DEVO

MOD

7-channel micro camputertsystem

DEVO 7E transmitter Users Manual


Note:Please read the manual throughly before use and keep it in a safe place for the future reference .
Contents

Part one: General information Part two: Helicopter

1.0 General information 2 1.0 System Menu 14


1.1 Important statements 2 1.1 Setup Language 14
1.2 Safety needing attention 2 1.2 Display 14

1.3 Attention before flight 2 1.3 Buzzer Setup 15


1.4 Vibrator Setup 15
2.0 Features 3
1.5 Stick Mode Setup 15
2.1 Transmitter DEVO 7E 3
1.6 Stick Direction 16
2.2 DEVO-RX701 Features 3 16
1.7 Stick Calibration

3.0 Specification 3 1.8 About 16

3.1 DEVO 7E transmitter 3 2.0 Model Menu 16


specification
2.1 Model Selection 16
3.2 Receiver specification 3
2.2 Model Name 17
4.0 Definition of DEVO 7E 4
2.3 Model Copy 17
4.1 Front Panel View 4
2.4 Model wireless copy 17
4.2 Rear View 4 2.5 Model reset . 18
4.3 Wiring Diagram 5 2.6 Type Select 19
4.4 Function keys in panel 5 2.7 Trim System -19

5.0 Control Stick Adjustment 5 2.8 Stick Position Switch -19


2.9 Device select 20
6.0 Neck Strap Usage 6
2.10 Device Output 20
7.0 Stick Mode Switch •6
2.11 Swash Type 21
8.0 Switches between left-hand
7 2.12 Fixed ID 21
and right-hand throttles
2.13 Sensor Setup 22
8.1 Right-hand throttle switched 7
to left-hand throttle
3.0 Function Menu 24
8.2 Left-hand throttle switched 8
to right-hand throttle 3.1 Reverse Switch 24
3.2 Travel Adjust 25
9.0 Training function 8
3.3 Sub Trim 25
10.0 Customized fixed ID 10
3.4 Dual rate and Exponential 25
11.0 Installation requirement 3.5 Throttle Hold 26
11
for receiver
3.6 Throttle Curve 27
12.0 Installation requirement 12
for DEVO 7E battery pack 3.7 Mix to throttle 28

12.1 DEVO 7E Battery Charging 12 3.8 Gyro Sensor 29


3.9 Governor 30 3.0 Function Menu 52

3.10 Swash Mix 31 3.1 Reverse Switch 52

3.11 Pitch Curve 31 3.2 Travel Adjust 53

3.12 Program Mix 33 3.3 Sub Trim 53

3.13 Monitor 36 3.4 Dual rate and Exponential 53

3.14 Fail safe •36 3.5 Throttle Hold 54

3.15 Sensor View 3.6 Throttle Curve .55


' 36
3.16 Trainer 3.7 Differential .56
37
3.8 Balance 58
3.17 Timer 38
3.9 Gyro sensor 59

3.10 Governor 60
MIL 3.11 Aileron to Rudder Mix 60

1.0 System Menu 40 3.12 Elevator to flap mix 61

1.1 Setup Language 3.13 Rudder to aileron/elevator mix 62


40
1.2 Display 3.14 Flap System 62
• 40
1.3 Buzzer Setup 3.15 Aileron to flap mix 63
41
1.4 Vibrator Setup 41 3.16 Program mix 64

1.5 Stick Mode Setup 41 3.17 Monitor .67

1.6 Stick Direction • 42 3.18 Fail safe 67

1.7 Stick Calibration 42 3.19 Sensor View 67

1.8 About 42 3.20 Trainer 68

3.21 Timer 69
2.0 Model Menu 42

2.1 Model Selection • 42 4.0 Upgrading 70

2.2 Model Name 43


5.0 Hot keys usage 70
2.3 Model Copy 43
2.4 Model wireless copy • 43
2.5 Model reset 44

2.6 Type Select .45

2.7 Trim System 45


2.8 Stick Position Switch 45
2.9 Device select 46
2.10 Device Output 47

2.11 Wing Type • 48

2.12 Fixed ID .49

2.13 Sensor Setup 50


deention DEVO 7E

DEVO 7E uses 2.4GHz Direct Sequence Spread


Spectrum (DSSS) technology and features automatic
Part one ID binding, automatic ID assignment, and also features
fixed ID set by yourself. The usage of wireless copy
General function keeps you away from the trouble in wire link-
up. Two mode types of helicopter and airplane are
available to meet your requirements for different models.
information Matrix LCD is used and it offers you convenient
operation. Online update via USB ensures a transmitter
in hand not to be out of date and makes it full of vigour.

DEVO 7E -1
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

1.0 General information

1.1 Important statements


(1) This transmitter is suitable for experienced pilots aged 14 years or more.
(2)All model aircraft must be flown in an approved ground or location.
(3) Walkera accepts no responsibility for damage or injury caused by mis-operation,mis-use or mis-control
after purchase.
(4)We consign our distributors to offer technical support and after-sales service. Please contact your local
distributor for advice or troubleshooting on usage, setup,maintenance, etc.

1.2 Safety needing attention

(1) Far away from people and obstacles.


An RC helicopter in flight has risk of uncertain flight speed
and direction which is potentially dangerous. Please keep
your radio controlled aircraft far away from people, high
buildings, high-tension lines, etc, and avoid operating in rain,
storms, thunder and lightening.

(2) Keep away from humidity


Radio controlled aircraft should be kept away from humidity
and vapor because its complex, precise electronic components
and mechanical parts may be damaged.

(3) Proper operation and maintenance


Use original spare parts to upgrade, modify or maintain your
equipment in order to ensure its safety. Please operate your
equipment within the range of functions permitted. It is
forbidden to use it outside of the safety laws.

(4) Safe operation


Operate your equipment according to your physical status
and flight skills. Fatigue, listlessness and misoperation will
increase the possibilities of accidental hazard.

(5) Protect from heat


The transmitter is composed of precise electronic components
and mechanical parts. Keep it far away from heat sources
and sunshine to avoid distortion, or even damage caused
by high temperatures.

1.3 Attention before flight

(1) Ensure the battery packs of both transmitter and receiver are fully charged.

(2) Ensure both the throttle stick and the throttle trim of your DEVO 7E stay at the lowest positions before
operation.

DEVO 7E -2
Welcome to use the DEVO 7E transmitter
cle(Lnlion
DEVO 7E

(3) Strictly obey the order of TURN-ON and TURN-OFF before operation. When starting your flight, turn on
your DEVO 7E first, and connect the battery to the aircraft last. When turning off the aircraft, disconnect
the battery first, and turn off your DEVO 7E last. An incorrect order of connection or disconnection may
cause the loss of control of your aircraft. Please cultivate the correct habit of turn-on and turn-off .
(4)Ensure whether the directions and actions of all the servos in your RC aircraft are correct when executing
commands of the transmitter. Never operate aircraft with a broken servo as it will result in further damage
to the product or people.

2.0 Features
2.1 Transmitter DEVO 7E
(1) The DEVO 7E uses 2.4 GHz Direct Sequence Spread Spectrum (DSSS) technology and supports both
fixed and automatic ID binding and ID assignment.
(2) USB Online firmware updates permit use of the latest transmitter features.
(3) Adjustable radio power output to improve battery life.
(4)Wireless data transmission between two DEVO 7E simplifies the use of training mode.
(5) 30-model memory data slots available.
(6)DEVO 7E adjusting the gyro sensitivity makes hovering flight and fancy flight in an easy way. AUX2 Gyro
variable gain control makes adjustment for hovering or 3D flight simple.
(7)Ergonomic design provides comfortable and straight forward operation.
(8)DEVO 7E supports software switching between control Modes 1, 2, 3 and 4.
(9)DEVO 7E is suitable for both helicopter and airplane control. In helicopter mode, three flight modes are
available,each one can be individually set and parameters can be configured to support normal, F3C
or 3D aerobatic flight modes as required.
2 .2 DEVO-RX701 Features
(1)Uses 2.4GHz Direct Sequence Spread Spectrum (DSSS) which features instantaneous reaction and strong
anti-jamming protection.
(2)Twin receiving circuits and automatic signal switch automatically effectively ensure the stability of receiving
signal.
(3)Single chip Microco CPU provides super-strong signal analysis and filtering.
(4) Frequency and ID memory maintained by the receiver to simplify and speed up switching battery packs
with transmitter powered on.
(5)Supports setting of Fixed ID or Automatic ID assignment as desired.

3.0 Specification
3.1 DEVO 7E transmitter Specification
.I Encoder 7-channel micro computer system
• Frequency DSSS
• Output power 5 100 mW
• Current drain 5 200 mA (100 mW)
• Power supply 5# Battery 4 X1.5V or NiMH 4 X1.2V 1,600 - 2,000 mAh
• Output pulse 1000 — 2000 Ms (1500Ms Neutral)
3.2 Receiver specification
• Type 2.4GHz 7 channels
• Sensitivity 105 dbm
• Frequency interval a4M
• Weight 11.6 g
• Dimension 43X28X16mm
• Receiver Battery 4.8-6V 1,300mAh

DEVO 7E - 3
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

4.0 Definition of DEVO 7E


4.1 Front Panel view

Antenna

Handle

HOLD Switch FMOD Switch

Eyelet THRO Trim

ELEV/RUDD Stick THRO/AILE Stick

ELEV Trim Power Switch

RUDD Trim AILE Trim

EXT ENT

UP+ R+

DN- L-

LCD Display

4.2 Rear view

Battery Pack cover


MINI USB Socket
Digital Signal
Charge socket Converter
(CHG) socket (DSC)

(1) Charge socket (CHG): input DC at 8-12V, 200 mAh; Polarity: (D)-0
(2) Digital Signal Converter socket (DSC): used for computer based simulator flight practice (requires additional software
and connector dongle available from hobby shops), also can be used for wired training mode.
(3) MINI USB Socket: Used for upgrade the transmitter firmware when the USB combined the PC machine and the transmitter
USB socket.

DEVO 7E —4
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

4.3 Wiring Diagram

Elevator servo

Aileron servo

Antenna Throttle servo


DEVO-RX701

Antenna
Receiver
ror
Rudder servo

4.8v AUX1
Battery 0
Ec T; A U X2
Power
switch

—1 I H
Charge jack

4.4 Function keys in panel


There are 6 function keys in the panel of DEVO 7E. Below are the details:
(1) EXT: Reset key. Press EXT to exit the main menu.
(2) ENT: Confirmation key. Press ENT to access the system or the function mode.
(3) UP+: Moves cursor up to the previous function item.
(4) DN-: Moves cursor down to the next function item.
(5) R+: Moves cursor right to increase the setting value.
(6)L-: Moves cursor left to decrease the setting value.

5.0 Control Stick Adjustmen


The stick adjustment : tension only,here is the steps:
II Remove the left lateral , right lateral left and right non-slipping blocks, respectively.
El Use a screw driver to loosen the fixed screws A, B, C, D, and E, and then remove the base plate.

Left non-
slipping block

left lateral non


slipping block

DEVO 7E — 5
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Find the tension adjuster spring for left and right hand throttle stick as shown below. Using a cross head
screwdriver adjust the screw ringed in red below; clockwise will increase stick tension and counter-clockwise
reduce it. Replace the transmitter rear cover after completion.

Control Stick
Tension Adjustment
Screw(F or G)

Right throttle set Left throttle set

6.0 Neck Strap Usage

T here is a concealed hook in the face panel of DEVO 7E.


It will pop up as you press the hook. The neck strap can
Neck Strap Eyelet be connected to the hook. The Hook Neck Strap Eyelet
located at the center helps to get optimal balance of the
transmitter.

7.0 Stick Mode Switch


There are total four stick modes from MODE 1 through MODE 4. The left-hand throttle includes MODE 2
and MODE 4, and the right-hand throttle includes MODE 1 and MODE 3. Each Mode's configuration diagram
is below:

ti dk ModP ti rk Mode
Mode 1 ode1
M ode 2 NA o d e 2
m 0 Ida :71 Fri NA o d e 3
Mode 4 Mode 4
MODE 2 MODE 4
MODE 2 and MODE 4 are configured for left-hand throttle.

Stir Mode Stick Mode


NA d e 1
Mode 2 Mode 2
m d e :E: Mode '3 144,0:114P.)
Mode 4 Mode 4
MODE 1 MODE 3
MODE 1 and MODE3 are configured for right-hand throttle.

DEVO 7E — 6
Welcome to use the DEVO 7E transmitter
cleention
DEVO 7E

8.0 Switching between left-hand and right-hand throttles


Switching between left and right-handed throttle modes requires both a MECHANICAL and ELCTRONIC switch.
It will work correctly only after both parts are completed. Please follow the steps below :
8.1 Right-hand throttle switched to left-hand throttle
(1) MECHANICAL step
Remove the left lateral and right lateral non-slipping blocks and the left and right non-slipping blocks on
the base plate, respectively.
I Remove the fixed screws A, B, C, D, and E, and then remove the base plate.

Left non-
slipping block

left lateral non


slipping block

Remove the 6 screws and rear cover to expose the base plate. The photo below shows the internal views of
right and left hand throttle setups. Using a cross-head screwdriver loosen and remove, in order, the Linkage
Fixed Screw, Screw F, Screw G and the Throttle Control Spring from the right throttle set, remount the parts
removed into the left throttle set in the corresponding (rotated) positions shown below. Adjust the tension
using Screw F to match your preferred setting. Replace the rear cover.
Linkage Fixed Screw Screw F Screw G Linkage Fixed Screw

1)
i r.
to '

Throttle Control
Spring

—Screw G Screw F

Right throttle set Left throttle s

(2) The ELECTRONIC Step


From the Main Front Panel, press "ENT" button, in the LCD screen, "System" will start to flash. Press the
"ENT" button again to enter the System Menu. Use the UP and DN buttons until flashing "STMOD" appears,
press "ENT" to enter Stick Mode Selection Menu. Use UP or DN buttons until flashing "MODE 2" or "MODE
4" appears. Press "ENT" to confirm and "EXT" button to return to operation mode.
All saved model date will automatically be switched to be compatible with Mode 2 or Mode 4.

k. o d e El] i k. Mode
Mode 1 NA Cl d e
NA 0 d e o e2
tvl o d e ' - :3 A) r4R)
od e e 4
Once both the MECHANICAL and ELECTRONIC steps are successfully completed the transmitter is now
ready for normal operation.

DEVO 7E —7
deention
DEVO 7E
Welcome to use the DEVO 7E transmitter

8.2 Left-hand throttle switched to right-hand throttle


(1)Mechanical Step
Refer to the above(8.1) "Mechanical switch" to remove the transmitter cover.
Remove the 6 screws and rear cover to expose the base plate. The photo below shows the internal views of
right and left hand throttle setups. Using a cross-head screwdriver loosen and remove, in order, the Linkage
Fixed Screw, Screw F, Screw G and the Throttle Control Spring from the right throttle set, remount the parts
removed into the left throttle set in the corresponding (rotated) positions shown below. Adjust the tension
using Screw F to match your preferred setting. Replace the rear cover.
Linkage Fixed Screw Screw F Screw G Linkage Fixed Screw

Throttle Control
Spring

—Screw G Screw F

Right throttle set Left throttle set

(2)The ELECTRONIC Step


From the Main Front Panel, press "ENT" button, in the LCD screen, "System" will start to flash. Press the
"ENT" button again to enter the System Menu. Use the UP and DN buttons until flashing "STMOD" appears,
press "ENT" to enter Stick Mode Selection Menu. Use UP or DN buttons until flashing "MODE 1" or "MODE
3" appears. Press "ENT" to confirm and "EXT" button to return to operation mode.
All saved model data will automatically be switched to be compatible with MODE 1 or MODE 3.

Sti c ode 3 ti k Mode


Miganti Model
mode 2 Mode 2
Mode 3 1:4-41Frl . Mode 3 f4p::1 1'4E')
_ mode 4 E •
Mode 4
Once both the MECHANICAL and ELECTRONIC steps are successfully completed the transmitter is now
ready for normal operation.
Note: Pay careful attention to the force used when removing, replacing and adjusting the screws. Excessive
force may damage them or the base plate.

9.0 Training function


Two DEVO 7E transmitters can be made to work together in order to offer a teachertrainer function, meeting
the requirements for a beginner. The setup of training mode is described below :
(1)Model data transmission
First step is to use the DEVO 7E's wireless data transmission feature to transfer the teacher's main model
data to the trainee's DEVO 7E transmitter. This step guarantees that the model data in each transmitter is
identical. Refer to item "2.4 model wireless copy" in the Helicopter section later in this manual. Two DEVO
7E transmitters are needed for wireless data transmission.
Q16 Eli
(2) Training connection
I CIPLIerAjOil 110 D 1
Insert one end of the signal wire (included) into the DSC
socket of the trainee's transmitter and turn it on. PC 0% will 00 e 00 Connection icon at
be shown in the trainee's DEVO 7E display (see image right). trainee's DEVO 7E
CI MI ij

DEVO 7E —8
Welcome to use the DEVO 7E transmitter
clAntion
DEVO 7E

linkage icon
Turn on the power of the trainer's DEVO 7E. Select the same model as the trainee (as transferred in the
previous section) and briefly fly the aircraft to confirm the settings are good. Turn off the aircraft and turn off
the trainer's DEVO 7E power. Insert the other end of the signal wire into the trainer's DEVO 7E DSC port
and turn on the power once more.

_10n JR/Ilion
Trainee is off and trainer is working Trainee is wo king and trainer is off

c.-1 co: 1.1


4 I I I
Trainer icon
Training status display: when the trainer's icon becomes into "X", the trainee stops flying and the trainer is
working; when the trainer's icon turns into"V", the trainee is flying and the trainer is in leisure.
(3) Usage method
The default setting of the training switch is "R+" key.
During flight, if the trainer press" R+"key, the linkage icon
will be shown as "Ai" that means the control right is moved
to the trainee from trainer. If trainer pushes "R+" key once
again, the linkage icon will be show as "X" that means the
trainer takes back the control right from the trainee.

(4) Setting for training function channels


Trainee is available to get full or part of flight control power to the aircraft model via setting the training function
channel in the trainer's radio. Below is the setting method:
Press the ENT key to enter Main Menu, and then press UP or DN to get access to function menu. Then press
UP or DN to select "training function" and press ENT key to enter Trainer interface. The available channels
are shown below, and the current status of trainer switch is also shown there. Available channels include:
Elevator, Aileron, Throttle, Rudder, Gear, Pitch and Gyro.

Trainer. [El Channel selection:


El e wit° r Press UP or DN to select the channel option; press R or L
Inhibi to select the channel(s) which you want to grant to trainee.
The channels(s) you have selected will be activated as
Aileron "Active". The channel(s) which are not granted to trainee
Inhibit will be kept inhibited. The default setting is "Inhibit".

Press EXT to exit.

DEVO 7E —9
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

10.0 Customized fixed ID


Using the Fixed ID function allows users to create a unique relationship between transmitter model data and
the corresponding model's receiver. It significantly speeds up the binding process and also prevents mistakenly
flying an aircraft with the incorrect transmitter model selected.
(1) Fixed ID setup
To start the Fixed ID setup it is important that the transmitter and receiver have successfully completed automatic
ID binding process. Once the transmitter and receiver are paired a Fixed ID can be set as described below.
Press the "ENT" button on the main panel and a flashing System will display in the LCD. Use UP or DN to
cycle through the options until Model menu appears flashing. Press "ENT" again to enter into Model edit menu.
Press UP or DN until a flashing "FIXID" is displayed, press "ENT" to enter the Fixed ID menu. The current
status is displayed. Use R or L to toggle between modes and set to "ON". Press DN to confirm and enter the
Fixed ID code setting screen.

Fi xe d ID Fi xe d ID
:3 t at u s Off 3 tat u s
C:: 0 dP F Fj

Fi xe d ICI
Press ENT to change the code data, use R and L to change 0n
the code values, press DN to move to the next digit, UP to
t atu s
move to the previous digit. There are 6digits can be settled.
ID Code --' ,1"p

After setting the desired code press ENT, "RUN" will be displayed. Use R or L to change NO to YES and
press ENT to confirm and execute the binding process. An inquiry interface of "Are you sure?" pop up. "ID
Code Matching ... ..." will be shown after press ENT. After binding the display will return to the model menu
automatically.

Fi xe d 1E) ID

Fi Nd 1 D ID NA at° h
1E Are s.iou sure? IC

(2) Cancelling/Resetting the Fixed ID


If you wish to change the receiver Fixed ID model back to random ID, insert the included BIND PLUG into
the output terminal BATT before the receiver is powered on. Connect 5V DC power to the Throttle channel.
The red LED of the receiver will flash slowly. Remove the BIND PLUG. The Fixed ID code has been cancelled.
After the receiver's Fixed ID is reset it should also be reset in the Transmitter. Here is the setup:

In the main interface press the ENT to enter Model


Menu and then press UP or DN to move the navigational
mark to select MODEL MENU. Press ENT to enter
MODEL MENU. Press UP or DN to select Fixed ID code
and press ENT key to enter the Fixed ID code interface.
Press UP or DN to select STATUS option, Press R or
L to change the status to Off. Then press EXT to exit.

DEVO 7E -10
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

11.0 Installation requirement for receiver

Below is some advice on how to install your equipment.


(1) Using 10mm thick foam, wrap the receiver and attach it securely to the aircraft using a cable tie or strong
rubber band. The foam will help protect the receiver.
(2)It is suggested to use rubber grommets and copper washers to isolate the receiver from vibrations. Do not
over tighten the screws in order that the grommets are not damaged otherwise vibration absorption will be
reduced.
(3)When mounting the servos, make sure the servos' bellcranks can move freely over their whole travel range
and ensure the control linkages don't touch or impede the movement of the servos.
(4)If installing additional switches, please install them far away from the engine exhaust pipe and other high
vibration sources. Ensure all the switches move freely over their entire range.
(5)Don't wrap the receiver antennas together or make them parallel; horizontal at 90° will give the best performance.

c40°
t

DEVO 7E - 1 1
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

12.0 Installation requirement for DEVO 7E battery pack

Open the battery cover of DEVO 7E transmitter and take


out the battery box. Insert 4 new cells AA batteries either
Alkaline or full charged NIMH battery into the battery box.
Please double check the polarities are correct and do not
mix old and new batteries.
WARNING:
(1) Inserting the batteries with the incorrect polarity can cause damage to the transmitter and/or batteries.
(2) Do not put the polarities of batteries in the opposite directions.
(3) Fool-proofing must insert correspondingly when battery pack connect to radio, see below:

Anode of the battery Cathode of the battery

Cathode of the battery Anode of the battery


Power fool-proof plug Battery box fool-proof plug

12.1 DEVO 7E Battery Charging


WARNING: The CHG socket is only suitable for use with NiMH batteries. If using alkaline batteries or a LiPO
pack, it is forbidden and dangerous to use the CHG socket.

CHG Charging Socket

Charge socket(CHG):input DC at 8-12V,200mA; Polarity: C1—.)—e

DEVO 7E — 12
DEVO 7E

All the functional settings, which are relative to the


operation system of DEVO 7E itself, are fully
integrated in System Menu. They include Language,
Display, Buzzer, vibrator, Stick Mode, Stick Direction,
Stick calibration, and About. Setup your DEVO 7E
transmitter for the best Helicopter performance with
the following sections. Included are specific functions
for rotor-craft features; Throttle curves, Pitch curves
and Cyclic response are covered below.

In

et,
k_, -_________
-......„.....
,L y am,

0 0 ------
.__
1'1111111Ni II ii MO ."-
miniiiiiiiiiiiiiii II iiiiiiiiiiiiinN,.
,,,

DEVO 7E — 1 3
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

1.0 System Menu


This section describes the settings which are specific to the operation of the DEVO 7E itself. Settings for
Language, Display, Buzzer, vibrator, Stick Mode, Stick Direction, Stick Calibration and About (Firmware) can
all be accessed via the System menu.

Below is the boot screen of helicopter:

Elevator trim Throttle trim


Transmission power display

Battery charge
Tool ii l indicator

1.11-11FayLionliI III [..1 Model name

Timer display

I Model type
display
Throttle percentage
value
-I
Rudder trim display Aileron trim
display

1.1 Setup Language


Choose the native language for the DEVO 7E. Here is the setup: Press ENT to enter System Menu and
then press UP or DN to move the navigational mark to select System menu. Then push ENT to enter System
menu. Press UP or DN to select Language and press ENT to enter the language interface. Press UP or DN
to select the language that you desire. A " 4" will be shown on the screen after selected. Push EXT to exit.

Language Display
C:ontrast
ritf$ 7r 1'1
Dputsch Li 9 htn ess
Fran !E; /10
1.1 Language setup 1.2 Display

1.2 Display
Three items are available to be set for Display:
(1) Backlight contrast: the backlight contrast is adjustable by using UP or DN buttons to move the navigational
mark to the digits after Contrast. Press R key to increase the backlight contrast, while press L to decrease it.
(2) Backlight intensity: the backlight intensity is adjustable using the up or DN buttons. Power consumption
will be increased when intensity is high and battery life will be reduced. When the value is one means
tum off the backlight.
(3) Backlight timeout: the duration for which the LCD stays lit can be configured from 5 to 60 seconds in 5
second intervals or set to "Always On".
Below are the setup:
Press ENT to enter the main menu, use UP or DN to move the navigational mark to select system menu.
Press ENT to enter the System sub-menu, use UP or DN to select Display to enter "DISPL" interface.Press
DN to enter the Backlight time-out setting, use R or L to adjust the period up to 60 seconds, using a setting
of 0 means always on. Press ENT to confirm and EXT to exit to main menu.
Press EXT to exit.

DEVO 7E — 14
Welcome to use the DEVO 7E transmitter
deVention
DEVO 7E

1.3 Buzzer Setup


Pressing ENT to enter the main menu, use UP or DN to select system menu, press ENT to enter System
menu. Use UP or DN to select Buzzer, press ENT to enter the buzzer interface.
(1) [SYSTEM/BUZZE/STATE] Buzzer ON/OFF: Press ENT
button to enter the main menu, press ENT again while
Buzzer
"SYSTEM" is flashing. Use UP and DN until flashing St at u
"BUZZE" is displayed and press ENT. When "STATE"
is shown, press R or L to toggle between ON and OFF
settings. Press ENT to confirm and EXT to exit. Thro tP
(2)[SYSTEM/BUZZE/THSTK] Throttle stick: under the Buzzer
setting menu the option THSTK can be set to ON or
OFF. If the Throttle Stick setting is ON/Active, a musical scale will be heard when moving the throttle stick.
The position of the throttle stick can be judged by listening to the change in musical tone. Setting OFF, turns
off the sounds. After setting the [BUZZE\STATE] setting, press DN until THSTK is displayed. The current
status is displayed, use R or L to change the display between INH and ACT. ACT means tones will be played,
INH means there will be no tones played.
(3) [SYSTEM/BUZZE/TONE] Buzzer tone: the buzzer tone can be selected from 10 notes. You can set the
tone according to your preference. After setting the "THSTK", press DN until "TONE" is displayed. Use
R or L key to change the flashing value between 1 and 10.Press EXT button to exit when finished.
1.4 Vibrator Setup
The DEVO 7E can set Vibrator as an alarm function.
Setup: Press ENT to the Main Menu, use UP or DN to select System Menu. And then press ENT to get the
System Menu, use UP or DN to select Vibrator. Press ENT to get Vibrator setup interface. There are Inhibit
and Active two status. Press R or L to select Active for Vibrator function. Press EXT to exit after finished.

t :21.to r b r ato r

St u S St at u s
Inhibit ......
1,1!

1.5 Stick Mode Setup


There are 4 stick modes including MODE1, MODE2, MODE3 and MODE4. Right-hand throttle includes MODE1
and MODE3; while left-hand throttle includes MODE2 and MODE4. See below setup:
[SYSTEM/STMOD] Stick Mode: from the SYSTEM menu, press UP or DN until flashing "STMOD" is displayed,
press ENT again to enter the stick mode selection sub-menu. Use R or L to select the required stick mode.
Press ENT to confirm the flashing value and EXT to exit to the main menu.

Sti c Mode [St i c k. M ID e


Mode d 1
Mode '2 VMOdeH2
od e 3 f Mode 3 HI 1
mode 4 Mode 4
Stic ode Stic k. l'...d o d
NAode 1 NA odP I
tylode 2 Mode 2
-„ t.y1 0 d e :::
od e 4 'Mode 4
Please refer to 8.0 Switches exchange between left-hand and right-hand throttles.
Press EXT to exit after finished.

DEVO 7E- 1 5
cle(Lnlion
DEVO 7E
Welcome to use the DEVO 7E transmitter

1.6 Stick Direction


Press ENT to enter into Main Menu; Press UP or DN to make
navigation mark at System menu. Press ENT to enter into Stick Direction
System menu; Press UP or DN to choose Stick direction, E IP vp.to r
press ENT to enter into Stick direction interface.
Normal
Stick Direction:There are four items available as Elevator,
Aileron, Throttle and Rudder. Press UP or DN to select the Aileron
stick which will change direction, and press R or L to change Normal
the direction. The factory setting is Normal.
1.7 Stick Calibration
T he stick calibration used to re-calibration when stick unusual.
Enter the System Menu, use UP or DN to select Stick Calibration and press ENT to the Stick Calibration setup
interface. Press ENT to enter Calibration, the display will be as shown below:

Stick Calibration 1:::: al b rati or:


Sili

1.21:011EffilaV I
L:] ENT to Finish

Stick calibration: Move all of the control sticks to their


Stick Calibration maximum and minimum levels several times, when complete,
return the sticks to their neutral positions.
ENT to Calibrate Press ENT again to STOP the calibration process and the
display should show "START: SUCCESS".
If the display shows "STOP:ERROR", the calibration has
b 0 11 failed. Please go back to the STMOD sub-menu using EXT
and re-start the calibration process.
Press EXT to exit after finished.

1.8 About About


From the SYSTEM menu, use UP or DN to choose About ciftwarii:!
and press ENT to enter About interface. The firmware and
Library version will be displayed.
;Et
Press EXT to exit when finished.
Vier, 0:

2.0 Model Menu w


Model Menu manages all the model data saved in DEVO 7E. It includes Model Select, Model Name, Model
Copy, Model Transmit, Model Receive, Model Reset, Type Select, Trim System, Stick Position Switch, Device
Select, Device Output, Swash Type, Fixed ID and Sensor setting.
2 .1 Model Selection
Press ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to get the Model Menu
and press UP or DN to select Model select, press ENT to get the Model Select setup interface.

Model Select
Press UP or DN until the desired model starts to flash. A total
tvl D of 30 model configurations can be stored. Press ENT to
:11 4.3 M 0 D confirm then EXT to exit
4 %F.5 NiUDD 4

DEVO 7E - 1 6
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

2.2 Model Name


In the model name menu, you can edit the model name to 8 characters of your own choosing to simplify
configuration selection next flight session. First, follow step "2.1 Model Selection" to choose the model you
want to rename or edit.
Press ENT to enter the Main Menu, use UP and DN to select NA °del N 3. Fri e
MODEL, press ENT to enter Model sub-menu, press UP or No
DN until "NAME" is in the display. Press ENT again to display
the serial No. (1-30) and current name. Use UP and DN to e
select the characters to be changed, use R or L to change
the selected character. D 2
Press ENT then EXT to finish.

2.3 Model Copy


Press ENT to enter the Main Menu, use UP and DN to select MODEL Menu, press ENT to enter Model
submenu, press UP or DN until " Model COPY" is in the display. Press ENT again to select the source Model.
Use R and L to change the selected model.

Ni1ndPI Cop
0 U r'I_: :7;ourcp:
iNUMEratiaiii/i
7 4- NA 0 D 1 1 MOD 9
r: -6 NicID + MOD 1
Model copy
Press ENT to confirm the destination model into which to
S 0 urCP: 1 M 0 D
copy the current settings. " Are you sure?" will be displayed
as below Illustration, Press ENT to confirm the copy or Dest: 2 M 0 D 1
EXT to exit.
Are you sure?

2.4 Model wireless copy


Model data can be copied wirelessly between two DEVO 7E units using the Model Transmit and Model Receive
functions in the Model menu.
(1) Model Data transmission Model Transmit 1E1
Press ENT to enter the Main Menu, use UP and DN to select
Model Menu, press ENT to enter Model sub-menu, press 2+ nI
UP or DN until " Model Transmit " is in the display. Press
ENT again and use R and L to choose the source model
3 -6 NA D 3
which will be transmitted. 4 t.5 tryl 0 D

Press ENT again to confirm, an enquiry "Are you sure?" will be shown as below Illustration, Press ENT to
transmit, "Transmitting " appears in the interface. Or press EXT to exit.Press EXT to exit after another
DEVO 7E received the data.

1
t',1- IdeI Tran mit Model Transmit
KHA vei "=c k A
1\lo. 1 No, 1
Trari:3111ittirlg
..=;ureT

DEVO 7E-17
deVention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(2) Model Receive


To receive model data, first select the model into which data should be copied, follow the process of model
selection described previously. Model receive can overwrite an existing configuration so be sure to select carefully.
Press ENT to enter the Main Menu, use UP and DN to select Model Menu, press ENT to enter Model submenu,
press UP or DN until Model Receiving is in the display. Press ENT again to confirm. An enquiry information
"Are you sure?" will be shown as below Illustration, press ENT to confirm the reception, press EXT to exit.
Cu
l

Model R c e After pressing ENT to receive, the display shows "Connecting


" in the interface. The information of "Received" with
,r p 0 :=; u r ? the model name will be shown after receiving is finished.
REMOPOMEEM.PIIIIIM40.1,11M111,1.1111111MMIITIVIIITIMIPTIMMTHIMPIIMIMII Or press EXT to exit.

Model Receive 1E1 rylodel Receive


1 4,?3, rd 0
4° NA D

4 '.Ff. MOD 4
Press UP or DN to choose the save position, an enquiry model RPcPiryie
information "Are you sure?" is shown after press ENT. Press .we , .Z7 It n
ENT to save or press EXT to exit. Nr_l, 1
After saving is complete the system will return to the main
menu.
01E)
Press EXT to exit after finished. ,re E u u r ?
2.5 Model reset
Using the Model Reset function the settings for one or all models can be reset to the factory defaults.
It is possible to store up to 30 models data in the model list of DEVO 7E equipment. There are two methods
to reset the model data: batch reset and single reset. Here is the setup:
Press ENT to enter the Main Menu, use UP and DN to select MODEL, press ENT to enter Model sub-menu,
press UP or DN until "Model Reset" is in the display. Press ENT to get Model reset setting interface. Use R
and L to select "ALL" for all models or the individual model name for a single model reset.

Model All

After selecting ALL or a specific model, press ENT, "Are you sure?" enquiry is displayed, press ENT to confirm
or EXT to cancel.

Model Reset Ne10 11P1 Reset


P. .4.-..-I.-.I e, 1 1
Nip, 1
Miod Ad I
Cji [:1 '71
Are s,iou s r s? A r e ou sure-

Press EXT to exit after finished.

DEVO 7E — 18
Welcome to use the DEVO 7E transmitter
cle(Lnlion
DEVO 7E

2.6 Type Select


This transmitter offers a choice of two model types. The Type Select 1E1
options are helicopter and airplane.
Press ENT to Main Menu, press UP or DN to select Model
Menu. Press ENT to enter and press UP or DN to select
Type Select and press ENT to enter Type select interface.
Use UP or DN to select Helicopter or Airplane, press ENT
to confirm, then press EXT to exit.
2.7 Trim System
The Trim System permits the user to fine tune the following items: Elevator, Aileron, Rudder, Throttle. The trim
step is divided in to 20 (factory default is 4). Using small values, permits fine trim control, larger values make
larger adjustments for each 'click' of trim. the procedure to adjust the trim step is as follows:
Press ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to enter and press UP
or DN to select Trim System, press ENT to enter setting interface. Use UP or DN to select Elevator,Aileron,Rudder
and Throttle. Use R or L to change the step value.Press ENT to confirm and EXT to exit.

Tri rn i~i s.iste Tri rn :3.:ferri


Elevator Rudder

..111--! 19 1 Throttle
4/ 20 4/20
Press UP or DN to select the trim which will set, press R to increase the trim value and press L to decrease.
For elevator, aileron and rudder, there are two more options : Normal and Limited. Press R or L you can
change the setup. " Normal: means the trim is always working although th corresponding stick stays anywhere.
"Limited" means the trim is out of working when the corresponding stick is at maximum position.
The last 3 settings in this menu determine if the trim is applied at full control stick or not. This can prevent
servo binding at maximum extents. When "NORM" is displayed, the trim setting is always applied, even at
100% travel. "LIMIT" setting, means that the trim is not applied when the control stick is a full travel. Default
is "NORM". Press ENT to confirm, EXT to exit.

Tri iyiste in
Ee I
No rrri al
Aileron

Press EXT to exit after finished.


2.8 Stick Position Switch
According to the following setting, the switch can be used as a switch. The turn-on or turn-off position at which
stick stays can also be settable.
Setup:
Press the ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to get Model Menu
and press UP or DN to select Stick Position Switch, press ENT to get Stick Position Switch setting interface.

Position :3
it c:
up. 7,51a There are four options under the Stick postion switch: SPSO,
SPS1,SPS2,SPS3. Press R or L to choose the switch you
C: hannel want to define.
is

DEVO 7E— 1 9
gention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Press UP or DN to inhibit channel in navigation mark, and press R to expand the menu.The channel includes
four items: Elevator, Aileron, Throttle and Rudder. The factory default is Inhibit. Take Elevator for example.
Press R or L to choose the Elevator as stick, then Press DN to move nagivation mark to value of position.
It's possible to adjust the stick position via pressing R or L.

Stick. Position 3 %.A.° ;tic k. P o s it ion 3w„,


W I tr h Position
1_I Vy'
Channel n
Elevator
Press DN to navigate the OPEN setting, press R or L to change the direction of the channel stick.
Press UP or DN to navigate the STATUS, which can check the sketch map of the stick OPEN/CLOSE direction.
Check if it was set correctly.
. ..... -

r dw. u !Hui
Position

0n
110i::. I-) OS iti 0 11 ;',;,r
3 t l.t ij
On
l If
g

Up
After finished the setting, press EXT to exit.
2.9 Device select
This setting allows customization of the various function switches. The switches Flight Mode (top right comer) and
Throttle Hold (top left corner) can accept custom settings. Stunt Trim mode can also be defined under this sub-menu.
Setup:
Press ENT to enter Main Menu, press UP or DN to move navigation mark to select Model menu. Press ENT
to enter Model menu function. Press UP or DN to select Device Option. Press ENT to Device Option interface.
(1)Flight Mode Switch:Press UP or DN to move navigation
De ehE ct mark to Flight Switch and press R or L to select the
Flight 3i desired switch,there are both FMOD SW and HOLD
SW,. The factory default setting is FMOD switch.
(2)Stunt Trim Mode: There are two option modes, Common
:::;tu nt Tr; RI and Flight Mode. In Common Mode, all the trim values
C 0 111 m 0 n settings are applied the same to each Flight Mode. In
Flight Mode, the trim value can be set and remembered
differently for each of the 3 available Flight Modes. The default is common.
Setup:
Press UP or DN to choose the Stunt trim select, press R or L to select "Common"or Flight Mode, the factory
default setting is Common.
(3) Throttle Hold Switch: Refer to "(1) Flight Mode switch"
After finishing the setting, press EXT to exit.
2.10 Device Output
Device output can set up the output switches respectively. It can also activate, inhibit or use other functions.
. _
Setup: R 01_0 IJt
Press ENT to enter main menu, press UP or DN to move G ar
navigation mark to Model Menu. Press ENT to enter Model
Menu. Press UP or DN to select Output Device and press
HOLD SW
ENT to enter Output Device interface. Fu rti 0 n
There are 2 settings:Gear, AUX2. ti

DEVO 7E - 20
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(1) Gear
Press UP or DN in output interface can change the GEAR Switch. It includes FMOD SW, HOLD SW, SPSO SW,
SPS1 SW, SPS2 SW, SPS3 SW. Press R or L to select the setting switch, The default setting is HOLD SW.
Press UP or DN to select Function Setting after you select the switch,Press R or L can enter the interface of Gear
activate, inhibit, Gyro and Govemor. The default setting is Activate. You can continue to set other items after finishing.

D e e 0Lb ut D N wj C utp ut
G e ar Gear
HOLD 3W HOLD
Fun cti o n Functio
Acti'y'e
(2) AUX 2
Press UP or DN to enter the AUX2 interface.Press R or L can change the AUX2 switch. It includes FMOD
SW, HOLD SW, SPSO SW, SPS1 SW, SPS2 SW, SPS3 SW. The default setting is FMOD switch.

r
Press UP or DN to select the Function Setting, press R or L to choose the switch, it inculdes Inhibit, Active,
Gyro, Governor. The default setting is Gyro.

De vi c e utp ut Device Output


Al X2 A U :>:2
Ft
Fu n ct 0 11
ti
r)E)1.. 1
After finishing the setting, press EXT to exit.

2.11 Swash Type


The Swash Type menu features five options: 1 Servo Normal, 2 Servos 180°, 3 Servos 120°, 3 Servos 140°
and 3 Servos 90°.
Setup: Press "ENT" to enter Main Menu, press UP or DN until "MODEL" flash , and then press "ENT" to enter
Model Menu; Press UP or DN to choose "SWASH" press ENT enter to Swash setting interface.

I I I ::11-

Press UP or DN to choose the required swashplate type.


Press ENT to confirm, the corresponding items will have
SPryo 1 2 Cr the "V" mark in front of the items.Press EXT to exit after
finishing.
3 Servo E.; 1 4 Cr

2.12 Fixed ID
Using the Fixed ID function allows users to create a unique relationship between transmitter model data and
the corresponding model's receiver. It significantly speeds up the binding process and also prevents mistakenly
flying an aircraft with the incorrect transmitter model selected.
(1) Fixed ID setup
To start the Fixed ID setup it is important that the transmitter and receiver have successfully completed automatic
ID binding process. Once the transmitter and receiver are paired a Fixed ID can be set as described below.
Press the "ENT" button on the main panel and a flashing System will display in the LCD. Use UP or DN to
cycle through the options until Model menu appears flashing. Press "ENT" again to enter into Model edit menu.
Press UP or DN until a flashing "FIXID" is displayed, press "ENT" to enter the Fixed ID menu. The current
status is displayed. Use R or L to toggle between modes and set to "ON". Press DN to confirm and enter the
Fixed ID code setting screen.

DEVO 7E - 21
clAntion
DEVO 7E
Welcome to use the DEVO 7E transmitter

Fi xe d I D Fired I D
St atu s Off Statu On
Ir I c 0 d p 0 J 1 0 0
ij ij

Press ENT to change the code data, use R and L to change Fixed ID
the code values, press DN to move to the next digit, UP to
move to the previous digit. There are 6digits can be settled. p.tu •• I
After setting the desired code press ENT, "RUN" will be
displayed. Use R or L to change NO to YES and press ENT I D I.. 0 CI e
to confirm and execute the binding process. An inquiry
interface of Are you sure?" pop up. "ID Code Matching ...
..." will be shown after press ENT. After binding the display will return to the model menu automatically
Fig'...:: .
I Fixed ID

I ID ! 1:1 ;RI h

Are vou

(2) Cancelling/Resetting the Fixed ID


If you wish to change the receiver Fixed ID model back to random ID, insert the included BIND PLUG into
the output terminal BATT before the receiver is powered on. Connect 5V DC power to the Throttle channel.
The red LED of the receiver will flash slowly. Remove the BIND PLUG. The Fixed ID code has been cancelled.
After the receiver's Fixed ID is reset it should also be reset in the Transmitter. Here is the setup:

In the main interface press the ENT to enter Model


Menu and then press UP or DN to move the navigational
mark to select MODEL MENU. Press ENT to enter
MODEL MENU. Press UP or DN to select Fixed ID code
and press ENT key to enter the Fixed ID code interface.
Press UP or DN to select STATUS option, Press R or
L to change the status to Off. Then press EXT to exit.

2.13 Sensor Setup


Press ENT enter to the Main Menu. Press UP or DN to select the Model Menu. Press ENT enter to Model
Menu. Press UP or DN to select sensor press ENT enter to the sensor setting interface. See the Illustration.

Pnsor vetting 477


Press R or L to select Activate or Inhibit (the default setting
Sensor St at u is Inhibit), such as press Activate will includes No Signal
Waming, Voltage sensor, Temperature sensor, GPS receiver
setting etc.

Sensor Setting Cri


b

(1) No Signal Warning :-; 11.! n :.:.; or St at u s


Press UP or DN to make the navigation mark to choose "No .6,1:: ti v P
Signal Warning". Press R or L to choose "Inhibit" or "Active" I'd o :z.; i g n a.I Iii
i n !::::1
(default setting is" inhibit"). If you choose "Active", the Radio
will alarm when telemetry signal lost. As following: 1 Mininiiiiiig 1

DEVO 7E — 22
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(2) Voltage Setup


There are 3 different types of voltage can be measured.It includes Internal 5V,External V1 and V2 which can
be monitored two different external voltage(i.e. battery) respectively. Once the measured voltage is lower
than the setting value, the Radio will alarm.
(2.1) Receiver 5V(Internal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3.6-6V
Voltage Setup: press R or L to activate the 5V, the alarm interface will appear in the interface, please refer
to the Illustration.

VO 'tag P IItS,!3
aq 13
Internal: 5 Internal: 5%.,

711111111
6
Press UP or DN to select the Alarm Voltage setting, press R or L to set the value. The range is 3.6-6V. you
can continue to set other items after you finished.
(2.2) External V1
Press UP or DN enter to External V1 setting interface. Press R or L to activate the V1, the details refers to
the Illustration.

1_11 IC1..-1 C: VO e
Externa.1: E."'i EMernal:
Act' %le
e Al arrri Vo flag e
nit 3.6 Unit
Press UP or DN to select the Alarm Voltage setting. Press R or L to set the value. The setting range is
0.2-99.9V. you can continue to set other items after you finished.
(2.3) External: V2 setting can refer to External V1 setting.
Press EXT back to sensor setting interface after you finished.
(3) Temperature sensor
The temperature sensor can measure up to 4 different temperature(i.e.motors). You can choose Celsius or
Fahrenheit. The alarmed value can be setted to 4 different temperature. Once the measured value is higher
than the setting value, the radio will alarm. The Alarm Temperature value can be setted as -20-220°C or
-4.0-428.0° F.
Te MP erature ui
Temperature Setup:
In the "Sensor Setting" interface, press UP or DN to make
the navigation mark to choose "Temperature Sensor", and T1
press ENT to enter "Temperature Sensor" setting interface. Inhibit
See the illustration.

(3.1) Unit
T2 Inhibit

Press UP or DN to make the navigation mark to choose "Unit" setting item, and press R or L to choose Unit,
two kinds of Unit:Celsius and Fahrenheit.
(3.2) Alarm Temperature Setup
Press UP or DN select the T1, Press R or L to activate the Temperature 1E53
setting.lnhibit will change to Active and Alarm temperature s
will be shown. If you choose Inhibit, the Alarm temperature
value won't be shown. Ti Acti'v'e
Press UP or DN to select "Alarm" setting, press R or L to Alarm
set the alarm temperature value. Press UP or DN to set
other items after finishing the setting. Irihibit

DEVO 7E -23
clAntion
DEVO 7E
Welcome to use the DEVO 7E transmitter

(3.3) T2,T3,T4 Setup


Refer to the step of "(3.2)T1".
(4) GPS Setup
There are 4 items including Altitude Type,Speed Unit,Date Type and Time Zone in the GPS receiver setting
interface.

Press UP or DN to select the Sensor setting interface


to enter the GPS setting interface. Altitude Type
Abs
GPS Setting Speed Unit
Altitude Type INM
Relat
(4.1) Altitude Type
Speed Unit Press UP or DN to select the Altitude type on the GPS
k:rI setting interface and it's Absolute and Relative.

(4.2) Speed Unit


Press UP or DN to select the Speed Unit on the GPS setting interface and it includes knots and km/h and
relative. Select the desired item.

GPS 'Setting GP 9
Altitude Type Altitude Type
Relative A e I at:
Speed Unit Speed Unit
knot '
(4.3) Date Type
Press UP or DN to select the Date Type on the GPS setting interface and it includes DD-MM-YY, MM-DD-
YY and YY-MM-DD. Select the desired item.
(4.4) Time Zone
Press UP or DN to select the Time Zone, press R or L to set the desired Time Zone.

CiF'S Setting (To P Setting orin


Date Type Date Type
DD -.).'°•12
Time 75 Time Zone
UT ;- +RR: 00 UT 1 4-0a 00
(4.3) Date Type (4.4) Time Zone

3.0 Function Menu


The Function Menu allows you to customize the settings for your saved models. This menu includes the following:
Reverse setting, Travel Adjustment, Sub Trim, Dual Rate/Exponential, Throttle Hold, Throttle Curve, Mix to
Throttle, Gyro Sensor, Govemor, Swash Mix, Pitch Curve, Program Mix, Monitor, Fail Safe, Trainer and Timer.

Reverse Switch
3.1 Reverse Switch
Elevator
Press ENT in main interface to enter Main Menu; Press UP iiiiiiiiiiiiii'iiii iiiiiiiiiiiiei
or DN to move the navigation mark to Function Menu. And IMOEa .

press ENT to enter Function Menu, Press UP or DN to Aileron


choose Reverse Switch and Press ENT to enter into Reverse
Switch interface. N o rm al

DEVO 7E - 24
Welcome to use the DEVO 7E transmitter
deVention
DEVO 7E

Press UP or DN to move navigation mark to ELEV(take RP P e Swito h


Elevator for example), Press R or L to shift the status between
nomal and reverse. These are two status for option. And the Elevator
default setting is Normal. All Channels Reverse Switch like:
Aileron, Throttle, Rudder, Gear, Pitch and Aux2 can be
referred to the way of ELEV Reverse Switch. And press EXT Aileron
to exit after finishing setting.
3.2 Travel Adjust
Press ENT to enter into Main Menu. Press UP or DN to move navigation mark to select item Function Menu.
Press ENT to enter Function Menu. Press UP or DN to select Travel Ajust, Press ENT to enter Travel Adjust
interface, as below illustration. It shows the Travel Adjust status of one channel:

Travel Adjust
Elevator Take ELEV for example, Press UP or DN to move navigation
to desired item Elevation of U. Press R or L to increase or
decrease the servo travel range. The adjustment range is
from 0.0% to 150.0%. The factory default is 100.0%.
D uu,

Press UP or DN to move navigation mark to desired item D of ELEV. Press R or L to increase or decrease
the servo travel range. The range is from 0.0% to 150.0%. The factory default is 100.0%.
All other channel's Travel Adjust like Aileron, Throttle, Rudder, Gear, Pitch and Aux2 can be referred to ELEV
travel Ajust. Press EXT to exit after setting finished.
3.3 Sub Trim
NOTE: Sub Trim is used to fine tune the servo neutral position during setup. In order to avoid pushing the
servo beyond it's limits and possibly causing damage it is advised to first mechanically adjust the servo arm/bell
crank to be as close to the neutral point as possible. Only when this is complete may sub trim be used to
make a final a djustment.
Setting method:
Sub Trim
Elev;=1.to:
Press ENT to enter Main Menu, Press UP or DN to move
the navigation mark to desired item Function Menu. Press
ENT to enter Function Menu, Press UP or DN to select Aileron
Sub trim, and press ENT to enter Sub Trim interface.

The interface show the items and the channels which are adjustable. Press R or L to change the neutral point
of Servos. The default for every channel is 0.0%. The permitted adjustment ranges are show in the table below:

Adjustment range Channel name Adjustment range

Elevator D62.5%--U62.5% Gear -62.5%—+62.5%


Aileron R62.5% —L62.5% Pitch L62.5% — H62.5%
Throttle L62.5% —H62.5% AUX2 -62.5% —+62.5%
Rudder R62.5%—L62.5%

Press EXT to exit after adjustment finished.

3.4 Dual rate and Exponential


Dual Rate/Exponential is a function which permits a change in behavior of the control sticks between pre-
defined settings. Dual Rate alters the maximum and minimum servo travel available, Expo has no effect on
the maximum or minimum travel but decreases or increases the sensitivity to stick movement in an exponential
manner. One use of Dual Rate/Expo is to reduce the sensitivity of the controls when landing.

DEVO 7E-25
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Setting method:
Dual Rate and 1E7.
Press ENT to enter Main Menu. Press UP or DN to move
navigation mark to desired item Function Menu. Press ENT
Channel
to enter Function Menu, press UP or DN to choose Dual Elevator
rate and Exponential, Press ENT to enter D/R and Exponential
interface.
Position
(1) Channel selection
Press UP or DN to move navigation mark of Channel, Press R or L to set up channels containing Elevator,
Aileron and Rudder. Choose the desired channel for setting.
(2) Position selection
Press UP or DN to move navigation mark to desired item Position. In the
manual mode, the function of Dual rate and Exponential will be executed
by the corresponding FMOD switch among PosO and Pos1. Take the item
Elevator at channel as an example, It's possible to shift between PosO and
Pos 1 via pushing or pulling the FMOD switch.

Du 1:::: (3) Dual rate adjustment


Position Press UP or DN to move the navigation mark to desired
item Dual Rate. It's possible to change the dural rate value
Pos 0 of Postion via pressing R or L and the corresponding value
D u al Rate curve in the right top of interface will be changed accordingly.
The factory default is 100%.
100
(4) Exponential
Press UP or DN to select Exponential item of navigation mark. It's possible to change Dual Rate and Exponential
value in Pos when pressing R or L to change the value. There are ± 100% and Line three adjustment. At the
same time, the corresponding curve will be changed and shown at the right graph.
(5) Normal Mode
Press DN to move the navigation mark to "Normal Mode", press R or L to choose PosO, Pos1 and Post.

Dual Rate and CIaaI Rate arid Ex


Dua.1 Rate Expone nti ;al 7
l ily: Li rie
E o ri e nti al N o C in al o d e
PINI177mHymm:1,:
(4) Exponential (5) Normal Mode

(6)Stunt Mode:Refer to "(5) Normal Mode"

Press EXT to exit after finishing the setting.

3.5 Throttle Hold


If the throttle hold function is activated in the function settings menu, it can be operated by the Throttle Hold
switch as shown in the picture below. The permitted setting range is from -20.0% to 50.0%. The default setting
is inhibited.
Setting method:
Press ENT to enter Main Menu, Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Hold, Press ENT to enter Throttle Hold
interface, as below illustration:

DEVO 7E — 26
Welcome to use the DEVO 7E transmitter
deention
DEVO 7E

Throttle Hold Throttle Hold


HO id St atu!=; Hold Slat
RN I'll
ETP
IEEE
P ri F.: I

Press R or L to activate Throttle Hold function, and expansion list will be shown as Throttle hold status, Throttle
hold position and Throttle hold switch.
(1) There are two items under Throttle Hold Status: Active and Inhibit. The factory default setting is Inhibit.
(2) Throttle Hold position
In the Throttle Hold interface, press UP or DN to make the Navigation mark to choose "Throttle Hold Position"
setting options. Press R or L to change data, the minimum value is -20.0%; the maximum value is +50.0%.
(3) Throttle Switch setting
Throttle Hold
It's invalid for setting, the factory default is HOLD switch
which will be shown in the status item. When the Throttle Hold :El 5 it c h
Hold switch is ON, data under the Throttle Hold can not be
amended until Throttle Hold switch to be OFF, and the hold H LL:1 01
status is changed.
Press EXT to exit after setting up finished.

3.6 Throttle Curve


Throttle curve are adjusted through seven points, which of all the flight modes can be respectively set. The
flight mode include Normal Flight, Stunt.
Press ENT to enter main menu, Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Curve, Press ENT to enter Throttle Curve
interface.The enquiry dropdown is shown"All servos hold?" If click OK, all the servos will be locked at the
current status, if click Cancel, all the servos will be unlocked at the current status.

TI-IrottIP Lir? e !ET Throtti e C ij r'...'e


Flight tylode
All 3 e r%"1:-.1 oId? Normal ...
Expo ri e al
L Off
(1) Flight Mode
There are total two flight modes: Normal Flight, Stunt. The Curve of which can be respectively set in their
corresponding flight mode. The setting method is to press UP or DN to select Flight Mode in Throttle Curve
interface. The corresponding flight mode will be shown when the Flight Mode switch shifts via pushing or
pulling the Flight Mode Switch. And the exponential can be adjusted after Flight Mode is selected.

(2) Exponential Adjustment Throttle u ryiP 49.11.1


Press UP or DN in Throttle Curve interface to move Flight Mode II • 11 .
navigation mark of exponential curve and press R or L
to set the exponential function Off and On. The throttle 1%.10ririal
curve will be changed smoothly if touching ON, or in fold Expo e Ital
line if clicking OFF.
I 121113 LI El
(3) Curve setting
It includes two items: Point and Output.

DEVO 7E- 27
ociXention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(3.1) Adjustment for Point


Press UP or DN in Throttle Curve interface to move the navigation mark to desired item Point. Press R, an
expansion list including "-L" "-1", "-2", "-M", "-3", "-4" and "-H" seven points is shown and can be selected via
pressing R or L.

ThrottIP CilrUP 1E1 Throttle Curve


Point I .a Point
Point - L Point - 1
Status
1 Inhibit
(3.2) Status adjustment
Press UP or DN to move navigation mark to Status and press R or L to choose Inhibit or Activate. Click Inhibit
if you don't amend the amount of the selected point. The factory default is Inhibit. Click activate if you want
to amend the amount of the selected point.
(3.3) Output adjustment
An expansion list of Output items will be shown after activating the Status.Press UP or DN to move navigation
mark to select Output item. And press R or L to increase or decrease the amount of selected point with a
minimum of 0.0% and a maximum of 100.0%.

Th roll! e- u rcif:! Ti P I:: Li ryR


St;=itu!::; 0 .n n.0

Active
Status
50, 0% L I HU H
(3.2) Status adjustment (3.3) Output adjustment
Press EXT to exit after finished.

3.7 Mix to throttle


The Mix to Throttle function is designed to permit the main rotor speed to remain constant despite a change
in load when operating the aileron, elevator or rudder. Generally, it is not advised to use this function except
when stunt flying.
Setup:
Press ENT to enter Main menu in the main interface. Press UP or DN to move navigation mark to select
Function Menu. Press ENT to enter function menu. Press UP or DN to select Mix to Throttle. And press ENT
to enter Mix to throttle interface as in below illustration.

Nib< to ThrnttIP There are three settings: elevator, aileron and rudder. If the
Eleiyiator item of Channel is shown as Elevator, there are UP, DOWN
and Switch in the interface. If the item of Channel is Aileron
or Rudder, the contents in the said interface will be changed
Down into Left, Right and Switch. Take the example of Channel
set as Elevator to illustrate the setting method.

(1) Up setting
In the Mix to throttle interface, press UP or DN to move the navigation mark to select UP item. Press R or L
to increase or decrease the mix amount when moving the throttle stick upwards. A positive MIX value means
that as ELEV channel output value is increased (when flying forward), the THRO value will also be increased
automatically.A negative MIX value means that as ELEV channel output value is increased (when flying
forward), the THRO value will be decreased automatically. The available range of adjustment is ±125% .

DEVO 7E — 28
Welcome to use the DEVO 7E transmitter
de(kntion
DEVO 7E

(2) Down setting


Once the values for UP are set press DN to show the current MIX setting for DOWN (ELEV input to fly backwards) .
In the interface of Mix to Throttle, press UP or DN to move the navigation mark to select Down item. Press R or L to
increase or decrease, respectively, the mix amount when moving the throttle stick downwards. A positive MIX value
means that as ELEV channel output value is decreased (when flying backwards), the THRO value will also be
increased automatically. A negative MIX value means that as ELEV channel output value is decreased (when flying
backwards), the THRO value will be decreased automatically. The available range of adjustment is ±125%.
(3)Switch Selection
In the interface of Mix to Throttle,press UP or DN to move the navigation mark of Switch and press ENT to
enter Switch interface. There are Always on, Normal Mode, Stunt Mode options. Press UP or DN to select
the Switch option. Press ENT to make a ".■/ " mark to the choosed switch. Press EXT to the interface of Mix
to Throttle. Puress DN to setup the Aileron or Rudder.
(4)Aileron or Rudder Mix to Throttle setup can be referred to Elevator setting.
Press EXT after finished.
Note:
(1)Before flight, please confirm: All above amount of mix to throttle is proper enough to ensure a good flight.
And make sure all the actions in different flight mode are normal.
(2) The function is in spare when governor is working.
3.8 Gyro sensitivity
This function offers the gain adjustment for gyro sensitivity, which can be manually set through HOLD
switches, and also is possible to be automatically switched among various gains through flight mode switch.
Setup: r pnsor Fit
Press ENT to Main Menu, use UP or DN to choose function
menu. Press ENT to function menu.Press UP or DN to choose NA 0 d e
Gyro Sensor, then press ENT to Gyro Sensor interface.
(1) Manual Setting Channel
(1.1) Manual Setup
In the Gyro Sensor interface, press UP or DN to choose
Mode, there are Manual set and Automatic set for selectable choice. Press R or L to select Manual option.
(1.2) Channel
The factory default channel is AUX2, the Output set offer the function to change other control channels (Refer
to "2.10 Output").
(1.3) Switch Select
In the interface of Gyro Sensor, press UP or DN to choose SWITCH,press ENT to SWITCH, there are FMODSW
and HOLDSW for selectable sets, press R or L to choose the desired switch for Manual control.
(1.4) Sensitivity Setup
There are Position 0 and Position 1 two selection which can set the sensitivity individually.
(1.4.1) POS 0
Choosing MANU and then pressing ENT shows the SWITC status. This indicates the switch to which GYRO
sensitivity settings are assigned. Default is HOLD SW.
r0 Sensor
Pressing DN displays the switch position and assigned
-
GYRO value. The first POS setting displayed is POS 0, I
pressing DN again displays POS 1 . To change the value I HOLD Vii
use the R or L buttons. The GYRO has two modes of
operation; AVCS or NOR. When the value is set greater Id I LI
than 50% AVCS will be activated. AVCS is also knows as
Heading Hold or HH gyro. The bigger the value the bigger
the gyro sensor heading gain becomes, or the harder it tries to maintain the heading.
The NOR mode, also known as RATE mode, is activated by setting the value to less than 50%. The smaller the
value the greater the gyro sensor rate gain becomes, or the harder it tries to maintain a constant YAW rate.
Once POS 0 is set as desired, use DN to set POS 1 setting as required. Typical values are POS 0 = 75%,
POS 1 = 50% . Default values are all 50%.

DEVO 7E - 29
ociXention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(1.4.2) The POS 1 setup is the same as above POS 0.


(2) Automatic setting
r
(2.1) Automatic Setup
Mode
In the Gyro Sensor interface, press UP or DN to choose
Mode, there are Manual set and Automatic set for Auto rnatic
selectable choice. Press R or L to select Automatic option. Channel
(2.2) Channel
V. I I ',.")
The factory default channel is AUX2, the Output set offer the function to change other control channels (Refer
to "2.10 Output").
(2.3) Switch Select :No use in Automatic Setting.
(2.4) Status
Tum the Flight mode Switch or Throttle hold Switch,the status set will display the current flight mode position.There
are Normal Mode, Stunt Mode and Throttle hold available. The Throttle hold need to activate
to use.( Refer to "3.5 throttle hold")
(2.4.1) Normal Mode
Press UP or DN to Normal Mode,press ENT to Normal mode.
Giyiro ::pnsor.
Use R or L to set the value individually. The GYRO has two .z.it at u
modes of operation; AVCS or NOR. When the value is set
less than 50% it is NOR mode. the smaller the value is, the Norm al
greater of the GYRO sensor rate gain becomes,or the harder 1`..1 o rrn e.1 Nlode
it tries to maintain a constant YAW rate. The factory default
value is 50%.
(2.4.2) Stunt Mode and Throttle hold setup refer to Normal Mode.
After finished the setting, press EXT to exit.
Notes: The Gyro sensitivity setting just can be set when there is a gyro menu listed in Output in Mode Menu.(Refer
to "2.10 output")
3.9 Governor
To setup Governor, the Governor needs to be active under the Device Output menu (Refer to section 2.10
Device Output).
The Governor function is a feature which, when enabled, automatically tries to maintain a constant main rotor
speed. It is possible to setup different Governor settings for each flight mode. On the transmitter, the display
is apercentage for reference/adjustment, the actual rotation speed is set by the governor.
Setup: o rn o r
Press ENT to Main menu in the interface, use UP or DN to
choose function menu. Press ENT to function menu. Use UP t atu
or DN to choose Govemor, then press ENT to the Govemor
setting interface, there are status and channels. Press UP or
DN to the Normal Mode, Stunt Mode or Throttle Hold. Channel
6,U
(1)Status
Toggle the Flight Mode or Thottle Stick Lock switch, the status display present flight mode position.There
are Normal Mode, Stunt Mode and Throttle Hold. Throttle hold need to activate.(Refer to 3.5 throttle hold)
(2) Channel: Setup refer to 2.10 Output
G o ye rn o r
( 3) Normal Mode NJ o r m 3.1 NA 1.-J
Press UP or DN to choose Normal Mode, press R or L to
increase or decrease the value. The factory default value is 0%.
Stunt Mode
(4) Stunt Mode and Throttle Hold setup refer to Normal
Mode(3)

After finished, press EXT to exit.

DEVO 7E -30
Welcome to use the DEVO 7E transmitter
de(kntion
DEVO 7E

3.10 Swash Mix


This function, which can be executed through flight mode, is used for amending the variation caused by
s washplate movement, when the aileron or elevator is working.
Press ENT to Main Menu, use UP or DN to choose the navigation mark of enter Function Menu. Press ENT
to Swash Mix interface. The Swash Mix item is only effected after choose the two or more servos in 2.11
Swash Type .Take the third servo 120° as an example.

%Has h tvi Iyv 3. I-1 i


v.;715; 1-1 Tvrie a. s rl T P e
(-7! rvo :E; (21...r:'
Aileron
131r.;;
(1) Swash Type
This function permits the flight adjustment of swashplate behavior.The item is only active when the swashtype
is 2 servos or more in 2.11 Swash Type. The choosed swash type is the 3 servos 120° .
Setup: Enter the FUNCTION menu and select SWHMX. Press ENT to display the first of the available channels
for adjustment and it's current setting value. When swash type is set to 3 servos 120° , four options are
available, ELEV, AILE, PITCH and EXP.
(2) Aileron Mix Adjustment
In the interface of Swash Mix,press UP or DN to choose the navigation mark of Aileron Setting item. Press
R button to increase the rate and L to reduce. If reversed direction, it is available to chang through the "+" or
"-" mark. The adjustable rate is ± 125%. After finished the settings, press DN to set others.
(3) Elevator mix adjustment
The function is based on the 3 servos or more servos which 3 %Nash Mi
is choosed(refer to the 2.11 Swash Type). The setting Aileron
method is same as above.
(4) Pitch Mix Adjustment
The function is based on the 2 servos or more servos which E I e v;Ei.to r
is choosed(refer to the 2.11 Swash Type). The setting
method is same as above.
(5) Exponential Curve
This function can execute the exponential changes, which are set at Dual Rate and Exponential in Function
Menu when it is started. If Off is selected, the exponential curve will be changed in the form of fold line.

3 'was h Mix
Setup:
F' Ito h
Press UP or DN to touch the navigation mark of Exponential
to expand two options: Off and On. the default setting is
E xp o n e nti al Off. On is recommended.
Press EXT to exit after finished.

3.11 Pitch Curve


Pitch curves are adjusted through 7 points, which of all the flight modes can be respectively set. There are
"Normal Mode", "Stunt Mode "and "Throttle hold" 3 flight modes.
Setup:
Press ENT to Main Menu. Press UP or DN to choose Function F' it° h i Li ryie
Menu and then press ENT to enter Function Menu. Press UP Flight t.y.lode OE:
or DN to choose Pitch Curve, press ENT to Pitch Curve
interface, there is "All servos hold?", Press ENT to confirm
with OK for all the servos will be locked at the current states.Or o n e 3.1
use UP or DN to Cancel for Unlocked. Enter the next interface
after confirmed OK or Cancel. Off L I 21i134H

DEVD 7E - 31
ociXention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(1) Flight mode


Press UP or DN to enter the Flight Mode interface of Pitch Curve, The Pitch Curve can be set at the current
state. Setup: Move the flight mode switch, FMOD or HOLD, the state of flight mode will be shown. There are
Normal Mode, Stunt Mode and Throttle hold 3 flight modes. Take Normal Mode as an example for your reference.
(2) Exponential Setup
Press UP or DN to choose Exponential Curve. There are On or Off option.Use R or L to choose On or Off.
The Pitch Curve will become round if choosen ON(Refer to step 3). The Pitch Curve Function stay normal
when choose OFF.
(3) Point Setup
Press UP or DN to enter the setting interface of Curve Point. Press R or L keys of setting curve point,there are
7 points ; point-L, point -1, point -2, point -M, point -3, point -4 and point -H.Choose the desired point for adjusting.
(4) Status Setup
After choosed the curve point, use UP or DN to choose the IP itc h Curve
Status.Press R or L, there are two options, Inhibit and Active PElint
(Remark:When Point choose point -L or point —H, there is
no status shown in the menu).Use R or L to choose Inhibit Point -
If you don't want to change the point data, the factor default t ;Eau s
setting is inhibit. Use R or L to active If you want to change P .v_E r. i 21112 H
the point data. Output will be expanded.
(5) Output Setup
Press UP or DN to choose Output, Use R to increase point's output value, the maximun amount is +100%.
press L to decrease point' output value,the minimum amount is -100%.
(6) There are Normal Mode,Stunt Mode and Throttle hold 3 flight mode. The Pitch Curve can be set respectively
at different models. The setup is same as above. Press EXT to exit after finished.

The basic examples are only for your reference. Adjustment to the real flights is a must.

Throttle curve Pitch curve


100% 100%

75% 75%

50% 50%

25% 25%

0% 0%
L I L 1

Throttle curve Pitch curve


100% 100%

75% 75%

50% 50%
Flight model

25% 25%

0% 0%
L 1 2 M 3 4 H L 1 2 M 3 4

DEVO 7E - 32
Welcome to use the DEVO 7E transmitter
cleention
DEVO 7E

Throttle curve Pitch curve


100% 100%

75% 75%
Flight mode 2

50% 50%

25% 25%

0% 0%
L 1 2 M 3 4 H L 1 2 M 3 4 H

Pitch curve
100%

75%

Autorotation landing 50%

25%

0%
L 1

3.12 Program Mix


There are 8 series of Program Mix, the Mix channels and values are adjustable.
Setup:
Press ENT to Main Menu, press UP or DN to Function Program Mix
interface. Press ENT to Function Menu.Use UP or DN to Program Mix 1
select Program Mix. And press ENT to Program Mix interface.
The current status is Program Mix 1 interface. Use R or L Intlit.lit;H:
to select between 3 options, Inhibited, Normal or Curve. Normal
Take Program Mix 1 memory for example, there are Inhibit,
normal and curve. The default setting is Inhibit.
C Iir v e I
(1) Normal Setting of Program Mix 1
Use UP or DN to select Normal, press ENT to confirm. Then the interface pop up All Servos Hold?" Press
R or L to choose OK or Cancel. If select OK, all the servos will be locked in the current status, if select Cancel,
all servos are unlocked. Press ENT to Program Mix setting interface.

r r;=1.in f.y.1 1 F' rogra.m NAix 1


Master
ry0 s Hold

Eleiyiator
(1.1) Master(Main channel) Setup
Use UP or DN to select Master, press ENT to Master interface. Pressing UP or DN to select the desired
channel, there are Elevator, Aileron, Throttle, Rudder, Gear, Pitch, AUX2, #Elevator, #Aileron, #Pitch, #Rudder,
*Elevator, *Aileron, *Throttle, *Rudder, Flight Mode for choices. Press ENT to make a "q" to confirm the
choosed item. Press EXT to go back to previous Program Mix 1 interface .

DEVO 7E-33
ociXention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(1.2) Slave channel Setup


Press UP or DN to select Slave and press ENT to Slave interface. Use UP or DN to select the desired channel,there
are Elevator, Aileron, Throttle, Rudder, Gear, Pitch and Gyro for choices. Press ENT to make a " -■1" to confirm
the choosed item. Press EXT to go back to previous Program Mix1 interface.

Master
V El e
Aileron Aileron
I ii 17.:! Throttle
A udder Rudder
(1.1) Master(Main channel) Setup (1.2) Slave channel Setup
(1.3) Gain Setup
Once Main and Slave channels have been set, press DN to display the Gain setting. The gain setting controls
the slave channel output in proportion to the main channel setting. A higher gain value will result in a greater
change in output. A negative gain setting will result in a change in the opposite d irection with respect to the
main channel. Take Elevator as an example.
(1.3.1) UP Setup:
Program Mix 1 Mix amount setting when elevator stick moved upward.
p Press UP or DN to move the navigational mark to select Up
to item.Use R/L to increase/decrease the mix amount. It is
possible to reverse mix direction through changing the + or
- sign before amount. The adjustable range is ±125%.
1.3.2) Down Setup:
Mix amount setting when elevator stick moved backward. Use
UP or DN to select Down item.Press R/L to increase/decrease the mix amount. It is possible to reverse mix
direction through changing the + or - sign before amount. The adjustable range is ±125%.
1.3.3) Offset Setup:
Using the Offset function it is possible to apply a slave channel correction even at the 0 position on the main
channel. It is also possible to enable or disable the Offset based on a designated switch position. Press DN
after setting 1.3.2 to display the Offset setting value. Use R and L as before to set the desired value. Use R
and L as before to set the desired value. The permitted adjustment range is -100% to +100%.
(1.4) Switch Selection
Use UP or DN to choose Switch. Press ENT to enter the interface of Switch.There are Always On, Normal
Mode, Stunt Mode,Throttle Hold for permitted choices. Press UP or DN to choose the desired item. Press
ENT to confirm and marked with " .■i ".

ogram VyTt L. 1°1


Offset
0 :TA al
Nilod P
Stunt Mode
Throttle Hold
(2) Curve Setting of Program Mix 1
Use UP or DN to select Curve, press ENT to confirm. Then the interface pop up "All Servos Hold?", Press R
or L to choose OK or Cancel. If select OK, all the servos will be locked in the current status, if select Cancel,
all servos are unlocked. Press ENT to setting interface of Program Mix1. The interface will show the setting
items and curve table as below :

Program Mix 1 ProgrEi.m 1


Master 0
- I '
.e2'%11 si Pr VO H Ohl ? Elevator
M'l . C.: :z;Iavp
L
EIRvator L I 21113 H

DEVO 7E — 34

Welcome to use the DEVO 7E transmitter


de()ention
DEVO 7E

(2.1) Master(Main channel) Setup


Use UP or DN to select Master, press ENT to Master interface. Pressing UP or DN to select the desired
channel, there are Elevator, Aileron, Throttle, Rudder, Gear, Pitch, AUX2, #Elevator, #Aileron, #Pitch, #Rudder,
"Elevator, *Aileron, *Throttle, *Rudder, Flight Mode for choices. Press ENT to make a ".N1" to confirm the
choosed item. Press EXT to go back to previous Program Mix 1 interface .
(2.2) Slave channel Setup
Press UP or DN to select Slave and press ENT to Slave interface. Use UP or DN to select the desired channel,
there are Elevator, Aileron, Throttle, Rudder, Gear, Pitch and Gyro for choices. Press ENT to make a "'1" to
confirm the choosed item. Press EXT to go back to previous Program Mix1 interface.
NA !F..; t r laVb
,./Elevator
leron s'Id e in
Thrutu R Th rottl e
AL] dder Rudder
(1.1) Master(Main channel) Setup (1.2) Slave channel Setup

(2.3) Exponential Curve Setup


Press UP or DN to choose the setting item of Exponential Curve .There are ON or OFF option when you
press the R or L buttoms. The Curve Pitch will become round if the ON buttom is choosen.If you don't adjust
the Pitch Curve Funtion, then choose OFF buttom.
(2.4) Point Setup
Press UP or DN to Point interface. Press R or L to select Point between Point-L,Point -1, Point -2, Point -M,
P oint -3, Point -4 and Point -H. Choose the desired point to adjust.
(2.5) State Setup:
(Remark: When Point choose point -L or point —H, there is no status shown in the menu) After selecting the point
that you want to set, press UP or DN to move the navigational mark to Status item. Press R or L, there are two
options of Inhibit and Active. Select Inhibit for unchanging the current amount (the default setting is Inhibit).

F' ro 9 ram Ni i 1 F' ro 9 ram NA iEn-1J'


Point r
0 t7
POird
Point - 1 P o nt — I
3 t at u 3 Stat u s
Inhibit L 211 3 H 213
14H

(2.4) Point Setup (2.5) State Setup

(2.6) output setting


Press UP or DN to choose Output, Use R to increase point's output value, the maximun amount is +100%.
press L to decrease point' output value, the minimum amount is -100%.
(2.7) Switch Selection
Use UP or DN to choose Switch. Press ENT to enter the interface of Switch. There are Always On, Normal
Mode, Stunt Mode, Throttle Hold for permitted choices. Press UP or DN to choose the desired item. Press
ENT to confirm and marked with " I ".

F' ro 9 ram Mix 1 itc h


0 utp ut r
o
1162121aligillUmi""IN
1 Norm od
O WIL1 .1i Stunt Mode
Throttle Hold
Press EXT to return to the previous interface or press EXT to exit after finished .

DEVO 7E — 35
deUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

3.13 Monitor
The monitor function allows the pilot to monitor the outputs of each transmitter channel.

Press ENT to Main Menu, and use UP or DN to select Function


Monitor
Menu.Press ENT to enter the Function Menu and then use 1
UP or DN to select Monitor and press ENT to enter the monitor
interface for checking the current working status of each I
channel(See rightside View). Press EXT to exit . I
1 I "
3.14 Fail safe
Two options exist if the receiver loses the connection with the transmitter; the first is HOLD - keep the last
action data received, the second is to use a pre-set failsafe value. The default setting is Servo Hold.
Setup: Fail Safe
Press ENT to Main Menu, use UP or DN to select Function
Menu. Press ENT to Function Menu then use UP or DN to EievP.tltr
select Fail Safe and press ENT to enter the Fail Safe
interface.Take the item Elevator as an example to explain.
Use UP or DN to select Elevator on the Fail Safe interface,
then press R or L to change the status of Servo Hold into
Fail Safe(If you want to keep Servo hold status, there is no need to re-set).There is a expanded sub-item
below.Press UP or DN to select 0%,then press R or L to increase or decrease the value, respectively, the
position amount which centers on the neutral point of servo. The available value is 125%,respectively. 0% is
the neutral point of servo.
The setting methods for other channels are same as above.
Fail Safe
Press EXT to exit after finished.
EIRvator NOTE: If the helicopter enters a failsafe mode for any
reason power should be disconnected from the Heli and
Fah e it must be thoroughly checked over before flying again.
Using 100% throttle after a failsafe event may be dangerous
and cause injury or damage.

3.15 Sensor View


The function can be performed by Activate the Sensor Status in the Model Menu, and it is a must that the
receiver also has telemetry function.
Sensor View Setup: Press ENT to enter the Main Menu and use UP or DN to select the Function Menu. Press
ENT to Function Menu. Use UP or DN to select Sensor View, then press ENT to enter the Sensor View
interface. See below views. If all the sensors disconnect, there will be inhibits shown on the view, means the
telemetry signal lost. If all work normal, all the measured data will be shown.
(1) Voltage:Provide 3 diffferent measured voltage values;

'voltage
I rI hiLlit 5, 3 Unit
Inhibit Unit
Inhibit I 0.0 LI nit
(2) Temperature: Press UP or DN to Temperature, which provides 4 different measured temperature values;

Temperature Temperature
0r
Inhibit
") 1 .7., r°,
Inhibit
Inhibit

DEVO 7E - 36
Welcome to use the DEVO 7E transmitter
de()ention
DEVO 7E

(3) Rate Sensor:Press UP or DN to Rate Sensor, which provide 2 different measured RPM values;

Rate n!:; or Rate Sensor


Inhibit 5000FIPM
inhibit LI. 000 R F' NA
(4) GPS Sensor:Press UP or DN to turn to GPS Sensor, show located date,time,longitude, latitude,altitude
and speed;
:-iensor
Inhibit East 1 I ....I .
Inhibit 1.1r1 4805
Inhibit --4, 4 In
Inhibit [1 0 krnilh
3.16 Trainer
To help the beginner pilot it is possible to make two DEVO 7E transmitters operate together using a training
function. The training function permits the teacher to limit or override the controls of the trainee. The instructions
for using the training function are below:
(1) Data copy
The first step is to copy the model settings from the teacher's DEVO 7E to the trainee's DEVO 7E, this guarantees
that the model data in both transmitters is identical. To do this refer to the copy method as described in Helicopter
setup section "2.4 model wireless copy". Once completed, follow the steps below:
( 2) Connection
Insert the signal wire (supplied) into the DSC socket of the
trainee's transmitter.Turn on the trainee's transmitter and the JFIlenlion. C) D 1
display will alternate between showing PC (data connection
01:1 Olj • Connection icon at Ho
mode) and the model name (MOD), see image (right)from rainee's DEVO 7E ..1
the trainer's transmitter into the DSC socket of the trainee's Cl%
transmitter. Tum on the transmitter and a linkage icon will be
shown on the boot screen.
Linkage Display
Next, tum on the Trainer's DEVO 7E. Select the newly copied model data using the MODEL Menu. Bind to
the aircraft and make a small test flight to confirm the aircraft is operating normally. Tum off the power andinsert
the digital signal wire into the trainer's DEVO 7E DSC port. Turning back on the power will automatically put
the DEVO 7E into training mode.

I T..111
-1 I Priton
fr! rrioci 1 e antio n
Trainee is off and trainer is working CIO Trainee is working and trainer is off
1:1% 11 [1 .111111 ,

DEVO 7E-37
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Trainer icon
Training Status Display: when the trainer's icon turns to "X", the trainee stops flying and the trainer is working;
when the trainer's icon turns to",/", the trainee is flying and the trainer is in leisure.
(3) Usage
The default setting of the training switch is "R+" key.
During flight, if the trainer press" R+"key,the linkage icon will
be shown as "-Ni" that means the control right is moved to the
trainee from trainer. If trainer pushes "R+" key once again,
the linkage icon will be show as "X" that means the trainer
takes back the control right from the trainee.
(4)Setting for training function channels
Trainee is available to get full or part of flight control power to the aircraft model via setting the training function
channel in the trainer's radio. Below is the Setup:
Press the ENT to Main Menu, use UP or DN to Function Menu. Use UP or DN to select Trainer and press
ENT to enter Trainer interface. The available channels are shown between Elevator, Aileron, Throttle, Rudder,
Gear, Pitch and Gyro, and the current status of trainer switch is also shown there.

Trainer Channel selection:


Press UP or DN to select the channel option; press R or L
Inhibit to select the channel(s) which you want to grant to trainee.
The channels(s) you have selected will be activated as
"Active". The channel(s) which are not granted to trainee
will be kept inhibited. The default setting is "Inhibit'.
Press EXT to exit.
3.17 Timer
There are two timers on the DEVO 7E, stopwatch and countdown timer. These timers are activated by switch
or by shorcut.
Setup: Timer
Press ENT to Main Menu, use UP or DN to Function Menu.
Press ENT to enter Function Menu. Use UP or DN to choose
Type
Timer, and press ENT to enter Timer setting interface. The Sto watch 11
factory default is Stopwatch, and the timing range of stopwatch
is from 0 to 60.

Timer
Ts,ipe (1) Countdown setting
Press R or L to select Countdown. There is an expand sub-
Countd 14 p.4 ;::”Tjrf
menu Set Time. Press UP or DN to Set Time interface, use
Set Tirm.? R or L to set up countdown time. The timing rang is from
00:10-to 60.

(2) Switch selection


Press UP or DN to move the navigational mark to Switch.There are Inhibit and available switch options, use
L or R to choose switches between FMOD SW,HOLD SW, SPSO SW, SPS1 SW, SPS2 SW and SPS3 SW.
Select the desired item except these items of SPSO SW, SPS1 SW, SPS2, and SPS3 which should be
previously set at Stick Position Switch at Model Menu(refer to "2.8 Stick Position Switch").
Press EXT after finished.
(3) Usage of timer
MOD 1
Use the UP key to start and stop the timer. Use DN to
reset the timer. You can also set switches to control the
timer. Below is the picture of timer display on the boot
screen .

DEVO 7E - 38
deention DEVO 7E

All the function settings, which are relative to the


operation system of DEVO 7E itself, are fully
Part three integrated in System Menu. They include Language,
Display, Buzzer, vibrator, Stick Mode, Stick Direction,
Stick calibration, and About.
Airplane Setup your DEVO 7E transmitter for the best Airplane
performance with the following sections. Included
are specific functions for fixed wing features; Flaps
and Servo Balancing are covered below.

MIIMEN••-_
■ 00

• •

DEVO 7E - 39
cleerdion
DEVO 7E
Welcome to use the DEVO 7E transmitter

1.0 S stem Men


This section describes the settings which are specific to the operation of the DEVO 7E itself. Settings for
Language, Display, Buzzer, vibrator, Stick Mode, Stick Direction, Stick Calibration and About (Firmware) can
all be accessed via the System menu .

Below is the boot screen of Airplane:

Elevator trim hrottle trim


Transmission power display

Battery charge
I~IIII I El indicator

M LID 1 Model name

Timer display
Model type
I
display
Throttle percentage
value

Rudder trim display Aileron trim


display

1.1 Setup Language


Choose the native language for the DEVO 7E. Here is the setup: Press ENT to enter System Menu and
then press UP or DN to move the navigational mark to select System menu. Then push ENT to enter System
menu .Press UP or DN to select Language and press ENT to enter the language interface. Press UP or DN
to select the language that you desire. A "4" will be shown on the screen after selected. Push EXT to exit.

Lang u an e not Display


Contrast

: raiscost_
De LI t Ch
Fr a I-I c: a i

1.2 Display
1.1 Language setup
111116211§11. 1E
Lightness
7/10
1.2 Display

Three items are available to be set for Display:


(1) Backlight contrast: the backlight contrast is adjustable by using UP or DN buttons to move the navigational
mark to the digits after Contrast. Press R key to increase the backlight contrast, while press L to decrease it.
(2) Backlight intensity: the backlight intensity is adjustable using the up or DN buttons. Power consumption
will be increased when intensity is high and battery life will be reduced. When the value is one means
turn off the backlight.
(3) Backlight timeout: the duration for which the LCD stays lit can be configured from 5 to 60 seconds in 5
second intervals or set to "Always On".
Below are the setup:
Press ENT to enter the main menu, use UP or DN to move the navigational mark to select system menu.
Press ENT to enter the System sub-menu, use UP or DN to select Display to enter "DISPL" interface.Press
DN to enter the Backlight time-out setting, use R or L to adjust the period up to 60 seconds, using a setting
of 0 means always on. Press ENT to confirm and EXT to exit to main menu.
Press EXT to exit.

DEVO 7E — 40
Welcome to use the DEVO 7E transmitter
delntionDEVO 7E

1.3 Buzzer Setup


Pressing ENT to enter the main menu, use UP or DN to select system menu, press ENT to enter System
menu. Use UP or DN to select Buzzer, press ENT to enter the buzzer interface.
(1)[SYSTEM/BUZZE/STATE] Buzzer ON/OFF: Press ENT
button to enter the main menu, press ENT again while
Buzzer
"SYSTEM" is flashing. Use UP and DN until flashing t at u s
"BUZZE" is displayed and press ENT. When "STATE"
is shown, press R or L to toggle between ON and OFF 111111Milli
settings. Press ENT to confirm and EXT to exit. Th rOtii e
(2)[SYSTEM/BUZZE/THSTK] Throttle stick: under the Buzzer inhib it
setting menu the option THSTK can be set to ON or
OFF. If the Throttle Stick setting is ON/Active, a musical scale will be heard when moving the throttle stick.
The position of the throttle stick can be judged by listening to the change in musical tone. Setting OFF, turns
off the sounds. After setting the [BUZZE\STATE] setting, press DN until THSTK is displayed. The current
status is displayed, use R or L to change the display between INH and ACT. ACT means tones will be played,
INH means there will be no tones played.
(3) [SYSTEM/BUZZE/TONE] Buzzer tone: the buzzer tone can be selected from 10 notes. You can set the
tone according to your preference. After setting the "THSTK", press DN until "TONE" is displayed. Use
R or L key to change the flashing value between 1 and 10. Press EXT button to exit when finished.
1.4 Vibrator Setup
The DEVO 7E can set Vibrator as an alarm function.
Setup: Press ENT to the Main Menu, use UP or DN to select System Menu. And then press ENT to get the
System Menu, use UP or DN to select Vibrator. Press ENT to get Vibrator setup interface. There are Inhibit
and Active two status. Press R or L to select Active for Vibrator function. Press EXT to exit after finished.

V1 isi I at o r V nato r
St atu Stat. s
11111HuleninsEE
!!!!88—! !I EL

1.5 Stick Mode Setup


There are 4 stick modes including MODE1, MODE2, MODE3 and MODE4. Right-hand throttle includes MODE1
and MODE3; while left-hand throttle includes MODE2 and MODE4. See below setup:
[SYSTEM/STMOD] Stick Mode: from the SYSTEM menu, press UP or DN until flashing "STMOD" is displayed,
press ENT again to enter the stick mode selection sub-menu. Use R or L to select the required stick mode.
Press ENT to confirm the flashing value and EXT to exit to the main menu.

St i c de k. Mode
Mode 1
l o de Niejs .. 111111
ryl o d e 2: 1' 41- .u.1 fsyl 4-411,
Mode 4 Mo d
c:1<. Mode Sti is k. o d e
od e 1 NA o d e 1
1
od e 2 CIIIW
v.' Mode 3 A'1141-*R1 NA 0 d i Ai
T
Mode 4 Mode 4
Please refer to 8.0 Switches exchange between left-hand and right-hand throttles.
Press EXT to exit after finished.

DEVO 7E - 41
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

1.6 Stick Direction


Press ENT to enter into Main Menu; Press UP or DN to make
navigation mark at System menu. Press ENT to enter into
:3ti Direct' 0 11
System menu; Press UP or DN to choose Stick direction, Eleva.to
press ENT to enter into Stick direction interface.
Stick Direction: There are four items available as Elevator,
Aileron, Throttle and Rudder. Press UP or DN to select the Aileron
stick which will change direction, and press R or L to change N 0 rm al
the direction. The factory setting is Normal.

1.7 Stick Calibration


T he stick calibration used to re-calibration when stick unusual.
Enter the System Menu, use UP or DN to select Stick Calibration and press ENT to the Stick Calibration setup
interface. Press ENT to enter Calibration, the display will be as shown below:

Stick:. al i b rati o n Ethi Stick:. Calibration


ENT to Calibrate ENT to Finis

Stick calibration: Move all of the control sticks to their


maximum and minimum levels several times, when complete,
return the sticks to their neutral positions.
ENT to Calibrate Press ENT again to STOP the calibration process and the
display should show "START: SUCCESS".
If the display shows "STOP:ERROR", the calibration has
b r at i o LI C :e: !E;
failed. Please go back to the STMOD sub-menu using EXT
and re-start the calibration process.
Press EXT to exit after finished.

1.8 About
0 LH

From the SYSTEM menu, use UP or DN to choose About


oftvyij,r k
and press ENT to enter About interface. The firmware and r: a
Library version will be displayed.
Li b rary
Press EXT to exit when finished.
r, 0,

2.0 Model Menu


Model Menu manages all the model data saved in DEVO 7E. It includes Model Select, Model Name, Model
Copy, Model Transmit, Model Receive, Model Reset, Type Select, Trim System, Stick Position Switch, Device
Select, Device Output, Swash Type, Fixed ID and Sensor setting.
2 .1 Model Selection
Press ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to get the Model Menu
and press UP or DN to select Model select, press ENT to get the Model Select setup interface.
• ■•

Model Select
1311 Press UP or DN until the desired model starts to flash. A total
2 81- tylf.DD 1 of 30 model configurations can be stored. Press ENT to
tyl D confirm then EXT to exit
4 4F5 tyl D 4

DEVO 7E - 42
Welcome to use the DEVO 7E transmitter
de()ention
DEVO 7E

2.2 Model Name


In the model name menu, you can edit the model name to 8 characters of your own choosing to simplify
configuration selection next flight session. First, follow step "2.1 Model Selection" to choose the model you
want to rename or edit.
Press ENT to enter the Main Menu, use UP and DN to select 'Model NI 8.1111
MODEL, press ENT to enter Model sub-menu, press UP or N o , 1
DN until "NAME" is in the display. Press ENT again to display
the serial No. (1-30) and current name.Use UP and DN to Name
select the characters to be changed, use R or L to change
the selected character.
Press ENT then EXT to finish.

2.3 Model Copy


Press ENT to enter the Main Menu, use UP and DN to select MODEL Menu, press ENT to enter Model
submenu, press UP or DN until " Model COPY" is in the display. Press ENT again to select the source Model.
Use R and L to change the selected model.

M i IlieI C: o p 'y' la; odel C.: 0 ' S'1


Source: 1 MOE:I
vel 4. 1\110 D2 D e !=;t.
›*r # rY•;[l 1 1 4. NA 0 D 2
3 NF5 P.,11 0 D 3 2 4. MOD 1
Ne1ode CoP
Press ENT to confirm the destination model into which to
copy the current settings. " Are you sure?" will be displayed :z; OUrce: 1 NA 0 D
as below Illustration, Press ENT to confirm the copy or D e t: M D 1
EXT to exit.
Are you sure?
2.4 Model wireless copy
Model data can be copied wirelessly between two DEVO 7E units using the Model Transmit and Model Receive
functions in the Model menu.
(1) Model Data transmission rylod I Transmit
Press ENT to enter the Main Menu, use UP and DN to select
Model Menu, press ENT to enter Model sub-menu, press
UP or DN until " Model Transmit " is in the display. Press
r) 4. MOD 1
ENT again and use R and L to choose the source model 3 1/2F_s M 0 D :3
which will be transmitted.
4 -i- M0D4
3
Press ENT again to confirm ,an enquiry "Are you sure?" will be shown as below Illustration, Press ENT to
transmit, "Transmitting " appears in the interface. Or press EXT to exit.Press EXT to exit after another
DEVO 7E received the data.

Model Transmit Model Transmit


N0, 1 No,1
NA 0 D TranS q
re u sure '?

DEVO 7E - 43
cleerdion
DEVO 7E
Welcome to use the DEVO 7E transmitter

(2) Model Receive


To receive model data, first select the model into which data should be copied, follow the process of model
selection described previously. Model receive can overwrite an existing configuration so be sure to select carefully.
Press ENT to enter the Main Menu, use UP and DN to select Model Menu, press ENT to enter Model submenu,
press UP or DN until Model Receiving is in the display. Press ENT again to confirm. An enquiry information
"Are you sure?" will be shown as below Illustration, press ENT to confirm the reception, press EXT to exit.

Model Receiiyie After pressing ENT to receive, the display shows "Connecting
" in the interface. The information of "Received" with
APCRiVP is the model name will be shown after receiving is finished.
- Or press EXT to exit.
Are VO 1..] rey
moan, annum, ..... mran-1.11

NAodel Receliyie Model Receive 1E] 1,


P I
isommemir
I
2 )40 1\110 D 1
l„... Il
:3 '6 ty.1 0 CI 3
4 'Ff. I'v1 0 Li 4
Press UP or DN to choose the save position, an enquiry
information "Are you sure?" is shown after press ENT. Press
ENT to save or press EXT to exit. ,
After saving is complete the system will return to the main
menu.
NA 0
D2
Press EXT to exit after finished. Ar yo u sure '?
2.5 Model reset
Using the Model Reset function the settings for one or all models can be reset to the factory defaults.
It is possible to store up to 30 models data in the model list of DEVO 7E equipment. There are two methods
to reset the model data: batch reset and single reset. Here is the setup:
Press ENT to enter the Main Menu, use UP and DN to select MODEL, press ENT to enter Model sub-menu,
press UP or DN until "Model Reset" is in the display. Press ENT to get Model reset setting interface. Use R
and L to select "ALL" for all models or the individual model name for a single model reset.

Model Reset UE

..../ 1 4. MOD n
2 ›* rvl 0 D 1
c: -6 M 0 D :=1
After selecting ALL or a specific model, press ENT, "Are you sure?" enquiry is displayed, press ENT to confirm
or EXT to cancel.

1.ylodel Reset
h. A .-..-I I All

No,1
NV) D '2
Are you riEr?
Press EXT to exit after finished.

DEVO 7E - 44
Welcome to use the DEVO 7E transmitter
cle(Lnlion
DEVO 7E

2.6 Type Select


This transmitter offers a choice of two model types. The Type Select
options are helicopter and airplane.
Press ENT to Main Menu, press UP or DN to select Model
Menu. Press ENT to enter and press UP or DN to select
Type Select and press ENT to enter Type select interface.
Use UP or DN to select Helicopter or Airplane, press ENT
to confirm, then press EXT to exit.
2.7 Trim System
The Trim System permits the user to fine tune the following items: Elevator, Aileron, Rudder, Throttle. The
trim step is divided in to 20 (factory default is 4). Using small values, permits fine trim control, larger values
make larger adjustments for each 'click' of trim. the procedure to adjust the trim step is as follows:
Press ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to enter and press UP
or DN to select Trim System, press ENT to enter setting interface. Use UP or DN to select Elevator,Aileron,Rudder
and Throttle. Use R or L to change the step value.Press ENT to confirm and EXT to exit.

Trim :3s.istern Trim :3s.istein


Elevator Rudder
42
-.111--:1 Throttle
4/20
Press UP or DN to select the trim which will set, press R to increase the trim value and press L to decrease.
For elevator, aileron and rudder, there are two more options : Normal and Limited. Press R or L you can
change the setup. " Normal: means the trim is always working although th corresponding stick stays anywhere.
" Limited" means the trim is out of working when the corresponding stick is at maximum position.
The last 3 settings in this menu determine if the trim is applied at full control stick or not. This can prevent
servo binding at maximum extents. When "NORM" is displayed, the trim setting is always applied, even at
100% travel. "LIMIT" setting, means that the trim is not applied when the control stick is a full travel. Default
is "NORM". Press ENT to confirm, EXT to exit.

Trim :System Triin 3s.'stern


Eleiyiator Ai 1E.! ro n
.
BM 1
Aileron A LI

Press EXT to exit after finished.

2.8 Stick Position Switch


The Stick position switch can be used as turn-on or turn-off switches
Setup:
Press the ENT to get Main Menu and press UP or DN to select Model Menu. Press ENT to get Model Menu
and press UP or DN to select Stick Position Switch, press ENT to get Stick Position Switch setting interface.

Rtick F' ositi on :31.1..1 €111

'PSO SW There are four options under the Stick postion switch: SPSO,
SPSI,SPS2,SPS3. Press R or L to choose the switch you
Channf:::1 want to define.
I-.
1 111 1-.111

DEVD 7E - 45
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Press UP or DN to inhibit channel in navigation mark, and press R to expand the menu.The channel includes
four items: Elevator, Aileron, Throttle and Rudder. The factory default is Inhibit. Take Elevator for example.
Press R or L to choose the Elevator as stick, then Press DN to move nagivation mark to value of position.
It's possible to adjust the stick position via pressing R or L.

Stir k. Position 1E1 Stick Position Svyi„,


siviyiitch Position
0%
Channel On
. ............. up
Press DN to navigate the OPEN setting, press R or L to change the direction of the channel stick.
Press UP or DN to navigate the STATUS, which can check the sketch map of the stick OPEN/CLOSE direction.
Check if it was set correctly.

1
Stir k. Positio EDI Sticl.:' Position 3i-id
Position

0n
Up -

After finished the setting, press EXT to exit.

2.9 Device select


This setting can help you configure various functional switches. It includes Flight Mode switch, Flight Mode
trim, Throttle hold Switch and Flap Switch select.
Press ENT to enter Main Menu, press UP or DN to move navigation mark to select Model menu. Press ENT
to enter Model menu function. Press UP or DN to select Device Option. Press ENT to Device Option interface.

De'y'ire F-lelect
(1) Flight Mode Switch
Flight Switch
Press UP or DN to move navigation mark to Flight Mode
Inhibit Switch and press R or L to select the desired switch, there
Flight Mode Trim are both FMOD SW, HOLD SW and Inhibit. The factory
default setting is Inhibit.
Com in on
(2) Flight Mode Trim
There are two option modes: Common and Flight Mode. In Common Mode, all the trim values settings are
applied the same to each Flight Mode. In Flight Mode, the trim value can be set and remembered differently
for each of the 3 available Flight Modes. The default is common.
Setup:
Press UP or DN to choose the Stunt trim select, press R or L to select "Common"or Flight Mode, the factory
default setting is Common.
(3) Throttle Hold Switch
Refer to (1) Flight Mode Switch.
(4) Flap Switch Select
Refer to (1) Flight Mode Switch.
After finished the setting, press EXT to exit.

DEVO 7E-46
Welcome to use the DEVO 7E transmitter
cleention
DEVO 7E

2.10 Device Output


Device output can set up the output switches respectively. It can also activate, inhibit or use other functions. There
are FMOD switch, Hold switch, SPSO, SPS1, SPS2, SPS3.
Press ENT to enter Main Menu, press UP or DN to move
De c e C.) !...rt. ut
navigational mark to Model Menu. Press ENT to enter
Model menu. Press UP or DN to select Output device and
I;
HOLD 3W
!ih
press ENT to enter Output device interface.
Below three items can be adjusted: Gear, Flap, AUX2. Fu Lion
(1) Gear
Press UP or DN in output interface can change the gear switch. It includes FMOD SW, HOLD SW, SPSO,
SPS1, SPS2, SPS3. Press R or L to select the setting switch, the default setting is HOLD SW.
Press UP or DN to select Function setting after you select the switch, Press R or L enter the interface of Gear
active, inhibit, Gyro and Govemor. The default setting is Active. You can continue to set other items after finished.

Device Output CI ce Output


Cipar Ci N ar
HOLD 3W HOLD EE y
Function Fun 0 t n
Ac ti EEE

(2) Flap
Press UP or DN to move navigation marks to Function setting below Flap. The factory default setting is System
Output setting.
It's possible to change via pressing L to show Flap Output setting.

Device Output Device Outp Lit


Flap Flap
:E:siste IT! :z:
Fu nction Function
System Active
Press UP or DN to move navigational mark to Flap. Press
R or L to expand the menu including FMOD SW, HOLD Device output
SW, SPSO, SPS1, SPS2, SPS3. The default setting is Flap
HOLD SW.
Press UP or DN to move navigational mark to Function 1111MBEZEI
setting. Press R or L to select the items you want to set Func_.fi o n
up. And the items includes Inhibit, Active and System.
Continue to set up other items after setting finished.
Acti
(3) AUX 2
Press UP or DN to enter the AUX2 interface. Press R or L can change the AUX2 switch. It includes FMOD
SW, HOLD SW, SPSO, SPS1, SPS2, SPS3 The default setting is FMOD switch.
Press UP or DN to select the Function setting, press R or L to choose the switch, it inculdes inhibit, active,
Gyro, Governor, the default setting is Gyro. After finishing the setting, press EXT to exit .

De vicA Output CI Output


,6jj),:°,9
FMOD SW F: ryl ID D F-: I.:hi
Fu ncti on Function
G S.'ro Gyro

DEVO 7E-47
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

2.11 Wing Type


Wing Type is grouped into Nomal, Flaperon, Delta and V -Tail.
Wing Type selection:
Press ENT to enter Main Menu, press UP or DN to move
TS,'P e
navigation mark to Model Menu. Press ENT to enter Model Vy'in9 Type
Menu. Press UP or DN to choose Wing Type, and press
ENT to enter the Wing Type interface. Press UP or DN to
Normal
move navigation mark to Wing Type. Press R or L to choose ' ,'-Tail
Wing Type. The Wing Type are Nomal, Flaperon and Delta.
Inhibit
(1) Flaperon
Press R or L to choose Flaperon under Wing Type.
Below is the sketch map of Flaperon servos' assignment:

Left aileron Right aileron


Connect to the output AUX1 in Receiver Connect to the output AILE in Receiver

(2) Delta
Press R or L to choose Delta in Wing Type.
Below is the sketch map of Delta servos' assignmanet:

Left Aileron Right Aileron


Connect to the output AILE in Receiver Connect to the output ELEV in Receiver
(3)V-tail
Press UP or DN to move navigation mark to V-TAIL under V-Tail interface. There are Inhibit and Active, please
choose Active. V-tail is unadjustable when the Wing type is DELTA.
Below is the sketch map of servos' assignment in V-tail:

Left empennage Right empennage

Connect to the output ELEV in Receiver Connect to the output RUDD in Receiver

DEVO 7E — 48
Welcome to use the DEVO 7E transmitter
deUention
DEVO 7E

(4) Dual channels setup


Dual Channels can be set as Elevator, Aileron, Rudder, or Flaperon. It is of dual channel output function.
The channel, which will be set as dual channel at AUX in Device Output (Refer to "2.10 Device Output"),
should be previously set as Inhibit when the AUX channel is being set.

Setting method: Wing Tiyipe


Channel setup: Press UP or DN to move the navigational 1... 3 -Tai I
mark to item Dual Channels in the interface of Wing Type. Inhibit
Pressing R or L, there are items of Elevator, Aileron, Rudder,
and Flap. We take Elevator as an example. C:1 LI al Channels
Elevator
(4.1) Mate setup: Press UP or DN to move navigational mark to "Mate Channels", press R or L to select the
desired channel in the menu with Inhibitt and the inhibited channels previously set in "Device Output".

Wing T'y' P e
D li a I 1:::: h an nels
EIP v ;RI o r The settings of Aileron, Rudder and Flap in the item Channel
r.,,,1:7-11.1-7:! are same as above.

(5) Twin Engine


This function can be set as twin engine output to meet the requirment for the models, which are powered by
twin engines.
(5.1) Mate setup: Press UP or DN to select "Twin Engine"
n 9 TY P e
setting, press R or L to choose the desired channel in M ate
the menu with Inhibit and the inhibited channels previously
set in "Device Output".
AU
Twin Engine
Press EXT after setting finished.

2.12 Fixed ID
Using the Fixed ID function allows users to create a unique relationship between transmitter model data and
the corresponding model's receiver. It significantly speeds up the binding process and also prevents mistakenly
flying an aircraft with the incorrect transmitter model selected.
(1) Fixed ID setup
To start the Fixed ID setup it is important that the transmitter and receiver have successfully completed automatic
ID binding process. Once the transmitter and receiver are paired a Fixed ID can be set as described below.
Press the "ENT" button on the main panel and a flashing System will display in the LCD. Use UP or DN to
cycle through the options until Model menu appears flashing. Press "ENT" again to enter into Model edit menu.
Press UP or DN until a flashing "FIXID" is displayed, press "ENT" to enter the Fixed ID menu. The current
status is displayed. Use R or L to toggle between modes and set to "ON". Press DN to confirm and enter the
Fixed ID code setting screen.

DEVO 7E - 49
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Press ENT to change the code data, use R and L to change


the code values, press DN to move to the next digit, UP to Axed ID
move to the previous digit. There are 6digits can be settled.
After setting the desired code press ENT, "RUN" will be Status On
displayed. Use R or L to change NO to YES and press ENT
to confirm and execute the binding process. An inquiry
interface of "Are you sure?" pop up. "ID Code Matching ...
ID code 1128188
..." will be shown after press ENT. After binding the display
will return to the model menu automatically.

ID Fixed ID

,6,1..e 1. /C1 1J IJ r ?
-mainnvalummtnumosneimmuus

(2) Cancelling/Resetting the Fixed ID


ID Match

If you wish to change the receiver Fixed ID model back to random ID, insert the included BIND PLUG into
the output terminal BATT before the receiver is powered on. Connect 5V DC power to the Throttle channel.
bJ
The red LED of the receiver will flash slowly. Remove the BIND PLUG. The Fixed ID code has been cancelled.
After the receiver's Fixed ID is reset it should also be reset in the Transmitter. Here is the setup:
In the main interface press the ENT to enter Model
Menu and then press UP or DN to move the navigational
mark to select MODEL MENU. Press ENT to enter
MODEL MENU. Press UP or DN to select Fixed ID code
and press ENT key to enter the Fixed ID code interface.
Press UP or DN to select STATUS option, Press R or
L to change the status to Off. Then press EXT to exit.

2.13 Sensor Setup


Setting method: press ENT enter to the Main Menu. Press UP or DN to select the Model Menu. Press ENT
enter to Model Menu. Press UP or DN to select sensor press ENT enter to the sensor setting interface. See
the Illustration.

-:Prr;nr.
Sensor Status Press R or L to select Activate or Inhibit (the default setting
is Inhibit), such as press Activate will includes No Signal
Inhibit Waming,Voltage sensor,Temperature sensor, GPS receiver
setting etc.

(1) No Signal Warning Sensor Setting


Press UP or DN to make the navigation mark to choose "No
:3Rnsor Status
Signal Warning". Press R or L to choose " Inhibit" or "Active" Active
(default setting is" inhibit"). If you choose "Active", the Radio No Signal 1...Yarning
will alarm when telemetry signal lost. As following:
Inhibit
(2) Voltage Setup
There are 3 different types of voltage can be measured.It includes Internal 5V,External V1 and V2 which can
be monitored two different external voltage(i.e. battery) respectively. Once the measured voltage is lower
than the setting value, the Radio will alarm.
(2.1) Receiver 5V(Internal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3.6-6V
Voltage Setup: press R or L to activate the 5V, the alarm interface will appear in the interface, please refer
to the Illustration.

DEVO 7E - 50
Welcome to use the DEVO 7E transmitter
cleention
DEVO 7E

Voltage 'Volt .g e
Internet 5'v' I rite rn al:
Inhibit
ariTi \loitage
3,6 Unit
Press UP or DN to select the Alarm Voltage setting, press R or L to set the value. The range is 3.6-6V. you
can continue to set other items after you finished.
(2.2) External V1
Press UP or DN enter to External V1 setting interface. Press R or L to activate the V1, the details refers to
the Illustration.

VO a9 P 'tag P
E rn : E•gte rn al:
-3RI:Qiaaii iii
Ac:tivf-
',/ci It 8.9
a 2 Unit
Press UP or DN to select the Alarm Voltage setting. Press R or L to set the value. The setting range is
0.2-99.9V. You can continue to set other items after you finished.
(2.3) External: V2 setting can refer to External V1 setting.
Press EXT back to sensor setting interface after you finished.
(3) Temperature sensor
The temperature sensor can measure up to 4 different temperature(i.e.motors).You can choose Celsius or
Fahrenheit.The alarmed value can be setted to 4 different temperature.Once the measured value is higher
than the setting value,the radio will alarm.The Alarm Temperature value can be setted as -20-220t or
-4.0-428.0° F.
Temperature Setup:
~TeIiiperature
In the "Sensor Setting"interface,press UP or DN to make the pI
navigation mark to choose "Temperature Sensor", and press T1
ENT to enter "Temperature Sensor" setting interface. See
the illustration.

(3.1) Unit Inhibit


Press UP or DN to make the navigation mark to choose "Unit" setting item, and press R or L to choose Unit,
two kinds of Unit:Celsius and Fahrenheit.
(3.2) Alarm Temperature Setup
Press UP or DN select the T1, Press R or L to activate the Terilpii::l Lirre
:1 3ni2.1
setting.lnhibit will change to Active and Alarm temperature C:e Is i Lis
will be shown. If you choose Inhibit, the Alarm temperature 1
i.~ . Actiiy'e
value won't be shown.
Press UP or DN to select "Alarm" setting, press R or L to Alarm 100 c.1
set the alarm temperature value. Press UP or DN to set
other items after finishing the setting.
T2 Inhibit
(3.3) T2, T3, T4 Setup
F' Setting Refer to the step of "(3.2)T1".
Altitude Ts.ipe (4) GPS Setup
$olute There are 4 items including Altitude Type,Speed Unit, Date
PRI:!d j I1 Type and Time Zone in the GPS receiver setting interface.
Press UP or DN to select the Sensor setting interface
to enter the GPS setting interface.

DEVO 7E- 51
clAntion
DEVO 7E
Welcome to use the DEVO 7E transmitter

(4.1) Altitude Type


GP:-; jetting
Press UP or DN to select the Altitude type on the GPS
setting interface and it's Absolute and Relative. Altitude Type
R e alive
Speed Unit
(4.2) Speed Unit
riots
Press UP or DN to select the Speed Unit on the GPS setting interface and it includes knots and km/h and
relative. Select the desired item.

GP:z; Setting G P 3 Setting


Altitude Type Altitude Type
Relative Relative
Speed Unit Speed Unit

(4.3) Date Type


Press UP or DN to select the Date Type on the GPS setting interface and it includes DD-MM-YY, MM-DD-
YY and YY-MM-DD. Select the desired item.
(4.4) Time Zone
Press UP or DN to select the Time Zone , press R or L to set the desired Time Zone.

GP,-; Setting III G P 3 3 e tti n


[)ate TtiBFI N Date Typ P
D D -M -YY D -Nil M -Y.))
Time Zone Time Zone
I_ITC+08:00 11

(4.3) Date Type (4.4) Time Zone

Function Menu can help you custom adjustments for the selected models. The menu includes such items as
Reverse Switch, Travel Adjust, Sub Trim, Dual Rate and Exponential, Throttle Hold, Throttle Curve, Differential,
Balance, Gyro Sensor, Governor,Aileron to Rudder Mix, Elevator to Flap Mix, Rudder to Aileron/Elevator Mix,
Flap System, Aileron to Flap Mix, Program Mix, Monitor,Fail Safe, Sensor view, Trainer and Timer.
3.1 Reverse Switch
Press ENT in main interlace to enter main menu; Press UP or DN to move the navigation mark to Function
Menu. And press ENT to enter Function Menu, Press UP or DN to choose Reverse Switch and Press ENT
to enter into Reverse Switch interface.

Rover ;N Vylitr h Or! Reverse 3%..vitch


E I P V;=1.til r Elev;a.tor
"HU Re verse
Ai I e To n Aileron

Press UP or DN to move navigation mark to ELEV(take Elevator for example), Press R or L to shift the status
between nomal and reverse. These are two status for option. And the default setting is Normal. All Channels
Reverse Switch like: Aileron, Throttle, Rudder, Gear, Flap, Gyro can be referred to the way of ELE Reverse
Switch. And press EXT to exit after finishing setting.

DEVO 7E - 52
Welcome to use the DEVO 7E transmitter
deUention
DEVO 7E

3.2 Travel Adjust


Press ENT to enter into main menu. Press UP or DN to move navigation mark to select item Function menu.
Press ENT to enter Function Menu. Press UP or DN to select Travel Ajust, Press ENT to enter Travel Adjust
interface, as below illustration. It shows the Travel Adjust status of one channel:
Take ELEV for example, Press UP or DN to move navigation
Trz-fyiel Adjust 1E1
to desired item Elevation of U. Press R or L to increase or
decrease the servo travel range. The adjustment range is
El P from 0.0% to 150.0%. The factory default is 100.0%.
LI100.1, Press UP or DN to move navigation mark to desired item
D of ELEv. Press R or L to increase or decrease the servo
D 01-j, travel range. The range is from 0.0% to 150.0%. The factory
default is 100.0%.
All other channel's Travel Adjust like Aileron, Throttle, Rudder, Gear, Flap, Gyro can be referred to ELEV
travel Ajust. Press EXT to exit after setting finished.
3.3 Sub Trim
Sub Trim is used to fine tune the servo neutral position during setup. In order to avoid pushing the servo beyond
it's limits and possibly causing damage it is advised to first mechanically adjust the servo arm/bell crank to be as
close to the neutral point as possible. Only when this is complete may sub trim be used to make a final adjustment

Setup: 3ub Trim


Press ENT to enter Main Menu, Press UP or DN to move EIe'y'ator
the navigation mark to desired item Function menu. Press 0.0
ENT to enter Function menu, Press UP or DN to select
Sub trim, and press ENT to enter Sub Trim interface. Aileron
0.
The interface shows the items and the channels which are adjustable. Press R or L to change the neutral point
of Servos. The default for every channel is 0.0%. The permitted adjustment ranges are show in the table below:

Channel name Adjustment range Channel name Adjustment rang

Gear -62.5% — +62.5%


Flap D62.5% —U62.5%
Throttle Gyro -62.5% — +62.5%
Rudder

Press EXT to exit after adjustment finished.


3.4 Dual rate and Exponential
Dual Rate/Exponential is a function which permits a change in behavior of the control sticks between pre-
defined settings. Dual Rate alters the maximum and minimum servo travel available, Expo has no effect on
the maximum or minimum travel but decreases or increases the sensitivity to stick movement in an exponential
manner. One use of Dual Rate/Expo is to reduce the sensitivity of the controls when landing.
Setting method
Dual Rate and Ex... ED
Press ENT to enter main menu. Press UP or DN to move
navigation mark to desired item Function Menu. Press Channel
ENT to enter Function menu, press UP or DN to choose Elevator
Dual rate and Exponential, Press ENT to enter D/R and
Exponential interface. F'osition
p R
(1) Channel selection
Press UP or DN to move navigation mark of Channel, Press R or L to set up channels containing Elevator,
Aileron and Rudder. Choose the desired channel for setting.

DEVO 7E - 53
clAntion
DEVO 7E
Welcome to use the DEVO 7E transmitter

(2) Position selection


Press UP or DN to move navigation mark to desired item Position. In the
manual mode, the function of Dual rate and Exponential will be executed
by the corresponding FMOD switch among PosO and Pos1. Take the item
Elevator at channel as an example, It's possible to shift between PosO and
Pos 1 via pushing or pulling the FMOD switch.

Du s.I Rate and E. x... 1E1


(3) Dual rate adjustment
Position Press UP or DN to move the navigation mark to desired
Pos 0 item Dual Rate. It's possible to change the dural rate value
Dual Rate of Postion via pressing R or L and the corresponding value
curve in the right top of interface will be changed accordingly.
100% The factory default is 100%.
(4) Exponential
Press UP or DN to select Exponential item of navigation mark. It's possible to change Dual Rate and Exponential
value in Pos when pressing R or L to change the value. There are ± 100% and Line three adjustment. At the
same time, the corresponding curve will be changed and shown at the right graph.
(5) Flight Mode 0
Press DN to move the navigation mark to Flight Mode 0, press R or L to choose PosO and Pos1.

Dual Rate and Ex... IE. Dual Rate and Ex..,


C1 1..i al Rate r r 11 Flight Mode 0 !-
Pas 0
Exporientia.1 Flight Mode
Line Pos 0
(4) Exponential (5) Flight Mode 0

(6) Flight Mode 1:Refer to "(5) Flight Mode 0"


Press EXT to exit after finishing the setting.
3.5 Throttle Hold
If the throttle hold function is activated in the function settings menu, it can be operated by the Throttle Hold
switch as shown in the picture below. The permitted setting range is from -20.0% to 50.0%. The default setting
is inhibited.
Press ENT to enter main menu, Press UP or DN to move navigation mark to select Function menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Hold, Press ENT to enter Throttle Hold
interface, as below illustration:

Th roldle Hold Throttle Hold


Hold Status Hold Status
111111E c
Hold Position
5.0% 11
Press R or L to activate Throttle Hold function, and expansion list will be shown as Throttle hold status, throttle
hold position and Throttle hold switch.
(1) There are two items under Throttle Hold Status: Active and Inhibit. The factory default setting is Inhibit.
(2) Throttle Hold position
In the Throttle Hold interface, press UP or DN to make the Navigation mark choose "Throttle Hold Position"
setting options. Press R or L to change data, the minimum value is -20.0%; the maximum value is +50.0%.

DEVO 7E-54
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(3) Throttle Switch setting


Throttle Hold
It's invalid for setting, the factory default is HOLD switch
which will be shown in the status item. When the Throttle Hold ::::witc: h
Hold switch is ON, data under the Throttle Hold can not be
amended until Throttle Hold switch to be OFF, and the hold 111
status is changed. status
Press EXT to exit after setting up finished.
L

3.6 Throttle Curve


Throttle Curve are adjusted through 7 points.
Setting method:
Press ENT to enter main menu, Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Curve, Press ENT to enter Throttle Curve
interface.The enquiry dropdown is shown "All servos hold?" If click OK, all the servos will be locked at the
current status, if click Cancel, all the servos will be unlocked at the current status.

TI-irottle C:urive Throttle C:urve


Channel 0.0 El .
SPriyEos Throttle
Cancel Position
C
ortmaransmrtessaanmenn.,..:anummannano.......mnmentrns pos L I HU H
J

(1) Channel setting


The default setting is Throttle Channel, and can not reset.
(2) Position selection
Press UP or DN in the "Throttle Curve" setting interface to select "Position", press R or L to select the item
you want to set in the list with Pos 0 and Pos 1.
(3) Exponential Adjustment Throttle C.::1...1ryie
0 .0 0 .0
Press UP or DN in Throttle Curve interface to move Position
navigation mark of exponential curve and press R or L F' 0 s H
to set the exponential function Off and On. The throttle
curve will be changed smoothly if touching ON, or in Exponential
fold line if clicking OFF. Off L I 2m3 H
(4) Curve setting
It includes two items: Point and Output.
(4.1) Point setting
Press UP or DN in Throttle Curve interface to select Points setting. Press L to expand a list including seven
points: "Point-L", "Point-1", "Point-2", "Point-M", "Point-3", "Point-4" and "Point-H". Press R or L to select the
point you want to adjust.

Throttle Curyie Throttle Curve !Lig

F'oint i .0 Point r.0 .0


ql
Point - L Point -
Status is
!. 1 2M3L11.1 !rim I: 2 nu Li fl

(4.2) Status setting


After above setup, press UP or DN to select Status setting, press R or L to set Inhibit and Active. Select Inhibit
if for keeping the current value (the default setting is Inhibit). Select Active for changing the above points'
value.

DEVO 7E-55
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(4.3) Output setting

UP or DN to move navigation
An expansion list of Output items will be shown after activating the Status. Press

mark to select Output item. And press R or L to increase or decrease the amount of selected point with a
minimum of 0.0% and a maximum of 100.0%. The curve graph in right will be change accordingly.

Throttle Curve Throttle Curie


P Dint Status 0.0 0.0
73 1.7.drit - 1 Ad 1 V e

Status 0 UtP Lit


.
J
Active 1 6,5%LIW134H
/ 11

(4.2) Status setting (4.3) Output setting

(4.4) Throttle setting

The switch between Pos 0 and Pos 1 can be freely realized through throttle stick after the below amount

has been set up. The below set amount is the position of throttle stick as well as the switch point.

C.: R
Throttle Stick n Throttle setting: Press UP or DN to select Throttle seting,

Inhibit Press L to decrease the amount with a lower limit of 0.0%


or Inhibit, Press R to increase the amount with an upper
Siyvitch limit of 100.0%.

Pos 0 I.. 21113

(4.5) Switch Selection

When the item Throttle Stick is set in Inhibit, it is possible to switch between Pos 0 and Pos 1 by Switch.

Press UP or DN to select "Switch" . Press ENT to enter into Switch selection interface, press UP or DN to

choose desired item. Press ENT, the desired item whose left side will be changed into "1" from "0". If two or

more items are selected, the item should be chosen, whose left side should be changed into "1" from "0".
Press EXT after finished it.

Throttle Curiyie Switch


ri . ol
Throttle Stick. !3 • 0 :9

Inhibit (75)Flight mode n


3i.hitch IT) Flight r'y'l 0 le
Pos EMI.] N r ;7-1.1
3.7 Differential
If want to use this function, Flaperon or Delta should be previously selected in Wing Type of Model Menu.
Refer to "2.11 Wing Type".

(1) Aileron differential setting

Press ENT to enter into Main menu; press UP or DN to choose Function menu. Press ENT to enter into
Function menu; press UP or DN to choose Differential, press ENT to enter interface of Differential, illustration

as below.

Differential
Channel Mounting servos in left and right ailerons are a must if
Aileron using this function. The following interface will be shown

F' o s 0 after Flaperon or DELTA selected in Wing Type. Refer


to "2.11 Wing Type".

DEVO 7E -56
Welcome to use the DEVO 7E transmitter
deUention
DEVO 7E

(1.1) Channel
Current setting channel is Aileron. System default can not be set.
(1.2) Setting for Pos 0
Press UP or DN to choose Pos 0, press R or L to increase or decrease differential value, respectively. The
adjustable range is ± 100%.
(1.3) Setting for Pos 1
Press UP or DN to choose Pos1, press R or L to increase or decrease differential value, respectively. The
adjustable range is ± 100%.

Differential Differential
C h ;71.nn el F'os 0
Aileron
Pos 0 F'os 1
-0
H
1
;11.111
. U0
(1.2) Setting for Pos 0 (1.3) Setting for Pos 1

(1.4) Switch selection


It is possible to switch by Setting Switch when differential is in use.
Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose
desired item. Press ENT, the desired item whose left side will be changed into "1" from "0". If two or more
items are selected, the item should be chosen, whose left side should be changed into "1" from "0". Press
EXT after finished it.

Differentia.1 Svyiitch
F' o s
(75:1F g ht Mode 0
iyv Ito I-1 135)Flight Nelode
P ip s 0 iTAFI p o r 8.1
(2) Rudder differential setting
V-Tail should be previously set in Wing Type of Model Menu if the rudder differential function is activated.
Refer to "2.11 Wing Type". And then the following interface will be shown:

DlfferentiEd
Channel
(2.1) Setting for Pos 0
Rudder Press UP or DN to choose Pos 0, press R or L to increase
Fos 0 or decrease differential value, respectively. The adjustable
range is ± 100%.

(2.2) Setting for Pos 1


Press UP or DN to choose Pos1, press R or L to increase or decrease differential value, respectively. The
adjustable range is ± 100%.
(2.3) Switch selection
It is possible to switch by Setting Switch when differential is in use.
Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose
desired item. Press ENT, the desired item whose left side will be changed into "1" from "0". If two or more
items are selected, the item And should be chosen, whose left sice should be changed into "1" from "0". Press
EXT after finished it.

DEVO 7E-57
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

Differential
Pos 1
IT: Flight Mode 0
IT)Flight Mode 1
PO,; 0 1:15:IF N r mal
(3) Flap differential setting
It should be previously set the flap dual channel function in Wing Type of Model Menu (refer to "2.11 Wing
Type") in order to activate the menu of Flap Differential.
(3.1) Setting for Pos 0 Differential
Press UP or DN to choose Pos 0, press R or L to increase Channel
or decrease differential value, respectively. The adjustable
range is ± 100%. Flap
(3.2) Setting for Pos 1
Press UP or DN to choose Pos1, press R or L to increase
or decrease differential value, respectively. The adjustable
range is ± 100%.
(3.3) Switch selection
It is possible to switch by Setting Switch when differential is in use.
Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose
desired item. Press ENT, the desired item whose left side will be changed into "1" from "0". If two or more
items are selected, the item should be chosen, whose left side should be changed into "1" from "0". Press
EXT after finished it.

Differential Siyvitch
Pos 1 And
IT:Flight N./lode u
vyiitch 1:15)Flight l'yloda
Pos U r.1.1Flari Normal

3.8 Balance
This function can adjust the parameters of the two servos which are used in the dual channels. It should be
previously activated one of these wing types of Flaperon, Delta, and V Tail in Wing Type at Model Menu.
Refer to "2.11 Wing Type".
Setting method:
C
Press ENT to enter into Main Menu, press UP or DN to C: h nB
choose Function. Press ENT to enter into Function menu,
press UP or DN to choose Balance. Press ENT to enter Aileron
interface of Balance setting, picture as right:

(1) Channel: current setting channel is Aileron. System default can not be set.

(2) Point parameter adjustment Elalance


Point< Right Setting: Press UP or DN to choose "Point<
Right". If need to adjust the value, press L (0% means no Po i Fit .:::: A
adjusting). A minus value means the amending direction is
downward; press R to adjust value(0% means no adjusting). lr
A plus value means the amending direction is upward. The
adjustable range is ± 100%.
0%

DEVO 7E - 58
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

Point-Right Setting: Press UP or DN to choose "Point-Right". Press R or L to inhibit or active. If need to adjust
please active it. There will be expanded value adjustment item. Press UP or DN to choose "0%" If need to
adjust the value, press L (0% means no adjusting). A minus value means the amending direction is downward;
press R to adjust value (0% means no adjusting). A plus value means the amending direction is upward.
The adjustable range is 100%.

Balance Balance
Point - Point - Hight
Inhibit
oc):, ;
Press UP or DN, there will be setting for Point-1, Point-2, Point-3, Point-Left, Point>Left, refer to the setting
method as above. Press EXT after finished it.
3.9 Gyro sensor
This function offers the gain adjustment for gyro sensor, which can be manually set through HOLD switches
or Flight mode switch, and also is possible to be automatically switched among various gains through flight
mode switch. (The flight mode should be activated. Refer to "2.9 Device Select").

Setup: Gyro SPM=;or 1E1


Press ENT to enter Main menu; Press UP or DN to choose I Ii B
Function menu. Press ENT to enter Function menu; Press
UP or DN to choose Gyro sensor, then press ENT to Gyro Manual
Sensor interface. h a.n A PI
(1) Manual Setting U
(1.1) Manual Setup: In the Gyro Sensor interface, here are Manual set and Automatic set for selectable choice.
Press R or L to select Manual option. ( Automatic setting can be activated if Flight mode is act, refer to "2.9
Device selection" ) . Choose "Manual Setup"
(1.2) Channel: The factory default channel is AUX 2. the Output set offer the function to change other control
channels (refer to "2.10 Output").
(1.3) Switch Select: In the interface of Gyro Sensor, press UP or DN to choose SWITCH, there are FMODSW
and HOLDSW for selectable sets, press R or L to choose the desired switch for Manual control.
(1.4) Sensitivity Setup: If the switch selection is two level, there are Position 0 and Position 1 two selection
which can set the sensitivity individually.
(1.4.1) Status:turn the setting gyro control switch, the status G s1.0 e:;or
items will display the current switch status position.
(1.4.2) Pos 0:Press UP or DN to move the navigational mark C: I
to Pos 0 and press R or L to increase or decrease, respectively, H 0 LD Vy°
the value.If the gyro used has two modes of NOR and AVCS,
NOR will be activated when the value is less than 50.0%. 3 at t S
In NOR mode, the smaller the value is, the bigger the gyro
sensor gain will be. The factory setting is 50.0%.
(1.4.3) "Pos 1" is the same setting way as above "Pos 0".

(2) Automatic setting


Gyro Sensor (2.1) Automatic Setup: in the Gyro Sensor interface,press
Mode 1
II UP or DN to choose Mode, there are Manual set and
Automatic Automatic set for selectable choice. Press R or L to select
Automatic option.
Channel (2.2) Channel: The factory default channel is AUX2, the
u:0_I Output set offer the function to change other control channels
(Refer to "2.10 Output").
(2.3) Switch:The switch function isn't available under Automatic setting.

DEVO 7E - 59
cleUention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(2.4) Status:turn the Flight Mode switch,the status display current flight mode position.There are "Flight Mode
0", "Flight Mode 1" etc.
(2.5) Flight Mode 0: Press UP or DN to select Flight Mode I!.
G ...iro Sens or
0, press R/L can increase or decrease the value individually. Sta.tu!E;
If the gyro used has two modes of NOR and AVCS, NOR
will be activated when the value is less than 50.0%. In NOR
Flight Mode 0
mode, the smaller the value is, the bigger the gyro sensor tylode 0
gain will be. The factory setting is 50.0%.
50.0
(2.6) Flight Mode 1 setting refer to "Flight Mode 0".After finishing the set, press EXT to exit.
3.10 Governor
To setup Governor, the Governor needs to be active under the Device Output menu (Refer to section 2.10
Device Output). The Govemor function is a feature which, when enabled, automatically tries to maintain a
constant main rotor speed.
It is possible to setup different Governor settings for each flight mode. On the transmitter, the display is a
percentage for reference/adjustment, the actual rotation speed is set by the governor.

Setup:
Press ENT to Main menu in the interface, use UP or DN to
Governor.
choose function menu. Press ENT to function menu. Use Status
UP or DN to choose Governor, then press ENT to the Governor
setting interface, there are status and channels. Press UP
or DN to "Flight Mode 0", "Flight Mode 1", and so on. Chan n P

(1)Status
Toggle the Flight Mode, the status set display present flight mode position. There are "Flight Mode 0", "Flight
Mode 1" and so on.
(2)Channel: The setted channels will display in "2.10 Device output" (Setup refer to 2.10 Device Output)
(3) Flight Mode 0
Press "UP/DN" to make the navigation choose the "Flight
Governor
Mode 0"set, press R/L to increase/decrease the value.The Flight Mode
factory default value is 0%.,adjustable range ± 125%. 0%
(4)"Flight Mode 1" setting refer to "Flight Mode 0".
After finished, press EXT to exit.

3.11 Aileron to Rudder Mix


This function is possible to execute the mix of aileron to rudder, which is controlled by switch.
Setting method:
Press ENT enter to Main menu, press UP or DN to select Function menu. Press ENT enter to Function menu.
Press UP or DN select Aileron to rudder mix,press ENT to enter into Aileron to Rudder mix setting interface.

Aileron to Rudder... CI (1) Pos 0 Setting leftward setup


Pos. 0 Left Press UP or DN select leftward mix value, press R or L,
09; leftward mix value of aileron to rudder will be changed.
The mix direction will be revised by changing the sign of
Pips 0 Right plus or minus before the value. The adjustable range is
±125%.

(2) Pos 0 Setting rightward setup


Press UP or DN to select rightward mix value, press R or L rightward mix value of aileron to rudder will be
changed. The mix direction will be revised by changing the sign of plus or minus before the value. The
adjustable range is ±125%.

DEVO 7E - 60
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(3) Pos 1 setup, the setup is same as above.


(4) Throttle stick setup
The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle stick. Press UP or
DN of Throttle Stick to set the position amount of throttle stick. The default setting is Inhibit. The adjustable
range is 0.0-100.0%.
(5)Switch setup
The switch will display the current switch position. press UP or DN to select the desired item press ENT to
the setting interface and "0" before the item will be changed into "1". If two or more items are selected, the
item And should be selected. Press EXT to exit after finished.

Aileron to Rudder._
Throttle Stick
inhibit 1:T5)FI i9 ht Mode 0
ii iFIiqht Mode 1
Fos 0 0.1 F I a. p N o rm

3.12 Elevator to flap mix


This function is used to execute the mix of elevator to flap.
Press ENT enter to main menu, press UP or DN to select function menu. Press ENT to enter to function menu.
Press UP or DN to select Elevator to flap mix, press ENT to enter to Elevator to flap mix setting interface.

Elev;=1.tor to Flap (1) Pos 0 UP setup


Pos 0 Up Press UP or DN to move the navigational mark to select
OCV
,e O item Pos 0 UP, press R or L upward mix value of Elevator
to flap mix will be changed. The mix direction will be
F'os 0 0n Wn revised by changing the sign of plus or minus before the
0% value. The adjustable range is ±125%.

(2) Pos 0 Down setup


Press UP or DN to move the navigational mark to select item Pos 0 Down, press R or L downward mix value
of Elevator to flap mix will be changed. The mix direction will be revised by changing the sign of plus or minus
before the value. The adjustable range is ±125%.
(3) Pos 1 setup, the setup is same as above.
(4) Throttle stick setup
The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle stick. Press UP or
DN of Throttle Stick to set the position amount of throttle stick. The default setting is Inhibit. The adjustable
range is 0.0-100.0%.
(5)Switch setup
The switch will display the current switch position. Press UP or DN to select the desired item, press ENT to
the setting interface and "0" before the item will be changed into "1". If two or more items are selected, the
item And should be selected. Press EXT to exit after finished.

Elevator to Flap ... Syyitch


Throttle Stick.
Inhibit (T) Fl i 9 ht ode0
Syyttch .10. ICJ Fli9ht le
Pos 0 (75.1FI 8.ri NI 0 rm E1.1

DEVO 7E — 61
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

3.13 Rudder to aileron/elevator mix


This function is used to execute the mix of rudder to aileron/elevator. It will help eliminate waver or shake
caused by rudder stick operation.
Setup: Rudder tn Ailercirk
Press ENT to enter Main Menu in the main interface,and Elevato r Po :7-; 0 Le<t
press UP or DN to make the navigation mark to choose
"Function Menu". Press ENT to enter "Function Menu", then 0%
press UP or DN to choose "Rudder to aileron/elevator mix" Pos U Right
and press ENT to enter "Rudder to aileron/elevator mix"
setting interface.
(1) Elevator setup
(1.1) Elevator Pos 0 Leftward Setup
Press UP or DN to make the navigation mark choose "Elevator Pos 0 Leftward setting" item, and press R or
L to change the value and the Elevator mix amount when operating Rudder leftward. The mix direction will
be revised by changing the sign of plus or minus before the value. The adjustable range is ±125%.
(1.2) Elevator Pos 0 Rightward Setup
Press UP or DN to make the navigation mark choose "Elevator Pos 0 Rightward setting" item, and press R
or L to change the value and the Elevator mix amount when operating Rudder rightward. The mix direction
will be revised by changing the sign of plus or minus before the value.The adjustable range is ±125%.
(1.3) Elevator Pos 1 Setup:refer to "1.1 Elevator Pos 0" Setup.

(2) Aileron Setup


(2.1) Pos 0 Setup: refer to "1.1 Elevator Pos 0" Setup.
(2.2) Pos 1 Setup: refer to "1.1 Elevator Pos 0" Setup.
(3) Throttle stick setup
The switch between Pos 0 and Pos 1 can be realized by the position of Throttle Stick,then press R or L to
change the value or Inhibit. Change the value to set the Thottle Stick position. The default setting is "Inhibit",
the adjustable range is from 0.0 to 100.0%.
(4) Switch Setup
Switch item will display the current Switch position.Press UP or DN to make the navigation mark choose
"Switch" item, and ENT to enter the selectable switch interface, press UP or DN to make the navigation mark
choose the desired Switch. Press ENT to confirm and change the left sign from "0" into "1". If two or more
items are selected, the item And should be selected and then the left sign "0" will be changed into "1". Press
EXT to exit after finished.

R 1=! r to Ai leron... h
Th e Sti
Inhib it (0) r ght mode 0
h (15:1 Fl i 9 h t NA 0 d e
Pos 0 (5)Flap Normal
3.14 Flap System
This function can modify some effects on elevator.lt is possible to set 2 status of elevator through 2-way flap
control switch.

Setup:press ENT to enter Main Menu in the main interface, Flap stem
then press UP or DN to make the navigation mark choose 0: N o rm al
"Function Menu", press ENT to enter Function Menu. Press
UP or DN to choose "Flap System" and then ENT to enter
its setting interface. 1: Ldnd
(1) Elevator Setup
There are 2 options: 0:Normal and 1:Land.

DEVO 7E-62
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(1.1) Elevator 0:Normal position


press UP or DN to make the navigation mark choose "Elevator 0:Normal", and press R or L to change the
elevator mix amount. It is possible to change the direction by altering U or D before the amount. The default
setting is 0%, and the adjustable range is U125% - D125%.
(1.2) Land position: Please refer to "1.1 Elevator 0:Normal" setting
(2)Status
Press UP or DN to make the navigation mark choose "Status", then vibrating the flap switch(refer to 2.9 Device
select) will display current position
(3)Auto land
(3.1) Throttle stick Setup
Press UP or DN to make the navigation mark choose"Throttle stick"item,and press R or L to change value
or Inhibit. It is possible to set the position when changing the value.The default setting is "Inhibit", and adjustable
range is from 0.0 to 100.0%.

L
Fla..p System Flap. 3s,istem
Status Throttle Stic:k.
0: Normal
Throttle Stick.
Inhibit
i] Flight lode
50, 0%

h
(3.2) Flight mode 0 Setup
It is possible to set a certain flight mode switch automaticly after automatic land.When do this, you must come
to "Wing type" setting interface under the Model Menu and make correspond Wing type Setup. Refer to 2.11
Wing type.
Press UP or DN to make the navigation mark choose "Flight
Flap Siyistem
mode 0" item, and press R or L to 3 options :Switch, 0:Normal Flight Mode
and 1:Land. It is Mannul control when choose "Switch", but
Automatic control when choose Flight mode switch position.
Switch
(3.3) Flight mode 1 Setup: refer to "(3.2)Flight mode 0 Setup"
Flight Mode 1
Press EXT to exit after finished. 3\vitch
3.15 Aileron to flap mix
The function aims at mixing flap when operating aileron stick, and can set switch. The flap dual channels
should also be previously activated at Wing Type in Mode Menu(refer to"2.11 Wing Type")

Setup: Aileron to Flap ....


Press"ENT" to enter into"main menu"; press UP or DN to Pos CI Left
make navigation mark select "function menu", press "ENT" ;1'
to enter into "function menu"; press UP or DN to select Oo"
/0 1.11
"Aileron to flap mix", press"ENT" to "Aileron to flap mix" Pos [I Right
designed interface.
(1) Pos 0 to leftward Setup
Press UP or DN to make navigation mark select "Pos 0 to leftward setting", press R or L to change the leftward
mix value of aileron to flap, the mix direction will be revised by changing the sign of plus or minus before the
value, the adjustable range is ±125%.
(2) Pos 0 to rightward Setup
press UP or DN to make navigation mark select "Pos 0 to rightward Setup", press R or L to change the
rightward mix value of ailren to flap, the mix direction will be revised by changing the sign of plus or minus
before the value, the adjustable range is ±125%.
(3) Pos 0 to leftward Setup: refer above "(1) pos 0 to left Setup"
(4)Pos 0 to rightward Setup: refer above "(2) pos 0 to right Setup"

DEVO 7E - 63
cleention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(5) Throttle stick Setup


The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle stick. Press UP or
DN to make navigation mark select "throttle stick setting", press R or L to change the value or inhabit. Change
value can set throttle stick postion. The default setting is "inhabit". The adjustable range is from 0.0% to 100.0%
(6) Switch Setup
Press UP or DN to make navigation mark select "switch" setting, press ENT to enter into usable switch interface,
press UP or DN to make navigation mark select desired switch setting.Press ENT to confirm,make left sign
from "0" to "1". If two or more items are selectable,the item And should be selected, to make left sign from
"0" to "1", Press EXT to exit after finished.

Aileron to Flap Mix 1E1 iyvitc h


Throttle Stick.
Inhibit 1:75)F1 i 9 ht Mode 11
itl h IT) F I i 91-it o d e 1
111111111=11111 (75) F 3. NI rm al
3.16 Program mix
There are total eight sets of Program Mix, It is possible to freely set th channels and amounts which you
want to select and amend,respectively.
Setting method: Program Mix
press "ENT" enter to "main menu"; press UP or DN to make
navigation mark select "function menu", press "ENT" to enter Program Mix 1
into "function menu"; press UP or DN to select "program
mix", press"ENT" enter into"program mix", shown "program
Inhibit
mix 1" and settable status(the factory default setting is No rill &.*1.1
Inhibit). Take program Mix 1 as an example.
C urve
(1) Setting method for Normal in Program Mix.
Press UP or DN to make the navigation mark choose "Normal" item,and press ENT then expands up an
enquery "All Servos Hold?".Choose "OK" for all the servos will be locked at the current statuses;choose
"Cancel" for unlocked. Enter the next interface after choosing.

Program I'v1ix 1 Program Mix 1 EL!


Master
Al I :72.171 re' os Hold '? II Elevator
K p I a VI:l
EI

(1.1) Master Channel Setup


Press UP or DN to make the navigation mark choose "Master Channel" item, and press ENT to enter the
Master Channel setting interface.Press UP or DN to choose the desired channel, then press ENT to confirm
the mark "J" before choosed channel name, press ENT to return the Program Mix 1 interface.
(1.2) Slave Channel Setup
Press UP or DN to make the navigation mark choose "Slave Channel " item, and press ENT to enter the Slave
Channel setting interface.Press UP or DN to choose the desired channel, and press ENT to confirm the mark
"4" before the Slave Channel, and "EXT" to return Program Mix 1 interface.

ti aster Slave uai

veElevator
Aileron Aileron I
Throttle Throttle
Rudder Rudder
(1.1) Master Channel Setup (1.2) Slave Channel Setup

DEVO 7E - 64
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(1.3) Gain setting:take Elevator at Master Channel as an example.


(1.3.1) Position 0 upward
Mix amount setting when elevator stick moved upward.Press
P ro g ram M ,:; 1
UP or DN to make the navigation mark choose "position 0 F' 0 s p
upward"item,and press R or L can increase\decrease Mix
amount.lt is possible to reverse mix direction through
changing the plus or minus sign before amount.The
adjustable range is ±125%.
(1.3.2) Position 0 downward
Mix amount setting when elevator stick moved downward. Press UP or DN to make the navigation mark
choose "position 0 downward" item, and press R or L can increase \decrease Mix amount.lt is possible to
reverse mix direction through changing the plus or minus sign before amount.The adjustable range is ±125%
(1.3.3) Position one upward/downward setting method refer to (1.3.1) position zero upward setting .
(1.3.4) Offset Setup
This function can make Slave begin to mix through the ro g rain Mix 1
corresponding Lever switch from a certain point as the starting Offs et
point. Press UP or DN to make the navigation mark choose
"Offser',press R\L to increase or decrease the mix amount.lt is
possible to reverse the offset direction through changing the plus Throttle Stick.
or minus sign before amount. The adjustable range is ±100%. ;
ill 1...! I.
(1.4) Throtte Stick
Press "UP" or "DN" to select "throttle stick setting".Press "R"or "L" to change the data for setting its position
amunt or Inhibit. The default setting is Inhibit. The adjustable range is 0.0-100.0%.

Program Mi>:: 1 F'rogram NA


i 1
Offset Throttle
Or.:%; Roz
Throttle t-1
Inhibit F' 0 s

(1.5) Switch Selection


Press UP or DN to make navigation mark select "switch" setting, prss ENT enter into useable switch interface,
press UP or DN to make navigation mark select desired switch setting.Press ENT to confirm,make left sign
from "0" to "1". If two or more items are selectable,the item And should be selected, to make left sign from
"0" to "1", Press EXT to exit after finished.

Program N ii::; 1 ri
ThrottlID C
ht od e
_~ Witl= h 05)Flight Mode
P o s 0 11 @Flap No rrn al
(2) Setting Method for Curve in Program Mixl
Press the item Curve in Program Mix 1 and expands an enquiry All Servos Hold?" Click OK for all the servos
will be locked at the current states; click Cancel for unlocked. Enter the next interface after clicking. Press ENT
key to enter the setting interface of Program Mix1. The interface will show the setting items and curve table.

F' ro g r am NA i 1 F'ro y ram i 1


Nil a ste r
All 517..!rly'os Hold Elevator
an e
L
'=====.2=nx.mauxesustms=me:=3
e %,;:kt 0 r. L I 21113 Fl

DEVO 7E - 65
cle(Lnlion
DEVO 7E
Welcome to use the DEVO 7E transmitter

(2.1) Master Channel Setup


Press UP or DN to move the navigation mark to "Master Channel"item, and press ENT to enter the Master
Channel setting interface. Press UP or DN to choose the desired channel, then press ENT to confirm the
mark ".4" before choosed channel name, press ENT to return the Program Mix 1 interface.
(2.2) Slave Channel Setup
Press UP or DN to move the navigation mark to "Slave Channel "item, and press ENT to enter the Slave
Channel setting interface. Press UP or DN to choose the desired channel, and press ENT to confirm the mark
"4" before the Slave Channel, and "EXT" to retum Program Mix 1 interface.

Elevator
Ail P ron Aileron
ThrottiR Throftli9
Rudd Pr Rudder
(2.1) Master Channel Setup (2.2) Slave Channel Setup
(2.3) Position
There have two options:Pos 0 and Pos 1.Press
Program Mix 1 IIII

"UP" or "DN"to select the desired position. Slave


(2.4) Exponential Elevator
Press"UP"or "DN"to enter "Exponential", and Press"R"
or "L" to expand a dropdown menu with two options of
Position
Off and On. The pitch curve will be smoothly changed Pos 0 L 121113 4 H
if choosing On. Otherwise choosing Off.
(2.3) Position
(2.5) Point Setup
Press UP or DN to move the navigation mark of Point option. Press R or L, there are 7 piont options including
Point-L, Point-1, Point-2 Point-M, Point-3, Point -4 and Point-H. Select the point you want to set.
(2.6) Status Setup
(There is no Status options when the piont is Point-L or Point-H). After selecting the point that you want to
set, press UP or DN to move the navigational mark to Status item. Press R or L, there are two options of
Inhibit and Active. Select Inhibit for unchanging the current amount (the default setting is Inhibit).

F'r i I 9 ram tvl ix 1 it Pro 9 rain NAix 1


Exponentia.1 !El Status i1 0

Off Active
Point ID Li t P ut I
i
Point - L L 1 21113 H L I2Fi1g4H II
(2.5) Point Setup (2.6) Status Setup
(2.7) Output
When the Status option is Active, the Output option will be listed.Press UP or DN to move the navigational
mark to Output. Press R or L to increase or decrease, respectively, the output amount. It is possible to reverse
the mix direction by changing the plus or minus sign before the amount. The adjustable range is ±100%.

`F'ro gram Mix 1


(2.8) Throttle Stick Setup o 13
Throttle Stick.
Press "UP" or "DN" to select "throttle stick setting". Press
"R"or "L" to change the data for setting its position amunt Inhibit
f
or Inhibit. The default setting is Inhibit. The adjustable Siyiyiitch E
range is 0.0-100.0%.
p0 II L 121113 4 H

DEVO 7E - 66
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

(2.9) Switch Selection


Press UP or DN to make navigation mark select "switch" setting, prss ENT enter into useable switch interface,
press UP or DN to make navigation mark select desired switch setting.Press ENT to confirm,make left sign
from "0" to "1". If two or more items are selectable,the item And should be selected,to make left sign from "0"
to "1", Press EXT to exit after finished.

P ro g ['aro i 1 :1; t c: h IDA


Th rottl e c a
r And
Inhibit (15)Fli g ht N,, ode u
S wrtc h 1:751 Flight o d e
P os _ L 12f113 4 H Fl ap r'11lrrlla.l
Press "EXT" to return to the interface of Program Mix for other setting. Or Press "EXT" once again to exit.
3.17 Monitor
The monitor function allows the pilot to monitor the outputs of each transmitter channel.

Press ENT to Main Menu, and use UP or DN to select Function Monitor


Menu.Press ENT to enter the Function Menu and then use
UP or DN to select Monitor and press ENT to enter the monitor
interface for checking the current working status of each
I I • I I .
channel(See rightside View). Press EXT to exit .
I I
I I ' I I
3.18 Fail safe
Two options exist if the receiver loses the connection with the transmitter; the first is HOLD - keep the last
action data received, the second is to use a pre-set failsafe value. The default setting is Servo Hold.
Setup: Fai I Safe
Press ENT to Main Menu, use UP or DN to select Function
Menu. Press ENT to Function Menu then use UP or DN to Elevalo r
select Fail Safe and press ENT to enter the Fail Safe
interface.Take the item Elevator as an example to explain. SPryo H n Id
Use UP or DN to select Elevator on the Fail Safe interface,
then press R or L to change the status of Servo Hold into
Fail Safe(If you want to keep Servo hold status, there is no need to re-set). There is a expanded sub-item
below. Press UP or DN to select 0%, then press R or L to increase or decrease the value, respectively, the
position amount which centers on the neutral point of servo. The available value is 125%,respectively. 0% is
the neutral point of servo.
The setting methods for other channels are same as above.
Fail Safe
Press EXT to exit after finished.
E I e',,at o r NOTE: If the helicopter enters a failsafe mode for any
reason power should be disconnected from the Heli and
Fail Safe it must be thoroughly checked over before flying again.
Using 100% throttle after a failsafe event may be dangerous
and cause injury or damage.

3.19 Sensor View


The function can be performed by Activate the Sensor Status in the Model Menu, and it is a must that the
receiver also has telemetry function.
Sensor View Setup: Press ENT to enter the Main Menu and use UP or DN to select the Function Menu. Press
ENT to Function Menu. Use UP or DN to select Sensor View, then press ENT to enter the Sensor View
interface. See below views. If all the sensors disconnect, there will be inhibits shown on the view, means the
telemetry signal lost. If all work normal, all the measured data will be shown.

DEVO 7E-67
deVention
DEVO 7E
Welcome to use the DEVO 7E transmitter

(1) Voltage:Provide 3 diffferent measured voltage values;

Voltage am Volta.g e
Inhibit 5.3 Unit
Inhibit 8,3 Unit
Inhibit a o ri it
(2) Temperature:Press UP or DN to Temperature, which provides 4 different measured temperature values;

Temperature Te m rature
L
Inhibit '2 1 p
°C:
Inhibit '21 °C::
Inhibit ore,
Inhibit D
(3) Rate Sensor:Press UP or DN to Rate Sensor, which provide 2 different measured RPM values;

Rate :--2,ensor CIE Rate Sensor


Inhibit 5 000 FIP NA
Inhibit 4 000 A P
0
(4) GPS Sensor:Press UP or DN to turn to GPS Sensor, show located date, time, longitude, latitude, altitude
and speed;

GF'3 Sensor
Inhibit
Inhibit
Inhibit
Inhibit
3.20 Trainer
To help the beginner pilot it is possible to make two DEVO 7E transmitters operate together using a training
function. The training function permits the teacher to limit or override the controls of the trainee. The instructions
for using the training function are below:
(1) Data copy
The first step is to copy the model settings from the teacher's DEVO 7E to the trainee's DEVO 7E, this guarantees
that the model data in both transmitters is identical. To do this refer to the copy method as described in Helicopter
setup section "2.4 model wireless copy". Once completed, follow the steps below:

( 2) Connection
5":2 thi
Insert the signal wire (supplied) into the DSC socket of the
trainee's transmitter.Turn on the trainee's transmitter and the Nl i:DC1 1
display will alternate between showing PC (data connection
Connection icon at
mode) and the model name (MOD), see image (right)from
trainee's DEVO 7E
the trainer's transmitter into the DSC socket of the trainee's
transmitter. Turn on the transmitter and a linkage icon will be it
shown on the boot screen.

DEVO 7E-68
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E

Linkage Display
Next, tum on the Trainer's DEVO 7E. Select the newly copied model data using the MODEL Menu. Bind to
the aircraft and make a small test flight to confirm the aircraft is operating normally. Tum off the power andinsert
the digital signal wire into the trainer's DEVO 7E DSC port. Tuming back on the power will automatically put
the DEVO 7E into training mode.

I~r An ion
r in Trainee is off and trainer is working
ry 7"-+:7,-
I II I Trainee is working and trainer is off
"7.5.
I 1 •
1.1
Trainer icon
Training Status Display: when the trainer's icon turns to "X", the trainee stops flying and the trainer is working;
when the trainer's icon turns to"V", the trainee is flying and the trainer is in leisure.
(3) Usage
The default setting of the training switch is "R+" key.
During flight, if the trainer press" R+"key,the linkage icon will
be shown as "-Ni" that means the control right is moved to the
trainee from trainer. If trainer pushes "R+" key once again,
the linkage icon will be show as "X" that means the trainer
takes back the control right from the trainee.
(4)Setting for training function channels
Trainee is available to get full or part of flight control power to the aircraft model via setting the training function
channel in the trainer's radio. Below is the Setup:
Press the ENT to Main Menu, use UP or DN to Function Menu. Use UP or DN to select Trainer and press
ENT to enter Trainer interface. The available channels are shown between Elevator, Aileron, Throttle, Rudder,
Gear, Pitch and Gyro, and the current status of trainer switch is also shown there.

Trainer Channel selection:

Eleiyiator. Press UP or DN to select the channel option; press R or L


to select the channel(s) which you want to grant to trainee.
1111EMIM The channels(s) you have selected will be activated as
"Active". The channel(s) which are not granted to trainee
Aileron will be kept inhibited. The default setting is "Inhibit".
E ibit Press EXT to exit.

3.17 Timer
There are two timers on the DEVO 7E, stopwatch and countdown
timer. These timers are activated by switch or by shorcut. Timer
Setup: Type
Press ENT to Main Menu, use UP or DN to Function Menu.
Press ENT to enter Function Menu. Use UP or DN to choose
Stopwatch
Timer, and press ENT to enter Timer setting interface. The
factory default is Stopwatch, and the timing range of stopwatch
is from 0 to 60.

DEVO 7E- 69
deVention
DEVO 7E Welcome to use the DEVO 7E transmitter

(1) Countdown setting


Timer
Press R or L to select Countdown. There is an expand sub-
menu Set Time. Press UP or DN to Set Time interface, use Type
R or L to set up countdown time. The timing rang is from Countdown
00:10-to 60.
Set Time
10:00
(2) Switch selection
Press UP or DN to move the navigational mark to Switch.There are Inhibit and available switch options, use
L or R to choose switches between FMOD SW,HOLD SW,SPSO SW, SPS1 SW, SPS2 SW and SPS3 SW.
Select the desired item except these items of SPSO SW, SPS1 SW, SPS2, and SPS3 which should be
previously set at Stick Position Switch at Model Menu(refer to "2.8 Stick Position Switch").
Press EXT after finished.

(3) Usage of timer


Use the UP key to start and stop the timer. Use DN to reset the timer.You can also set switches to control
the timer. Below is the picture of timer display on the boot screen .

-IIen
1!"-.1 .
1

tri
Timer
L

Software can be upgraded in PC via downloading or uploading the configuration files.


Enter upgrading interface: Press EXT and power on the radio when the radio is in powered off status, below
illustration will show as below.

The operation guide for connecting to PC upgrading should be mentioned with upgrading software.

5.0 Hot keys usage


We offer two hot keys R+, L- for this Radio. With them, you can enter into the gyro sensor and throttle curve
setting interface quickly.
Method:Press R+ once on the main interface to enter into the gyro sensor setting interface. Press L- once,
you can enter into the throttle curve setting interface.

This symbol indicating separate collection for electrical


and electronic equipment.

DEVO 7E-70
\v walkera
Add.: Taishi Industrial Park, Dongchong Town
Panyu District, 511475 Guangzhou
Tel.: ( 8620) 8491 5115 8491 5116
Fax.: ( 8620) 8491 5117
Web: www.walkera.com
The specifications of the R/C Product
Email: [email protected]
may be altered without notice.
[email protected]

You might also like