Precision Cooling System
Foundation of Digital Future
The professional cooling solutions for you to build highly Reliable,
Efficient and Green Data Center.
Customize with Expert
SmoothAirTM – Row Mount DX
Air cooled, row mount, split type, ideal for
micro data center, integrated modular data
center solutions.
5.6kW –90.1kW
300 /600 /900mm Width
Dynamically modulated cooling
5 2 capacity with inverter compressor
1 maintains temperature within envelop
and prevent compressor from cycling
during low heat load period.
7
Air flow modulates with EC fans to
match IT equipment requirements.
3 2 Each fan module is easy to change
with quick couple connections.
Precision cooling controller monitors
3
and protects unit constantly. Easy to
be integrated into BMS to display,
4
control and manage the system.
R410A green refrigerant is highly
4 efficient and no ODP.
6
1 Copper piping adopts quick
5 connections and supports bottom and
top connections.
8 Easy to change G4 air filter and sealed
6 doors help to build a clean and quiet
MDC.
7 Slide drawer style electric box makes
service easier.
5
Optional with condensate pump,
8 leaking kit and long piping kit for
diverse applications.
SmoothAirTM – Row Mount DX
Technical Data
Indoor Unit S-005RA S-007RA S-012RA S-017RA S-020RA S-025RA S-030RA S-040RA S-050RA S-065RA S-075RA S-090RA
Total Cooling-kW 5.6 7.6 12.8 17.6 21.2 25.1 31.1 40.9 51.2 65.7 76.8 90.1
SHR-% 100 100 100 100 100 100 100 100 100 100 100 100
Air Volume-m3/h 2000 2250 2400 4500 4920 5000 5800 8000 10000 12000 13500 16000
Mount Type Row Row Row Row Row Row Row Row Row Row Row Row
Cooling Type DX DX DX DX DX DX DX DX DX DX DX DX
Height-mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
Depth-mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
Width-mm 300 300 300 300 300 300 300 600 600 600 900 900
Weight-kg 210 213 233 253 258 260 320 360 420 460 540 620
Reheat-kW 3.0 3.0 3.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0
Hum.(optional)-kg/h 1.5 1.5 1.5 1.5 1.5 1.5 3 3 3 3 3 3
208-240V 208-240V 208-240V 380-415V 380-415V 380-415V 380-415V 380-415V 380-415V 380-415V 380-415V 380-415V
Power Input1) /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz
/1Ph-2Ph /1Ph-2Ph /1Ph-2Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph
FLA-A1)with heating 28.2 37.3 48.7 27.0 26.7 27.9 34.6 37.7 48.1 60.6 70.8 84.6
FLA-A1)with hum. 33.3 42.4 53.8 32.1 31.8 33.0 39.7 47.9 58.3 70.8 81.0 94.8
380-415V 200-230V 200-230V 200-230V 200-230V 200-230V
Power Input2) - - /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz - - - -
/3Ph /3Ph /3Ph /3Ph /3Ph /3Ph
FLA-A2)with heating - - 20.9 49.4 48.8 51.1 63.2 68.9 - - - -
2)with hum.
FLA-A - - 22.0 52.5 52.0 54.2 66.4 75.1 - - - -
460V 460V 460V 460V 460V 460V 460V 460V 460V
Power Input3) - - - /60Hz /60Hz /60Hz /60Hz /60Hz /60Hz /60Hz /60Hz /60Hz
/3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph /3Ph
FLA-A3)with heating - - - 22.3 22.1 23.1 28.6 31.1 39.7 50.1 58.5 69.9
3)with hum.
FLA-A - - - 26.5 26.3 27.3 32.8 39.6 48.2 58.6 66.9 78.4
Standard Outdoor
Unit Model KSF08AN KSF12AN KSF18AN KSF24AN KSF32AN KSF38AN KSF42AN KSF52AN KSF62AN KSF85AN KSF52AN KSF62AN
Unit Qty 1 1 1 1 1 1 1 1 1 1 2 2
Notes:
1. Air flow is based upon standard fan speed setting. Fan modulates per real loads.
2. Cooling Capacity based on 37℃/24%RH return air and 45℃ condensing temperature.
3. FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit.
4. SNMP monitoring port, dual power input, and leaking detection are optional.
5. Standard unit works -15℃ above outdoor temperature, select low temperature kit to run for -35C outdoor ambient temperature.