F1515S1W
F1515S1W
The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice.
E_S-1WR & F_S-1WR B/0-2012 Page 1 of 3
INPUT SPECIFICATIONS TYPICAL CHARACTERISTICS
Item Test conditions Min. Typ. Max. Units
3.3V input 50/420
5V input 30/260
Input current
12V input 12/110 mA
(No load/Full load)
15V input 12/100
24V input 7/55
3.3V input 7
5V input 9
Surge voltage
12V input 18 V
(1S max)
15V input 21
24V input 30
OUTPUT SPECIFICATIONS
Item Test conditions Min. Typ. Max. Units
Output power 0.1 1 W
Line regulation For Vin change of ±1% ±1.1 ±1.5
%
Load regulation 10% to 100% load 10 20
Output voltage accuracy Follow the tolerance envelope graph
Temperature drift 100% full load ±0.03 %/°C Operating Temp.(oC)
Ripple & Noise* 20MHz Bandwidth 100 200 mVp-p
Switching frequency Full load, nominal input 100 kHz RECOMMENDED CIRCUIT
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing D u al Ou tpu t
L L
of Power Converter section, application notes. +Vo
Vin Cout
Cin DC DC 0V
L Cout
ISOLATION SPECIFICATIONS GND
-Vo
Item Test conditions Min Typ Max Units Sin gle Ou tp ut
L
L +Vo
Isolation voltage Tested for 1 minute and 1 mA max 3000 VDC Vin
Cin DC DC Cout
Isolation resistance Test at 500VDC 1000 MΩ GND
0V
Isolation Capacitance Input/Output,100KHz/0.1V 6 15 PF
(Figure 1)
D ual Output
APPLICATION NOTE REG +Vo
Vin REG
The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice.
E_S-1WR & F_S-1WR B/0-2012 Page 2 of 3
OUTLINE DIMENSIONS & pIN CONNECTIONS
[0.366±0.008]
[0.354±0.008]
9.30±0.20
9.00±0.20
[0.528±0.020]
13.40±0.50
(Front View)
1 2 5 6 7 1 2 5 6 7
[0.075±0.008]
1.90±0.20
∅1.00
[0.040]
10.16
0.6±0.10 [0.400]
[0.024±0.004 ] 15.24 Note: grid 2.54*2.54mm.
[0.600]
[0.075±0.008]
1.90±0.20
[0.024±0.008]
[0.700]
0.60±0.20
1.75
(Bottom View)
8.30[0.327]
2.13
[0.084]
[0.012±0.004]
0.30 ±0.10
11.70[0.461]
17.50[0.689]
(Side View)
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life
of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate standards.
4. Only typical models listed, other models may be different, please contact our technical person for more details.
The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice.