AMUR GAS CHEMICAL COMPLEX (AGCC) – PE/PP/LAO UNITS

ICSS Architecture Drawing

Customer Name : Tecnimont

End User Name : Amur Gas Chemical Complex LLC

This proposal contains technical and business information that is confidential and
Proposal No : QLK-2009-5162660 Rev. 2 Rev. Date 22-FEB-2021
proprietary to Schneider Electric. It is provided to Customer solely for internal review and
evaluation. The information contained herein may not be shown or disclosed in any form
to third parties without the express consent of Schneider Electric.
Scale NTS Sheet No 1 of 9
Abbreviations Notes Table of Contents
Note 1. Description Page No.
APCS Advanced Process Control System Cover Page Sheet 1
AMS Alarm Management System
Note 2. Table of Contents, Abbreviations & Legend Sheet 2
ASR Automation Server Room
ICSS Integrated Control and Safety System Block Diagram Sheet 3
CCR Central Control Room Overall System Architecture Sheet 4
Note 3.
DCS Distributed Control System
Overall System Architecture Continued Sheet 5
EWS Engineering Workstation
FDS Fire Detection System PCN Network Sheet 6
FDCP Fire Detector Control Panel SIS/GDS Network Sheet 7
FOPP Fiber Optic Patch Panel PIN Network Sheet 8
GDS Gas Detection System Legends
GPS Global Positioning System ROOT SWITCHES Remote Control Room Sheet 9
Managed layer 3 switch to connect different plant areas
HART Highway Addressable Remote Transducer
HMI Human Machine Interface EDGE SWITCHES
Managed layer 2 switches used to connect equipment to the PCN
IAMS Instrument Asset Management System
ICSS Integrated Control and Safety System DISTRIBUTION SWITCHES

L2SW Layer 2 Switch Managed layer 3 switch to interface edge switches

L3SW Layer 3 Switch


LAN Local Area Network Plant Information Network (PIN)
MFCU Mixed Feed Cracker Unit
Process Control Network - Redundant (PCN)
NTP Network Time Protocol
OTS Operator Training Simulator Safety Network - Redundant (SIS/GDS)
OWS Operator Workstation Package Unit Interface
PCN Process Control Network
PIN Plant Information Network FO Network

PDP Power Distribution Panel


Interconected System
PAGA Interface to Public Address and General Alarm
System
RIE Remote Instrument Building Field Device Controller (FDC280), (Redundant)

SIS Safety Instrumented System


SJB Smart Junction Box
SOE Sequence of Event Triconex Communication Module (TCM) , (Redundant)
SS Substation
TCP/IP Transmission Control Protocol/Internet protocol
TC Thin Client
WS Workstation

Rev Status Description Date BY CHK’D APPV’D


0 IFD Issued For Review 21-OCT-2020 MH DC FC
1 REV Revised As Per Technical Alignment Meeting 19-NOV-2020 MH/DC DC FC
2 REV Revised As Per ISS Technical Alignment Meeting 22-FEB-2021 MH/DC DC FC/RV

Scale :
Notes Title Table of Content NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 2 of 9
PE/PP/LAO UNITS
REMOTE CONTROL
BUILDING 8200 CCB

HMI

ENGINEERING &
HMI Refer to page 8 for
further details OTS APC

DCS

PIN NETWORK

PCN NETWORK

SIS/GDS NETWORK

3820‐RIE‐01 4820‐RIE‐01 9820‐RIE‐01


PEU‐1 & LAO PPU
PEU‐2

HMI HMI HMI

DCS SIS DCS SIS DCS SIS

GDS PDS GDS GDS

PIN NETWORK
PCN NETWORK
SIS/GDS NETWORK

Rev 2
NOTE ‐1

5601‐PB‐01
LOGISTIC RIE
RIE EXTRUDER

HMI

DCS -
REMOTE
IO
DCS -IO SIS – IO

GDS –
IO

Scale :
Notes (1) Only interface with main PCN network is in SE scope.
Title BLOCK DIAGRAM
NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 3 of 9
CENTRAL CONTROL ROOM (CCR) PRINTER ROOM
PIN NETWORK
TC TC TC TC
Large Screen 24" 24" 24" 24" 24" 24" Large Screen TC TC 24" 24" 24" 24" 24" 24" Large Screen TC TC 24" 24" 24" 24" 24" 24" Large Screen
TC TC

24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24"
24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24"
Printer Printer Printer Printer
KVM KVM KVM KVM KVM KVM KVM KVM KVM A3 Color A3 Color A3 B/W A3 B/W
24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24"

OWS 1 OWS 2 OWS 3 OWS 4 OWS 5 OWS 6 OWS 1 OWS 2 OWS 3 OWS 4 OWS 5 OWS 6 OWS 1 OWS 2 OWS 3 OWS 4 OWS 5 OWS 6 OWS
SDC PEU‐1 Train 1/ SDC PEU‐1 Train 2/ SDC PEU‐1 Train 3/
PEU‐1 Train 1/ PEU‐1 Train 1/ PEU‐1 Train 1/ PEU‐1 Train 1/ PEU‐1 Train 1/ PEU‐1 Train 2/ PEU‐1 Train 2/ PEU‐1 Train 2/ PEU‐1 Train 2/ PEU‐1 Train 2/ PEU‐1 Train 3/ PEU‐1 Train 3/ PEU‐1 Train 3/ PEU‐1 Train 3/ PEU‐1 Train 3/ Supervisor (By others) (By others) (By others) (By others)
PEU‐1 Train 1 PCO PEU‐1 Train 2 PCO PEU‐1 Train 3 PCO
PCO PCO PCO PCO PCO PCO PCO PCO PCO PCO PCO PCO PCO PCOPEU‐1 PCO PEU‐1 Train 1
CENTRAL CONTROLO BUILDING (8200‐CCB)

NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐2 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐2 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐2 NOTE ‐1 NOTE ‐ 5
From/To From/To From/To
SIS/GDS/DCS
PCN NETWORK Cab in ASR
SIS/GDS/DCS
Cab in ASR
SIS/GDS/DCS
Cab in ASR

ENGINEERING ROOM (AEO)


PIN NETWORK

SIS/GDS NETWORK TC TC TC TC TC TC TC TC TC

24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" Rev 1

DCS DCS DCS SIS/GDS SIS/ SIS/GDS IAMS IAMS IAMS AMADAS
PEU 1 & LAO PEU 2 PPU PEU 1 & LAO GDS PPU PEU 1 & LAO PEU 2 PPU SERVER NMS
EWS EWS EWS EWS EWS EWS EWS EWS EWS

NOTE ‐2
PCN NETWORK NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2

FROM SHUTDONW FROM SHUTDONW NOTE ‐ 5 OPC INTERFACE


PANELS AND PANELS AND BUSINESS NETWORK
PIN NETWORK MAINTENANCE MAINTENANCE Rev 2 TO OTHER
OVERRIDE SWITCH
PANELS IN CCR
OVERRIDE SWITCH
PANELS IN CCR GPS ANTENNA
TO ROC SYSTEMS AUTOMATION

Anti Virus Server


‐ ESCADA,

Portal/web Server

Terminal Server‐
Domain Server‐
OPC Server 1 –
SERVER ROOM

Server 2 –
AMADAS , UI&O

Secondary
3rd Party

3rd Party
Interface

Interface

Admin
DCS (by other),
DCS SIS/GDS SERVER SMIS, MESS, NETWORK (ASR)

PEU 1‐Tr 1 OWS

PEU 1‐Tr 1 OWS

PEU 1‐Tr 2 OWS

PEU 1‐Tr 2 OWS

PEU 1‐Tr 3 OWS

PEU 1‐Tr 3 OWS

LAO‐SOWS with
Crypto

OPC
LAO OWS with
SYSTEM SYSTEM CABINET PSS, PMS,

SIS/GDS EWS
with 65" LSD
PEU 1‐SOWS
with 65" LSD
with 65" LSD

with 65" LSD

IAMS Server
PEU1 & LAO

PEU1 & LAO

PEU1 & LAO


Gateway CABINET

LAO OWS

DCS EWS
MARSHAL

x 2 Nos.

x 2 Nos.

x 2 Nos.
Other EPC

65" LSD
65" LSD
MARSHAL Cluster
L.CABINET L.CABINET
V91 # 9 To Admin
Building –
TIME SYNC Tape Drive
AMADAS SERVER
FDC280 (SNTP) SERVER FW Cluster Domain Server Prim.
To Admin
Building –
PACKAGE DMZ SW Tape Drive
UNITS V91 # 1 V91 # 2 V91 # 3 NOTE ‐2 DMZ NETWORK NOTE ‐ 7
NOTE ‐ 2 NOTE ‐ 1 NOTE ‐ 1 NOTE ‐ 1 NOTE ‐ 7
ICSS BACKUP SERVER FOC NOTE ‐ 2
NOTE ‐ 3
PACKAGE UNITS
FDC280 FOC
PCN NETWORK NOTE ‐ 3 BACKRUP SERVER

SIS/GDS NETWORK SIS/GDS NETWORK

PIN NETWORK PIN NETWORK


3820‐RIE‐01 4820‐RIE‐01
ENGINEERING CONSOLES ENGINEERING CONSOLES

24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24"
PACKAGE/PLC PACKAGE/PLC
UNITS UNITS
EWS/OWS EWS/OWS
DCS SIS & GDS IAMS DCS SIS & GDS IAMS
NOTE ‐ 5 EWS EWS EWS EWS EWS EWS
COLOR COLOR
PRINTER NOTE ‐ 5 PRINTER
(By others) NOTE ‐4 NOTE ‐4 NOTE ‐3 (By others) NOTE ‐4 NOTE ‐4 NOTE ‐3
PCN NETWORK PCN NETWORK

SIS/GDS NETWORK FDC280 FDC280


SIS/GDS NETWORK
FDC280 FDC280

PROCESS PROCESS
SUBSTATION SUBSTATION
DCS SIS GDS PDP PDP DCS SIS GDS NETWORK FOPP PDP PDP
NETWORK FOPP
SYSTEM SYSTEM SYSTEM CABINET CABINET SYSTEM SYSTEM SYSTEM CABINET CABINET CABINET CABINET
IRP CABINET CABINET FDC280 FDC280 IRP
FDC280 FDC280 FDC280 MARSHAL MARSHAL FDC280 MARSHAL MARSHAL MARSHAL (UPS) (NON‐
MARSHAL CABINETS (UPS) (NON‐ CABINETS
L.CABINET L.CABINET L.CABINET UPS) L.CABINET L.CABINET L.CABINET UPS)

Other MCC Package PLC Other


MCC Package PLC Packages Packages

ELECTRICAL ELECTRICAL
MCC MCC

FIELD FIELD
FIELD FIELD INSTRUMENT FIELD INSTRUMENT FIELD
FIELD INSTRUMENT FIELD INSTRUMENT GAS SENSOR GAS SENSOR

Scale :
Notes (1) OWS Virtual Machines are accessible through thin clients in CCR and installed in the server cabinets.
Title
DCS EWS, SIS/GDS EWS, Historian Virtual Machines are accessible through thin clients in AEO and installed in server cabinets.
(2) All Physical Workstations and Servers are accessible through KVM Extender and installed in server cabinets.
OVERALL SYSTEM ARCHITECTURE NTS
(3) IAMS in RIE will be temporary moved from CCB for commissioning.
(4) Workstations in RIE will be installed in Operator consoles.
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units
(5) Printers not in SE scope of supply..
(6) Separate cabinets are considered for servers and workstations.
(7) Connectivity between ASR and Admin Building in others scope QLK-2009-5162660 2 4 of 9
CENTRAL CONTROL ROOM (CCR)
PIN NETWORK
TC TC TC TC TC TC
Large Screen TC TC Large Screen Large Screen Large Screen Large Screen Large Screen ADMINISTRATION BUILDING
24" 24" 24" 24" TC TC 24" 24" 24" 24" 24" 24" TC 24" 24" 24" 24"
Rev 2
24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" 24" TAPE DRIVE

24" 24" 24" 24" 24" 24" KVM KVM 24" 24" 24" 24" 24" 24" 24" 24" KVM KVM KVM 24" 24" 24" 24" 24" 24" KVM KVM 24" 24"
FOC

OWS
OWS Frrom Back-up
OWS 1 OWS 2 SDC OWS 3 OWS 4 OWS 5 OWS 1 OWS 2 SDC OWS 3 OWS 4 OWS 5 OWS 6 OWS OWS 1 OWS 2 SDC OWS 3 OWS 4 Supervisor LAO
Supervisor server in ASR-
PEU‐2/PCO PEU‐2/PCO PEU‐2 PEU‐2/PCO PEU‐2/PCO PEU‐2/PCO PPU/PCO PPU/PCO PPU PPU/PCO PPU/PCO PPU/PCO PPU/PCO Supervisor PPU LAO/PCO LAO/PCO LAO LAO/PCO LAO/PCO & Plant
PEU‐2 LOC
monitoring

NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐2 NOTE ‐1 NOTE ‐1 NOTE ‐1 NOTE ‐2 NOTE ‐2 NOTE ‐1
From/To From/To
CENTRAL CONTROLO BUILDING (CCB)

From/To
PCN NETWORK SIS/GDS/DCS
Cab in ASR SIS/GDS/DCS
Cab in ASR
SIS/GDS/DCS
Cab in ASR

ENGINEERING ROOM (AEO) Remote Control Room (ROC)

PEU 1‐Tr 2 OWS

PEU 1‐Tr 2 OWS

PEU 2 OWS with


PEU 2‐ OWS x 4
PEU 1‐Tr 3 OWS
PEU 1‐Tr 1 OWS

PEU 1‐Tr 3 OWS


PEU 1‐Tr 1 OWS

PEU 1/LAO DCS


PEU 1/LAO SIS/
with 65" LSD

PPU DCS EWS


with 65" LSD
with 65" LSD

Supervisory

Supervisory
PIN NETWORK

PEU 2 DCS

PEU 1 DCS
x 5 Nos.

GDS EWS
x 5 Nos.
x 5 Nos.

65" LSD
Rev 2

Nos.

EWS
TO AGCC LOC

Domain Server
‐ Secondary
Anti Virus
Server
SERVER
Crypto
V91 # 1 V91 # 2 V91 # 3 V91 # 4 V91 # 5
CABINETS Gateway
(separate Cluster
for HW
servers V91 # 7
and for
FW Cluster
PIN NETWORK
ISS) Domain Server Prim.
NOTE ‐2

PEU 2 SIS/GDS

PPU SIS/GDS
Supervisory
PEU 2 DCS

PPU DCS
DMZ NETWORK

EWS

EWS

EWS
DMZ SW
ICSS BACKUP SERVER
PCN NETWORK NOTE ‐ 3
PIN NETWORK V91 # 6

PIN NETWORK AUTOMATION


SERVER ROOM
NOTE ‐ 6
SERVER / (ASR)

PPU IAMS Server

PEU1 APC Server


PPU SOWS with

Historian Server
PEU2 APC Server
PEU 2 OWS with

Terminal Server
Primary Domain
WORKSTATION

ICSS SOE Server


LAO APC Server

PPU DCS EWS


PEU2 DCS EWS

PPU OWS with


PEU2 OWS x 2

PPU SIS/GDS

OPC Server for


PEU2 SIS/GDS

APC Interface
PEU 2‐SOWS
with 65" LSD

PPU OWS x 2
Domain Ctlr

PEU2 IAMS
Secondary
CABINET

65" LSD
65" LSD

65" LSD
Server

EWS
Nos.

EWS

Nos.
Ctlr

V91 # 4 V91 # 5 V91 # 6 V91 # 7 V91 # 8


NOTE ‐ 1 NOTE ‐ 1 NOTE ‐ 1 NOTE ‐ 1 NOTE ‐ 1

PCN NETWORK

SIS/GDS NETWORK SIS/GDS NETWORK

PIN NETWORK 9820‐RIE‐01 PIN NETWORK LOGISTIC‐RIE


5601‐PB‐01
NOTE ‐ 7 NOTE ‐ 6
ENGINEERING CONSOLES ENGINEERING CONSOLES

PACKAGE/
NOTE ‐ 8 PLC UNITS 24" 24" 24" 24" 24" 24" NOTE ‐ 8 24" 24" 24" 24" 24" 24"
EWS/OWS PACKAGE/PLC
UNITS
EWS/OWS
COLOR
OWS OWS OWS DCS SIS & GDS IAMS OWS OWS OWS PRINTER DCS SIS & GDS IAMS
PEU 1 PEU 1 PEU 1
EWS EWS EWS PEU2 PPU PPU NOTE ‐ 5 EWS EWS EWS
EXTUDER 1 EXTUDER 2 EXTUDER 3 EXTUDER EXTUDER 1 EXTUDER 2 (By others) COLOR
PRINTER
(By others)
NOTE ‐4 NOTE ‐4 NOTE ‐3 NOTE ‐4 NOTE ‐4 NOTE ‐3
PCN NETWORK PCN NETWORK

SIS/GDS NETWORK TECHNICAL ROOM NEAR


EXTRUDER SIS/GDS NETWORK
FDC280 FDC280
FDC280 FDC280
NOTE ‐5 & 8 LOCAL
PROCESS HMI PROCESS
SUBSTATION SUBSTATION
DCS SIS GDS PDP PDP DCS SIS GDS NETWORK FOPP PDP PDP DCS
NETWORK FOPP
SYSTEM SYSTEM SYSTEM CABINET CABINET SYSTEM SYSTEM SYSTEM CABINET CABINET CABINET CABINET SYSTEM
FDC280 FDC280 FDC280 IRP CABINET CABINET FDC280 FDC280 FDC280 IRP
MARSHAL MARSHAL MARSHAL (UPS) (NON‐ MARSHAL MARSHAL MARSHAL (UPS) (NON‐ MARSHAL
CABINETS CABINETS
L.CABINET L.CABINET L.CABINET UPS) L.CABINET L.CABINET L.CABINET UPS) L.CABINET

MCC Package PLC Other MCC Package PLC Other


Packages Packages

ELECTRICAL ELECTRICAL
MCC MCC

FIELD FIELD FIELD


FIELD FIELD FIELD INSTRUMENT
FIELD INSTRUMENT FIELD INSTRUMENT FIELD INSTRUMENT FIELD INSTRUMENT GAS SENSOR
GAS SENSOR
(1) OWS Virtual Machines are accessible through thin clients in CCR and installed in the server cabinets.
Scale :
Notes Title
DCS EWS, SIS/GDS EWS, Historian Virtual Machines are accessible through thin clients in AEO and installed in server cabinets.
(2) All Physical Workstations and Servers are accessible through KVM Extender and installed in server cabinets.
(3) IAMS in RIE will be temporary moved from CCB for commissioning.
OVERALL SYSTEM ARCHITECTURE Conitnued NTS
(4) Workstations in RIE will be installed in Operator consoles.
(5) Not in SE scope of supply Proposal No Rev Sheet No.
(6) Separate cabinets are considered for servers and workstations.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660
(7) Direct connection between 5601 and CCB is not foreseen. Similar is the case for Logistic RIE.
(8) One Local HMI per Extruder and supplied bu others. SE has made provision for connectivity of local HMI to PIN switches. Interface cables are to local HMI also not SE scope. 2 5 of 9
8820‐CCB

CCB
EDGE
SWITCHES

ROOT
SWITCHES

3820‐RIE‐01 4820‐RIE‐01 9820‐RIE‐01


EDGE EDGE EDGE
SWITCHES SWITCHES SWITCHES

5601‐PB‐01 LOGISTIC‐RIE
EDGE
SWITCHES DCS – REMOTE IO

Scale :
Notes (1) PCN is redundant network. Title PCN NETWORK NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 6 of 9
8820‐CCB

CCB
EDGE
SWITCHES

ROOT
SWITCHES

3820‐RIE‐01 4820‐RIE‐01 9820‐RIE‐01


EDGE EDGE EDGE
SWITCHES SWITCHES SWITCHES

5601‐PB‐01
EDGE
SWITCHES

Scale :
Notes Title
(1) P2P Network is redundant network. SIS / GDS NETWORK NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 7 of 9
8820‐CCB

EDGE
SWITCHES

ROOT
SWITCHES

CENTRAL
3820‐RIE‐01 4820‐RIE‐01 9820‐RIE‐01 LABORATORY
E&I WORKSHOP
EDGE EDGE EDGE EDGE EDGE
SWITCHES SWITCHES SWITCHES SWITCHES SWITCHES

5601‐PB‐01
EDGE
SWITCHES

Scale :
Notes Title
(1) PIN Network is Simplex. PIN NETWORK NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 8 of 9
Local Control Room
6 000 km

DCS
EWS DCS OPTIONAL
Application
(Galaxy) OWS Servers
Remote Control Room(ROC)
Provider # 1 Rev 2

ICSS Red ICSS Red


PIN Network Firewall Provider # 2 Firewall
PIN Network
(WW MX Protocol) (WW MX Protocol)
Note 1 WAN WAN
PCN Network

PEU 1‐Tr 2 OWS

PEU 1‐Tr 2 OWS

PEU 2 OWS with


PEU 2‐ OWS x 4
PEU 1‐Tr 3 OWS
PEU 1‐Tr 1 OWS

PEU 1‐Tr 3 OWS


PEU 1‐Tr 1 OWS

with 65" LSD

with 65" LSD


with 65" LSD

Supervisory
PEU 2 DCS
x 5 Nos.

x 5 Nos.
x 5 Nos.

65" LSD
Nos.
DCS
ESD V91 # 1 V91 # 2 V91 # 3 V91 # 4

PPU OWS with


PEU 2 DCS EWS
PEU 1/LAO DCS

PEU 1/LAO SIS/

PPU OWS x 5
PEU 2 SIS/GDS
PPU DCS EWS

PPU SIS/GDS
Supervisory
Supervisory
PEU 1 DCS

GDS EWS

PPU DCS

65" LSD
Nos.
EWS

EWS
EWS
PCN Network
V91 # 5 V91 # 6 V91 # 7

Scale :
Notes (1) OWS/EWS Virtual Machines are accessible through thin clients in ROC and installed in the server cabinets. Title REMOTE CONTROL ROOM NTS
Proposal No Rev Sheet No.
Project Name ICSS‐AGCC Project PE/PP/LAO Units QLK-2009-5162660 2 9 of 9