Netlink Configuration Utility Manual
Netlink Configuration Utility Manual
Table of Contents
NetLink Configuration Utility 1
Table of Contents 2
Overview 3
Getting Started 4
Refresh List 5
Parameter Settings 7
Parameter Download 9
Advanced Profibus Parameter Descriptions 10
Firmware 12
Troubleshooting 16
Error Codes 16
Index 17
www. kepware.com
3 NetLink Configuration Utility
CONTENTS
Overview
What is the NetLink Configuration Utility?
Getting Started
How do I use the NetLink Configuration Utility?
Troubleshooting
What if something isn't what I expect?
Error Codes
What are the messages generated by the utility?
Overview
The NetLink device is a gateway from Ethernet to S7 MPI, in bus connector format. The NetLink
Configuration Utilityy application provides:
Navigation
The following Device menu items are available in the NetLink Configuration Utility.
Set Set temporary IP address for subsequent downloads of Parameter Set Temporary IP
Temporary IP Settings and Firmware. Address
www. kepware.com
NetLink Configuration Utility 4
Getting Started
This tutorial provides instructions for scanning the network for NetLink devices, setting a temporary IP
address, and downloading parameter settings to the device (including a permanent IP address).
1. Select Device | Refresh List. This cause a scans of the local network for NetLink devices.
2. In the main window, review the list of NetLink devices detected. The view contains four columns: MAC
Address (hardware address), Serial Number (factory assigned), IP Address (configurable), Firmware
string containing device type, firmware revision, and firmware date. (configurable) (see Refresh List
for details).
3. Select Device | Set Temporary IP. Standard NetLink uses 0.0.0.0 for a default IP address. Before
parameter settings, including a permanent IP address, can be downloaded to the NetLink, a
temporary IP address must be assigned.
Note: There is a three-minute window for setting a temporary IP address after power on. If it is not
set in that time, NetLink responds with error code -1.
Tip: Use the same IP address that will be permanently saved later for the temporary IP address (see
Set Temporary IP Address).
5. Select Device | Parameter Settings to define how communications take place from the PC to the
NetLink and from the NetLink to the PLC.
6. In the Parameter Settings dialog, enter the permanent IP Address, subnet mask, and gateway (if
applicable; if not, leave the field empty). If the Profibus Parameters need to be altered, click
Advanced....
www. kepware.com
5 NetLink Configuration Utility
8. When the download process completes, a dialog appears prompting to disconnect and reconnect the
NetLink from the PLC. Click Yes when the NetLink is reconnected.
Refresh List
To scan for NetLink devices on the local network, select Device | Refresh List.
www. kepware.com
NetLink Configuration Utility 6
The main window displays a list of all NetLink devices detected. The view contains four columns:
If a known NetLink is not in the list, disconnect and reconnect this NetLink, wait about 10 seconds and then
perform another Refresh List.
To begin any Configuration or Firmware operation with the device, an IP Address must be assigned to that
device.
Note: There is a three-minute window for setting a temporary IP address after power on. If it is not
set, the NetLink responds with error code -1.
www. kepware.com
7 NetLink Configuration Utility
4. Enter a valid IP address and click Set. The temporary IP address is downloaded to RAM.
5. Once a temporary IP address is assigned, Firmware and Parameter Settings can be downloaded to
the NetLink.
Parameter Settings
Parameter Descriptions
Description of each parameter
Parameter Download
www. kepware.com
NetLink Configuration Utility 8
Parameter Descriptions
Important: With the exception of MAC address and IP address, the default parameter values do not
necessarily indicate current device settings. Settings are write-only and are not read from the device.
IP Address Settings
There are three ways the NetLink can be assigned IP parameters:
If more than one method is chosen, the NetLink tries each one, in the order listed above, until one succeeds.
Profibus Parameters
Bus Profile
The bus profile presets the parameter values to best match the given bus. For example, MPI defaults at
187.5K baud whereas Profibus defaults at 1.5M baud. Changing the bus profile affects the following
parameters:
l Baud Rate
l Slot Time
l Minimum Station Delay
l Maximum Station Delay
l Quiet Time
www. kepware.com
9 NetLink Configuration Utility
l Setup Time
l Target Rotation Time
l GAP Factor
l Max Retry
Baud Rate
Baud rates available are:
9600
19.2K
93.75K
187.5K
500K
1.5M
3M
6M
12M
Parameter Download
When the Download button is selected in the Parameter Settings dialog, a warning is displayed.
Click Yes to perform the download or No to cancel. Once the download is in process, a progress percentage
is displayed.
www. kepware.com
NetLink Configuration Utility 10
When the download process completes, a dialog appears prompting to disconnect and reconnect the
NetLink from the PLC.
It is necessary to reconnect the device for this new configuration to be used. Click Yes when the NetLink is
reconnected. The NetLink Configuration Utility pauses to allow the NetLink to complete its power-up
sequence.
If the No button is selected, a warning will be displayed. It is necessary to reconnect the device for this new
configuration to be used. Otherwise the previous configuration remains active.
www. kepware.com
11 NetLink Configuration Utility
Calculated Timing
Bit Time
The time it takes to transmit 1 bit.
Bit Time = 1/Baud Rate.
Configure Timing
Slot Time
Time Sender waits for acknowledgment / response before retrying.
Value Range: 37 ... 16383
Default: 415 (MPI), 300 (PROFIBUS)
www. kepware.com
NetLink Configuration Utility 12
Minimum time period that must elapse before the responder may send an acknowledgment/response.
Value Range: 1 ... 65535
Default: 60 (MPI), 11 (PROFIBUS)
Quiet Time
Time delay for modulators/repeaters to switch from sending to receiving.
Value Range: 0 ... 127
Default: 1 (MPI), 0 (PROFIBUS)
Setup Time
Time sender must wait between receiving an acknowledgment / response and sending next telegram.
Value Range: 1 ... 255
Default: 1 (MPI), 1 (PROFIBUS)
Firmware
To update NetLink firmware, select Device | Firmware.
www. kepware.com
13 NetLink Configuration Utility
Download Settings
Selected Firmware
The name of the firmware file to download. File is selected via the browse (...) button.
Firmware Version
Firmware revision of the selected firmware file to download. The firmware string follows the same syntax as
the current firmware version.
Click the button to locate available firmware files. The following dialog appears.
www. kepware.com
NetLink Configuration Utility 14
NetLink firmware files have a file extension of "E11." Once a file is selected, click the Open button to accept
the selection.
With a firmware file selected, a comparison can be drawn between the current firmware version and the
selected firmware version.
Click Yes to perform the download or No to cancel. During the download process, a progress percentage
displayed.
When the download process completes, a dialog appears prompting to disconnect and reconnect the
NetLink from the PLC.
www. kepware.com
15 NetLink Configuration Utility
It is necessary to reconnect the device for the new firmware to be used. Click Yes when the NetLink is
reconnected. The NetLink Configuration Utility pauses to allow the NetLink to complete its power-up
sequence.
If the No button is selected, a warning is displayed. It is necessary to reconnect the device for the new
firmware to be used. Otherwise, the previous firmware remains active.
www. kepware.com
NetLink Configuration Utility 16
Troubleshooting
If the IP address displayed in the list is NOT 0.0.0.0, verify that the IP address is valid for the local network.
An IP address may have been downloaded (i.e. "Parameter Download" on page 9) that does not meet the
local network's subnet mask.
See Also:
Set a Temporary IP Address
Set a Permanent IP Address
Download the Parameter Settings
Error Codes
The following table describes possible error codes presented by the NetLink Configuration Utility.
If a the device reports an error during configuration or firmware download, a value of 1000 is added to the
error number.
www. kepware.com
17 NetLink Configuration Utility
Index
Baud Rate 9
Calculated Timing 11
Contents 3
Error Codes 16
Firmware 12
Help Contents 3
IP Address 8
www. kepware.com
NetLink Configuration Utility 18
MAC Address 6
Navigation 3
Overview 3
Parameter Descriptions 8
Parameter Download 9
Quiet Time 12
Refresh List 5
Remote Station 16
Station Address 9
Station Delay 11
Target Rotation 11
Temporary IP Address 6
Troubleshooting 16
www. kepware.com