REV 2.

Camera VIDEO OUT


#20 IN1G
VIDEO
CAMERA RCB PDB VIDEO
SWITCHER OUTG #21
#19 PDB IN2G
#18 IN-ROOM

System Interfaces
Monitor
M.P.U. RTEB
Appendix B:

(PC) SVGA

#22
Power
RCB L.I. X-ray
Console
KEYPAD Monitor
RS-232

#39
CMT Medical Technologies Ltd.

KEYPAD

IRIS control
POWER

MPU.GND
D2

Camera GND
MPU.Power

Camera Power
MONITOR
KEYBOARD

#13
x3 VGA
#16
W.S.

#34

#9
#4
#10
#36
#11
KEYPAD 1 #17 MONITOR

x4 MOUSE

#12
x3
ADR System Interconnection Diagram

KEYPAD 2
SYSTEM INTERFACES

RoomInterfaces
#32
#25
HOST
#26
SYSTEM Transformer PDU (RACK)
#27 #7
#40

Figure Appendix B- 1: ADR System Interconnection


#1
#2
NOTES:
1. For cable catalog number crosscheck refer
MAIN MAIN
to interconnection cable list and to Field 230VS OR POWER & GND
GROUND
Replaceble Units (FRU) list. 115V DC POWER
2. Some of the indicated items are optional CONTROL & DATA
and/or may not be supplied by CMT. Refer to FIBER OPTIC
your system packing list for your exact system Video
configuration.
ADR-1000A Maintenance Manual

B-1
CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

Video Switcher Interconnection

IRM
PDU

MPU
CCU

PDB

RDL TX - AVX
AUTO VIDEO SWITCHER
12 - 24V
AC OR DC
INPUT AUX
POWER SLAVE OUTPUT
INPUT
FAULT

Figure Appendix B- 2: Electrical Connection In room keypad to review console.

System Interfaces B-2


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

Main systems interconnection

ADRK-006A
PC PROCESSOR
P5 DR/A1 DR/T1
9 <--- +5V FLREQ- <--- 20
2 ---> RXD RPOS- ---> 6
3 <--- TXD +24V <--- 24,25
5 <--- GND FPOS- ---> 19
DR/A2 FLGNT- ---> 5 TABLE CONTROL BOX
0V REF ---> 8,7
EXPREQ- <--- 9 COLLIMATOR PWB
1,29-26 <--- +15V OUT
34 <--- FLREQ- PREPACK- ---> 17 CNN EPS2
3 <--- PREPREQ- PREPREQ- <--- 21
4 <--- EXPREQ- EXPACK- ---> 4
ADR I/F RACK 5 <--- PF-RATE0- ( SPARE ) <--- 14
6 <--- PF-RATE1- ( SPARE ) <--- 15
7 <--- PF-MODE- ( SPARE ) <--- 16
ANALOG I/O (IOB2) 8 <--- SYSTEM-STANDBY- ( SPARE ) ---> 1
9 <--- SPOTVIEW- ( SPARE ) ---> 2
VHREF <--- 2 10 <--- LIH- I/O-2 PWB
GND <--- 10 11 <--- RAD-EXP-ON- DR/T2 CNN EPS1
VREF <--- 3 12-15,17,48 --- 0V
GND <--- 11 28 ---> PREPACK- VH.REF <--- 2
HREF <--- 4 29 ---> EXPACK- V.REF <--- 3 NOT USE
GND <--- 12 31 ---> FLGNT- H.REF <--- 4
30 ---> PF-XRAY-TRG- 0V <--- 10,12 CNN DR2
33 ---> FPOS-
DR/T3
PORT A 35 <--- AIC-SIG +15V <--- 12,11,9
36 <--- GND( AIC-SIG ) TILT2- <--- 13
FLREQ <--- 1,34 TILT1- <--- 14
<--- 18, 2 40 ---> ( SPARE )
41 ---> ( SPARE ) TILT0- <--- 15
PREPREQ <--- 19, 3 42 <--- ( SPARE ) DIV0- <--- 2
EXPREQ <--- 20, 4 43 <--- ( SPARE ) DIV1- <--- 4
PF_RATE0 <--- 21, 5 45 ---> DR-OK-(ADR-ACTIVE-) DR_SELECT <--- 5
PF_RATE1 <--- 22, 6 46 ---> INJECTOR- COMP- <--- 6
PF_MODE <--- 23, 7 47 ---> RPOS- SERIAL- <--- 8
SYSSTDBY <--- 24, 8 50 (+15V IN) ( SPARE ) <--- 7
SPOTVLIH <--- 25, 9 I/F+15V ---> 10
FL LIH <--- 26,10 DR/A3 SERIAL I/F PWB
DR-OK-(ADR-ACTIVE-) ---> 1
---> 27,11 ( SPARE ) ---> 3 CNN DR1
PREPACK ---> 28,12 1,2,14 <--- +15V OUT
EXPACK ---> 29,13 9 <--- DIV0- VD/T
---> 30,14 22 <--- DIV1- +15V IN <--- 4
10 <--- DIV2-(DR-SELECT-) NOT USE FOR
FLGNT ---> 31,15 SPOTVIEW- <--- 5 THIS SYSTEM
PF.TRIG P ---> 32,16 5 <--- ( SPARE ) LIH- <--- 16
F_POS ---> 33,17 18 <--- ( SPARE ) AIC-SIG <--- 1
R_POS ---> 47,48 7 ---- (+15V IN) GND(AIC-SIG) <--- 8
---> 49,50 3 ---> ( SPARE )
16 ---> ( SPARE ) DR/OPT JUNCTION UNIT (MAX-1000A/E1)
PORT C VD/ADR1 MLT ---> JUNCTION I/F PWB
F_CODE1 <--- 9,2 <--- CNN 6CJ
9 <--- ( SPARE )
F_CODE2 <--- 11,4 1,2 <--- +15V OUT DR/O
DR_SELECT <--- 12,5 6 <--- R.READY-
7 <--- R-XRAY-IN- +24V ---> 19,18,6
3 ---- (+15V IN) F1-ON- ---> 20,7
PORT D 8 ---> INJECTOR- F2-ON- ---> 21,8
READY <--- 1,6 5 ---> ( SPARE )
EXON <--- 2,7 4 ---> 0V
INJ ---> 8,4 DR/X
9,5 VD/ADR2 +5V ---> 9 X-RAY CONTROL KXO-80M
RXD <--- 2 CNN25
PORT B 1,2 <--- +15V OUT TXD ---> 3
9 <--- H.REV- GND ---> 5
H.REV <--- 1, 9 10 <--- V.REV-
V.REV <--- 2,10 6 <--- ( SPARE )
(DOSE_1) <--- 3,11 DR/X2
7 <--- ( SPARE ) +15V <--- 12, 5,4
(DOSE_2) <--- 4,12 15 ---- (+15V IN)
ADR-ACTIVE ---> 5,13 AIC-SIG <--- 11,10,3 CNN21
3 ---> ( SPARE ) GND(AIC-SIG) <--- 9, 2,1
6,14 4 ---> ( SPARE ) +24V <--- 14, 7,6
5 <--- 0V F1-ON- <--- 15
PORT E 13 ---> ADR-ACTIVE- F2-ON- <--- 8
+/- ABC ---> 5 VD/ADR3
-/+ ABC ---> 1 CNN14
AGND-ISO ---> 3 5 ---> ABC OUT VD/AEC
3 ---> GND CONT +15V <--- 19
ABC ---> 3
AEC_VIDEO ---> 1
GND(AEC) ---> 2
AEC_VD- ---> 5 MTV I/F
AEC_CP ---> 6
AEC_HD- ---> 7
CONT_GND <--- 16,14
CONT-15V <--- 20
AEC GATE <--- 10
GATE RETURN <--- 11
( SPARE ) <--- 13
VD/VTR ( SPARE ) <--- 18
NOT USE BNC ( SPARE ) ---> 22
SYSTEM-STANDBY- <--- 12
MONITOR (IRM) R.READY- <--- 4
VIDEO OUT VD/CRT1 R-XRAY-IN- <--- 9
INJECTOR- ---> 17
BNC BNC 0V REF ---> 21
GND(FG) <--- 24,23
VD/CRT2 VD/CONT
NOT USE BNC +15VI <--- 9
H.REV- <--- 6
V.REV- <--- 8
PF-RATE0- <--- 10
PF-RATE1- <--- 11
PF-MODE- <--- 12
( READY- ) <--- 17
( F-ON- ) <--- 18
( SPARE ) <--- 2
( SPARE ) <--- 3
+15VO ---> 24
ADR-ACTIVE- ---> 22 SYSTEM CONNECTION DIAGRAM
PF-TRIGGER-PULSE- ---> 23 FOR
( SPARE ) ---> 14
( SPARE ) ---> 15 KXO-80M / MAX-1000A / ADR-1000A

Figure Appendix B:-1: Main systems interconnection – configuration 1

System Interfaces B-3


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

ADRK-006A
PC PROCESSOR TABLE CONTROL BOX
P5 DR/A1 DR/T1 MOTHER BOARD
9 <--- +5V FLREQ- <--- 20 CNN EPS/AUX
2 ---> RXD RPOS- ---> 6
3 <--- TXD +24V <--- 24,25
5 <--- GND FPOS- ---> 19
DR/A2 FLGNT- ---> 5 CNN AI
0V REF ---> 8,7
1,29-26 <--- +15V OUT EXPREQ- <--- 9 18 <--- FLREQ-
34 <--- FLREQ- PREPACK- ---> 17 4 ---> RPOS
3 <--- PREPREQ- 3 <--- +24V
PREPREQ- <--- 21 6 ---> FPOS
4 <--- EXPREQ- EXPACK- ---> 4
ADR I/F RACK 5 <--- PF-RATE0- 19 ---> FLGNT-(BI)
6 <--- PF-RATE1- ( SPARE ) <--- 14 5,7 <--- I/F 0V
7 <--- PF-MODE- ( SPARE ) <--- 15 etc...
ANALOG I/O (IOB2) 8 <--- SYSTEM-STANDBY- ( SPARE ) <--- 16
9 <--- SPOTVIEW- ( SPARE ) ---> 1 CNN BI
VHREF <--- 2 10 <--- LIH- ( SPARE ) ---> 2 10 <--- FLGNT-(BI)
GND <--- 10 11 <--- RAD-EXP-ON- DR/T2 11 ---> FLGNT-
VREF <--- 3 12-15,17,48 --- 0V 5 <--- EXPREQ-
GND <--- 11 28 ---> PREPACK- VH.REF <--- 2 19 ---> PREPACK-
HREF <--- 4 29 ---> EXPACK- V.REF <--- 3 NOT USE 8 <--- PREPREQ-
GND <--- 12 31 ---> FLGNT- H.REF <--- 4 17 ---> EXPACK-
30 ---> PF-XRAY-TRG- 0V <--- 10,12 4,7,29,30,31,32 <--- I/F 24V
33 ---> FPOS- DR/T3 18,20,24,25,26,27 <--- I/F 0V
PORT A 35 <--- AIC-SIG +15V <--- 12,11,9 CNN OPT2
FLREQ <--- 1,34 36 <--- GND( AIC-SIG ) TILT2- <--- 13
<--- 18, 2 40 ---> ( SPARE ) TILT1- <--- 14
PREPREQ <--- 19, 3 41 ---> ( SPARE ) TILT0- <--- 15
EXPREQ <--- 20, 4 42 <--- ( SPARE ) DIV0- <--- 2
43 <--- ( SPARE ) DIV1- <--- 4 CNN MTV
PF_RATE0 <--- 21, 5 45 ---> DR-OK-(ADR-ACTIVE-) DR_SELECT <--- 5
PF_RATE1 <--- 22, 6 46 ---> INJECTOR- COMP- <--- 6
PF_MODE <--- 23, 7 47 ---> RPOS- SERIAL- <--- 8
SYSSTDBY <--- 24, 8 50 --- (+15V IN) ( SPARE ) <--- 7
SPOTVLIH <--- 25, 9 I/F+15V ---> 10
FL LIH <--- 26,10 DR/A3 DR-OK-(ADR-ACTIVE-) ---> 1
---> 27,11 ( SPARE ) ---> 3
PREPACK ---> 28,12 1,2,14 <--- +15V OUT
EXPACK ---> 29,13 9 <--- DIV0- VD/T DIAGNOSTIC TABLE
---> 30,14 22 <--- DIV1- I.I.TUBE
FLGNT ---> 31,15 10 <--- DIV2-(DR-SELECT-) +15V IN <--- 4
PF.TRIG P ---> 32,16 5 <--- ( SPARE ) SPOTVIEW- <--- 5 MODE
F_POS ---> 33,17 18 <--- ( SPARE ) LIH- <--- 16
R_POS ---> 47,48 7 ---- (+15V IN) AIC-SIG <--- 1
---> 49,50 3 ---> ( SPARE ) GND(AIC-SIG) <--- 8
16 ---> ( SPARE ) DR/OPT
PORT C VD/ADR1 MLT ---> NOT USE FOR OPTICAL SYSTEM
F_CODE1 <--- 9,2 9 <--- ( SPARE ) <--- THIS SYSTEM ND FILTER
F_CODE2 <--- 11,4 1,2 <--- +15V OUT DR/O
DR_SELECT <--- 12,5 6 <--- R.READY-
7 <--- R-XRAY-IN- +24V ---> 19,18,6
PORT D 3 ---- (+15V IN) F1-ON- ---> 20,7
8 ---> INJECTOR- F2-ON- ---> 21,8
READY <--- 1,6 5 ---> ( SPARE )
EXON <--- 2,7 4 ---> 0V DR/X
INJ ---> 8,4
9,5 VD/ADR2 +5V ---> 9 X-RAY CONTROL KXO-80M
PORT B 1,2 <--- +15V OUT RXD <--- 2 CNN25
9 <--- H.REV- TXD ---> 3
H.REV <--- 1, 9 10 <--- V.REV- GND ---> 5
V.REV <--- 2,10 6 <--- ( SPARE ) DR/X2
(DOSE_1) <--- 3,11 7 <--- ( SPARE )
(DOSE_2) <--- 4,12 15 ---- (+15V IN) +15V <--- 12, 5,4
ADR-ACTIVE ---> 5,13 3 ---> ( SPARE ) AIC-SIG <--- 11,10,3 CNN21
6,14 4 ---> ( SPARE ) GND(AIC-SIG) <--- 9, 2,1
5 <--- 0V +24V <--- 14, 7,6
PORT E 13 ---> ADR-ACTIVE- F1-ON- <--- 15
+/- ABC ---> 5 VD/ADR3 F2-ON- <--- 8
-/+ ABC ---> 1 VD/AEC CNN14
AGND-ISO ---> 3 5 ---> ABC OUT
3 ---> GND CONT +1 <--- 19
ABC ---> 3
AEC_VIDEO ---> 1
GND(AEC) ---> 2
AEC_VD- ---> 5 MTV I/F
AEC_CP ---> 6
AEC_HD- ---> 7
CONT_GND <--- 16,14
CONT-15V <--- 20
AEC GATE <--- 10
GATE RETURN <--- 11
( SPARE ) <--- 13
VD/VTR ( SPARE ) <--- 18
NOT USE BNC ( SPARE ) ---> 22
SYSTEM-STANDBY- <--- 12
MONITOR (IRM) R.READY- <--- 4
VIDEO OUT VD/CRT1 R-XRAY-IN- <--- 9
BNC BNC INJECTOR- ---> 17
0V REF ---> 21
GND(FG) <--- 24,23
VD/CRT2 VD/CONT
NOT USE BNC +15VI <--- 9
H.REV- <--- 6
V.REV- <--- 8
PF-RATE0- <--- 10
PF-RATE1- <--- 11
PF-MODE- <--- 12
( READY- ) <--- 17
( F-ON- ) <--- 18
( SPARE ) <--- 2
( SPARE ) <--- 3
+15VO ---> 24 SYSTEM CONNECTION DIAGRAM
ADR-ACTIVE- ---> 22
PF-TRIGGER-PULSE- ---> 23 FOR
( SPARE ) ---> 14 KXO-80M / "A" TABLE / ADR-1000A
( SPARE ) ---> 15

Figure Appendix B:-2: Main systems interconnection – configuration 2

System Interfaces B-4


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

X-RAY R/F TABLE DUA-450D


ADRK-006A TABLE BASE
PC PROCESSOR I/O PWB
P5 DR/A1 DR/T1 CNN EPS
9 <--- +5V +24V <--- 24,25
2 ---> RXD PREPREQ- <--- 21
3 <--- TXD EXPREQ- <--- 9
5 <--- GND FLREQ- <--- 20
( SPARE ) <--- 14
DR/A2 ( SPARE ) <--- 15
1,29-26 <--- +15V OUT ( SPARE ) <--- 16
34 <--- FLREQ- PREPACK- ---> 17
3 <--- PREPREQ- EXPACK- ---> 4 SPOT FILM DEVICE
4 <--- EXPREQ- FLGNT- ---> 5 DRIVE PWB
ADR I/F RACK 5 <--- PF-RATE0- FPOS- ---> 19 CNN MIR
6 <--- PF-RATE1- RPOS- ---> 6
7 <--- PF-MODE- ( SPARE ) ---> 1 3 ---> RPOS
ANALOG I/O (IOB2) 8 <--- SYSTEM-STANDBY- ( SPARE ) ---> 2 4 ---> FPOS
9 <--- SPOTVIEW- 0V REF ---> 8,7 8 ---> 0V REF
VHREF <--- 2 10 <--- LIH- 9 ---> 0V REF
GND <--- 10 11 <--- RAD-EXP-ON- DR/T2
VREF <--- 3 12-15,17,48 --- 0V
GND <--- 11 28 ---> PREPACK- VH.REF <--- 2
HREF <--- 4 29 ---> EXPACK- V.REF <--- 3 NOT USE
GND <--- 12 31 ---> FLGNT- H.REF <--- 4
30 ---> PF-XRAY-TRG- 0V <--- 10,12
33 ---> FPOS- DR/T3 SYSTEM CABINET
PORT A 35 <--- AIC-SIG +15V <--- 12,11,9 PERIPHERAL I/F PWB
36 <--- GND( AIC-SIG ) TILT2- <--- 13 CNN ANC
FLREQ <--- 1,34
40 ---> ( SPARE ) TILT1- <--- 14
<--- 18, 2
41 ---> ( SPARE ) TILT0- <--- 15 50 <--- DR_SELECT
PREPREQ <--- 19, 3
42 <--- ( SPARE ) DIV0- <--- 2 17,18,19 <--- +15V (9,11,19)
EXPREQ <--- 20, 4
43 <--- ( SPARE ) DIV1- <--- 4 6 <--- PREPREQ-
PF_RATE0 <--- 21, 5 DR_SELECT <--- 5 8 <--- EXPREQ-
PF_RATE1 <--- 22, 6 45 ---> DR-OK-(ADR-ACTIVE-)
46 ---> INJECTOR- COMP- <--- 6 10 ---> PREPACK-
PF_MODE <--- 23, 7
47 ---> RPOS- SERIAL- <--- 8 12 ---> EXPACK-
SYSSTDBY <--- 24, 8
50 (+15V IN) ( SPARE ) <--- 7 16 <--- +24V
SPOTVLIH <--- 25, 9
I/F+15V ---> 10 20 <--- 0V
FL LIH <--- 26,10 DR/A3 DR-OK-(ADR-ACTIVE -) ---> 1 26 ---> FLGNT-
---> 27,11
1,2,14 <--- +15V OUT ( SPARE ) ---> 3 28 <--- FLREQ-
PREPACK ---> 28,12
EXPACK ---> 29,13 9 <--- DIV0- VD/T
---> 30,14 22 <--- DIV1-
10 <--- DIV2-(DR-SELECT-) +15V IN <--- 4
FLGNT ---> 31,15 SPOTVIEW- <--- 5
PF.TRIG P ---> 32,16 5 <--- ( SPARE ) NOT USE
18 <--- ( SPARE ) LIH- <--- 16 FOR
F_POS ---> 33,17
R_POS ---> 47,48 7 ---- (+15V IN) AIC-SIG <--- 1 THIS SYSTEM OPTICAL SYSTEM
3 ---> ( SPARE ) GND(AIC-SIG) <--- 8 CNN3 (AIC)
---> 49,50
16 ---> ( SPARE )
DR/OPT
PORT C VD/ADR1 MLT ---> NOT USE FOR
F_CODE1 <--- 9,2 <--- THIS SYSTEM
9 <--- ( SPARE )
F_CODE2 <--- 11,4 1,2 <--- +15V OUT DR/O
DR_SELECT <--- 12,5 6 <--- R.READY-
7 <--- R-XRAY-IN- +24V ---> 19,18,6
PORT D 3 ---- (+15V IN) F1-ON- ---> 20,7
8 ---> INJECTOR- F2-ON- ---> 21,8
READY <--- 1,6 5 ---> ( SPARE )
EXON <--- 2,7 4 ---> 0V
INJ ---> 8,4 DR/X
9,5 VD/ADR2 +5V ---> 9 X-RAY CONTROL KXO-80G
PORT B 1,2 <--- +15V OUT RXD <--- 2 CNN25
9 <--- H.REV- TXD ---> 3
H.REV <--- 1, 9 GND ---> 5
V.REV <--- 2,10 10 <--- V.REV-
(DOSE_1) <--- 3,11 6 <--- ( SPARE ) DR/X2
(DOSE_2) <--- 4,12 7 <--- ( SPARE )
15 ---- (+15V IN) +15V <--- 12, 5,4
ADR-ACTIVE ---> 5,13 AIC-SIG <--- 11,10,3 CNN21
6,14 3 ---> ( SPARE )
4 ---> ( SPARE ) GND(AIC-SIG) <--- 9, 2,1
5 <--- 0V +24V <--- 14, 7,6
PORT E 13 ---> ADR-ACTIVE- F1-ON- <--- 15
F2-ON- <--- 8
+/- ABC ---> 5 VD/ADR3
-/+ ABC ---> 1 VD/AEC CNN14
AGND-ISO ---> 3 5 ---> ABC OUT
3 ---> GND CONT +15V <--- 19
ABC ---> 3
AEC_VIDEO ---> 1
GND(AEC) ---> 2
AEC_VD- ---> 5 MTV I/F
AEC_CP ---> 6
AEC_HD- ---> 7
CONT_GND <--- 16,14
CONT-15V <--- 20
AEC GATE <--- 10
GATE RETURN <--- 11
( SPARE ) <--- 13
VD/VTR ( SPARE ) <--- 18
NOT USE BNC ( SPARE ) ---> 22
SYSTEM-STANDBY- <--- 12
MONITOR (IRM) R.READY- <--- 4
VIDEO OUT VD/CRT1 R-XRAY-IN- <--- 9
INJECTOR- ---> 17
BNC BNC 0V REF ---> 21
GND(FG) <--- 24,23
VD/CRT2 VD/CONT
NOT USE BNC +15VI <--- 9
H.REV- <--- 6
V.REV- <--- 8
PF-RATE0- <--- 10
PF-RATE1- <--- 11
PF-MODE- <--- 12
( READY- ) <--- 17
( F-ON- ) <--- 18
( SPARE ) <--- 2
( SPARE ) <--- 3
+15VO ---> 24
ADR-ACTIVE- ---> 22 SYSTEM CONNECTION DIAGRAM
PF-TRIGGER-PULSE- ---> 23 FOR
( SPARE ) ---> 14
( SPARE ) ---> 15 KXO-80G / DUA-450D / ADR-1000A

Figure Appendix B:-3: Main systems interconnection – configuration 3

System Interfaces B-5


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

PC PROCESSOR
P5

ADR I/F RACK


TABLE CONTROL BOX
SP2 MDX-8000A
POSI_INDX00 <--- 1
POSI_INDX01 <--- 2 ARBITRATION PWB
POSI_INDX02 <--- 3
POSI_INDX03 <--- 4
POSI_INDX04 <--- 5 SEE NOTE1 ADR4
POSI_INDX05 <--- 6
POSI_INDX06 <--- 7
POSI_INDX07 <--- 8
INDX_CHG <--- 10
ADR2

ANALOG I/O (IOB2)


VHREF <--- 2
GND <--- 10
VREF <--- 3 ADR1
GND <--- 11
HREF <--- 4
GND <--- 12

ADR3

PORT A
FLREQ <--- 1,34
<--- 18, 2
PREPREQ <--- 19, 3
EXPREQ <--- 20, 4
PF_RATE0 <--- 21, 5
PF_RATE1 <--- 22, 6
PF_MODE <--- 23, 7
SYSSTDBY <--- 24, 8
SPOTVLIH <--- 25, 9
FL LIH<--- 26,10
---> 27,11
PREPACK ---> 28,12
EXPACK ---> 29,13 ADRK-032A(AVDIF PWB) (SEE NOTE2)
---> 30,14
FLGNT ---> 31,15
PF.TRIG P ---> 32,16
F_POS ---> 33,17 VD/ADR1
R_POS ---> 47,48
---> 49,50 9 <--- ( SPARE )
1,2 <--- +15V OUT
6 <--- R.READY-
7 <--- R-XRAY-IN-
3 ---- (+15V IN)
PORT C
8 ---> INJECTOR-
F_CODE1 <--- 9,2 5 ---> ( SPARE )
F_CODE2 <--- 11,4 4 ---> 0V
DR_SELECT <--- 12,5
X-RAY CONTROL BOX
VD/AEC
VD/ADR2 KXO-80XM
CONT +15V <--- 19
PORT D 1,2 <--- +15V OUT SER1
ABC ---> 3
9 <--- H.REV-
READY <--- 1,6 AEC_VIDEO ---> 1
10 <--- V.REV-
EXON <--- 2,7 GND(AEC) ---> 2
6 <--- ( SPARE )
INJ ---> 8,4 AEC_VD- ---> 5
7 <--- ( SPARE )
9,5 AEC_CP ---> 6
15 ---- (+15V IN)
AEC_HD- ---> 7
3 ---> ( SPARE ) MTV
CONT_GND <--- 16,14
4 ---> ( SPARE )
PORT B 5 <--- 0V
CONT-15V <--- 20
AEC GATE <--- 10
H.REV <--- 1, 9 13 ---> ADR-ACTIVE-
GATE RETURN <--- 11
V.REV <--- 2,10
VD/ADR3 ( SPARE ) <--- 13
(DOSE_1) <--- 3,11
( SPARE ) <--- 18
(DOSE_2) <--- 4,12 5 ---> ABC OUT MTV I/F
( SPARE ) ---> 22
ADR-ACTIVE ---> 5,13 3 ---> GND SYSTEM-STANDBY- <--- 12 ADR/80XM
6,14
R.READY- <--- 4
R-XRAY-IN- <--- 9
INJECTOR- ---> 17
PORT E 0V REF ---> 21 CNN21
GND(FG) <--- 24,23
+/- ABC ---> 5
-/+ ABC ---> 1
AGND-ISO ---> 3

VD/CONT
VD/VTR +15VI <--- 9
H.REV- <--- 6 OPT/80XM
NOT USE BNC V.REV- <--- 8
MONITOR (IRM) PF-RATE0- <--- 10
PF-RATE1- <--- 11
VIDEO OUT VD/CRT1
PF-MODE- <--- 12 OPTICAL DEVICE
BNC BNC ( READY- ) <--- 17
( F-ON- ) <--- 18
( SPARE ) <--- 2 ND FILTER
VD/CRT2 ( SPARE ) <--- 3
+15VO ---> 24
NOT USE BNC
ADR-ACTIVE- ---> 22
PF-TRIGGER-PULSE- ---> 23
( SPARE ) ---> 14
( SPARE ) ---> 15

SYSTEM CONNECTION DIAGRAM


FOR
NOTE1:This connection is required for Bolus chasing DSA.
KXO-80XM / MDX-8000A / ADR-1000A
NOTE2:This PWB is installed into X-RAY CONTROL BOX.

Figure Appendix B:-4: Main systems interconnection – configuration 4

System Interfaces B-6


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

TABLE CU-BOX

BX BX BX BX
ADR-1000A 1 1 1 1
CABLES . . . .
I/O-2 PWB
. . . .
17 17 17 17
F.X-RAY
RC-I/O P3 . . . .
PORT-A A
TABLE 1 (T1) 34 34 34 34
I/F+24V 25 25
26 26 MTV MTV TO X-RAY
SPOT VIEW 9 9 13 13 CONTROL
IRIS SIG. 35 35 4 4
5 5
6 6
I/F0V 36 36 7 7
8 8
I/F0V
9 9
10 10
LIH 10 10 18 18
(HP34P) (HP34P)

AI AI (MOTHER BOARD) AI2


FLRE0- 34 34 18 18 2
RPOS 47 47 4 4
I/F+24V 1 1 3 3 I/F+24V
13 1
4
MPOSREF 48 48 5 5
FPOS 33 33 6 6
FLGNT 31 31 X X 19 19 3
OV 17 17 7 7
(24P) (24P) I/F0V (MOTHER BOARD)

BI BI (MOTHERBOARD)
11 11
EXPREO- 4 4 5 5
OVREF 12 12 29 29
PREPACK- 28 28 19 19 RY4 6
10 10
PREPEWO- 4 8
3 3 8 8

26 26 I/F+24V
+24VDC 19 19
+24VDC 20 20 27 27
EXPACK- 29 29 17 17
7 7
30 30
4 4
31 31
20 20
24 24
I/F0V 15 15 18 18
25 25
I/F0V 13 13 32 32
#26
(50P) (50P) (34P) (34P) I/F0V

IOB P1 ANALOG I/O ANALOG I/O EPS/AUX EPS/AUX (MOTHER BOARD)


TABLE 2 (T2)

}
VHREF 2 2 5 5 VHref
VREF 3 3 7.9 7.9 Vref
HREF 4 4 8 8 Href for ELECTRICAL SHUTTER
11 11 4 4
12 12 6 6
0V 10 10 #25
(F16P) (F16P)
(15P) (15P)
RC-I/O P4 PORT-C C OPT2 OPT2
TABLE 3 (T3)
+15V 9 9 1 1 I/F+15V
+15V 11 11 2 2 I/F+15V
+15V 12 12
FCODE1 2 2 17 17 FILM DIV.CODE 1
FCODE2 4 4 18 18 FILM DIV.CODE 2
FCODE3 5 5 19 19 FILM DIV.CODE 3
#32
(15P) (15P) (F20P) (F20P)

X-RAY CONT

RC-I/O P2 PORT-D D CNNB CNNB


GENERATOR (G)
+24v 1 1 19 19 +24V
+24V 2 2
GENARDY 6 6 4 4 R.READY
EX ON 7 7 9 9 RX
8 8 17 17 INJECTOR
4 4 21 21
#27
(9P) (9P) (24P) (24P)

Figure Appendix B:-5: Main systems interconnection – Systems without ADRK-006A or ADRK032A

System Interfaces B-7


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

Interconnection Cables List

Cable No. Cable Name & From To Connectors Length


Catalog No.
1 Main power PDU (Terminal Main Power Power with 15m
cable Block) Ground
81AP100155
5, 6, 28, PDU (Rack) PDU (Terminal Monitors, Power with 5-6:20m
29, 38 Block) Video Ground
Switcher, etc.
2 PDU GND PDU (Rack) Room GND Bind Post 15m
81AP100302 GND Stab
4 TV Camera DC PDU (Terminal Camera 3DIN 20m
Power Block)
81AP101270
7 Out power video PDU (Terminal Video Power 20m
switched cable Block) switcher
82AP100153
8 ON/OFF PDU ON/OFF Built in 30 m
switcher switcher
9 IRIS control IRIS IOB Dtype 15 pin 20m
cable
81AP101177
11 Out power MPU PDU (Terminal MPU power Power with 20m
81AP100151 Block) Ground
10 Fiber Optic MPU (NPRCB) PDU Optic 20m
(Dual)
WA81102001
12 keypad 2 Keypad 1 In Room Straight header 30m
81AP100185 Keypad 2 10 pin
13 Keypad 1 MPU (PC) Keypad 1 Dtype/Straight 5m
81AP101189 Header 10 pin
9pin & 25 pin
16 RGB Monitor W.S. Monitor MPU BNC/Dtype 2m
81AP100220
17 WS Power MPU WS Monitor Power 2m
81AP100180
18 DEEB Video MPU (DEEB) Video BNC 30m
Switcher Switcher
81AP100222
19 NPRCB to Cam MPU (NPRCB) Cam 68 pin SCSI 30m
data
81AP101172
20 Cam to Video Camera Video BNC 40m
Switcher Video Switcher
81AP100223

System Interfaces B-8


CMT Medical Technologies Ltd. ADR-1000A Maintenance Manual
REV 2.1

Cable No. Cable Name & From To Connectors Length


Catalog No.
21 Video Switcher Video Switcher IRM BNC 20m
to Monitor
Video
81AP100224
22 Console monitor IRM Console BNC 30m
25 X-Ray PDU X-Ray Room Dtype 15 pin 15m
26 Generator and Control Dtype 50 pin
27 Table Interface Dtype 9 pin
32 (Supplied by Dtype 15 pin
40 (Bolus) Toshiba) Dtype 15 pin
30 Scan Converter MPU (DEEB) Scan SBC Dtype Sub TBD
Video Converter
31 Video Switcher Video Switcher PDU Audio/Mono 20m
Remote Control
33 VCR Remote PDU (RC-I/O) VCR Audio/Mono TBD
Control
34 Camera GND PDU Camera Lug 20m
81AP101321 (Terminal Enclosure
Block)
36 MPU GND PDU MPU Lug 20m
81AP100322 (Terminal
Block)
39 D2 video RTEE D2 monitor BNC 30m
Diagnostic set
-------- -------- ---------- ---------- --------
8SERV30003
Table 1: Cable List

NOTE:
Some of the listed cables are optional and/or may not be supplied by CMT.
For your specific cable list please refer to the system packing-list.