1MRK504112-Transformer Protection RET670 1.2 650 1.1
1MRK504112-Transformer Protection RET670 1.2 650 1.1
1MRK504112-Transformer Protection RET670 1.2 650 1.1
The RET670/650 IEDs (Intelligent Electronic Device) These IEDs provide you with a future-proof concept based on
provide fast and selective protection, monitoring and application flexibility, which makes them an excellent choice
control for all types of transformers, such as two and for both new and retrofit installations. The integration of the
three-winding transformers, step-up transformers in main protection and a wide range of back-up protection func-
power stations and special railway transformers. In tions within these IEDs improve your power system perform-
addition, RET670 offers state-of-the-art protection for ance. It also reduces engineering and installation time as well
autotransformers, phase shifting transformers and shunt as space and spare parts requirements.
reactors including switching control. With up to six three
phase restraint current inputs into differential protection, RET670 – maximum flexibility and performance
it allows for multi-breaker substation arrangements on The RET670 IEDs provide customized or pre-configured pro-
any transformer side. The advanced RET670 and RET650 tection solutions for any type of transformer and shunt reactor
communication capabilities allow you to integrate these application. The customized RET670 gives you the freedom
IEDs into your substation automation system or use them to select functionality entirely according to your needs. The
as stand-alone multifunctional units. pre-configured RET670 variants simplify handling since the
basic functionality is included and pre-configured. If needed,
The transformer protection IEDs offer several solutions for you can add optional functions to increase the functionality of
voltage control. Voltage control can be integrated in the same the pre-configured RET670 IEDs to meet the specific require-
IED together with differential protection function and back-up ments of your transformer or shunt reactor.
protection functions, or as a separate stand-alone voltage
control unit. The advanced voltage control functionality of You can also protect and control several objects with a single
RET670 is capable of handling single and up to eight parallel RET670 IED. For instance, a single RET670 IED can integrate
transformers in any combination of parallel groups. RET650 is complete protection and control functionality for a transformer
capable of handling single and up to four parallel transformers. and a connected transmission line. The distance protection
function can also be used as back-up protection for faults
2
within the transformer. This solution provides efficient protec- Non-directional and/or directional overcurrent functions
tion and control in FACTS installations. The distance protec- provide the necessary back-up protection. This, together with
tion function can also be used as back-up protection for faults fast and sensitive restricted earth-fault protection of stabilized
in the connected lines. The parameters related to line distance low impedance types, with sensitivity down to 1% of the total
protection are mostly set as primary ohms, which significantly number of turns, ensures comprehensive protection for your
reduce the need to re-calculate the current and voltage values. power transformers. The thermal overload function prevents
This allows the IEDs to be quickly taken into operation. The transformer damage caused by overload. Breaker failure
application manual includes setting examples to support the protection allows high speed back-up tripping of surrounding
protection engineer. In all, RET 670 increases both the reliability breakers and re-tripping of the own breaker, for instance, to
and profitability of your entire power system. avoid operational mistakes during testing.
3
Intelligent protection investment
RET650 provides integrated voltage control for single/parallel Optimized utilization of transformers
transformers. The dedicated voltage control variant of RET650 is The monitoring functionality of the RET670 and RET650 IEDs
capable of handling two parallel operating transformers including provides important information about the state of the transform-
back-up protection. ers to an operator. The RET670 IEDs receive information about
the transformer temperature and issue an alarm, log the event
The right information for the right action and trip if needed. This gives the operator time to disconnect the
The integrated HMI of RET670 and RET650 provide you with transformer in case of an overload during network emergency
a quick overview of the status of the substation with position conditions. Early actions prevent forced ageing and prolong the
indications and service values. Using a library of symbols, you transformer lifetime. The information about temperature can also
can easily configure the graphical display to correspond to your be used to control the cooling system of the transformer.
needs and to your substation. The built-in disturbance and event
recorders provide you with valuable data for postfault analysis and Fast and efficient system integration
corrective actions to increase the security of your power system. The RET670 and RET650 IEDs are designed for IEC 61850,
implementing all aspects of this standard, thus ensuring open,
RET670 also features also functions for local and remote ap- future-proof and flexible system architectures, with state-of-the
paratus control on all sides of the transformer. Secure bay- and art performance. They utilize ABB’s unique connectivity package
station-wide interlocking allows you to avoid dangerous or dam- concept, which simplifies the system engineering and reduces
aging switchgear operations and to ensure personnel safety. The the risks of errors in system integration. A connectivity package
large HMI allows for local control and instant access of important contains a complete description of the specific IED, consisting of
4
data signals, parameters, addresses and IED documentation. Application examples
The signal data is configured automatically based on the informa-
tion provided by the connectivity package to efficiently integrate
the IEDs into ABB’s MicroSCADA Pro automation system.
670 series IEDs allow you to mix conventional wiring and fiber-
optic communication with IEC 61850-9-2 LE in a single IED. This
way you can shift from conventional wiring for analog data to fiber-
optic-based communication for synchronized sampled measured
values step by step.
5
RET670 Technology summary:
6
RET650 Technology summary:
Features Logic
• Fully IEC 61850 compliant • Tripping logic
• Protection and monitoring integrated in one IED • Trip matrix logic
• Extensive self-supervision including analog channels • Configurable logic blocks
• Four independent parameter setting groups
Monitoring
• Large HMI for visualization of single line diagrams and on-line
• Disturbance recorder
measurements
- 100 disturbances
• Integrated or detachable HMI with 1-5 m cable for flexible panel
- 40 analog channels (30 physical and 10 derived)
mounting
- 96 binary channels
• Ethernet interface for fast and easy communication with PC
• Event list for 1000 events
• Accurate time-synchronization via SNTP, DNP 3.0, IEC 60870-5-103
• Disturbance report
and IRIG-B serial interface
• Event and trip value recorders
• Signal matrix for easy configuration of binary and analog signals
• Fault locator
• User management and authority handling
• Event counters
Configured solutions • Supervision of AC input quantities
• Two winding transformer in single breaker arrangements • Insulation gas monitoring function
• Three winding transformer in single breaker arrangements • Insulation liquid monitoring function
• Voltage control for two parallel transformers • Circuit breaker condition monitoring
• Station battery supervision
Most important protection functions
• Indication of up to 135 binary signals via 15 three-color-state
• Transformer differential protection
indication LEDs on up to three pages
- Percentage bias restraint
- Waveform and second harmonic restraint for transformer inrush Measurements
- Fifth harmonic restraint for overexcitation • U, I, P, Q, S, f, and cosϕ
- Automatic CT ratio matching and vector group compensation • Differential voltage per zone
- High sensitivity for interturn faults • AC input quantities with accuracy better than 0.5%
• Low Impedance Restricted earth fault protection
Metering
- Extremely fast operation
• Energy metering function for energy statistics
• Current
• Pulse counting support for energy metering
- Instantaneous phase- and residual overcurrent protection
- Four step phase- and residual directional/non-directional Communication
overcurrent protection with definite and inverse time characteristics • IEC 61850-8-1 including GOOSE messaging
- Sensitive directional earth-fault protection • DNP 3.0 slave protocol
- Negative sequence directional overcurrent protection • IEC 60870-5-103 serial communication
- Broken conductor check
Setting, configuration and disturbance handling
- Thermal overload protection
• Protection and control IED manager PCM600
- Breaker failure protection
- Pole discordance protection Hardware
• Power functions • 1/2 x 19”, 6U height case
- Directional under- and over power protection • 10-20 analog inputs depending on the configured solution
• Voltage • Universal 1A/5A CT inputs
- Two step phase- and residual overvoltage protection with definite • Communication and processor module with 14 inputs
and inverse time characteristics • Binary input/output module with 9 inputs and 9 outputs
- Two step undervoltage protection with definite and inverse time • Possibility to add two optional binary input/output modules
characteristics (variants for two winding transformer in single breaker
- Overexcitation protection arrangements and voltage control for two parallel transformers)
- Loss of voltage check • Power supply modules from 48 to 250 V DC or 100 to 240 V AC
• Secondary system supervision with 9 outputs, 3 of which with trip circuit supervision
- Fuse failure supervision
- Breaker close/trip circuit monitoring Technical details are available in the RET650 Product Guide.
• Frequency functions
- Under- and overfrequency protection
- Rate-of-change frequency protection
Control functions
• Automatic voltage control for a single transformer
• Automatic voltage control for two parallel transformers based on the
minimum circulating current principle or master-follower principle
• Versatile switch with two positions
• Selector switch with up to 32 positions
7
Contact us
ABB AB
1MRK 504 112-SEN © Copyright 2010 ABB. All rights reserved. Imageneering 12/2010
Substation Automation Products
SE-721 59 Västerås, Sweden
Tel. +46 21 32 50 00
Fax +46 21 14 69 18
www.abb.com/substationautomation