Catalog - Complete 2012 - BARDAC
Catalog - Complete 2012 - BARDAC
Catalog - Complete 2012 - BARDAC
INTERNET
drive.web AUTOMATION
AC DRIVES
DC DRIVES
Bardac
MOTORS
SERVICE
Since our founding in 1992 we have worked hard to build our reputation around key goals: Innovative technologies. Reliable products. Unrelenting customer support. All catalog items normally in stock. Competitive pricing.
Bardac
Nothings changed!
Page
3-5 6-7 8-9 10 - 11 12 - 15 12 - 15 15 - 21 22 - 23 24 - 25 26 - 27 28 - 29 30 - 31 32 33 34 - 35 36 - 38 39 40-45 46 46 46 47 47 48
AC DRIVES
drive.web Automation technology savvy design & configuration tools savvy-SFD Signal Flow Diagram tools savvyPanel touch screen HMI technology drive.web Automation Products: smarty speedy drive.web apps Engineered Applications Winders, process line coordination, registration, line shaft, indexing AC Drives Overview Closed Loop Vector - up to 350 HP Sensorless Vector - up to 250 HP HVAC, fans & pumps - up to 350 HP General Purpose VFDs - up to 15 HP NEMA 12 & NEMA 4 Drives - up to 100 HP Drive options Single Phase SP & PSC motor controls - up to 1.5 HP DC Drives - Single Phase - up to 10 HP Servo - up to 2 Amps 3-Phase - up to 2000+ HP AC & DC Motors, Motor Accessories Modulus Packaged Drives Power Quality, Drive Isolating Transformers, Line Reactors & Line Filters Online Product Support & Training Customer Support, Service, Safety, Quality, Environmental Notes, Terms Index
Specifications ... At the time of going to press we believe the information in this catalog to be accurate. However, the specifications of products may be amended at any time, so please check with us when ordering to ensure that such changes will not affect your requirements.
COST EFFECTIVE FOR SYSTEMS OF ANY SIZE OR COMPLEXITY WORLD CLASS - NO EQUAL!
speedy ModbusTCP/IP Gateway Programmable Controller with USB port for total system access
savvyPanel Touch screen operator stations with control tools & WiFi roaming. For PC, iPad or iPhone
Build and operate complete control systems over Ethernet Program individual drives, controllers & operator stations Make drag & drop connections between devices Configure touch screen PC operator stations Create roaming HMIs in iOS devices - iPad, iPhone, etc. Provide Internet access to your entire system Add utilities such as watchdogs, event emails, loggers, etc. Support interfaces to existing devices via Modbus, EIP, etc.
Bardac.com
drive.web automation
drive.web
1
CONCEPT & PLANNING
From your initial sketches and notes create drive.web savvy Phantoms offline to identify all your drives, remote i/o, MMI interfaces, gateways, etc.
drive.web uses distributed control over Ethernet to provide cost effective, high
Place any control function blocks you need then drag & drop between parameters in your Phantoms to make all your device interconnections. The savvy Signal Flow Diagrams and powerful navigation aids give you a clear intuitive view of your work. Information and help is always on the spot with hover text, links to the manual and contextual menus.
From the initial concept, through planning, design, construction, testing, installatation and operation the drive.web savvy tools provide all the vision, insight and help you need for a successful project.
3 4
Simply connect all your drives and devices together over Ethernet and load your complete design into the devices form just one location. The system immediately comes alive for testing and monitoring.
Use drive.web savvy to provide real time monitoring and control of your entire system from any location. No running from drive to drive to check the set up or operational state! Use savvyPanel operator station technology to provide smart touch and roaming control from anywhere.
L
PRODUCTIVITY
Use savvy utilities to set up system performance criteria and monitor your productivity, machine state and process trends locally or remotely over the Internet.
smart automation
Configure & control individual drives & devices Design and operate complete drive systems Provide fast, peer-to-peer networking over Ethernet Create clear, graphical signal flow system documentation Easily interface to most other drives, MMIs, PLCs, etc. Build cost effective systems of any size or complexity Add Internet accessibility to your system Support worldwide enterprise integration
The innovative drive.web technology provides total control in one homogeneous environment with the entire system database resident in the drive.web devices.
products
savvy
Intuitive, graphical system design and device configuration tools with powerful navigation features, drag & drop connections, trend charting and online help.
savvyPanel
Innovative, touch screen operator station technology that runs on PC or iOS (iPad, iPhone, etc.). Build clear machine graphics, buttons, switches, meters and instrumentation and link to your control scheme. Provides multi-user, multi-level, password protected access via WiFi from anywhere to any system.
smarty
A range of drive.web programmable controllers with peer-to-peer networking over Ethernet or stand alone capability and a wide range of i/o and communications options. Intuitive, easy function block configurations are stored on board for instant field access.
speedy
A range of miniature, low cost, drive.web programmable controllers with peer-to-peer networking over Ethernet. Easily interfaced to almost any drive or control device.
Bardac.com
drive.web automation
savvy ... the smart automation tool.
Configure complete systems of any size or complexity. Provide multi-user, total access to your drives and systems from anywhere. Engineering Info
In complex products with a fixed set of features, such as drives, an Engineering Info window gives a organized overview of the key parameters, i/o and control features.
Simply click on any function button to drill down to the detailed graphical function block and view or change parameter values.
Standard Features Online or offline design of drive systems using intuitive tools with pre-engineered function blocks. Internet access to drives and systems for remote configuration, monitoring and process training. Provides easy import, export and cloning of device configurations. Dynamic graphics show real time state of switches, indicators, parameter values, etc. Low cost, full featured, Distributed Control capability with peer-to-peer networking. Multiple users, local or remote, can have concurrent real-time access to drives or systems. Function Block Libraries for winder controls, PID, drive synchronization, arithmetic, logic, etc. Deterministic connections provide high performance links between drives, PLCs, Operator Stations,
6
SCADA computers and other control products. drag & drop techniques make easy parameter connections between drives, control devices, etc. Dock feature enables key system parameters to be monitored and trended from one location. Powerful navigation features include drill down (to detail layers in drives and controllers), search, connection tags, jump, browse, pan and zoom for easy visual system comprehension. VPN (Virtual Private Networking) for secure Internet connectivity is supported. Password protection is provided at many levels for secure use.
Right click on any active object such as a device, connection, parameter or function block to open the contextual menu Hover over any active object and see its key data appear at the top of the window. Hover over a button to see its function described. Look out for the information button. This will jump you to the relevant location in the user manual. The Help menu links you to the full user manual, and other getting started guides.
Trend Charting
You can collect any parameters of interest in a dock window and display as a trend chart. The trend time scale can be adjusted from 10 seconds to 2 days and the data can be exported in a .csv format for separate spreadsheet analysis.
Bardac.com
drive.web automation
savvy-SFD ... Signal Flow Diagram
The savvy-SFD option provides a powerful, graphical, Signal Flow Diagram interface with enhanced system wide navigation and the ability to produce clear, annotated, device and system documentation. Use savvy phantoms to create systems which can be downloaded later into the real devices.
savvy-SFD features
8
Basic savvyPanel operator station functions included Create your own customized drawing sheets with choice of ISO or ANSI formats Signal flow diagrams provide a clear vision of your control scheme and its functionality Tags clearly specify the source, destination and location of connections between multiple pages. Entire drawing is stored in the drive.web devices for instant access in the field. Key parameters can be shown at the Signal Flow Diagram level for enhanced monitoring and control Connections are rubber banded so that function blocks can be moved on pages or between pages drag & drop connections can be made between any parameter anywhere in a system. Drawings can be user annotated. Powerful navigation features ensure fast searches and that you will never get lost. Password protection is provided at many levels for secure use.
savvy programming
It could not be easier, whether simply configuring a drive or designing a complete integrated system. A few simple steps are all that is needed to build a complete control scheme with signal flow documentation that is clear and easy to understand. Powerful navigation tools ensure that you will never get lost!
Create phantom devices or find real devices in your system in the Device Directory window.
Right click on any device or object to open its contextual menu and get information, change names, import/export data, etc.
5 6
Click on a Function Block to drill down to the detail level ...
Function Blocks are complete engineered system components. Their graphics are dynamic so that objects such as switches, indicators, etc., show their instantaneous state. A function block such as the PID above includes all the presets, resets, scaling, filters, clamps, etc., that you need for reliable implementation in the real world. savvy is your smart friend! With a few simple clicks you can build a system, set up a drive and document your work in a thoroughly professional manner - there is no equal!
Bardac.com
Operator Screen Touch a graphic tile such as the EXTRUDER to drill down to the detail screen
Total Control Touch an arrow link such as the TEMP CONTROL tile to drill down to the temperature control system Touch the MELT TEMP tile in any screen to set the master temperature setpoint.
10
Walk around your machine with complete control at your finger tips! Roam around your plant and access every machine and process with ease! View your operations live, anywhere in the world, any time you like!
C Touch the Roll Change button to reset the roll length to zero C Turn on all the section On/Off switches C Touch the Line Start button and watch the line accelerate, run and
automatically slow down to stop at the required length.
C Touch the Set Speed indicator at any time to change the line speed J Touch the parameter name to get info J Touch the square display symbol to close the setter
very smart automation!
Key features Auto screen orientation with lock Pinch to zoom Drag to pan Double tap for home Touch to open setters (Quickly flip to phone to tell the boss how well things are going or to order a pizza)
Bardac.com
11
drive.web automation
smarty & speedy ...
The drive.web smarty & speedy programmable controllers use distributed control over Ethernet to provide cost effective, high performance integration in systems of any size or complexity.
No system bandwidth degradation with systems of any size One completely homogeneous environment for drives, controls, operator stations, i/o - everything! Complete data consistency throughout a system The ability to store the entire system configuration in the controllers for easy field total access The ability to manage total system program thread and hierarchy Consistent multi-level password protection
Key Features:
Ethernet peer-to-peer networking Gateway options for ModbusTCP/IP, EIP CANopen and others Internet access Graphical Signal Flow Diagram system documentation Additional i/o Easy interface to most operator stations, PLCs, SCADA, etc. Event driven emails from devices
Precision
16 bit integer basic arithmetic 32 bit floating point calculator functions 64 bit encoder pulse counting
For iPad, iPhone, iPad and touch screen PC operator stations with arrows, meters, start and stop pushbuttons.
smarty
Adders, Subtracters, Multipliers, Dividers, Clamps, Switches, Logic Event driven email messages Full featured PI controllers
speedy
12
Winders & unwinders Web tension control Process line multi-drive coordination Position control Indexing Cyclic position control Electronic line shaft
Spindle orientation Registration control Encoder feedback for open loop drives Cut-to-length Speed profiling, MOP & draw Process recipe and mode control Temperature & process control
Used for all programmable control, peer-to-peer Ethernet networking and system integration tasks.
Easy interface to most drives Use networked or stand alone Internet accessible Peer to peer deterministic Ethernet networking 100baseTX or 10baseT Ethernet with auto-negotiation Full duplex supported Auto-MDIX per IEEE802.3ab (auto-crossover resolution) Optional Power over Ethernet (PoE, IEEE 802.3af) drive.web distributed control Intuitive, graphical function block programming tools Complete graphical configuration & documentation data stored in devices 16 basic i/o terminals each configurable includes: 8: 10V, 16 bit analog in or out or 24V digital in 8: 0-10V 16 bit analog in or 24/12/5V dig in or 24V dig out, source or sink Firmware field upgradable All circuit boards conformal coated for very high reliability SNTP server time/date synchronization support 100% backward compatible with all existing drive.web installations
Optional Features:
Smart, compact packaging 4 high x 4.75 deep x 0.9 wide (102 x 120 x 22 mm)
Full savvyPanel touch screen PC and iOS device capability Encoder input without marker 1 or 2 encoder inputs with marker and retransmit via external module 1 or 2 isolated or unisolated RS485 ports High voltage digital i/o isolator 6 additional digital inputs 4 channel 20KHz frequency i/o 24 channel extended digital i/o External thermocouple and RTD inputs ModbusTCP/IP, ModbusRTU, EIP/PCCC USB port for system wide programming coming soon
Serial interfaced to drives and third party devices via ModbusRTU or CANopen to provide low cost, improved performance, peer-to-peer Ethernet networking and full programmable control functions. So small it fits anywhere, does everything! Includes USB port for system wide programming and Ethernet ModbusTCP/IP. Available in either bond mount with tether or DIN rail mount with screw terminals or tether or embedded form.
Bardac.com
13
drive.web automation
smarty ... Models
dw210 dw211 dw212 dw213 dw214 dw215 dw216
Smart controllers with 100baseTX Ethernet, distributed control, 16 configurable analog/digital i/o and a wide range of i/o and communications options
smarty for standalone or networked applications General purpose programmable controller or drive interface controller smarty-sp dedicated interface controller for PL/X series DC Drives (mid 2012) smarty dedicated interface controller for ODE2 General Purpose AC Drives smarty dedicated interface controller for ODP Sensorless Vector Drives smarty dedicated interface controller for ODP2 Closed Loop Vector Drives smarty dedicated interface controller for Yaskawa F7 drive smarty dedicated interface controller for ODV2 HVAC & Pump Drives
Miniature smart controllers with 100baseTX Ethernet, ModbusTCP/IP, distributed control, USB port, serial port and a wide range of communications options
speedy generic interface controller with ModbusRTU master, DIN mount, w/terminals speedy plug-in controller for PL/X series DC drive speedy plug-in controller for ODE2 General Purpose drive speedy plug-in controller for ODP Sensorless Vector drive speedy plug-in controller for ODP2 Closed Loop Vector drive speedy plug-in controller for Yaskawa F7 drive speedy plug-in controller for ODV2 HVAC & Pump drive
Function Block Libraries -05 Advanced Process Control Function Block Library (FBL) (comparators, profilers, presets, latches, filters, counters, timers, PIDs and more) -06 Winder Control FBL (dia. calc., taper tension., torque comp.) -10 Advanced Math FBL (trigonometric, log, exponential) -11 Encoder Control FBL (shaft lock, indexing, registration for Options 40-44) -29 Solar FBL with sun position calculator Communications Options -04 Ethernet Modbus TCP/IP slave -25 Ethernet EIP/PCCC interface for AB PLCs -14 Power over Ethernet (2W max external load) -17* ModbusRTU slave (RS485) isolated port -18* ModbusRTU slave (RS485) isolated port + external encoder module interface port -19* ModbusRTU slave (RS485) isolated port + ModbusRTU (RS485) master unisolated -23* ModbusRTU master (RS485) isolated port + external encoder module interface port I/O Options -24* 6 extra digital inputs, 24V -26 savvyPanel iPad/iPhone & touch screen PC operator station interface -27* Frequency i/o, up to 20KHz. 2 ~in, 2 ~i/o, with 12V, 400mA regulated power supply -28* Extended digital i/o interface for Opto22 racks (24 channels) -30 115VAC digital i/o voltage isolator, up to 2 per smarty (each with 2, NO contacts + common and 4, 115VAC inputs +common) -31 230VAC digital i/o voltage isolator, up to 2 per smarty (each with 2, NO contacts + common and 4, 230VAC inputs +common) Encoder I/O Options -15* Internal encoder input (2-24V, differential A & B (no marker) w/5VDC encoder supply) -16* External encoder module interface port smarty external encoder module (needs a smarty dw210 option -16, -18, -22 or -23) -40 1 external encoder, 2-24V + marker, 5VDC encoder supply & two 24V event inputs or -42 2 external encoder, 2-24V + marker, 5VDC encoder supply & two 24V event inputs -45 External encoder module RS422 retransmit outputs (1A, 1B, 2A, 2B) or -46 External encoder module 24V retransmit outputs (1A, 1B, 2A, 2B) * Options are mutually exclusive X = Available if not excluded
OPTIONS
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X
X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
S = Standard feature
14
smarty
speedy
speedy-sp
MODEL dw111- speedy-sp for PL-Series Digital DC Drives Open card, mounts internal to drive and plugs directly onto the high speed option bus to provide high performance peer-to-peer networking over Ethernet and drive.web programmable control functions. Note: Fully compatible with Sprint Electric PL and Eurotherm Controls ERPL DC drives. Available Options: 02, ModbusRTU Slave also, 04, 05, 06, 10
Dimensions: 7.8w, 4.0h, 1.5d (198, 101, 38mm)
drive.web apps
Pre-configured, engineered solutions for common applications
These options are pre-programmed units with generic solutions for key applications. The packages are a great design aid. They include basic signal flow diagram and wiring drawing documentation and are easily edited to suit your specific installation using savvy with the SFD Signal Flow Diagram option.
smarty
dw210 dw21 1 dw212 dw213 dw214 dw215 dw216 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
speedy
dw220 dw221 dw222 dw223 dw224 dw225 dw226 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X
Bardac.com
15
These generic configurations can easily be edited by the intuitive drive.web savvy graphical tools to suit the particular application. The clear signal flow diagrams are stored in the controllers for reliable access in the field. The basic smarty packages include 16 flexible analog/logic i/o in a small DIN rail mounting, Internet accessible unit (4.1 high, 4.8 deep, 0.9 wide) with 10/100baseTX Ethernet and plug-in terminals. Standard features include: Fully editable configurations and drawings Process control & winder function block libraries Web break sensing Diameter memory, preset and hold Optional features include: Linear or hyperbolic taper tension Over/under winding Multiple core presets Line drive coordination Integral reset Manual or auto-splicing modes Adaptive control for high speed systems Encoder inputs Standstill tension mode ModbusTCP/IP over Ethernet Jog/run/slack take up modes Serial communications Turret indexing mode ... and more. Anti-reverse clamps Core speed matching
16
easy to interface to most line and winder drives, operator stations and PLCs over Ethernet, RS485 serial communications or via analog and logic wired connections
Download the savvy programming tools free from www.driveweb.com and edit the demo phantom controllers or create your own phantoms
Try it out!
Bardac.com
17
drive.web automation
smarty app
OPTION-1106 Process Line Coordination
Standard function blocks used in combinations of smartys and speedys can be easily configured to provide line drive coordination in systems of any size or complexity.
ETHERNET LAN
Functions such as linear, S and hyperbolic ramps are used to provide master references. Programmable logic and switch functions are used to provide line run, line jog, local jog, interlocks, etc. PIDs, profilers, registration, indexing, phase lock and arithmetic blocks provide precise section control. Torque compensators, diameter calculators and taper functions are used for winder control.
18
smarty app
Encoder retransmit
Encoder retransmit
Ethernet
The Registration & Electronic Line Shaft package is designed for applications such as print registration, synchronized component handling, position control, cut-to-length, etc., where precision drive coordination and spindle orientation are required.
Standard graphical function blocks for registration and speed locking make these complex processes quick and easy to configure and use. The encoder retransmit option provides buffered encoder signals for secure use in multiple locations.
Bardac.com
19
drive.web automation
smarty app
OPTION-1117 Indexing & Cyclic Positioning
The optional Encoder Function Block Library available in the smarty includes a set of engineered function blocks for use in precision positioning applications such as packaging machines, machine center tool loaders, inventory carousels, stackers, etc.
Key features
Auto origin checking Auto index calculation Auto calculation of shortest move from point to point 64-bit encoder counts
smarty app
The Solar Function Block Library includes functions that provide precision calculation of the sun zenith and azimuth angles for use in applications such as solar energy systems. The units can be synchronized with the SNTP server time and date and include a T input parameter to compensate for the difference between UTC and Terrestrial Time for precise positioning of parabolic solar concentrators.
Key Features
Set up for any latitude, longitude and altitude. Fast calculation for use in mobile systems. SNTP synchronization support. Terrestrial Time correction input.
20
drive.web
smart utilities
The E-Mail function block available in every drive.web device enables you to send alerts, event notices, status reports, etc., to management, quality controllers, plant engineers in any location. It is easy to set up and it ensures that key process issues are delivered to the right place at the right time.
drive.web
smart ideas
There are many inexpensive third party WiFi routers that when plugged into a drive.web Ethernet network provide secure, robust, roaming system access in an industrial environment using an iOS device such as an iPad or iPhone.
drive.web technology provides a great backbone on which to build integrated solutions in your entire global enterprise without additional complex data processing requirements. Multilevel password protection enables safe access for offsite accountants, production controllers and corporate management.
The IP addressing capability in every drive.web device ensures easy support for field service and live online training for machine operators, system designers, plant maintenance engineers, etc. If an internet connection is available near your machine or process it takes less than 1 minute to set up a live connection to our engineers or any other off site location. drive.web provides system wide access from any single location on your LAN - very smart, very easy!
Bardac.com
21
AC drives
Bardac.com
23
AC drives
OPTIDRIVE P2
0.5 TO 350 HP
Multiple Modes: Closed Loop Vector for high performance Open loop PM Motor Control Sensorless vector & V/Hz control Up to 200% torque at zero speed Sensorless speed regulation better than 1% Torque control DC bus sharing Safe Torque Off function Output to 500Hz (V/F Mode), 100Hz (Vector Mode) Built-in 100% rated DB transistor up to 350HP Integral PI controller drive.web savvy function block programming Silent running with up to 32KHz switching 200% starting torque Bipolar 12 bit analog input (isolated +/-10V or 4-20mA) ModbusRTU, RS485 port CANopen port Filters & DC chokes 25-250 HP, line chokes 300-350HP Single phase input up to 125 hp Power loss ride through Process control options Programmable i/o Hours run log & trip log Cartridge fans for easy maintenance (NEMA12 drives) Options: Encoder feedback Additional basic & smarty i/o options EIP, Modbus TCP/IP, Profibus, DeviceNet, BACnet Memory stick with bluetooth interface Remote keypad 2Khz output in V/Hz mode OLED text display
Dimensions Size
Height (ins) Height (mm) Width (ins) Width (mm) Depth (ins) Depth (mm)
The drive.web automation technology uses distributed control over Ethernet to provide cost effective systems integration for systems of any size or complexity. savvyPanel Easy operator stations options with touch screen PCs or iOS devices such as iPad, iPhone
powerful programmable control functions peer-to-peer over Ethernet smart iPad or touch screen PC operation Easy system wide Internet access
24
Specifications
Input Ratings Supply Voltage Supply Frequency Displacement PF Phase Imbalance Inrush Current Power Cycles Output Ratings Power Output 200 - 240 10% 380 - 480 10% 48 - 62 Hz > 0.98 3% Maximum allowed < Rated current 120 per hour max, evenly spaced 230V, 1-ph in: 1-3 HP (0.75-2.2 kW) 230V, 3-ph in: 1-120 HP (0.75-90 kW) 400V, 3-ph in: 0.75-160kW 460V, 3-ph in: 1-350 HP 150% for 60 secs, 200% for 4 secs. 0-500Hz in V/Hz mode (0.1 Hz res) (optional 2KHz) 0-100Hz in vector made Storage: -40C to 60C Operating: -10C to 40C (IP40, IP55 & IP66) -10C to 50C (IP20) Up to 1000m ASL without de-rating Up to 2000m Max UL Approved Up to 4000m Max (non UL) Above 1000m, de-rate 1% per 100m 95% non-condensing IP20 - Frame sizes 2 & 3 IP40 (NEMA 1) - Frame size 8 IP55 (NEMA 12) - Frame sizes 4 to 7 IP66 (NEMA 4X) - Optional sizes 2 & 3 Standard: built in keypad Optional: Remote keypad Optistick memory stick drive.web savvy software Bright red LED (sizes 2 & 3) Bright Green OLED text (sizes 4 to 7) Closed Loop (encoder) speed control Closed Loop (encoder) torque control Open Loop PM vector control Sensorless vector speed control V/F Voltage vector Energy optimized V/F 4 - 32 kHz effective Ramp to stop - adjustable 0.1-600 secs Safe Torque Off mode Motor flux braking (DC injection) Built in brake transistor Single point user adjustable 0-10v, 10-0v, 10v 0-20mA, 20-0mA, 4-20mA, 20-4mA Keypad ModbusRTU CANopen Optional drive.web Ethernet distributed control + programmable control, extra i/o, operator stations drive.web, ModbusTCP, EIP, DeviceNet, Profibus 24VDC, 100mA short protected 10VDC, 5mA for setpoint potentiometer 3 x Digital 10 to 30 VDC, response <4ms 2 x Analog/digital 2 x Analog, 0-10V, 0-20mA, 4-20mA 2 x Relay NO, 6A @ 250VAC, 5A @ 30VDC Internal PID with feedback display Last 4 trips stored with time stamp Current, temperature, DC Bus volts prior to trip Service life monitor with user adjustable interval Hours run Resettable and non-resettable kWh meters
Ambient Ratings
Temperature
Altitude
With EMC Filter, DB transistor, DC Chokes 200-240V 10%, 3-ph in, 230V, 3-ph motor Model HP Amps Size ODP2-42075-3HF4N 7.5 24 4 ODP2-42100-3HF4N 10 30 4 ODP2-42150-3HF4N 15 46 4 ODP2-52020-3HF4N 20 61 5 ODP2-52025-3HF4N 25 72 5 ODP2-62030-3HF4N 30 90 6 ODP2-62040-3HF4N 40 110 6 ODP2-62050-3HF4N 50 150 6 ODP2-62060-3HF4N 60 180 6 ODP2-72075-3HF4N 75 202 7 ODP2-72100-3HF4N 100 248 7 ODP2-72120-3HF4N 120 312 7 380-480V 10%, 3-ph in, 460V, 3-ph motor Model HP Amps Size ODP2-44150-3HF4N 15 24 4 ODP2-44200-3HF4N 20 30 4 ODP2-44250-3HF4N 25 39 4 ODP2-44300-3HF4N 30 46 4 ODP2-54040-3HF4N 40 61 5 ODP2-54050-3HF4N 50 72 5 ODP2-64060-3HF4N 60 90 6 ODP2-64075-3HF4N 75 110 6 ODP2-64120-3HF4N 120 150 6 ODP2-64150-3HF4N 150 180 6 ODP2-74175-3HF4N 175 202 7 ODP2-74200-3HF4N 200 240 7 ODP2-74250-3HF4N 250 302 7 Size 8 with EMC filter, DB transistor & line choke ODP2-84300-3HF44 300 370 8 NEMA 1 ODP2-84350-3HF44 350 450 8 NEMA 1 For single phase supply derate to 50% OPT2-ENCOD-IN Encoder feedback module OPT2-OPORT-IN Remote Keypad & Display
Programming
Keypad
Display
Control
Control Modes
Modulation Stop Mode Braking Skip Frequency Analog Setpoint Control Digital Setpoint Control
Automation Communications Options I/O Specification Power Supply Programmable Inputs Programmable outputs
Bardac.com
25
AC drives
OPTIDRIVE PLUS
SENSORLESS VECTOR DRIVES
0.5 TO 250 HP
GV 3 Technology Sensorless vector control 100% torque at zero speed Sensorless speed regulation better than 1% Encoder feedback speed regulation better than 0.1% Torque control Output to 500Hz (optional 2KHz) Output to 100Hz (Sensorless Vector Mode) Integral PI controller Rugged compact IP20 packaging Silent running with up to 32KHz switching 175% starting torque Built-in DB transistor available up to 250 hp Bipolar 12 bit analog input (isolated +/-10V or 4-20mA) ModbusRTU, RS485 port up to 115kbps Filters & line chokes available 25-250 hp Fiber optic & RS232/485 network options Optiwand optical programming tool Single phase input up to 60 hp Isolated control circuits Power loss ride through Process control options Programmable i/o Digital inputs 2 Analog inputs 1 Analog/digital inputs 1 Analog Outputs 1 Relay contact output 1 Hours run log 50C ambient Options Additional smarty i/o option Ethernet, Modbus TCP/IP option drive.web savvy programming option Encoder feedback option (better than 0.1%)
Automation Options
STANDARD IP20 ENCLOSED DRIVES SIZE HIGH WIDE DEEP LBS 1 6.1 3.15 5.1 2.5 2 10.25 3.95 6.9 5.9 3 10.25 6.75 6.9 12 4 20.5 13.4 8.7 63 Size 5, up to 150 amps 41.2 13.4 8.7 151 Size 5, 180 amps & over, 41.2 13.4 13 151 6 44.5 13.4 13 153 Size 6 Ext Choke 9.5, 9.8, 9.1 (240, 250, 230mm) NEMA 12 DRIVES 1 7.9 2 12.2 5.5 6.5 6.4 6.9 5.4 10.3
drive.web
savvyPanel
(150, 80, 130mm, 1.1kg) (260, 100, 175mm, 2.6kg) (260, 171, 175mm, 5.3kg) (520, 340, 220mm, 28kg) (1045, 340, 220mm, 67kg) (1045, 340, 220mm, 67kg) (1130, 340, 330mm, 68kg)
Easily add smart, graphical, operator stations with an iPad, iPhone or touch screen PC.
T h e smar ty o p t i o n provides drive.web Internet accessible distributed control technology over Ethernet together with powerful programmable automation features
smarty
26
AMPS 2.3 4.3 7.0 7.0 10.5 AMPS 14 18 24 39 46 61 72 90 110 150 240 300 AMPS 2.2 4.1 5.8 9.5 14 18 24 29.5 * 39 46 61 72 88 110 150 180 202 240 300
Heavy duty, 150%, 60 sec., 50C rating Full torque at zero speed Open loop speed regulation better than 1% Nema 12 versions up to 7.5HP Hours run & KWh store RS485 up to 115Kbps 12 bit bipolar analog inputs Plug-in control terminals Spin start
SPECIAL FEATURES HP @ 575V AMPS Filter, Brake Transistor - needs choke (CO502628) 1 1.7 Filter, Brake Transistor - needs choke (CO502628) 2 3.1 Filter, Brake Transistor - needs choke (CO502628) 3 4.1 External 600V Line choke required for above drives Filter, Brake Transistor - needs choke (CO502629) 5 6.1 Filter, Brake Transistor - needs choke (CO502629) 7.5 9.0 External 600V Line choke required for above drives Filter, DC Chokes, Brake Transistor 10 14 Filter, DC Chokes, Brake Transistor 15 18 Filter, DC Chokes, Brake Transistor 20 24 Filter, Line Chokes, Brake Transistor 30 39 Filter, Line Chokes, Brake Transistor 40 46 Filter, Line Chokes, Brake Transistor 60 62
ENCODER OPTIONS
ODP-ENCOD-US Encoder feedback option For precision speed control RTX Encoder retransmit option provides secure buffered encoder pulse output from the encoder feedback module
SIZE HP AMPS UNSWITCHED SWITCHED 2 1.0 1.7 ODP-25010-US-** ODP-25010-US-iS 2 2.0 3.1 ODP-25020-US-** ODP-25020-US-iS 2 3.0 4.1 ODP-25030-US-** ODP-25030-US-iS 2 5.0 5.8 ODP-25050-US-** ODP-25050-US-iS OD-IL163-US-i55 NEMA 12, 3-phase, line inductor required for 1 to 5HP, 600V drives above 2 7.5 9.0 ODP-25075-US-** ODP-25075-US-iS OD-IL263-US-i55 NEMA 12, 3-phase, line inductor required for 7.5HP, 600V drive above
UNSWITCHED drives have Nema 12 keypad and display SWITCHED drives have additional power isolator switch, FWD/REV switch & speed pot
Bardac.com
27
AC drives
V2 SERIES HVAC
VARIABLE TORQUE FAN & PUMP DRIVES
FEATURES
Dedicated HVAC and centrifugal pump controller Built in EMC filter standard DC bus chokes built in, sizes 4 - 7, line choke size 8 NEMA4X (IP66) to 10HP, NEMA12 (IP55) 10-250HP NEMA1 (IP40) 300-350 HP Multi-language, plain text OLED display for ease of use Energy optimization for maximum efficiency BACnet and ModbusRTU as standard Built-in hours run and kWh meters Built-in PID controller Advanced application functions for easy programming Engineered function blocks for optimum performance High frequency switching (up to 32kHz) for quiet running Built-in sleep and wake functions for on demand use Built-in motor flux braking Programmable i/o Optistick plug-in programming tool Power loss ride through 40C ambient HVAC functions: Bi-directional Fire Mode for emergency ventilation Pump functions: Blockage detection Adjustable cleaning cycle Multi-pump cascade control Pump stir mode Options: drive.web savvy smart automation savvyPanel graphical, touch screen operator technology Easy, off site Internet access to the complete system Ethernet peer to peer networking Ethernet ModbusTCP and EIP 3 additional relay outputs for cascade control Additional smarty i/o option Built in power isolator switch sizes 2 & 3 Standards - CE, C-Tick, (UL, C-UL, Pending)
0.5 TO 350 HP
Fan & pump features NEMA 4X (IP66) to 10 HP NEMA 12 (IP55) to 250 HP NEMA 1 (IP40) to 350 HP BACnet & ModbusRTU smart drives
Use the easy drive.web option to build smart controls schemes and iOS or PC graphical touch screen operator stations with roaming access, diagnostics and event driven email.
powerful programmable control functions peer-to-peer over Ethernet smart iPad or touch screen PC operation Internet access The drive.web speedy Ethernet interface and automation controller mounts inside the drive enclosure for protected, reliable operation. It includes a USB port for easy system wide programming.
28
Specifications
Input Ratings Supply Voltage Supply Frequency Displacement PF Phase Imbalance Inrush Current Power Cycles Output Ratings Power Output 200 - 240 10% 380 - 480 10% 48 - 62 Hz > 0.98 3% Maximum allowed < Rated current 120 per hour max, evenly spaced 230V, 1-ph in: 1-3 HP (0.75-2.2 kW) 230V, 3-ph in: 1-120 HP (0.75-90 kW) 400V, 3-ph in: 0.75-160kW 460V, 3-ph in: 1-250 HP 110% for 60 secs, 125% for 2 secs. 0-120Hz, 0.1 Hz resolution Storage: -40C to 60C Operating: -10C to 40C Up to 1000m ASL without de-rating Up to 2000m Max UL Approved Up to 4000m Max (non UL) Above 1000m, de-rate 1% per 100m 95% non-condensing NEMA4X (indoor) sizes 2, 3; NEMA12 sizes 4 to 7 Standard: built in keypad Optional: Remote keypad Optistick memory stick drive.web savvy software Standard: Bright Green OLED Variable torque V/F Variable torque Energy optimized V/F 4 - 32 kHz effective Ramp to stop - adjustable 0.1-600 secs Coast to stop Motor flux braking (DC injection) Single point user adjustable 0-10v, 10-0v, 10v 0-20mA, 20-0mA, 4-20mA, 20-4mA Keypad ModbusRTU BACnet Optional drive.web Ethernet distributed control + programmable control, extra i/o, operator stations drive.web, ModbusTCP, EIP, DeviceNet, Profibus 24VDC, 100mA short protected 10VDC, 5mA for setpoint potentiometer 3 x Digital 10 to 30 VDC, response <4ms 2 x Analog/digital 2 x Analog, 0-10V, 0-20mA, 4-20mA 2 x Relay NO, 6A @ 250VAC, 5A @ 30VDC Internal PID with feedback display Last 4 trips stored with time stamp Current, temperature, DC Bus volts prior to trip Service life monitor with user adjustable interval Hours run Resettable and non-resettable kWh meters Fire mode for emergency ventilation Pump blockage detection Pump cleaning cycles Multi-pump cascade control Pump stir mode
200-240V 10%, 3-ph in, 230V, 3-ph motor Model HP Amps Size NEMA
sizes 2 & 3 with EMC Filter: ODV2-22010-3HF1X 1 4.3 ODV2-22020-3HF1X 2 7 ODV2-22030-3HF1X 3 10.5 ODV2-32050-3HF1X 5 18 sizes 4-7 with EMC filter & DC choke: ODV2-42075-3HF1N 7.5 24 ODV2-42100-3HF1N 10 30 ODV2-42150-3HF1N 15 46 ODV2-52020-3HF1N 20 61 ODV2-52025-3HF1N 25 72 ODV2-52030-3HF1N 30 90 ODV2-62040-3HF1N 40 110 ODV2-62050-3HF1N 50 150 ODV2-62060-3HF1N 60 180 ODV2-62075-3HF1N 75 202 ODV2-72100-3HF1N 100 248 ODV2-72120-3HF1N 120 312 2 2 2 3 4 4 4 5 5 5 6 6 6 6 7 7 4X 4X 4X 4X 12 12 12 12 12 12 12 12 12 12 12 12
Ambient Ratings
380-480V 10%, 3-ph in, 460V, 3-ph motor Model HP Amps Size NEMA
sizes 2 & 3 with EMC Filter: ODV2-24010-3HF1X 1 2.2 ODV2-24020-3HF1X 2 4.1 ODV2-24030-3HF1X 3 5.8 ODV2-24050-3HF1X 5 9.5 ODV2-34075-3HF1X 7.5 14 ODV2-34100-3HF1X 10 18 sizes 4-7 with EMC filter & DC choke: ODV2-44150-3HF1N 15 24 ODV2-44200-3HF1N 20 30 ODV2-44250-3HF1N 25 39 ODV2-44300-3HF1N 30 46 ODV2-54040-3HF1N 40 61 ODV2-54050-3HF1N 50 72 ODV2-54060-3HF1N 60 90 ODV2-64075-3HF1N 75 110 ODV2-64120-3HF1N 120 150 ODV2-64150-3HF1N 150 180 ODV2-64175-3HF1N 175 202 ODV2-74200-3HF1N 200 240 ODV2-74250-3HF1N 250 302 size 8 with EMC filter & line choke: ODV2-84300-3HF14 300 370 ODV2-84300-3HF14 350 450 2 2 2 2 3 3 4 4 4 4 5 5 5 6 6 6 6 7 7 8 8 4X 4X 4X 4X 4X 4X 12 12 12 12 12 12 12 12 12 12 12 12 12 1 1
Application functions Dimensions Size Height (ins) Height (mm) Width (ins) Width (mm) Depth (ins) Depth (mm)
Stop Mode Braking Skip Frequency Analog Setpoint Control Digital Setpoint Control
Automation Communications Options I/O Specification Power Supply Programmable Inputs Programmable outputs
Bardac.com
29
OPTIDRIVE E2
General purpose drives with all purpose features Up to 15 HP Basic or NEMA 4X (IP66) Basic or full featured systems drive 3-Phase & single phase motor versions
Basic or loaded, the new E2 is designed to give you the very best in value, performance and ease of use. The innovative design incorporates flexibility, expandability and convenience that will work in many different applications throughout your plant.
AC drives
Compact packaging Simple mechanical and electrical installation 50C ambient rating 150% rating for 60 seconds, 175% for 2 seconds Simple 14 parameter basic set up Integral RFI filter option Integral brake transistor, sizes 2 & 3 (100% continuous rated) ModbusRTU serial port
Options: Remote keypad and display OPTISTICK plug in unit for fast up/down load of parameters smarty remote i/o, programmable control & Ethernet networking speedy programmable control & Ethernet networking savvyPanel smart touch screen operator station technology
Models in blue are stocked in limited quantities Please call +410-604-3400 for availability DIMENSIONS & WEIGHT Size Height Width 1 6.8 (173mm) 3.3 (82mm) 2 8.7 (221mm) 4.1 (104mm) 3 10.3 (261mm) 5.2 (131mm) Depth 4.9 (123mm) 5.9 (150mm) 6.9 (175mm) Weight 2.5lbs (1.1kg) 5.9lbs (2.6kg) 9lbs (4.0kg)
30
Environment
Temperature Altitude Humidity Ingress Protection Control Mode PWM frequency V/Hz ratio Boost Stop modes Skip frequency Setpoint reference Preset speeds PI control Spin start Accel/Decel Configurable i/o Input 1 Input 2 Input 3 Input 4 Output 1 Output 2 Protection Drive trip Motor Trip memory
0 to 500Hz 48 - 62 Hz 100 - 132 volts max, single phase (0.5 - 1.5HP) 180 - 264 volts max, 1-phase (0.5 - 3HP) 180 - 264 volts max, 3-phase (0.5 - 5HP) 342 - 528 volts max, 3-phase (1 - 15HP) Operating, -10 to 50C max, storage, -40 to 60C 0-2000M, derate 1% per 100M above 1000M up to 95%, non condensing Basic IP20, Optional IP55 (NEMA12) Voltage vector 4 to 32KHz (effective) Linear Yes Coast / ramp / DC brake One point, adjustable frequency band 0-10VDC, 4-20mA, 20-4mA, 0-20mA, Keypad, Modbus 8 Direct & analog input trim Starts safely into rotating motor 0 - 600 seconds + Ramp stop decel 0 - 600 seconds Programmable digital input Programmable digital input Configurable analog or digital input Configurable analog or digital input Configurable analog or digital output Normally open relay contact 30VDC 5A, 250VAC 6A Over/under volts, over current, external trip, Overload, over temperature, short circuit, ground fault Last 4 trips stored
drive.web smart automation powerful programmable control functions peer-to-peer over Ethernet smart iPad or touch screen PC operation Internet access
DIMENSIONS & WEIGHT Size Height Width 1 7.9 (200mm) 5.5 (140mm) 2 12.2 (310mm) 6.5 (164mm) 3 12.2 (310mm) 8.3 (211mm)
Bardac.com
31
AC drives
Embed a speedy in the drive to provide Ethernet networking & programmable control
ODE2-32050-3H04Y
# X = Unswitched, Y = Switched
32
AC Drive Options
ITEM Remote Keypads OD-OPRTP-US OPT2-OPORT-IN DESCRIPTION Remote keypad Remote Keypad MODEL P P2 V2 E2 P P P P
Communications Options speedy dw21X-04 ModbusTCP/IP Interface Module speedy dw21X-25 EIP/PCCC Interface Module OPT2-DEVNT-IN DeviceNet Interface Module OPT2-PROFB-IN Profibus DP Interface Module Programming Interface Options speedy dw21X USB Interface Module OPT-STICK-IN Optistick parameter copying stick with IR interface OPT2-STICK-IN Optistick parameter copying stick with Bluetooth Encoder Feedback Options ODP-ENCOD-US Encoder feedback unit, DIN rail mounting OPTION-RTX Encoder pulse buffered retransmit OPT2-ENCOD-IN Encoder feedback module for P2 EMC Filters OD-F1121-US OD-F2121-US OD-F1341-US OD-F2341-US OD-F3341-US Optifilter, drive size 1, 230V, 1-phase Optifilter, drive size 2, 230V, 1-phase Optifilter, drive size 1, 230/480V, 3-phase Optifilter, drive size 2, 230/480V, 3-phase Optifilter, drive size 3, 230/480V, 3-phase
INTERNET
P P P P P P P P
P P P
P P P P P P P P P P P P P P P P P P
Brake Resistors (Case Type) OD-BR100-IN DB Resistor, drive size 2, 100, 200W OD-BR050-IN-i55 DB Resistor, drive size 2, IP55 50, 200W OD-BRES4-IN DB Resistor, drive size 4, 33, 500W Brake Resistors (Enclosed, ventilated with over temp switch) Intermittent duty 10%, 10 sec CX503069 1 - 3 HP 230VAC, 63, 12x5x5 CX503070 5 HP 230VAC, 38, 12x5x5 CX503072 7.5 - 10 HP 230VAC, 19, 12x7x5 CX503073 15 HP 230VAC, 12.6, 12x10x5 CX503074 20 HP 230VAC, 9.6, 12x13x5 CX503075 25 HP 230VAC, 7.5, 12x16x5 CX503076 30 HP 230VAC, 6.3, 19x10x5 CX503077 40 HP 230VAC, 4.9, 19x10x5 CX503078 50 HP 230VAC, 3.9, 19x10x5 CX503079 30 HP 230VAC, 3.3, 19x13x5 CX503082 CX503085 CX503086 CX503087 CX503088 CX503089 CX503090 CX503091 CX503092 CX503093 CX503094 CX503096 Input Line Reactors OD-IL121-US OD-IL221-US OD-IL143-US OD-IL243-US OD-IL343-US Output Filters OD-OUTF1-US OD-OUTF2-US OD-OUTF3-US OD-OUTF4-US OD-OUTF5-US OD-OUTF6-US DIN Rail Mounts OD-DINPL-01 OD-DINPL-02 1 - 3 HP 460VAC, 250, 12x5x5 5 - 10 HP 460VAC, 75, 12x7x5 15 HP 460VAC, 50, 12x10x5 20 HP 460VAC, 38, 12x13x5 25 HP 460VAC, 30, 12x16x5 30 HP 460VAC, 25, 19x10x5 40 HP 460VAC, 19, 19x13x5 50 HP 460VAC, 15, 19x13x5 60 HP 460VAC, 12.6, 19x13x5 75 HP 460VAC, 10, 26.5x10x5 100 HP 460VAC, 7.5, 26.5x16x5 125 - 150 HP 460VAC, 6, 28x10x10 Input inductor, drive size 1, 220/240V, 1-ph, 10A Input inductor, drive size 2, 220/240V, 1-ph, 25A Input inductor, drive size 1, 380/480V, 3-ph, 6A Input inductor, drive size 2, 380/480V, 3-ph, 10A Input inductor, drive size 3, 380/480V, 3-ph, 36A Output sine filter, drive size 1, 480V, 10A Output sine filter, drive size 2, 480V, 12A Output sine filter, drive size 3, 480V, 30A Output sine filter, drive size 4, 480V, 75A Output sine filter, drive size 5, 480V, 180A Output sine filter, drive size 6, 480V, 250A DIN rail mount kit for drive size 1 DIN rail mount kit for drive size 2
P P P P P
P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P
Add a drive.web module to any drive for unlimited automation capability: Powerful programmable control functions Peer-to-peer networking over Ethernet Smart iPad or touch screen PC operation Internet access
ITEM DESCRIPTION Smart Programmable Control + Peer-to-Peer Networking + Extra i/o dw212 drive.web smarty interface for E2 models w/16 extra i/o dw213 drive.web smarty interface for ODP models w/16 extra i/o dw214 drive.web smarty interface for P2 models w/16 extra i/o dw216 drive.web smarty interface for V2 models w/16 extra i/o -04 OPTION ModbusTCP/IP -05 OPTION Function Block Library 1, Process Control -06 OPTION Function Block Library 2, Winder Control -10 OPTION Function Block Library 3, Advanced Math -15 OPTION Encoder input For additional options see page14 MODEL P P2 V2 E2 P P P P P P P P P P P P P P P P P P P P P P P
P P P P P P P P P P P P P P P P P P
Smart Programmable Control + Peer-to-Peer Networking dw22X drive.web speedy interface modules P P P P With Ethernet ModbusTCP/IP & basic function blocks - see page 14 -05 OPTION Function Block Library 1, Process Control P P P P -06 OPTION Function Block Library 2, Winder Control P P -10 OPTION Function Block Library 3, Advanced Math P P P P
P P P P P P P P P P P P P P P P P P P
P P
Data Cables & Splitters OD-48503-US RS485 data cable, 0.3M, (RJ11 - RJ11) OD-48510-US RS485 data cable, 1M, (RJ11 - RJ11) OD-48530-US RS485 data cable, 3M, (RJ11 - RJ11) OPT-J4505-IN RS485 data cable, 0.5M, (RJ45 - RJ45) OPT-J4510-IN RS485 data cable, 1M, (RJ45 - RJ45) OPT-J4530-IN RS485 data cable, 3M, (RJ45 - RJ45) OD-485SP-US RS485 data cable 3-way splitter (RJ11) OPT-J45SP-IN RS485 data cable 3-way splitter (RJ45) i/o Boards OPT-LOGIP-11 OPT-LOGIP-23 ODP-3ROUT-US 110VAC logic input isolator 230VAC logic input isolator 3-Relay output board
P P P P P P P P P P P P P P P P
P P P P P P
Bardac.com
33
AC drives
OPTIDRIVE E2 SP
For Shaded Pole (SP) & Permanent Split Capacitor (PSC) motors used in variable torque, fan and pump type applications only
Basic or NEMA12 versions Basic or full featured systems drive Basic or peer-to-peer networking over Ethernet
SPECIFICATION Output Frequency Supply options Frequency Volts/Phases Environment Temperature Altitude Humidity Ingress Control Mode PWM Hz V/Hz ratio Boost Stop modes Setpoint ref Presets PI control Accel/Decel Configurable i/o Input 1 Input/output 2 Input 3 Input 4 Output 1 Relay 1 Protection Drive trip Motor Trip memory 0 to 500Hz 48 - 62 Hz 100 - 132 volts max, single phase (0.5 - 1.0HP) 180 - 264 volts max, 1-phase (0.5 - 1.5HP) 180 - 264 volts max, 3-phase (0.5 - 1.5HP, special order) Operating, -10 to 50C max, storage, -40 to 60C 0-2000M, derate 1% per 100M above 1000M up to 95%, non condensing Basic IP20, Optional IP55 (NEMA12) V/F 4 to 32KHz (effective) Linear Automatic boost phase operation Coast / ramp / DC brake 0-10VDC, 4-20mA, 0-20mA, Keypad, Modbus 8 preset speeds Direct & analog input trim 0 - 600 secs + Ramp stop decel 0 - 600 secs Programmable digital input Selectable digital input / output Configurable analog or digital input Configurable analog or digital input Configurable analog or digital output Normally open relay contact 30VDC 5A, 250VAC 6A Over/under volts, over current, external trip, Overload, over temp, short circuit, ground fault Last 4 trips stored
THE BASICS Compact packaging Simple mechanical and electrical installation 50C ambient rating 150% rating for 60 seconds, 175% for 2 seconds Simple basic set up Integral brake transistor (size 2, 100% rated) ModbusRTU serial port Remote keypad and display option OPTISTICK plug-in for easy parameter up/down load
34
Power
0.5HP 0.75HP 0.5HP 1HP 1.5HP
Amps
7.0 10.5 4.3 7.0 10.5
Size
1 2 1 1 2
ODE2-11005-1H012-01 1, 115V ODE2-21007-1H042-01 1, 115V ODE2-12005-1H012-01 1, 230V ODE2-12010-1H012-01 1, 230V ODE2-22015-1H042-01 1, 230V
DIMENSIONS & WEIGHT Size Height Width Depth Weight 1 6.8 (173mm) 3.3 (82mm) 4.9 (123mm) 2.5lbs (1.1kg) 2 8.7 (221mm) 4.1 (104mm) 5.9 (150mm) 5.9lbs (2.6kg)
E2 SP NEMA 12 / IP55
Single phase motor controller for use only with Shaded Pole (SP) or Permanent Split Capacitor (PSC) type motors in variable torque, fan and centrifugal pump applications
Switched version with keypad, display, speed pot, forward/off switch & power isolator switch Unswitched version with keypad & display
40C ambient temperature Conduit cable entry Padlockable power switch Wash down duty ModbusRTU port
Compact packaging All standard drive features included Brake standard on 230V, size 2 Optional internal Ethernet Optional internal drive.web
Power
0.5HP 0.75HP 0.5HP 1HP 1.5HP
Amps
7.0 10.5 4.3 7.0 10.5
Size
1 2 1 1 2
ODE2-11005-1H01#-01 1, 115V ODE2-21007-1H04#-01 1, 115V ODE2-12005-1H01#-01 1, 230V ODE2-12010-1H01#-01 1, 230V ODE2-22015-1H04#-01 1, 230V
# N = Unswitched, S = Switched DIMENSIONS & WEIGHT Size Height Width Depth Weight 1 7.9 (200mm) 5.5 (140mm) 6.4 (162mm) 5.4lbs (2.4kg) 2 12.2 (310mm) 6.5 (164mm) 6.9 (176mm) 10.3lbs (4.6kg)
Bardac.com
35
DC technology
MODEL RATING
NON-ISOLATED K340 Armature current 3.4 amps 1/4Hp 0.25kW @90Vdc 1/2Hp 0.55kW @180Vdc Size 1.4W x 4.2H x 4.7D K680 Armature current 6.8 amps 1/2Hp 0.55kW @90Vdc 1Hp 0.75kW @180Vdc Size 1.8W x 4.2H x 4.7D Armature current 12.2 amps 1Hp 0.75kW @90Vdc 2Hp 1.8kW @180Vdc Size 1.8W x 4.2H x 4.7D
FEATURES
TERMINALS
K1220
Max Speed +10V Min Speed Min Up Ramp Input + IR Comp Common I max Run AVF/Tach switch Tach f/b Speed range switch AC voltage selector Field 1Amp 0.9x ac supply
ISOLATED K340i Armature current 3.4 amps 1/4Hp 0.25kW @90Vdc 1/2Hp 0.55kW @180Vdc Size 2.4W x 4.2H x 4.7D K680i
K1220i
Max Speed Min Speed Up Ramp Down Ramp Armature current 6.8 amps Stability 1/2Hp 0.55kW @90Vdc I max 1Hp 0.75kW @180Vdc IR Comp Size 2.8W x 4.2H x 4.7D AVF/Tach switch Speed range switch Armature current 12.2 amps AC voltage selector 1Hp 0.75kW @90Vdc Level comparator 2Hp 1.8kW @180Vdc Size 2.8W x 4.2H x 4.7D
+10V ref Min speed Input + Output +/Common Input +/Pushbutton + Pushbutton Run Common Tach f/b
LevelO/P Level iI/P Overload Trip Ramp O/P Demand O/P Speed O/P Current O/P + Speed I/P Torque I/P
Optional drive.web smarty For complete process automation Model dw210-1107 uses discrete i/o interface to provide: Ethernet networking Internet access Powerful function blockprogramming ModbusRTU and ModbusTCP/IP Additional remote i/o Encoder feedback (see page 20 for details)
4-QUADRANT, REGENERATIVE, REVERSING, ISOLATED K340XRi Armature current 3.4 amps 1/4Hp 0.25kW @90Vdc Max Speed 1/2Hp 0.55kW @180Vdc Min Speed Size 2.4W x 4.2H x 4.7D Up Ramp Down Ramp K680XRi Armature current 6.8 amps Stability 1/2Hp 0.55kW @90Vdc I max 1Hp 0.75kW @180Vdc IR Comp Size 2.8W x 4.2H x 4.7D AVF/Tach switch Speed range switch K1220XRi Armature current 12.2 amps AC voltage selector 1Hp 0.75kW @90Vdc Level comparator 2Hp 1.8kW @180Vdc Size 2.8W x 4.2H x 4.7D
+10V ref Min speed Input + Output +/Common Input +/Pushbutton + Pushbutton Run Common Tach f/b
LevelO/P Level iI/P Overload Trip Ramp O/P Demand O/P Speed O/P Current O/P + Speed I/P Torque I/P
High Speed Fuse Kits - DIN Rail Mounting FLN-6.3 Line fuse kit K340 FLL-6.3 Line/line fuse kit K340 FLNR-6.3 Line & arm fuse kit K340XRi FLLR-6.3 Line/line & arm fuse kit K340XRi FLN-20 Line fuse kit all non-regen K FLL-20 Line/line fuse kit all non-regen K FLNR-20 Line & arm fuse kit all regen K FLLR-20 Line/line & arm fuse kit all regen K
36
This family of single phase DC drives with isolated control circuitry, is designed to meet the most exacting requirements of high performance systems builders. It is a range of full featured products using advanced manufacturing technologies to give unequaled value and functionality to OEMs and System Integrators with world wide markets and demanding applications. FUSE KIT
included F2-30 F2-60 F2-80 F2-60
FUSE KIT
F3-30 F3-60 F3-60 F3-60 F3-60
Standard Features
Approvals: CE Linear torque control Armature voltage or tach feedback Calibration range switches Speed reference 0-10V or 4-20mA Maximum and minimum speed settings Adjustable current limit Current range switch selectable (not on 400i) Independently adjustable up and down ramps 150% overload capacity, 30 second stall timer Stall relay contact output (transistor on 400i) Zero speed relay contact (transistor on 400i) Control fuses fitted (Power fuse on 400i) Start inhibit after power loss Power on and stall indicator LEDs Speed signal output Current signal output Ramp signal output Total demand signal output Dual supply voltage 110 / 230 VAC, 50/60Hz Suitable for shunt or PM motors IR compensation Stability adjustment
For complete process automation Model dw210-1107 uses discrete i/o interface to the drive and to provide: Ethernet networking Internet access Powerful function blockprogramming ModbusRTU and ModbusTCP/IP Additional remote i/o Encoder feedback (see page 15 for details)
Model 3200i, up to 7.5hp 6.1 x 8.0 x 4.2 (150 x 200 x 105 mm)
Speed reference +/-10V or 4-20mA Speed trim input Independent up & down ramps in FWD & REV Separate adjustable current limits motor/brake Torque control in either 2 or 4 quadrants Relay for Stall, Zero speed, Reverse, Overload Control fuses fitted Fast, ramped or coast stop LEDs for + current, - current, stall & stall timer Momentary contact for reversing applications
Enclosed Drives
Enclosed wall mounting versions of these drives and a wide range of other options are detailed in the Modulus Drive Units section of this catalog Model 3600XRi Up to 32 amps - 6.9x 8x 3.2 (175x200x80 mm) 36 amps unit - 6.9x 8x 3.8 (175x200x95 mm)
Bardac.com
37
DC technology
Single Phase DC Drives for OEMs
Model 370 ... OEM Chassis Drives
Basic Specification: Compact, DC drives designed for low cost, non-regenerative, non-isolated machine controls.
Rating: 1/4hp at 90VDC, 1/2hp at 180VDC Maximum and minimum speed settings Current limit Acceleration pot Suitable 110 or 230 volts, single phase, 50 or 60Hz (not isolated) For use with permanent magnet or shunt field motors Approval: CE Dimensions 4 x 4 x 1.6 (100 x 100 x 40mm)
Amps
4 amps 8 amps 12 amps 4 amps 8 amps 12 amps
Description
Open chassis with screw terminals Open chassis with screw terminals Open chassis with screw terminals Enclosed NEMA 1 with pot, switch, fuse Enclosed NEMA 1 with pot, switch, fuse Enclosed NEMA 1 with pot, switch, fuse Enclosed, pot, switch, brake, reverse, fuse Enclosed, pot, switch, brake, reverse, fuse Enclosed, pot, switch, brake, reverse, fuse
@ 180VDC
0.75hp 1.5hp 2.0hp 0.75hp 1.5hp 2.0hp 0.75hp 1.5hp 2.0hp
@ 90VDC Dimensions
0.38hp 0.75hp 1.0hp 0.38hp 0.75hp 1.0hp 0.38hp 0.75hp 1.0hp 5.2x4.0x1.6 (130x100x40mm) 5.2x4.0x2.8 (130x100x70mm) 5.2x4.0x2.8 (130x100x70mm) 9.9x7.0x3.8 (250x177x95 mm 9.9x7.0x3.8 (250x177x95 mm 9.9x7.0x3.8 (250x177x95 mm 9.9x7.0x3.8 (250x177x95 mm) 9.9x7.0x3.8 (250x177x95 mm) 9.9x7.0x3.8 (250x177x95 mm)
Standard features:
Linear torque control Armature voltage or tach feedback with IR compensation Calibration range switches (no component changes) Speed reference 0-10V or 4-20mA Maximum and minimum speed settings Adjustable current limit Independently adjustable up and down ramps 150% overload capacity with 30 second stall timer Stall and Zero Speed relay driver outputs Power fuse (up to 12 amps) Power on and stall indicator LEDs Stability adjustment Speed, Ramp Speed and Current signal outputs International supply voltages 110 / 230 VAC, 50/60hz (not isolated) Suitable for shunt wound or permanent magnet motors
Approvals: CE
Model 1200E
38
Each unit incorporates facilities for implementing optional control modes with either P or P+I or PID (Proportional, Integral, Derivative) to enable optimum high performance in a wide variety of applications. Optional configurations: 1. Speed control, armature voltage feedback with IR compensation. 2. Speed control, tach feedback. 3. Position control, position feedback. 4. Torque control with armature current feedback.
Standard Features
Speed, Position, or Torque control modes Extremely low RF noise emissions Ready indicator light Motor voltage range: +/-6 VDC to +/-48 VDC Armature current up to 2A cont., 3A peak Supply voltage 12 to 48 VDC Precision 5v and 10v references (short circuit protected, 5mA) Differential setpoint inputs (300K ohms) Overload trip Thermal protection Adjustable Maximum Speed Adjustable IR Compensation for armature volts feedback Plug-on terminals DIN rail mounting clip (optional)
Dimensions
Approvals: CE
Bardac.com
39
DC technology
up to 2000+ hp
PL/X145 Up to 200 HP
PL/X50 Up to 75 HP
Standard Features
Total digital control Basic peer-to-peer link 40 character backlit display Friendly, easy menu structure Modern, compact packaging Extensive, flexible, plug-in i/o RS232 serial port Easy configuration saving & cloning Built-in automatic field controller Built in programmable control functions for PID, winders, orientation, etc. Tach, encoder & arm volts feedback Easy reliable autotune UL, C-UL, CE
PL/X440 Up to 900 HP
Optional:
Peer-to-peer Ethernet communications drive.web programmable control ModbusTCP & EIP over Ethernet ModbusRTU RS485 serial port Devicenet Profibus DP
powerDRIVE Packages
PL/X DC drives up to 400 horsepower are available in compact powerDRIVE packages complete with: Main contactor High speed 3-phase line fuses High speed armature fuse High speed control/field fuses Line filter (100HP & up) Optional motor blower starter (100HP & up)
40
Key Features
Analog Inputs & Outputs 8 analog inputs & 4 analog outputs (12 bits) All outputs short circuit protected All inputs over voltage protected up to +50v Inputs configurable 5 to 30v Input volts programmable up to +/-30v Digital Inputs & Outputs 17 digital inputs & 7 digital outputs Digital i/o short circuit protected Digital inputs over volts protected to +50v (with settable switching levels) Digital outputs over volts protected to +50v Speed Feedback - Standard Analog tach Encoder Armature voltage Encoder + armature volts Encoder + analog tach Field Configurations Fixed Current Fixed voltage Automatic field weakening Delayed field quench Standby field setting Field economy Diagnostic Monitoring Scope terminal monitors selectable values All analog input voltages All digital input states All analog output voltages All digital output states Tach volts Motor arm volts & amps Field current Output power Kw AC supply volts User Configurable Software Functions Two PID blocks, Parameter profiler, Winder reel diameter calculator, Winder taper tension calculator, Winder torque/inertia/ friction compensator, Preset speed function, Two summers, Software motorized pot, Interval timer, Current profiling, Zero speed with shaft position lock, Jog / crawl functions, Two filters, Dual motor swap, Latch, Sample & hold function, Auto self-tune current loop, Linear and S-ramps, Slack take-up, Batch Counter, Draw control. Engineered Configuration Packages Using the drive.web speedy dw111 controller, pre-configured generic apps are available for Open & Closed Loop Winders, Position Controls, Coordinated Line Drives, Indexing and others. Protection Interline device networks High energy MOVs Instantaneous overcurrent Overcurrent ( inverse time) Field fail and overcurrent Motor over temperature SCR (thyristor) over temp Main power phase loss Armature over volts Over speed protection Speed feedback mismatch Stall protection Standstill logic SCR (Thyristor) trigger failure Digital output short circuit RS232 Serial Communications Port Parameter upload/download to save and print Drive - to - drive parameter link & set up cloning Optional Communications drive.web peer-to-peer Ethernet: drive.web, ModbusTCP/IP, EIP ModbusRTU Profibus DP
Easily add a savvyPanel touch screen HMI with secure WiFi interface
Simple, intuitive configuration techniques with clear display of information No pots or switches to set Accurate display of voltages and currents Positive displacement pushbuttons for tactile feel High power processor and large memory will ensure ease of product enhancement in the future 2-button reset gets users back to OEM set up Powerful savvy graphical configuration, diagnostics & system design tools
Bright, 40 character display with clear parameter descriptions exit menu level scroll down
The powerful savvy configuration tools are used for the PL Series DC drives, AC drives, drive.web programmable controllers, savvyPanel operator stations & complete systems.
Bardac.com
41
DC technology
PLX185/430 8.5 x 19.9 x 11.6 (43) PLX225/530 8.5 x 19.9 x 11.6 (45)
powerDRIVE Model
Dimensions W x H x D (weight) inches (LBS) 8.5 x 11.4 x 11.7 (26) 8.5 x 11.4 x 11.7 (26) 8.5 x 11.4 x 11.7 (30) 8.5 x 11.4 x 11.7 (30) 16 x 33 x 9.7 (80) 16 x 33 x 9.7 (80) 16 x 33 x 9.7 (82) 16 x 33 x 9.7 (89) 16 x 43.5 x 13.7 (143) 16 x 43.5 x 13.7 (143) 16 x 43.5 x 13.7 (154)
basicDRIVE Model PL15/36 PL20/51 PL40/99 PL50/123 PL65/164 PL85/205 PL115/270 PL145/330 PL185/430 PL225/530 PL265/630
Dimensions W x H x D (weight) inches (LBS) 8.5 x 11.4 x 6.9 (16) 8.5 x 11.4 x 6.9 (16) 8.5 x 11.4 x 6.9 (17) 8.5 x 11.4 x 6.9 (17) 8.5 x 16.2 x 8.6 (27) 8.5 x 16.2 x 8.6 (27) 8.5 x 16.2 x 8.6 (28) 8.5 x 16.2 x 8.6 (28) 8.5 x 19.9 x 11.6 (43) 8.5 x 19.9 x 11.6 (45) 8.5 x 19.9 x 11.6 (45)
Line Reactor Model LM37 LM52 LM120 LM120 LM150 LM195 LM240 LM300 LM375 LM480 LM600
powerPL15/36 powerPL20/51 powerPL40/99 powerPL50/123 powerPL65/164 powerPL85/205 powerPL115/270 powerPL145/330 powerPL185/405 powerPL225/480 powerPL265/630
basicDRIVES must be installed with new contactor and the correct high speed SCR fuses to maintain the warranty drive.web options see pages 84 - 89 Computer RS232 Communications Cable - Drive to DB9 - part number LA102595, included with every drive For details of Drive Isolation Transformers, Line Reactors and Line Filters, please see pages 78 - 79
42
Bardac.com
43
DC technology
PLXD Separate Stack Controller
The PLXD is a great retrofit option for controlling large separate SCR stacks in either 6 or 12-pulse DC drive configurations and also for wound rotor motor SCR stack control. The unit has all the standard PL/X series drive features together with: Available for stacks up to 690 volts AC, 700 volts DC Built-in 32 amps fully automatic field controller (optional 50 amps rating) Separate gate pulse driver unit for greater noise immunity and reliability Optional current transformers Optional Ethernet and drive.web distributed control Please call for details
INTERNET
Add a drive.web module to any drive for unlimited automation capability: Powerful programmable control functions Peer-to-peer networking over Ethernet Smart iPad or touch screen PC operation Internet access smarty - adds programmable control & extra i/o speedy - adds programmable control & gateway Get clear graphical signal flow system diagrams. Send event driven emails from your drive. All in one unique, intuitive, environment.
drive.web automation Intuitive Easy Reliable Very smart!
Import or export data Monitor trend charts Change the configuration Make drag & drop connections Manage multiple drives at the same time
44
Standard Features
SL SLX SLE Field controller with automatic field weakening Configurable field bridge Heat sink thermostat protection Diagnostic test socket 50/60Hz autoranging Power supply range: 208-240 or 380-480 volts +/-10% Auxiliary control power input: 115 volts 50/60Hz. Phase rotation insensitivity Linear torque control Armature voltage or tach feedback Calibration range switches (no component change) Speed reference +/-10V or 4-20mA Speed trim input Maximum and minimum speed settings Adjustable up & down ramps Adjustable current limit Current range selectable for multiple horsepowers Torque control 150% overload capacity with 30 second stall timer Relay outputs: Stall, Zero speed, Overload Regen stop (SLX 4-quad. regen drive) Setpoint ramp reset Start inhibit after power loss LED indicators: Stall Stall Timer +/- Current Field Loss Tach Loss Peak Amps Ext. Trip Power On 25%, 50%, 95% Field Volts Speed signal output Current signal output Ramp & Total demand signal outputs Shunt wound or permanent magnet motors Stability adjustment Current reduction for low power test
Control fuses 3-Phase high speed semiconductor fuses Armature high speed semiconductor fuse Main AC line contactor
basicDRIVE 500VDC 240VDC Armature Line reactor Drive Isolation Model Arm Arm Current Transformer SLE14 20hp 10hp 34 amps LM37 DIT27** SLE24 30hp 15hp 58 amps LM52 DIT40** SLE34 50hp 20hp 82 amps LM82 DIT63** SLE34 60hp 30hp 106 amps LM120 DIT75** Field current up to 2.5 amps Dimensions: basicDRIVE 11.5 high x 8.5 wide x 6.1 deep (290mm x 215mm x 155mm) Dimensions: powerDRIVE 11.5 high x 8.5 wide x 9.4 deep (290mm x 215mm x 240mm)
Mount Holes HxW 2.1x2.0 2.3x3.0 2.6x3.0 3.2x3.0 3.2x3.0 3.5x3.6 3.5x3.6 3.2x3.0 3.2x3.6 4.2x3.6 4.2x3.6 5.9x4.6 6.8x4.6 6.8x4.6 9.3x4.6 9.5x7.2
Options Outdoor enclosures Frequencies other than 60Hz Voltages other than 230/460/575 pri, 230/460 sec Special Taps Fungus Proofing 80C & 115C Rise Copper Windings Electrostatic Shield K-13, K-20, K-30 Discount Schedule SX-1
Bardac.com
45
Every Modulus project is accompanied by a detailed, 50-point, Quality Control Report covering every facet of the product, its design, construction, testing and shipping.
Using innovative, interactive, Internet online technologies we can provide either product training or product support through your browser from the comfort of your desk! Simply connect via your browser and get live interactive support where ever you are - with savvy running on your computer call +410-604-3400 and in less than a minute an engineer will be able to see your system live and give you the support you need. ... its as easy as that!
Internet
Unbeatable!
46
Online Training
Online product training courses are scheduled every week with options for users of all levels of interest and ability. Sessions are completely interactive with the presenter as if you were in the same room. Level 1 - drive.web introductory seminar - 11/2 hours - Free! This provides an overview of the drive.web automation technology. Learn how to connect to drives, create drive phantoms, navigate systems, create signal flow diagrams and system drawings, find information, identify object attributes, make connections, show trend charts, build savvyPanel operator stations, etc. Level 2 - drive.web design technology course - 3 hours (Level 1 is a prerequisite) Covers configuration of drives, basic system design concepts, Ethernet networking, password protection, system safety Level 3 - drive.web system design and application courses (Level 2 is a prerequisite) 3a) Drive and device interfaces - 2 hours Covers the use of Templates and Helpers for documented drives, generic ModbusRTU master interfaces to third party drives, operator stations, etc. 3b) Winder Control Systems - 3 hours Covers standard solutions for open loop CTCW winders, closed loop dancer controlled winders and closed loop loadcell controlled winders. 3c) Encoder Control Systems - 3 hours Covers applications such as electronic line shaft, spindle orientation, registration and position control. 3d) Advanced Ethernet, Internet Access and Security - 3 hours Covers local and wide area network configuration, IP addressing, user access and device and system password protection. For course details, registration, international training options and charges please call us at 1-888-667-7333 (toll free USA 888-ON SPEED) or international at +410-604-3400. Alternatively please contact [email protected]
Field Service, Service Center Repair, Training and Start-up - Call +410-604-3400 Rates for the Continental United States
Charge Basis Rates (US$) a. Basic Rate - Field Service, Training & Start-up Assistance - up to 8 hours daily Monday to Friday, 7am to 6pm $150 per hour b. Standard Overtime - Weekdays 6pm to 7am & all day Saturday - Total work time not to exceed 12 hrs in any 24 hrs $225 per hour c. Special Overtime - Sundays, Holidays and excess of 8 hours on Saturday $300 per hour d. Overnight - Includes meals, and hotel accommodation $225 per night e. Auto Travel - Covering cost of use of company or personal cars, distance to and from the local office $0.55 per mile f. Public Transport - Rental cars, Air fares, etc. At Cost g. Holdover & Standby Time Same as service h. Travel Time - Time taken from Bardac to job site and return Same as service i. Basic Rate - Service Center Repair charges - Diagnosis & repair time $95 per hour + parts j. Design or application engineering services $150 per hour Notes: 1. Minimum service billing is 4 hours for field services, 1 hour for service center services. 2. Parts, materials, special visas, duties, and extraordinary expenses will be charged extra. 3. Warranty credits will be identified on the Daily Field Service Report.
For rates and availability of sales and service outside the US, please call +410-604-3400
During normal business hours basic tech support will be provided free of charge Outside normal business hours call +410-604-3535. Tech support will be provided at $300/hour (minimum of 1/2 hour per call) and this must be paid for with a credit card at the time of service.
Bardac.com
47
Bardac Corporation
E Electronic Line Shaft 19 Email Function Block 21 Engineered Apps 15 F Field Service 47 Flux Vector Drives 22, 24, 26 G General Purpose VFDs 30, 32 H HVAC drives 28 I iOS, iPad, iPhone savvyPanel 11
40 Log Canoe Circle Stevensville, MD 21666 USA www.bardac.com www.driveweb.com Phone International +410-604-3400 Phone US Toll Free 1-888-667-7333 1-888-ON SPEED Fax +410-604-3500 Catalog 2012.1