Combination automat

Polyquick 260
Pressure polymerisation unit and compactor

USER MANUAL
Dear customer,

Thank you for choosing a product from the Wassermann range. Wassermann Dental-
Maschinen incorporates the highest standards of quality and the latest technology.
In order to enjoy maximum performance and years of trouble-free operation, please read
this user manual carefully before you connect this device and start work, and operate the
device according to the recommended guidelines. The operation safety and the
functionality of this device can only be guaranteed if you follow both the general safety
guidelines and the applying laws to prevent accidents as well as the precautions given in
this user manual. We are not liable for any damages which occur due to inappropriate
usage or faulty operation of this device.

Make sure that anyone using this device has read and understood this user
manual.
Keep this user manual in a safe place where it can be referred to as required at
any time.

The unit complies with the relevant EC guideline.

The unit is subject to the EC guidelines 2002/96/EG (WEEE Directiv).

Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
D-21031 Hamburg, Germany
Phone : +49 (0)40 / 730 926 – 0 Fax.: +49 (0)40 / 730 37 24
E-mail: [email protected]
URL: http//www.wassermann.hamburg

Erstellt: 20.05.16 / msc Version: 1 Polyquick 260: 170993


Contents
1 Features.............................................................................................................................4
2 Safety guidelines................................................................................................................4
2.1 Safety symbols used in this manual............................................................................4
2.2 Safety guidelines.........................................................................................................5
2.3 Responsibility for operation or damage.......................................................................6
3 Application..........................................................................................................................6
4 Before starting....................................................................................................................7
4.1 Transport.....................................................................................................................7
4.2 Installation...................................................................................................................7
4.3 Storage........................................................................................................................7
5 Installation / Start-up..........................................................................................................8
5.1 Setting the correct pressure........................................................................................8
5.2 Start-up........................................................................................................................9
6 Operation.........................................................................................................................14
6.1 General operating instructions..................................................................................14
6.2 Operation...................................................................................................................15
7 Troubleshooting...............................................................................................................16
8 Care and maintenance.....................................................................................................17
8.1 Cleaning....................................................................................................................17
8.2 Maintenance..............................................................................................................17
8.3 Repairs......................................................................................................................18
8.4 Spare parts................................................................................................................18
8.5 Service hotline...........................................................................................................18
8.6 Scope of delivery / Accessories................................................................................18
8.7 Warranty....................................................................................................................18
9 Technical data..................................................................................................................19
10 Disposing of the unit......................................................................................................20
10.1 Information on disposal for countries within the EC................................................20
11 EC Conformity Certificate..............................................................................................21
1 Features
• Compact table-top unit for pressure polymerisation up to 105°C in a water bath
• Three continuously adjustable polymerisation stages
• Touch screen for fast and easy operation
• The device can also be operated as a pressure compactor
• Rapid draining: prompt switch between the two modes
• Separate menu for each mode
• Intelligent workflow preset by the software helps the user to ensure operational safety
• Remaining time displayed to the second
• Powerful, electronically controlled heating for optimal water temperature
• Very large capacity Ø 240 mm, usable depth 160 mm, suitable for extra large articulators
• Pressure relief valve for protection in case of malfunction (7 bar)
• Safety lid with bayonet lock
• Engraving in container indicating max. water level
• Dry-run protection
• Time and cost saving due to thermal insulation
• Low maintenance, easy to service
• Made almost entirely of stainless steel

2 Safety guidelines

2.1 Safety symbols used in this manual

Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening. These warnings has to
be observed.

Information!
This symbol draws your attention to specific features that has to be observed.

4
2.2 Safety guidelines

Configuring and operating this equipment requires precise knowledge and observance
of the instructions in this user manual. The equipment is designed only for its intended
application.

WARNING:
Servicing and repairs should be carried out only by authorised specialists.
Disconnect the power plug before starting any maintenance work.

Make sure that the equipment is connected to the correct power source.

The safety valve on the pressure tank opens automatically if the operating
pressure is more than 7 bar.

The pressure can be activated only if the door is closed completely, since a
safety door contact is installed.

Dry-run protection, which switches off at 112°C (brown button on the left side of
the device).

Warning: Risk of scalding during the Hot Polymerisation.


Never open the lid while the unit is under pressure !
Never open the lid while the temperature is higher than 97 °C !
Open the lid slowly!
Display information have to be followed !

For safety-related reasons (hot water, pressure), only the valves and hoses
meant for this purpose must be used for draining. If parts of different
design are used / installed (self-made), there is a risk of scalding!

5
2.3 Responsibility for operation or damage

The responsibility for operating the device lies exclusively with the owner or user if said
device is incorrectly serviced, maintained or altered by persons not employed by an
authorised dealer or if the device is used in a manner contrary to its specified purpose.
The unit has to be maintained and operated in accordance with this user manual.
Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the
nonobservance of these instructions.
Warranty and responsibility provisions contained in the sales and supply conditions of
Wassermann Dental-Maschinen GmbH are not extended by these instructions.

3 Application

The Polyquick 260 is a pressure polymerisation unit for hot and cold polymerisation of
plastics. It can be set to a maximum temperature of 105°C and the polymerisation
pressure can be adjusted to a maximum of 5 bar. In automatic mode, the polymerisation
time can be preselected up to 99 hours. It has a particularly large pressure pot volume and
can hence also accommodate extra large articulators or up to 6 brass flasks including
clamp. A touch screen and the newly developed control panel allow the user to set the
relevant parameters quickly and easily using self-explanatory symbols. The Polyquick 260
can also be used as a pressure compactor without heating.

Only use the device for this type of application.

6
4 Before starting

4.1 Transport

Before transporting the unit, ensure that it has been unplugged from the power socket.
Make sure that it is packed correctly in order to avoid accidental damage.

Be sure to check for any transport damage when unpacking the goods. Note
down any damage if found.

4.2 Installation

Open the box, remove the packing materials, and carefully lift out the device and
accessories. Check the included accessories.
The device has to stand horizontally on a steady and even surface.

Install the device in a place where it will not block the working area and the
functionality (take the dimensions into account).

Do not install the unit outdoors or in places without proper ventilation.


Before start-up, be sure the device reaches room temperature.

It is advisable to install the device firmly on the drainage system, since very hot
water can drain off from it. This also simplifies the process of complete
emptying, e.g. for cleaning.

4.3 Storage

If the unit is to be stored for an extended period, protect it from moisture and dust.

7
5 Installation / Start-up

Before commissioning, please install the following connections:


Install the pressure hose included in the scope of supply and provide for an
appropriate outlet.
After setting the workpiece, fill the device with tap water, at most up to the engraving in the
tank. Establish a pneumatic connection of minimum 2 bar. If the pneumatic pipe is long,
pay attention to the hose cross-section (internal diameter min. 6 mm). Every pneumatic
pipe must always have a maintenance unit. Ensure a constant pressure by using the
pressure reducer.
Finally, insert the plug into the socket – make sure that the voltage specification of the
device and the mains network is identical.

Never operate the device without water, since the heating unit immediately
heats up to 60°C or to the preheating temperature when the power switch is
activated. If required, the heating unit can be switched off via the display.

5.1 Setting the correct pressure


Before filling the tank, remove the accessories and set the correct polymerisation
pressure. Proceed as follows (image, see 5.2):

1. Activate main switch (green rocker switch).


2. Close lid.
3. Touch the Pressure key 5 (image, see 5.2). (4.0 bar default).
4. If the pressure is very less (min. 2 bar), increase the pressure (max.5 bar) using the
black regulator on the back side. Release the regulator by pulling to do the setting
and press it in once again.
5. If the pressure is too high, switch off the pressure 5 (image, see 5.2) and release
the pressure. Turn the pressure regulator on the back side in the "minus" direction
several times; then, apply pressure to the tank. You can set the desired pressure by
turning the regulator in the "plus" direction (max. 5 bar)

8
5.2 Start-up

Define the unit's main parameters before switching it on. These settings are performed in
the Set-Up Menu 3 . Familiarise yourself with the system's various options before
starting the polymerisation process. This particularly applies to functions 7 and 14 .
(Please see „setup menu page 1“ on page 10 of this manual).

The Start menu in Polymerisation mode

Name of the unit Actual-Temperatur Open Setup menu


1 2 3

4 5 6
Heater ON/OFF* Pressure ON/OFF* Program parameter and
Polymerisation
*Inverted (background is black) = ON

The Start menu in Compactor mode (without heater)

9
Setup menu page 1

In the Setup menu the following settings can be made:

7 Preheating temperature 8 Clock timer 9 Forward in menu

10 11 16
Sleep Heater ON/OFF back to Start menu
Mode: Polymerisation / Compaction without heater

Setup menu page 2

°C/°F Date and Time Forward in menu


12 13 9

14 15 16
Work mode Information back to Start menu

10
Description of features 5 – 14

5 Pressure ON/OFF

Bevore starting the program you have to choose the pressure.

6 Program parameter und Polymerisation

Defines the parameters for the program temperature. Touch the numbers to change the
values. Up to three polymerisation stages #1-3 can be mapped.

Polymerisation level 1:

Delete Next step Save

Examples of level 2 and level 3: Start

Touch the arrow (Start) to start the process of polymerisation. Pause or cancel the
program by pressing the "Stop/Pause"symbol.

11
The Polymerisation

Stop/Pause Break-of Pause Back Start

7 Preheating temperature

Defines the target temperature once the main switch has been activated. The pre-heat
temperature also applies to waiting times and rest periods. Default: 60°C

If the programme temperature selected is higher, the temperature reverts back


to this value when the programme ends.

After defining the desired working mode 14 , it may make sense to adjust the pre-heat
temperature of the programme temperature. This avoids long heat-up or cool-down
phases.

8 Clock timer

This defines the weekday activation and deactivation times.

12
Programs running currently have a higher priority; they are not switched off until complete.

10 Sleep button display

When you press the Sleep button, the device goes into the Sleep mode (all functions
except the Timer function are switched off). The device gets actuated when you press the
touch display or with the timer and heats up or cools down to the preset pre-heating
temperature.

11 Heater ON/OFF

Choosing the pressurepolymerisation mode (pressure and temperature) or Compactor


mode (pressure without heater).

12 Selection of the temperature unit (Fahrenheit or Celsius)

13 Pictograms for the time and date function cycle.

13
14 Selection of the working mode

Defines whether the polymerisation process should start immediately or only after the
heating value has been reached.

(a) (Default) The device heats to the temperature programmed under 6 . After reaching
this value, the result measured is validated by a control cycle. If the value is confirmed, the
wax polymerisation process will start.

(b) The programmed polymerization begins immediately.

15 Information

Here the parameters of the touch screen, sensors, hardware and software are displayed.

6 Operation

6.1 General operating instructions

All instructions for using the unit, whether in verbal or written form, are based on our own
experience and experimentation and can only be regarded as guidelines.

14
Please put on heat-resistant gloves

During longer periods of non-use please disconnect the power plug.

6.2 Operation

• Open the lid.


• First set the workpieces, then fill the water till all the polymerisation parts are
covered (max. up to the engraving = Marking in the tank) and close the lid up to the
stop.
• Switch on the main switch, the device will automatically heat up to 60°C or up to the
value selected as the pre-heating temperature. If warning A appears, close the
lid.
• Activate the pressure. 5
• The process of polymerisation starts when you touch the symbol 6 . After the
process of polymerisation has ended, the temperature falls/rises to the preset
temperature again.

5 6 A

15
7 Troubleshooting

Fault Cause Remedy


Polyquick 260 Lid is open (Fig. 1) Close lid against safety contact.
does not heat
Temperatur-programm- Adapt the parameters.
parameter is to low
Preheating temperature Adapt the parameters.
is to low
Heater faulty Please contact our service department.
Pressure does Lid seal O-ring faulty Check O-ring and replace if necessary.
not increase in
chamber Pressure regulator set to 0 Check pressure and adjust if necessary.
(pressure gauge).
Lid not fully closed Close lid against safety contact or
contact faulty.
Temperature monitor off or faulty Press in safety knob (left side of unit)
and/or replace knob. Please contact our
service department.
Display blank Temperature monitor off or faulty Press in safety knob (left side of unit)
and/or replace knob. Please contact our
service department.
Touchscreen Calibrate the touch display Switch on the unit. While the logo of
malfunction Wassermann appears please contact
the touch display two times.
Then you will reach the self-explanatory
touch panel-calibration (Fig. 2-3).
Touchscreen under pressure Please contact our service department.
Screen protector damaged? Please contact our service department.
Unit does Blown fuse Replace fuse at rear of unit.
nothing

If the above recommendations do not solve the problem, contact your dental
depot or our service department.

Fig. 1 Fig. 2 Fig. 3

16
8 Care and maintenance

8.1 Cleaning

Disconnect the power plug before starting any maintenance work.


The identification plate has always to be kept in easily legible condition and has
not to be removed.

Remove external dirt from time to time with some form of cold cleaner.
Use only cold cleaners to avoid damaging the paintwork or removing the lettering.

8.2 Maintenance

At regular intervals, check the cover gasket (item no. 380063) for damages; for this
purpose, remove the gasket ring (reddish brown silicon ring) from the ring groove of the
pressure tank using a pair of blunt tweezers. The ring groove for holding the gasket ring
must always be kept clean.
Use Vaseline or oil while inserting the gasket ring back into the ring groove.

Check the functioning of the lid safety switch by opening and closing the lid multiple times;
a soft click must be audible while closing or opening.

Change the sealing ring every 18 months.

17
8.3 Repairs

Servicing or repairs to the unit has only to be carried out by qualified technicians.
Only original spare parts are to be used. Responsibility for the product is voided
if unauthorised persons alter it or if inappropriate components are installed.

8.4 Spare parts

If necessary please contact our service hotline phone.

8.5 Service hotline


0049 (0)40 / 730 926 – 0

8.6 Scope of delivery / Accessories

Included parts Item no.


Flask bracket support 170414
Compressed air hose, 2 m 320026
Discharge hose, 2 m 320021
Fuse 6,3 AM/250 V D 5 x 20, 2 pcs. ---

Accessories/Spare parts Item no.


Flask bracket support 170414
Compressed air hose per meter 320026
Discharge hose per meter 320021
On request: flask basket as special accessory ---
Fuse 6,3 AM/250 V D 5 x 20, 2 pcs. 582013

8.7 Warranty

The warranty period for our equipment is 12 months. If faults occur within the
warranty period, contact your dental depot or get in touch directly with our service
department.
Your equipment should only be operated in perfect condition. If faults occur which
could harm operators or third parties, the unit should not be used until it has been
fixed.
This warranty does not cover damage caused by improper use, external mechanical
causes, transport damage or interference with the unit by unauthorized persons.

18
9 Technical data

Polyquick 260 Item no.: 170993


Voltage* 220–240 V / 50/60 Hz
Power consumption 4,3 A
Output 1100 W
WxHxD 421 x 437 x 485 mm
Weight 36,8 kg
Compressed air connection min. 2 bar
Operating pressure max. 5 bar
Pressure chamber Ø 240 mm, depth 175 mm (usable depth 160 mm)

The noise level of the unit amounts to ≤ 70 dB (A).


*Other voltages on request.
Technical changes reserved.

19
10 Disposing of the unit

The unit has to be disposed by an authorized recycling operation. The selected company
has to be informed of all possibly health-hazardous residues in the unit.

10.1 Information on disposal for countries within the EC

To conserve and protect the environment, prevent environmental pollution and


improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling.
Within the European Union units with this symbol should not therefore be disposed of
in unsorted domestic waste.
For more information regarding proper disposal please apply at your local authoritie.

20
11 EC Conformity Certificate
in accordance with 2006/95/EG (low-voltage guidelines) and 2004/108/EG (EMV
guidelines) and 2006/42/EG (machinery guidelines)
Manufacturer: WASSERMANN Product description: Polishing compact
Dental-Maschinen GmbH unit for dental
Rudorffweg 15 - 17 applications
D-21031 Hamburg
Model: Polyquick 260 Item no. 170993

Applicable DIN EN 61010-1


standards: DIN EN 61000-6-3
DIN EN 61000-6-1
DIN 45635-1
DIN EN 60335-1

Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EG-Richtlinien
entspricht. Diese Erklärung wird ungültig, falls die Maschine ohne unsere Zustimmung
verändert wird.

This is to confirm that the above mentioned machine complies with the described EC
rules. This declaration becomes invalid if the machine is modified without our approval.

Cette machine est conforme aux normes en vigueur de la Communité Européene. Cet
avis est nul et non avenant si cette machine est modifiée sans notre accord.

Esta máquina, anteriormente mencionada, cumple con los limites requeridos por el
reglamento EC. Ahora bien, esta declaración quedará invalidada en caso de realizar
modificaciones al aparato sin nuestra aprobación.

Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven


EU normen. Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke
toestemming wijzigen aan de machine worden aangebracht.

Place, date: Hamburg, 20.05.2016 Company stamp:

Signature : ________________________
Wilfried Wassermann
(Managing Director)

21