DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR

Electrical Specification
Impedance 50 Ω
IM3 (2 x 20 W) 1) ≤ -160 dBc / typ. -165 dBc
1) Jumper cables with improved IM3 values are available on request.

VSWR 2) Length ≤ 6 m Length > 6 m


Frequency range straight/ straight/ right angle/ straight/ straight/ right angle/
straight right angle right angle straight right angle right angle
≤ 960 MHz ≤ 1.05 ≤ 1.06 ≤ 1.07 ≤ 1.07 ≤ 1.08 ≤ 1.09
typ. 1.03 typ. 1.04 typ. 1.05 typ. 1.04 typ. 1.05 typ. 1.06
≤ 2,200 MHz ≤ 1.06 ≤ 1.08 ≤ 1.10 ≤ 1.08 ≤ 1.10 ≤ 1.12
typ. 1.05 typ. 1.06 typ. 1.07 typ. 1.06 typ. 1.07 typ. 1.08
≤ 2,700 MHz ≤ 1.10 ≤ 1.12 ≤ 1.14 ≤ 1.12 ≤ 1.14 ≤ 1.16
typ. 1.06 typ. 1.07 typ. 1.08 typ. 1.07 typ. 1.08 typ. 1.09
≤ 3,800 MHz ≤ 1.12 ≤ 1.14 ≤ 1.16 ≤ 1.14 ≤ 1.16 ≤ 1.18
typ. 1.10 typ. 1.11 typ. 1.12 typ. 1.11 typ. 1.12 typ. 1.13
≤ 5,825 MHz 3)
≤ 1.18 ≤ 1.20 ≤ 1.22 ≤ 1.20 ≤ 1.22 ≤ 1.24
typ. 1.14 typ. 1.16 typ. 1.18 typ. 1.15 typ. 1.17 typ. 1.19
2) The given VSWR values are maintained within all global cellular frequency bands.
3) Extended frequency range for premium quality. Please specify before order.

960 MHz 2,200 MHz 2,700 MHz 3,800 MHz 5,825 MHz
Insertion loss, 11.56 dB/100m 18.64 dB/100m 21.06 dB/100m 25.90 dB/100m 33.79 dB/100m
nominal
(20 °C cable temperature values
without connectors, typ. connector
attenuation is ≤ 0.01 dB)
Template TD-00006B

max. Power rating 0.91 kW 0.56 kW 0.49 kW 0.42 kW 0.31 kW


(40 °C ambient temperature)

SPINNER GmbH │ www.spinner-group.com │ [email protected] 1/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR


Mechanical Specification
Minimum bending radius Single / repeated bending radius 25 mm / 32 mm
Crush resistance 20.4 N/mm
Recommended clamp spacing 800 mm
Cable jacket PE black (grey jacket available on request)
Nominal outer jacket diameter 13.7 mm
Connector Material Surface
Inner conductor Cu-alloy Ag-plated
Outer conductor Cu-alloy Ag-plated
Other metal parts Cu-alloy Ni-plated
Insulation PTFE, PE
Sealing Silicone rubber
Installation instruction M30804
Length definition
> 0.5 - > 1.0 - > 1.5 - > 2.5 - > 4.0 - > 6.0 - > 10.0 - > 15.0 -
Length [m]
1.0 1.5 2.5 4.0 6.0 10.0 15.0 20.0
Tolerances [mm] ± 10 ± 15 ± 25 ± 40 ± 60 ± 100 ± 150 ± 200

Environmental Specification
Degree of protection IP 68 (0.1 bar / 6 hours / unmated)
IP 68 (1 bar / 1 hour / mated)
Recommended temperature
range Storage Installation Operation
SF 1/2”-50-PE -70 °C to +85 °C -40 °C to +60 °C -55 °C to +85 °C
SF 1/2”-50-FR -30 °C to +80 °C -25 °C to +60 °C -30 °C to +80 °C
SF 1/2”-50-CPR -30 °C to +80 °C -15 °C to +60 °C -30 °C to +80 °C
Cable jacket
All jacket types (PE, FR and CPR) Halogen free acc. to IEC 60754-1 and IEC 60754-2
SF 1/2”-50-FR Fire retardant acc. to IEC 60332-1, IEC 60332-3.C, IEC 61034 and UL 1581-1991
SF 1/2”-50-CPR Fire class: B2ca, s1a, d0, a1 acc. to CPR: EN 50575
RoHS compliant to directive 2011/65/EU and amendment (EU) 2015/863
Template TD-00006B

SPINNER GmbH │ www.spinner-group.com │ [email protected] 2/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR

Sales article numbers

1) According to IEC 62037-2 and WN 20 000


2) According to EN 10204

Examples, see next page


Template TD-00006B

SPINNER GmbH │ www.spinner-group.com │ [email protected] 3/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR


Sales article numbers – Examples for Jumper
- JL12-7M43RS-2M5
Jumper LF 1/2”, connectors 7-16 male and 4.3-10 male right angle screw type, length 2.5 meter
- JS12-43MS-20F5
Jumper SF 1/2”, connectors 4.3-10 male screw type and pigtail; length 20 feet 5 inch
- JL12-7M7MR-10M-K
Jumper LF 1/2”, connectors 7-16 male and 7-16 male right angle, length 10 meter, 7-16 male right angle
MultiFit connector is kitted to the loose end
Sales article numbers – Examples for measurement cables
- JS38-7M7F-2M-I3
Jumper SF 3/8”, connectors 7-16 male and 7-16 female, length 2 meter, low PIM performance with
≤ -165 dBc, inspection certificate 3.1 per order
- JS12-7M43RS-1M3-I4
Jumper SF 1/2”, connectors 7-16 male and 4.3-10 male right angle screw type, length 1.3 meter, low
PIM performance with ≤ -170 dBc, inspection certificate 3.1 per jumper
Customized jumpers
The jumpers shown above can be customized to meet specific requirements such as grey cable jacket,
extended frequency range, predefined phase length or for measurement purpose. In latter case please
specify required inspection certificate 3.1. In case of low PIM test cables please specify the required IM3
thresholds (e.g. -170 dBc max.).

Figure shows low PIM measurement jumpers with 4.3-10 male screw type and 7-16 interfaces.
Template TD-00006B

SPINNER GmbH │ www.spinner-group.com │ [email protected] 4/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR


7-16 connector system (according IEC 61169-4)
Plug straight Plug right angle Socket

4.3-10 connector system (according IEC 61169-54)


Plug straight (screw) Plug right angle (screw) Socket

Plug straight (hand-screw) Plug right angle (hand-screw)

Plug straight (push pull) Plug right angle (push pull)


Template TD-00006B

Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.

SPINNER GmbH │ www.spinner-group.com │ [email protected] 5/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR


4.1-9.5 connector system (according IEC 60169-11)
Plug straight Plug right angle

N connector system (according IEC 61169-16)


Plug straight Plug right angle Socket

2.2-5 connector system (according IEC 61169-66)


Plug straight Plug right angle PlugSocket
right angle Plu

Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.
Template TD-00006B

SPINNER GmbH │ www.spinner-group.com │ [email protected] 6/7


Data subject to change without notice – Issue K
DATA SHEET Type: J

SpinnerFlex® TopFit Jumper SF 1/2"-50-PE; SF 1/2”-50-FR and SF 1/2”-50-CPR


NEX10 connector system (IEC 61169-71)
Plug straight Plug right angle Socket

Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.
Template TD-00006B

SPINNER GmbH │ www.spinner-group.com │ [email protected] 7/7


Data subject to change without notice – Issue K