.0782S319 1082 & Sciences Publication