Cybenetics Evaluation Report Gigabyte P550B

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH

CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

Lab ID#: GB55001745


Report: 20PS1745A
Receipt Date: Sep 7, 2020
Test Date: Nov 5, 2020 Report Date: Nov 12, 2020

DUT INFORMATION DUT SPECIFICATIONS

Brand Gigabyte Rated Voltage (Vrms) 100-240

Manufacturer (OEM) MEIC Rated Current (Arms) 8-4

Series Rated Frequency (Hz) 50-60

Model Number GP-P550B Rated Power (W) 550

Serial Number SN20233G012792 Type ATX12V

DUT Notes 120mm Rifle Bearing Fan


Cooling
(BK BDH12025S)

Semi-Passive Operation ✗

Cable Design Fixed cables

TEST EQUIPMENT

Chroma 63601-5 x4
Chroma 63600-2 x2
Electronic Loads
63640-80-80 x20
63610-80-20 x2

AC Sources Chroma 6530, Keysight AC6804B

Power Analyzers N4L PPA1530 x2

Sound Analyzer Bruel & Kjaer 2270 G4

Microphone Bruel & Kjaer Type 4955-A

Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2

Tachometer UNI-T UT372 x2

Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD

UPS CyberPower OLS3000E 3kVA x2

Transformer 3kVA x2

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 1/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

RESULTS

Temperature Range (°C /°F) 30-32 / 86-89.6 (+-2℃ / +- 3.6℉)

ErP Lot 3/6 Ready ✓

(EU) No 617/2013 Compliance ✓

115V 230V

Average Efficiency 83.016% Average Efficiency 84.903%

Efficiency With 10W (≤500W) or 2% (>500W) 54.903 Average Efficiency 5VSB 76.447%

Average Efficiency 5VSB 79.648% Standby Power Consumption (W) 0.1906700

Standby Power Consumption (W) 0.0603818 Average PF 0.819

Average PF 0.984 Avg Noise Output 41.55 dB(A)

Avg Noise Output 42.44 dB(A) Efficiency Rating (ETA)

Efficiency Rating (ETA) BRONZE Noise Rating (LAMBDA) Standard

Noise Rating (LAMBDA) Standard

POWER SPECIFICATIONS

Rail 3.3V 5V 12V 5VSB -12V

Amps 18 15 43.5 3 0.3


Max. Power
Watts 108 522 15 3.6

Total Max. Power (W) 550

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 2/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

CABLES AND CONNECTORS

Native Cables
Description Cable Count Connector Count (Total) Gauge In Cable Caps

ATX connector 20+4 pin (560mm) 1 1 18-22AWG No

4+4 pin EPS12V (600mm) 1 1 18AWG No

6+2 pin PCIe (540mm+150mm) 1 2 18AWG No

SATA (510mm+120mm+120mm) 2 6 18AWG No

4-pin Molex (510mm+120mm+120mm) / FDD (+120mm) 1 3/1 18-22AWG No

Modular Cables
AC Power Cord (1400mm) - C13 coupler 1 1 18AWG -

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 3/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

General Data -
Manufacturer (OEM) MEIC

PCB Type Single Sided

Primary Side -
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV

Inrush Protection NTC Thermistor SCK-1R55 (1.5 Ohm)

Bridge Rectifier(s) 1x GBU1006 (600V, 10A @ 100°C)

APFC MOSFETs 2x Jilin Sino-Microelectronics JCS18N50F (500V, 11A @ 100°C, Rds(on): 0.27Ohm)

APFC Boost Diode 1x STMicroelectronics STTH8S06D (600V, 8A)

Bulk Cap(s) 1x Teapo (400V, 330uF, 2,000h @ 85°C, LH)

Main Switchers 2x Jilin Sino-Microelectronics JCS18N50F (500V, 11A @ 100°C, Rds(on): 0.27Ohm)

PFC/PWM Combo Controller Champion CM6805BG

Primary side: APFC, Double Forward


Topology
Secondary side: Passive Rectification & Group Regulation

Secondary Side -
+12V & 5V SBRs 4x Dyelec SBP30V60CT (60V, 30A)

3.3V SBR 1x Jinan Jingheng Electronics SE3045LCT (45V, 30A @ 90°C)

Electrolytic: 4x Chn Cap (3-7,000h @ 105°C, TP), 1x Chn Cap (2-5,000h @ 105°C, TM), 5x YC (105°C, LE), 2x YC (105°C,
Filtering Capacitors
TH)

Supervisor IC Weltrend WT7525 (OVP, UVP, OCP, SCP, PG)

Fan Model BK BDH12025S (120mm, 12V, 0.18A, Hydraulic Bearing Fan)

5VSB Circuit -
Standby PWM Controller PR6249H

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 4/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE


INFO

The PSU`s efficiency under high ambient


temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used

5VSB EFFICIENCY
INFO

This graph depicts the efficiency levels of the 5VSB


rail with 115V and 230V input

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 5/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.231 0.072


1 66.571%
5.137V 0.347 115.16V

0.090A 0.462 0.123


2 73.333%
5.134V 0.630 115.16V

0.550A 2.816 0.327


3 80.365%
5.118V 3.504 115.16V

1.000A 5.104 0.375


4 80.429%
5.102V 6.346 115.16V

1.500A 7.629 0.402


5 80.229%
5.085V 9.509 115.16V

3.000A 15.100 0.463


6 78.344%
5.033V 19.274 115.14V

5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.045A 0.231 0.031


1 47.925%
5.138V 0.482 229.94V

0.090A 0.462 0.049


2 59.767%
5.135V 0.773 229.86V

0.550A 2.815 0.227


3 76.495%
5.117V 3.680 229.86V

1.000A 5.103 0.312


4 78.195%
5.102V 6.526 229.86V

1.500A 7.630 0.390


5 78.232%
5.085V 9.753 229.89V

3.000A 15.099 0.384


6 78.673%
5.033V 19.192 230.25V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 6/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

115V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 7/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

EFFICIENCY GRAPH 115V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 115V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C (+-2 °C) ambient is depicted in this
graph. The X axis represents the load on the +12V
rail(s) while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 8/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

VAMPIRE POWER -115V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 9/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

COMMISSION REGULATION (EU) NO 617/2013 TESTING 115V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

2.748A 1.960A 1.988A 0.982A 54.966 36.17°C 0.830


1 77.695% 1303 34.1
12.140V 5.102V 3.321V 5.094V 70.746 38.39°C 115.31V

6.528A 2.951A 2.988A 1.182A 110.034 36.58°C 0.950


2 83.675% 1340 32.8
12.122V 5.084V 3.312V 5.078V 131.502 39.24°C 115.27V

18.659A 4.941A 5.021A 1.789A 275.044 37.88°C 0.993


5 85.413% 1833 42.3
12.034V 5.059V 3.287V 5.031V 322.018 42.68°C 115.06V

38.637A 9.032A 9.168A 3.038A 549.972 40.29°C 0.992


10 81.434% 2428 48.8
11.912V 4.984V 3.240V 4.940V 675.359 48.65°C 115.10V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 10/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 11/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

EFFICIENCY GRAPH 230V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 230V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C (+-2 °C) ambient is depicted in this
graph. The X axis represents the load on the +12V
rail(s) while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 12/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

VAMPIRE POWER -230V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 13/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

COMMISSION REGULATION (EU) NO 617/2013 TESTING 230V

DC/AC Fan Speed PSU Noise Temps PF/AC


Test # 12V 5V 3.3V 5VSB Efficiency
(Watts) (RPM) (dB[A]) (In/Out) Volts

2.748A 1.961A 1.987A 0.982A 54.967 34.92°C 0.374


1 78.115% 1299 34.6
12.140V 5.102V 3.321V 5.094V 70.367 37.01°C 230.55V

6.528A 2.951A 2.992A 1.182A 110.039 35.27°C 0.526


2 84.382% 1325 34.5
12.121V 5.084V 3.312V 5.077V 130.406 37.77°C 230.68V

18.665A 4.946A 5.022A 1.790A 275.052 37.16°C 0.827


5 87.108% 1834 42.3
12.030V 5.056V 3.286V 5.030V 315.761 41.06°C 230.86V

38.641A 9.035A 9.171A 3.038A 549.991 40.77°C 0.981


10 84.640% 2427 48.8
11.912V 4.981V 3.238V 4.938V 649.802 48.68°C 230.55V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 14/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Gigabyte P550B

Top side Power specifications label

CERTIFICATIONS 115V

Aristeidis Bitziopoulos
Lab Director

CERTIFICATIONS 230V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 15/14
› The link to the original test results document should be provided in any case

www.cybenetics.com [email protected]
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient CYBENETICS LTD
and silent power supplies are promoted Syrou 6, Latsia, 2231, Nicosia Cyprus