LP Series-General Purpose

LP12-38(12V38Ah)

Specifications
Rated Voltage 12V
38.0Ah (C10,1.80V/cell)

197±2mm (7.76 inches)


165±2mm (6.50 inches)
170±2mm (6.69 inches)
170±2mm (6.69 inches)

12.0 Kg (26.9 Ibs)


M6
ABS

40.0 Ah (20hr,2.00A,1.80V/cell)
38.0 Ah (10hr,3.80A,1.80V/cell)
(25 0 C ) 32.6 Ah (5hr,6.52A,1.75V/cell)
29.2 Ah (3hr,9.74A,1.75V/cell)
24.0 Ah (1hr,24.0A,1.60V/cell) Layout
380A (5s)
(25 0 C ) Approx 10mΩ
Discharge -15~500C (5~1220F)
Charge -20~400C (-4~1040F)

161±2
170±2
Storage -15~400C (5~1040F)

25±3 0 C (77±5 0 F )
Initial Charging Current less than 11. 4A. Voltage
Cycle Use 0 0 0
14.4V~15.0V at 25 C(77 F)Temp. Coefficient -30mV/ C

Standby Use Initial Charging Current less than 11. 4A. Voltage ∅16
13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0 C

6
40 0 C (104 0 F) 103%

165±2
Effect of temp. to Capacity 25 0 C ( 77 0 F) 100% M6

61.5±1
00 C ( 32 0 F) 86%

LP series batteries may be stored for up to 6 months


at 25 0 C(77 0 F) and then a freshening charge is required. 158±2
197±2
For higher temperatures the time interval will be shorter.

Constant Current Discharge (Amperes) at 25 0 C (77 0 F )


F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 87.0 61.8 57.7 45.6 34.6 25.1 18.9 14.7 11.8 8.66 7.08 5.92 5.47 4.17 3.49 1.83
1.80V/cell 98.9 70.2 64.5 51.0 38.7 26.6 20.9 16.1 12.8 9.50 7.63 6.37 5.87 4.47 3.80 2.00
1.75V/cell 107.4 76.1 68.9 54.4 41.3 27.5 21.6 16.6 13.2 9.74 7.82 6.52 5.92 4.55 3.84 2.02
1.70V/cell 114.9 81.2 72.4 57.2 43.5 28.1 22.4 17.2 13.7 9.92 8.02 6.66 5.95 4.63 3.88 2.04
1.67V/cell 118.9 83.7 73.6 58.1 44.1 28.5 22.9 17.5 13.8 10.1 8.13 6.74 5.98 4.68 3.91 2.05
1.60V/cell 123.1 86.6 74.6 59.0 44.8 28.9 24.0 18.3 14.4 10.4 8.36 6.95 6.02 4.79 3.96 2.08

Constant Power Discharge (Watts/cell) at 25 0 C (77 0 F )


F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 159.5 114.2 102.7 81.2 61.7 45.3 40.0 28.4 22.7 17.4 13.8 11.5 10.4 8.16 6.86 3.60
1.80V/cell 178.4 127.8 114.9 90.8 69.0 47.7 43.8 30.9 24.6 18.6 14.7 12.4 11.1 8.71 7.28 3.82

1.75V/cell 190.4 136.4 122.6 96.8 73.5 49.1 45.1 31.7 25.3 19.0 15.1 12.6 11.1 8.88 7.39 3.88
1.70V/cell 200.2 143.4 128.9 101.9 77.4 49.7 46.4 32.6 26.0 19.6 15.4 12.8 11.2 8.98 7.49 3.93

1.67V/cell 203.4 145.7 131.0 103.5 78.6 50.2 47.1 33.1 26.2 19.9 15.6 13.0 11.2 9.09 7.54 3.96
1.60V/cell 206.3 147.7 132.9 105.0 79.7 50.4 48.9 34.2 27.2 20.4 15.9 13.3 11.2 9.28 7.66 4.03
LP Series-General Purpose
LP12-38(12V38Ah)

Applications General Features Stand ards


• All purpose • 10 years design life(25℃) • Compliance with IEC 60896 standards,
• Uninterruptable Power Supply (UPS) • Special exhaust structure and sealing technology, EU Battery Directive
• Electric Power System (EPS) safe and reliable, flexible installation, convenient • UL, CE Certified
maintenance
• Emergency backup power supply
• Manufactured in Leoch®IATF16949,
• Alarm and security system • PbCaSn alloy for plate grids: less gassing, less
self-discharging ISO45001,ISO 9001 and ISO 14001
• Communication power supply certified production facilities
• High quality AGM separator: extend cycle life
• DC power supply and prevent micro short circuit
• Auto control system • High purity raw material: ensure low self discharge rate

Discharge Characteristics Float Charging Characteristics


12V
Battery
(V) Temperature:25 0 C(77 0 F) Charge Charging Charging
Volume Current Voltage
13 0
(V) 0.10CA-2.25V/cell temperature25 C
% (XCA)

12
0.25
120
Terminal Voltage(V)

15
110 Charged Volume
11
0.20
100
0.1C 0.05C 14
0.2C 90 Charge Voltage
10 0.4C 80 0.15 (Constant 2.25v/cell)
70 13
1C 0.6C
9 60
After 50% Discharge
50 0.10
12
40 After 100% Discharge
8 30
2C 0.05 11
20
10 Charging Current
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0 0
Min H
0 4 8 12 16 20 24 28 32 36 40
Discharge Time Charging Time(hours)

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

120 12
0.1CA
100 0.17CA 10
Capacity(%)

0.25CA
80 8
Float life(year)

60 6

40 4

20 2

0
-20 -10 0 10 20 30 40 50 60 (oC) 20 25 30 35 40 45
o
50 ( C )
o
-4 14 32 50 68 86 104 122 140 ( F) 68 77 86 95 104 113
o
122 ( F)
Battery temperature Battery Temperature

Sales Offices Worldwide


China Sales Office HongKong Sales Office Singapore Sales Office Australia Sales Office
5th Floor, Xinbaohui Bldg., Nanhai Blvd., Workshop C, 33/F, TML Tower, No. 3 Hoi Shing Road, No. 1 Tech Park Crescent, 2 /29 Tarlington Place, Smithfield. NSW 2164
Nanshan, Shenzhen, China. 518052 Tsuen Wan, New Territories, Hong Kong Singapore 638131 Australia
Tel: +86-755-86036060 (100 lines) Tel: +852 35786666 Tel: +65 68636078 Tel: 02 9756 0950
Fax: +86-755-26067269 Fax: +44 1452 690125 Fax: +65 6863 6079 E-mail: [email protected]
E-mail:[email protected] E-mail: [email protected] Email: [email protected]

North America Sales Office UK Sales Office EMEA Sales Office India Sales Office
19751 Descartes 9B Wheatstone Court. Waterwells, Business Park, 1 Deligiorgi St., 121 31 Athens, Shed no.A-53(b), 2nd Stage of Peenya Industrial Area,
Foothill Ranch, CA 92610, USA Gloucester, GL2-2AQ, UK United Kingdom Greece Bangalore North Taluk, Bangalore-560058, India
Tel: 949-588-5853 Tel: +44(0) 1452 729428 / 1452 729696 Tel: +30 210 5760318 (2 lines) Tel: +91-80-23440018/23440019
Fax: 949-588-5966 Fax:+44 1452 690125 E-mail: [email protected] Fax: +91-80-23440017
E-mail: [email protected] E-mail: [email protected] Http:// www.leoch.eu E-mail: [email protected]
Http:// www.leoch.us Http:// www.leoch.eu

© 2020 LEOCH. All rights reserved.


Http://www.leoch.com Trademarks and logos are the property of LEOCH and its affiliates unless otherwise noted.
Subject to revisions without prior notice. Publication No.: LB-LP12-38-PD-EN-V2.1-202110

You might also like