JP-21E

60Hz 1800rpm IP 120/240V


STANDARDS
Model JP-21E
Genset: GB/T2820-2009, ISO8528
Power(ESP) kW/kVA 20/20 Alternator: VDE0530,NEMA MG 1-32, IEC34, AS1359
Power(PRP) kW/kVA 19/19 Diesel Engine: ISO3046, DIN6271
StandbyPower: Continues running at variable load for duration
Rated Voltage V 120
of an emergency. No overload is permitted on these ratings.
Rated Current A 92 Prime Power: Continues running at variable load for unlimited
periods with 10% overload available for 1 hours in any 12 hours
Rated rotation speed r/min 1800
period.
Power Factor Pf 1
CONFIGURATION
Standard: Engine, alternator, cooling system,
Base frame (excluding fuel tank), shock absorber,
Frequency Hz 60
air inlet system, control box (including mains
Fuel Consumption L/h 3.1 (50%) 4.6 (75%) 6.2 (100%) 6.9 (110%) floating charge), plastic fan blades (when the
engine and water tank do not bring).
Phase No 1-phase
Optional: Base frame (including fuel tank),
Insulation Grade H water jacket heater, fuel water separator, fuel
Pole Number 4 heater, fuel level sensor (only supporting
underframet tank), switch box (with switch),
Excitation Mode Self-excitation power switch, the water level sensor, motor anti
Panel Type Digital Panel condensation heater, automatic fueling system
(only supporting base frame including fuel tank),
Performance G3/G3
battery frame.
Grade
Accessories: Silencer, bellow, exhaust silencing
Open Type 94 ± 2 system accessory (with the matching engine),
Noise Level (Db) regular battery staring cord assembly, data of
Silent Type 64 ± 2
genes, random tool (with the matching engine).
Engine:

Engine Manufacturer Perkins


Engine Mode 404D-22G
Engine Type 4 stroke; In-line; 3 cylinder Diesel
Air intake way Naturally aspirated
Engine Cyl. 4
Cylinder Bore mm 84
Stroke mm 90
Displacement L 2.2
Rated Power KW/HP 22/30

Compression Ration 5:1

Fuel System Mechanical Direct injection


Coolling System Water cooled
Lubrication System Pressure splashed
Starting System Electrical Starting
Fuel Type To confirms to USA Fed Off Highway
Lube oil Brand 15W40-CH4 Upgrade
Capacity of cooling Water L 6.0L

Lube Capacity L 11.0L

Stating Voltage V DC 12V

Alternator:
Alternator Manufacturer Stamford
Alternator Model PI 144G
Control System AVR
Insulation System Class H
Alternator Protetion IP44
Rated Power Factor 0.8
Stator winding Standard No.6
Temperature grade H
Voltage Regulation ±0.5%
Satisfying Standardization IEC600034,NEMA MG1.22,ISO 8528,CSA,UL 1446,UL1004B
Control System:

132*64 LCD display with


backlight, optional language
interface (Chinese, English,
Spanish and Russian), push-
button operation;

- Acrylic screen, improved wearable and scratch resistance property;


- Silica-gel panel and keys can well adapt to higher and lower
temperature;
- With RS485 communication port, can achieve “three remote” functions via MODBUS protocol;
- Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system;
- Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens;
- Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/
under frequency and over current;
- Precision measure and display of parameters about engine,
- Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and
protection;
- With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output;
- Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot
be lost even when power off. All of parameters can be set not only from the front panel, but also use programmable
interface (or PS485 interface) to adjust them via PC.;
- Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user;
- Multi conditions of crank disconnect (speed sensor, oil pressure, generator) can be selected;
- Power supply range: (8~35)VDC, accommodating to different starting battery volts;
- All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having
improved reliability and stability;
- Add rubber gasket between shell and controller screen, the waterproof can reach IP55;
- Controller is fixed by metal fixing clips;
- Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation.

TECHNICAL SPECIFICATIONS:
Display LCD(132*64)
Operation Panel Silicon Rubber
Language Chinese & English & Others
Digital Input 5
Relay Output 6
Analogue Input 3
AMF
AC System 1P2W/2P3W/3P3W/3P4W
Alternator Voltage (15~360)V(ph-N)
Alternator Frequency 50/60Hz
kW/Amp Detecting & Display
●Monitor Interface LINK
Programmable Interface LINK
Maintenance
DC Supply DC(8-3
Case Dimensions(mm) 197*152*47
Panel Cutout(mm) 186*141
Operating Temp. (-25~+70)℃
Silent Type
Weight & Dimension:

L inches 78 3/4”

W inches 33 1/2”

H inches 63”

Weight pounds 3,500