L Series Details 26 COS 111213-3050597
L Series Details 26 COS 111213-3050597
L Series Details 26 COS 111213-3050597
P ROD UC T WE BP A GE
Typical Applications
∙ Construction ∙ Agriculture ∙ On-Highway
2.
Tech Specs
Electrical Environmental
Contact Rating 4VA @ 24VDC (MAX) resistive Sealing IP67, for above-panel
15 amps, 125VAC components of actual switch only
10 amps, 250VAC
20 amps, 4-14VDC Corrosion Mixed Flowing Gas MFG Class III per ASTM
15 amps, 15-28VDC B-827 & B-845, Method H, with 3 years
exposure.
Dielectric Strength 1250 Volts RMS between pole to
pole 3750 Volts RMS between live Operating Temp -40°C to + 85°C
parts and accessible surfaces
Vibration 1 Per Mil-Std 202F, Method 204D
Insulation Resistance 50 Megohms Test Condition A 0.06 DA or
10G’s 10-500 Hz. Tested with
Initial Contact Resistance 10 milliohms max. @ 4 VDC VCH connector. Test criteria - No
loss of circuit during test and pre
Life Up to 100,000 cycles maintained,
and post test contact resistance.
50,000 cycles momentary circuit
and load dependent Vibration 2 Resonance search
24-50 Hz 0.40 DA
Contacts 90/10 silver-nickel, silver
50-2000 ±10 G’s peak
tin-oxide, gold
Results Horizontal Axis 3-5 G’s max.
Terminals Brass or copper/silver plate Random
3/16” (4.76mm) & 1/4” (6.3mm) 24 Hz 0.06 PSD-Gsq/Hz
Quick Connect terminations 60 Hz 0.50
standard. 100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10µ chatter.
Physical Shock Per Mil-Std 202F, Method 213B,
Test Condition K @ 30G’s. Tested with VCH
Lighted Incandescent - rated 10,000
connector. Test criteria - No loss of circuit
hours
LED - rated 100,000 hours 1/2 life during test, pre, and post test contact
(LED is internally ballasted for resistance.
voltages to 24 VDC)
Salt Spray Per Mil-Std 202F, Method 101D,
Seals Rocker, base & bracket are Test Condition A, 48 Hrs.
sealed.
Thermal Shock Per Mil-Std 202F, Method 107F,
Base Nylon 66 GF rated to 85°C with a Test Condition A, -55°C to 85°C.
flammability rating of 94V0. Test criteria - pre and post test
contact resistance.
Actuator Basic actuator structure molded
of thermoplastic polycarbonate Moisture Per Mil-Std 202F, Method 106F,
with a hard Nylon 66 Resistance Test Criteria - pre and post test
thermoplastic surface overlay. contact resistance.
Locks Acetal
MOUNTING HOLE
Panel Thickness Range
Actuator Travel (Angular Displacement) Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
2 Position 26° Recommended: .030, .062, .093, .125 and .156
3. *Manufacturer reserves the right to change product specification without prior notice.
Ordering Scheme Rocker
Sample
Part Number L 11 E 3 C H N 1 - 3 A A 45 - 1 48
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13 14
4. TERMINATION 2,3
Sample
Part Number L 11 D 1 S W C J - P M H 00 - 0
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13
1. SERIES 7. LAMP
L No lamp 0
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* Red Amber Green
2. CIRCUIT 5 2VDC A L F
6VDC B M G
Terminal Orientation ( ) - momentary 12VDC C N H
SP - single pole - uses terminals 1, 2 & 4. 24VDC D P J
DP - double pole uses terminals 5, 6 & 8. * Consult factory for “daylight bright”, blue/green and white LED options.
Terminals 9, 10 & 11 for lamp circuit only. Typical current draw for LED is 20ma.
8. BRACKET COLOR 1
Position: 1 2 3
SP DP 2 & 4, 6 & 8 Connected Terminals 1 & 2, 5 & 6 J Black
11 21 ON NONE OFF
14 24 ON NONE ON
16 26 ON OFF ON 9. ACTUATOR STYLE AND COLOR 1
17 27 ON OFF (ON)
18 28 (ON) OFF (ON) Black Red
CIRCUITS WITH JUMPER TERMINALS Locking Rocker P R
30 2 (2,4&5), (1,6&8) OFF, OFF (1,2&8), (4,5&6)
31 2 1, 2 & 5 2, 3 & 7 2, 4 & 8
PROGRESSIVE CIRCUITS 10 & 11. LENS STYLE AND COLOR
51 3&4 2, 3 1&2
52 3&4 2, 3 OFF Lens color for LEDs must be clear, white, or match color of LED.
53 (3 & 4) 2, 3 1&2 0 - No Actuator Z - No Lens
54 (3 & 4) 2, 3 (OFF) Clear White Amber Green Red Blue
55 (3 & 4) 2, 3 (1 & 2) 1 - B G M T Large Transparent
56 (3 & 4) 2, 3 (OFF) - 7 C H N U Large Translucent
57 3&4 2, 3 (OFF) 3 - D J P V Bar Transparent
58 2&4 2, 3 1&2 - 9 E K R W Bar Translucent
61 3 & 4, 7 & 8 2 & 3, 6 & 7 1 & 2, 5 & 6
62 3 & 4, 7 & 8 2 & 3, 6 & 7 OFF, OFF
63 (3 & 4), (7 & 8) 2 & 3, 6 & 7 1 & 2, 5 & 6
64 (3 & 4), (7 & 8) 2 & 3, 6 & 7 OFF, OFF 11. LOCK FUNCTION AND COLOR
65 (3 & 4), (7 & 8) 2 & 3, 6 & 7 (1 & 2), (5 & 6) Locking Position
66 (3 & 4), (7 & 8) 2 & 3, 6 & 7 (OFF, OFF) Up Down Up & Down Center 3 Lock Color
67 3 & 4, 7 & 8 2 & 3, 6 & 7 (OFF, OFF) A H R 1 Match Actuator
68 2 & 4, 7 & 8 2 & 4, OFF OFF, OFF B J S 2 Black
69 2 & 4, 1, 7 & 8 2 & 4, OFF OFF, OFF C K T 3 White
70 (2 & 4), (7 & 8) 2 & 4, 5 & 7 (1 & 2), (5 & 7) D L V 4 Red
71 (2&4), (7 & 8) 2 & 4, 5 & 7 1 & 2, 5 & 7 E M W 5 Safety Orange
72 2 & 4, 7 & 8 2 & 4, 5 & 7 1 & 2, 5 & 7
73 (2 & 4), (7 & 8) 2 & 4, OFF OFF, OFF
80 2 & 4, 6 & 8 2 & 4, OFF OFF, 5 & 6
12. LASER ETCHED, LENS OR BODY LEGEND
00 No legend
For standard legends, see “Standard Legend Codes” page.
3. RATING 2 For additional legends, please consult factory
1 .4VA @ 28VDC Resistive E 15A 12V
B 15A 24V G 20A 6V 13. LEGEND ORIENTATION
C 20A 18V H 20A 3V
D 20A 12V 0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1 - vertical, lamp 1 on top
2 Orientation 2 - horizontal, lamp 1 on right
3 Orientation 3 - vertical, lamp 1 on bottom
4. TERMINATION 4
4 Orientation 4 - vertical, lamp 1 on left
1 .250 (6.4mm) TAB (QC)
P
3 .187 (4.7mm) TAB (QC)
Do not use silicone based lubricants to reduce terminal insertion forces during P P
connector assembly, as it is detrimental to function and performance.
P
5. ILLUMINATION 1 2 3 4
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12
end of switch. Positive (+) and negative (-) symbols apply to LED lamps only.
Lamps Illumination Type Lamp Wired to Terminals Notes: Consult factory to verify horsepower rating for your particular circuit choice.
S None 1 Custom colors are available. Consult factory.
B #2 Independent 12+ 11- 2 Additional lamp circuits available. Consult factory.
3 Available only with 3 position circuits.
4 Termination 3 only available with ratings 1, B and E.
5 Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H.
6. LOCK
W Lock above terminals 10 & 9.
Configure Complete Part Number > Browse Standard Parts >
5.
Ordering Scheme Window Lift
Sample
Part Number L 70 D 1 K 0 C W - W Z A RY - 3 00
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4
Configure Complete Part Number > Browse Standard Parts >
14. LEGEND #2 4
00 No legend
For standard legends, see “Standard Legend Codes” page.
For additional legends, please consult factory
6. COS-0119 Rev:E
*Manufacturer reserves the right to change product specification without prior notice.
Dimensional Specs
inches [millimeters]
L-SERIES L-SERIES
SHOWN WITH LASER ETCHED SHOWN WITH ROCKER GUARD
ACTUATOR
1.970
[50.04]
1.020
[25.91]
.400 .435
[10.16] [10.16]
1.450
[36.83]
.855
[21.72]
1.970
1.970 [50.04]
[50.04]
1.020
[25.91] 1.020
[25.91]
.453 .760
[11.51] [19.3]
.400
[10.16]
1.450
12 4 3 2 1 10 [36.83]
2.380
[60.45]
12 4 3 2 1 10 .855
[21.72]
Connector L-SERIES
CONNECTOR Hole Plug L-SERIES
HOLE PLUG
LC1-01 BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES) LH1 REMOVABLE HOLE PLUG
1.970 WITH NON-SERRATED WINGS
LC2-01 BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES)
LC3-01 BLACK .250 TAB CONNECTOR (AMP ONLY) [50.04] LH2 HOLE PLUG WITH
SERRATED WINGS
1.020
[25.91]
.500
[12.70]
1.325
.920 [33.66] .300
[23.37] [7.62]
1.710 .855
.790
[43.43] [21.72]
[20.07]
7.
Dimensional Specs
inches [millimeters]
+.008
-.000 +.008
.984 -.000
2.020
[25.00]
[51.31]
R. 093 MAX TYP R. 093 MAX TYP
MOUNTING PANEL
+.008 TEST FOR ADDITIONAL UNITS< ADD 1.03 [26.2] PER UNIT.
TEST -.000 +.008
CUT 1.900 CUT -.000 FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE
HOLE IN HOLE IN 1.900 SECTION. AVAILABLE IN PANEL THICKNESSES LISTED
[48.26]
ACTUAL ACTUAL [48.26] BELOW> CONSULT FACTORY
MATERIAL MATERIAL DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF
CENTER BEZELS (LMM) X 1.034 [26.26mm]
MOUNTING PANEL THICKNESS
LMS MOUNTING PANEL
.062 .093 .125 .156
MOUNTING PANEL OPENING
[1.57] [2.36] [3.17] [3.96]
HOLE (2) UNITS
1.700 1.030
[43.18] [26.16]
1.030 .670
[26.16] [17.02]
2.300 2.300
[58.42] [58.42]
3.400 4.430
[86.36] [112.52]
LM3 MOUNTING PANEL LM4 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 x 3.06 [48.3mm x 77.7mm] PANEL OPENING SIZE: 1.90 x 4.09 [48.3mm x 103.9mm]
1.030
[26.16]
.670
[17.02]
2.300
[58.42]
6.490
[164.85]
LM6 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 x 6.15 [48.3mm x 156.2mm]
8.
Circuit Diagrams
11 22 51
2 2 6 2 4
4 4 5 3
12 23 52
2 2 6 2 4
4 1 4 5 8 1 3
13 24 53
2 2 6 2 4
1 4 1 4 5 8 3
14 25 54
2 2 6 2 4
1 4 1 4 5 8 1 3
15 26 55
2 2 6 2 4
1 4 1 4 5 8 3
16 27 56
2 2 6 2 4
1 4 1 4 5 8 3
17 28 57
2 2 6 2 4
1 4 1 4 5 8 1 3 4
18 30 58
2 2 6 2
4 8 1 3 4 5 7 8 1 3 5 7
21 31 61
2 6 2 2 4 6 8
9.
Circuit Diagrams
CIRCUIT CIRCUIT
CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM
3 7 1 4 5 8
62 71
2 4 6 8 2 7
1 3 5 7 1 4 5 8
63 72
2 4 6 8 2 7
3 7 4 8
64 73
2 4 6 8 2 7
1 3 5 7 4 5 8
65 80
2 4 6 8 2 6
3 7 4 5 8 1
66 81
2 4 6 8 2 6
3 7 1 4 5 8
67 82
2 4 6 8 3 6
4 8 1 2 3 4 7 8
68 A2
INTERNAL
CONNECTION
2 7 6
4 8 1 1 4 7 8
69 A3
INTERNAL
CONNECTION
2 7 2 6
1 4 5 8
70
2 7
10.
Lamp Circuit Diagrams
LAMP CIRCUIT LAMP CIRCUIT
CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM
-9 -9 +1 +4
A J
1 1 2
+10
-11 -12
B 1 INTERNAL
CONNECTION 2
2
+12 +10
-9 -12
C 2 1
INTERNAL
CONNECTION
1 2
+10
+10 +12
(–)9
-9 +4
D K 1
1
(+)10
-9 +4
E
LEGEND
1 2
SYMBOL DEFINITION
+10
-9 +8 TERMINAL LOCATION
LAMP LOCATION
F 1 2 MAINTAINED CIRCUIT
MOMENTARY CIRCUIT
2 POSITION CONNECTION
G 1 2
P3 P1
2 POSITION
+10
-9
P2 P1
P3
3 POSITION
H 1 2
+10
11.
Standard Legend Codes
YK UA UB US UV UW UX UY MP MR PX MS MT
VU MW NZ NX NY YM VW PS PW PZ WG WM RN
RP YG TX VD VE VF VG SH SM SN SP SR SY
WY WZ UH UJ PD PE PF VC VJ UF UG MU TN
NS PB SE VZ YE NN RW PU WA YN UE NM RJ
NR YD TL VR SL VA UC VN PK VY UZ RH NU
NV RB RC RK RL MZ RG WS WT UD UR WD TY
WATER
PUMP
PA UK WR UU UT YR PM VV WB TB TC TD TE
MY PV TA TZ WC PT PN PH RA TU TT YL SK
VS UL UM WK TS VT WL VP YJ PJ RY UP NW
NP RE RF PP PR TV PC YT YU PL WJ MV RR
TK RT SZ VX WF WH PG SJ YA YB RM TM RD
RS UN TP TR NT MX YC TW TJ YF TH TF TG
YS YH SX RZ YP WN WP WW WX SA SB SC SD
ST SU WU WV SV SW VB VH VK VL VM WE SF
SG SS RU RV RX
CLA-0146 Rev: A
12. ISO compliant symbols. Consult factory for custom legends.
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors
or visit www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and
electronic switches and assemblies, circuit breakers, electronic controls, power
distribution units, and multiplexed power distribution systems. With six ISO9001 and
IATF16949 registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than
manufacture electrical components, they engineer powerful solutions! To learn more
about Carling please visit www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications.
Authorized Distributor
Carling Technologies: