Color Coding
Color Coding
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
TABLE OF CONTENTS
1. SCOPE
2. PURPOSE
3. REFERENCES
4. DEFINITIONS
5. UNITS AND CONVERSIONS
6. RESPONSIBILITIES
7. COLOR CODING
8. WEATHER CONDITION
9. METHODE & REQUIERMENTS
10. SAFTETY
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
1. PURPOSE
The purpose of this document is to outline the COLOR COADING & STENCLINIG, highlight quality control
procedures that will be applied to the Jafurah Upstream Pipeline & Well Tie-In Project. Color Coating and
Stenciling shall be executed in compliance with all related Saudi Aramco Engineering Standards (SAES),
Procedures, and IFC drawings.
2. Scope of Work
The scope of this document describes the COLOR COADING & STENCLINIG requirements for
the following Facilitates that will be carried out at worksites Installation.
Pipe Line & Piping
Structure
Skids
Equipment’s etc.
3. REFERENCES
4. DEFINITIONS
1. RESPONSIBILITIES
Construction Department Perform the work as per the requirements of Contract
Documents, IFC Drawings, Saudi Aramco Standards, SATIP, SAIC
and Project Quality Plan.
Paint Materials used at construction sites must be covered with appropriate canvas, tarpaulins,
or equivalent for a temporary storage period not to exceed 14 days and/or as recommended by
paint manufacturer.
Temperature sensitive polymerization paint materials must be stored in air conditioned storage
area to maintain the temperature as recommended in the Manufacturer’s Data Sheet.
8. WEATHER CONDITION
Painting shall not be applied when wind is strong enough to blow sand, salt spray or other foreign matter
onto the surface being painted.
Painting shall not be applied if the substrate temperature is less than 10 ͦC or limit given in the Saudi
Aramco data sheet
Relative humidity should be less than 90%
Surface temperature is less than 3 ͦC above the dew point.
Fire water system sectionalizing block valves shall be identified by their fire water system identification number.
9.3.Potable Water
Safety blue shall be used as the color indicator for potable water (sweet water and domestic raw water).
Specific requirements: Above-ground potable water piping in plant areas shall be painted blue.
Labeling and Letter Size on the Base of Pipe Diameter: (ANSI/ASME A13.1-
2007) Table No.1
Pipe Diameter Minimum Length of Label Field color Minimum Height of Letters
(Inch) / (mm) (Inch) / (mm) (Inch) / (mm)
Demineralize Water
Sky Blue 5015 1-Traffic White 9016
Utility Water
Sky Blue 5015 1-Jet Black 9005
Drinking Water
Sky Blue 5015 1-Aluminium 9006
Condensate Water
Sky Blue 5015 1-Pebble Grey 7032
Sky Blue 5015 1-Traffic Red 3020
Seal Flash Water
Sky Blue 5015 1-Opal Green 6026
Cooling water
Sky Blue 5015 1-Blue Lilac 4005
Blowdown Water
Sky Blue 5015 1-Light Ivory 1015
Boiler Feed
Water
Opal Green 6026 1-Jet Black 9005
Instrument Air
Opal Green 6026 1-Pebble Grey 7032
Plant Air
Traffic White 9016 1-Traffic Red 3020
HP Steam
Traffic White 9016 1-Traffic Orange 2009
MP Steam
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
Table B1 – Examples of word message letter heights and minimum safe viewing distances
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
YELLOW/BLACK 1018/9005
STAIRWAYS, TOE PLATES, LADDER UNDER 1M
STRIPES
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
ALUMINIUM 9006
PLANT PIPING, INCLUDING PACKAGE EQUIPMENT
ALUMINIUM 9006
VESSELS, TANKS, DRUMS, AIR COOLERS
ALUMINIUM 9006
DEAERATOR AND AUXILIARY
ALUMINIUM 9006
BOILERS STACKS AND SILEANCERS
ALUMINIUM 9006
CONDENSATE TRIM COOLER
ALUMINIUM 9006
BOILER BELOWDOWN COOLER
ALUMINIUM 9006
EXCESS LP CONDENSER
ALUMINIUM 9006
MAIN AIR COOLER CONDENSER
ALUMINIUM 9006
HP TO MP LETDOWN DE-SUPER HEATER
ALUMINIUM 9006
MP TO LP LETDOWN DE-SUPER HEATER
YELLOW 1021
LIFTING LUGS
TRAFFIC GREY 7042
HEAT RECOVERY STEAM GENERATOR/AUXILIRY BOILER CASING AND
DUCTING
ALUMINIUM 9006
CONTROL VALVES AND ACTUATORS
BLACK 9005
VALVES HAND WHEEL (FIRE WATER SYSTEM IS EXCLUDED)
YELLOW 1021
MOV ACLUATOR
GREEN(BONNET) 6016
PRESSURE RELIEF VALVES (BELLOWS TYPE)
ORANGE 2000
(BLOCK)
GREEN 6016
BONNET OF BELLOWS TYPE PRESSURE RELIEF VALVES
ORANGE 2000
MAINTENANCE BLOCKS VALVES FOR PRESSURE VALVES
ORANGE 2000
CAR-SEALED VALVES
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
ORANGE 2000
LOW-TEMPRATURE VALVES (-10 C TO -45 C)
GREEN 6005
STEAM TRAPS
YELLOW 1021
LIFTING EQUIPMENT DEVICES SUCH AS DAVITS, MONORAILS, & LIFTING
BEAMS (WHETHER PERMANENT OR USED ONLY FOR CONSTRUCTION).
MAXIMUM WEIGHT SHOULD BE LABLED.
RED 3000
EMERGENCY FIRE PROTECTION EQUIPMENTS BACKGROUND AND
100MM BORDER (EXTINGUSHERS, FIRE BLANCKETS, ETC.)
GREEN 6016
EMERGANCY SAFETY EQUIPMENT BACKGROUND AND 100MM BORDER
(FIRST AID, BREATHING APPRATUS, ETC)
GREEN AND WHITE 6016/9016
FIXED SAFETY EQUIPMENTS BACKGROUND (APPR 2M × 1M)
GREEN 6016
LOCATION OF SAFETY INSTRUCTION SHALL BE MARKED BY A SAFETY
GREEN BORDER OR BACKGROUND.
YELLOW 1021
EMERGENCY EXIT GATES THROUGH FENCE
YELLOW 1021
OWS CATCH BASINS BORDER OF 200MM
SNAMPROGETTI ENGINEERING & CONTRACTING CO.
LTD.
JAFURAH UPSTREAM PIPELINES AND WELLS TIE-IN PROJECT
REPAIR PROCEDURE FOR GALVANIZED
STEEL
BI-11-19034-
CONTRACTOR NO.6600050464 (IK) JOB No. 4003
240812 BI-11-20034-
4002
GREEN 6021
ELECTRICAL MOTORS
GREEN 6021
GENERATORS
LIGHT GREY 7035
VFD
LIGHT GREY 7035
TRANSFORMERS
TRAFFIC GREY 7042
ELECTRICAL CABINETS AND MISCELLANEOUS ELECTRICAL EQUIPMENT
(INSIDE & OUT SIDE)
LIGHT GREY 7035
INSTRUMENTS CABINETS IN PCS (INSIDE & OUT SIDE)
TRAFFIC GREY 7042
PLINTH FOR INSTRUMENTS CABINETS
GREY ANSI-61
METAL-ENCLOSED LOW-VOLTAGE SWITCH GEAR ASSEMBLIESS
GREY ANSI-61
INDOOR CONTROL GEAR- LOW VOLTAGE
GREY ANSI-61
INDOOR METAL-CLAD SWITCH GEA: 1 TO 38 KV
LIGHT GREY 7035
HIGH VOLTAGE SWITCHGEAR-OUT DOOR
TRAFFIC GREY 7042
TAP CHANGER CONTROL PANEL
LIGHT GREY 7035
DC SYSTEM
LIGHT GREY 7035
AC UPS
LIGHT GREY 7035
HVAC CONTROL PANEL
LIGHT GREY 7035
INTERPOSING RELAY PANEL
9.8. Identification color label size is mentioned in Table No. 4 as Per Pipe Diameter.
Diameter of Pipe A B C D E
(mm) (mm) (mm) (mm) (mm) (mm)
350 50 25 30 20
Up to 100
680 200 40 50 35
From 100 to 250
820 250 50 60 45
Greater than 250
Table no.4