LMS Plus FDC– V 72

LMS Plus
Version 7.x
OPERATOR MANUAL

Fantuzzi FDC

1
LMS Plus FDC– V 72

1
LMS Plus
description

Introduction
This manual describes LMS Plustm System installed on the FDC machines.
LMS Plus is based on a multiple CAN bus network, with the integration of
FRED or third part electronic units (nodes), each one dedicated to a specific
function in the machine.
A single display, designed with automotive standards, allows a complete
information management and machine troubleshooting, even if it is not basic for
machine working (machine works even without display).

Main functions:

• Test of all signals connected to the system.


• Advanced driver control management via badge
• Complete boom control, statically and dynamically
• Complete machine speed control, integration with transmission and engine
• Full compatibility with any kind of engine and transmissions (traditional or
new generation)
• Complete spreader control and monitor
• Malfunction black box: all sensors malfunctions, overloads and bypass use
are stored in a permanent memory
• Operative black box: all information of containers moved is stored into a
permanent memory
• container handling information
• Compatibility with TruckTracktm system

2
LMS Plus FDC– V 72

System layout
This is the main machine layout, with all CAN bus nodes present in the
network:

CABIN

LMS
edgevision Badge
Operators

joystick CAN

hydraulic joystick
Speed
selector

Accelerator
Pedal
Main CAN

TRUCK
CAN 2
(J1939)
Powertronic

TRANSM.
MultiCAN
Sensors

3
LMS Plus FDC– V 72

LMS Plus is compatible with Truck


Track system.

LMS Plus PC server


WEB

COM1

world wide
web

LMS Plus sends both black box: operative and alarms. PC server
receives this data and it put on worl wide web. Using a PC connected
on internet it is possible to see how the LMS works (see TruckTrack
manual for more details).

4
LMS Plus FDC– V 72

2
Using the machine

Access Level
1. operators badge (optional)
At machine startup, the system requires for a operator code.
The code can be inserted using the Badge system: each operator must be
provided with its own Badge where the operator code is stored.

The operator code will be used to store any kind of event.

Without code, machine and boom can’t be moved:


transmission is set to neutral and boom is locked

If any problem occurs on Badge reading, LMS Plus will allow a manual code
insertion (using external keyboard); in this case, only maintenance code will be
accepted.

Any login of maintenance code will be stored in the black box.

5
LMS Plus FDC– V 72

Front panel description


The operator can only drive the machine and check what it is happening on the
display.
(*)

1 2 4

3 6
8

1. Transmission : desired and actual


2. Fuel level
3. Engine hour running
4. Coolant temperature
5. Gear oil temperature
6. Engine RPM
7. Machine Speed
8. Alarms and warnings

6
LMS Plus FDC– V 72

Front panel keys use

Information regarding the software installed and system type (exit


with F4)

ENGINE ALARM shutdown or CAN fault


ENGINE START: Engine is starting
ENGINE READY: Engine is running
DRIVER accelerator pedal; ENGINE power required to the engine

F3 screen shows the machine configuration: Transmission type,


Engine type, spreader type and the engine diagnostic mode.
Exit with F4

Odometer (Km counter); Battery voltage (voltage); and the number


of containers are also available

Increases LCD contrast

Decreases LCD contrast

Bypass entering codes page. It is like the BYPASS key in the


external keyboard

Enter button to insert the bypass code

7
LMS Plus FDC– V 72

Hydraulic Operator joystick


On standard machines, an hydraulic joystick is installed. Buttons are still
electrical and these are their functions:

1. Twistlocks unlocked
2. Twistlocks locked
3. Sideshift left
4. Sideshift right
5. Rotazione anti clockwise (*)
6. Rotazione clockwise (*)

(*) Only Double Box Spreader

8
LMS Plus FDC– V 72

3
LMS Plus features

Transmission control
LMS Plus controls transmission in automatic or manual mode (a key on the
panel selects the mode).
In case of manual mode, the driver will have to select the desired speed using
the speed selector.
In case of automatic mode, the operator has only to select the maximum speed
to reach and press the throttle. LMS Plus will insert the proper gear according to
machine speed, the engine RPM and to the parameters stored on the Engine
Plcore (adjustable by mean an external keyboard connected on the display).
If it is installed a new electronic type transmission (like Dana TE series, for
example), nothing will change from operator point of view.

Safeties transmission provided:


All safeties to prevent an incorrect transmission are the followings:
1. engine RPM higher than 1000 RPM (is adjustable)
2. during a changing of the vehicle direction, the machine speed higher
than 0,5 km/h (is adjustable)
3. parking brake: this to prevent excessive stress on transmission
4. the button located close to pedal brake with any gear engaged (declutch
function)
5. Speed sensor check (on drive shaft): If the sensor located on drive shaft
does not supply a correct signal, the transmission is set to neutral; to
reset the alarm, it is necessary to set the speed selector to neutral.
If that was a false warning (sometimes it may happen), the transmission
starts working normally again. In case the sensor was really fault or
disconnected, the transmission will keep always first speed.
Only switching to manual mode it will be then possible to go to any
speed, but, in this case, all safeties will be not active anymore.

9
LMS Plus FDC– V 72
When one or more of these safeties comes up then the transmission will be set
to neutral position.
All safeties are removable inserting a “BYPASS TRANSMISSION” or “BYPASS
TOTAL”.
The speed of the machine is related to the accelerator pedal position and in
according to the machine limit speed.

High performance provided:


All features to get better a transmission performance are the followings:
1. Pedal kick-down control: pressing throttle pedal at maximum, LMS Plus
moves forward of some percentage (normally 20-30%) shifting points.
This means that shift points will be activated at higher machine speed
and engine RPM..

2. Engine torque control (dethrottle): during shifting (to higher gears) the
engine RPM is decreased automatically, in order to avoid a gears
engagement with engine at high torque. Engine RPM will be restored as
set by pedal with a ramp as soon as the shifting is terminated.

3. Load control: LMS Plus uses the weight information to change shifting
points. In case of machine loaded (over 7 tons), LMS Plus uses a
different shift points table, built so that gears are engaged at higher
speed and engine RPM, in order to have a sufficient engine power to
travel and use the boom.

Mechanical Transmission Clark 36000


In this case the transmission gear valve are connected directly to the Truck
PLCore unit.

Electronic Transmission APC200


In this case the transmission proportional valve are connected directly to the
APC200 unit.

TE27 transmission have its own electronic control unit, called APC200 and this
one receives transmission instructions to set the properly gear from a LMS Plus
by mean a secondary CAN bus communication using (in some part) the
standard J1939. This means APC200 works only in manual mode.
On the main screen of the LMS Plus display, the transmission status and the
shift lever position are shown.

Fig1. APC200 electronic unit

10
LMS Plus FDC– V 72
Engine and speed control
LMS Plus controls completely the engine starting from the information of the
pedal position and machine conditions.
The communication protocol follows the standard SAE J1939, and this allows
the control of any kind of engine (equipped with ECU - electronic control unit).

These are functions available:


1. Speed control

Stability condition Maximum speed Notes


Normal 25 Km/h No warning conditions as
above

2. CAN communication control


The system performs a constant check of CAN communication status
with the engine electronic unit, otherwise engine is set to minimum,
independently from pedal position.

3. Engine on/off control


The engine is not started if speed selector is not neutral.
When the operator turn off the engine key, LMS Plus keep engine at
minimum RPM for at least some seconds, in order to avoid turbo charger
overheating.
Engine is shut off with following alarms:

Alarm Alarm threshold


Low fuel level < 5%
High transmission oil temperature > 120 °C
High cooling water temperature > 105 °C
Low engine oil pressure < 1 bar
Low cooling water level (option) Ground signal

Alarm thresholds parameters can be adjusted by technical assistance.


On some special versions, the number and type of events that shut
engine off may be different.

4. Turbo timer
After turn off the key, the engine will be shut down only after some seconds if
the operator has pressed the pedal a full throttle. This function are available
only for Volvo electronics.

11
LMS Plus FDC– V 72

Safeties boom provided


Mast lifting
All safeties to prevent an incorrect mast lifting are the followings:
1. overload due to the weight bigger than the max capacity or due to the one
or more weight sensor broken and is removable inserting a “BYPASS
OVERLOAD” (if the weight sensor is installed)
2. locked and unlocked sensors are both not active

Mast lowering only Single Box Spreader


All safeties to prevent an incorrect mast lifting are the followings:
1. seated sensor is not active

Spreader boom provided


Spreader lock and unlock Twist Single Box Spreader
The conditions that allows this function is:
1. to press lock / not unlock button
2. seated sensor active

Spreader lock and unlock Clamp Double Box


The conditions that allows this function is:
1. seated dx sensor active and seated sx sensor active
2. to press lock / not unlock button

WARNING, in case of container lifting and driving with clamps in


OPEN position, the following audible and visual alarm is activated:

31 – spreader not locked


Travelling speed is reduced if clamps are not in CLOSED position.

Spreader side shiftt


The conditions that allows this function is:
1. to press side shift left / right button

Spreader rotation
The condition that allows this function is:
1. to press rotation clockwise / anticlockwise button

12
LMS Plus FDC– V 72

Spreader 20 – 30 – 40 feet
The condition that allows this function is:
1. to press 20 or 40 button
2. forty seconds timeout

With a “BYPASS 20 40” inserted is necessary to keep pressed the 20, 40 button
to retracts and extends the boom.

13
LMS Plus FDC– V 72

Other controls
1. Working lights control
If engine is idle for over a time limit (adjustable), LMS Plus shuts all working
and standard lights off, in order to preserve alternator life from high current
absorption.
2. Brake oil pressure on/off control
A message on the display appears when a low brake oil pressure sensor finds an
alarm.

14