Battery Management System

x
BMS Master
x
The new Master in the battery management
system of I+ME ACTIA GmbH represents the core
of a versatile system for the installation, evaluation
and operation of a large diversity of batteries on a
lithium basis.

Applications range from the power wheelchair to


the airship and from the forklift to the hybrid
driven truck/city bus.

x
The Master is always used together with the BMS
c y
Slave or the BMS Slave from I+ME ACTIA GmbH.
The Slave modules are responsible for measuring
the cell voltage, monitoring the temperature and
x
compensating the differences in cell voltage, while The Master provides many different interfaces for
x control and communication:
the Master manages the tasks of system
monitoring, data processing and communication
4
External measuring
with the superior ECUs . c
RS485 for connection with the BMS Slave or BMS
¡
y
Slave incl. cell voltage and temperature monitoring
by hardware
CAN bus for communication with a current/high
¡
voltage measurement module
Interface for different current sensor types
¡

4
Input and output control
8 digital inputs with different characteristics
¡
4 analogue measuring inputs with 2 constant current
¡
outputs for PT100 sensors
1 emergency stop switch
¡
2 wake-up inputs
¡
8 digital outputs for activation of contactors or relays
¡
2 potential-free relay outputs
¡
1 analogue output with 0 ... 10 V
¡
Two independent processors, which mutually 1 PWM output with 0 ... 10 V
¡
monitor each others function and ensure a
redundant control of the output drivers, allow you 4
External communication
to establish a battery management system for CAN bus for communication with other control units
¡
batteries on a lithium basis in a large diversity of
applications. 4
Service interfaces
RS232 interface for communication with a PC
¡
Ethernet interface for representation of system data
¡
and status, as well as for parameter adjustment for
the battery system.
Technical data
General Data Power supply voltage 12 / 24 VDC
Environmental temperature – 20 °C … +70 °C
Weight 1 kg
Dimensions approx. 150 x 230 x 40 mm incl. connector
c y
Interfaces RS485 interface for communikation with BMS Slave or Slave
incl. input for hardware monitoring (voltage surge, over-temperature)
3 x CAN interface for communication with other control systems or measurement modules
Current sensor interface for different types of current sensors
with input for electric surge recognition
Ethernet for diagnosis & service
RS232 interface for diagnosis & service
LEDs BMS-Status
Outputs 8 x high-side switch, 2 x floating relay, 1 x analog,
1 PWM, 2 x constant current for PT100 sensors
for relays, fans and specific applications
Inputs 6 x voltage sensitive, 4 x analog input
2 x current sensitive 1 of which is designed as security input
1 x emergency stop input
2 x wake-up input
Wakeup via CAN, 2 x digital input or time-controlled

Possible battery system setup using BMS Master x

+ PlugIn

Load precharge
IBAT R
measurement

+ Drive
control
Relay

Slave controller
? cell voltage control x
BMS Master
? temp. control
nd
? 2 level security
Relay control

Relay control

- Drive

- PlugIn

Contact
I+ME ACTIA GmbH Tel.: + 49 (0) 531 38 701 0
Dresdenstr. 17/18 Fax: + 49 (0) 531 38 701 88
D-38124 Braunschweig [email protected]
www.ime-actia.de

All data included in this document is intended to be purely used as product information and does not represent or imply any liability with
respect to accuracy and completeness of any data contained herein. Content is subject to technical modification without prior notice. All rights
reserved © 2011 I+ME ACTIA GmbH IR12230C.

You might also like