IPP15 Application Note
IPP15 Application Note
Sold by:
coverage area (900 sq ft) within the set time out limit. There are four TIME
3
RANGE
10
still detected after adjusting the blinders you may want to reduce 1 2 4 7
Slash Mark
Figure 1
INSTALLATION CONSIDERATIONS 3-Way Wiring Diagram for IPP15 with Sensor Remote.
Up to 5-Way Control
WALLBOX IPP0R Remote IPP15
• An extended depth wallbox is recommended for installing the
WH BK WH
IPP15 device. For proper mounting of device there must be Hot (Black) BK
WIRING DIAGRAM FOR IPP15 NOTE: The IPP15 must be installed in a wallbox that has a Load connection.
The matching remote must be installed in a wallbox with a Line Hot connection
• IPP15 is a single-pole or 3-Way circuit switch that requires a and a Neutral connection. A Neutral wire to the matching remote needs to be
added as shown.
Neutral (white) wire connection. There must be a neutral wire
present in the wallbox for the device to operate correctly. IPP15 with VZ0SR-1L Vizia Matching Switch Remote or
Coordinating Switch Remote
Single Pole Wiring Diagram An IPP15 and a Vizia remote can be used for true 3-Way control
for small rooms (<900 sq ft) where the sensor can view the
IPP15 entire room without obstructions.
Example: Jack and Jill Bathroom
WH BK Hot (Black)
In a Jack and Jill bathroom application you may have more than
Green
Ground one entrance to the bathroom with a switch at either entrance.
RD YL/RD (unused) This application could be wired using an IPP15 remote at one
Black entrance and a Vizia remote at the other. This would allow control
Line
Load 120VAC, 60Hz of the load at either end in addition to having occupancy control
in the bathroom.
White
3-Way Wiring Diagram for IPP15 with Vizia Matching
Neutral (White)
Switch Remote. Up to 5-Way Control
Wiring this device in a 3-Way application offers various different Hot (Black) WH WH
scenarios depending on the size or layout of your room. Areas that BK BK
may require 3-Way control are bathrooms, basements, garages, Green
Ground
Green
Ground
Black
utility/laundry rooms, hallways, bedrooms, and kitchens. Your Line YL/RD RD YL/RD
Load
sensor may be located in an area that does not cover the entire 120VAC, 60Hz
room, this could be depending on the way the switch is facing in
White
the room, or the size of the room exceeds the sensors 900 sq ft
coverage area. In either instance, a 3-Way circuit can improve your Neutral (White)
range of coverage and control. Leviton’s IPP15 occupancy sensor
allows you to wire any 3-Way circuit with either an IPP0R sensor NOTE: The IPP15 must be installed in a wallbox that has a Load connection.
remote or any of Leviton’s Vizia™ remote switches. The matching remote must be installed in a wallbox with a Line Hot
connection and a Neutral connection. A Neutral wire to the matching remote
needs to be added as shown.
Maximum wire length from IPP15 to all installed remotes cannot
exceed 300 ft (90 m).
IPP15 with IPP0R Matching Sensor Remote
The IPP15 with the IPP0R provides true 3-Way control for
large rooms where the sensor does not have coverage of the
entire room.
Example: L shaped room, Great Room
3-Way Wiring Diagram for IPP15 with Vizia Coordinating LOCATION OF IPP15
Switch Remote. Up to 10-Way Control
For All Locations
ViziaTM Coordinating Switch IPP15 • The IPP15 PIR sensor operates on a line-of-site principle,
Remote (no LED) so it must have a clear, unobstructed view in order to
WH BK
(unused)
WH Hot (Black) detect occupancy.
BK
Green Green • Install at least 6 feet away from a climate control source (i.e.
Black Ground Ground
radiators, air exchangers , air conditioners, etc.). Hot or cold
RD YL/RD YL/RD
(unused)
RD Line drafts can appear to the sensor as body motion.
Load 120VAC, 60Hz
• Do not install directly under a lighting source that is 100 watts
White or greater. Temperature changes can be detected by the device.
• The IPP15 can be used for switching incandescent and
Neutral (White)
fluorescent and low voltage lighting with electronic or magnetic
NOTE: The IPP15 must be installed in a wallbox that has a Line Hot connection. ballasts.
Kitchen
Vizia Dimmer with IPP0R Matching Sensor Remote
• Do not install IPP15 near a stove or appliance that generates
A Vizia dimmer can be used with an IPP0R sensor remote for true heat.
3-Way control of small rooms (<900 sq ft) where the sensor can • Install the IPP15 in a location where it will NOT sense motion
view the entire room without obstructions. This adds dimming from an adjoining room (i.e. dining room, great room or family
functionality. The Vizia dimmer or the IPP0R can be turned ON full room).
bright from the OFF position by pressing and holding the push
pad. It also has a 10 second delayed off feature that can be Bathroom
activated from the ON position by pressing and holding the push • Make certain a shower curtain or glass shower door do not
pad of the dimmer or the IPP0R until the LED starts blinking. obstruct the field of view.
Example: Master Bedroom • Consider programming the IPP15 with the maximum time out
In addition the IPP0R sensor remote can be used as a remote period of 30 minutes before the lights will automatically turn
sensor to any Vizia dimmer or switch device. Below is a scenario OFF. If you spend more than 30 minutes regularly in the
where this application might apply. bathroom, consider installing a Leviton dimmer instead.
3-Way Wiring Diagram for IPP0R with Vizia Dimmer. • Some bathrooms are designed with more than one entrance,
Up to 5-Way Control which is often described as the “Jack and Jill” bathroom,
application. For this scenario, the IPP15 can be wired in a
3-Way application.
IPP0R Remote Vizia Dimmer
Bedroom
WH BK WH BK
Hot (Black) • Make certain the blinders are set for full open (default setting).
Green Green
Ground Ground
Black • Consider programming the IPP15 with the maximum time out
period of 30 minutes before the lights will automatically turn
Line YL/RD RD YL/RD
120VAC, 60Hz
LOAD OFF. If you spend more than 30 minutes sitting still at a
computer, watching TV, or reading, you should consider
White installing a Leviton dimmer instead.
Neutral (White) Laundry/Utility Room or Garage
• A short time out setting is recommended
NOTE: The Vizia dimmer must be installed in a wallbox that has a Load
connection. The matching remote must be installed in a wallbox with a Line
Hot connection and a Neutral connection. A Neutral wire to the matching LED INDICATORS
remote needs to be added as shown.
IPP15 is designed with an LED locator within the manual push
button. Depending on the state of the device this LED will
respond accordingly.
Lights OFF & NO motion = LED ON
Lights OFF & motion detection = LED ON
Lights ON & NO motion = LED OFF
Lights ON & motion detection = LED Blinks