Design Optimizations of LLC Resonant Converters

with Planar Matrix Transformers

Pranav Raj Prakash

Thesis submitted to the faculty of the


Virginia Polytechnic Institute and State University
in partial fulfillment of the requirements for the degree of

Master of Science
in
Electrical Engineering

APPROVED

Qiang Li, Chair


Dong Dong
Steve Southward

December 3, 2021
Blacksburg, Virginia

Keywords: LLC resonant converter, planar matrix transformer,


termination, shielding

© 2021, Pranav Raj Prakash


Design Optimizations of LLC Resonant Converters

with Planar Matrix Transformers

Pranav Raj Prakash

(Abstract)

LLC resonant converters have been a popular choice for DC-DC converters due to their high

efficiency, high power density, and hold-up capability in power supplies for communication

systems, datacenters, consumer electronics, and automobiles. With the rapid development of wide-

bandgap devices and novel magnetic materials, the push for higher switching frequencies to

achieve higher power densities at lower costs is gaining traction.

To demonstrate high efficiency and high power density, the Center for Power Electronics

Systems (CPES) at Virginia Tech designed an 800W, 1MHz 400V/12V LLC converter for future

datacenters, which could achieve a peak efficiency of 97.6% and a power density of 900 W/in3.

However, with the ever-increasing demand for online services, the performance of power delivery

must also be simultaneously improved to keep pace with the demand.

The focus of this thesis is improving the performance of CPES’ previous 400V/12V LLC

converter by investigating different aspects of its design and operation. Ultimately, design

guidelines are proposed, and improvements are demonstrated to effectively achieve higher

efficiency and higher power density than the previous CPES converter.

Multiple aspects of the LLC converter’s design and structure are investigated to further

improve its performance, and three main areas are the focus of this thesis. The output-side

termination design of the planar transformer is investigated and modeled, and design guidelines
for filter capacitor selection are provided for optimal efficiency. Next, the existing shielding

technique for matrix transformers, which helps reduce common-mode (CM) noise without

compromising on efficiency, is investigated for asymmetry and current-sharing issues, and

modifications have been proposed to improve its efficiency. Thirdly, the LLC converter’s

switching frequency is optimized to improve its performance over the previous CPES converter.

Finally, the hardware results with the proposed improvements are demonstrated, and the

converter’s performance is compared with the previous CPES converter as well as other recent

proposed solutions.
Design Optimizations of LLC Resonant Converters

with Planar Matrix Transformers

Pranav Raj Prakash

(General Audience Abstract)

The electricity demand by datacenters has been growing exponentially over the past few

decades, especially due to the boom of artificial intelligence in addition to other internet services.

This has resulted in a requirement to continually improve the efficiencies of the power delivery

from the grid, through the datacenter power architecture, and finally to the loads on the server

racks. The overall datacenter power architecture has been improved over time to improve the total

efficiency. However, the performance of each stage along the power architecture must be improved

to keep in pace with the energy demand.

The focus of this thesis is to improve the performance of the 400V/12V DC-DC stage for

future datacenters. Previously, the Center for Power Electronics Systems (CPES) at Virginia Tech

developed a 1MHz 800W 400V/12V LLC converter with 97.6% peak efficiency and 900W/in3

power density. However, the performance of the converter must be further improved to stay ahead

of the competition and keep in pace with the increasing energy demand.

Multiple aspects of the LLC converter’s design and structure are investigated to further

improve its performance, and three main areas are the focus of this thesis. Firstly, the high-

frequency termination design, or how different components are interconnected and arranged, is

studied, and a capacitance selection guideline is proposed to maximize the efficiency. Next, the
existing shielding technique for matrix transformers, which helps reduce common-mode (CM)

noise without compromising on efficiency, is investigated for asymmetry and current-sharing

issues, and modifications have been proposed to improve its efficiency. Thirdly, the LLC

converter’s switching frequency is optimized to improve its performance over the previous CPES

converter. Finally, the hardware results with the proposed improvements are demonstrated, and

the converter’s performance is compared with the previous CPES converter as well as other recent

proposed solutions.
Acknowledgments

I would like to express my heartfelt gratitude to my advisor, Dr. Qiang Li, for his guidance

and support through the entire duration of my master’s degree. His profound knowledge,

experience, and research attitude have been a blessing for me ever since I started my research. I

have learned so much about power electronics and research from him, and for that I am eternally

grateful.

I would also like to acknowledge my committee members, Dr. Dong Dong and Dr. Steve

Southward, for their support, comments, and suggestions. I would also like to thank all the staff at

CPES, whose help allowed me to focus solely on research without worrying about the paperwork.

It has also been an honor to work with the exceptionally talented students at CPES, whose

eagerness to share their knowledge without hesitation is something that I really appreciate and will

carry forward.

No words can accurately describe my love and gratitude toward my parents, Girija Prakash

and Om Prakash, who have been my lifeline throughout my existence, [A1] and wholeheartedly

supported me in my endeavors. I would also like to thank my friends in Blacksburg, who have

helped make this my home away from home. I will cherish every memory I have with them.

Finally, special thanks to the Power Management Consortium and High Density Integration

mini-consortia for sponsoring my research.

vi
Table of Contents

Chapter 1. Introduction ................................................................................................................. 1

1.1 Datacenter Power Architectures ........................................................................................ 1

1.2 Review of Previous CPES 400V/12V LLC Converter ..................................................... 5

1.3 Motivation and Outline for Thesis................................................................................... 11

Chapter 2. Termination Analysis of High-Frequency PCB-Winding Planar Transformers 15

2.1 Introduction ....................................................................................................................... 15

2.2 Parallel Resonance between Split Output Filter Capacitors......................................... 20

2.3 Impact of Filter Capacitance on the Transformer’s Termination Loss ....................... 26

2.4 Experimental Verification of Parallel Resonance .......................................................... 29

2.5 Conclusions ........................................................................................................................ 36

Chapter 3. Improved Symmetrical Shielding Technique for Planar Matrix Transformers . 38

3.1 Introduction ....................................................................................................................... 38

3.2 Current-Sharing Study in Matrix Transformers ........................................................... 45

3.3 Improved Current Sharing with Symmetrical Shielding .............................................. 48

3.4 Impact of Transformer Airgap on Leakage Inductance ............................................... 56

3.5 Hardware Verification of Efficiency Improvement ....................................................... 58

3.6 Conclusions ........................................................................................................................ 60

Chapter 4. Resonant Frequency Optimization of LLC Converters ........................................ 62

4.1 Introduction ....................................................................................................................... 62

4.2 Optimal Ferrite Material Selection at Different Frequencies ....................................... 64

vii
4.3 Resonant Converter Performance Evaluation ............................................................... 70

4.4 Hardware Verification of Proposed Performance Improvement ................................. 78

4.5 Conclusions ........................................................................................................................ 83

Chapter 5. Summary and Future Work..................................................................................... 84

References ..................................................................................................................................... 88

viii
List of Figures

Fig. 1.1. Internet traffic growth since 1987. ................................................................................... 1

Fig. 1.2. Energy consumption forecast for ICT. ............................................................................. 2

Fig. 1.3. Traditional 12V-bus architecture for datacenters. ............................................................ 3

Fig. 1.4. Current 48V-bus architecture for datacenters. .................................................................. 3

Fig. 1.5. 400V-bus architecture for future datacenters. .................................................................. 4

Fig. 1.6. The conventional half-bridge LLC resonant converter. ................................................... 6

Fig. 1.7. LLC converter with four-leg matrix transformer. ............................................................ 7

Fig. 1.8. Integration process for the four-leg matrix transformer with reduced flux density: (a)

original matrix transformer, (b) matrix transformer with flux cancelation, (c) before core

integration, and (d) after core integration. ...................................................................................... 8

Fig. 1.9. Four-layer PCB winding transformer stack-up: (a) cross-sectional view, and (b) top view.

......................................................................................................................................................... 9

Fig. 1.10. PCB winding arrangement for matrix transformer: (a) Layer 1: Secondary, (b) Layer 2:

Primary, (c) Layer 3: Primary, and (d) Layer 4: Secondary. .......................................................... 9

Fig. 1.11. Hardware prototype of the proposed LLC converter.................................................... 10

Fig. 1.12. Measured efficiency curve for previous CPES LLC converter. ................................... 11

Fig. 2.1. Winding arrangement with good interleaving but high termination loss: (a) top view, (b)

cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and

(e) magnetic field intensity plot. ................................................................................................... 16

Fig. 2.2. Winding arrangement with worse interleaving but low termination loss: (a) top view, (b)

cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and

(e) magnetic field intensity plot. ................................................................................................... 17

ix
Fig. 2.3. Modified schematic of center-tapped rectifier with split output filter capacitors: (a)

common output filter capacitors, and (b) split output filter capacitors. ........................................ 18

Fig. 2.4. Secondary-side termination in the previous CPES 400V/12V LLC converter: (a) top layer,

(b) bottom layer, and (c) 3D view of component and via layout in one elemental transformer. .. 19

Fig. 2.5. (a) Parasitic loop connecting 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡, and (b) equivalent schematic with parasitic

loop inductance 𝐿𝑠. ....................................................................................................................... 21

Fig. 2.6. (a) Secondary-side termination schematic with parallel ringing loop, and (b) equivalent

impedance model. ......................................................................................................................... 22

Fig. 2.7. Magnitude, real and imaginary parts of Z against frequency. ........................................ 24

Fig. 2.8. Modified equivalent circuit model including capacitor ESR. ........................................ 26

Fig. 2.9. Impact of capacitor ESR on equivalent termination resistance. ..................................... 27

Fig. 2.10. 𝑅𝑒 vs. frequency for different capacitors. .................................................................... 28

Fig. 2.11. Schematic of one elemental transformer with CT rectifiers and loop parasitics. ......... 30

Fig. 2.12. Equivalent circuit model of transformer reflected to primary side. ............................. 30

Fig. 2.13. Magnetizing inductance measurement: (a) open-circuit secondary, (b) equivalent circuit

model, and (c) impedance and resistance measurement results. ................................................... 31

Fig. 2.14. Leakage inductance measurement: (a) short-circuit secondary, (b) equivalent circuit

model, and (c) impedance and resistance measurement results. ................................................... 32

Fig. 2.15. (a) 16034E probe with device under test (DUT), and (b) capacitor parameter

measurement. ................................................................................................................................ 33

Fig. 2.16. Simulated AC 𝐿𝑠 and 𝑅𝑠 as a function of frequency. .................................................. 34

Fig. 2.17. Measured and modeled equivalent transformer resistance versus frequency. .............. 35

x
Fig. 3.1. (a) Schematic of LLC converter with switching nodes, and (b) CM noise sources and

coupling paths. .............................................................................................................................. 38

Fig. 3.2. (a) LLC converter schematic, and (b) six-layer PCB stack-up....................................... 40

Fig. 3.3. Equipotential shield windings: (a) shield and secondary windings, and (b) potential

mapping across the windings. ....................................................................................................... 40

Fig. 3.4. Modified shielding technique with shielding as part of the primary. ............................. 42

Fig. 3.5. PCB winding arrangement for proposed shielding: (a) transformer schematic with

proposed shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4: primary, and (e)

Layer 5: shielding. ........................................................................................................................ 43

Fig. 3.6. Hardware prototype of 400V/12V LLC with proposed shielding. ................................. 44

Fig. 3.7. Hardware testing results of 400V/12V LLC with proposed shielding: (a) CM noise

comparison, and (b) converter efficiency comparison. ................................................................. 44

Fig. 3.8. Waveforms of interest on the secondary side during one-half of a cycle of operation. . 46

Fig. 3.9. 𝑉𝐷𝑆 waveforms of SRs during the turn-off instant: (a) first half-cycle, (b) second half-

cycle, and (c) SR positions on the transformer. ............................................................................ 47

Fig. 3.10. Conducting layer proximities with the original shielding technique: (a) first half-cycle,

and (b) second half-cycle. ............................................................................................................. 48

Fig. 3.11. 3D FEA simulated leakage inductances of secondary windings with original shielding.

....................................................................................................................................................... 49

Fig. 3.12. Conducting layer proximities with the modified shielding technique: (a) first half-cycle,

and (b) second half-cycle. ............................................................................................................. 50

Fig. 3.13. 3D FEA simulated leakage inductances of secondary windings with modified shielding.

....................................................................................................................................................... 50

xi
Fig. 3.14. PCB winding arrangement for improved shielding: (a) transformer schematic with

improved shielding, (b) Layer 2: shielding, (d) Layer 4: primary, and (e) Layer 5: shielding. .... 51

Fig. 3.15. 3D FEA simulated current density comparison between original and improved shield:

(a) Layer 2 shield in original shielding, (b) Layer 5 shield in original shielding, (c) Layer 2 shield

in improved shielding, and (d) Layer 5 shield in improved shielding. ......................................... 52

Fig. 3.16. Current directions in the paralleled shield windings in the improved shielding: (a)

Layer 2 shield, and (b) Layer 5 shield. ......................................................................................... 52

Fig. 3.17. Electric field distribution within the layers of a PCB transformer with CT rectifiers.. 53

Fig. 3.18. Interwound parallel shield layers to homogenize the electric field around them: (a) cross-

section view, and (b) current flow in 3D view.............................................................................. 54

Fig. 3.19. Current density in the paralleled shield windings with interleaved shielding: (a)

Layer 2 shield, and (b) Layer 5 shield. 55

Fig. 3.20. PCB winding arrangement for improved and interleaved shielding: (a) transformer

schematic with improved shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4:

primary, and (e) Layer 5: shielding............................................................................................... 55

Fig. 3.21. Asymmetrical leakage inductance and current sharing with airgap on one end of

transformer: (a) leakage inductance path for secondary, and (b) 𝑉𝐷𝑆 of SRs during turn-off. ... 57

Fig. 3.22. Symmetrical fringing flux and current sharing with airgap in the middle of transformer:

(a) fringing flux with airgap in the middle, and (b) 𝑉𝐷𝑆 of SRs during turn-off. ........................ 57

Fig. 3.23. Efficiency reduction when moving the airgap to the middle........................................ 58

Fig. 3.24. Efficiency improvement with improved shielding. ...................................................... 59

Fig. 3.25. CM Noise measurement spectra. .................................................................................. 60

xii
Fig. 4.1. Converter losses that increase with switching frequency: (a) device switching loss, (b)

device conduction loss, and (c) transformer winding loss. ........................................................... 63

Fig. 4.2. Transformer core loss decreases with switching frequency. .......................................... 63

Fig. 4.3. Loss breakdown of 400V/12V LLC converter at 1 MHz. .............................................. 64

Fig. 4.4. Flowchart showing switching-frequency optimization process. .................................... 64

Fig. 4.5. Performance factors of ferrite materials at 𝑃𝑣 = 0.5𝑊/𝑐𝑚3. ....................................... 69

Fig. 4.6. Performance factor comparison at different core loss densities: (a) 𝑃𝑣 = 0.3𝑊𝑐𝑚3, and b

𝑃𝑣 = 0.7𝑊/𝑐𝑚3. ......................................................................................................................... 70

Fig. 4.7. Copper thickness optimization at different frequencies. ................................................ 72

Fig. 4.8. Matrix transformer dimensions. ..................................................................................... 73

Fig. 4.9. Transformer loss optimization. ....................................................................................... 73

Fig. 4.10. Minimum transformer loss vs. transformer footprint. .................................................. 74

Fig. 4.11. Different converter losses as a function of resonant frequency. ................................... 76

Fig. 4.12. Magnetic flux density in the transformer: (a) top view, and (b) cross-sectional view. 76

Fig. 4.13. Full-load efficiency versus power density at different frequencies. ............................. 77

Fig. 4.14. Hardware prototype of proposed converter. ................................................................. 78

Fig. 4.15. 400V/12V LLC converter operating waveforms: (a) light load (10%, 100 W), and (b)

full load (100%, 1 kW). ................................................................................................................ 80

Fig. 4.16. Thermal performance of LLC converter. ..................................................................... 81

Fig. 4.17. 400V/12V LLC converter efficiency. ........................................................................... 82

Fig. 4.18. Comparison of the converter loss breakdown at full load. ........................................... 82

Fig. 5.1. Converter efficiency comparison with other works. ...................................................... 87

xiii
List of Tables

Table 1.1. iNEMI specifications for the DC/DC converter. ........................................................... 5

Table 1.2. Specifications of the proposed LLC converter. ........................................................... 10

Table 1.3. Performance summary of other recent 400V/12V unregulated DC-DC converters. ... 12

Table 2.1. Summary of selected capacitors. ................................................................................. 34

Table 4.1. Steinmetz coefficients for 3F3 from datasheet. ........................................................... 66

Table 4.2. Steinmetz coefficients for ML-91s from datasheet...................................................... 66

Table 4.3. Mn-Zn ferrite materials selected for core loss testing. ................................................ 67

Table 4.4. Summary of materials with highest performance factors. ........................................... 69

Table 4.5. Optimal transformer dimensions. ................................................................................ 75

Table 4.6. Specifications of the proposed LLC converter. ........................................................... 79

Table 5.1. Updated performance summary of recent 400V/12V unregulated DC-DC converters.

....................................................................................................................................................... 86

xiv
Chapter 1. Introduction

1.1 Datacenter Power Architectures

Since the turn of the century, the internet has become an integral part of almost everyone’s life,

with it being used for increasingly widespread tasks, ranging from launching space shuttles to

purchasing groceries. Moreover, with the advent of artificial intelligence, the internet traffic to and

from datacenters has exploded exponentially [1], as Fig. 1.1 shows.

Fig. 1.1. Internet traffic growth since 1987.

Internet traffic increased 30,000 times from 1987 to 1997, further increasing by over a

thousand times in the next 10 years. In the past decade, with the advent of data-hungry artificial

intelligence in addition to other online services like banking, e-commerce, social media, and cloud

storage, internet traffic has boomed to a mammoth 1.1 ZB.

This trend is expected to continue into the future, as forecasts suggest that the total electricity

demand of information and communication technology (ICT) will accelerate in the 2020s to up to

1
20% of the total electricity demand, and that datacenters will take up almost around 40% of that,

as shown in Fig. 1.2.

Fig. 1.2. Energy consumption forecast for ICT.

Because of the increased energy demand by datacenters, big tech companies such as Google,

Amazon, Facebook, and Microsoft are building massive datacenter farms called hyperscale

datacenters to serve small- and medium-sized enterprises, which can consume up to 200 MW per

datacenter. The estimated annual spending on datacenter systems worldwide is almost $200

billion, out of which around 40% is estimated to be spent on the power and cooling infrastructure.

Given the rising demand for online services, efficiency gains at every stage are essential to

maintaining a sustainable level of global energy consumption, particularly for countries seeking to

reduce their carbon footprint.

2
Fig. 1.3. Traditional 12V-bus architecture for datacenters.

The datacenter power architecture is one significant area where efficiency could be improved.

Fig. 1.3 shows the conventional 12V bus architecture for datacenters, with the approximate

efficiencies of each stage. The 60Hz transformer is followed by the AC/DC and the DC/AC stages

necessary to connect the uninterruptible power supply (UPS). This is followed by the power

distribution unit (PDU), which includes another 60Hz transformer, as well as switches and relays

to distribute the AC voltage to different server cabinets. Within each server cabinet, there are

power supply units (PSUs) consisting of the AC/DC and isolated DC/DC stages, which are front-

end converters, finally followed by the voltage regulators (VRs) that supply various loads. Adding

up the efficiencies of these numerous stages results in a net efficiency of only 73% [3][4].

Fig. 1.4. Current 48V-bus architecture for datacenters.

Due to the low bus voltage and multiple conversion stages in the traditional 12V-bus

architecture, Google came up with an improved architecture with a higher bus voltage of 48V

3
[5][6]. The PDU now has only switches and relays to distribute the power to different cabinets,

and hence has higher efficiency. Moreover, the UPS is now moved to the 48V DC bus inside the

server racks, thereby eliminating the AC/DC and DC/AC stages required to connect the UPS to

the AC side, and hence reducing the number of power-conversion stages. This fact, coupled with

the higher bus voltage having lower i2R losses, results in a much higher net efficiency of 80%, 7%

higher than the traditional 12V bus architectures; this is approximately equal to the energy

produced by 33 nuclear power plants every month [7].

[A2]

Fig. 1.5. 400V-bus architecture for future datacenters.

Recently, the 400V DC bus architecture has gained traction due to its much lower i2R losses,

and subsequently lower cost due to fewer transmission cables as compared to the 48V bus

architecture [8][9]. This results in a higher overall power architecture efficiency of 83%, 10%

higher than the traditional 12V architecture; this amount is approximately equal to the energy

produced by 47 nuclear power plants every month. This architecture requires a DC/DC converter

that can directly step-down the 400V bus voltage to 12V to supply the VRs. Industry standards for

this on-board converter were proposed by the International Electronics Manufacturing Initiative

(iNEMI) [10], as summarized in Table 1.1.

4
Table 1.1. iNEMI specifications for the DC/DC converter.

ITEM Minimum Nominal Maximum


Input Voltage 360Vdc 380Vdc 400Vdc
Efficiency 92%@10% Load 96%@Full Load 97%@50% Load
Output Voltage 11.60Vdc 12.00Vdc 12.60Vdc
Output Current 0A 62.5A
Packaging DOSA Quarter Brick Form Factor

1.2 Review of Previous CPES 400V/12V LLC Converter

The iNEMI specifications for the DC-DC converter require a high voltage step-down ratio, high

output-current capability, high efficiency, and high power density, which is challenging. Hard-

switching pulse-width modulation (PWM) converters cannot achieve the required efficiency and

power density due to their high switching losses at higher frequencies. Among soft-switching

PWM converters, different candidates, such as asymmetrical half-bridge converters and phase-

shifting full-bridge PWM converters, have been implemented as DC/DC converters [11][12].

However, they must sacrifice their normal operation efficiency to accommodate the large input

voltage range for hold-up requirements in such applications.

Resonant converters are great choices for DC/DC converters due to their ability to achieve soft-

switching over the entire load range and the lower turn-off losses incurred for their primary devices

(as compared to their hard-switching counterparts), resulting in high efficiencies and high power

densities. Among them, LLC converters have been demonstrated to be promising candidates for

DC/DC converters, due to their ability to achieve high gains for hold-up, while maintaining high

5
efficiencies during normal operations, while also reducing the electromagnetic interference due to

their soft-switching capability [13][14][15].

Fig. 1.6. The conventional half-bridge LLC resonant converter.

However, for a high output current of 67A (12V, 800W), the transformer’s secondary winding

loss and the secondary-rectifier (SR) conduction loss are too high to achieve the required

efficiencies. Hence, multiple SRs and secondary windings must be effectively paralleled to reduce

the conduction losses, as shown in Fig. 1.6. However, at the locations denoted by the red dots in

Fig. 1.6, the termination loss is too high when connecting multiple SRs to the secondary windings.

To address these issues, CPES proposed a novel structure, termed a matrix transformer,

wherein the transformer is broken down into multiple smaller transformers that are then connected

such that the primary windings are in series and the secondary windings are in parallel [16][17].

Most recently, [18] proposed a matrix transformer consisting of four smaller transformers, each

with a 4:1 turns ratio, as shown in Fig. 1.7. This way, as the secondary current is distributed equally

among the paralleled secondary windings, it correspondingly reduces the net secondary winding

loss. In addition, the SR termination loss can be minimized as the SRs don’t have to be paralleled

6
on a single secondary winding, but instead can be placed individually on the paralleled secondary

windings, thereby also mitigating the secondary winding leakage inductances.

Fig. 1.7. LLC converter with four-leg matrix transformer.

[A3]

(a) (b)

(c) (d)

Fig. 1.8. Integration process for the four-leg matrix transformer with reduced flux density: (a)
original matrix transformer, (b) matrix transformer with flux cancelation, (c) before core
integration, and (d) after core integration.

7
The process of integrating the four elementary transformers into one matrix transformer is

shown in Fig. 1.8. The original matrix transformer with four sets of UI[A4] cores has excessive core

loss due to the redundant core legs, as shown in Fig. 1.8 (a). However, two UI cores can be

combined if the primary turns are wound in opposite directions, and hence the vacant legs can be

removed since they have equal and opposite magnetic fluxes; this results in two sets of UI cores,

as shown in Fig. 1.8 (b). Furthermore, core 2 can be rotated by 1800, as shown in Fig. 1.8 (c), such

that upon integration of all four elemental transformers under one core, the magnetic flux in the

plate is evenly distributed. This way, only half the flux from each leg flows to the two adjacent

legs, resulting in low core loss in the plates.

Using traditional litz-wires for the transformer windings is difficult for manufacturing and

mass production, and hence printed circuit board (PCB) -based windings have been used in recent

works, due to the ease with which they can be designed and manufactured [16][17][19]. Fig. 1.9

(a) shows the four-layer PCB layer stack for the matrix transformer in [18]. The two primary layers

are sandwiched in between the two secondary layers on the top and bottom layers. This way, the

SRs and output filter capacitors can be placed directly on the secondary windings to minimize the

termination losses and secondary winding leakage inductance, as shown in Fig. 1.9 (b).

(a) (b)

Fig. 1.9. Four-layer PCB winding transformer stack-up: (a) cross-sectional view, and (b) top
view.

8
[A5]

(a) (b)

(c) (d)

Fig. 1.10. PCB winding arrangement for matrix transformer: (a) Layer 1: Secondary, (b) Layer 2:
Primary, (c) Layer 3: Primary, and (d) Layer 4: Secondary.

Fig. 1.10 shows the PCB winding arrangement for the matrix transformer; the yellow arrows

show the current direction in the windings. The 16 primary turns are wound among the four

elemental transformers between the two primary layers. Each elemental transformer has two

primary turns per layer, with vias being employed to connect the two layers between each

elemental transformer. The primary terminals are right next to each other to minimize the leakage

9
inductance and termination loss. The secondary side employs center-tapped rectification, and

hence only one set of SRs are active in each half-cycle of operation. The SRs and output filter

capacitors are placed directly on the winding, which allows the secondary current to perfectly

interleave with the primary, resulting in minimum leakage inductance and AC termination loss.

Moreover, the SRs conducting in one half-cycle are alternatively placed on the two secondary

layers to have symmetrical interleaving between the primary and secondary currents.

A hardware prototype for the 800W 380V/12V LLC DC-DC converter running at a fixed

frequency of 1 MHz was developed as shown in Fig. 1.11, and the specifications for the proposed

converter are shown in Table 1.2.

Fig. 1.11. Hardware prototype of the proposed LLC converter.

Table 1.2. Specifications of the proposed LLC converter.

Component Parameters
Resonant Frequency 1MHz
Dead Time 90ns
Transformer Turns Ratio 16:1
Primary Devices PGA26E08
Secondary Devices BSC0500NSI
Primary Driver Si8273
Secondary Drivers FAN3122
Resonant Capacitor 71nF
Resonant Inductance 312nH
Magnetizing Inductance 25uH

10
Fig. 1.12. Measured efficiency curve for previous CPES LLC converter.

The power density of the 800W converter is 930 W/in3, and the measured efficiency curve is

shown in Fig. 1.12. It can achieve 92.5% at light load (10% load), 97.6% peak, and 97.2% at full

load, all of which satisfies the iNEMI requirements, as shown by the pink curve in Fig. 1.12.

1.3 Motivation and Outline for Thesis

As discussed in Section 1.1, the energy demand of datacenters is increasing exponentially,

which has resulted in significant interest to realize the 400V-bus architecture for datacenters.

Hence, the 400V/12V DC-DC converter has been the recent research focus of many groups

[20][21][22][23][24]; a summary comparison of performance levels including the previous CPES

converter [18] are listed in Table 1.3. Some research [20],[21] and [24] has demonstrated different

ways the partial-turn transformer concept can be implemented effectively for the 380V/12V LLC

converter, resulting in high power densities and efficiencies. One research work [22] uses series-

connected low-voltage primary Si MOSFETs to reduce the device losses. Another example [23]

is ViCOR’s 800W bus converter module that offers high power density.

11
Table 1.3. Performance summary of other recent 400V/12V unregulated DC-DC converters.

ITEM [18] [20] [21] [22] [23] [24]


Rated Power 800W 1kW 800W 1.8KW 800W 1kW
Operating
1MHz 1MHz 1MHz 1MHz 1MHz 1MHz
Frequency
Peak Efficiency 97.6% 97% * 96.5% * 98.3% * 97.4% 97.3%
Power Density 900W/in3 640W/in3** 900W/in3** 810W/in3 1177W/in3 -
* Without Driving Loss ** Without Controller

The efficiency values with a * denote that they do not include the device’s driving losses. For

example, [22] reports 98.3% peak efficiency, which is higher than that of the previous CPES work

due to lower device losses. However, it has significantly higher device driving losses (~9W) from

switching 16 Si MOSFETs, and this results in an estimated 97% peak efficiency. The power

density values with a ** denote that they do not include the controller circuit as part of the power

density.

To summarize, new developments in magnetic and converter designs are pushing the

efficiencies and power densities higher, which leads to the motivation to attempt to further improve

the performance of the CPES 400V/12V LLC converter such that it can compete with state-of-the-

art performance levels. This is the primary objective of this thesis. Three major areas of potential

performance improvement have been identified – matrix transformer termination design analysis,

the shielding technique used to suppress common-mode (CM) noise in matrix transformers and

optimizing the switching frequency of the LLC converter to improve efficiency and power density.

In Chapter 1, the current trends in datacenter energy requirements are discussed, and how

improvements in datacenter power architecture, achieved by pushing the bus voltage from the

traditional 12V up to 400V, can help improve the overall power architecture efficiency. The 400V

12
bus requires a 400V/12V DC-DC converter with high efficiency and high power density. CPES

has developed a 400V/12V LLC converter rated at 800W, which is briefly reviewed. Moreover,

the current technology landscape of the 400V/12V DC-DC converters for future datacenters is

surveyed, leading to the motivation to further improve the performance of the CPES 400V/12V

LLC converter to (a) keep the performance improvement at pace with ever-increasing energy

demands, and (b) outperform other recent works.

In Chapter 2, different termination techniques for the high-frequency matrix transformers with

center-tapped rectifiers are discussed. The termination design must be carefully considered,

especially at high-frequency operations, where the transformer leakage inductances can result in

high AC termination losses. In this chapter, the termination design in the previous CPES

400V/12V LLC converter is analyzed. Due to the presence of output filter capacitors on both

secondary layers (top and bottom layers), there is a parasitic path between the two filter capacitor

sets that has some parasitic loop inductance, which resonates with the capacitors to result in parallel

LC resonance peaks. This behavior is analyzed, and design guidelines are provided to move the

parallel LC resonant frequency away from the converter resonant frequency in order to minimize

this impact, and hence lessen transformer impedance, at the resonant frequency. The complete

transformer including the termination is modeled and verified with hardware measurements.

In Chapter 3, the shielding technique in matrix transformers is studied. Due to the large

overlapping surface area between the primary and secondary windings in planar transformers, the

inter-winding capacitance is high. The high dV/dt in the primary side causes CM noise to flow

through the inter-winding capacitance then into the secondary side, resulting in high CM noise at

the load. To attenuate this, shield layers are placed between the primary and secondary layers and

are connected back to the primary ground, such that the induced CM noise flows back into the

13
primary side. CPES previously designed a shielding technique with conducting shield layers,

which, in addition to suppressing the CM noise, also increases the effective turns number of the

transformer, thereby reducing the primary-side loss, and improving efficiency. However, there are

inherent current-sharing issues in the converter due to asymmetrical leakage inductances in the

two half-cycles of operation, resulting in a reduction in efficiency. This phenomenon is studied in

detail, and solutions are proposed; these are verified with hardware testing. In addition, the impact

the position of the transformer airgap relative to the PCB windings has on its leakage inductance

is also briefly discussed.

In Chapter 4, the switching frequency of the LLC converter is optimized. The LLC converter

operates at a fixed switching frequency, which equals the resonant frequency, when it operates as

a DC-DC transformer. Most of the losses in the converter are dependent on the switching frequency,

and hence its optimization is vital for achieving the greatest performance from the converter. To

optimize the switching frequency, the best ferrite material for the transformer core must be selected

for each switching frequency. To make this selection, the core loss densities of various materials

are measured, and their performance factors are compared to determine the best materials at

different frequency ranges. Next, the converter efficiencies and power densities are compared at

different switching frequencies, and the optimal switching frequency is selected. Finally, the

performance improvement is verified with hardware experiments carried out on the converter

operating at the optimal switching frequency.

Chapter 5 presents a summary of the work done in this thesis and explores options for future

work.

14
Chapter 2. Termination Analysis of High-Frequency

PCB-Winding Planar Transformers

2.1 Introduction

The benefits of switching to PCB winding-based transformers from the traditional litz wire-

based transformers are multifold, and include easier manufacturability, strong repeatability, and a

larger surface area resulting in low-profile cores and better thermal capabilities. Moreover, the

planar magnetic windings can be pushed to higher frequencies, as compared to the traditional litz-

wire windings, hence reducing the magnetic core size [25]. However, in high-current applications,

multiple PCB layers must be paralleled in order to achieve low DC resistance. This results in an

increase in the number of termination connections to be made.

In high-frequency, high-current planar transformers, in addition to the core loss and winding

loss, the total transformer loss also includes termination loss. The termination loss has two main

components – (a) loss from the vias, which interconnect the multiple parallel layers, and (b) loss

from the winding segments that extend outside the core for termination in the external circuitry,

which includes the SRs and the output filter capacitors.

Significant work has been done to study the termination in planar transformers; multiple

aspects, such as the optimal number of PCB layers, interleaving and relative positioning of the

primary and secondary layers, and optimally connecting the secondary winding terminals to the

SRs and output filter capacitors have been studied [25][26][27]. For the four-layer planar

transformer employed for 400V/12V LLC converters, the termination for the center-tapped

15
rectifiers has been studied and optimized in the previous converters developed by CPES, as

summarized in Fig. 2.1 and Fig. 2.2 [16][17][18].

(a) (b) (c)

(d) (e)

Fig. 2.1. Winding arrangement with good interleaving but high termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
(e) magnetic field intensity plot.

Fig 2.1 shows a winding arrangement in which the top and bottom layers contain the primary

windings and the middle layers are for the secondary windings. This arrangement has very good

interleaving due to the low peak magneto-motive force (MMF) in the transformer, as shown in Fig.

2.1 (c). However, the termination design becomes challenging in this arrangement, as the

secondary winding terminals in the middle layers must be connected to the SRs and output filter

capacitors on the top and bottom layers using vias, resulting in high via loss. Moreover, the SRs

and filter capacitors must be placed outside the transformer area, resulting in poor interleaving in

16
the non-overlapping area outside the transformer, as seen by the high magnetic field intensity in

Fig. 2.1 (d). The 3D finite element analysis (FEA) simulation of the secondary windings with this

termination at 1 MHz results in AC resistance R sec = 6.81 𝑚Ω and leakage inductance 𝐿𝑘 =

176.4𝑛𝐻.

(a) (b) (c)

(d) (e)

Fig. 2.2. Winding arrangement with worse interleaving but low termination loss: (a) top view, (b)
cross-section view, (c) MMF distribution, (d) FEA simulation of current density distribution, and
(e) magnetic field intensity plot.

Fig 2.2 shows a winding arrangement in which the top and bottom layers contain the

secondary windings and the middle layers are for the primary windings. This arrangement allows

the SRs and output filter capacitors to be on the same layers as the secondary windings, which

eliminates the requirement of vias for connection. Moreover, the SRs and output capacitors can

now be placed directly on the windings themselves, as shown in Fig. 2.2 (a), resulting in much

17
better overlapping between the primary and secondary current, and hence improving both

components of the termination design. The 3D FEA simulation for the secondary windings of this

improved termination at 1 MHz results in AC resistance R sec = 1.37 𝑚Ω and leakage inductance

𝐿𝑘 = 36.6𝑛𝐻. These values are almost one-third the values obtained from the previous termination,

highlighting the fact that even with worse inherent interleaving, drastic improvements in

termination lead to much lower AC resistances and leakage inductances of the transformer.

As evident from the previous designs, the center-tapped rectifier circuit is split between the

top and bottom secondary layers, such that only one layer is required to conduct in each half-cycle.

However, this also means that the output filter capacitors must be split into two and placed on each

secondary layer to achieve an optimal termination loop. Hence, the center-tapped rectification

schematic can be redrawn with split output filter capacitors, as shown in Fig. 2.3, for one elemental

transformer, with the two sets of split output filter capacitors being named 𝐶𝑡𝑜𝑝 and 𝐶𝑏𝑜𝑡 . The red

loop shows the termination loop in one half-cycle.

(a) (b)

Fig. 2.3. Modified schematic of center-tapped rectifier with split output filter capacitors: (a)
common output filter capacitors, and (b) split output filter capacitors.

18
Based on this, the secondary-side termination for the four-leg matrix transformer in the

previous CPES 400V/12V LLC converter with center-tapped rectifiers was designed as shown in

Fig. 2.4 [17].

(a) (b)

(c)

Fig. 2.4. Secondary-side termination in the previous CPES 400V/12V LLC converter: (a) top
layer, (b) bottom layer, and (c) 3D view of component and via layout in one elemental
transformer.

19
The four elemental transformers are separately connected to the load, as shown by the red and

black arrows pointing outward from the transformer terminals. The output filter capacitors on the

top secondary layer are labeled 𝐶𝑡𝑜𝑝 and those on the bottom secondary layer are labeled 𝐶𝑏𝑜𝑡 .

SR1, SR3, SR5, and SR7 conduct in the first half-cycle, and, along with their corresponding filter

capacitors, are colored in. SR2, SR4, SR6, and SR8 conduct in the second half-cycle, and, along

with their corresponding filter capacitors, are greyed out. Since the output currents from both half-

cycles must be merged to be sent to the load, vias are needed outside the transformer to combine

the output currents using the middle layers. The current flow arrows and the termination vias used

by the secondary current in the first half-cycle are shown in yellow, and those used in the second

half-cycle are purple.

Ideally, all AC components of the output current will be filtered out by the output capacitors,

resulting in only the DC current merging through the vias and going to the load. However, as will

be studied in this chapter, there is an alternative path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 that results in circulating

current, which has its own parasitic loop inductance and resistance. This inductance is shown to

resonate with the capacitors, resulting in parallel resonance at a certain frequency, which if within

the vicinity of the switching frequency, can result in increased transformer termination losses, and

hence, lower efficiencies. This phenomenon is investigated, and capacitor selection guidelines are

proposed for optimal design.

2.2 Parallel Resonance between Split Output Filter Capacitors

The split output capacitors, which are on the top and bottom layers, must be paralleled and

connected to the load. However, since the secondary current flows in opposite directions in the

two half-cycles, the positions of the SR and the filter capacitors are interchanged on the two

20
secondary layers. This results in a long path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 , as shown in Fig. 2.5 (a), which

shows the transformer layers of elemental transformer #4. The red loop indicates the secondary

current termination loop, and the yellow loop shows the path from 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 through the middle

layers. A simplified equivalent schematic can then be drawn as shown in Fig. 2.5 (b), in which the

parasitic loop connects 𝐶𝑡𝑜𝑝 and 𝐶𝑏𝑜𝑡 through 𝐿𝑠 .

[A6]

(a) (b)

Fig. 2.5. (a) Parasitic loop connecting 𝐶𝑡𝑜𝑝 to 𝐶𝑏𝑜𝑡 , and (b) equivalent schematic with parasitic

loop inductance 𝐿𝑠 .

The equivalent impedance model of the termination circuit must be studied to understand the

behavior of the parasitic loop. Fig. 2.6 (a) shows the modified schematic of the termination

including termination resistance 𝑅𝑡𝑒𝑟𝑚 and parasitic loop resistance 𝑅𝑠 . Fig 2.6 (b) shows the

equivalent impedance network of the secondary-side termination during the first half-cycle across

the two red dots in Fig. 2.6 (a) and includes the capacitor ringing loop.

21
It can be observed that there is a parallel resonant loop in the circuit, represented by the yellow

loop, which can result in high impedance if the loop’s resonant frequency is around the converter’s

switching frequency. This loop needs to be carefully analyzed and optimized.

(a) (b)

Fig. 2.6. (a) Secondary-side termination schematic with parallel ringing loop, and (b) equivalent
impedance model.

It can be realistically and reasonably assumed that 𝐶𝑡𝑜𝑝 = 𝐶𝑏𝑜𝑡 . Therefore, the net impedance

𝑍 of the termination network can be expressed as:

1
𝑍 = 𝑅𝑡𝑒𝑟𝑚 + ,
1 1 (2.1)
𝑍1 + 𝑍2

where 𝑍1 and 𝑍2 are the impedances of the two parallel branches, given by:

1 1
𝑍1 = 𝑎𝑛𝑑 𝑍2 = 𝑠𝐿𝑠 + + 𝑅𝑠 . (2.2)
𝑠𝐶𝑡𝑜𝑝 𝑠𝐶𝑡𝑜𝑝

22
where 𝑠 = 𝑗𝜔 , and 𝜔 is the angular frequency, given by 𝜔 = 2𝜋𝑓 . Therefore, (2.2) can be

substituted into (2.1) to result in:

1
𝑍 = 𝑅𝑡𝑒𝑟𝑚 + ,
𝑠𝐶𝑡𝑜𝑝 (2.3)
𝑠𝐶𝑡𝑜𝑝 + 2
1 + 𝑠 𝐿𝑠 𝐶𝑡𝑜𝑝 + 𝑠𝑅𝑠 𝐶𝑡𝑜𝑝

which can be further expanded to get:

1 + 𝑠 2 𝐿𝑠 𝐶𝑡𝑜𝑝 + 𝑠𝑅𝑠 𝐶𝑡𝑜𝑝


𝑍 = 𝑅𝑡𝑒𝑟𝑚 + 3 2 2 . (2.4)
𝑠 𝐿𝑠 𝐶𝑡𝑜𝑝 + +𝑠 2 𝑅𝑠 𝐶𝑡𝑜𝑝 + 2𝑠𝐶𝑡𝑜𝑝

This results in a third-order transfer function due to the presence of the three energy-storage

elements 𝐶𝑡𝑜𝑝 , 𝐶𝑏𝑜𝑡 and 𝐿𝑠 .

To study the impact of this termination impedance on the transformer loss, the equivalent

resistance, or the real part, of the impedance network must be evaluated. To achieve this, 𝑠 = 𝑗𝜔

is substituted into (2.4), and the complex conjugate of the denominator is multiplied and divided

to result in:

(1 − 𝜔2 𝐿𝑠 𝐶𝑡𝑜𝑝 + 𝑗𝜔𝑅𝑠 𝐶𝑡𝑜𝑝 )[−𝜔2 𝑅𝑠 𝐶𝑡𝑜𝑝


2
− 𝑗(2𝜔𝐶𝑡𝑜𝑝 − 𝜔3 𝐿𝑠 𝐶𝑡𝑜𝑝
2
)]
𝑍 = 𝑅𝑡𝑒𝑟𝑚 + 2 2 . (2.5)
2 2
(𝜔 2 𝑅𝑠 𝐶𝑡𝑜𝑝 ) + (2𝜔𝐶𝑡𝑜𝑝 − 𝜔 3 𝐿𝑠 𝐶𝑡𝑜𝑝 )

The total impedance can now be separated into the real and imaginary parts as:

𝑍 = 𝑅𝑒 + 𝑗𝑋𝑒 , (2.6)

where [PPR7] 𝑅𝑒 is the equivalent resistance of the impedance network, 𝑋𝑒 is the equivalent

reactance of the impedance network. Upon further simplifying (2.5), the following expressions for

𝑅𝑒 and 𝑋𝑒 are obtained:

23
𝑅𝑠
𝑅𝑒 = 𝑅𝑡𝑒𝑟𝑚 + 2 2 , 𝑎𝑛𝑑 (2.7)
𝐶𝑡𝑜𝑝 𝐿2𝑠 𝜔 4 + 𝐶𝑡𝑜𝑝 𝑅𝑠 𝜔 2
2 − 4𝐶𝑡𝑜𝑝 𝐿𝑠 𝜔 2 + 4

𝐶𝑡𝑜𝑝 (𝐿2𝑠 𝜔4 + 𝑅𝑠2 𝜔2 )


𝐿𝑠 𝜔 − 1
𝑋𝑒 = 2 2 4 2𝜔 − , (2.8)
2
𝐶𝑡𝑜𝑝 𝐿𝑠 𝜔 + 𝐶𝑡𝑜𝑝 𝑅𝑠2 𝜔 2 − 4𝐶𝑡𝑜𝑝 𝐿𝑠 𝜔 2 + 4 2𝐶𝑡𝑜𝑝 𝜔

Clearly, |𝑍|, 𝑅𝑒 and 𝑋𝑒 are a function of the frequency and can be plotted as shown in Fig. 2.7.

Fig. 2.7. Magnitude, real and imaginary parts of Z against frequency.

The above graph was plotted with the following parameters:

𝐶𝑡𝑜𝑝 = 𝐶𝑏𝑜𝑡 = 3 × 10 𝜇𝐹, 𝐿𝑠 = 3.1 𝑛𝐻, 𝑅𝑠 = 4.4 𝑚Ω, 𝑅𝑡𝑒𝑟𝑚 = 2 𝑚Ω.

The blue, green, and red curves show |𝑍|, 𝑋𝑒 and 𝑅𝑒 respectively. It can be observed that at

low frequencies, the impedance network is predominantly capacitive, with infinitely high

reactance, and hence impedance at 𝜔 = 0. However, at a particular frequency 𝜔0 where there is

parallel resonance between 𝐶𝑡𝑜𝑝 , 𝐶𝑏𝑜𝑡 and 𝐿𝑠 , there is a large circulating energy between the

energy storage elements, resulting in high impedance in the network at the parallel resonant

24
frequency. However, the high circulating current also passes through 𝑅𝑠 , which is in series with

𝐿𝑠 . This results in an increase in the termination resistance at parallel resonant frequency too.

Hence, 𝑅𝑒 dominates the network impedance around the parallel resonant frequency, and since it

represents the real loss in the network, its analysis is essential to study the gather information about

the transformer’s termination loss.

The parallel resonant frequency can be calculated simply by setting 𝑋𝑒 = 0 for the parallel

resonant circuit, resulting in the following expression for the parallel resonant frequency, 𝜔0 :

1
𝜔0 = . (2.9)
√0.5𝐶𝑡𝑜𝑝 𝐿𝑠

(2.4) can be rearranged to give:

2
𝐶𝑡𝑜𝑝 𝐿𝑠 = . (2.10)
𝜔02

(2.5) can be substituted in (2.2) to give:

𝑅𝑠
𝑅𝑒 = 4 + 𝑅𝑡𝑒𝑟𝑚 .
𝜔 𝜔 2 2 (2.11)
4 (𝜔 ) − 8 (𝜔 ) + 𝜔 2 𝐶𝑡𝑜𝑝 𝑅𝑠2 + 4
0 0

At low frequencies, 𝜔 ≪ 𝜔0 , and hence 𝑅𝑒 can be approximated as 𝑅𝑙𝑜𝑤𝑓 given by:

𝑅𝑠
𝑅𝑙𝑜𝑤𝑓 ≈ + 𝑅𝑡𝑒𝑟𝑚 . (2.12)
4

At high frequencies, 𝜔 ≫ 𝜔0 , and hence 𝑅𝑒 can be approximated as 𝑅ℎ𝑖𝑔ℎ𝑓 given by:

𝑅ℎ𝑖𝑔ℎ𝑓 ≈ 𝑅𝑡𝑒𝑟𝑚 . (2.13)

At the resonant frequency, 𝜔 = 𝜔0 , and hence the peak resistance 𝑅𝑒𝑚𝑎𝑥 , as shown by the

dotted red line in Fig. 2.7, can be expressed as:

25
𝐿𝑠
𝑅𝑒𝑚𝑎𝑥 = + 𝑅𝑡𝑒𝑟𝑚 . (2.14)
2𝐶𝑡𝑜𝑝 𝑅𝑠

Given that the operating frequencies of resonant converters are easily pushed to over 500 kHz,

the presence of the parallel loop resonant peak around the typical frequency range of operation is

a reason to pay attention to this behavior. For example, the equivalent termination resistance is

more than four times higher at 700 kHz than at 1 MHz, which (a) is counterintuitive as the

termination resistance increases with switching frequency, and (b) can result in much steeper

conduction losses and lower efficiencies than expected at 700 kHz. Therefore, this phenomenon

needs to be studied in detail so that its impact on the converter efficiency can be minimized.

2.3 Impact of Filter Capacitance on the Transformer’s Termination Loss

The model assumes the capacitor to be purely reactive. However, real capacitors have parasitic

equivalent series resistances (ESRs), which could contribute to significant losses in high-output-

current applications and must also be considered in the model. Fig. 2.8 shows the modified

equivalent impedance model including the capacitor ESRs.

Fig. 2.8. Modified equivalent circuit model including capacitor ESR.

26
Adding the resistances will not impact the resonant frequency value. However, it will affect

the equivalent resistance 𝑅𝑒 as illustrated by the comparison curves in Fig. 2.9. Each 10 µF

capacitor has an ESR of 2 mΩ, and hence paralleling three of them results in a net ESR of

0.67 mΩ, which is considered in this example.

Fig. 2.9. Impact of capacitor ESR on equivalent termination resistance.

Upon considering the capacitor’s ESR, the 𝑅𝑙𝑜𝑤𝑓 , 𝑅𝑒𝑚𝑎𝑥 and 𝑅ℎ𝑖𝑔ℎ𝑓 have straightforward

modifications, resulting in 𝑅′𝑙𝑜𝑤𝑓 , 𝑅′𝑒𝑚𝑎𝑥 and 𝑅′ℎ𝑖𝑔ℎ𝑓 as shown:

𝑅𝑠 + 𝐸𝑆𝑅
𝑅′𝑙𝑜𝑤𝑓 ≈ + 𝑅𝑡𝑒𝑟𝑚 . (2.15)
4

𝑅′ℎ𝑖𝑔ℎ𝑓 ≈ 𝑅𝑡𝑒𝑟𝑚 + 𝐸𝑆𝑅, 𝑎𝑛𝑑 (2.16)

𝐿𝑠
𝑅′𝑒𝑚𝑎𝑥 = + 𝑅𝑡𝑒𝑟𝑚 . (2.17)
2𝐶𝑡𝑜𝑝 (𝑅𝑠 + 𝐸𝑆𝑅)

It can be observed from Fig. 2.9 that for a realistic ESR value, its impact on the equivalent

termination resistance is negligible up to the resonant frequency and has a slight impact thereafter.

27
Therefore, for studies focusing on frequencies at or below the resonant frequency, and where the

𝐸𝑆𝑅 ≪ 𝑅𝑠 , the ESR can be neglected in order to simplify the model and calculations.

The capacitance value selection is typically governed by the output voltage

overshoot/undershoot during load transients, and the peak-to-peak output voltage requirements at

steady state. However, from equation (2.4), the parallel resonant frequency for the parasitic

termination loop depends on the output filter capacitance 𝐶𝑡𝑜𝑝 and the loop inductance 𝐿𝑠 . For

instance, if a capacitance value is selected that satisfies both the transient and steady-state

requirements, but results in the parallel resonant frequency being in the vicinity of the switching

frequency, this will result in high termination resistance, resulting in high conduction losses, and

hence low efficiency.

Fig. 2.10 shows the equivalent termination resistance 𝑅𝑒 as a function of frequency for three

capacitance values. The transformer has sufficient winding width to accommodate three 0805-

sized capacitors each for 𝐶𝑡𝑜𝑝 and 𝐶𝑏𝑜𝑡 , and this parameter is fixed for this study.

Fig. 2.10. 𝑅𝑒 vs. frequency for different capacitors.

28
From Fig. 2.10, it can be observed that by increasing the capacitance, the parallel resonant

frequency decreases. This result indicates that, although a higher capacitance is better for the load

transient and steady-state output voltage peak-to-peak requirements, it may result in high

termination resistance as the parallel resonant frequency moves much closer to the switching

frequency.

2.4 Experimental Verification of Parallel Resonance

To experimentally verify the parallel resonance phenomenon in the terminations of center-

tapped rectifiers in planar transformers, as discussed in Section 2.3, the transformer impedance

must be measured and verified with the proposed model. However, it is practically impossible to

directly measure the secondary-winding impedance. Moreover, its magnitude is usually very low

( ≤ 1𝑚Ω ) and it is difficult to measure accurately and consistently for meaningful results.

Therefore, the transformer’s impedance is measured from the primary side for a two-fold benefit

– (a) the impedance can easily be measured across the two distinct primary winding terminals, and

(b) it is easier to capture any small differences in secondary impedance, because the high turns

ratio will reflect the small resistances of the secondary to the primary with a large gain.

However, to validate the measurement, the entire transformer must be modeled, which would

include the magnetizing inductance and the winding leakage inductances. Fig. 2.11 shows the

complete schematic for one elemental transformer, and Fig. 2.12 shows the equivalent circuit

model reflected to the primary side, where n is the turns ratio.

29
Fig. 2.11. Schematic of one elemental transformer with CT rectifiers and loop parasitics.

Fig. 2.12. Equivalent circuit model of transformer reflected to primary side.

The equivalent impedance of the transformer, 𝑍 is given by:

𝑍 = 𝑍1 ||[𝑍2 + (𝑍3 ||𝑍4 )], (2.18)

where 𝑍1 , 𝑍2 , 𝑍3 and 𝑍4 are the branch impedances shown in Fig. 2.12 and are defined as:

𝑍1 = 𝑅𝑚 + 𝑗𝜔 𝐿𝑚 , (2.19)

𝑍2 = 𝑛2 (𝑅𝑤 + 𝑗𝜔 𝐿𝑤 ), (2.20)

1
𝑍3 = 𝑛2 (𝐸𝑆𝑅 + ) , 𝑎𝑛𝑑 (2.21)
𝑗𝜔 𝐶𝑡𝑜𝑝

1
𝑍4 = 𝑛2 (𝐸𝑆𝑅 + 𝑅𝑠 + 𝑗𝜔𝐿𝑠 + ). (2.22)
𝑗𝜔 𝐶𝑏𝑜𝑡

30
Modeling the transformer also introduces magnetizing and leakage inductance branches into

the model, and these must be accounted for to fully validate the measurement. A list of different

tests to accurately measure or model the different elements in Fig. 2.12 is provided below. The

transformer impedance is measured using a Keysight 4990A impedance analyzer with the

Keysight 42941A high-bandwidth in-circuit impedance probe.

3.1 [A8][A9]𝐿𝑚 and 𝑅𝑚 : The magnetizing impedance branch 𝑍1 can be measured by setting the

secondary side to be an open circuit (OC), as shown in Fig. 2.13 (a), resulting in the

equivalent circuit model shown in Fig. 2.13 (b).

(a) (b)

(c)

Fig. 2.13. Magnetizing inductance measurement: (a) open-circuit secondary, (b) equivalent
circuit model, and (c) impedance and resistance measurement results.

31
The equivalent circuit model is modified as shown in Fig. 2.13 (b), resulting in the Z being

measured as:

𝑍 = 𝑍1 . (2.23)

From the measurement curves in Fig. 2.13 (c), the impedance curve is purely inductive up

to 1 MHz, and the magnetizing inductance can be calculated from the slope. The

magnetizing resistance is a representation of the core loss and is obtained directly from the

measurement (green curve in Fig. 2.13 (c)).

3.2 [A10]𝐿𝑘 and 𝑅𝑤 : The leakage impedance branch 𝑍2 can be measured by setting one half of

the secondary side to be a short circuit (SC) as shown in Fig. 2.14 (a), resulting in the

equivalent circuit model shown in Fig. 2.14 (b).

(a) (b)

(c)

Fig. 2.14. Leakage inductance measurement: (a) short-circuit secondary, (b) equivalent circuit
model, and (c) impedance and resistance measurement results.
32
The equivalent circuit model is modified as shown in Fig. 2.14 (b), resulting in the Z being

measured as:

𝑍 = 𝑍1 ||𝑍2 ≈ 𝑍2 𝑎𝑠 𝑍1 ≫ 𝑍2 . (2.24)

From the measurement curves in Fig. 2.13 (c), the leakage inductance can be calculated

from the slope of the impedance curve. The magnetizing resistance is a representation of

the winding loss and is obtained directly from the measurement (green curve in Fig.

2.14(c)).

3.3 Capacitance[A11] measurement: The capacitance and the ESR of the ceramic capacitors are

measured using the 16034E test fixture for surface-mounted devices (SMDs) attached to

the Keysight 4990A, as shown in Fig. 2.15 (a). The impedance measurement results for

one sample, a 25V 4.7µF X8L 0805, is shown in Fig. 2.15 (b).

(a) (b)

Fig. 2.15. (a) 16034E probe with device under test (DUT), and (b) capacitor parameter
measurement.

Three capacitors with low ESRs were tested for this study, and their results are summarized

in Table 2.1.

33
Table 2.1. Summary of selected capacitors.

Rated Voltage Measured Temperature


Package ESR (mΩ)
Capacitance (µF) Rating (V) Capacitance (µF) Coefficient
10.0 0805 25 8.6 2.0 X7S
4.7 0805 25 4.1 6.5 X8L
1.0 0805 100 0.95 4.7 X7R
3.4 [A12]𝐿𝑠 and 𝑅𝑠 : It is impractical to accurately take a physical measurement of the leakage

inductance and resistance of the termination due to their small magnitudes. Therefore,

FEA Q3D simulations are performed to simulate the termination-loop inductance 𝐿𝑠 and

resistance 𝑅𝑠 . The simulated AC 𝐿𝑠 and 𝑅𝑠 values at different frequencies are shown in

Fig. 2.16.

Fig. 2.16. Simulated AC 𝐿𝑠 and 𝑅𝑠 as a function of frequency.

The AC 𝐿𝑘 and 𝑅𝑘 vary with frequency, and since the exact parallel resonant frequency is

not known beforehand, the exact values for the AC 𝐿𝑘 and 𝑅𝑘 cannot be selected.

Therefore, an average over a realistic frequency range is taken, which in this case is

selected as 0.5 MHz – 1.5 MHz, and results in the following values:

𝐿𝑠,𝑎𝑣𝑔 = 3.1 𝑛𝐻, 𝑅𝑠,𝑎𝑣𝑔 = 4.4 𝑚𝛺. (2.25)

34
Once all the parameters are accounted for, the hardware measurement can be successfully

validated by the transformer model. Instead of the impedance, the transformer resistance is studied

because it provides a direct relationship with the transformer loss, which ultimately determines the

converter’s efficiency.

The transformer resistance was measured with the three capacitors listed in Table 2.1 mounted

as the output filter capacitors. Fig. 2.17 shows the measured transformer resistances with the three

capacitors as solid lines, and the modeled curves as the dashed lines.

Fig. 2.17. Measured and modeled equivalent transformer resistance versus frequency.

Several conclusions can be drawn from the curves:

• The model agrees well with the measurements within reasonable margin of measurement error.

• The resistance curves can be seen to have two peaks: one at a low frequency corresponding to

the parallel resonance involving the magnetizing inductance branch, and the other at a higher

frequency corresponding to that involving the parasitic-loop inductance branch.

35
• As the capacitance increases, the parallel resonant frequency and the peak resistance at the

parallel resonant frequency decrease.

• The parallel resonant frequency of the parasitic loop should be kept far away from the

converter’s switching frequency to minimize the transformer resistance, and hence transformer

loss increase. For example, when operating at 1 MHz, the measured transformer resistances

for the 10µF, 4.7µF and 1µF capacitors are 642 mΩ, 1.41 Ω and 714 mΩ, respectively. This

shows that at 1 MHz, simply by changing the output capacitance from 10 µF to 4.7 µF, the

transformer resistance, and hence the winding loss, will increase by almost 100%, which is

significant.

These results provide a general design guideline for output filter capacitor selection for planar

transformers with center-tapped rectifiers, so as to minimize the impact of the parasitic parallel

resonant peak on the transformer’s resistance at the switching frequency.

2.5 Conclusions

In this chapter, the termination design in planar matrix transformers with center-tapped

rectifiers have been studied. Advances in termination design have been reviewed, including

minimization of the termination loss by moving the secondary layers to the top and bottom PCB

layers such that the SRs and output filter capacitors can be placed directly on them.

However, this solution involves splitting the output filter capacitance between the top and

bottom layers, which results in a long parasitic path between them with significant parasitic

inductance. This inductance resonates with the parallel branch containing the filter capacitors,

resulting in resistance peaking at the parallel resonant frequency.

36
The parallel resonant frequency is dependent on the parasitic inductance and the filter

capacitance. In this study, the impact of filter capacitance on the parallel resonant frequency is

studied. With higher capacitance, the parallel resonant frequency reduces.

This concept is experimentally verified by measuring the transformer impedance and

resistance with different output capacitors. However, the entire transformer is modeled since the

impedance must be measured from the primary side. The model verifies the measurement within

experimental tolerance, and verifies the hypothesis that the transformer resistance, and hence

transformer conduction losses, are highest if the switching frequency is at the parallel resonant

frequency; hence the latter must be moved far away from the former for optimal efficiency. For

example, at 1MHz operation, either the 10µF or the 1µF capacitor may be used, but the parallel

resonant peak with the 4.7µF capacitors is right around 1 MHz, resulting in almost double the

transformer resistance.

The future scope for this work includes investigating the termination parasitic loop in detail

and attempting to minimize the loop inductance in order to push the parallel resonant frequency

further up the frequency, thereby reducing the impact of the capacitance selection on the

converter’s performance.

37
Chapter 3. Improved Symmetrical Shielding Technique

for Planar Matrix Transformers

3.1 Introduction

The planar matrix transformer with PCB windings for resonant converters has been

demonstrated to exhibit high efficiencies and high power densities, while realizing high

reproducibility and the ability to be mass-produced. However, the large cross-sectional area of the

transformer results in significant overlapping and limited distance between the primary and

secondary windings, resulting in large inter-winding parasitic capacitances between the primary

and secondary sides, as shown in Fig. 3.1[28].

(a)

(b)

Fig. 3.1. (a) Schematic of LLC converter with switching nodes, and (b) CM noise sources and
coupling paths.
38
There are four voltage pulsation nodes in the converter with high 𝑑𝑣/𝑑𝑡 – the half-bridge

switching node 𝑉𝑆𝑊 , the voltage applied to the transformer primary winding 𝑉𝑝𝑟𝑖 and the drain-

source voltages of the two SRs, 𝑉𝑆𝑅1 and 𝑉𝑆𝑅2, as shown in Fig. 3.1 (a). Fig. 3.1 (b) shows the

simplified CM noise coupling path with the lumped switching voltages. 𝑉𝑆𝑅1 and 𝑉𝑆𝑅2 are equal in

magnitude and opposite in phase, and hence cancel out each other’s CM noise. Another path for

the CM noise coupling is from 𝑉𝑆𝑊 to the primary ground through another parasitic capacitance

𝐶𝐴𝐺 . However, 𝐶𝐴𝐺 is generally much lower in magnitude than 𝐶𝑃𝑆 and hence 𝑉𝑝𝑟𝑖 dominates the

CM noise going through the transformer, since it has a path through the large inter-winding

capacitors.

The inter-winding current can be expressed as:

𝑑𝑉𝑃𝑟𝑖
𝑖 = 𝐶𝑃𝑆 . (3.1)
𝑑𝑡

To mitigate the CM noise through 𝐶𝑃𝑆 , either the 𝑑𝑉𝑃𝑟𝑖 /𝑑𝑡 can be reduced, or the propagation

path capacitance 𝐶𝑃𝑆 can be minimized or eliminated. To achieve this, the shielding technique is

commonly employed [29][30]. The idea is to introduce additional PCB layers to the transformer

between the primary and secondary layers, which can conduct the CM noise current back to the

primary side.

Fig. 3.2 shows the schematic and the modified PCB layer stack-up of the previously four-

layer PCB planar matrix transformer with shielding. One shield layer is added between each set of

primary and secondary layers, resulting in a six-layer PCB.

39
(a) (b)

Fig. 3.2. (a) LLC converter schematic, and (b) six-layer PCB stack-up.

The shield layers are placed between the primary and secondary layers and are connected to

the primary ground such that the induced CM noise from the primary is blocked by the shield and

conducted back into the primary ground, thereby isolating the secondary side. However, the

induced voltage in the shield windings act as another voltage pulse source, and hence can further

conduct current to the secondary side if not carefully designed.

(a) (b)

Fig. 3.3. Equipotential shield windings: (a) shield and secondary windings, and (b) potential
mapping across the windings.
40
The shield winding must be designed identical to the secondary winding, such that there is no

potential difference between the two, and hence no current flow. Fig. 3.3 illustrates this concept,

as the one-turn shield layer is identical to the one-turn secondary layer. The winding can be

expanded along the x-axis, along which the voltage potential can be mapped. Terminal B of the

secondary winding is connected to the secondary ground. Hence, the potential from A to B reduces

from an arbitrary V to 0. To make the shield winding identical, the B’ terminal of the shield is

connected to the primary ground, since the induced CM noise current must be sent back to the

primary side. Due to the identical structures of the two windings, the potential at terminal A’ is

also V. Since the voltage potential at each point on the two layers is identical, there is no CM noise

current going from the shield to the secondary. Moreover, the two windings remain at equipotential

even if the shield winding is rotated about its center by an arbitrary angle [29].

However, there are now two additional layers that conduct current in the planar transformer,

leading to additional losses, and hence lower efficiency. Since the induced current is low in

magnitude, typically low-weight copper is used to design the shield layers to minimize the induced

eddy currents that increase with copper weight. However, CPES recently proposed a modified

shielding technique that utilizes part of the shield windings as part of the primary windings to

improve the overall converter efficiency [31].

Fig. 3.4 shows the proposed shielding technique as part of the primary. Half the shield

windings are connected in parallel, as they have the same voltage potential at the terminals. Next,

the primary windings’ terminal connected to the primary ground is disconnected and is instead

connected to one end of the paralleled shield windings.

41
Fig. 3.4. Modified shielding technique with shielding as part of the primary.

It can be observed that, in addition to the 16 primary turns, four shield windings also carry

one-fourth of the primary current, which is equivalent to an additional primary turn. This results

in a net turns ratio of 17:1, which results in a lower primary current – and hence lower primary

device conduction loss – by around 10%. Therefore, the increase in transformer loss due to the

addition of the shield layers can be offset by the reduction in primary device conduction loss,

resulting in a negligible reduction, if not an increase, in converter efficiency.

The winding structure for the proposed shielding is shown in Fig. 3.5. The primary current

exits the primary layers and enters the Layer 2 shield, upon which it splits into the four matrix

transformers and conducts on windings alternating between the two shield layers for better

interleaving and current sharing. Finally, the primary current merges in the Layer 5 shield and

drains into the primary ground.

42
(b) (c)

(a)

(d) (e)

Fig. 3.5. PCB winding arrangement for proposed shielding: (a) transformer schematic with
proposed shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4: primary, and (e)
Layer 5: shielding.

This technique was incorporated into the existing 800W 400V/12V LLC converter running at

1 MHz. The hardware prototype is shown in Fig. 3.6. The measured CM noise and the converter’s

efficiency compared with that of the converter without shielding is shown in Fig. 3.7 (a) and Fig.

3.7 (b), respectively.

43
Fig. 3.6. Hardware prototype of 400V/12V LLC with proposed shielding.

(a) (b)

Fig. 3.7. Hardware testing results of 400V/12V LLC with proposed shielding: (a) CM noise
comparison, and (b) converter efficiency comparison.

The CM noise was reduced significantly – by up to 30 dBµV – with the proposed shielding.

Moreover, instead of sacrificing efficiency, it improved the peak efficiency from 97.6% to 97.7%

and the full-load efficiency from 97.2% to 97.4% due to the lower primary device conduction

losses because of the higher turns number.

While this work has substantial significance, a few aspects of the modified shield structure

were not studied. This chapter will investigate the impact the modified shielding has on other

aspects of the converter performance, such as current sharing and leakage-inductance symmetry,

and propose solutions to further improve the performance of the converter.

44
3.2 Current-Sharing Study in Matrix Transformers

Due to the presence of multiple output sets in parallel in the matrix transformer, it is crucial to

maintain good current sharing among them, failing which can result in lower efficiencies,

especially at heavier loads. Therefore, improving current sharing between the parallel output sets

is essential to maximizing converter efficiency. In addition to ensuring equivalent paths

(connecting wires) from the output of the transformer to the load for all output sets, the internal

transformer structure should also be investigated for any potential impedance imbalances, which

could lead to current-sharing issues.

One way to study current sharing in the matrix transformer is to study the thermal performance

of the different elemental transformers, as an output carrying higher current would be hotter.

However, this would be a suitable method only in ideal conditions, such as with no external cooling

and a perfectly symmetrical thermal camera or thermocouple positioning. Moreover, each

elemental transformer in the converter has different components in its vicinity, which means the

heat dissipated from neighboring components could affect the temperatures of the elemental

transformers. This requires a comprehensive study of the thermal resistance network for each

elemental transformer and calibration of their temperatures, which is beyond the scope of this work.

A more accurate method of studying the current sharing is to directly measure the secondary

current flowing out of each elemental transformer, but this is not a practical approach.

Alternatively, the drain-source voltages (𝑉𝐷𝑆 ) of the SRs can be measured to get an accurate

representation of the current flowing through them. Fig. 3.8 shows waveforms of interest on the

secondary side at the resonant frequency during one-half of a switching period.

45
Fig. 3.8. Waveforms of interest on the secondary side during one-half of a cycle of operation.

Fig. 3.8 plots the primary gate-source voltage (𝑉𝐺𝑆 ), the transformer secondary-side voltage

(𝑉𝑡𝑟𝑎𝑛𝑠 ), the SR drain-source voltage (𝑉𝐷𝑆,𝑆𝑅 ), the SR source-drain current (𝐼𝑆𝐷,𝑆𝑅 ), and the SR

gate-source voltage (𝑉𝐺𝑆,𝑆𝑅 ) from top to bottom. The state of the converter at different times after

the primary switch is turned off are explained in the following.

𝑡0 : The 𝑉𝐷𝑆 of the SR reaches 0 and it starts conducting through its body diode to reduce the

𝑉𝐷𝑆 to the negative of the body diode’s forward voltage (−𝑉𝑓 ).

𝑡1 : The SR channel is turned on, and 𝑉𝐷𝑆,𝑆𝑅 = −𝐼𝑆𝐷,𝑆𝑅 ∙ 𝑅𝐷𝑆,𝑜𝑛,𝑆𝑅 .

𝑡2 : The SR channel is turned off just before the current’s zero-crossing. The remaining current

conducts through the body diode, again reducing the 𝑉𝐷𝑆 of the SR to −𝑉𝑓 .

𝑡3 : The SR current goes to 0 and the body diode of the SR stops conducting. The 𝐶𝑜𝑠𝑠 of the

SR starts charging.

46
By sufficiently delaying the SRs’ turn-off instants, their drain-source voltages can be

measured, and the period between 𝑡2 and 𝑡3 can be analyzed to obtain the relative quantity of

current flowing through each elemental transformer.

Fig, 3.9 (a) and Fig. 3.9 (b) show the measured drain-source voltages of the SRs during the

turn-off instances of the two half-cycles of operation at full loads. Fig. 3.9 (c) shows the positions

of the SRs in the two secondary layers. On the top secondary layer, SR3 and SR7 operate in the

first half-cycle SRA, whereas SR2 and SR6 operate in the second half-cycle SRB. On the bottom

secondary layer, SR1 and SR5 operate in the first half-cycle SRA, whereas SR4 and SR8 operate

in the second half-cycle SRB.

[A13]

(a)

(b) (c)

Fig. 3.9. 𝑉𝐷𝑆 waveforms of SRs during the turn-off instant: (a) first half-cycle, (b) second half-
cycle, and (c) SR positions on the transformer.

47
Two observations can be made from Fig. 3.9 – (a) the body diode conduction periods in the

two half-cycles are asymmetrical, with ~110 ns and ~95 ns for the first and second half-cycle,

respectively, for the top-side SRs, and (b) the body diodes of the SRs in the bottom layer (closer

to the air gap) stop conducting before those in the top layer (away from the air gap). These issues

are critical and are studied in the subsequent sections.

3.3 Improved Current Sharing with Symmetrical Shielding

The explanation for the asymmetrical body-diode conduction periods in the two half-cycles

can be traced to the shielding design. From Fig. 3.5 (c), Fig. 3.5 (e) and Fig. 3.9 (c), it can be

observed that only one shielding layer in each leg conducts during both half-cycles[A14]. However, the

conducting SR, and hence the conducting secondary layer, alternates between the top and bottom

layers during one switching cycle. This leads to different proximities of the conducting shield layer

to the conducting secondary layer, as shown in Fig. 3.10 (a).

[A15]

(a) (b)

Fig. 3.10. Conducting layer proximities with the original shielding technique: (a) first half-cycle,
and (b) second half-cycle.

The arrows indicate the proximities between the shield and secondary layers. The dotted lines

represent the non-conducting layers, and the solid lines represent the conducting layers. To verify
48
this, 3D FEA simulations were performed, and the leakage inductances of the conducting

secondary winding in the two half-cycles are potted in Fig. 3.11.

Fig. 3.11. 3D FEA simulated leakage inductances of secondary windings with original shielding.

It can be clearly observed that the leakage inductances are asymmetrical in the two half-cycles.

This leads to different resonant periods in the two half-cycles, resulting in different secondary

currents, which was reflected by the different body-diode conduction periods in the two half-cycles

shown in Fig. 3.9.

The intuitive solution for this issue is to parallel the two shield windings in each elemental

transformer, such that the proximities between the conducting shield layer and the conducting

secondary layer are the same in both half-cycles, as shown in Fig. 3.12.

[A16]

(a) (b)

Fig. 3.12. Conducting layer proximities with the modified shielding technique: (a) first half-
cycle, and (b) second half-cycle.
49
It can be observed that when both shield windings conduct, the proximities are symmetrical

in the two half-cycles. This is verified by the 3D FEA simulations performed on the modified

transformer to calculate the leakage inductances of the conducting secondary windings in the two

half-cycles, as shown in Fig. 3.13.

Fig. 3.13. 3D FEA simulated leakage inductances of secondary windings with modified
shielding.

Fig. 3.14 shows the modified shield-winding PCB design with all the shield windings

paralleled. The primary current exits the primary windings through the black spot and enters the

Layer 2 shield winding, after which it symmetrically splits into all eight shield windings (four on

Layer 2 and four on Layer 5 through the blue vias). Finally, the split currents converge back

through the black vias in Layer 5 and drain into the primary ground.

However, when the shield windings of this improved design are simulated on FEA 3D, the

current densities are much higher than the original shield windings, as shown in the comparison in

Fig. 3.15. Moreover, the current directions in the paralleled shield windings are anti-parallel,

indicating circulating current in the shield windings. This results in a 190% increase in the shield

winding loss (1.9 W versus 0.65 W with the original shielding).

50
(b) (c)

(a)

(d) (e)

Fig. 3.14. PCB winding arrangement for improved shielding: (a) transformer schematic with
improved shielding, (b) Layer 2: shielding, (d) Layer 4: primary, and (e) Layer 5: shielding.

51
(a) (b)

(c) (d)

Fig. 3.15. 3D FEA simulated current density comparison between original and improved shield:
(a) Layer 2 shield in original shielding, (b) Layer 5 shield in original shielding, (c) Layer 2 shield
in improved shielding, and (d) Layer 5 shield in improved shielding.

(a) Layer 2 shield in improved shielding (b) Layer 5 shield in improved shielding

Fig. 3.16. Current directions in the paralleled shield windings in the improved shielding:
(a) Layer 2 shield, and (b) Layer 5 shield.

52
To understand the reason for the circulating current, the electric field distribution within the

six-layer planar transformer must be studied, as shown in Fig. 3.17.

[A17]

Fig. 3.17. Electric field distribution within the layers of a PCB transformer with CT rectifiers.

As discussed in Section 2.1, for transformers with CT rectifiers on the secondary side, the

planar transformer design that has the secondary windings on the top and bottom layers is better

in terms of termination loss. However, it has worse interleaving with the primary windings, as can

be seen from the 2D FEA simulated electric field distribution in between the PCB windings of the

planar transformer during one half-cycle. Since only one secondary layer conducts in each half-

cycle, the electric field distribution is asymmetrical within the transformer. The shield layer closer

to the conducting secondary generates eddy currents to cancel the magnetic fields from both

secondary and primary windings between which it is placed. However, the other shield layer,

which is placed between the primary windings and the non-conducting secondary winding, only

induces eddy currents from the magnetic field of the primary windings. Thus, circulating current

is induced to reduce the leakage energy difference between the two shield layers, resulting in the

high current-density and shield winding losses, as observed in Fig. 3.15.

53
The solution for this is to expose both shield windings to equal electric fields within the

transformer. To achieve this, the litz-wire concept of interleaving is implemented in the PCB

windings. Fig. 3.18 shows the modified shield-winding arrangement, where the two parallel shield

windings are interwound such that the equivalent electric field is homogeneous around both shield

layers, resulting in no circulating current.

(a) (b)

Fig. 3.18. Interwound parallel shield layers to homogenize the electric field around them: (a)
cross-section view, and (b) current flow in 3D view.

As can be observed, by employing vias, the two shield windings can be interleaved such that

the equivalent electric fields around both shield layers are symmetrical. After this modification,

the 3D FEA simulation yields normal current densities in the shield windings, as shown in Fig.

3.19. The shield winding loss is 0.6 W, which is 8% lower than the original shield winding due to

better primary current distribution across both shield windings.

54
(a) (b)

Fig. 3.19. Current density in the paralleled shield windings with interleaved shielding:
(a) Layer 2 shield, and (b) Layer 5 shield.

(b) (c)

(a)

(d) (e)

Fig. 3.20. PCB winding arrangement for improved and interleaved shielding: (a) transformer
schematic with improved shielding, (b) Layer 3: primary, (c) Layer 2: shielding, (d) Layer 4:
primary, and (e) Layer 5: shielding.
55
Fig. 3.20 shows the final PCB winding arrangement of the improved and interleaved shield

windings. The green vias on the four corners of the matrix transformer are used to interleave the

two shield windings. Although they make holes to pass through the primary windings, which are

sandwiched between the two shield windings, the current densities on the winding corners are

negligible as far as causing a significant increase in winding loss.

3.4 Impact of Transformer Airgap on Leakage Inductance

From Fig. 3.9, it can be observed that the body-diode conduction periods of SRs that are placed

on the bottom layer are lower than those placed on the top layer. This is because of the different

proximities of the two secondary layers to the transformer’s airgap. Fig. 3.21 (a) shows the cross-

section of the construction of a typical planar transformer; as shown, the airgap is situated just

outside the PCB, hence making it closer to one of the secondary layers.

The leakage inductance paths for the two secondary layers on the top and bottom layers are

shown in the transformer cross-sectional view in Fig. 3.21 (a) [32]. For the secondary winding in

the top layer, the reluctance of the leakage path is ℛ𝑐𝑜𝑟𝑒 , whereas that for the secondary winding

in the bottom layer is ℛ′𝑐𝑜𝑟𝑒 + 2ℛ𝑎𝑖𝑟 . Since air has a much high reluctance than the ferrite core,

the leakage path for the secondary layer close to the airgap has higher reluctance, and lower

leakage inductance than the secondary layer away from the airgap.- Therefore, as can be seen in

Fig. 3.21 (b), the higher leakage inductances of the secondary (also seen in the 3D FEA simulations

in Fig. 3.11) result in a lower body-diode conduction period as compared to the SRs on the top

secondary layer (Fig. 3.9), and this causes some current-sharing issues.

56
[A18]

(a) (b)

Fig. 3.21. Asymmetrical leakage inductance and current sharing with airgap on one end of
transformer: (a) leakage inductance path for secondary, and (b) 𝑉𝐷𝑆 of SRs during turn-off.

To achieve better symmetry, the airgap can be moved to the middle of the transformer leg, as

shown in Fig. 3.22 (a). By doing so, the reluctance of the leakage paths – and hence the leakage

inductance – will be more symmetrical for the top and bottom secondary layers. This results in a

significantly lower difference in the body-diode conduction periods between the SRs on the top

and bottom secondary layers, as shown in Fig. 3.22 (b).

(a) (b)

Fig. 3.22. Symmetrical fringing flux and current sharing with airgap in the middle of
transformer: (a) fringing flux with airgap in the middle, and (b) 𝑉𝐷𝑆 of SRs during turn-off.

However, moving the airgap to the middle also exposes the other PCB layers to the fringing

flux of the airgap, thereby inducing eddy currents in them, too [33]. Since the eddy current loss is

independent of load, this results in a reduction in the light-load efficiencies when a hardware
57
prototype of the 800W 400V/12V LLC converter running at 600 kHz was tested with the airgap

on one side and in the middle, as shown in Fig. 3.23.

[A19]

Fig. 3.23. Efficiency reduction when moving the airgap to the middle.

One solution for mitigating the eddy current induction in the PCB layers that occurs due to

the fringing flux of the airgap is to increase the clearance between the transformer core and the

PCB windings. However, while maintaining the same transformer footprint, doing so will reduce

the winding width correspondingly. At light and medium loads, the eddy current losses contribute

a significant percentage of the transformer loss, and hence the clearance between the transformer

core and PCB windings can be optimized to minimize the transformer loss. However, at higher

loads, the percentage of the winding losses are so high that any reduction in fringing losses from

increasing the clearance is overshadowed by the increase in winding loss due to lower winding

widths.

3.5 Hardware Verification of Efficiency Improvement

To verify the current-sharing improvement with the symmetrical shielding structure over the

previous asymmetrical shielding, a 400V/12V LLC converter was built with the improved

58
shielding technique, and the converter efficiency was compared with the previous shielding

technique, as shown in Fig. 3.24. The converters were operated at 600 kHz.

[A20]

Fig. 3.24. Efficiency improvement with improved shielding.

It can be observed that, with the better current sharing that happens with improved

symmetrical shielding, the conduction losses are lower, resulting in an improvement in full-load

efficiency by up to 0.25%, which represents a converter loss that is around 2W lower. This result

exhibits the importance of having good current sharing between the different elemental

transformers in the matrix transformer in high-current applications.

Fig. 3.25 shows the measured CM noise spectrum of the LLC converter with improved

shielding, as compared to that with previous shielding and no shielding. As the fundamental

shielding concept remains the same in the two shielding techniques, a CM noise reduction of

around 25 dBµV over most of the frequency spectrum up to 20 MHz can be achieved over the

converter with no shielding. This exhibits that, with similar shielding performance, the

symmetrical shielding can achieve higher converter efficiencies over the previous asymmetrical

counterpart.

59
Fig. 3.25. CM Noise measurement spectra.

3.6 Conclusions

This chapter has discussed the requirement for shielding in planar matrix transformers, and

reviewed the existing techniques of shielding, the most effective being one where half the shield

windings double as primary windings to increase the effective turns ratio by 1, thereby improving

efficiency.

Next, the current sharing in the matrix transformer was studied by examining the 𝑉𝐷𝑆 of the

SRs during the turn-off period. Different leakage inductances of the secondary windings in the two

half-cycles lead to different body-diode conduction periods, resulting in current-sharing issues.

This challenge was traced to the asymmetrical shielding structure, where the same shield layer

conducts in both half-cycles, which results in different proximities to the conducting secondary

windings.

This issue was addressed by paralleling the two shield windings. However, due to imperfect

interleaving in the center-tapped rectifiers, the two shield layers are exposed to different electric
60
fields in the transformer, resulting in current circulating among them. To overcome this, the litz-

wire concept was implemented on PCB windings; in this approach, the two shield layers are

interleaved and paralleled, resulting in them being exposed to the same electric field. The modified

shielding structure was shown to have symmetrical leakage inductances in the two half-cycles of

operation, resulting in much better current sharing.

Moreover, the location of the transformer airgap also affects current sharing in planar

transformers. Typically, the airgap is placed on one end of the PCB windings. However, this

approach results in an induction of eddy currents in the secondary layer closer to the airgap, in

which causes a higher leakage inductance to occur than on the secondary layer away from the

airgap. To address this, the airgap can be moved to the middle of the PCB such that both secondary

layers are exposed to equal fringing flux, resulting in symmetrical leakage inductances. However,

this also means eddy currents will be induced in the other PCB layers due to their proximity to the

airgap. This affect can be reduced by increasing the clearance between the windings and the core

leg, at a cost of lower heavy-load efficiencies due to lower winding widths at the same transformer

footprint.

Finally, to verify the improvement in current-sharing, an 800W 400V/12V LLC converter

prototype was developed, which could achieve up to 0.25% higher efficiency at full-load as

compared to the converter with the previous asymmetrical shielding. Moreover, both shielding

techniques achieve similar reduction in CM noise as compared to the converter with no shielding.

61
Chapter 4. Resonant Frequency Optimization of LLC

Converters

4.1 Introduction

As discussed in the introduction, the motivation for this thesis is to further improve the

performance of the previous CPES 400V/12V LLC converter in order to keep pace with the

performance levels of the latest technologies and with the ever-increasing demand for datacenters.

In the previous chapters, different aspects of converter performance were studied to improve the

converter’s efficiency, including termination design optimization and a design that achieves

improved current-sharing with symmetrical shielding. This chapter will address another aspect of

converter performance optimization – the switching frequency.

For LLC converters, such as this one, operating as unregulated DC-DC transformers, the

converter switches exclusively at the resonant frequency, at which point the converter efficiency

is at its maximum. In all the previous work that CPES did on the 400V/12V LLC converter, the

switching frequency was fixed to 1 MHz in order to exhibit the high-frequency operability and

high power densities of the converter.

However, the various losses in the converter, such as the device losses and the transformer

losses, are highly dependent on the switching frequency. As shown in Fig. 4.1, the device turn-off

loss, the gate driving loss and the conduction losses all increase with frequency. Moreover, the

transformer’s winding losses also increase with frequency, since the winding AC resistance and

the winding currents increase with frequency [34]. However, the transformer’s core loss decreases

with increasing frequency, as Fig. 4.1 shows in the core loss of the ML-91s material at fixed

62
voltage excitation. Lower core losses at higher frequencies allow the transformer size to be shrunk,

which is the main motivation behind pushing for higher frequencies.

[A21] [A22]

(a) (b) (c)

Fig. 4.1. Converter losses that increase with switching frequency: (a) device switching loss, (b)
device conduction loss, and (c) transformer winding loss.

Fig. 4.2. Transformer core loss decreases with switching frequency.

There is clearly a tradeoff between the different losses in the converter with changes in

frequency. Moreover, for low-voltage, high-current applications such as this one, the losses that

increase with frequency (conduction losses) outweigh the one that decreases with frequency (core

loss), as seen in the converter loss breakdown at 1 MHz in Fig. 4.3. The red bars show the losses

that increase with switching frequency and the blue bar shows the loss that decreases with

switching frequency. Clearly, for such applications, the switching frequency must be optimized to

maximize the efficiency, while also studying the impact on power density.

63
[A23]

Fig. 4.3. Loss breakdown of 400V/12V LLC converter at 1 MHz.

In this chapter, the switching frequency for the 400V/12V LLC converter is optimized. Core

loss densities of different ferrite materials are evaluated, and a material selection guideline is

provided. Finally, the converter’s loss and power density are evaluated at different frequencies,

and the optimal frequency is selected. The performance improvement is showcased with hardware

results at the optimized frequency.

4.2 Optimal Ferrite Material Selection at Different Frequencies

Fig. 4.4 shows the flowchart for optimizing the switching frequency of the LLC converter.

[A24]

Fig. 4.4. Flowchart showing switching-frequency optimization process.

64
The first step is to select the best ferrite material at the selected switching frequency. Typically,

Mn-Zn ferrite materials are used to design the transformer cores in high-frequency applications

[35]. Companies design using different materials, which are then recommended to be operated at

a specific frequency range for optimal performance. Among those, the ferrite material with the

lowest core loss density is typically selected for the transformer design. The core loss density 𝑃𝑣

is given by the popular Steinmetz equation:

𝛽
𝑃𝑣 = 𝑘 ∙ 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠𝛼 , (4.1)

where 𝐵𝑚𝑎𝑥 is the peak magnetic flux density in the core, 𝑓𝑠 is the switching frequency, and 𝛼, 𝛽,

and 𝑘 are the Steinmetz coefficients that are uniquely defined for each material. Moreover, 𝐵𝑚𝑎𝑥

can be defined as:

𝑇𝑠
∫02 𝑣0 𝑑𝑡 𝑉𝑜 (4.2)
𝐵𝑚𝑎𝑥 = = ,
2 𝑛 𝐴𝑒 4 𝐴𝑒 𝑓𝑠

where 𝑣0 is the instantaneous output voltage, 𝑛 is the turns ratio, 𝐴𝑒 is the cross-sectional area of

the core, and 𝑇𝑠 is the switching period.

Combining (4.1) and (4.2), 𝑃𝑣 can be written as a function of 𝑓𝑠 , as follows:

𝑉𝑜 𝛽 𝛼−𝛽
𝑃𝑣 = 𝑘 ∙ ( ) ∙ 𝑓𝑠 . (4.3)
4𝐴𝑒

Generally, 𝛽 > 𝛼 for ferrite materials, which results in a reduction in core loss density with

increases in frequency. Also, 𝛼 − 𝛽 determines the degree to which the core loss density decreases

with increases in frequency.

65
The materials datasheets typically provide average Steinmetz coefficients for different

frequency ranges, but this results in some unanswered questions, leading to the motivation to

experimentally measure the core loss densities.

To demonstrate this, the 3F3 material from Ferroxcube can be used as an example. Table 4.1

shows the Steinmetz coefficients provided in its datasheet, where different coefficients are

provided for different frequency ranges.

Table 4.1. Steinmetz coefficients for 3F3 from datasheet.

Switching Frequency (kHz) K 𝛽 𝛼


200 – 400 2.2 x 10-6 2.6 2
400 – 700 6.5 x 10-9 2.45 2.42

It can be observed that from 200 kHz – 400 kHz, 𝑃𝑣 ∝ 𝑓𝑠−0.6 , which means increasing the

frequency within this range will be beneficial toward reducing the core loss density. Moreover,

from 400 kHz – 700 kHz, 𝑃𝑣 ∝ 𝑓𝑠−0.03 , which means that in this frequency range, increasing the

frequency has negligible impact on the core loss density, hence negating any benefits of doing so.

However, from the average Steinmetz coefficients provided in the datasheets, it is impossible to

pinpoint the exact frequency at which frequency will stop impacting core loss density.

Another discrepancy can be observed from the Steinmetz coefficients provided in the

datasheet for ML-91s from Hitachi metals. Table 4.2 shows different coefficients provided for

different frequency ranges.

Table 4.2. Steinmetz coefficients for ML-91s from datasheet.

Switching Frequency (MHz) K 𝛽 𝛼


0.5 – 1 2.02 x 10-7 3.553 2.241
1–3 2.067 x 10-11 3.077 2.784

66
The 𝑃𝑣 calculated at 1 MHz (and 𝐵𝑚𝑎𝑥 = 80𝑚𝑇, a typical design point) using the first and

second sets of coefficients results in 𝑃𝑣 = 714 𝑘𝑊/𝑚3 and 𝑃𝑣 = 441 𝑘𝑊/𝑚3 , respectively, a

significantly large 62% difference. Therefore, it is difficult to determine the exact core loss density

at the boundary frequencies defined by the datasheets.

These reasons led to the requirement to experimentally measure the core loss densities of

various materials to accurately characterize them at different frequencies. Different Mn-Zn ferrite

materials with low core loss densities (according to their datasheets) are selected for testing, as

summarized in Table 4.3.

Table 4.3. Mn-Zn ferrite materials selected for core loss testing.

Recommended Range Material Manufacturer


Low Frequency 3C98 Ferroxcube
(𝑓𝑠 < 400𝑘𝐻𝑧) ML27D Hitachi
ML95s Hitachi
Medium Frequency
3F36 Ferroxcube
(400𝑘𝐻𝑧 < 𝑓𝑠 < 800𝑘𝐻𝑧)
P53 ACME
ML91s Hitachi
High Frequency
DMR-51W DMEGC
(𝑓𝑠 > 800𝑘𝐻𝑧)
P63 ACME

The core loss densities are measured using toroidal cores, such that there is uniform magnetic

flux throughout the core. The two-winding method with capacitive cancelation and partial

cancelation concept is used to measure the core loss densities [36][37].

The core loss densities of all the materials are measured at room temperature at different 𝐵𝑚𝑎𝑥

and at different 𝑓𝑠 , resulting in numerous curves. To make the characterization and comparison

significantly simpler and more straightforward, the performance factors of different materials are

evaluated [38][39]. The physical significance of this parameter can be understood from the

following equations:
67
𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠 𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠
𝑃𝑣 = = , (4.4)
𝑉𝑜𝑙𝑢𝑚𝑒 𝐴𝑒 ∙ 𝑙

where 𝑙 is the mean path length for the magnetic flux. 𝐴𝑒 can then be expressed as:

𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠 (4.5)


𝐴𝑒 = .
𝑃𝑣 ∙ 𝑙

Rearranging (4.2) to move 𝑓𝑠 to the left-hand side (LHS),

𝑉𝑜
𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 = . (4.6)
4 𝐴𝑒

Substituting 𝐴𝑒 from (4.5) into (4.6) yields

𝑉𝑜 ∙ 𝑃𝑣 ∙ 𝑙 1
𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 = . (4.7)
4 𝐶𝑜𝑟𝑒 𝑙𝑜𝑠𝑠

The term on the LHS can be defined as the performance factor, ℱ, as:

ℱ = 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠 . (4.8)

It can be observed from (4.7) that for a fixed core loss density and effective path length (core

size), a material with higher performance factor will result in a lower core loss while achieving the

same output voltage.

Based on this, the performance factors of the different materials were calculated and plotted

against the switching frequency at a fixed 𝑃𝑣 = 0.5𝑊/𝑐𝑚3 , which is the typically observed value

for this application, as shown in Fig. 4.5.

68
Fig. 4.5. Performance factors of ferrite materials at 𝑃𝑣 = 0.5𝑊/𝑐𝑚3 .

The frequencies for the different materials were pushed until the performance factor curves

started plateauing, as can be seen in the curves for ML27D and ML91s in Fig. 4.5. The frequency

was swept from 100 kHz – 2 MHz and the eight listed materials were tested in the relevant

frequency ranges. Based on the performance factor curves, the materials with the highest

performance factors at each frequency can be traced as shown by the yellow dotted line in Fig. 4.5

and as summarized in Table 4.4.

Table 4.4. Summary of materials with highest performance factors.

Frequency Range (kHz) Material with Highest Performance Company


Factor
100 – 300 ML27D Hitachi
400 – 600 ML95s Hitachi
700 – 1500 ML91s Hitachi
>1500 P63 ACME

It may be noted that the ferrite materials from Hitachi Metals perform significantly better

than those from other companies.

69
To generalize this study to other applications with different core loss densities, the

performance factors at 𝑃𝑣 = 0.3𝑊/𝑐𝑚3 and 𝑃𝑣 = 0.7𝑊/𝑐𝑚3 were also calculated and plotted

against frequency, as shown in Fig. 4.6.

(a) (b)

0.3𝑊
Fig. 4.6. Performance factor comparison at different core loss densities: (a) 𝑃𝑣 = , and (b)
𝑐𝑚3
𝑃𝑣 = 0.7𝑊/𝑐𝑚3 .

It can be observed that, even within a wide range of core loss densities, the relative

performance factors of the materials are largely similar. This means that for other applications with

different core loss densities, the results from this study can be used as a design guideline for

transformer core material selection.

4.3 Resonant Converter Performance Evaluation

Once the best-performing ferrite materials have been chosen, the converter loss is calculated

at different frequencies. The switching frequency is swept from 200 kHz – 1.6 MHz. The loss of

the matrix transformer shown in Fig. 4.7 is calculated using the same method as used in [18], as

summarized below.

70
Since the transformer voltage is rectangular, the core loss expression is modified as given in

[40]:

8 𝛽
𝑃𝑣 = ∙ 𝑘 ∙ 𝐵𝑚𝑎𝑥 ∙ 𝑓𝑠𝛼 , 𝑎𝑛𝑑 (4.9)
𝜋2

𝑃𝑐𝑜𝑟𝑒 = 𝑃𝑣 ∙ 𝑉𝑜𝑙𝑐𝑜𝑟𝑒 , (4.10)

where the 8/𝜋 2 term is included to account for the rectangular transformer voltage, 𝑃𝑐𝑜𝑟𝑒 is the

core loss, and 𝑉𝑜𝑙𝑐𝑜𝑟𝑒 is the core volume.

The transformer winding DC resistance is given by:

𝜌 ∙ 2𝜋 𝑛2 (4.11)
𝑅𝐷𝐶 = ∙ ,
ℎ 𝑙𝑛(𝑐 + 𝑟) − 𝑙𝑛 𝑟

where ℎ is the PCB layer thickness (copper weight), 𝜌 is the resistivity of copper, 𝑛 is the turns

ratio, 𝑐 is the winding width, and 𝑟 is the core radius.

The AC resistance coefficient 𝐹𝑅 is defined by the eddy current model described in [34] as:

(𝑚2 − 1) ′ (4.12)
𝐹𝑅 = 𝑀′ + 𝐷,
3

where 𝑀′ and 𝐷′ are the real parts of 𝑀 and 𝐷 , respectively; and 𝑀 = 𝛼ℎ coth(𝛼ℎ) , 𝐷 =

2𝛼ℎ tanh (𝛼ℎ/2), 𝛼 = √𝑗𝜔𝜇0 𝜂/𝜌, 𝜂 = 𝑁𝑙 𝑎/𝑏, 𝑚 is number of layers in a winding porting, 𝜔 is

angular frequency, ℎ is winding copper thickness, 𝑁𝑙 is the number of turns per layer 𝑎 is the total

winding area width, and 𝑏 is the winding width for each turn. The winding AC resistance can then

be defined as:

71
𝑅𝐴𝐶 = 𝐹𝑅 ∙ 𝑅𝐷𝐶 . (4.13)

From (4.12), it can be noted that the AC resistance is dependent on copper thickness ℎ and

switching frequency 𝜔/2𝜋. The optimal copper thickness is where the winding AC resistance is

at its minimum. Hence, the AC resistances are calculated and plotted as a function of ℎ at different

frequencies, as shown in Fig. 4.7.

[A25]

Fig. 4.7. Copper thickness optimization at different frequencies.

Fabricating PCBs with greater than 3oz Cu is very expensive, and given the diminishing

returns with higher copper weights, 3oz Cu is set as the maximum thickness. For the primary

windings, for 𝑓𝑠 < 1𝑀𝐻𝑧, 3oz Cu is selected as the optimal thickness, and for 𝑓𝑠 ≥ 1𝑀𝐻𝑧, 2oz

Cu is selected as the optimal thickness. For the secondary windings, 3oz Cu is selected as the

optimal thickness at all frequencies.

The winding loss can then be simply calculated as:

2
𝑃𝑤𝑖𝑛𝑑𝑖𝑛𝑔 = 𝑅𝐴𝐶 ∙ 𝐼𝑟𝑚𝑠 , (4.14)

where 𝐼𝑟𝑚𝑠 is the transformer rms current.

72
The total transformer loss is the sum of the core and winding losses:

𝑃𝑡𝑟𝑎𝑛𝑠𝑓𝑜𝑟𝑚𝑒𝑟 = 𝑃𝑐𝑜𝑟𝑒 + 𝑃𝑤𝑖𝑛𝑑𝑖𝑛𝑔 . (4.15)

Fig. 4.8. Matrix transformer dimensions.

From Fig. 4.8, the transformer footprint can be calculated as:

𝐹𝑃 = 𝑊 2 = (4𝑟 + 4𝑐)2 . (4.16)

[A26]

Fig. 4.9. Transformer loss optimization.

73
Fig. 4.9 shows transformer loss contours plotted at different core radii and winding widths at

a frequency of 1 MHz. The dotted lines are the transformer’s footprint contours. The knee-point

in each loss contour, shown by the red dot, corresponds to a footprint contour, which is the

minimum footprint required to realize that loss. Hence, at each transformer footprint, the minimum

transformer loss can be achieved solely with a unique 𝑟 and 𝑐 combination (red dot). This also

demonstrates the tradeoff between the core loss and the winding loss, where a higher 𝑟 results in

a lower core loss, but a higher 𝑐 results in a lower winding loss.

This process is repeated for different frequencies and the minimum transformer losses can

then be traced out and plotted against the transformer footprint, as shown in Fig. 4.10.

Fig. 4.10. Minimum transformer loss vs. transformer footprint.

It can be intuitively observed that the transformer loss reduces with as the transformer

footprint grows. However, there are diminishing returns upon increasing the footprint, and the

footprint design point must be chosen at the knee point of the curve for optimal performance.

74
However, since this application is restricted by the quarter-brick form factor, the design region is

chosen around the 1200 mm2 footprint region, which is also around the knee points of the curves.

The optimal 𝑟 and 𝑐 values at 1200 mm2 footprint at various switching frequencies are listed

in Table 4.5.

Table 4.5. Optimal transformer dimensions.

Frequency (kHz) Core Radius, 𝑟 (mm) Winding Width, 𝑐 (mm) 𝑟/𝑐


200 4.9 3.4 1.45
600 3.75 4.6 0.8
1000 3.45 4.9 0.7
1400 2.9 5.4 0.55

The core radius to winding width ratio indicates the ratio of the core loss to winding loss in

the transformer. As the frequency increases, the winding loss increases and the core loss decreases,

hence resulting in a decrease in the r/c ratio.

Finally, the total converter loss for the 1kW 400V/12V LLC converter at different switching

frequencies needs to be evaluated. Fig. 4.11 shows the transformer loss at a footprint of 1200 mm2,

with device loss and total converter loss plotted against the switching frequency of the converter.

75
Fig. 4.11. Different converter losses as a function of resonant frequency.

The different regions show the different ferrite materials used at different frequencies. It must

be noted that the maximum magnetic flux density 𝐵𝑚𝑎𝑥 for the ML91s material was restricted to

80 mT based on its material requirements. The transformer loss increases with frequency with the

same material, as the increase in winding loss is higher than the reduction in core loss. However,

the transformer loss reduces at the frequencies when the core material changes, as switching to a

better material results in lower core loss.

In addition to the converter loss, the converter power density must also be studied to

completely analyze the impact switching frequency has on the converter’s performance. Since the

transformer, and hence, converter footprint, are fixed at all frequencies, the power density is

dependent on the transformer’s core profile. The plate thickness is calculated such that there is

uniform magnetic field distribution throughout the transformer. Fig. 4.12 shows the magnetic flux

density in the core legs and plates.

(a) (b)

Fig. 4.12. Magnetic flux density in the transformer: (a) top view, and (b) cross-sectional view.

76
The magnetic flux density in the plates is half of that in the core legs. Therefore, for uniform

magnetic field in the transformer,

𝜙 𝜙/2 (4.17)
= ,
𝐴𝑙𝑒𝑔𝑐𝑜𝑟𝑒 𝐴𝑝𝑙𝑎𝑡𝑒 𝑒𝑓𝑓

where 𝜙 is the magnetic flux density in the core legs, 𝑐 is the cross-section area of the core leg,

and 𝐴𝑝𝑙𝑎𝑡𝑒 𝑒𝑓𝑓 is the effective cross-section area of the plate. Solving (4.17), the required plate

thickness ℎ𝑝𝑙𝑎𝑡𝑒 is given by:

𝜋𝑟 2 (4.18)
ℎ𝑝𝑙𝑎𝑡𝑒 = .
2𝑟 + 𝑐

From Table 4.5, 𝑟 decreases and 𝑐 increases with increases in frequency. This results in a

decrease in plate thickness with increases in frequency, resulting in higher power density with

increases in frequency.

Fig. 4.13 shows the converter’s full-load efficiency versus power density at different

switching frequencies.

[A27]

Fig. 4.13. Full-load efficiency versus power density at different frequencies.

77
The previous CPES converter’s performance is shown by the yellow dot. The curve behaves

as expected – there is a tradeoff between converter efficiency and power density with changes in

switching frequency. When the frequency is reduced from 400 kHz, there is a diminishing return

in efficiency improvement. Moreover, when the frequency increases from 800 kHz, the efficiency

drops very quickly owing to the high conduction and winding losses at higher frequencies. Hence,

a sweet spot for converter design can be set between 400 kHz and 800 kHz. Based on the design

requirements, either the converter efficiency or the power density can be prioritized, and the

corresponding switching frequency can be selected to optimize converter design.

4.4 Hardware Verification of Proposed Performance Improvement

To demonstrate the increase in efficiency compared to the previous CPES converter, a 1kW

400V/12V LLC converter running at 400 kHz was designed. Fig. 4.14 shows the hardware

prototype of the LLC converter.

[A28]

Fig. 4.14. Hardware prototype of proposed converter.

The converter dimensions are 58 mm x 37 mm x 8.1 mm, resulting in a power density of 940

W/in3. This is higher than the previous CPES converter even after operating at lower frequencies

due to the higher rated power. Thermally, it is difficult to push more than 800 W (with air cooling

78
and no heat sinks) at 1 MHz operation due to the high device and transformer temperatures that

occur because of high conduction losses. However, at a lower frequency of 400 kHz, the device’s

conduction losses are much lower, which allows the rated power to be increased, while being

thermally sound.

Table 4.6 shows the specifications of the proposed converter, compared with that of the

previous CPES converter.

Table 4.6. Specifications of the proposed LLC converter.

Component Previous CPES This Work


Rated Power 800 W 1 kW
Resonant Frequency 1 MHz 400 kHz
Dead Time 90ns 125 ns
Transformer Turns Ratio 16:1 16:1
Primary Devices PGA26E08 80 mΩ GaN
Secondary Devices BSC0500NSI BSZ0500NSI
Primary Driver Si8273 Si8273
Secondary Drivers FAN3122 FAN3122
Shielding Technique Asymmetrical Symmetrical
Output Filter Capacitance Per Leg 6 x 10 µF 6 x 10 µF
Resonant Capacitor 71 nF 287 nF
Resonant Inductance 312 nH 478 nH
Magnetizing Inductance 25 uH 80 µH
Transformer Footprint 1200 mm2 1200 mm2
Core Radius 3.5 mm 4.5 mm
Winding Width 4.9 mm 3.9 mm
Power Density 900 W/in3 940 W/in3

The resonant frequency is reduced to 400 kHz as optimized in the previous section. The

leakage inductance, which is used as the resonant inductance, is 478 nH. The resonant capacitance

is then accordingly set such that the resonant frequency equals the switching frequency. The

magnetizing inductance and the dead time are optimized according to the methodology in [15] to

result in 80 µH and 125 ns, respectively. The primary device is replaced with a new GaN device

with lower turn-off energy. Due to lower winding width, the SR is replaced with a BSZ0500NSI,

79
as it has a smaller package that can fit on the winding. Based on the output filter capacitor selection

guideline proposed in Chapter 1, the 10µF capacitors are still the best choice for operation at 400

kHz, and hence are used in this converter. Moreover, based on the study in Chapter 2, the

symmetrical shielding technique is employed in this woek.

Fig, 4.15 shows the operating waveforms at light load (10%) and at full load (1kW).

(a)

(b)

Fig. 4.15. 400V/12V LLC converter operating waveforms: (a) light load (10%, 100 W), and (b)
full load (100%, 1 kW).

It can be observed that zero-voltage switching (ZVS) is achieved at both light load and full

load. Moreover, there is no ringing in the secondary VDS voltage due to minimum secondary

leakage.

80
The thermal performance of the LLC converter running at full load (1kW) for around 2

minutes until thermal steady state is shown in Fig. 4.16. The converter is air-cooled with 400 linear

feet per minute (LFM) from left to right. The maximum temperature on the converter is around

94 0C at the primary devices, with the SRs and transformer core showing maximum temperatures

of 91 0C and 53 0C respectively.

Fig. 4.16. Thermal performance of LLC converter.

Fig. 4.17 shows the measured efficiencies of the converter, compared with that of the previous

CPES converter. Moreover, the dashed efficiency curve shows the calculated efficiency, which

follows the actual measurement closely, hence validating the accuracy of the frequency

optimization model.

81
[A29]

Fig. 4.17. 400V/12V LLC converter efficiency.

The converter can achieve 95% light-load efficiency (10% load), 98.15% peak efficiency (at

around 500W), and 97.5% at full load (1 kW). Due to better devices and lower switching losses at

lower frequencies, the light-load efficiency increases by 2.4% despite an increase in the core loss.

The peak- and full-load efficiencies also increase by 0.6% and 0.2%, respectively, due to the lower

device conduction and transformer winding losses. This can be quantitatively observed from the

converter loss breakdown comparison in Fig. 4.18.

[A30]

Fig. 4.18. Comparison of the converter loss breakdown at full load.

82
Therefore, the hardware results verify the performance improvement of the 1kW 400V/12V

LLC converter operating at 400 kHz by illustrating that its efficiency and power density are higher

than the previous CPES 800W 400V/12V LLC converter operating at 1 MHz.

4.5 Conclusions

In this chapter, the resonant frequency, at which the 400V/12V LLC converter switches

exclusively, is optimized to improve the performance over the previous CPES 400V/12V LLC

converter. The different components of the converter loss depend heavily on the switching

frequency, and hence it is vital to optimize it to maximize the performance of the converter.

The selection of the best ferrite material for the transformer core at different frequencies is

vital for minimizing the transformer loss. To achieve this, the core loss densities of different

materials were measured, their performance factors were evaluated at a fixed core loss density as

a function of frequency, and the materials with the highest performance factors were selected. To

generalize the study to other applications with different core loss density values, the relative

performance factors were shown to be similar at different core loss densities, too.

After selecting the core materials, the transformer loss was evaluated at different switching

frequencies. The optimal copper weights for the primary and secondary PCB layers were

calculated. For the primary layers, 3oz Cu is recommended for 𝑓𝑠 < 1𝑀𝐻𝑧 and 2oz Cu is

recommended for 𝑓𝑠 ≥ 1𝑀𝐻𝑧 . For the secondary layers, 3oz Cu is recommended for all

frequencies. The optimal transformer dimensions are selected based on the tradeoff between core

loss and winding loss, and the minimum transformer loss at different transformer footprints are

evaluated, where 1200 mm2 is selected as the design region. Finally, the converter efficiency and

the power densities at different frequencies are evaluated, where there is a tradeoff between the

83
two with changes in frequency. Upon studying the curve, 400 kHz – 800 kHz is recommended as

the switching frequency design region.

To demonstrate the efficiency improvement, a 1kW 400V/12V LLC converter running at 400

kHz was built and tested. It is able to achieve 95% and 97.5% efficiencies at a light load and at a

full load, respectively, while achieving a peak efficiency of 98.15%, all of which are higher than

those of the previous CPES converter. Moreover, the power density was 940 W/in3, also higher

than the previous CPES power density, due to the higher-rated power, despite its higher

transformer profile.

Chapter 5. Summary and Future Work


With the ever-increasing demand for internet services, the energy demand from datacenters is

also rising exponentially. This is leading to improvements in datacenter power architectures, with

the 400V-bus architecture showing the greatest promise for the future. This, however, requires

stepping down 400 V directly to 12 V on the server motherboard, requiring high efficiency and

power density from the 400V/12V DC-DC converter. CPES has done considerable work in this

field, with the latest converter achieving 97.6% peak efficiency and 900 W/in3. However, extensive

research by other groups is closing the performance gap to the CPES converter, leading to the

motivation of this thesis, which is improving the performance of the previous CPES 400V/12V

LLC converter.

The second chapter studies the termination design of planar matrix transformers with center-

tapped rectifiers. The SRs and output filter capacitors are placed on the secondary windings to

minimize the termination inductance. However, the output filter capacitors are split between the

top and bottom secondary layers, resulting in a long parallel path between the two. This parallel
84
loop has a parasitic inductance that resonates with the capacitance to cause a parallel resonance

peak in the transformer’s impedance curve. This parallel resonant frequency must be kept far away

from the converter resonant frequency to minimize its impact on the transformer’s AC resistance,

and hence, converter efficiency. The chapter proposed a capacitance selection guideline to achieve

this goal.

In addition to selecting a suitable capacitance, the loop inductance value itself can be

minimized by optimizing the termination loop. If the loop inductance is sufficiently small, the

parallel resonant frequency should be high enough to not impact the impedance at the switching

frequency, irrespective of the capacitance. This will be investigated in the future.

Chapter 3 investigates the shielding technique in planar matrix transformers, which is crucial

for minimizing the high CM noise. CPES previously proposed a shielding technique that uses half

of the shielding turns as part of the primary windings in order to increase the turns ratio by 1,

thereby reducing the primary-device conduction losses to offset the loss increase from adding two

extra layers. However, upon studying the drain-source voltages of the SRs, current-sharing issues

were detected, which were traced to the asymmetrical design of the shield and the position of the

transformer airgap. The shield windings were made symmetrical by conducting all the shield

windings in parallel, and by interleaving the two layers on the same elemental transformer. This

resulted in a 0.25% converter efficiency improvement due to better current sharing in the two half-

cycles of operation.

The transformer airgap location also affects leakage inductance, and hence the current sharing

between the two secondary layers. The airgap can be moved to the center to make the leakage

inductances symmetrical, but this induces eddy currents in the other windings due to their

85
proximity with the airgap, resulting in reduction in light-load efficiency. In the future, other

possible solutions may be investigated to tackle this issue with minimum tradeoffs.

Chapter 4 discusses the switching frequency optimization for the LLC converter. First, the

core loss densities of different materials were measured, their performance factors were evaluated

at a fixed core loss density as a function of frequency, and the materials with the highest

performance factors were selected. Based on this, the converter loss and the power densities were

calculated at different frequencies, where there is a tradeoff between the two with changes in

frequency. Upon studying the curve, 400 kHz – 800 kHz is recommended as the switching

frequency design region.

Combining the results from all the chapters, a 1 kW 400V/12V LLC converter operating at

400 kHz with symmetrical shielding and 10 µF output filter capacitors was developed. The

performance of this converter can be updated from Table 1.3, resulting in Table 5.1.

Table 5.1. Updated performance summary of recent 400V/12V unregulated DC-DC converters.

ITEM [18] [20] [21] [22] [23] [24] This Work


Rated Power (W) 800 1000 800 1800 800 1000 1000
Frequency (MHz) 1 1 1 1 1 1 0.4
Peak Efficiency (%) 97.6 97* 96.5* 98.3* 97.4 97.3 98.15
Power Density
900 640** 900** 810 1177 - 940
(W/in3)
* Without Driving Loss ** Without Controller

It can be observed that the performance of this work is exemplary as compared to the others

described in this study. The efficiency comparisons with the previous CPES work and other works

of similar power levels are shown in Fig. 5.1.

86
[A31]

Fig. 5.1. Converter efficiency comparison with other works.

The converter’s power density can be further pushed if the rate power can be further pushed,

while maintaining the same converter dimensions. However, the thermal performance needs to be

further improved to achieve this end, as simply air-cooling is not sufficient to safely run the

converter at higher loads. This is an interesting topic for future work.

87
References
[1] N. Jones, "How to stop data centres from gobbling up the world’s electricity," Nature, vol.
561, 2018, pp.163-166.

[2] A. S. G. Andrae, T. Edler, “On global electricity usage of communication technology: trends
to 2030”, Challenges, Vol. 6, 2015, pp. 117-157.

[3] A. Pratt, P. Kumar, and T. V. Aldridge, “Evaluation of 400 V DC distribution in telco and
data centers to improve energy efficiency,” in Proc. IEEE 29th Int. Telecommun. Energy
Conf., 2007, pp. 32–39.

[4] D. J. Becker and B. J. Sonnenberg, "400Vdc power distribution: Overcoming the


challenges," Intelec 2010, 2010, pp. 1-10.

[5] Vicor white paper, “From 48V direct to Intel VR12.0: Saving ‘Big Data’ $500000 per data
center, per year,” July 2012, [online]:
http://www.vicorpower.com/documents/whitepapers/wp_VR12.pdf.

[6] D. Kim, J. He, and D. G. Figueroa, “48V Power Delivery to Grantley Reference Board,”
2016.

[7] US Energy Information Administraton, “How much electricity does a nuclear power plant
generate?”, Dec. 2020, [online]: https://www.eia.gov/tools/faqs/faq.php?id=104&t=33.

[8] G. AlLee and W. Tschudi. “Edison redux: 380 Vdc brings reliability and efficiency to
sustainable data centers.” IEEE Power and Energy Magazine, vol. 10, no.6, Oct. 2012, pp.
50-59.

[9] S. M. Lisy, B. J. Sonnenberg and J. Dolan. “Case study of deployment of 400V DC power
with 400V/-48VDC conversion,” In Proc. IEEE INTELEC 2014, pp. 1-6.

[10] International Electronics Manufacturing Initiative, “iNEMI Statement of Work (SOW) DC-
DC Power Module, Phase 2,” May 2015 [Online]:
http://thor.inemi.org/webdownload/2015/SOW_DCDC_Power_Module_Phase2_050115.p
df.

88
[11] J. G. Cho, J. A. Sabate, G. Hua, and F. C. Lee. "Zero-voltage and zero-current-switching full
bridge PWM converter for high-power applications." Power Electronics, IEEE Transactions
on 11, no. 4 (1996): 622-628.

[12] W. Chen, P. Xu, and F. C. Lee. "The optimization of asymmetric half bridge converter." In
Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual
IEEE, vol. 2, 2001, pp. 703-707.

[13] Y. Liu. "High efficiency optimization of LLC resonant converter for wide load range." M.S.
thesis, Virginia Polytechnic Institute and State University, 2007.

[14] B. Yang, F. C. Lee, A. J. Zhang, and G. Huang. "LLC resonant converter for front end
DC/DC conversion." In Applied Power Electronics Conference and Exposition, 2002. APEC
2002. Seventeenth Annual IEEE, vol. 2, 2002, pp. 1108-1112.

[15] B. Lu, W. Liu, Y. Liang, F. C. Lee, and J. D. Van Wyk. "Optimal design methodology for
LLC resonant converter." In Applied Power Electronics Conference and Exposition, 2006.
APEC'06. Twenty-First Annual IEEE, 2006, pp. 6.

[16] D. Huang, S. Ji and F. C. Lee, "LLC Resonant Converter With Matrix Transformer," in IEEE
Transactions on Power Electronics, vol. 29, no. 8, Aug. 2014, pp. 4339-4347.

[17] M. Mu and F. C. Lee, "Design and Optimization of a 380–12 V High-Frequency, High-


Current LLC Converter With GaN Devices and Planar Matrix Transformers," in IEEE
Journal of Emerging and Selected Topics in Power Electronics, vol. 4, no. 3, Sept, 2016, pp.
854-862.

[18] C. Fei, F. C. Lee and Q. Li, "High-efficiency high-power-density LLC converter with an
integrated planar matrix transformer for high-output current applications," IEEE Trans. on
Industrial Electronics, vol. 64, no. 11, Nov. 2017, pp. 9072-9082.

[19] D. Reusch and F. C Lee, “High frequency bus converter with low loss integrated matrix
transformer,” in Proc. IEEE APEC 2012, pp. 1392–1397.

[20] Y. -C. Liu, K. -D Chen, C. Chen, Y. -L. Syu, G. -W. Lin, K. A. Kim and H. -J. Chiu,
"Quarter-turn transformer design and optimization for high power density 1-MHz LLC
resonant converter," IEEE Trans. on Industrial Electronics, vol. 67, no. 2, Feb. 2020, pp.
1580-1591.
89
[21] Y. -C. Liu, C. Chen, K. -D. Chen, Y. -L. Syu, D. -J. Lu, K. A. Kim and H. -J. Chiu, "Design
and implementation of a planar transformer with fractional turns for high power density LLC
resonant converters," IEEE Trans. on Power Electronics, vol. 36, no. 5, 2021, pp. 5191-503.

[22] X. Wu and H. Shi, "High Efficiency High Density 1 MHz 380–12 V DCX With Low FoM
Devices," in IEEE Transactions on Industrial Electronics, vol. 67, no. 2, Feb. 2020, pp. 1648-
1656.

[23] Vicor, BCM6123TD1E1368T0R

[24] M. K. Ranjram and D. J. Perreault, "A 380-12 V, 1-kW, 1-MHz Converter Using a
Miniaturized Split-Phase, Fractional-Turn Planar Transformer," in IEEE Transactions on
Power Electronics, vol. 37, no. 2, Feb. 2022, pp. 1666-1681.

[25] M. K. Ranjram, P. Acosta and D. J. Perreault, "Design Considerations for Planar Magnetic
Terminations," 2019 20th Workshop on Control and Modeling for Power Electronics
(COMPEL), 2019, pp. 1-8.

[26] N. Dai, A. W. Lofti, C. Skutt, W. Tabisz and F. C. Lee, "A comparative study of high-
frequency, low-profile planar transformer technologies," Proceedings of 1994 IEEE Applied
Power Electronics Conference and Exposition - ASPEC'94, vol. 1, 1994, pp. 226-232.

[27] G. Skutt, F. C. Lee, R. Ridley and D. Nicol, "Leakage inductance and termination effects in
a high-power planar magnetic structure," Proceedings of 1994 IEEE Applied Power
Electronics Conference and Exposition - ASPEC'94, vol. 1, 1994, pp. 295-301.

[28] Y. Yang, D. Huang, F. C. Lee, and Q. Li, “Transformer shielding technique for common
mode noise reduction in isolated converters,” in Proc. IEEE Energy Convers. Congr. Expo.,
2013, pp. 4149–4153.

[29] Y. Yang, D. Huang, F. C. Lee, and Q. Li, “Analysis and reduction of common mode EMI
noise for resonant converters,” in Proc. IEEE Appl. Power Electron. Conf. Expo., 2014, pp.
566–571.

[30] A. Portolan and I. W. Hofsajer, "The Analysis and Design of an Inter-Winding Shielding
Structure of a High Frequency Transformer," 2007 IEEE Power Engineering Society
Conference and Exposition in Africa - PowerAfrica, 2007, pp. 1-6, doi:
10.1109/PESAFR.2007.4498122.
90
[31] C. Fei, Y. Yang, Q. Li and F. C. Lee, “Shielding technique for planar matrix transformers to
suppress common-mode EMI noise and improve efficiency”, IEEE. Trans. Ind. Elec., Vol.
65, No. 2, Feb 2018.

[32] Z. Ouyang, O. C. Thomsen and M. A. E. Andersen, "The analysis and comparison of leakage
inductance in different winding arrangements for planar transformer," 2009 International
Conference on Power Electronics and Drive Systems (PEDS), 2009, pp. 1143-1148, doi:
10.1109/PEDS.2009.5385844.

[33] A. F. Hoke and C. R. Sullivan, "An improved two-dimensional numerical modeling method
for E-core transformers," APEC. Seventeenth Annual IEEE Applied Power Electronics
Conference and Exposition (Cat. No.02CH37335), vol. 1, 2002, pp. 151-157.

[34] P. L. Dowell, “Effects of eddy current in transformer windings,” in Proc. Inst. Elec. Eng.,
vol. 113, 1966, no. 8, p. 1387.

[35] P. Thakur, D. Chahar, S. Taneja, N. Bhalla, A. Thakur, “A review on MnZn ferrites:


Synthesis, characterization and applications”, Ceram Int., Vol. 46(10), 2020, pp. 15740-
15763.

[36] M. Mu, Q. Li, D. Gilham, F. C. Lee, and K. D. T. Ngo, “New core loss measurement method
for high frequency magnetic materials,” in Proc. Energy Convers. Congr. Expo., 2010, pp.
4384–4389.

[37] D. Hou, M. Mu, F. C. Lee and Q. Li, "New High-Frequency Core Loss Measurement Method
With Partial Cancellation Concept," in IEEE Transactions on Power Electronics, vol. 32, no.
4, April 2017, pp. 2987-2994.

[38] W. G. Hurley, T. Merkin and M. Duffy, "The Performance Factor for Magnetic Materials
Revisited: The Effect of Core Losses on the Selection of Core Size in Transformers," in
IEEE Power Electronics Magazine, vol. 5, no. 3, Sept. 2018, pp. 26-34.

[39] A. J. Hanson, J. A. Belk, S. Lim, C. R. Sullivan and D. J. Perreault, "Measurements and


Performance Factor Comparisons of Magnetic Materials at High Frequency," in IEEE
Transactions on Power Electronics, vol. 31, no. 11, Nov. 2016, pp. 7909-7925.

[40] M. Mu and F. C. Lee, "A new core loss model for rectangular AC voltages," in Proc. 2014
IEEE Energy Conversion Congress and Exposition (ECCE), 2014, pp. 5214-5220.