TMP 102
TMP 102
TMP 102
TMP102
ZHCSIX4I – AUGUST 2007 – REVISED JUNE 2024
TMP102
Two-Wire 1 6
Host Controller SCL SDA Config.
3 4
ALERT OSC and Temp. ADD0
2 5 Register
GND V+
3 4
ALERT ADD0
方框图
简化原理图
Table of Contents
1 特性................................................................................... 1 6.5 Programming............................................................ 16
2 应用................................................................................... 1 7 Application and Implementation.................................. 20
3 说明................................................................................... 1 7.1 Application Information............................................. 20
4 Pin Configuration and Functions...................................3 7.2 Typical Application.................................................... 20
5 Specifications.................................................................. 4 7.3 Power Supply Recommendations.............................22
5.1 Absolute Maximum Ratings........................................ 4 7.4 Layout....................................................................... 22
5.2 ESD Ratings............................................................... 4 8 Device and Documentation Support............................23
5.3 Recommended Operating Conditions.........................4 8.1 Documentation Support............................................ 23
5.4 Thermal Information....................................................4 8.2 接收文档更新通知..................................................... 23
5.5 Electrical Characteristics.............................................5 8.3 支持资源....................................................................23
5.6 Timing Requirements.................................................. 6 8.4 Trademarks............................................................... 23
5.7 Typical Characteristics................................................ 7 8.5 静电放电警告............................................................ 23
6 Detailed Description........................................................8 8.6 术语表....................................................................... 23
6.1 Overview..................................................................... 8 9 Revision History............................................................ 23
6.2 Functional Block Diagram........................................... 8 10 Mechanical, Packaging, and Orderable
6.3 Feature Description.....................................................8 Information.................................................................... 25
6.4 Device Functional Modes..........................................14
SCL 1 6 SDA
CBZ
GND 2 5 V+
ALERT 3 4 ADD0
5 Specifications
5.1 Absolute Maximum Ratings
Over operating free-air temperature range (unless otherwise noted)(1)
MIN MAX UNIT
Supply voltage 4 V
Voltage at SCL, SDA and ADD0(2) –0.5 4 V
((V+) + 0.3)
Voltage at ALERT V
and ≤ 4
Operating temperature –55 150 °C
Junction temperature 150 °C
Storage temperature, Tstg –60 150 °C
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply
functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If
used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully
functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) Input voltage rating applies to all TMP102 input voltages.
VALUE UNIT
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000
V(ESD) Electrostatic discharge Charged-device model (CDM), per JEDEC specification JESD22- V
±1000
C101(2)
(1) Level listed above is the passing level per ANSI, ESDA, and JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows
safe manufacturing with a standard ESD control process.
(2) Level listed above is the passing level per EIA-JEDEC JESD22-C101. JEDEC document JEP157 states that 250-V CDM allows safe
manufacturing with a standard ESD control process
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
note.
8.5 3,000
1.4V Supply 1.4V Supply
8 3.6V Supply 3.6V Supply
2,500
7.5
7 2,000
ISD (nA)
6.5
IQ (A)
1,500
6
5.5 1,000
5
500
4.5
4 0
-60 -40 -20 0 20 40 60 80 100 120 140 160 -60 -40 -20 0 20 40 60 80 100 120 140 160
Te mperature (C) Te mperature (C)
12 35.0
11 30.0
IQ (A)
10 25.0
9 20.0
8 15.0
7 10.0
6 5.0
5 0.0
-60 -40 -20 0 20 40 60 80 100 120 140 160 1x103 1x104 1x105 1x106 1x107
Te mperature (C) Bus Frequency (Hz)
50
0.4
Population
0.2 40
0
30
-0.2
20
-0.4
-0.6 10
-0.8
0
-0.35
-0.25
-0.15
-0.05
0.05
0.15
0.25
0.35
-0.3
-0.2
-0.1
0.1
0.2
0.3
0.4
0
-1
-60 -40 -20 0 20 40 60 80 100 120 140 D001
Temperature (qC) D002 Temperature Error (qC)
6 Detailed Description
6.1 Overview
The TMP102 device is a digital temperature sensor that is designed for thermal-management and thermal-
protection applications. The TMP102 device is two-wire, SMBus and I2C interface-compatible. The device is
specified over an operating temperature range of –40°C to 125°C. See Functional Block Diagram for a block
diagram of the TMP102 device.
The TMP102 device is a temperature sensor. Thermal paths run through the package leads as well as the plastic
package. The package leads provide the primary thermal path because of the lower thermal resistance of the
metal.
An alternative version of the TMP102 device is available. The TMP112 device has highest accuracy, the same
micro-package, and is pin-to-pin compatible.
表 6-1. Advantages of TMP112 versus TMP102
SUPPLY SUPPLY SPECIFIED
COMPATIBLE SUPPLY LOCAL SENSOR ACCURACY
DEVICE PACKAGE VOLTAGE VOLTAGE RESOLUTION CALIBRATION
INTERFACES CURRENT (MAX)
(MIN) (MAX) DRIFT SLOPE
I2C SOT563 12 bit 0.5°C: (0°C to 65°C)
TMP112 7.5 µA 1.4 V 3.6 V Yes
SMBus 1.2 × 1.6 × 0.6 0.0625°C 1°C: (-40°C to 125°C)
I2C SOT563 12 bit 2°C: (25°C to 85°C)
TMP102 7.5 µA 1.4 V 3.6 V No
SMBus 1.2 × 1.6 × 0.6 0.0625°C 3°C: (-40°C to 125°C)
Diode
1 Control 6
SCL Temp. SDA
Logic
Sensor
DS
2 Serial 5
GND A/D V+
Interface
Converter
Config.
3 4
ALERT OSC and Temp. ADD0
Register
(1) The resolution for the Temp ADC in Internal Temperature mode is 0.0625°C/count.
表 6-2 does not list all temperatures. Use the following rules to obtain the digital data format for a given
temperature or the temperature for a given digital data format.
To convert positive temperatures to a digital data format:
1. Divide the temperature by the resolution
2. Convert the result to binary code with a 12-bit, left-justified format, and MSB = 0 to denote a positive sign.
Example: (50°C) / (0.0625°C / LSB) = 800 = 320h = 0011 0010 0000
To convert a positive digital data format to temperature:
1. Convert the 12-bit, left-justified binary temperature result, with the MSB = 0 to denote a positive sign, to a
decimal number.
2. Multiply the decimal number by the resolution to obtain the positive temperature.
Example: 0011 0010 0000 = 320h = 800 × (0.0625°C / LSB) = 50°C
To convert negative temperatures to a digital data format:
1. Divide the absolute value of the temperature by the resolution, and convert the result to binary code with a
12-bit, left-justified format.
2. Generate the twos complement of the result by complementing the binary number and adding one. Denote a
negative number with MSB = 1.
Example: (|–25°C|) / (0.0625°C / LSB) = 400 = 190h = 0001 1001 0000
Two's complement format: 1110 0110 1111 + 1 = 1110 0111 0000
To convert a negative digital data format to temperature:
1. Generate the twos compliment of the 12-bit, left-justified binary number of the temperature result (with MSB
= 1, denoting negative temperature result) by complementing the binary number and adding one. This
represents the binary number of the absolute value of the temperature.
2. Convert to decimal number and multiply by the resolution to get the absolute temperature, then multiply by
–1 for the negative sign.
Example: 1110 0111 0000 has twos compliment of 0001 1001 0000 = 0001 1000 1111 + 1
Convert to temperature: 0001 1001 0000 = 190h = 400; 400 × (0.0625°C / LSB) = 25°C = (|–25°C|); (|–
25°C|) × (–1) = –25°C
If multiple devices on the bus respond to the SMBus alert command, arbitration during the target address portion
of the SMBus alert command determines which device clears the ALERT status. The device with the lowest two-
wire address wins the arbitration. If the TMP102 device wins the arbitration, the ALERT pin inactivates at the
completion of the SMBus alert command. If the TMP102 device loses the arbitration, the ALERT pin remains
active.
6.3.8 General Call
The TMP102 device responds to a two-wire general call address (000 0000) if the eighth bit is 0. The device
acknowledges the general call address and responds to commands in the second byte. If the second byte is
0000 0110, the TMP102 device internal registers are reset to power-up values. The TMP102 device does not
support the general address acquire command.
6.3.9 High-Speed (HS) Mode
For the two-wire bus to operate at frequencies above 400 kHz, the controller device must issue an HS-Mode
controller code (0000 1xxx) as the first byte after a START condition to switch the bus to high-speed operation.
The TMP102 device does not acknowledge this byte, but switches the input filters on SDA and SCL and the
output filters on SDA to operate in HS-mode, allowing transfers of up to 2.85 MHz. After sending the HS-Mode
controller code and NACK bit, user must send a repeated start before sending the target address. The bus
continues to operate in HS-Mode until a STOP condition occurs on the bus. Upon receiving the STOP condition,
the TMP102 device switches the input and output filters back to fast-mode operation.
6.3.10 Timeout Function
The TMP102 device resets the serial interface if SCL is held low for 30 ms (typ) between a start and stop
condition. The TMP102 device releases the SDA line if the SCL pin is pulled low and waits for a start condition
from the host controller. To avoid activating the time-out function, maintaining a communication speed of at least
1 kHz for SCL operating frequency is necessary..
6.3.11 Timing Diagrams
The TMP102 device is two-wire, SMBus, and I2C-interface compatible. 图 6-1, 图 6-2, 图 6-3, and 图 6-4 list the
various operations on the TMP102 device. Parameters for 图 6-1 are defined in the Timing Requirements table.
The bus definitions are defined as follows:
Acknowledge Each receiving device, when addressed, is obliged to generate an acknowledge bit. A
device that acknowledges must pull down the SDA line during the acknowledge clock pulse
in such a way that the SDA line is stable low during the high period of the Acknowledge
clock pulse. Setup and hold times must be taken into account. On a controller receive, the
termination of the data transfer can be signaled by the controller generating a not-
acknowledge (1) on the last byte that has been transmitted by the target.
Bus Idle Both SDA and SCL lines remain high.
Data Transfer The number of data bytes transferred between a START and a STOP condition is not
limited and is determined by the controller device. The TMP102 device can also be used for
single byte updates. To update only the MS byte, terminate the communication by issuing a
START or STOP communication on the bus.
Start Data A change in the state of the SDA line, from high to low, when the SCL line is high, defines a
Transfer START condition. Each data transfer is initiated with a START condition.
Stop Data A change in the state of the SDA line from low to high when the SCL line is high defines a
Transfer STOP condition. Each data transfer is terminated with a repeated START or STOP
condition.
t(LOW)
tFC t(HDSTA)
tRC
SCL
SDA
t(BUF)
tRD tFD
P S S P
SCL …
SDA 1 0 0 1 0
(1)
A1
(1)
A0 R/W 0 0 0 0 0 0 P1 P0 …
Start By ACK By ACK By
Host Device Device
Frame 1 Two Wire Device Address Byte Frame 2 Pointer Register Byte
1 9 1 9
SCL
(Continued)
SDA
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
(Continued)
ACK By ACK By Stop By
Device Device Host
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
1 9 1 9
SCL …
SDA 1 0 0 1 0 A1
(1)
A0
(1)
R /W 0 0 0 0 0 0 P1 P0 …
Start By ACK By ACK By Stop By
Host Device Device Host
Frame 1 Two-Wire Device Address Byte Frame 2 Pointer Register Byte
1 9 1 9
SCL
(Continued)
…
SDA
(Continued)
1 0 0 1 0 A1
(1)
A0
(1)
R/W D7 D6 D5 D4 D3 D2 D1 D0 …
Start By ACK By From ACK By
Host Device Device Host (2)
Frame 3 Two-Wire Device Address Byte Frame 4 Data Byte 1 Read Register
1 9
SCL
(Continued)
SDA
D7 D6 D5 D4 D3 D2 D1 D0
(Continued)
From ACK By Stop By
(3)
Device Host Host
Frame 5 Data Byte 2 Read Register
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
(2) Host should leave SDA high to terminate a single-byte read operation.
(3) Host should leave SDA high to terminate a two-byte read operation.
ALERT
1 9 1 9
SCL
(1) (1)
SDA 0 0 0 1 1 0 0 R/W 1 0 0 1 A1 A0 Status
Frame 1 SMBus ALERT Response Address Byte Frame 2 Device Address Byte
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
After power-up or general-call reset, the TMP102 immediately starts a conversion, as shown in 图 6-5. The first
result is available after 10 ms (typical). The active quiescent current during conversion is 55 μA (typical at
+27°C). The quiescent current during delay is 2.6 μA (typical at +27°C).
Delay(1)
10ms
10ms
Startup Start of
Conversion
A. Delay is set by CR1 and CR0.
Pointer
Register
Temperature
Register
SCL
Configuration
Register
I/O
Control
Interface
TLOW
Register
SDA
THIGH
Register
that stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described
in 表 6-8 and 表 6-9. Note that byte 1 is the most significant byte, followed by byte 2, the least significant byte.
The first 12 bits (13 bits in Extended mode) are used to indicate temperature. The least significant byte does not
have to be read if that information is not needed.
表 6-8. Byte 1 of Temperature Register (1)
D7 D6 D5 D4 D3 D2 D1 D0
T11 T10 T9 T8 T7 T6 T5 T4
(T12) (T11) (T10) (T9) (T8) (T7) (T6) (T5)
THIGH
Measured
Temperature
TLOW
6.5.3.7 EM Bit
The Extended-Mode bit configures the device for Normal Mode operation (EM = 0) or Extended Mode operation
(EM = 1). In normal mode, the temperature register, high-limit register, and low-limit register use a 12-bit data
format. For more information on the extended mode, see the Extended Mode (EM) section.
6.5.3.8 Alert (AL Bit)
The AL bit is a read-only function. Reading the AL bit provides information about the comparator mode status.
The state of the POL bit inverts the polarity of data returned from the AL bit. When the POL bit equals 0, the AL
bit reads as 1 until the temperature equals or exceeds T(HIGH) for the programmed number of consecutive faults,
causing the AL bit to read as 0. The AL bit continues to read as 0 until the temperature falls below T(LOW) for the
programmed number of consecutive faults, when the AL bit again reads as 1. The status of the TM bit does not
affect the status of the AL bit.
6.5.3.9 Conversion Rate (CR)
The conversion rate bits, CR1 and CR0, configure the TMP102 device for conversion rates of 0.25 Hz, 1 Hz, 4
Hz, or 8 Hz. The default rate is 4 Hz. For more information on the conversion rate bits, see 表 6-5.
6.5.4 High- and Low-Limit Registers
The temperature limits are stored in the T(LOW) and T(HIGH) registers in the same format as the temperature
result, and the values are compared to the temperature result on every conversion. The outcome of the
comparison drives the behavior of the ALERT pin, which operates as a comparator output or an interrupt, and is
set by the TM bit in the configuration register.
In Comparator mode (TM = 0), the ALERT pin becomes active when the temperature equals or exceeds the
value in THIGH and generates a consecutive number of faults according to fault bits F1 and F0. The ALERT pin
remains active until the temperature falls below the indicated TLOW value for the same number of faults.
In Interrupt mode (TM = 1), the ALERT pin becomes active when the temperature equals or exceeds the value in
T(HIGH) for a consecutive number of fault conditions (as shown in 表 6-5). The ALERT pin remains active until a
read operation of any register occurs, or the device successfully responds to the SMBus Alert Response
address. The ALERT pin will also be cleared if the device is placed in Shutdown mode. When the ALERT pin is
cleared, it becomes active again only when temperature falls below T(LOW), and remains active until cleared by a
read operation of any register or a successful response to the SMBus Alert Response address. When the
ALERT pin is cleared, the above cycle repeats, with the ALERT pin becoming active when the temperature
equals or exceeds T(HIGH). The ALERT pin can also be cleared by resetting the device with the General Call
Reset command. This action also clears the state of the internal registers in the device, returning the device to
Comparator mode (TM = 0).
Both operational modes are represented in 图 6-7. 表 6-13 through 表 6-16 describe the format for the THIGH and
TLOW registers. Note that the most significant byte is sent first, followed by the least significant byte. Power-up
reset values for THIGH and TLOW are: THIGH = 80°C and TLOW = 75°C. The format of the data for THIGH and TLOW
is the same as for the Temperature Register.
表 6-13. Byte 1 Temperature RegisterHIGH (1)
D7 D6 D5 D4 D3 D2 D1 D0
H11 H10 H9 H8 H7 H6 H5 H4
(H12) (H11) (H10) (H9) (H8) (H7) (H6) (H5)
Supply Bypass
Capacitor
Pullup Resistors 0.01µF
5kΩ
TMP102
Two-Wire 1 6
Host Controller SCL SDA
2 5
GND V+
3 4
ALERT ADD0
the pullup resistors. To configure one of four different addresses on the bus, connect the ADD0 pin to either the
GND, V+, SDA, or SCL pin.
7.2.2 Detailed Design Procedure
Place the TMP102 device in close proximity to the heat source that must be monitored, with a proper layout for
good thermal coupling. This placement verifies that temperature changes are captured within the shortest
possible time interval. To maintain accuracy in applications that require air or surface temperature measurement,
care must be taken to isolate the package and leads from ambient air temperature. A thermally-conductive
adhesive is helpful in achieving accurate surface temperature measurement.
The TMP102 device is a very low-power device and generates very low noise on the supply bus. Applying an RC
filter to the V+ pin of the TMP102 device can further reduce any noise that the TMP102 device can propagate to
other components. R(F) in 图 7-2 must be less than 5 kΩ and C(F) must be greater than 10 nF.
Supply Voltage
Device R(F) ≤ 5 kΩ
SCL SDA
GND V+
C(F) ≥ 10 nF
ALERT ADD0
100
95
90
85
80
Temperature (qC)
75
70
65
60
55
50
45
40
35
30
25
-1 1 3 5 7 9 11 13 15 17 19
Time (s)
Via to Power or
Ground Plane
SCL SDA
Supply Voltage
GND V+
ALERT ADD0
Supply Bypass
Capacitor
Heat Source
8.6 术语表
TI 术语表 本术语表列出并解释了术语、首字母缩略词和定义。
9 Revision History
注:以前版本的页码可能与当前版本的页码不同
Changes from Revision H (December 2018) to Revision I (June 2024) Page
• 通篇更新了表格、图和交叉参考的编号格式....................................................................................................... 1
• 将提到 I2C 的旧术语实例通篇更改为控制器和目标............................................................................................ 1
• 通篇更改了“转换时间”....................................................................................................................................1
• 通篇更改了工作电流、关断电流、平均和延迟静态电流..................................................................................... 1
• Changed the SCL pin description in Pin Functions table................................................................................... 3
• Removed machine model (MM) from ESD Ratings section............................................................................... 4
• Changed DRL package Thermal Information section.........................................................................................4
• Changed "Conversion time" in Electrical Characteristics table.......................................................................... 5
• Added Average quiescent current at 1Hz conversion mode in Electrical Characteristics table......................... 5
• Changed Average quiescent current at 4Hz conversion mode in Electrical Characteristics table..................... 5
• Changed Average quiescent current when serial bus active, SCL frequency = 400 kHz in Electrical
Characteristics table........................................................................................................................................... 5
• Changed Average quiescent current when serial bus active, SCL frequency = 2.85MHz in Electrical
Characteristics table........................................................................................................................................... 5
• Changed the frequency from 3.4 to 2.85 MHz in the POWER SUPPLY section of the Electrical Characteristics
table.................................................................................................................................................................... 5
• Changed shutdown current for both serial bus inactive and active, SCL frequency = 400 kHz in Electrical
Characteristics table........................................................................................................................................... 5
• Changed shutdown current when serial bus active, SCL frequency = 2.85 MHz in Electrical Characteristics
table.................................................................................................................................................................... 5
• Changed Average Quiescent Current vs Temperature, Shutdown Current vs Temperature, Conversion Time
vs Temperature, and Quiescent Current vs Bus Frequency graphs in the Typical Characteristics section........7
• Changed the Interrupt Mode (TM=1) section....................................................................................................16
www.ti.com 30-Jul-2024
PACKAGING INFORMATION
Orderable Device Status Package Type Package Pins Package Eco Plan Lead finish/ MSL Peak Temp Op Temp (°C) Device Marking Samples
(1) Drawing Qty (2) Ball material (3) (4/5)
(6)
TMP102AIDRLR ACTIVE SOT-5X3 DRL 6 4000 RoHS & Green NIPDAU | NIPDAUAG Level-1-260C-UNLIM -40 to 125 CBZ Samples
TMP102AIDRLT OBSOLETE SOT-5X3 DRL 6 TBD Call TI Call TI -40 to 125 CBZ
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of <=1000ppm threshold. Antimony trioxide based
flame retardants must also meet the <=1000ppm threshold requirement.
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead finish/Ball material - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead finish/Ball material values may wrap to two
lines if the finish value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com 30-Jul-2024
• Automotive : TMP102-Q1
• Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com 25-Sep-2024
B0 W
Reel
Diameter
Cavity A0
A0 Dimension designed to accommodate the component width
B0 Dimension designed to accommodate the component length
K0 Dimension designed to accommodate the component thickness
W Overall width of the carrier tape
P1 Pitch between successive cavity centers
Sprocket Holes
Q1 Q2 Q1 Q2
Pocket Quadrants
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com 25-Sep-2024
Width (mm)
H
W
Pack Materials-Page 2
PACKAGE OUTLINE
DRL0006A SCALE 8.000
SOT - 0.6 mm max height
PLASTIC SMALL OUTLINE
1.7
1.5
PIN 1 A
ID AREA
1
6
4X 0.5
1.7
2X 1
1.5
NOTE 3
4 2X 0 -10
3
2X 4 -10
0.6 MAX
C
SEATING PLANE
0.18
6X 0.05 C
0.08
SYMM
SYMM
0.27
6X
0.15
0.1 C A B
0.4
6X 0.05 C
0.2
4223266/E 07/2024
NOTES:
1. All linear dimensions are in millimeters. Any dimensions in parenthesis are for reference only. Dimensioning and tolerancing
per ASME Y14.5M.
2. This drawing is subject to change without notice.
3. This dimension does not include mold flash, protrusions, or gate burrs. Mold flash, protrusions, or gate burrs shall not
exceed 0.15 mm per side.
4. Reference JEDEC registration MO-293 Variation UAAD
www.ti.com
EXAMPLE BOARD LAYOUT
DRL0006A SOT - 0.6 mm max height
PLASTIC SMALL OUTLINE
6X (0.67)
SYMM
1
6X (0.3) 6
SYMM
4X (0.5)
4
3
(R0.05) TYP
(1.48)
SOLDERMASK DETAILS
4223266/E 07/2024
NOTES: (continued)
www.ti.com
EXAMPLE STENCIL DESIGN
DRL0006A SOT - 0.6 mm max height
PLASTIC SMALL OUTLINE
6X (0.67)
SYMM
1
6X (0.3) 6
SYMM
4X (0.5)
4
3
(R0.05) TYP
(1.48)
4223266/E 07/2024
NOTES: (continued)
8. Laser cutting apertures with trapezoidal walls and rounded corners may offer better paste release. IPC-7525 may have alternate
design recommendations.
9. Board assembly site may have different recommendations for stencil design.
www.ti.com
重要声明和免责声明
TI“按原样”提供技术和可靠性数据(包括数据表)、设计资源(包括参考设计)、应用或其他设计建议、网络工具、安全信息和其他资源,
不保证没有瑕疵且不做出任何明示或暗示的担保,包括但不限于对适销性、某特定用途方面的适用性或不侵犯任何第三方知识产权的暗示担
保。
这些资源可供使用 TI 产品进行设计的熟练开发人员使用。您将自行承担以下全部责任:(1) 针对您的应用选择合适的 TI 产品,(2) 设计、验
证并测试您的应用,(3) 确保您的应用满足相应标准以及任何其他功能安全、信息安全、监管或其他要求。
这些资源如有变更,恕不另行通知。TI 授权您仅可将这些资源用于研发本资源所述的 TI 产品的应用。严禁对这些资源进行其他复制或展示。
您无权使用任何其他 TI 知识产权或任何第三方知识产权。您应全额赔偿因在这些资源的使用中对 TI 及其代表造成的任何索赔、损害、成
本、损失和债务,TI 对此概不负责。
TI 提供的产品受 TI 的销售条款或 ti.com 上其他适用条款/TI 产品随附的其他适用条款的约束。TI 提供这些资源并不会扩展或以其他方式更改
TI 针对 TI 产品发布的适用的担保或担保免责声明。
TI 反对并拒绝您可能提出的任何其他或不同的条款。IMPORTANT NOTICE