Design Optimizations of LLC Resonant Converters
Design Optimizations of LLC Resonant Converters
Master of Science
in
Electrical Engineering
APPROVED
December 3, 2021
Blacksburg, Virginia
(Abstract)
LLC resonant converters have been a popular choice for DC-DC converters due to their high
efficiency, high power density, and hold-up capability in power supplies for communication
systems, datacenters, consumer electronics, and automobiles. With the rapid development of wide-
bandgap devices and novel magnetic materials, the push for higher switching frequencies to
To demonstrate high efficiency and high power density, the Center for Power Electronics
Systems (CPES) at Virginia Tech designed an 800W, 1MHz 400V/12V LLC converter for future
datacenters, which could achieve a peak efficiency of 97.6% and a power density of 900 W/in3.
However, with the ever-increasing demand for online services, the performance of power delivery
The focus of this thesis is improving the performance of CPES’ previous 400V/12V LLC
converter by investigating different aspects of its design and operation. Ultimately, design
guidelines are proposed, and improvements are demonstrated to effectively achieve higher
efficiency and higher power density than the previous CPES converter.
Multiple aspects of the LLC converter’s design and structure are investigated to further
improve its performance, and three main areas are the focus of this thesis. The output-side
termination design of the planar transformer is investigated and modeled, and design guidelines
for filter capacitor selection are provided for optimal efficiency. Next, the existing shielding
technique for matrix transformers, which helps reduce common-mode (CM) noise without
modifications have been proposed to improve its efficiency. Thirdly, the LLC converter’s
switching frequency is optimized to improve its performance over the previous CPES converter.
Finally, the hardware results with the proposed improvements are demonstrated, and the
converter’s performance is compared with the previous CPES converter as well as other recent
proposed solutions.
Design Optimizations of LLC Resonant Converters
The electricity demand by datacenters has been growing exponentially over the past few
decades, especially due to the boom of artificial intelligence in addition to other internet services.
This has resulted in a requirement to continually improve the efficiencies of the power delivery
from the grid, through the datacenter power architecture, and finally to the loads on the server
racks. The overall datacenter power architecture has been improved over time to improve the total
efficiency. However, the performance of each stage along the power architecture must be improved
The focus of this thesis is to improve the performance of the 400V/12V DC-DC stage for
future datacenters. Previously, the Center for Power Electronics Systems (CPES) at Virginia Tech
developed a 1MHz 800W 400V/12V LLC converter with 97.6% peak efficiency and 900W/in3
power density. However, the performance of the converter must be further improved to stay ahead
of the competition and keep in pace with the increasing energy demand.
Multiple aspects of the LLC converter’s design and structure are investigated to further
improve its performance, and three main areas are the focus of this thesis. Firstly, the high-
frequency termination design, or how different components are interconnected and arranged, is
studied, and a capacitance selection guideline is proposed to maximize the efficiency. Next, the
existing shielding technique for matrix transformers, which helps reduce common-mode (CM)
issues, and modifications have been proposed to improve its efficiency. Thirdly, the LLC
converter’s switching frequency is optimized to improve its performance over the previous CPES
converter. Finally, the hardware results with the proposed improvements are demonstrated, and
the converter’s performance is compared with the previous CPES converter as well as other recent
proposed solutions.
Acknowledgments
I would like to express my heartfelt gratitude to my advisor, Dr. Qiang Li, for his guidance
and support through the entire duration of my master’s degree. His profound knowledge,
experience, and research attitude have been a blessing for me ever since I started my research. I
have learned so much about power electronics and research from him, and for that I am eternally
grateful.
I would also like to acknowledge my committee members, Dr. Dong Dong and Dr. Steve
Southward, for their support, comments, and suggestions. I would also like to thank all the staff at
CPES, whose help allowed me to focus solely on research without worrying about the paperwork.
It has also been an honor to work with the exceptionally talented students at CPES, whose
eagerness to share their knowledge without hesitation is something that I really appreciate and will
carry forward.
No words can accurately describe my love and gratitude toward my parents, Girija Prakash
and Om Prakash, who have been my lifeline throughout my existence, [A1] and wholeheartedly
supported me in my endeavors. I would also like to thank my friends in Blacksburg, who have
helped make this my home away from home. I will cherish every memory I have with them.
Finally, special thanks to the Power Management Consortium and High Density Integration
vi
Table of Contents
vii
4.3 Resonant Converter Performance Evaluation ............................................................... 70
References ..................................................................................................................................... 88
viii
List of Figures
Fig. 1.8. Integration process for the four-leg matrix transformer with reduced flux density: (a)
original matrix transformer, (b) matrix transformer with flux cancelation, (c) before core
Fig. 1.9. Four-layer PCB winding transformer stack-up: (a) cross-sectional view, and (b) top view.
......................................................................................................................................................... 9
Fig. 1.10. PCB winding arrangement for matrix transformer: (a) Layer 1: Secondary, (b) Layer 2:
Fig. 1.12. Measured efficiency curve for previous CPES LLC converter. ................................... 11
Fig. 2.1. Winding arrangement with good interleaving but high termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
Fig. 2.2. Winding arrangement with worse interleaving but low termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
ix
Fig. 2.3. Modified schematic of center-tapped rectifier with split output filter capacitors: (a)
common output filter capacitors, and (b) split output filter capacitors. ........................................ 18
Fig. 2.4. Secondary-side termination in the previous CPES 400V/12V LLC converter: (a) top layer,
(b) bottom layer, and (c) 3D view of component and via layout in one elemental transformer. .. 19
Fig. 2.5. (a) Parasitic loop connecting 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡, and (b) equivalent schematic with parasitic
Fig. 2.6. (a) Secondary-side termination schematic with parallel ringing loop, and (b) equivalent
Fig. 2.7. Magnitude, real and imaginary parts of Z against frequency. ........................................ 24
Fig. 2.8. Modified equivalent circuit model including capacitor ESR. ........................................ 26
Fig. 2.11. Schematic of one elemental transformer with CT rectifiers and loop parasitics. ......... 30
Fig. 2.12. Equivalent circuit model of transformer reflected to primary side. ............................. 30
Fig. 2.13. Magnetizing inductance measurement: (a) open-circuit secondary, (b) equivalent circuit
Fig. 2.14. Leakage inductance measurement: (a) short-circuit secondary, (b) equivalent circuit
Fig. 2.15. (a) 16034E probe with device under test (DUT), and (b) capacitor parameter
measurement. ................................................................................................................................ 33
Fig. 2.17. Measured and modeled equivalent transformer resistance versus frequency. .............. 35
x
Fig. 3.1. (a) Schematic of LLC converter with switching nodes, and (b) CM noise sources and
Fig. 3.2. (a) LLC converter schematic, and (b) six-layer PCB stack-up....................................... 40
Fig. 3.3. Equipotential shield windings: (a) shield and secondary windings, and (b) potential
Fig. 3.4. Modified shielding technique with shielding as part of the primary. ............................. 42
Fig. 3.5. PCB winding arrangement for proposed shielding: (a) transformer schematic with
proposed shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4: primary, and (e)
Fig. 3.6. Hardware prototype of 400V/12V LLC with proposed shielding. ................................. 44
Fig. 3.7. Hardware testing results of 400V/12V LLC with proposed shielding: (a) CM noise
Fig. 3.8. Waveforms of interest on the secondary side during one-half of a cycle of operation. . 46
Fig. 3.9. 𝑉𝐷𝑆 waveforms of SRs during the turn-off instant: (a) first half-cycle, (b) second half-
Fig. 3.10. Conducting layer proximities with the original shielding technique: (a) first half-cycle,
Fig. 3.11. 3D FEA simulated leakage inductances of secondary windings with original shielding.
....................................................................................................................................................... 49
Fig. 3.12. Conducting layer proximities with the modified shielding technique: (a) first half-cycle,
Fig. 3.13. 3D FEA simulated leakage inductances of secondary windings with modified shielding.
....................................................................................................................................................... 50
xi
Fig. 3.14. PCB winding arrangement for improved shielding: (a) transformer schematic with
improved shielding, (b) Layer 2: shielding, (d) Layer 4: primary, and (e) Layer 5: shielding. .... 51
Fig. 3.15. 3D FEA simulated current density comparison between original and improved shield:
(a) Layer 2 shield in original shielding, (b) Layer 5 shield in original shielding, (c) Layer 2 shield
Fig. 3.16. Current directions in the paralleled shield windings in the improved shielding: (a)
Fig. 3.17. Electric field distribution within the layers of a PCB transformer with CT rectifiers.. 53
Fig. 3.18. Interwound parallel shield layers to homogenize the electric field around them: (a) cross-
Fig. 3.19. Current density in the paralleled shield windings with interleaved shielding: (a)
Fig. 3.20. PCB winding arrangement for improved and interleaved shielding: (a) transformer
schematic with improved shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4:
Fig. 3.21. Asymmetrical leakage inductance and current sharing with airgap on one end of
transformer: (a) leakage inductance path for secondary, and (b) 𝑉𝐷𝑆 of SRs during turn-off. ... 57
Fig. 3.22. Symmetrical fringing flux and current sharing with airgap in the middle of transformer:
(a) fringing flux with airgap in the middle, and (b) 𝑉𝐷𝑆 of SRs during turn-off. ........................ 57
Fig. 3.23. Efficiency reduction when moving the airgap to the middle........................................ 58
xii
Fig. 4.1. Converter losses that increase with switching frequency: (a) device switching loss, (b)
Fig. 4.2. Transformer core loss decreases with switching frequency. .......................................... 63
Fig. 4.6. Performance factor comparison at different core loss densities: (a) 𝑃𝑣 = 0.3𝑊𝑐𝑚3, and b
𝑃𝑣 = 0.7𝑊/𝑐𝑚3. ......................................................................................................................... 70
Fig. 4.12. Magnetic flux density in the transformer: (a) top view, and (b) cross-sectional view. 76
Fig. 4.13. Full-load efficiency versus power density at different frequencies. ............................. 77
Fig. 4.15. 400V/12V LLC converter operating waveforms: (a) light load (10%, 100 W), and (b)
Fig. 4.18. Comparison of the converter loss breakdown at full load. ........................................... 82
xiii
List of Tables
Table 1.3. Performance summary of other recent 400V/12V unregulated DC-DC converters. ... 12
Table 4.3. Mn-Zn ferrite materials selected for core loss testing. ................................................ 67
Table 5.1. Updated performance summary of recent 400V/12V unregulated DC-DC converters.
....................................................................................................................................................... 86
xiv
Chapter 1. Introduction
Since the turn of the century, the internet has become an integral part of almost everyone’s life,
with it being used for increasingly widespread tasks, ranging from launching space shuttles to
purchasing groceries. Moreover, with the advent of artificial intelligence, the internet traffic to and
Internet traffic increased 30,000 times from 1987 to 1997, further increasing by over a
thousand times in the next 10 years. In the past decade, with the advent of data-hungry artificial
intelligence in addition to other online services like banking, e-commerce, social media, and cloud
This trend is expected to continue into the future, as forecasts suggest that the total electricity
demand of information and communication technology (ICT) will accelerate in the 2020s to up to
1
20% of the total electricity demand, and that datacenters will take up almost around 40% of that,
Because of the increased energy demand by datacenters, big tech companies such as Google,
Amazon, Facebook, and Microsoft are building massive datacenter farms called hyperscale
datacenters to serve small- and medium-sized enterprises, which can consume up to 200 MW per
datacenter. The estimated annual spending on datacenter systems worldwide is almost $200
billion, out of which around 40% is estimated to be spent on the power and cooling infrastructure.
Given the rising demand for online services, efficiency gains at every stage are essential to
maintaining a sustainable level of global energy consumption, particularly for countries seeking to
2
Fig. 1.3. Traditional 12V-bus architecture for datacenters.
The datacenter power architecture is one significant area where efficiency could be improved.
Fig. 1.3 shows the conventional 12V bus architecture for datacenters, with the approximate
efficiencies of each stage. The 60Hz transformer is followed by the AC/DC and the DC/AC stages
necessary to connect the uninterruptible power supply (UPS). This is followed by the power
distribution unit (PDU), which includes another 60Hz transformer, as well as switches and relays
to distribute the AC voltage to different server cabinets. Within each server cabinet, there are
power supply units (PSUs) consisting of the AC/DC and isolated DC/DC stages, which are front-
end converters, finally followed by the voltage regulators (VRs) that supply various loads. Adding
up the efficiencies of these numerous stages results in a net efficiency of only 73% [3][4].
Due to the low bus voltage and multiple conversion stages in the traditional 12V-bus
architecture, Google came up with an improved architecture with a higher bus voltage of 48V
3
[5][6]. The PDU now has only switches and relays to distribute the power to different cabinets,
and hence has higher efficiency. Moreover, the UPS is now moved to the 48V DC bus inside the
server racks, thereby eliminating the AC/DC and DC/AC stages required to connect the UPS to
the AC side, and hence reducing the number of power-conversion stages. This fact, coupled with
the higher bus voltage having lower i2R losses, results in a much higher net efficiency of 80%, 7%
higher than the traditional 12V bus architectures; this is approximately equal to the energy
[A2]
Recently, the 400V DC bus architecture has gained traction due to its much lower i2R losses,
and subsequently lower cost due to fewer transmission cables as compared to the 48V bus
architecture [8][9]. This results in a higher overall power architecture efficiency of 83%, 10%
higher than the traditional 12V architecture; this amount is approximately equal to the energy
produced by 47 nuclear power plants every month. This architecture requires a DC/DC converter
that can directly step-down the 400V bus voltage to 12V to supply the VRs. Industry standards for
this on-board converter were proposed by the International Electronics Manufacturing Initiative
4
Table 1.1. iNEMI specifications for the DC/DC converter.
The iNEMI specifications for the DC-DC converter require a high voltage step-down ratio, high
output-current capability, high efficiency, and high power density, which is challenging. Hard-
switching pulse-width modulation (PWM) converters cannot achieve the required efficiency and
power density due to their high switching losses at higher frequencies. Among soft-switching
PWM converters, different candidates, such as asymmetrical half-bridge converters and phase-
shifting full-bridge PWM converters, have been implemented as DC/DC converters [11][12].
However, they must sacrifice their normal operation efficiency to accommodate the large input
Resonant converters are great choices for DC/DC converters due to their ability to achieve soft-
switching over the entire load range and the lower turn-off losses incurred for their primary devices
(as compared to their hard-switching counterparts), resulting in high efficiencies and high power
densities. Among them, LLC converters have been demonstrated to be promising candidates for
DC/DC converters, due to their ability to achieve high gains for hold-up, while maintaining high
5
efficiencies during normal operations, while also reducing the electromagnetic interference due to
However, for a high output current of 67A (12V, 800W), the transformer’s secondary winding
loss and the secondary-rectifier (SR) conduction loss are too high to achieve the required
efficiencies. Hence, multiple SRs and secondary windings must be effectively paralleled to reduce
the conduction losses, as shown in Fig. 1.6. However, at the locations denoted by the red dots in
Fig. 1.6, the termination loss is too high when connecting multiple SRs to the secondary windings.
To address these issues, CPES proposed a novel structure, termed a matrix transformer,
wherein the transformer is broken down into multiple smaller transformers that are then connected
such that the primary windings are in series and the secondary windings are in parallel [16][17].
Most recently, [18] proposed a matrix transformer consisting of four smaller transformers, each
with a 4:1 turns ratio, as shown in Fig. 1.7. This way, as the secondary current is distributed equally
among the paralleled secondary windings, it correspondingly reduces the net secondary winding
loss. In addition, the SR termination loss can be minimized as the SRs don’t have to be paralleled
6
on a single secondary winding, but instead can be placed individually on the paralleled secondary
[A3]
(a) (b)
(c) (d)
Fig. 1.8. Integration process for the four-leg matrix transformer with reduced flux density: (a)
original matrix transformer, (b) matrix transformer with flux cancelation, (c) before core
integration, and (d) after core integration.
7
The process of integrating the four elementary transformers into one matrix transformer is
shown in Fig. 1.8. The original matrix transformer with four sets of UI[A4] cores has excessive core
loss due to the redundant core legs, as shown in Fig. 1.8 (a). However, two UI cores can be
combined if the primary turns are wound in opposite directions, and hence the vacant legs can be
removed since they have equal and opposite magnetic fluxes; this results in two sets of UI cores,
as shown in Fig. 1.8 (b). Furthermore, core 2 can be rotated by 1800, as shown in Fig. 1.8 (c), such
that upon integration of all four elemental transformers under one core, the magnetic flux in the
plate is evenly distributed. This way, only half the flux from each leg flows to the two adjacent
Using traditional litz-wires for the transformer windings is difficult for manufacturing and
mass production, and hence printed circuit board (PCB) -based windings have been used in recent
works, due to the ease with which they can be designed and manufactured [16][17][19]. Fig. 1.9
(a) shows the four-layer PCB layer stack for the matrix transformer in [18]. The two primary layers
are sandwiched in between the two secondary layers on the top and bottom layers. This way, the
SRs and output filter capacitors can be placed directly on the secondary windings to minimize the
termination losses and secondary winding leakage inductance, as shown in Fig. 1.9 (b).
(a) (b)
Fig. 1.9. Four-layer PCB winding transformer stack-up: (a) cross-sectional view, and (b) top
view.
8
[A5]
(a) (b)
(c) (d)
Fig. 1.10. PCB winding arrangement for matrix transformer: (a) Layer 1: Secondary, (b) Layer 2:
Primary, (c) Layer 3: Primary, and (d) Layer 4: Secondary.
Fig. 1.10 shows the PCB winding arrangement for the matrix transformer; the yellow arrows
show the current direction in the windings. The 16 primary turns are wound among the four
elemental transformers between the two primary layers. Each elemental transformer has two
primary turns per layer, with vias being employed to connect the two layers between each
elemental transformer. The primary terminals are right next to each other to minimize the leakage
9
inductance and termination loss. The secondary side employs center-tapped rectification, and
hence only one set of SRs are active in each half-cycle of operation. The SRs and output filter
capacitors are placed directly on the winding, which allows the secondary current to perfectly
interleave with the primary, resulting in minimum leakage inductance and AC termination loss.
Moreover, the SRs conducting in one half-cycle are alternatively placed on the two secondary
layers to have symmetrical interleaving between the primary and secondary currents.
A hardware prototype for the 800W 380V/12V LLC DC-DC converter running at a fixed
frequency of 1 MHz was developed as shown in Fig. 1.11, and the specifications for the proposed
Component Parameters
Resonant Frequency 1MHz
Dead Time 90ns
Transformer Turns Ratio 16:1
Primary Devices PGA26E08
Secondary Devices BSC0500NSI
Primary Driver Si8273
Secondary Drivers FAN3122
Resonant Capacitor 71nF
Resonant Inductance 312nH
Magnetizing Inductance 25uH
10
Fig. 1.12. Measured efficiency curve for previous CPES LLC converter.
The power density of the 800W converter is 930 W/in3, and the measured efficiency curve is
shown in Fig. 1.12. It can achieve 92.5% at light load (10% load), 97.6% peak, and 97.2% at full
load, all of which satisfies the iNEMI requirements, as shown by the pink curve in Fig. 1.12.
which has resulted in significant interest to realize the 400V-bus architecture for datacenters.
Hence, the 400V/12V DC-DC converter has been the recent research focus of many groups
converter [18] are listed in Table 1.3. Some research [20],[21] and [24] has demonstrated different
ways the partial-turn transformer concept can be implemented effectively for the 380V/12V LLC
converter, resulting in high power densities and efficiencies. One research work [22] uses series-
connected low-voltage primary Si MOSFETs to reduce the device losses. Another example [23]
is ViCOR’s 800W bus converter module that offers high power density.
11
Table 1.3. Performance summary of other recent 400V/12V unregulated DC-DC converters.
The efficiency values with a * denote that they do not include the device’s driving losses. For
example, [22] reports 98.3% peak efficiency, which is higher than that of the previous CPES work
due to lower device losses. However, it has significantly higher device driving losses (~9W) from
switching 16 Si MOSFETs, and this results in an estimated 97% peak efficiency. The power
density values with a ** denote that they do not include the controller circuit as part of the power
density.
To summarize, new developments in magnetic and converter designs are pushing the
efficiencies and power densities higher, which leads to the motivation to attempt to further improve
the performance of the CPES 400V/12V LLC converter such that it can compete with state-of-the-
art performance levels. This is the primary objective of this thesis. Three major areas of potential
performance improvement have been identified – matrix transformer termination design analysis,
the shielding technique used to suppress common-mode (CM) noise in matrix transformers and
optimizing the switching frequency of the LLC converter to improve efficiency and power density.
In Chapter 1, the current trends in datacenter energy requirements are discussed, and how
improvements in datacenter power architecture, achieved by pushing the bus voltage from the
traditional 12V up to 400V, can help improve the overall power architecture efficiency. The 400V
12
bus requires a 400V/12V DC-DC converter with high efficiency and high power density. CPES
has developed a 400V/12V LLC converter rated at 800W, which is briefly reviewed. Moreover,
the current technology landscape of the 400V/12V DC-DC converters for future datacenters is
surveyed, leading to the motivation to further improve the performance of the CPES 400V/12V
LLC converter to (a) keep the performance improvement at pace with ever-increasing energy
In Chapter 2, different termination techniques for the high-frequency matrix transformers with
center-tapped rectifiers are discussed. The termination design must be carefully considered,
especially at high-frequency operations, where the transformer leakage inductances can result in
high AC termination losses. In this chapter, the termination design in the previous CPES
400V/12V LLC converter is analyzed. Due to the presence of output filter capacitors on both
secondary layers (top and bottom layers), there is a parasitic path between the two filter capacitor
sets that has some parasitic loop inductance, which resonates with the capacitors to result in parallel
LC resonance peaks. This behavior is analyzed, and design guidelines are provided to move the
parallel LC resonant frequency away from the converter resonant frequency in order to minimize
this impact, and hence lessen transformer impedance, at the resonant frequency. The complete
transformer including the termination is modeled and verified with hardware measurements.
In Chapter 3, the shielding technique in matrix transformers is studied. Due to the large
overlapping surface area between the primary and secondary windings in planar transformers, the
inter-winding capacitance is high. The high dV/dt in the primary side causes CM noise to flow
through the inter-winding capacitance then into the secondary side, resulting in high CM noise at
the load. To attenuate this, shield layers are placed between the primary and secondary layers and
are connected back to the primary ground, such that the induced CM noise flows back into the
13
primary side. CPES previously designed a shielding technique with conducting shield layers,
which, in addition to suppressing the CM noise, also increases the effective turns number of the
transformer, thereby reducing the primary-side loss, and improving efficiency. However, there are
inherent current-sharing issues in the converter due to asymmetrical leakage inductances in the
detail, and solutions are proposed; these are verified with hardware testing. In addition, the impact
the position of the transformer airgap relative to the PCB windings has on its leakage inductance
In Chapter 4, the switching frequency of the LLC converter is optimized. The LLC converter
operates at a fixed switching frequency, which equals the resonant frequency, when it operates as
a DC-DC transformer. Most of the losses in the converter are dependent on the switching frequency,
and hence its optimization is vital for achieving the greatest performance from the converter. To
optimize the switching frequency, the best ferrite material for the transformer core must be selected
for each switching frequency. To make this selection, the core loss densities of various materials
are measured, and their performance factors are compared to determine the best materials at
different frequency ranges. Next, the converter efficiencies and power densities are compared at
different switching frequencies, and the optimal switching frequency is selected. Finally, the
performance improvement is verified with hardware experiments carried out on the converter
Chapter 5 presents a summary of the work done in this thesis and explores options for future
work.
14
Chapter 2. Termination Analysis of High-Frequency
2.1 Introduction
The benefits of switching to PCB winding-based transformers from the traditional litz wire-
based transformers are multifold, and include easier manufacturability, strong repeatability, and a
larger surface area resulting in low-profile cores and better thermal capabilities. Moreover, the
planar magnetic windings can be pushed to higher frequencies, as compared to the traditional litz-
wire windings, hence reducing the magnetic core size [25]. However, in high-current applications,
multiple PCB layers must be paralleled in order to achieve low DC resistance. This results in an
In high-frequency, high-current planar transformers, in addition to the core loss and winding
loss, the total transformer loss also includes termination loss. The termination loss has two main
components – (a) loss from the vias, which interconnect the multiple parallel layers, and (b) loss
from the winding segments that extend outside the core for termination in the external circuitry,
Significant work has been done to study the termination in planar transformers; multiple
aspects, such as the optimal number of PCB layers, interleaving and relative positioning of the
primary and secondary layers, and optimally connecting the secondary winding terminals to the
SRs and output filter capacitors have been studied [25][26][27]. For the four-layer planar
transformer employed for 400V/12V LLC converters, the termination for the center-tapped
15
rectifiers has been studied and optimized in the previous converters developed by CPES, as
(d) (e)
Fig. 2.1. Winding arrangement with good interleaving but high termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
(e) magnetic field intensity plot.
Fig 2.1 shows a winding arrangement in which the top and bottom layers contain the primary
windings and the middle layers are for the secondary windings. This arrangement has very good
interleaving due to the low peak magneto-motive force (MMF) in the transformer, as shown in Fig.
2.1 (c). However, the termination design becomes challenging in this arrangement, as the
secondary winding terminals in the middle layers must be connected to the SRs and output filter
capacitors on the top and bottom layers using vias, resulting in high via loss. Moreover, the SRs
and filter capacitors must be placed outside the transformer area, resulting in poor interleaving in
16
the non-overlapping area outside the transformer, as seen by the high magnetic field intensity in
Fig. 2.1 (d). The 3D finite element analysis (FEA) simulation of the secondary windings with this
176.4𝑛𝐻.
(d) (e)
Fig. 2.2. Winding arrangement with worse interleaving but low termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
(e) magnetic field intensity plot.
Fig 2.2 shows a winding arrangement in which the top and bottom layers contain the
secondary windings and the middle layers are for the primary windings. This arrangement allows
the SRs and output filter capacitors to be on the same layers as the secondary windings, which
eliminates the requirement of vias for connection. Moreover, the SRs and output capacitors can
now be placed directly on the windings themselves, as shown in Fig. 2.2 (a), resulting in much
17
better overlapping between the primary and secondary current, and hence improving both
components of the termination design. The 3D FEA simulation for the secondary windings of this
improved termination at 1 MHz results in AC resistance R sec = 1.37 𝑚Ω and leakage inductance
𝐿𝑘 = 36.6𝑛𝐻. These values are almost one-third the values obtained from the previous termination,
highlighting the fact that even with worse inherent interleaving, drastic improvements in
termination lead to much lower AC resistances and leakage inductances of the transformer.
As evident from the previous designs, the center-tapped rectifier circuit is split between the
top and bottom secondary layers, such that only one layer is required to conduct in each half-cycle.
However, this also means that the output filter capacitors must be split into two and placed on each
secondary layer to achieve an optimal termination loop. Hence, the center-tapped rectification
schematic can be redrawn with split output filter capacitors, as shown in Fig. 2.3, for one elemental
transformer, with the two sets of split output filter capacitors being named 𝐶𝑡𝑜𝑝 and 𝐶𝑏𝑜𝑡 . The red
(a) (b)
Fig. 2.3. Modified schematic of center-tapped rectifier with split output filter capacitors: (a)
common output filter capacitors, and (b) split output filter capacitors.
18
Based on this, the secondary-side termination for the four-leg matrix transformer in the
previous CPES 400V/12V LLC converter with center-tapped rectifiers was designed as shown in
(a) (b)
(c)
Fig. 2.4. Secondary-side termination in the previous CPES 400V/12V LLC converter: (a) top
layer, (b) bottom layer, and (c) 3D view of component and via layout in one elemental
transformer.
19
The four elemental transformers are separately connected to the load, as shown by the red and
black arrows pointing outward from the transformer terminals. The output filter capacitors on the
top secondary layer are labeled 𝐶𝑡𝑜𝑝 and those on the bottom secondary layer are labeled 𝐶𝑏𝑜𝑡 .
SR1, SR3, SR5, and SR7 conduct in the first half-cycle, and, along with their corresponding filter
capacitors, are colored in. SR2, SR4, SR6, and SR8 conduct in the second half-cycle, and, along
with their corresponding filter capacitors, are greyed out. Since the output currents from both half-
cycles must be merged to be sent to the load, vias are needed outside the transformer to combine
the output currents using the middle layers. The current flow arrows and the termination vias used
by the secondary current in the first half-cycle are shown in yellow, and those used in the second
Ideally, all AC components of the output current will be filtered out by the output capacitors,
resulting in only the DC current merging through the vias and going to the load. However, as will
be studied in this chapter, there is an alternative path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 that results in circulating
current, which has its own parasitic loop inductance and resistance. This inductance is shown to
resonate with the capacitors, resulting in parallel resonance at a certain frequency, which if within
the vicinity of the switching frequency, can result in increased transformer termination losses, and
hence, lower efficiencies. This phenomenon is investigated, and capacitor selection guidelines are
The split output capacitors, which are on the top and bottom layers, must be paralleled and
connected to the load. However, since the secondary current flows in opposite directions in the
two half-cycles, the positions of the SR and the filter capacitors are interchanged on the two
20
secondary layers. This results in a long path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 , as shown in Fig. 2.5 (a), which
shows the transformer layers of elemental transformer #4. The red loop indicates the secondary
current termination loop, and the yellow loop shows the path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 through the middle
layers. A simplified equivalent schematic can then be drawn as shown in Fig. 2.5 (b), in which the
[A6]
(a) (b)
Fig. 2.5. (a) Parasitic loop connecting 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 , and (b) equivalent schematic with parasitic
loop inductance 𝐿𝑠 .
The equivalent impedance model of the termination circuit must be studied to understand the
behavior of the parasitic loop. Fig. 2.6 (a) shows the modified schematic of the termination
including termination resistance 𝑅𝑡𝑒𝑟𝑚 and parasitic loop resistance 𝑅𝑠 . Fig 2.6 (b) shows the
equivalent impedance network of the secondary-side termination during the first half-cycle across
the two red dots in Fig. 2.6 (a) and includes the capacitor ringing loop.
21
It can be observed that there is a parallel resonant loop in the circuit, represented by the yellow
loop, which can result in high impedance if the loop’s resonant frequency is around the converter’s
(a) (b)
Fig. 2.6. (a) Secondary-side termination schematic with parallel ringing loop, and (b) equivalent
impedance model.
It can be realistically and reasonably assumed that 𝐶𝑡𝑜𝑝 = 𝐶𝑏𝑜𝑡 . Therefore, the net impedance
1
𝑍 = 𝑅𝑡𝑒𝑟𝑚 + ,
1 1 (2.1)
𝑍1 + 𝑍2
where 𝑍1 and 𝑍2 are the impedances of the two parallel branches, given by:
1 1
𝑍1 = 𝑎𝑛𝑑 𝑍2 = 𝑠𝐿𝑠 + + 𝑅𝑠 . (2.2)
𝑠𝐶𝑡𝑜𝑝 𝑠𝐶𝑡𝑜𝑝
22
where 𝑠 = 𝑗𝜔 , and 𝜔 is the angular frequency, given by 𝜔 = 2𝜋𝑓 . Therefore, (2.2) can be
1
𝑍 = 𝑅𝑡𝑒𝑟𝑚 + ,
𝑠𝐶𝑡𝑜𝑝 (2.3)
𝑠𝐶𝑡𝑜𝑝 + 2
1 + 𝑠 𝐿𝑠 𝐶𝑡𝑜𝑝 + 𝑠𝑅𝑠 𝐶𝑡𝑜𝑝
This results in a third-order transfer function due to the presence of the three energy-storage
To study the impact of this termination impedance on the transformer loss, the equivalent
resistance, or the real part, of the impedance network must be evaluated. To achieve this, 𝑠 = 𝑗𝜔
is substituted into (2.4), and the complex conjugate of the denominator is multiplied and divided
to result in:
The total impedance can now be separated into the real and imaginary parts as:
𝑍 = 𝑅𝑒 + 𝑗𝑋𝑒 , (2.6)
where [PPR7] 𝑅𝑒 is the equivalent resistance of the impedance network, 𝑋𝑒 is the equivalent
reactance of the impedance network. Upon further simplifying (2.5), the following expressions for
23
𝑅𝑠
𝑅𝑒 = 𝑅𝑡𝑒𝑟𝑚 + 2 2 , 𝑎𝑛𝑑 (2.7)
𝐶𝑡𝑜𝑝 𝐿2𝑠 𝜔 4 + 𝐶𝑡𝑜𝑝 𝑅𝑠 𝜔 2
2 − 4𝐶𝑡𝑜𝑝 𝐿𝑠 𝜔 2 + 4
Clearly, |𝑍|, 𝑅𝑒 and 𝑋𝑒 are a function of the frequency and can be plotted as shown in Fig. 2.7.
The blue, green, and red curves show |𝑍|, 𝑋𝑒 and 𝑅𝑒 respectively. It can be observed that at
low frequencies, the impedance network is predominantly capacitive, with infinitely high
parallel resonance between 𝐶𝑡𝑜𝑝 , 𝐶𝑏𝑜𝑡 and 𝐿𝑠 , there is a large circulating energy between the
energy storage elements, resulting in high impedance in the network at the parallel resonant
24
frequency. However, the high circulating current also passes through 𝑅𝑠 , which is in series with
𝐿𝑠 . This results in an increase in the termination resistance at parallel resonant frequency too.
Hence, 𝑅𝑒 dominates the network impedance around the parallel resonant frequency, and since it
represents the real loss in the network, its analysis is essential to study the gather information about
The parallel resonant frequency can be calculated simply by setting 𝑋𝑒 = 0 for the parallel
resonant circuit, resulting in the following expression for the parallel resonant frequency, 𝜔0 :
1
𝜔0 = . (2.9)
√0.5𝐶𝑡𝑜𝑝 𝐿𝑠
2
𝐶𝑡𝑜𝑝 𝐿𝑠 = . (2.10)
𝜔02
𝑅𝑠
𝑅𝑒 = 4 + 𝑅𝑡𝑒𝑟𝑚 .
𝜔 𝜔 2 2 (2.11)
4 (𝜔 ) − 8 (𝜔 ) + 𝜔 2 𝐶𝑡𝑜𝑝 𝑅𝑠2 + 4
0 0
𝑅𝑠
𝑅𝑙𝑜𝑤𝑓 ≈ + 𝑅𝑡𝑒𝑟𝑚 . (2.12)
4
At the resonant frequency, 𝜔 = 𝜔0 , and hence the peak resistance 𝑅𝑒𝑚𝑎𝑥 , as shown by the
25
𝐿𝑠
𝑅𝑒𝑚𝑎𝑥 = + 𝑅𝑡𝑒𝑟𝑚 . (2.14)
2𝐶𝑡𝑜𝑝 𝑅𝑠
Given that the operating frequencies of resonant converters are easily pushed to over 500 kHz,
the presence of the parallel loop resonant peak around the typical frequency range of operation is
a reason to pay attention to this behavior. For example, the equivalent termination resistance is
more than four times higher at 700 kHz than at 1 MHz, which (a) is counterintuitive as the
termination resistance increases with switching frequency, and (b) can result in much steeper
conduction losses and lower efficiencies than expected at 700 kHz. Therefore, this phenomenon
needs to be studied in detail so that its impact on the converter efficiency can be minimized.
The model assumes the capacitor to be purely reactive. However, real capacitors have parasitic
equivalent series resistances (ESRs), which could contribute to significant losses in high-output-
current applications and must also be considered in the model. Fig. 2.8 shows the modified
26
Adding the resistances will not impact the resonant frequency value. However, it will affect
the equivalent resistance 𝑅𝑒 as illustrated by the comparison curves in Fig. 2.9. Each 10 µF
capacitor has an ESR of 2 mΩ, and hence paralleling three of them results in a net ESR of
Upon considering the capacitor’s ESR, the 𝑅𝑙𝑜𝑤𝑓 , 𝑅𝑒𝑚𝑎𝑥 and 𝑅ℎ𝑖𝑔ℎ𝑓 have straightforward
𝑅𝑠 + 𝐸𝑆𝑅
𝑅′𝑙𝑜𝑤𝑓 ≈ + 𝑅𝑡𝑒𝑟𝑚 . (2.15)
4
𝐿𝑠
𝑅′𝑒𝑚𝑎𝑥 = + 𝑅𝑡𝑒𝑟𝑚 . (2.17)
2𝐶𝑡𝑜𝑝 (𝑅𝑠 + 𝐸𝑆𝑅)
It can be observed from Fig. 2.9 that for a realistic ESR value, its impact on the equivalent
termination resistance is negligible up to the resonant frequency and has a slight impact thereafter.
27
Therefore, for studies focusing on frequencies at or below the resonant frequency, and where the
𝐸𝑆𝑅 ≪ 𝑅𝑠 , the ESR can be neglected in order to simplify the model and calculations.
overshoot/undershoot during load transients, and the peak-to-peak output voltage requirements at
steady state. However, from equation (2.4), the parallel resonant frequency for the parasitic
termination loop depends on the output filter capacitance 𝐶𝑡𝑜𝑝 and the loop inductance 𝐿𝑠 . For
instance, if a capacitance value is selected that satisfies both the transient and steady-state
requirements, but results in the parallel resonant frequency being in the vicinity of the switching
frequency, this will result in high termination resistance, resulting in high conduction losses, and
Fig. 2.10 shows the equivalent termination resistance 𝑅𝑒 as a function of frequency for three
capacitance values. The transformer has sufficient winding width to accommodate three 0805-
sized capacitors each for 𝐶𝑡𝑜𝑝 and 𝐶𝑏𝑜𝑡 , and this parameter is fixed for this study.
28
From Fig. 2.10, it can be observed that by increasing the capacitance, the parallel resonant
frequency decreases. This result indicates that, although a higher capacitance is better for the load
transient and steady-state output voltage peak-to-peak requirements, it may result in high
termination resistance as the parallel resonant frequency moves much closer to the switching
frequency.
tapped rectifiers in planar transformers, as discussed in Section 2.3, the transformer impedance
must be measured and verified with the proposed model. However, it is practically impossible to
directly measure the secondary-winding impedance. Moreover, its magnitude is usually very low
( ≤ 1𝑚Ω ) and it is difficult to measure accurately and consistently for meaningful results.
Therefore, the transformer’s impedance is measured from the primary side for a two-fold benefit
– (a) the impedance can easily be measured across the two distinct primary winding terminals, and
(b) it is easier to capture any small differences in secondary impedance, because the high turns
ratio will reflect the small resistances of the secondary to the primary with a large gain.
However, to validate the measurement, the entire transformer must be modeled, which would
include the magnetizing inductance and the winding leakage inductances. Fig. 2.11 shows the
complete schematic for one elemental transformer, and Fig. 2.12 shows the equivalent circuit
29
Fig. 2.11. Schematic of one elemental transformer with CT rectifiers and loop parasitics.
where 𝑍1 , 𝑍2 , 𝑍3 and 𝑍4 are the branch impedances shown in Fig. 2.12 and are defined as:
𝑍1 = 𝑅𝑚 + 𝑗𝜔 𝐿𝑚 , (2.19)
𝑍2 = 𝑛2 (𝑅𝑤 + 𝑗𝜔 𝐿𝑤 ), (2.20)
1
𝑍3 = 𝑛2 (𝐸𝑆𝑅 + ) , 𝑎𝑛𝑑 (2.21)
𝑗𝜔 𝐶𝑡𝑜𝑝
1
𝑍4 = 𝑛2 (𝐸𝑆𝑅 + 𝑅𝑠 + 𝑗𝜔𝐿𝑠 + ). (2.22)
𝑗𝜔 𝐶𝑏𝑜𝑡
30
Modeling the transformer also introduces magnetizing and leakage inductance branches into
the model, and these must be accounted for to fully validate the measurement. A list of different
tests to accurately measure or model the different elements in Fig. 2.12 is provided below. The
transformer impedance is measured using a Keysight 4990A impedance analyzer with the
3.1 [A8][A9]𝐿𝑚 and 𝑅𝑚 : The magnetizing impedance branch 𝑍1 can be measured by setting the
secondary side to be an open circuit (OC), as shown in Fig. 2.13 (a), resulting in the
(a) (b)
(c)
Fig. 2.13. Magnetizing inductance measurement: (a) open-circuit secondary, (b) equivalent
circuit model, and (c) impedance and resistance measurement results.
31
The equivalent circuit model is modified as shown in Fig. 2.13 (b), resulting in the Z being
measured as:
𝑍 = 𝑍1 . (2.23)
From the measurement curves in Fig. 2.13 (c), the impedance curve is purely inductive up
to 1 MHz, and the magnetizing inductance can be calculated from the slope. The
magnetizing resistance is a representation of the core loss and is obtained directly from the
3.2 [A10]𝐿𝑘 and 𝑅𝑤 : The leakage impedance branch 𝑍2 can be measured by setting one half of
the secondary side to be a short circuit (SC) as shown in Fig. 2.14 (a), resulting in the
(a) (b)
(c)
Fig. 2.14. Leakage inductance measurement: (a) short-circuit secondary, (b) equivalent circuit
model, and (c) impedance and resistance measurement results.
32
The equivalent circuit model is modified as shown in Fig. 2.14 (b), resulting in the Z being
measured as:
𝑍 = 𝑍1 ||𝑍2 ≈ 𝑍2 𝑎𝑠 𝑍1 ≫ 𝑍2 . (2.24)
From the measurement curves in Fig. 2.13 (c), the leakage inductance can be calculated
from the slope of the impedance curve. The magnetizing resistance is a representation of
the winding loss and is obtained directly from the measurement (green curve in Fig.
2.14(c)).
3.3 Capacitance[A11] measurement: The capacitance and the ESR of the ceramic capacitors are
measured using the 16034E test fixture for surface-mounted devices (SMDs) attached to
the Keysight 4990A, as shown in Fig. 2.15 (a). The impedance measurement results for
one sample, a 25V 4.7µF X8L 0805, is shown in Fig. 2.15 (b).
(a) (b)
Fig. 2.15. (a) 16034E probe with device under test (DUT), and (b) capacitor parameter
measurement.
Three capacitors with low ESRs were tested for this study, and their results are summarized
in Table 2.1.
33
Table 2.1. Summary of selected capacitors.
inductance and resistance of the termination due to their small magnitudes. Therefore,
FEA Q3D simulations are performed to simulate the termination-loop inductance 𝐿𝑠 and
Fig. 2.16.
The AC 𝐿𝑘 and 𝑅𝑘 vary with frequency, and since the exact parallel resonant frequency is
not known beforehand, the exact values for the AC 𝐿𝑘 and 𝑅𝑘 cannot be selected.
Therefore, an average over a realistic frequency range is taken, which in this case is
selected as 0.5 MHz – 1.5 MHz, and results in the following values:
34
Once all the parameters are accounted for, the hardware measurement can be successfully
validated by the transformer model. Instead of the impedance, the transformer resistance is studied
because it provides a direct relationship with the transformer loss, which ultimately determines the
converter’s efficiency.
The transformer resistance was measured with the three capacitors listed in Table 2.1 mounted
as the output filter capacitors. Fig. 2.17 shows the measured transformer resistances with the three
capacitors as solid lines, and the modeled curves as the dashed lines.
Fig. 2.17. Measured and modeled equivalent transformer resistance versus frequency.
• The model agrees well with the measurements within reasonable margin of measurement error.
• The resistance curves can be seen to have two peaks: one at a low frequency corresponding to
the parallel resonance involving the magnetizing inductance branch, and the other at a higher
35
• As the capacitance increases, the parallel resonant frequency and the peak resistance at the
• The parallel resonant frequency of the parasitic loop should be kept far away from the
converter’s switching frequency to minimize the transformer resistance, and hence transformer
loss increase. For example, when operating at 1 MHz, the measured transformer resistances
for the 10µF, 4.7µF and 1µF capacitors are 642 mΩ, 1.41 Ω and 714 mΩ, respectively. This
shows that at 1 MHz, simply by changing the output capacitance from 10 µF to 4.7 µF, the
transformer resistance, and hence the winding loss, will increase by almost 100%, which is
significant.
These results provide a general design guideline for output filter capacitor selection for planar
transformers with center-tapped rectifiers, so as to minimize the impact of the parasitic parallel
2.5 Conclusions
In this chapter, the termination design in planar matrix transformers with center-tapped
rectifiers have been studied. Advances in termination design have been reviewed, including
minimization of the termination loss by moving the secondary layers to the top and bottom PCB
layers such that the SRs and output filter capacitors can be placed directly on them.
However, this solution involves splitting the output filter capacitance between the top and
bottom layers, which results in a long parasitic path between them with significant parasitic
inductance. This inductance resonates with the parallel branch containing the filter capacitors,
36
The parallel resonant frequency is dependent on the parasitic inductance and the filter
capacitance. In this study, the impact of filter capacitance on the parallel resonant frequency is
resistance with different output capacitors. However, the entire transformer is modeled since the
impedance must be measured from the primary side. The model verifies the measurement within
experimental tolerance, and verifies the hypothesis that the transformer resistance, and hence
transformer conduction losses, are highest if the switching frequency is at the parallel resonant
frequency; hence the latter must be moved far away from the former for optimal efficiency. For
example, at 1MHz operation, either the 10µF or the 1µF capacitor may be used, but the parallel
resonant peak with the 4.7µF capacitors is right around 1 MHz, resulting in almost double the
transformer resistance.
The future scope for this work includes investigating the termination parasitic loop in detail
and attempting to minimize the loop inductance in order to push the parallel resonant frequency
further up the frequency, thereby reducing the impact of the capacitance selection on the
converter’s performance.
37
Chapter 3. Improved Symmetrical Shielding Technique
3.1 Introduction
The planar matrix transformer with PCB windings for resonant converters has been
demonstrated to exhibit high efficiencies and high power densities, while realizing high
reproducibility and the ability to be mass-produced. However, the large cross-sectional area of the
transformer results in significant overlapping and limited distance between the primary and
secondary windings, resulting in large inter-winding parasitic capacitances between the primary
(a)
(b)
Fig. 3.1. (a) Schematic of LLC converter with switching nodes, and (b) CM noise sources and
coupling paths.
38
There are four voltage pulsation nodes in the converter with high 𝑑𝑣/𝑑𝑡 – the half-bridge
switching node 𝑉𝑆𝑊 , the voltage applied to the transformer primary winding 𝑉𝑝𝑟𝑖 and the drain-
source voltages of the two SRs, 𝑉𝑆𝑅1 and 𝑉𝑆𝑅2, as shown in Fig. 3.1 (a). Fig. 3.1 (b) shows the
simplified CM noise coupling path with the lumped switching voltages. 𝑉𝑆𝑅1 and 𝑉𝑆𝑅2 are equal in
magnitude and opposite in phase, and hence cancel out each other’s CM noise. Another path for
the CM noise coupling is from 𝑉𝑆𝑊 to the primary ground through another parasitic capacitance
𝐶𝐴𝐺 . However, 𝐶𝐴𝐺 is generally much lower in magnitude than 𝐶𝑃𝑆 and hence 𝑉𝑝𝑟𝑖 dominates the
CM noise going through the transformer, since it has a path through the large inter-winding
capacitors.
𝑑𝑉𝑃𝑟𝑖
𝑖 = 𝐶𝑃𝑆 . (3.1)
𝑑𝑡
To mitigate the CM noise through 𝐶𝑃𝑆 , either the 𝑑𝑉𝑃𝑟𝑖 /𝑑𝑡 can be reduced, or the propagation
path capacitance 𝐶𝑃𝑆 can be minimized or eliminated. To achieve this, the shielding technique is
commonly employed [29][30]. The idea is to introduce additional PCB layers to the transformer
between the primary and secondary layers, which can conduct the CM noise current back to the
primary side.
Fig. 3.2 shows the schematic and the modified PCB layer stack-up of the previously four-
layer PCB planar matrix transformer with shielding. One shield layer is added between each set of
39
(a) (b)
Fig. 3.2. (a) LLC converter schematic, and (b) six-layer PCB stack-up.
The shield layers are placed between the primary and secondary layers and are connected to
the primary ground such that the induced CM noise from the primary is blocked by the shield and
conducted back into the primary ground, thereby isolating the secondary side. However, the
induced voltage in the shield windings act as another voltage pulse source, and hence can further
(a) (b)
Fig. 3.3. Equipotential shield windings: (a) shield and secondary windings, and (b) potential
mapping across the windings.
40
The shield winding must be designed identical to the secondary winding, such that there is no
potential difference between the two, and hence no current flow. Fig. 3.3 illustrates this concept,
as the one-turn shield layer is identical to the one-turn secondary layer. The winding can be
expanded along the x-axis, along which the voltage potential can be mapped. Terminal B of the
secondary winding is connected to the secondary ground. Hence, the potential from A to B reduces
from an arbitrary V to 0. To make the shield winding identical, the B’ terminal of the shield is
connected to the primary ground, since the induced CM noise current must be sent back to the
primary side. Due to the identical structures of the two windings, the potential at terminal A’ is
also V. Since the voltage potential at each point on the two layers is identical, there is no CM noise
current going from the shield to the secondary. Moreover, the two windings remain at equipotential
even if the shield winding is rotated about its center by an arbitrary angle [29].
However, there are now two additional layers that conduct current in the planar transformer,
leading to additional losses, and hence lower efficiency. Since the induced current is low in
magnitude, typically low-weight copper is used to design the shield layers to minimize the induced
eddy currents that increase with copper weight. However, CPES recently proposed a modified
shielding technique that utilizes part of the shield windings as part of the primary windings to
Fig. 3.4 shows the proposed shielding technique as part of the primary. Half the shield
windings are connected in parallel, as they have the same voltage potential at the terminals. Next,
the primary windings’ terminal connected to the primary ground is disconnected and is instead
41
Fig. 3.4. Modified shielding technique with shielding as part of the primary.
It can be observed that, in addition to the 16 primary turns, four shield windings also carry
one-fourth of the primary current, which is equivalent to an additional primary turn. This results
in a net turns ratio of 17:1, which results in a lower primary current – and hence lower primary
device conduction loss – by around 10%. Therefore, the increase in transformer loss due to the
addition of the shield layers can be offset by the reduction in primary device conduction loss,
The winding structure for the proposed shielding is shown in Fig. 3.5. The primary current
exits the primary layers and enters the Layer 2 shield, upon which it splits into the four matrix
transformers and conducts on windings alternating between the two shield layers for better
interleaving and current sharing. Finally, the primary current merges in the Layer 5 shield and
42
(b) (c)
(a)
(d) (e)
Fig. 3.5. PCB winding arrangement for proposed shielding: (a) transformer schematic with
proposed shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4: primary, and (e)
Layer 5: shielding.
This technique was incorporated into the existing 800W 400V/12V LLC converter running at
1 MHz. The hardware prototype is shown in Fig. 3.6. The measured CM noise and the converter’s
efficiency compared with that of the converter without shielding is shown in Fig. 3.7 (a) and Fig.
43
Fig. 3.6. Hardware prototype of 400V/12V LLC with proposed shielding.
(a) (b)
Fig. 3.7. Hardware testing results of 400V/12V LLC with proposed shielding: (a) CM noise
comparison, and (b) converter efficiency comparison.
The CM noise was reduced significantly – by up to 30 dBµV – with the proposed shielding.
Moreover, instead of sacrificing efficiency, it improved the peak efficiency from 97.6% to 97.7%
and the full-load efficiency from 97.2% to 97.4% due to the lower primary device conduction
While this work has substantial significance, a few aspects of the modified shield structure
were not studied. This chapter will investigate the impact the modified shielding has on other
aspects of the converter performance, such as current sharing and leakage-inductance symmetry,
44
3.2 Current-Sharing Study in Matrix Transformers
Due to the presence of multiple output sets in parallel in the matrix transformer, it is crucial to
maintain good current sharing among them, failing which can result in lower efficiencies,
especially at heavier loads. Therefore, improving current sharing between the parallel output sets
(connecting wires) from the output of the transformer to the load for all output sets, the internal
transformer structure should also be investigated for any potential impedance imbalances, which
One way to study current sharing in the matrix transformer is to study the thermal performance
of the different elemental transformers, as an output carrying higher current would be hotter.
However, this would be a suitable method only in ideal conditions, such as with no external cooling
elemental transformer in the converter has different components in its vicinity, which means the
heat dissipated from neighboring components could affect the temperatures of the elemental
transformers. This requires a comprehensive study of the thermal resistance network for each
elemental transformer and calibration of their temperatures, which is beyond the scope of this work.
A more accurate method of studying the current sharing is to directly measure the secondary
current flowing out of each elemental transformer, but this is not a practical approach.
Alternatively, the drain-source voltages (𝑉𝐷𝑆 ) of the SRs can be measured to get an accurate
representation of the current flowing through them. Fig. 3.8 shows waveforms of interest on the
45
Fig. 3.8. Waveforms of interest on the secondary side during one-half of a cycle of operation.
Fig. 3.8 plots the primary gate-source voltage (𝑉𝐺𝑆 ), the transformer secondary-side voltage
(𝑉𝑡𝑟𝑎𝑛𝑠 ), the SR drain-source voltage (𝑉𝐷𝑆,𝑆𝑅 ), the SR source-drain current (𝐼𝑆𝐷,𝑆𝑅 ), and the SR
gate-source voltage (𝑉𝐺𝑆,𝑆𝑅 ) from top to bottom. The state of the converter at different times after
𝑡0 : The 𝑉𝐷𝑆 of the SR reaches 0 and it starts conducting through its body diode to reduce the
𝑡2 : The SR channel is turned off just before the current’s zero-crossing. The remaining current
conducts through the body diode, again reducing the 𝑉𝐷𝑆 of the SR to −𝑉𝑓 .
𝑡3 : The SR current goes to 0 and the body diode of the SR stops conducting. The 𝐶𝑜𝑠𝑠 of the
SR starts charging.
46
By sufficiently delaying the SRs’ turn-off instants, their drain-source voltages can be
measured, and the period between 𝑡2 and 𝑡3 can be analyzed to obtain the relative quantity of
Fig, 3.9 (a) and Fig. 3.9 (b) show the measured drain-source voltages of the SRs during the
turn-off instances of the two half-cycles of operation at full loads. Fig. 3.9 (c) shows the positions
of the SRs in the two secondary layers. On the top secondary layer, SR3 and SR7 operate in the
first half-cycle SRA, whereas SR2 and SR6 operate in the second half-cycle SRB. On the bottom
secondary layer, SR1 and SR5 operate in the first half-cycle SRA, whereas SR4 and SR8 operate
[A13]
(a)
(b) (c)
Fig. 3.9. 𝑉𝐷𝑆 waveforms of SRs during the turn-off instant: (a) first half-cycle, (b) second half-
cycle, and (c) SR positions on the transformer.
47
Two observations can be made from Fig. 3.9 – (a) the body diode conduction periods in the
two half-cycles are asymmetrical, with ~110 ns and ~95 ns for the first and second half-cycle,
respectively, for the top-side SRs, and (b) the body diodes of the SRs in the bottom layer (closer
to the air gap) stop conducting before those in the top layer (away from the air gap). These issues
The explanation for the asymmetrical body-diode conduction periods in the two half-cycles
can be traced to the shielding design. From Fig. 3.5 (c), Fig. 3.5 (e) and Fig. 3.9 (c), it can be
observed that only one shielding layer in each leg conducts during both half-cycles[A14]. However, the
conducting SR, and hence the conducting secondary layer, alternates between the top and bottom
layers during one switching cycle. This leads to different proximities of the conducting shield layer
[A15]
(a) (b)
Fig. 3.10. Conducting layer proximities with the original shielding technique: (a) first half-cycle,
and (b) second half-cycle.
The arrows indicate the proximities between the shield and secondary layers. The dotted lines
represent the non-conducting layers, and the solid lines represent the conducting layers. To verify
48
this, 3D FEA simulations were performed, and the leakage inductances of the conducting
Fig. 3.11. 3D FEA simulated leakage inductances of secondary windings with original shielding.
It can be clearly observed that the leakage inductances are asymmetrical in the two half-cycles.
This leads to different resonant periods in the two half-cycles, resulting in different secondary
currents, which was reflected by the different body-diode conduction periods in the two half-cycles
The intuitive solution for this issue is to parallel the two shield windings in each elemental
transformer, such that the proximities between the conducting shield layer and the conducting
secondary layer are the same in both half-cycles, as shown in Fig. 3.12.
[A16]
(a) (b)
Fig. 3.12. Conducting layer proximities with the modified shielding technique: (a) first half-
cycle, and (b) second half-cycle.
49
It can be observed that when both shield windings conduct, the proximities are symmetrical
in the two half-cycles. This is verified by the 3D FEA simulations performed on the modified
transformer to calculate the leakage inductances of the conducting secondary windings in the two
Fig. 3.13. 3D FEA simulated leakage inductances of secondary windings with modified
shielding.
Fig. 3.14 shows the modified shield-winding PCB design with all the shield windings
paralleled. The primary current exits the primary windings through the black spot and enters the
Layer 2 shield winding, after which it symmetrically splits into all eight shield windings (four on
Layer 2 and four on Layer 5 through the blue vias). Finally, the split currents converge back
through the black vias in Layer 5 and drain into the primary ground.
However, when the shield windings of this improved design are simulated on FEA 3D, the
current densities are much higher than the original shield windings, as shown in the comparison in
Fig. 3.15. Moreover, the current directions in the paralleled shield windings are anti-parallel,
indicating circulating current in the shield windings. This results in a 190% increase in the shield
50
(b) (c)
(a)
(d) (e)
Fig. 3.14. PCB winding arrangement for improved shielding: (a) transformer schematic with
improved shielding, (b) Layer 2: shielding, (d) Layer 4: primary, and (e) Layer 5: shielding.
51
(a) (b)
(c) (d)
Fig. 3.15. 3D FEA simulated current density comparison between original and improved shield:
(a) Layer 2 shield in original shielding, (b) Layer 5 shield in original shielding, (c) Layer 2 shield
in improved shielding, and (d) Layer 5 shield in improved shielding.
(a) Layer 2 shield in improved shielding (b) Layer 5 shield in improved shielding
Fig. 3.16. Current directions in the paralleled shield windings in the improved shielding:
(a) Layer 2 shield, and (b) Layer 5 shield.
52
To understand the reason for the circulating current, the electric field distribution within the
[A17]
Fig. 3.17. Electric field distribution within the layers of a PCB transformer with CT rectifiers.
As discussed in Section 2.1, for transformers with CT rectifiers on the secondary side, the
planar transformer design that has the secondary windings on the top and bottom layers is better
in terms of termination loss. However, it has worse interleaving with the primary windings, as can
be seen from the 2D FEA simulated electric field distribution in between the PCB windings of the
planar transformer during one half-cycle. Since only one secondary layer conducts in each half-
cycle, the electric field distribution is asymmetrical within the transformer. The shield layer closer
to the conducting secondary generates eddy currents to cancel the magnetic fields from both
secondary and primary windings between which it is placed. However, the other shield layer,
which is placed between the primary windings and the non-conducting secondary winding, only
induces eddy currents from the magnetic field of the primary windings. Thus, circulating current
is induced to reduce the leakage energy difference between the two shield layers, resulting in the
53
The solution for this is to expose both shield windings to equal electric fields within the
transformer. To achieve this, the litz-wire concept of interleaving is implemented in the PCB
windings. Fig. 3.18 shows the modified shield-winding arrangement, where the two parallel shield
windings are interwound such that the equivalent electric field is homogeneous around both shield
(a) (b)
Fig. 3.18. Interwound parallel shield layers to homogenize the electric field around them: (a)
cross-section view, and (b) current flow in 3D view.
As can be observed, by employing vias, the two shield windings can be interleaved such that
the equivalent electric fields around both shield layers are symmetrical. After this modification,
the 3D FEA simulation yields normal current densities in the shield windings, as shown in Fig.
3.19. The shield winding loss is 0.6 W, which is 8% lower than the original shield winding due to
54
(a) (b)
Fig. 3.19. Current density in the paralleled shield windings with interleaved shielding:
(a) Layer 2 shield, and (b) Layer 5 shield.
(b) (c)
(a)
(d) (e)
Fig. 3.20. PCB winding arrangement for improved and interleaved shielding: (a) transformer
schematic with improved shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4:
primary, and (e) Layer 5: shielding.
55
Fig. 3.20 shows the final PCB winding arrangement of the improved and interleaved shield
windings. The green vias on the four corners of the matrix transformer are used to interleave the
two shield windings. Although they make holes to pass through the primary windings, which are
sandwiched between the two shield windings, the current densities on the winding corners are
From Fig. 3.9, it can be observed that the body-diode conduction periods of SRs that are placed
on the bottom layer are lower than those placed on the top layer. This is because of the different
proximities of the two secondary layers to the transformer’s airgap. Fig. 3.21 (a) shows the cross-
section of the construction of a typical planar transformer; as shown, the airgap is situated just
outside the PCB, hence making it closer to one of the secondary layers.
The leakage inductance paths for the two secondary layers on the top and bottom layers are
shown in the transformer cross-sectional view in Fig. 3.21 (a) [32]. For the secondary winding in
the top layer, the reluctance of the leakage path is ℛ𝑐𝑜𝑟𝑒 , whereas that for the secondary winding
in the bottom layer is ℛ′𝑐𝑜𝑟𝑒 + 2ℛ𝑎𝑖𝑟 . Since air has a much high reluctance than the ferrite core,
the leakage path for the secondary layer close to the airgap has higher reluctance, and lower
leakage inductance than the secondary layer away from the airgap.- Therefore, as can be seen in
Fig. 3.21 (b), the higher leakage inductances of the secondary (also seen in the 3D FEA simulations
in Fig. 3.11) result in a lower body-diode conduction period as compared to the SRs on the top
secondary layer (Fig. 3.9), and this causes some current-sharing issues.
56
[A18]
(a) (b)
Fig. 3.21. Asymmetrical leakage inductance and current sharing with airgap on one end of
transformer: (a) leakage inductance path for secondary, and (b) 𝑉𝐷𝑆 of SRs during turn-off.
To achieve better symmetry, the airgap can be moved to the middle of the transformer leg, as
shown in Fig. 3.22 (a). By doing so, the reluctance of the leakage paths – and hence the leakage
inductance – will be more symmetrical for the top and bottom secondary layers. This results in a
significantly lower difference in the body-diode conduction periods between the SRs on the top
(a) (b)
Fig. 3.22. Symmetrical fringing flux and current sharing with airgap in the middle of
transformer: (a) fringing flux with airgap in the middle, and (b) 𝑉𝐷𝑆 of SRs during turn-off.
However, moving the airgap to the middle also exposes the other PCB layers to the fringing
flux of the airgap, thereby inducing eddy currents in them, too [33]. Since the eddy current loss is
independent of load, this results in a reduction in the light-load efficiencies when a hardware
57
prototype of the 800W 400V/12V LLC converter running at 600 kHz was tested with the airgap
[A19]
Fig. 3.23. Efficiency reduction when moving the airgap to the middle.
One solution for mitigating the eddy current induction in the PCB layers that occurs due to
the fringing flux of the airgap is to increase the clearance between the transformer core and the
PCB windings. However, while maintaining the same transformer footprint, doing so will reduce
the winding width correspondingly. At light and medium loads, the eddy current losses contribute
a significant percentage of the transformer loss, and hence the clearance between the transformer
core and PCB windings can be optimized to minimize the transformer loss. However, at higher
loads, the percentage of the winding losses are so high that any reduction in fringing losses from
increasing the clearance is overshadowed by the increase in winding loss due to lower winding
widths.
To verify the current-sharing improvement with the symmetrical shielding structure over the
previous asymmetrical shielding, a 400V/12V LLC converter was built with the improved
58
shielding technique, and the converter efficiency was compared with the previous shielding
technique, as shown in Fig. 3.24. The converters were operated at 600 kHz.
[A20]
It can be observed that, with the better current sharing that happens with improved
symmetrical shielding, the conduction losses are lower, resulting in an improvement in full-load
efficiency by up to 0.25%, which represents a converter loss that is around 2W lower. This result
exhibits the importance of having good current sharing between the different elemental
Fig. 3.25 shows the measured CM noise spectrum of the LLC converter with improved
shielding, as compared to that with previous shielding and no shielding. As the fundamental
shielding concept remains the same in the two shielding techniques, a CM noise reduction of
around 25 dBµV over most of the frequency spectrum up to 20 MHz can be achieved over the
converter with no shielding. This exhibits that, with similar shielding performance, the
symmetrical shielding can achieve higher converter efficiencies over the previous asymmetrical
counterpart.
59
Fig. 3.25. CM Noise measurement spectra.
3.6 Conclusions
This chapter has discussed the requirement for shielding in planar matrix transformers, and
reviewed the existing techniques of shielding, the most effective being one where half the shield
windings double as primary windings to increase the effective turns ratio by 1, thereby improving
efficiency.
Next, the current sharing in the matrix transformer was studied by examining the 𝑉𝐷𝑆 of the
SRs during the turn-off period. Different leakage inductances of the secondary windings in the two
This challenge was traced to the asymmetrical shielding structure, where the same shield layer
conducts in both half-cycles, which results in different proximities to the conducting secondary
windings.
This issue was addressed by paralleling the two shield windings. However, due to imperfect
interleaving in the center-tapped rectifiers, the two shield layers are exposed to different electric
60
fields in the transformer, resulting in current circulating among them. To overcome this, the litz-
wire concept was implemented on PCB windings; in this approach, the two shield layers are
interleaved and paralleled, resulting in them being exposed to the same electric field. The modified
shielding structure was shown to have symmetrical leakage inductances in the two half-cycles of
Moreover, the location of the transformer airgap also affects current sharing in planar
transformers. Typically, the airgap is placed on one end of the PCB windings. However, this
approach results in an induction of eddy currents in the secondary layer closer to the airgap, in
which causes a higher leakage inductance to occur than on the secondary layer away from the
airgap. To address this, the airgap can be moved to the middle of the PCB such that both secondary
layers are exposed to equal fringing flux, resulting in symmetrical leakage inductances. However,
this also means eddy currents will be induced in the other PCB layers due to their proximity to the
airgap. This affect can be reduced by increasing the clearance between the windings and the core
leg, at a cost of lower heavy-load efficiencies due to lower winding widths at the same transformer
footprint.
prototype was developed, which could achieve up to 0.25% higher efficiency at full-load as
compared to the converter with the previous asymmetrical shielding. Moreover, both shielding
techniques achieve similar reduction in CM noise as compared to the converter with no shielding.
61
Chapter 4. Resonant Frequency Optimization of LLC
Converters
4.1 Introduction
As discussed in the introduction, the motivation for this thesis is to further improve the
performance of the previous CPES 400V/12V LLC converter in order to keep pace with the
performance levels of the latest technologies and with the ever-increasing demand for datacenters.
In the previous chapters, different aspects of converter performance were studied to improve the
converter’s efficiency, including termination design optimization and a design that achieves
improved current-sharing with symmetrical shielding. This chapter will address another aspect of
For LLC converters, such as this one, operating as unregulated DC-DC transformers, the
converter switches exclusively at the resonant frequency, at which point the converter efficiency
is at its maximum. In all the previous work that CPES did on the 400V/12V LLC converter, the
switching frequency was fixed to 1 MHz in order to exhibit the high-frequency operability and
However, the various losses in the converter, such as the device losses and the transformer
losses, are highly dependent on the switching frequency. As shown in Fig. 4.1, the device turn-off
loss, the gate driving loss and the conduction losses all increase with frequency. Moreover, the
transformer’s winding losses also increase with frequency, since the winding AC resistance and
the winding currents increase with frequency [34]. However, the transformer’s core loss decreases
with increasing frequency, as Fig. 4.1 shows in the core loss of the ML-91s material at fixed
62
voltage excitation. Lower core losses at higher frequencies allow the transformer size to be shrunk,
[A21] [A22]
Fig. 4.1. Converter losses that increase with switching frequency: (a) device switching loss, (b)
device conduction loss, and (c) transformer winding loss.
There is clearly a tradeoff between the different losses in the converter with changes in
frequency. Moreover, for low-voltage, high-current applications such as this one, the losses that
increase with frequency (conduction losses) outweigh the one that decreases with frequency (core
loss), as seen in the converter loss breakdown at 1 MHz in Fig. 4.3. The red bars show the losses
that increase with switching frequency and the blue bar shows the loss that decreases with
switching frequency. Clearly, for such applications, the switching frequency must be optimized to
maximize the efficiency, while also studying the impact on power density.
63
[A23]
In this chapter, the switching frequency for the 400V/12V LLC converter is optimized. Core
loss densities of different ferrite materials are evaluated, and a material selection guideline is
provided. Finally, the converter’s loss and power density are evaluated at different frequencies,
and the optimal frequency is selected. The performance improvement is showcased with hardware
Fig. 4.4 shows the flowchart for optimizing the switching frequency of the LLC converter.
[A24]
64
The first step is to select the best ferrite material at the selected switching frequency. Typically,
Mn-Zn ferrite materials are used to design the transformer cores in high-frequency applications
[35]. Companies design using different materials, which are then recommended to be operated at
a specific frequency range for optimal performance. Among those, the ferrite material with the
lowest core loss density is typically selected for the transformer design. The core loss density 𝑃𝑣
𝛽
𝑃𝑣 = 𝑘 ∙ 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠𝛼 , (4.1)
where 𝐵𝑚𝑎𝑥 is the peak magnetic flux density in the core, 𝑓𝑠 is the switching frequency, and 𝛼, 𝛽,
and 𝑘 are the Steinmetz coefficients that are uniquely defined for each material. Moreover, 𝐵𝑚𝑎𝑥
𝑇𝑠
∫02 𝑣0 𝑑𝑡 𝑉𝑜 (4.2)
𝐵𝑚𝑎𝑥 = = ,
2 𝑛 𝐴𝑒 4 𝐴𝑒 𝑓𝑠
where 𝑣0 is the instantaneous output voltage, 𝑛 is the turns ratio, 𝐴𝑒 is the cross-sectional area of
𝑉𝑜 𝛽 𝛼−𝛽
𝑃𝑣 = 𝑘 ∙ ( ) ∙ 𝑓𝑠 . (4.3)
4𝐴𝑒
Generally, 𝛽 > 𝛼 for ferrite materials, which results in a reduction in core loss density with
increases in frequency. Also, 𝛼 − 𝛽 determines the degree to which the core loss density decreases
65
The materials datasheets typically provide average Steinmetz coefficients for different
frequency ranges, but this results in some unanswered questions, leading to the motivation to
To demonstrate this, the 3F3 material from Ferroxcube can be used as an example. Table 4.1
shows the Steinmetz coefficients provided in its datasheet, where different coefficients are
It can be observed that from 200 kHz – 400 kHz, 𝑃𝑣 ∝ 𝑓𝑠−0.6 , which means increasing the
frequency within this range will be beneficial toward reducing the core loss density. Moreover,
from 400 kHz – 700 kHz, 𝑃𝑣 ∝ 𝑓𝑠−0.03 , which means that in this frequency range, increasing the
frequency has negligible impact on the core loss density, hence negating any benefits of doing so.
However, from the average Steinmetz coefficients provided in the datasheets, it is impossible to
pinpoint the exact frequency at which frequency will stop impacting core loss density.
Another discrepancy can be observed from the Steinmetz coefficients provided in the
datasheet for ML-91s from Hitachi metals. Table 4.2 shows different coefficients provided for
66
The 𝑃𝑣 calculated at 1 MHz (and 𝐵𝑚𝑎𝑥 = 80𝑚𝑇, a typical design point) using the first and
second sets of coefficients results in 𝑃𝑣 = 714 𝑘𝑊/𝑚3 and 𝑃𝑣 = 441 𝑘𝑊/𝑚3 , respectively, a
significantly large 62% difference. Therefore, it is difficult to determine the exact core loss density
These reasons led to the requirement to experimentally measure the core loss densities of
various materials to accurately characterize them at different frequencies. Different Mn-Zn ferrite
materials with low core loss densities (according to their datasheets) are selected for testing, as
Table 4.3. Mn-Zn ferrite materials selected for core loss testing.
The core loss densities are measured using toroidal cores, such that there is uniform magnetic
flux throughout the core. The two-winding method with capacitive cancelation and partial
The core loss densities of all the materials are measured at room temperature at different 𝐵𝑚𝑎𝑥
and at different 𝑓𝑠 , resulting in numerous curves. To make the characterization and comparison
significantly simpler and more straightforward, the performance factors of different materials are
evaluated [38][39]. The physical significance of this parameter can be understood from the
following equations:
67
𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠 𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠
𝑃𝑣 = = , (4.4)
𝑉𝑜𝑙𝑢𝑚𝑒 𝐴𝑒 ∙ 𝑙
where 𝑙 is the mean path length for the magnetic flux. 𝐴𝑒 can then be expressed as:
𝑉𝑜
𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 = . (4.6)
4 𝐴𝑒
𝑉𝑜 ∙ 𝑃𝑣 ∙ 𝑙 1
𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 = . (4.7)
4 𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠
The term on the LHS can be defined as the performance factor, ℱ, as:
ℱ = 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 . (4.8)
It can be observed from (4.7) that for a fixed core loss density and effective path length (core
size), a material with higher performance factor will result in a lower core loss while achieving the
Based on this, the performance factors of the different materials were calculated and plotted
against the switching frequency at a fixed 𝑃𝑣 = 0.5𝑊/𝑐𝑚3 , which is the typically observed value
68
Fig. 4.5. Performance factors of ferrite materials at 𝑃𝑣 = 0.5𝑊/𝑐𝑚3 .
The frequencies for the different materials were pushed until the performance factor curves
started plateauing, as can be seen in the curves for ML27D and ML91s in Fig. 4.5. The frequency
was swept from 100 kHz – 2 MHz and the eight listed materials were tested in the relevant
frequency ranges. Based on the performance factor curves, the materials with the highest
performance factors at each frequency can be traced as shown by the yellow dotted line in Fig. 4.5
It may be noted that the ferrite materials from Hitachi Metals perform significantly better
69
To generalize this study to other applications with different core loss densities, the
performance factors at 𝑃𝑣 = 0.3𝑊/𝑐𝑚3 and 𝑃𝑣 = 0.7𝑊/𝑐𝑚3 were also calculated and plotted
(a) (b)
0.3𝑊
Fig. 4.6. Performance factor comparison at different core loss densities: (a) 𝑃𝑣 = , and (b)
𝑐𝑚3
𝑃𝑣 = 0.7𝑊/𝑐𝑚3 .
It can be observed that, even within a wide range of core loss densities, the relative
performance factors of the materials are largely similar. This means that for other applications with
different core loss densities, the results from this study can be used as a design guideline for
Once the best-performing ferrite materials have been chosen, the converter loss is calculated
at different frequencies. The switching frequency is swept from 200 kHz – 1.6 MHz. The loss of
the matrix transformer shown in Fig. 4.7 is calculated using the same method as used in [18], as
summarized below.
70
Since the transformer voltage is rectangular, the core loss expression is modified as given in
[40]:
8 𝛽
𝑃𝑣 = ∙ 𝑘 ∙ 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠𝛼 , 𝑎𝑛𝑑 (4.9)
𝜋2
where the 8/𝜋 2 term is included to account for the rectangular transformer voltage, 𝑃𝑐𝑜𝑟𝑒 is the
𝜌 ∙ 2𝜋 𝑛2 (4.11)
𝑅𝐷𝐶 = ∙ ,
ℎ 𝑙𝑛(𝑐 + 𝑟) − 𝑙𝑛 𝑟
where ℎ is the PCB layer thickness (copper weight), 𝜌 is the resistivity of copper, 𝑛 is the turns
The AC resistance coefficient 𝐹𝑅 is defined by the eddy current model described in [34] as:
(𝑚2 − 1) ′ (4.12)
𝐹𝑅 = 𝑀′ + 𝐷,
3
where 𝑀′ and 𝐷′ are the real parts of 𝑀 and 𝐷 , respectively; and 𝑀 = 𝛼ℎ coth(𝛼ℎ) , 𝐷 =
2𝛼ℎ tanh (𝛼ℎ/2), 𝛼 = √𝑗𝜔𝜇0 𝜂/𝜌, 𝜂 = 𝑁𝑙 𝑎/𝑏, 𝑚 is number of layers in a winding porting, 𝜔 is
angular frequency, ℎ is winding copper thickness, 𝑁𝑙 is the number of turns per layer 𝑎 is the total
winding area width, and 𝑏 is the winding width for each turn. The winding AC resistance can then
be defined as:
71
𝑅𝐴𝐶 = 𝐹𝑅 ∙ 𝑅𝐷𝐶 . (4.13)
From (4.12), it can be noted that the AC resistance is dependent on copper thickness ℎ and
switching frequency 𝜔/2𝜋. The optimal copper thickness is where the winding AC resistance is
at its minimum. Hence, the AC resistances are calculated and plotted as a function of ℎ at different
[A25]
Fabricating PCBs with greater than 3oz Cu is very expensive, and given the diminishing
returns with higher copper weights, 3oz Cu is set as the maximum thickness. For the primary
windings, for 𝑓𝑠 < 1𝑀𝐻𝑧, 3oz Cu is selected as the optimal thickness, and for 𝑓𝑠 ≥ 1𝑀𝐻𝑧, 2oz
Cu is selected as the optimal thickness. For the secondary windings, 3oz Cu is selected as the
2
𝑃𝑤𝑖𝑛𝑑𝑖𝑛𝑔 = 𝑅𝐴𝐶 ∙ 𝐼𝑟𝑚𝑠 , (4.14)
72
The total transformer loss is the sum of the core and winding losses:
[A26]
73
Fig. 4.9 shows transformer loss contours plotted at different core radii and winding widths at
a frequency of 1 MHz. The dotted lines are the transformer’s footprint contours. The knee-point
in each loss contour, shown by the red dot, corresponds to a footprint contour, which is the
minimum footprint required to realize that loss. Hence, at each transformer footprint, the minimum
transformer loss can be achieved solely with a unique 𝑟 and 𝑐 combination (red dot). This also
demonstrates the tradeoff between the core loss and the winding loss, where a higher 𝑟 results in
This process is repeated for different frequencies and the minimum transformer losses can
then be traced out and plotted against the transformer footprint, as shown in Fig. 4.10.
It can be intuitively observed that the transformer loss reduces with as the transformer
footprint grows. However, there are diminishing returns upon increasing the footprint, and the
footprint design point must be chosen at the knee point of the curve for optimal performance.
74
However, since this application is restricted by the quarter-brick form factor, the design region is
chosen around the 1200 mm2 footprint region, which is also around the knee points of the curves.
The optimal 𝑟 and 𝑐 values at 1200 mm2 footprint at various switching frequencies are listed
in Table 4.5.
The core radius to winding width ratio indicates the ratio of the core loss to winding loss in
the transformer. As the frequency increases, the winding loss increases and the core loss decreases,
Finally, the total converter loss for the 1kW 400V/12V LLC converter at different switching
frequencies needs to be evaluated. Fig. 4.11 shows the transformer loss at a footprint of 1200 mm2,
with device loss and total converter loss plotted against the switching frequency of the converter.
75
Fig. 4.11. Different converter losses as a function of resonant frequency.
The different regions show the different ferrite materials used at different frequencies. It must
be noted that the maximum magnetic flux density 𝐵𝑚𝑎𝑥 for the ML91s material was restricted to
80 mT based on its material requirements. The transformer loss increases with frequency with the
same material, as the increase in winding loss is higher than the reduction in core loss. However,
the transformer loss reduces at the frequencies when the core material changes, as switching to a
In addition to the converter loss, the converter power density must also be studied to
completely analyze the impact switching frequency has on the converter’s performance. Since the
transformer, and hence, converter footprint, are fixed at all frequencies, the power density is
dependent on the transformer’s core profile. The plate thickness is calculated such that there is
uniform magnetic field distribution throughout the transformer. Fig. 4.12 shows the magnetic flux
(a) (b)
Fig. 4.12. Magnetic flux density in the transformer: (a) top view, and (b) cross-sectional view.
76
The magnetic flux density in the plates is half of that in the core legs. Therefore, for uniform
𝜙 𝜙/2 (4.17)
= ,
𝐴𝑙𝑒𝑔𝑐𝑜𝑟𝑒 𝐴𝑝𝑙𝑎𝑡𝑒 𝑒𝑓𝑓
where 𝜙 is the magnetic flux density in the core legs, 𝑐 is the cross-section area of the core leg,
and 𝐴𝑝𝑙𝑎𝑡𝑒 𝑒𝑓𝑓 is the effective cross-section area of the plate. Solving (4.17), the required plate
𝜋𝑟 2 (4.18)
ℎ𝑝𝑙𝑎𝑡𝑒 = .
2𝑟 + 𝑐
From Table 4.5, 𝑟 decreases and 𝑐 increases with increases in frequency. This results in a
decrease in plate thickness with increases in frequency, resulting in higher power density with
increases in frequency.
Fig. 4.13 shows the converter’s full-load efficiency versus power density at different
switching frequencies.
[A27]
77
The previous CPES converter’s performance is shown by the yellow dot. The curve behaves
as expected – there is a tradeoff between converter efficiency and power density with changes in
switching frequency. When the frequency is reduced from 400 kHz, there is a diminishing return
in efficiency improvement. Moreover, when the frequency increases from 800 kHz, the efficiency
drops very quickly owing to the high conduction and winding losses at higher frequencies. Hence,
a sweet spot for converter design can be set between 400 kHz and 800 kHz. Based on the design
requirements, either the converter efficiency or the power density can be prioritized, and the
To demonstrate the increase in efficiency compared to the previous CPES converter, a 1kW
400V/12V LLC converter running at 400 kHz was designed. Fig. 4.14 shows the hardware
[A28]
The converter dimensions are 58 mm x 37 mm x 8.1 mm, resulting in a power density of 940
W/in3. This is higher than the previous CPES converter even after operating at lower frequencies
due to the higher rated power. Thermally, it is difficult to push more than 800 W (with air cooling
78
and no heat sinks) at 1 MHz operation due to the high device and transformer temperatures that
occur because of high conduction losses. However, at a lower frequency of 400 kHz, the device’s
conduction losses are much lower, which allows the rated power to be increased, while being
thermally sound.
Table 4.6 shows the specifications of the proposed converter, compared with that of the
The resonant frequency is reduced to 400 kHz as optimized in the previous section. The
leakage inductance, which is used as the resonant inductance, is 478 nH. The resonant capacitance
is then accordingly set such that the resonant frequency equals the switching frequency. The
magnetizing inductance and the dead time are optimized according to the methodology in [15] to
result in 80 µH and 125 ns, respectively. The primary device is replaced with a new GaN device
with lower turn-off energy. Due to lower winding width, the SR is replaced with a BSZ0500NSI,
79
as it has a smaller package that can fit on the winding. Based on the output filter capacitor selection
guideline proposed in Chapter 1, the 10µF capacitors are still the best choice for operation at 400
kHz, and hence are used in this converter. Moreover, based on the study in Chapter 2, the
Fig, 4.15 shows the operating waveforms at light load (10%) and at full load (1kW).
(a)
(b)
Fig. 4.15. 400V/12V LLC converter operating waveforms: (a) light load (10%, 100 W), and (b)
full load (100%, 1 kW).
It can be observed that zero-voltage switching (ZVS) is achieved at both light load and full
load. Moreover, there is no ringing in the secondary VDS voltage due to minimum secondary
leakage.
80
The thermal performance of the LLC converter running at full load (1kW) for around 2
minutes until thermal steady state is shown in Fig. 4.16. The converter is air-cooled with 400 linear
feet per minute (LFM) from left to right. The maximum temperature on the converter is around
94 0C at the primary devices, with the SRs and transformer core showing maximum temperatures
of 91 0C and 53 0C respectively.
Fig. 4.17 shows the measured efficiencies of the converter, compared with that of the previous
CPES converter. Moreover, the dashed efficiency curve shows the calculated efficiency, which
follows the actual measurement closely, hence validating the accuracy of the frequency
optimization model.
81
[A29]
The converter can achieve 95% light-load efficiency (10% load), 98.15% peak efficiency (at
around 500W), and 97.5% at full load (1 kW). Due to better devices and lower switching losses at
lower frequencies, the light-load efficiency increases by 2.4% despite an increase in the core loss.
The peak- and full-load efficiencies also increase by 0.6% and 0.2%, respectively, due to the lower
device conduction and transformer winding losses. This can be quantitatively observed from the
[A30]
82
Therefore, the hardware results verify the performance improvement of the 1kW 400V/12V
LLC converter operating at 400 kHz by illustrating that its efficiency and power density are higher
than the previous CPES 800W 400V/12V LLC converter operating at 1 MHz.
4.5 Conclusions
In this chapter, the resonant frequency, at which the 400V/12V LLC converter switches
exclusively, is optimized to improve the performance over the previous CPES 400V/12V LLC
converter. The different components of the converter loss depend heavily on the switching
frequency, and hence it is vital to optimize it to maximize the performance of the converter.
The selection of the best ferrite material for the transformer core at different frequencies is
vital for minimizing the transformer loss. To achieve this, the core loss densities of different
materials were measured, their performance factors were evaluated at a fixed core loss density as
a function of frequency, and the materials with the highest performance factors were selected. To
generalize the study to other applications with different core loss density values, the relative
performance factors were shown to be similar at different core loss densities, too.
After selecting the core materials, the transformer loss was evaluated at different switching
frequencies. The optimal copper weights for the primary and secondary PCB layers were
calculated. For the primary layers, 3oz Cu is recommended for 𝑓𝑠 < 1𝑀𝐻𝑧 and 2oz Cu is
recommended for 𝑓𝑠 ≥ 1𝑀𝐻𝑧 . For the secondary layers, 3oz Cu is recommended for all
frequencies. The optimal transformer dimensions are selected based on the tradeoff between core
loss and winding loss, and the minimum transformer loss at different transformer footprints are
evaluated, where 1200 mm2 is selected as the design region. Finally, the converter efficiency and
the power densities at different frequencies are evaluated, where there is a tradeoff between the
83
two with changes in frequency. Upon studying the curve, 400 kHz – 800 kHz is recommended as
To demonstrate the efficiency improvement, a 1kW 400V/12V LLC converter running at 400
kHz was built and tested. It is able to achieve 95% and 97.5% efficiencies at a light load and at a
full load, respectively, while achieving a peak efficiency of 98.15%, all of which are higher than
those of the previous CPES converter. Moreover, the power density was 940 W/in3, also higher
than the previous CPES power density, due to the higher-rated power, despite its higher
transformer profile.
also rising exponentially. This is leading to improvements in datacenter power architectures, with
the 400V-bus architecture showing the greatest promise for the future. This, however, requires
stepping down 400 V directly to 12 V on the server motherboard, requiring high efficiency and
power density from the 400V/12V DC-DC converter. CPES has done considerable work in this
field, with the latest converter achieving 97.6% peak efficiency and 900 W/in3. However, extensive
research by other groups is closing the performance gap to the CPES converter, leading to the
motivation of this thesis, which is improving the performance of the previous CPES 400V/12V
LLC converter.
The second chapter studies the termination design of planar matrix transformers with center-
tapped rectifiers. The SRs and output filter capacitors are placed on the secondary windings to
minimize the termination inductance. However, the output filter capacitors are split between the
top and bottom secondary layers, resulting in a long parallel path between the two. This parallel
84
loop has a parasitic inductance that resonates with the capacitance to cause a parallel resonance
peak in the transformer’s impedance curve. This parallel resonant frequency must be kept far away
from the converter resonant frequency to minimize its impact on the transformer’s AC resistance,
and hence, converter efficiency. The chapter proposed a capacitance selection guideline to achieve
this goal.
In addition to selecting a suitable capacitance, the loop inductance value itself can be
minimized by optimizing the termination loop. If the loop inductance is sufficiently small, the
parallel resonant frequency should be high enough to not impact the impedance at the switching
Chapter 3 investigates the shielding technique in planar matrix transformers, which is crucial
for minimizing the high CM noise. CPES previously proposed a shielding technique that uses half
of the shielding turns as part of the primary windings in order to increase the turns ratio by 1,
thereby reducing the primary-device conduction losses to offset the loss increase from adding two
extra layers. However, upon studying the drain-source voltages of the SRs, current-sharing issues
were detected, which were traced to the asymmetrical design of the shield and the position of the
transformer airgap. The shield windings were made symmetrical by conducting all the shield
windings in parallel, and by interleaving the two layers on the same elemental transformer. This
resulted in a 0.25% converter efficiency improvement due to better current sharing in the two half-
cycles of operation.
The transformer airgap location also affects leakage inductance, and hence the current sharing
between the two secondary layers. The airgap can be moved to the center to make the leakage
inductances symmetrical, but this induces eddy currents in the other windings due to their
85
proximity with the airgap, resulting in reduction in light-load efficiency. In the future, other
possible solutions may be investigated to tackle this issue with minimum tradeoffs.
Chapter 4 discusses the switching frequency optimization for the LLC converter. First, the
core loss densities of different materials were measured, their performance factors were evaluated
at a fixed core loss density as a function of frequency, and the materials with the highest
performance factors were selected. Based on this, the converter loss and the power densities were
calculated at different frequencies, where there is a tradeoff between the two with changes in
frequency. Upon studying the curve, 400 kHz – 800 kHz is recommended as the switching
Combining the results from all the chapters, a 1 kW 400V/12V LLC converter operating at
400 kHz with symmetrical shielding and 10 µF output filter capacitors was developed. The
performance of this converter can be updated from Table 1.3, resulting in Table 5.1.
Table 5.1. Updated performance summary of recent 400V/12V unregulated DC-DC converters.
It can be observed that the performance of this work is exemplary as compared to the others
described in this study. The efficiency comparisons with the previous CPES work and other works
86
[A31]
The converter’s power density can be further pushed if the rate power can be further pushed,
while maintaining the same converter dimensions. However, the thermal performance needs to be
further improved to achieve this end, as simply air-cooling is not sufficient to safely run the
87
References
[1] N. Jones, "How to stop data centres from gobbling up the world’s electricity," Nature, vol.
561, 2018, pp.163-166.
[2] A. S. G. Andrae, T. Edler, “On global electricity usage of communication technology: trends
to 2030”, Challenges, Vol. 6, 2015, pp. 117-157.
[3] A. Pratt, P. Kumar, and T. V. Aldridge, “Evaluation of 400 V DC distribution in telco and
data centers to improve energy efficiency,” in Proc. IEEE 29th Int. Telecommun. Energy
Conf., 2007, pp. 32–39.
[5] Vicor white paper, “From 48V direct to Intel VR12.0: Saving ‘Big Data’ $500000 per data
center, per year,” July 2012, [online]:
http://www.vicorpower.com/documents/whitepapers/wp_VR12.pdf.
[6] D. Kim, J. He, and D. G. Figueroa, “48V Power Delivery to Grantley Reference Board,”
2016.
[7] US Energy Information Administraton, “How much electricity does a nuclear power plant
generate?”, Dec. 2020, [online]: https://www.eia.gov/tools/faqs/faq.php?id=104&t=33.
[8] G. AlLee and W. Tschudi. “Edison redux: 380 Vdc brings reliability and efficiency to
sustainable data centers.” IEEE Power and Energy Magazine, vol. 10, no.6, Oct. 2012, pp.
50-59.
[9] S. M. Lisy, B. J. Sonnenberg and J. Dolan. “Case study of deployment of 400V DC power
with 400V/-48VDC conversion,” In Proc. IEEE INTELEC 2014, pp. 1-6.
[10] International Electronics Manufacturing Initiative, “iNEMI Statement of Work (SOW) DC-
DC Power Module, Phase 2,” May 2015 [Online]:
http://thor.inemi.org/webdownload/2015/SOW_DCDC_Power_Module_Phase2_050115.p
df.
88
[11] J. G. Cho, J. A. Sabate, G. Hua, and F. C. Lee. "Zero-voltage and zero-current-switching full
bridge PWM converter for high-power applications." Power Electronics, IEEE Transactions
on 11, no. 4 (1996): 622-628.
[12] W. Chen, P. Xu, and F. C. Lee. "The optimization of asymmetric half bridge converter." In
Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual
IEEE, vol. 2, 2001, pp. 703-707.
[13] Y. Liu. "High efficiency optimization of LLC resonant converter for wide load range." M.S.
thesis, Virginia Polytechnic Institute and State University, 2007.
[14] B. Yang, F. C. Lee, A. J. Zhang, and G. Huang. "LLC resonant converter for front end
DC/DC conversion." In Applied Power Electronics Conference and Exposition, 2002. APEC
2002. Seventeenth Annual IEEE, vol. 2, 2002, pp. 1108-1112.
[15] B. Lu, W. Liu, Y. Liang, F. C. Lee, and J. D. Van Wyk. "Optimal design methodology for
LLC resonant converter." In Applied Power Electronics Conference and Exposition, 2006.
APEC'06. Twenty-First Annual IEEE, 2006, pp. 6.
[16] D. Huang, S. Ji and F. C. Lee, "LLC Resonant Converter With Matrix Transformer," in IEEE
Transactions on Power Electronics, vol. 29, no. 8, Aug. 2014, pp. 4339-4347.
[18] C. Fei, F. C. Lee and Q. Li, "High-efficiency high-power-density LLC converter with an
integrated planar matrix transformer for high-output current applications," IEEE Trans. on
Industrial Electronics, vol. 64, no. 11, Nov. 2017, pp. 9072-9082.
[19] D. Reusch and F. C Lee, “High frequency bus converter with low loss integrated matrix
transformer,” in Proc. IEEE APEC 2012, pp. 1392–1397.
[20] Y. -C. Liu, K. -D Chen, C. Chen, Y. -L. Syu, G. -W. Lin, K. A. Kim and H. -J. Chiu,
"Quarter-turn transformer design and optimization for high power density 1-MHz LLC
resonant converter," IEEE Trans. on Industrial Electronics, vol. 67, no. 2, Feb. 2020, pp.
1580-1591.
89
[21] Y. -C. Liu, C. Chen, K. -D. Chen, Y. -L. Syu, D. -J. Lu, K. A. Kim and H. -J. Chiu, "Design
and implementation of a planar transformer with fractional turns for high power density LLC
resonant converters," IEEE Trans. on Power Electronics, vol. 36, no. 5, 2021, pp. 5191-503.
[22] X. Wu and H. Shi, "High Efficiency High Density 1 MHz 380–12 V DCX With Low FoM
Devices," in IEEE Transactions on Industrial Electronics, vol. 67, no. 2, Feb. 2020, pp. 1648-
1656.
[24] M. K. Ranjram and D. J. Perreault, "A 380-12 V, 1-kW, 1-MHz Converter Using a
Miniaturized Split-Phase, Fractional-Turn Planar Transformer," in IEEE Transactions on
Power Electronics, vol. 37, no. 2, Feb. 2022, pp. 1666-1681.
[25] M. K. Ranjram, P. Acosta and D. J. Perreault, "Design Considerations for Planar Magnetic
Terminations," 2019 20th Workshop on Control and Modeling for Power Electronics
(COMPEL), 2019, pp. 1-8.
[26] N. Dai, A. W. Lofti, C. Skutt, W. Tabisz and F. C. Lee, "A comparative study of high-
frequency, low-profile planar transformer technologies," Proceedings of 1994 IEEE Applied
Power Electronics Conference and Exposition - ASPEC'94, vol. 1, 1994, pp. 226-232.
[27] G. Skutt, F. C. Lee, R. Ridley and D. Nicol, "Leakage inductance and termination effects in
a high-power planar magnetic structure," Proceedings of 1994 IEEE Applied Power
Electronics Conference and Exposition - ASPEC'94, vol. 1, 1994, pp. 295-301.
[28] Y. Yang, D. Huang, F. C. Lee, and Q. Li, “Transformer shielding technique for common
mode noise reduction in isolated converters,” in Proc. IEEE Energy Convers. Congr. Expo.,
2013, pp. 4149–4153.
[29] Y. Yang, D. Huang, F. C. Lee, and Q. Li, “Analysis and reduction of common mode EMI
noise for resonant converters,” in Proc. IEEE Appl. Power Electron. Conf. Expo., 2014, pp.
566–571.
[30] A. Portolan and I. W. Hofsajer, "The Analysis and Design of an Inter-Winding Shielding
Structure of a High Frequency Transformer," 2007 IEEE Power Engineering Society
Conference and Exposition in Africa - PowerAfrica, 2007, pp. 1-6, doi:
10.1109/PESAFR.2007.4498122.
90
[31] C. Fei, Y. Yang, Q. Li and F. C. Lee, “Shielding technique for planar matrix transformers to
suppress common-mode EMI noise and improve efficiency”, IEEE. Trans. Ind. Elec., Vol.
65, No. 2, Feb 2018.
[32] Z. Ouyang, O. C. Thomsen and M. A. E. Andersen, "The analysis and comparison of leakage
inductance in different winding arrangements for planar transformer," 2009 International
Conference on Power Electronics and Drive Systems (PEDS), 2009, pp. 1143-1148, doi:
10.1109/PEDS.2009.5385844.
[33] A. F. Hoke and C. R. Sullivan, "An improved two-dimensional numerical modeling method
for E-core transformers," APEC. Seventeenth Annual IEEE Applied Power Electronics
Conference and Exposition (Cat. No.02CH37335), vol. 1, 2002, pp. 151-157.
[34] P. L. Dowell, “Effects of eddy current in transformer windings,” in Proc. Inst. Elec. Eng.,
vol. 113, 1966, no. 8, p. 1387.
[36] M. Mu, Q. Li, D. Gilham, F. C. Lee, and K. D. T. Ngo, “New core loss measurement method
for high frequency magnetic materials,” in Proc. Energy Convers. Congr. Expo., 2010, pp.
4384–4389.
[37] D. Hou, M. Mu, F. C. Lee and Q. Li, "New High-Frequency Core Loss Measurement Method
With Partial Cancellation Concept," in IEEE Transactions on Power Electronics, vol. 32, no.
4, April 2017, pp. 2987-2994.
[38] W. G. Hurley, T. Merkin and M. Duffy, "The Performance Factor for Magnetic Materials
Revisited: The Effect of Core Losses on the Selection of Core Size in Transformers," in
IEEE Power Electronics Magazine, vol. 5, no. 3, Sept. 2018, pp. 26-34.
[40] M. Mu and F. C. Lee, "A new core loss model for rectangular AC voltages," in Proc. 2014
IEEE Energy Conversion Congress and Exposition (ECCE), 2014, pp. 5214-5220.
91