You are on page 1/ 3

PIRANHA S D 50 HZ

Test Standard
H / m S2 Head — D166 ∆p / kPa ISO 9906, HI 11.6/14.6≤10kW
1/ — _D163
40 2D
S26/ 50 — D163
2DH5 360
36 S21 Z0HZ — D137 HH Curve Name
/2D
50HZ
S
32 17/2D — D143 320 D166
50H
28
Z 280 Impeller Diameter
166 mm
24 S12/2 23.6% Ef f . 30.5% 240
D5 28%
0HZ 23.4%
20 200

16 160
15.3 25.5% 149.8
12 120
A1
8 80

4 40

0 ▕◄ Application range ►▏ 0
P₂ /2.483
kW Shaf t power P2

1.6

1.2

0.8

η/ % Hy draulic ef f iciency

25.28
25
20
15
10
5
0
0 0.5 1 1.5 2 2.5 3 3.5 44.182 4.5 Q / l/s
2024-10-14

Operating data specification Power input 3.25 kW


Flow 4.182 l/s Head 15.3 m
Efficiency 25.3 % Shaft power 2.48 kW
NPSH Fluid Water
Temperature 20 °C Nature of system Single head pump
No. of pumps 1
Pump data
Type PIRANHA S D 50 HZ Make SULZER
Series PIRANHA & PIRANHA PE Impeller Macerator
N° of vanes 4 Impeller size 166 mm
Free passage Suction flange
Discharge flange G1¼" Type of installation
Moment of inertia Wet-well stationary
Motor data
Rated voltage 400 V Frequency 50 Hz
Rated power P2 2.6 kW Nominal Speed 2790 1/min
Number of poles 2 Efficiency 75.7 %
Power factor 0.879 Rated current 5.64 A
Starting current 35.5 A Rated torque 8.9 Nm
Starting torque 31.4 Nm Degree of protection IP 68
Insulation class F No. starts per hour 15

Sulzer reserv es the right to change any data and dimensions without prior notice Spaix® 6-24.2 - 2024/09/27 (Build 734), 64 bit
and can not be held responsible f or the use of inf ormation contained in this sof tware. Data v ersion July 24.1
Curve number
Pump performance curves
Reference curve
PIRANHA S 2P D 50 HZ PIRANHA S D 50 HZ
Discharge Frequency
G1¼" 50 Hz
Density Viscosity Test Standard Rated speed Date

998.2 kg/m³ 1 mm²/s ISO 9906, HI 11.6/14.6≤10kW 2805 1/min 2024-10-14


Flow Head Shaft pow er Pow er input Rated pow er P2 Hyd. efficiency NPSH

4.182 l/s 15.3 m 2.48 kW 3.25 kW 2.6 kW 25.3 %

H/ m Head — D166 ∆p / kPa


S2 — _D163
1/ 400
40 2D — D163
50
S26/2 HZ
— D137 HH
D 50 — D143 360
36 S HZ
21/2
D5
0HZ
320
32 S17/2
D5
0H
Z
280
28

24 S12 240
23.6% Ef f . 30.5%
/2D
50H 28%
Z
23.4%
20 200

16 160
15.3 149.8
25.5%

12 A1 120

8 80

4 40

0 ▕◄ Application range ►▏ 0
P₂ / kW Shaf t power P2
2.483
2.4

1.6

1.2

0.8

η/ % Hy draulic ef f iciency

28
25.28
24

20

16

12

0
0 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4 4.182 4.4 4.8 Q / l/s

Wet-w ell stationary


Impeller size N° of vanes Impeller Solid size Revision
166 mm 4 Macerator
Sulzer reserv es the right to change any data and dimensions without prior notice Spaix® 6-24.2 - 2024/09/27 (Build 734), 64 bit
and can not be held responsible f or the use of inf ormation contained in this sof tware. Data v ersion July 24.1
Frequency
50 Hz Motor performance curve
S26/2D 50HZ

Rated power Nominal Speed Number of poles Rated voltage Date


2.6 kW 2790 1/min 2 400 V 2024-10-14

0 10 20 30 40 50 60 70 80 90 100 110 120 130 P2/P2n / %

n / 1/min M/Mn s cos φ 95.48 % — cos φ I/In P₁ / kW η / %


4000 — n
1.3 0.92 1.3 — I/In 1.3 4.8
92
3800 — s
1.25 1.25 1.25 4.6
0.88 — P₁ 88
3600 1.2 1.2 1.2 4.4
0.84 — M/Mn 84
1.15 1.15 — η 1.15 4.2
3400
0.8 80
1.1 1.1 1.1
4
3200 0.76 76.35
76
1.05 1.05 1.05
3.8
3000 1 0.72 1 1 72
3.6
0.95
0.95 0.68 0.95 0.953
0.95 68
2805
2800 3.4
0.9 0.64 0.9 0.9 64
0.873 3.252
2600 3.2
0.85 0.6 0.85 0.85 60
3
2400 0.8 0.8 0.8
0.56 56
0.75 0.75 0.75 2.8
2200 0.52 52
0.7 0.7 0.7 2.6
2000 0.48 48
0.65 0.65 0.65 2.4
0.44 44
1800 0.6 0.6 0.6 2.2
0.55 0.4 0.55 0.55 40
1600 2
0.5 0.36 0.5 0.5 36
1.8
1400
0.45 0.32 0.45 0.45 32
1.6
1200 0.4 0.28 0.4 0.4 28
1.4
0.35 0.35 0.35
1000 0.24 1.2 24
0.3 0.3 0.3
0.2 1 20
800
0.25 0.25 0.25
0.16 0.8 16
600 0.2 0.2 0.2
0.12 0.6 12
0.15 0.15 0.15
400
0.1 0.08 0.1 0.1 0.4 8
0.065
200 0.04 0.2 4
0.05 0.05 0.05
0 0 0 0 0 0 0
0 0.4 0.8 1.2 1.6 2 2.483
2.4 2.8 3.2 3.6 P₂ / kW

Symbol No load 25 % 50 % 75 % 100 % 125 %


P₂ / kW 0 0.65 1.3 1.95 2.6 3.25
P₁ / kW 0.3256 0.9118 1.61 2.461 3.434 4.489
I/ A 2.35 2.679 3.331 4.319 5.641 7.28
cos φ 0.2 0.4912 0.6976 0.8224 0.8788 0.89
n / 1/min 2989 2964 2923 2865 2790 2699
s/% 0.3667 1.2 2.567 4.5 7 10.03
M / Nm 0 2.094 4.247 6.5 8.899 11.5
η/ % 0 71.28 80.74 79.24 75.71 72.4

Tolerance according to VDE 0530 T1 12.84 for rated power


Starting current Starting torque Moment of inertia No. starts per hour
35.5 A 31.4 Nm 15
Sulzer reserv es the right to change any data and dimensions without prior notice Spaix® 6-24.2 - 2024/09/27 (Build 734), 64 bit
and can not be held responsible f or the use of inf ormation contained in this sof tware. Data v ersion