Hu00 N2XH B2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

N2XH PRO 0,6/1KV B2ca

Halogen-free cables

PRODUCT FAMILY DESCRIPTION


N2XH (s1a,d1, a1) with copper conductor is a Low Smoke Zero Halogen (LS0H) cable. These flame-retardant cables develop much less
and lighter smoke than traditional PVC-cables. And the smoke developed is a lot less toxic. Owing to the fact that the cables have improved
properties under fire, they are recommended for fixed installations in public buildings frequented by large amounts of people, for industrial
complexes, electric power plants, transformer stations, municipal facilities, hotels, shopping malls, hospitals, schools, airports as well as
underground railways. To be laid indoors, in air or concrete. Direct laying in the soil or in water is not permitted.

GENERAL INFORMATION
Brand Prysmian
Application Building Installations;Industrial Installations

STANDARDS

DIN VDE 0276-604 General


DIN EN 60332-1-2 Fire performance
EN-50399 Fire performance
EN 13501-6 Fire performance

CABLE-DESIGN
Conductor material Copper
Conductor surface Bare
Core identification (acc. HD 308 S2) Yes
Core insulation material XLPE
Material outer sheath Low smoke zero halogen
Cable shape Round

CHARACTERISTICS
Outdoor installation Yes
Bending radius (rule) During installation: 15 x D single-core cables; 12 x D multi-core cables

Technical data, dimensions and weights are subject to change. All sizes and values without tolerances are reference values. Specifications are for products supplied by Prysmian: any modification or alteration of
products may give different results. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The
information is correct to the best of our knowledge at the time of publication. Prysmian reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically
authorized by Prysmian. © All rights reserved by Prysmian 2024 • www.prysmian.com

HU00_N2XH_B2_s1d1a1_15/10/2024 P1
CHEMICAL PROPERTIES
Silicon free Yes
Lead free Yes
Flame retardant In accordance with EN 13501-6
Halogen free acc. IEC/EN 60754-1/2
Low smoke (acc. EN 61034-2) Yes
CPR reaction to fire B2ca

ELECTRICAL & THERMAL PARAMETERS


Nominal voltage U0 [V] 600
Nominal voltage U [V] 1,000
Test voltage [kV] 4
Rated voltage U0/U (Um) 0.6/1 (1.2) kV
Max. conductor temperature [°C] 90
Max. conductor temperature at short circuit [°C] 250
Minimum temperature for fix installation [°C] -5
Maximum temperature for fix installation [°C] 50

SUSTAINABILITY COMMITMENT
Our commitment to a low-carbon future remains unwavering as we strive to create sustainable solutions while upholding quality standards. We
prioritize sustainability and environmental protection in our daily operations, collaborating with local communities to ensure workplace safety and
safeguard the areas we operate in.
Sustainability and environmental responsibility is evident also in our packaging solutions across the CEE region. We use fully recyclable drum cover
foils to minimize environmental impact. Our packaging for rings is made from 30% recycled materials, supporting a circular economy. Additionally, our
boxes are made from recyclable, environment-friendly cardboard, promoting eco-conscious choices. By choosing Prysmian, you are not only
selecting high-quality products but also contributing to a greener future.
Check for more details about our sustainability commitment here: Sustainability: report and responsibility.

CABLE PROPERTIES

Nominal Conductor Short circuit


Cable
Basic Conductor Shape of outer resistance at current DOP
Type SAP code weight
construction category conductor diameter 20° C conductor number
[kg/km]
[mm] [Ohm/km] (1sec) [kA]
Class 2 =
1x95 -O Round 20456296 21.6 1,224 0.193 13.6 1019411
stranded
Class 2 =
1x120 -O Round 20456392 23.3 1,479 0.153 17.2 1019411
stranded
Class 2 =
1x150 -O Round 20456393 25.1 1,765 0.124 21.5 1019411
stranded
Class 2 =
1x185 -O Round 20456297 27.1 2,148 0.0991 26.5 1019411
stranded
Class 2 =
1x240 -O Round 20456298 29.8 2,724 0.0754 34.3 1019411
stranded
Class 2 =
1x300 -O Round 20456394 32.2 3,321 0.0601 42.9 1019411
stranded
Class 2 =
1x400 -O Round 20456395 35.4 4,172 0.047 57.2 1019411
stranded
Class 2 =
1x500 -O Round 20456401 39 5,241 0.0366 71.5 1019411
stranded
3x1,5 -J Class 1 = solid Round 20457104 10.9 174 12.1 0.21 1019412
Class 2 =
3x35 -J Round 20456398 26.8 1,616 0.524 5.01 1019412
stranded
Class 2 =
3x50 -J Round 20456402 29.8 2,092 0.387 7.15 1019412
stranded
Technical data, dimensions and weights are subject to change. All sizes and values without tolerances are reference values. Specifications are for products supplied by Prysmian: any modification or alteration of
products may give different results. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The
information is correct to the best of our knowledge at the time of publication. Prysmian reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically
authorized by Prysmian. © All rights reserved by Prysmian 2024 • www.prysmian.com

HU00_N2XH_B2_s1d1a1_15/10/2024 P2
CABLE PROPERTIES

Nominal Conductor Short circuit


Cable
Basic Conductor Shape of outer resistance at current DOP
Type SAP code weight
construction category conductor diameter 20° C conductor number
[kg/km]
[mm] [Ohm/km] (1sec) [kA]
Class 2 =
3x70 -J Round 20456300 33.9 2,839 0.268 10.2 1019412
stranded
Class 2 =
3x95 -J Round 20456397 37.6 3,729 0.193 13.6 1019412
stranded
Class 2 =
3x120 -J Round 20456299 41.7 4,641 0.153 17.2 1019412
stranded
Class 2 =
3x150 -J Round 20456396 45.8 5,638 0.124 21.5 1019412
stranded
Class 2 =
3x185 -J Round 20456414 50.4 6,962 0.099 26.5 1019412
stranded
Class 2 =
3x240 -J Round 20456403 56.2 8,947 0.075 34.3 1019412
stranded
Class 2 =
4x35 -O Round 20456406 28 1,931 0.524 5.01 1019412
stranded
Class 2 =
4x50 -O Sector-shaped 20456411 30.5 2,319 0.387 7.15 1019412
stranded
Class 2 =
4x50 -O Round 20456404 32.1 2,559 0.387 7.15 1019412
stranded
Class 2 =
4x70 -O Sector-shaped 20456399 34.7 3,183 0.268 10.02 1019412
stranded
Class 2 =
4x95 -O Sector-shaped 20456413 38.6 4,216 0.193 13.6 1019412
stranded

Technical data, dimensions and weights are subject to change. All sizes and values without tolerances are reference values. Specifications are for products supplied by Prysmian: any modification or alteration of
products may give different results. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The
information is correct to the best of our knowledge at the time of publication. Prysmian reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically
authorized by Prysmian. © All rights reserved by Prysmian 2024 • www.prysmian.com

HU00_N2XH_B2_s1d1a1_15/10/2024 P3
CABLE PROPERTIES

Nominal Conductor Short circuit


Cable
Basic Conductor Shape of outer resistance at current DOP
Type SAP code weight
construction category conductor diameter 20° C conductor number
[kg/km]
[mm] [Ohm/km] (1sec) [kA]
Class 2 =
4x120 -O Sector-shaped 20456400 42.1 5,188 0.153 17.2 1019412
stranded
Class 2 =
4x150 -O Sector-shaped 20456415 46.4 6,336 0.124 21.5 1019412
stranded
Class 2 =
4x185 -O Sector-shaped 20456412 51 7,812 0.991 26.5 1019412
stranded
Class 2 =
4x240 -O Sector-shaped 20456417 56.8 10,096 0.075 34.3 1019412
stranded
Class 2 =
5x16 -J Round 20456416 25.2 1,303 1.15 2.41 1019412
stranded
Class 2 =
5x25 -J Round 20456418 28.6 1,846 0.727 3.58 1019412
stranded
Class 2 =
5x35 -J Round 20456405 31.5 2,386 0.52 5.01 1019412
stranded
Class 2 =
5x50 -J Round 20456407 35 3,111 0.38 7.15 1019412
stranded
Class 2 =
5x70 -J Round 99991231 39.74 4,251 0.268 10.02 1019412
stranded

Technical data, dimensions and weights are subject to change. All sizes and values without tolerances are reference values. Specifications are for products supplied by Prysmian: any modification or alteration of
products may give different results. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The
information is correct to the best of our knowledge at the time of publication. Prysmian reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically
authorized by Prysmian. © All rights reserved by Prysmian 2024 • www.prysmian.com

HU00_N2XH_B2_s1d1a1_15/10/2024 P4

You might also like