EN TECHNICAL SPECIFICATIONS DIMENSIONS MODBUS ADDRESS

A/D Converter* 24 x 24 x 4.5 mm R/W Adr Data Description


R/W 0 Command Command Register
www.etarti.com Minimum Input 0.13uV/Division [2mm Mounting Hole]
R/W 1 RegA Extension for command
Analog Input Range* 3.9mV/V 22.5mm R/W 2 RegB Extension for command
0:Free
Loadcell Input* 350-1000 Ohm (Maxs. 10 Loadcells)

LCT SMART TRANSMITTER


1:Tare (0:No tare, 1:Tared)
Internal Resolution* 24bits / 16.000.000 2:Stable (Display is stable)
3:AbsZero (Display is Absolute)
Status-A
Measurement Speed* 100 samples/second R/O 4-6: N/A

22.5mm
Devices 7: Digital Output State 0:Off, 1:On
& 3
Loadcell Excitation* 3.3Vdc R/W
information bits 8-10: 3bit Decimal Point
11: Language on use. 0:TR, 1:EN
Calibration 12:Digital Input state. 0:No input, 1:Active
13: x10 (0:Normal, 1:x10 Active)
Calibration Digital calibration via modbus 14:x10Dot(0:Normal, 1:Additional dot is on)
15:User In Menu (0:Normal, 1:User operation on menu)
24mm
*Only Loadcell optipon applied 0-2: N/A
3-6: Modul Unit
0:None, 1:g, 2:kg, 3:ton, 4:N, 5:kN, 6:lb, 7:liter,8:mV, 9:V, 10:°C, 11:°F
Status-B
Input/Outputs Devices
7:Digital Output state. 0:OFF, 1: ON
8:Forced Control. 0:OFF, 1: ON
RW 4
Options 1pcs 0/10V – 4/20mA Analog Output information bits 9:Forced Output state when force mode is On. 0:OFF, 1: ON

1pcs Analog Input (0-36V @10mV res) ELECTRICAL CONNECTIONS 10-12: N/A
13:Keypad Locked state. 0:Non-Locked, 1:Locked
14: G-Logic. 0:OFF, 1: ON
1pcs PT100-PT1000 interface +24V --> +Supply 15: G-Logic++. 0:OFF, 1: ON

Communication GND --> -Supply


0-7:Error Message (0-255 Screen Error Message)
8:Digital Output option. 0: None, 1:Device has Digital Output option
9: Analog output option 0:None, 1:Device has AnalogOutput option
Communication 1pcs RS485 serial output port. 1200- A+ --> *RS485 A Line Status-C 10: ADC in high speed 0:Normal, 1:High conversion rate active
115200bps Modbus RTU communication or B- --> *RS485 B Line RW 5 Devices 11:Security lock. 0: Normal, 1:Device in locked by licence issue
12: OLED display in error
information bits
Remote Display output 0/10V --> *0-10V Output 13:ADC module is in Err
14:ADC is in overflow state, Check Loadcell
4/20mA --> *4/20mA Output 15:Maximum Error
RW 6/7 Tare Tare Value
Environments *Optional hardware
RO 8/9 Display Weight Screen
Supply/ Power 24Vdc (+/- % 10) / 5W maximum RW 10 DAC From Analog output start value in mV.
(Opsiyonel 6V-9V-12V supply possibilies) SENSOR SIDE RW 11 DAC To Analog output End value in mV. (10V=10000)
Case/ Dimensions None - 24x24x4.5mm Shield --> If shield exists RW 12 DAC Current Current value of the analog output
I- --> Sensor - RO 13 DAC Status 0:Normal output, 1: DAC Forced output from DAC Current
M2 mounting hole RO 14-15 Capacity Capacity of the device (for Err-1 on Display)
Working Temperature -20/70°C I+ --> Sensor + RO 16-17 ADC Internal Internal real time measurement result
Protection Class IP65 E- --> Sensor Exc- RW 18-19 ADC Filtered Filtered value. See gLOGIC and Sensor parameters
E+ --> Sensor Exc+ RW 20-21 mV/V mV/V value corresponding to load
RW 22-23 mV Cal Capacity Used for eCAL mV/V calibration calculation
RW 24 Counter Counts up 100ms. Used to test communication and base address check
RW 25 Filter Size Filter Size in use 1-128
RW 43 Voltage Input Voltage measurement on INP terminal 0.0-24.0Volt

LCT Loadcell transmiters are smart devices which are designed to OPTIONS SETTING THE OUTPUTS
adapt to the industrial environment in many weight and force ANALOG INPUT: 0/10V or 0-4/20mA Analog output Modbus Commands
Address 0-1-2 are used to to special commands to device!!
measurement systems, thanks to their tiny dimensions. It can be ANALOG INPUT: P100 / PT1000 Interface Z --> Decrease / ZERO Adr0 Adr1 Adr2 Description
easily mounted on native wheatstone bridge type strain sensors. ANALOG OUTPUT: 0/10V – 4/20mA Analog output COM --> GND 2 Adres Data Eeprom write, Reg1 Address, Reg2 Data. Cmd address 2.
With its 24x24mm dimensions, it can be easily adapted to almost C --> Increase / CAL 3 Adres Data Eeprom read. Reg1 Address and the result is seen on RegB.
4 - - Device reset command
anywhere. It can transfer data to existing systems with RS485 An Inp --> *Analog Input (0/24V) 5 - - Zero operation. (Volatile, when power down the zero is cleared)
standard Modbus RTU communication. In addition, 0-10V – 4/20mA *Optional analog input 6 - - Tare operation. *when weight is differ from zero
output can be obtained without a hardware requirement, it can 7 - - Tare cancel opration. Tare cleared
easily set the outputs with side inputs. Setting Output for Unloaded Stage (Zero) Device type read. Reg1 is shows device ID code, LQi family is
8 - -
47621.
Make short circuit [Z/COM] terminals more than 2seconds (while in 9 - - Device version read on Reg1. 107 = v1.0.7
ACTIONS AND SIDE INPUTS this stage LED will blink in high speed). Device will enter the Zero 10 - - Parameters are updated from eeprom to RAM
setting stage (required output value when unloaded), led blinks Record Settings
11 - - Filter Size, ADC Speed, GLogic, mV Capacity, Capacity, DAC fro-to,
twice. By Z/COM terminals the output value will be decreased and Output Set,delay,reverse states
SIDE INPUT ACTION C/COM terminals the output value will be increased. Wait more Calib. Calib.
Calibration operation. Reg1 and Reg2 values are used used to
108 hold calibration value. To calibrate 100,000;
than 5seconds to save setup automatically, led will blink 3times to Low High
0-Command:108 1-Reg1: 34464 (low) 2-Reg2: 1 (high)
notify that operation has ended. 122 - - Calibration Zero is done. No need to do other actions
Z Zero Setting Output for Loaded Stage (CAL) 112 - - Keypad lock enable command
Make short circuit [C/COM] terminals more than 2seconds (while in 113 - - Keypad lock disable command
Coefficient calibration. Reg1 and Reg2 is used to ented coefficient
C Maximum this stage LED will blink in high speed). Device will enter the Load 107
Coeff. Coeff.
value. To set the Coefficient= 1.000000;
Low High
setting stage (required output value when loaded), led blinks twice. 0-Command: 107 1-Reg1: 16960 (Low) 2-Reg2: 15 (High)
System Capacity is set to address 22-23. As a mV/V value, the
By Z/COM terminals the value will be decreased and C/COM
Z/C Factory Reset terminals the vale will be increased. Wait more than 5seconds to
total systems loadcells capacity, is set to Reg1 and Reg2 (2 000
000). As an example; 4pcst 10ton capacity with 2.000000mV/V
mV mV
save setup automatically, led will blink 3times to notify that 109
Low High
output loadcelss, 40000 values is entered 22-23 registers.
0-Command: 109
Z (Zero) input used to set analog output (From value) when operation has ended. 1-Reg1: 33920 (Low)
the load is ZERO (Unloaded). 2-Reg2: 30 (High).
Factory Settings 123 ZeroL ZeroH Shift Zero (Declerated) Zero is equal to Adr1 and Adr2x65536

While in power up the device, make short circuit [C/COM] terminals


C (Calib) input used to set analog output (To value) when the Calibration video can be found or [Z/COM] more than 10seconds. Led will blinks speedy to while
sensor loaded state. the operation is in progress
on this link below;
www.youtube/e-tarti
Short circuit the terminal and hold more than 2seconds to achieve
POWER REQUIREMENTS
mode.
Supply voltage is 24Vdc, maximum 5W power required

rev 240601 v1.0.1


TR TEKNIK ÖZELLIKLER BOYUTLAR MODBUS ADRESLERI
A/D ÇEVİRİCİ 24 x 24 x 4.5 mm Y/O Adr Veri Tanım
www.etarti.com Minimum Giriş 0.13uV/Bölüntü [2mm Montaj Deliği] RW 0 Komut Komut Register
22.5mm RW 1 RegA Komut yardımcı adres
Analog Giriş Aralığı 3.9mV/V RW 2 RegB Komut yardımcı adres

LCT AKILLI ÇEVIRICI


0:Kullanım dışı
Yük Hücresi Giriş 350-1000 Ohm (Maks. 10 Yük Hücresi) 1:Dara 0:Dara Yok, 1:Dara Aktif
2:Stabil (Ekran kararlı)
İç Çözünürlük 24bit / 16.000.000 3:Mutlak Sıfır (Ekran mutlak sıfır)
Status-A

22.5mm
Ölçüm Hızı 100 örnek/saniye Cihaz Bilgi
4-6: N/A
7: Dijital Çıkış durumu 0:Kapalı, 1:Açık
RW 3
Yük Hücresi Besleme 3.3Vdc Bayrakları 8-10: 3bit Nokta yeri
11: Dil seçimi. 0:TR, 1:EN
KALİBRASYON 12:Dijital Giriş durum. 0:Giriş Yok, 1:Aktif
13:x10 (0:Normal, 1:x10 Active)
Kalibrasyon Yük ile kalibrasyon veya Dijital kalibrasyon 24mm
14:x10Dot(0:Normal, 1:Additional dot is on)
15:Kullanıcı menude (0:Normal, 1:User operation on menu)
*Sadece Loadcell opsiyonlu cihazlarda geçerlidir 0-2: N/A
3-6: Birim
0:None, 1:g, 2:kg, 3:ton, 4:N, 5:kN, 6:lb, 7:l, 8:mV, 9:V, 10:°C, 11:°F
Status-B 7:Digital Output state. 0:OFF, 1: ON
GİRİŞ/ÇIKIŞLAR RW 4
Cihaz Bilgi 8:Forced Control. 0:OFF, 1: ON

Opsiyonlar 4/20mA - 0/10V Analog Çıkış ELEKTRİKSEL BAĞLANTILAR Bayrakları 9:Forced Output state when force mode is On. 0:OFF, 1: ON
10-12: N/A
13:Keypad Locked state. 0:Non-Locked, 1:Locked
PT100-PT1000 Okuma Girişi 14: G-Logic. 0:OFF, 1: ON
0-10V Analog Okuma Girişi +24V --> +Besleme 15: G-Logic++. 0:OFF, 1: ON
GND --> -Besleme 0-7:Error Message (0-255 Screen Error Message)
HABERLEŞME 8:Digital Output option. 0: None, 1:Device has Digital Output option
A+ --> *RS485 A Status-C 9: Analog output option 0:None, 1:Device has AnalogOutput option
Haberleşme 1 adet RS232, 1adet RS485 seri çıkış. B- --> *RS485 B Cihaz Bilgi 10: ADC in high speed 0:Normal, 1:High conversion rate active
RW 5 11:Security lock. 0: Normal, 1:Device in locked by licence issue
[1200-115200bps] 0/10V --> *0-10V Çıkış
Bayrakları 12: OLED display in error
13: ADC module arızalı (err90)
Modbus RTU haberleşme 4/20mA --> *4/20mA Çıkış 14: ADC Aşırı yüksek. Yük hücresini kontrol ediniz
15: Kapasite Aşımı hatası
*Opsiyonel donanım RW 6/7 Dara Tare Value
ORTAM KOŞULLARI RO 8/9 Ekran Weight Screen
RW 10 DAC Başla Analog output start value in mV.
Besleme/ Güç 24Vdc (+/- % 10) / 5W maximum SENSOR GİRİŞİ RW 11 DAC Bitiş Analog output End value in mV. (10V=10000)
(Opsiyonel 6V-9V-12V besleme seçenekleri) Shield --> Eğer ekranlı kablo ise RW 12 DAC Anlık Current value of the analog output
Kutu/ Ebatlar Panel Tipi Plastik Kutu, 50x50x30mm I- --> Sensor - RO 13 DAC Durum 0:Normal output, 1: DAC Forced output from DAC Current
RO 14-15 Kapasite Capacity of the device (for Err-1 on Display)
(45mm Delik Çapı) I+ --> Sensor + RO 16-17 ADC İÇSayım Internal real time measurement result
Çalışma Sıcaklığı -20/70°C E- --> Sensor Exc- RW 18-19 ADC Filtreli Filtered value. See gLOGIC and Sensor parameters
Koruma Sınıfı IP65 E+ --> Sensor Exc+ RW 20-21 mV/V mV/V value corresponding to load
RW 22-23 mV Kal Kapasite Used for eCAL mV/V calibration calculation
RW 24 Sayaç Counts up 100ms. Used to test communication and base address check
RW 25 Filtre Boyu Kullanımdaki filtre boyu 1-128
RW 43 Voltage Giriş INP terminaldeki giriş gerilimi seviyesi 0.0-24.0Volt
LCT akıllı çevirici cihazları minik ebatları sayesinde bir çok ağırlık OPSIYONLAR AYARLAMA VE YAN GİRİŞLER
ve kuvvet ölçümü sistemlerinde endüstriyel ortama uyum sağlamak Modbus Özel Komutları
ANALOG GİRİŞ: 0/10V veya 0-4/20mA Analog okuma
amacıyla tasarlanmışlardır. 24x24x4.5mm ebatları ile hemen her 0-1-2 nolu adresler kullanılarak özel komutlar icra edilir!
yere kolaylıkla adapte edilebilirdir. RS485 standart modbus RTU ANALOG GİRİŞ: PT100 / PT1000 Girişi Adr0 Adr1 Adr2 Açıklama
ANALOG ÇIKIŞ: 0/10V – 4/20mA Analog Çıkış Z --> Azaltma / ZERO
haberleşmesi ile var olan sistemlere veri aktarabilir. Ayrıca bir 2 Adres Data Eeproma yazma, Reg1Adres, Reg2 Data konur. Cmd 2 kaydeder.
COM --> GND 3 Adres Data Eepromdan okuma. Reg1 Adres , sonuç RegB de güncellenir.
donanım gereksinimi olmadan 0/10V- 4/20mA çıkış alınabilir,
C --> Artırma / CAL 4 - - Cihaz resetleme komutudur
kenar ayar girişleri ile kolaylıkla set edilebilir. 5 - - Sıfırlama işlemidir. (Enerji gidip geldiğinde iptal olur)
An Inp --> *Analog Input (0/24V)
6 - - Dara alma işlemidir. Ağırlık Sıfırdan farklı ise dara alınır
*Opsiyonel analog giriş 7 - - Dara iptal etme işlemidir
AKSİYON VE GİRİŞLER Cihaz tipi okuma komutudur. Reg1 da cihaz tipi okunur. LDr
8 - -
Yüksüz Durum için Çıkış Ayarlama (Sıfır) ailesi için 47604 okunur.
9 - - Cihaz versiyon Reg1 içerisine okunur. 107 = v1.0.7
KENAR GIRIŞ AKSIYON [Z/COM] terminalleri 2sn den daha fazla kısadevre edilir (bu anda 10 - - Parametreler eepromdan okunarak RAM a guncellenir
LED hızlı olarak yanıp sönecektir). Sıfır ayarlama moduna Parametreler kaydedilir
geçildiğinde (Yüksüz durumda verilecek çıkış), led iki kez yanıp 11 Filtre boyu, ADC hızı, GLogic, noktayeri, mV Kapasite, Kapasite,
Z Zero DAC başla-bitiş, Çıkış set,gecikme,kontak
sönmeye başlar. Z/COM terminalleri ile çıkış değeri azaltılır ve Kalibrasyon işlemidir. Reg1 ve Reg2 değerlerine kalibre edilecek
Kalib. Kalib.
C/COM terminalleri ile çıkış değeri artırılır. 5sn den daha fazla 108
Düşük Yüksek
değer girilir. 100,000'e kalibre etmek için;
C Maximum beklenir ise otomatik olarak mevcut durum kaydedilir ve led 3kez 0-Komut:108 1-Reg1: 34464 (low)2-Reg2: 1 (high) yazılır.
122 - - Kalibrasyon sıfırı alınır. Başka bir işleme gerek yoktur
yanıp söner. 112 - - Tuş kilidi aktif edilir
Z/C Factory Reset Yüklü Durum için Çıkış Ayarlama (Kalibre) 113 - - Tuş kilii kaldırılır
[C/COM] terminalleri 2sn den daha fazla kısadevre edilir (bu anda 123
Sıfır Sıfır
Shift Zero (Declerated) Zero is equal to Adr1 and Adr2x65536
Düşük Yüksek
LED hızlı olarak yanıp sönecektir). Yüklü durum ayarlama moduna
Z girişi yüksüz konumda alınmak istenen analog çıkış geçildiğinde LED iki kez yanıp dönmeye başlar (Yükü durumda çıkış 107
Coeff. Coeff.
Katsayı kalibrasyonu işlemidir. Reg1 ve Reg2 değerlerine kalibre
edilecek değer girilir. Katsayı = 1.000000 yapmak için;
Düşük Yüksek
değerini ayarlamak, ve ayar esnasında çıkışı azaltmak için ayarlama modu). Z/COM terminaleri ile çıkış değeri azaltılır ve 0-Komut: 107 1-Reg1: 16960 (Low) 2-Reg2: 15 (High) yazılır.
Sistem Kapasitesi 22-23 nolu adreslere yazılır. mV/V olarak
kullanılır. C/COM terminalleri ile çıkış değeri artırılır. 5sn den daha fazla sistemdeki yük hücrelerinin ortalama değeri Reg1 ve Reg2 ye
Kalibrasyon video anlatımı için beklenir ise otomatik olarak mevcut durum kaydedilir ve led 3kez yazılır(2 000 000). Örnek olarak 4 adet 10ton kapasiteli
mV mV 2.000000mV/V çıkışlıyük hücreleri için, once 22-23 adreslerine
C girişi yüklü durumdayken alınmak istenen analog çıkış değerini aşağıda linki kullanabilirsiniz. yanıp söner. 109
Düşük Yüksek 40000 yazılır.
belirlemek ve ayarlama esnasında çıkışı artırmak için kullanılır. www.youtube/e-tarti 0-Komut: 109
Fabrika Ayarlarına Geçiş 1-Reg1: 33920 (Low)
2-Reg2: 30 (High) olarak yazılır.
2sn veya daha uzun süre terminaller kısadevre edilerek ilgili ayara İlk enerjilenme durumnda, [C/COM] terminalleri ya da [Z/COM]
geçiş yapılır terminalleri 10sn den daha uzun sure ile kısadevre olarak tutulur.
İşlem boyunca Led hızlı olarak yönüp sönecektir.

GÜÇ TÜKETIM DEĞERLERI


Besleme gerilimi 24Vdc, maksimum 5W güç ihtiyacı vardır.

rev 2400601 v1.0.1