h18248 Spec Sheet Dell Emc Powerscale - Pdf.external
h18248 Spec Sheet Dell Emc Powerscale - Pdf.external
h18248 Spec Sheet Dell Emc Powerscale - Pdf.external
All-Flash Nodes
PowerScale F900
PowerScale F600
PowerScale F200
The PowerScale all-flash storage platforms - powered by the PowerScale OneFS operating system - provide a powerful yet simple
scale-out storage architecture to speed up access to massive amounts of unstructured data while dramatically reducing cost and
complexity. Powered by the new OneFS operating system, the platforms are available in several product lines:
• PowerScale F600: With NVMe drives, the F600 provides larger capacity with massive performance in a cost-effective compact
form factor to power the most demanding workloads. Each node allows you to scale raw storage capacity from 15.36 TB to 122.8
TB per node and up to 30.96 PB of raw storage per cluster. The F600 includes inline software data compression and deduplication.
The minimum number of nodes per cluster is three while the maximum cluster size is 252 nodes. The F600 is best suited for M&E
studios, hospitals and financials that need performance and capacity for demanding workloads
• PowerScale F200: Provides the performance of flash storage in a cost-effective form factor to address the needs of a wide variety
of workloads. Each node allows you to scale raw storage capacity from 3.84 TB to 30.72 TB per node and up to 7.7 PB of raw
capacity per cluster. The F200 includes in-line compression and deduplication. The minimum number of PowerScale nodes per
cluster is three while the maximum cluster size is 252 nodes. The F200 is best suited for remote offices, small M&E workloads,
small hospitals, retail outlets, IoT, factory floor and other similar deployment scenarios.
• Isilon F800: Provides massive performance and capacity. It delivers up to 250,000 IOPS and up to 15 GB/s aggregate throughput
in a single chassis configuration and up to 15.75M IOPS and up to 945 GB/s of aggregate throughput in a 252 node cluster. Each
chassis houses 60 SSDs with a capacity choice of 1.6 TB, 3.2 TB, 3.84 TB, 7.68 TB or 15.36 TB per drive. This allows you to scale
raw storage capacity1 from 96 TB to 924 TB in a single 4U chassis and up to 58 PB raw storage in a single cluster.
• Isilon F810: Provides massive performance and capacity along with inline data compression and deduplication capabilities to
deliver extreme efficiency. The F810 delivers up to 250,000 IOPS and up to 15 GB/sec aggregate throughput in a single chassis
configuration and up to 15.75M IOPS and up to 945 GB/s of aggregate throughput in a 252 node cluster. Each F810 chassis
houses 60 SSDs with a capacity choice of 3.84 TB, 7.68 TB or 15.36 TB per drive. This allows you to scale raw storage capacity
from 230 TB to 924 TB in a 4U chassis and up to 58 PB of raw storage in a single cluster.
1
Values at <25° C are reflective of more steady state maximum values during normal operation
F600 ATTRIBUTES & OPTIONS 1.92 TB SSD 3.84 TB SSD 7.68 TB SSD 15.36 TB SSD
1
Values at <25° C are reflective of more steady state maximum values during normal operation
F200 ATTRIBUTES & OPTIONS 960 GB SSD 1.92 TB SSD 3.84 TB SSD 7.68 TB SSD
Raw node capacity 3.84 TB 7.68 TB 15.36 TB 30.72 TB
Front-end networking (per node) Dual port 25G NIC supporting 10G or 25G connections (SFP+/SFP28)
2 InfiniBand connections with QDR links or Dual port 25G NIC supporting 10G or 25G connections
Infrastructure networking (per node)
(SFP+/SFP28)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
CLUSTER
F200 F600 F900
ATTRIBUTES
Number of nodes 3 to 252 3 to 252 3 to 252
Front-End networking (per node) 2 x 10GbE (SFP+) or 2 x 25GbE (SFP28) or 2 x 40GbE (QSFP+)
Infrastructure networking (per node) 2 InfiniBand connections supporting QDR links or 2 x 40GbE (QSFP+)
F810 ATTRIBUTES & OPTIONS 3.84 TB SSD 7.68 TB SSD 15.36 TB SSD
Front-End networking (per node) 2 x 10GbE (SFP+) or 2 x 25GbE (SFP28) or 2 x 40GbE (QSFP+)
Isilon hybrid storage platforms powered by the OneFS operating system uses a versatile yet simple scale-out architecture to speed
access to massive amounts of data. The hybrid platforms are highly flexible and strikes the balance between large capacity and
high-performance storage to provide support for a broad range of enterprise file workloads. The hybrid storage platforms are
available in four product lines:
• Isilon H400: Provides a balance of performance, capacity and value to support a wide range of file workloads. The H400 delivers
up to three GB/s bandwidth per chassis and provides capacity options ranging from 120 TB to 960 TB per chassis.
• Isilon H500: This versatile hybrid platform delivers up to five GB/s bandwidth per chassis with a capacity ranging from 120 TB to
960 TB per chassis. The H500 is an ideal choice for organizations looking to consolidate and support a broad range of file
workloads on a single platform.
• Isilon H5600: Combines massive scalability – 1.28 PB (raw) per chassis – and up to eight GB/s bandwidth – in an efficient, highly
dense, deep 4U chassis. The H5600 also includes inline compression and deduplication capabilities. The H5600 is designed to
support a wide range of demanding, large-scale file applications and workloads.
• Isilon H600: Designed to provide high performance at value, delivers up to 120,000 IOPS and up to 12 GB/s bandwidth per
chassis. The H600 is ideal for HPC workloads that don’t require the extreme performance of all-flash.
OneFS 8.1 or later except for self-encrypting drive options which require OneFS
Operating system
8.1.0.1 or later.
Infrastructure (back-end) networking (per node) 2 InfiniBand connections with QDR links or 2 x 10 GbE (SFP+)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
OneFS 8.1 or later except for self-encrypting drive options which require OneFS
Operating system
8.1.0.1 or later.
Cache (per node) Solid state drives (SSD) (1.6 TB or 3.2 TB) 1 or 2
Front-end networking (per node) 2 x 10GE (SFP+) or 2 x 25GbE (SFP28) or 2 x 40GbE (QSFP+)
Infrastructure (back-end) networking (per node) 2 InfiniBand connections with QDR links or 2 x 40GbE (QSFP+)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
Front-end networking (per node) 2 x 10GE (SFP+) or 2 x 25GbE (SFP28) or 2 x 40GbE (QSFP+)
Infrastructure (Back-End) networking (per node) 2 InfiniBand connections with QDR links or 2 x 40GbE (QSFP+)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
OneFS 8.1 or later except for self-encrypting drive options which require
Operating system
OneFS 8.1.0.1 or later
Cache (per node) solid state drives (SSD) (1.6 TB or 3.2 TB) 1 or 2
Front-end networking (per node) 2 x 10GE (SFP+) or 2 x 25GbE (SFP28) or 2 x 40GbE (QSFP+)
Infrastructure (back-end) networking (per node) 2 InfiniBand connections with QDR links or 2 x 40GbE (QSFP+)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
Number of chassis 1 to 63
Raw cluster capacity 120 TB to 60.4 PB 120 TB to 60.4 PB 800 TB to 80.64 PB 72 TB to 9.0 PB
Isilon offers two highly efficient and massively scalable archive storage solutions. Both nodes use a modular architecture while
dramatically reducing cost and complexity and both platforms utilize a dense hardware design that provides four nodes within a
single 4U chassis
• Isilon A200: is an ideal active archive storage solution that combines near-primary accessibility, value, and ease of use. The A200
provides between 120 TB to 960 TB per chassis and scales to 60 PB in a single cluster.
Operating system OneFS 8.1 or later except for self-encrypting drive options which require OneFS 8.1.0.1 or later.
Infrastructure networking (per node) 2 InfiniBand connections with QDR links or 2 X 10GbE (SFP)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
Operating system OneFS 8.1 or later except for self-encrypting drive options which require OneFS 8.1.0.1 or later.
Infrastructure networking (per node) 2 InfiniBand connections with QDR links or 2 X 10GbE (SFP+)
1
Values at <25° C are reflective of more steady state maximum values during normal operation
Number of chassis 1 to 63
PowerScale Attributes
PRODUCT ATTRIBUTES
Distributed fully symmetric clustered architecture that combines modular storage with OneFS operating
Scale-out architecture
system in a single volume, single namespace and single filesystem
Four self-contained Isilon nodes include server, software, HDDs and SSDs in a 4U rack-mountable
Modular design chassis. 1U or 2U Rack-mountable PowerScale node that integrates into existing PowerScale and Isilon
clusters with backend Ethernet or InfiniBand connectivity
PowerScale OneFS distributed file system creates a cluster with a single file system and single global
Operating system
namespace. It is fully journaled, fully distributed, and has a globally coherent write/read cache
No-single-point-of-failure. Self-healing design protects against disk or node failure; includes back-end
High availability
intra-cluster failover
A cluster can scale up to 252 Isilon nodes. Minimum number of Isilon nodes per cluster is four. Minimum
Scalability
number of PowerScale nodes per cluster is three. Add nodes to scale performance and capacity
Data protection FlexProtect file-level striping with support for N+1 through N+4 and mirroring data protection schemes
Supports two ports of Fibre Channel (8G) that allows for two-way NDMP connections and two ports of
2-way NDMP
standard 10GbE connectivity
Data retention SmartLock policy-based retention and protection against accidental deletion
File system audit capability to improve security and control of your storage infrastructure and address
Security
regulatory compliance requirements
SmartDedupe data deduplication option, which can reduce storage requirements by up to 35 percent.
Efficiency
Inline data reduction and compression available on F200, F600, F900, F810 and H5600
Policy-based automated tiering options including SmartPools and CloudPools software to optimize
Automated storage tiering
storage resources and lower costs
NFSv3, NFSv4, NFS Kerberized sessions (UDP or TCP), SMB1 (CIFS), SMB2, SMB3, SMB3-CA,
Network protocol support
Multichannel, HTTP, FTP, NDMP, SNMP, LDAP, HDFS, S3, ADS, NIS reads/writes
Data replication SyncIQ fast and flexible one-to-many file-based asynchronous replication between clusters
Power factor is a measure of how effectively you are using electricity. The power factor of an AC electrical power system is defined as the ratio of
the real power absorbed by the load to the apparent power flowing in the circuit and is a dimensionless number in the closed interval of −1 to 1. A power
factor of less than one indicates the voltage and current are not in phase, reducing the instantaneous product of the two.
For max power consumption information during unexpected environmental conditions, please refer to the “Site Preparation and Planning Guide”.
POWER SUPPLY: key Specifications and Efficiency for F200, F600 and F900
Operating Environment: 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment
POWER SUPPLY: F800 and F810: Dual-redundant, hot-swappable 1450W power supplies with power factor correction (PFC); rated for input voltage
180 – 265 VAC (optional rack mount step-up transformer for 90-130 VAC input regions)
Power factor and efficiency rate for F800 and F810 PSU
H400 and H500: Dual-redundant, hot-swappable 1050W (low line) 1100W (high line) power supplies with power factor correction (PFC); rated for
input voltages 90 - 130 VAC (low line) and 180-264 VAC (high line)
Power factor and efficiency rate for H400 and H500
System Load Efficiency PF
10% 86.00% 0.918
20% 92.95% 0.967
30% 93.93% 0.970
40% 94.41% 0.972
50% 94.49% 0.981
60% 94.11% 0.986
70% 94.04% 0.990
80% 93.86% 0.992
90% 93.63% 0.995
100% 93.25 0.996
H5600 and H600: Dual-redundant, hot-swappable 1450W power supplies with power factor correction (PFC); rated for input voltage 180 – 265 VAC
(optional rack mount step-up transformer for 90-130 VAC input regions)
A200 and A2000: Dual-redundant, hot-swappable 1050W (low line) 1100W (high line) power supplies with power factor correction (PFC); rated for input
voltages 90 - 130 VAC (low line) and 180-264 VAC (high line)
DIMENSIONS / WEIGHT:
MINIMUM SERVICE CLEARANCES Front: 40” (88.9 cm), rear: 42” (106.7 cm)
The individual devices used in this product are approved under a unique regulatory model identifier that is affixed to each individual
device rating label, which may differ from any marketing or product family name in this datasheet.
For additional information see http://support.dellemc.com under the Safety & EMI Compliance Information tab.
Learn more about Dell Contact a Dell EMC Expert View more resources Join the conversation
Technologies Storage with #DellEMCStorage