Dual Wavelength Laser For Cosmetic Gynecology
Dual Wavelength Laser For Cosmetic Gynecology
Dual Wavelength Laser For Cosmetic Gynecology
Dual Wavelength
15 watts/1470nm+635nm
www.photoniccs.com
We Offer Diode Lasers with
a 980 1470 _
. NA
102 =
Ew 4 KY _| 15w/1470nm+635nm
Ee Want wavelength for Proctology,
Bed ee Varicose vein,
Cosmetic Gynecology,
Wound Management
T T T T T
400 600 800 1000 1200 1400
Water
Hemoglobin
Accessories
- ——
Radial Fiber Conical Fiber Permanent Fiber Disposable Tips Proctology Handpiece
(Optional) (Optional) (Optional) ( Optional )
Hemorrhoids
Fistula
Laser energy is delivered by optical fiber into the anal fistula tract and is used
to thermally ablate and
close of the abnormal pathway. The laser energy induces destruction of the fistula
epithelium and
simultaneous obliteration of the remaining fistula tract by shrinkage effect. The
epithelialized tissue is
being destroyed in a controlled way and the fistula tract collapses to a very high
degree. This also
supports and accelerates the healing process. Advantage of using diode laser using
radial fiber
compared to conventional surgery is, it gives good control to operator, also allows
use in convoluted
tract. Surgical procedure can be executed in few minutes.
Fissure
Pilonidal Sinus
Thanks to light tissue interaction mainly thermal effects occur, the tissue is
heated and the walls of the
vein shrink, because of alteration of endothelium and contraction of collagen.
There are two possibilities of performing the treatment: with pulsed and
continuous-wave laser
operation. Using the pulsed operation also the fibre is withdrawn step by step. A
better choice is to use
continuous-wave laser and to withdraw the fibre also continuously, what provides
more homogenous
illumination of the vein, less tissue damage outside the vein and better results.
The therapy is just a beginning of the occlusion process. After the treatment the
veins are shrinking
for several days or weeks. That's why in the long-period observation, very good
results are obtained.
Laser Treatment for
Cosmetic Gynecology
A new and innovative technique combines the action of the infrared laser and the
Laser handpiece in order to accelerate the
production and the remodeling of mucosa's collagen.
Age and muscular stress often cause an atrophic process within the vagina. If not
adequately treated, this results in dryness, sexual
difficulties, itching, burning, tissue laxity and urinary incontinence. The main
cause of this is the loss of tone of the vaginal mucosa.
The Laser treatment targets the vaginal mucosa. The wavelength (15w/1470nm+635nm),
combined with the controlled, radial
emission of the Laser hand piece, has a bio-modulating effect that stimulates
Neocollagenesis and regenerates the epithelium and
the connective tissue. This action rejuvenates the mucosa by restoring firmness,
flexibility and hydration; therefore, considerably
reducing symptoms, that are usually attributes of menopause. Laser also has a
positive effect on urinary incontinence, in many cases
restoring the normal functions.
The main advantage of using a diode laser is that the laser can penetrate deeper,
targeting the mucosa, without causing an ablative
thermal injury.
The design of handpiece and the circular emission are the uniqueness of the Laser.
They allow for a painless treatment. The
combination also ensures that the laser evenly targets all tissue on the inner
walls of the vagina.
Although the software is easy to use with suggested settings, the surgeon can also
manually alter the settings according to the
requirement of the surgery. Additional handpieces are available for internal and
external vulvar treatments, as well as aesthetic
microsurgery.
© Vaginal Tightening
Before After
Increased Collagen © Effective and painle
Improved Muscle Tone © Non-invasive
Improved Sensation
Enhanced Orgasm
0000000
Laser treatment for
Liposuction
Laser Technology
The unique radial and bare emitting fiber of the device helps in wider and
even-heat emission distribution, with precise temperature control capabilities.
The results are improved skin tightening, reduced procedure time, high-fat
viability for successful grafting and superior clinical results.
Optimal Wavelength
Liposuction Cannula
Liposuction cannula helps break up fatty tissue so that it can be easily suctioned
and removed from the
body. Small precise oscillations allow surgeons to target specific areas safely
without damaging the
surrounding tissue. This technique is especially useful for treating areas with
dense and fibrous adipose
tissue.
Cannula combined with simultaneous lasing and suction allows surgeons to remove fat
more quickly with
ease and less manual force. This results in less bruising and shorter recovery time
and more comfortable
experience for both surgeon and patient.
Before
PLDD procedures are performed under local anaesthesia. An optical fibre is inserted
into a
working cannula under fluoroscopic guidance. Using fluoroscopy alongside a contrast
medium,
the cannulas position and the condition of the disc bulge can be confirmed. The
laser will then
initiate decompression and lower intradiscal pressure.
Main indications
© Bulging disc
Advantages of PLDD
No General Anaesthesia
No Arthrodesis (fusion)
Minimally Invasive
AR PHOTONICCS
fy PHOTONICCS
Therapy for
Wound Healing
almost twice as fast and are less likely to develop complications. Furthermore, the
use of laser light reduces pain, swelling,
inflammation and exudate that accompanies chronic wounds.
Discolourations
>)
o pills EU ol elses melas © Time saving for the patient and the doctor
© Promotion of nseUing © Effective treatment with fewer visits
© Venous leg ulcer © Noticeably higher revenues for the practice
2) Digit tee! eymeleme 6 Working with the best wavelengths
dues © No need for hospitalization in the postoperative period
© Cuts
° >)
>)
CASE STUDY
© Faster Healing
© Reduced Pain and Inflammation
© Minimized Scarring
Pyroronces,
we OTONICCS
PHOTONICCSy,
Specification
Laser type Diode, Semiconductor
Wavelength 1470nm+635nm
Max Power 15 watts
Aiming beam
Operation Mode
Continuous or pulsed
Pulsed Time
0.05ms~1000ms
Beam Delivery
SMA205 connector
Footswitch
Controller Microprocessor
Display 10.1” IPS with touch panel Medical approved
Cooling Internal, air and thermoelectric cooling
IIB
Laser safety Class 4
Electric Safety Class | type B
Housing Protection Degree Ip20b
Footswitch Protection Degree IPX6
PHOTONICCS y