Fiber Glass Ladder Assembly Instruction
Fiber Glass Ladder Assembly Instruction
Fiber Glass Ladder Assembly Instruction
The ASCEND "ULTIMA TOWER" gives an excep�onally versa�le tower for working in normal applica�ons all frames can be used as upper or
lower sec�ons ,simply place the pla�orm on the third rung from the top of the tower and correct guardrail height is achieved. The number of
trapdoor pla�orm in the tower kit is sufficient to assemble and dismantle the tower using 3T method .
WORKING HEIGHT 3.2 3.7 4.2 4.8 5.3 5.8 6.3 6.8 7.3 7.8 8.3 8.8 9.3 9.8 10.3
MOVING A TOWER :
PLATFORM HEIGHT 1.2 1.7 2.2 2.8 3.3 3.8 4.3 4.8 5.3 5.8 6.3 6.8 7.3 7.8 8.3
MAINTENANCE RULES
Please check that spigot are in to the position and should �it
Grease all moving parts with commercial oil. Wipe off excess oil.
(Fig 3)
6. Before each use check that the MAT is vertical or need readjustment.
450CM LONG STABLIZER 7.70 4 4 4 4 4
3. Raise the stabilizer feet only enough (25mm) to clear the Obstructions.
600CM LONG STABLIZER 10.28 4
Fig 1
TOWER WEIGHT IN KGS 90.08 98.92 125.16 151.74 170.14 178.98 187.7 214.28 232.68 251.76 260.48 287.06 305.46 314.3 328.68
SIZE: WIDTH 135 CM LENGTH 208CM
UNIT
COMPONENTS
WEIGHT
WHEEL 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
5.78
USE OF STABILIZERS
ADJUSTABLE LEG 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
2 RUNG LADDER FRAME 7.86 1 1 1 1 1 1 1 1
stabilizer and place the outside two parallel with the wall.
approximately equidistant from each other, as shown in Fig
speed should not be exceeded during relocation. The ground over which a tower is moved should be capable of supporting
1. If you must move a tower, remove all materials and personnel. When moving a scaffold tower, force must always be moved
the weight of the structure. Make sure tower height is not above 4 mtr while moving the tower. Recheck the tower level and
from the base. The tower should only be moved manually on �irm, level ground which is free from obstacles. Normal walking
Tel
GENERAL SAFETY RULES
1. A risk assessment has been done and safety equipment (Rope etc) and auxiliary tools are 18. Do not work from ladders or stairways, they are a means of access only.
available on site for erec�on and dismantling the tower.
19. Always li� components from inside the tower.
2. The ground condi�on will take the working load as specified .
20. When li�ing materials or components always use reliable li�ing materials to ensure there
3. The loca�on of tower should be checked to prevent hazards during erec�on & is no possibility of it falling.
dismantling, moving and while working on the tower. Level and slope, obstruc�on and
21. Always �e the tower when it is le� una�ended .
wind condi�on should be checked.
22. Guardrails and toe boards must be fi�ed to the working pla�orms.
4. Minimum 2,3 persons are required to safely erect and dismantle the tower.
Website : www.ascenduae.com
guardrail at each pla�orm levels, never stand on an unguarded pla�orm.
Email : [email protected]
6. Do not use any scaffold tower which is damaged, which has not been properly erected,
which is not firm and stable, and which has any missing or damaged parts. 25. DO NOT exceed the safe working load of the pla�orm or structure by accumula�ng debris,
7. Do not erect a scaffold tower on unstable ground, slopes or objects such as loose bricks, material tools on pla�orms as these can be a significant addi�onal load.
boxes or blocks. Only a sound rigid foo�ng must be used. 26. The tower should always be accessed from the inside using the ladder frame ,never climb
8. Ensure that the scaffold tower is always level and the adjustable legs are engaged. Check up from outside. Ensure that the locking hooks on the pla�orm are func�oning correctly.
that you have taken all necessary precau�ons to prevent the tower being moved, or 27. Beware of horizontal forces (e.g. when using power tools), which could generate
rolling away. Always apply all castor brakes or use base plates. instability or overturning of the tower. Maximum horizontal force 20kg.
STRUCTURE 75O KG
34. Always take care of scaffold tower equipment. Remember your safety depends on the
PLATFORM 250 KG
ALWAYS READ THE INSTRUCTION MANUAL FOR
17. Never climb on horizontal or diagonal braces. Do not gain access or descend from the safe erec�on and use of the equipment.
working pla�orm other than by the intended access system.
ILLUSTRATION
Step 8
Engage Locking Pins . Attach Diagonal Brace from 4th rung Standing on the guarded Platform , �it Fit the stablizer to the base unit, adjust the
to 6th rung on both sides in opposite the 2nd Trapdoor Platform on the 3rd leg of stablizer to give �irm support to the
direction. Diagonal brace must be rung from the Top. ground. Position the Stablizer so that the foot
alligned (zig-zag pattern) pads are approx equidistant from each other
2)Snap pins - Unlock the interlock
at approx 45 degree for maximium stability Clips on all frames. When installed,
always move the interlock clip to the
“Locked” Position.