AS-Interface sensor/actuator module

VAA-4E4A-KE-ZEJQ/E2L
< Housing with removable, mechanical and color coded terminals
< Communication monitoring
< Inputs for 2- and 3-wire sensors
< Addressing jack
< Power supply of outputs from the external auxiliary voltage
< Selectable supply to the sensors: External or from the module
< Function display for bus, external auxiliary voltage, internal
sensor supply, inputs, and outputs
< Red LED per channel, lights up in the event of output overload
< Switchable lead breakage detection (outputs)

KE switch cabinet module, 4 inputs and 4 outputs

Function
The AS-Interface I/O module VAA-4E4A-KE-ZEJQ/E2L is a control cabinet module with 4 inputs and 4 electronic outputs. The housing is only 22.5
mm wide and takes up little space in the control cabinet. The module is mounted by snapping onto the 35-mm DIN rail in compliance with EN
50022.
The connection is made via plug-in terminals. Four-terminal blocks (black) are used for the inputs and outputs. The connection of the external bulk
power and the AS Interface is via 2-terminal blocks (bulk power grey, AS-Interface yellow). Terminals for the inputs and outputs are mechanically
coded to prevent incorrect connection.
The supply to the inputs and the connected sensors can be fed either from the internal supply of the module (from the AS-Interface) or via an
external voltage source. A switch located on the side of the module changes the supply source. The choice of internal input supply is displayed via
the INT LED. The IN and OUT LEDs display the current switching status of the relevant inputs and outputs. The OUT LED also indicates an
overload or a lead breakage at the associated output.
Note:
The device is equipped with a communication monitor, which deactivates the outputs if the AS-Interface does not communicate with the module
for more than 40 ms. The communication monitor can be deactivated via the parameter P0. Filters that suppress pulses with a duration of 2 ms or
less at the inputs can be connected via the parameter P1.
Parameter P2 activates a lead breakage detection system for the outputs. This function detects and reports a missing load, providing the relevant
output is deactivated. The associated OUT LED and the 'peripheral fault' function display the signal transmitted to the AS-Interface master. A
signal indicating an overload of the internal input supply or the outputs is also transmitted to the AS-Interface master via the 'peripheral fault'
function. Communication via the AS-Interface continues even if a peripheral fault is set.

Dimensions

22.5 7 99
Release date: 2023-03-28 Date of issue: 2023-03-28 Filename: 209759_eng.pdf

102

Technical Data
General specifications
Node type Standard node
AS-Interface specification V3.0
Required gateway specification ≥ V2.0

Refer to "General Notes Relating to Pepperl+Fuchs Product Information".


Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 1111 Singapore: +65 6779 9091
www.pepperl-fuchs.com [email protected] [email protected] [email protected] 1
AS-Interface sensor/actuator module VAA-4E4A-KE-ZEJQ/E2L
Technical Data
Profile S-7.0
IO code 7
ID code 0
ID1 code F
ID2 code E
UL File Number E223772
Indicators/operating means
LED FAULT Error display; red LED
red: communication error, i.e. address is 0
red flashing: overload internal input supply, i.e. overload or lead interruption outputs
LED INT Internal input supply active; LED green
LED PWR AS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
LED AUX ext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
LED IN switching state (input); 4 LED yellow
LED OUT switching state (output); 4 LED yellow/red
yellow: output active
red: output overload or lead interruption
Electrical specifications
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
Rated operating voltage Ue 26.5 ... 31.6 V from AS-Interface
Rated operating current Ie ≤ 35 mA (without sensors) / max. 190 mA
Protection class III
Surge protection UEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV)
Input
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
Supply from AS-Interface (switch position INT, default settings) or external UEXT (switch
position EXT)
Voltage 21 ... 31 V DC (INT)
Current loading capacity ≤ 150 mA, overload- and short-circuit protected (INT)
Input current ≤ 9 mA (limited internally)
Switching point according to DIN EN 61131-2 (Type 2)
0 (unattenuated) ≤ 3 mA
1 (attenuated) ≥ 5 mA
Signal delay < 1 ms (input/AS-Interface)
Output
Number/Type 4 electronic outputs, PNP, overload and short-circuit proof
Release date: 2023-03-28 Date of issue: 2023-03-28 Filename: 209759_eng.pdf

Supply from external auxiliary voltage UAUX


Voltage ≥ (UAUX - 0.5 V)
Current 2 A per output, sum 4A (TB ≤ 40 °C)
0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)
2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap)
Usage category DC-13
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Standard conformity
Degree of protection EN 60529:2000
Fieldbus standard EN 62026-2:2013
Input EN 61131-2:2004
Emitted interference EN 61000-6-4:2007
AS-Interface EN 62026-2:2013
Noise immunity EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013

Refer to "General Notes Relating to Pepperl+Fuchs Product Information".


Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 1111 Singapore: +65 6779 9091
www.pepperl-fuchs.com [email protected] [email protected] [email protected] 2
AS-Interface sensor/actuator module VAA-4E4A-KE-ZEJQ/E2L
Technical Data
Ambient conditions
Ambient temperature -25 ... 60 °C (-13 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Relative humidity 85 % , noncondensing
Climatic conditions For indoor use only
Altitude ≤ 2000 m above MSL
Pollution degree 2
Mechanical specifications
Degree of protection IP20
Connection removable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material
Housing PA 66-FR
Mass 150 g
Mounting DIN mounting rail
Tightening torque of clamping screws 0.5 Nm ... 0.6 Nm

Connection

Switch position
"INT" "EXT"
EXT
4 inputs IN1 ... IN4
I+ UEXT
AS-Interface - INT IN
AS-Interface + IN
EXT

I-
INT
for 3-wire for 3-wire
sensors sensors
ADDR

PWR

OUT 4 outputs O1 ... O4


FAULT
O

AUX
Load
Release date: 2023-03-28 Date of issue: 2023-03-28 Filename: 209759_eng.pdf

AUX +
AUX -
O-

Connection
Do not connect inputs and outputs, which are supplied via the module from AS-interface or via auxiliary power, with power supply and signal
circuits with external potentials.

Refer to "General Notes Relating to Pepperl+Fuchs Product Information".


Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 1111 Singapore: +65 6779 9091
www.pepperl-fuchs.com [email protected] [email protected] [email protected] 3
AS-Interface sensor/actuator module VAA-4E4A-KE-ZEJQ/E2L
Assembly

I- 1 I- 2 I- 3 I- 4
IN1 IN2 IN3 IN4 label field
I+ 1 I+ 2 I+ 3 I+ 4

ATT E NT I O N
Do not connect the terminals I+, IN and I- with
any external potential when switch set to "INT" 1 2 3 4
IN
Sensor supply: FAULT INT
INT = internal sensor supply (from AS-i)
EXT = external sensor supply PWR AUX
INT ADDR

1 2 3 4
EXT OUT

O1 O-1 O2 O-2
O3 O-3 O4 O-4
AS-i+ AS-i- AUX+ AUX-

Programming
Data bits
(function via AS-Interface)
Data bit Input Output
D0 IN1 O1
D1 IN2 O2
D2 IN3 O3
D3 IN4 O4

Parameter bits
(programmable via AS-Interface)
Parameter bit Function
P0 Communication monitoring
P0=0 monitoring off, the outputs maintain the status if communication fails
P0=1 monitoring on, if communication fails, the outputs are deenergised, default setting
P1 Input filter
P1=0 input filter on, pulse suppression ≤ 2 ms
P1=1 input filter off, default setting
P2 Lead breakage outputs
P2=0 lead breakage on
P2=1 lead breakage off, default setting
P3 not used

Accessories
VBP-HH1-V3.0-KIT AS-Interface Handheld with accessory
Release date: 2023-03-28 Date of issue: 2023-03-28 Filename: 209759_eng.pdf

VAZ-PK-1,5M-V1-G Adapter cable module/hand-held programming device

VAZ-CHAIN- 25-point wiring link for control cabinet modules with screw terminals
BU/BN70MM/1,0-25

Refer to "General Notes Relating to Pepperl+Fuchs Product Information".


Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 1111 Singapore: +65 6779 9091
www.pepperl-fuchs.com [email protected] [email protected] [email protected] 4