EXAMINATION REPORT OF

LIFT
UAIL(RIFINARY)
LIFT (SEC-28) TESTING LIST FY/2024-25
SL ITEM CAPACITY MAKE LOCATION EQP ID CERTIFICATE NUMBER TEST DATE DUE DATE

1 LIFT FOR DIGESTERS 544 MT THYSSEN KRUPP DIGESTION LF234-101 UEC/UAIL/REF/LIFT/2024/22 14-08-2024 13-02-2025
LIFT FOR FILTER SECURITY
2 544 MT THYSSEN KRUPP LF250-101 UEC/UAIL/REF/LIFT/2024/23 14-08-2024 13-02-2025
BUILDING FILTRATION
LIFT FOR
3 1.5 MT THYSSEN KRUPP PRECIPITATION LF332-101 UEC/UAIL/REF/LIFT/2024/24 14-08-2024 13-02-2025
PRECIPITATION
LIFT FOR FILTER SEED
4 544 MT THYSSEN KRUPP LF335-101 UEC/UAIL/REF/LIFT/2024/25 14-08-2024 13-02-2025
BUILDING PREPARARTION
5 LIFT FOR CALCINATION 2 MT THYSSEN KRUPP CALCINATION LF 420-101 UEC/UAIL/REF/LIFT/2024/26 14-08-2024 13-02-2025
LIFT FOR ALUMINA ALUMINA
6 2.5 MT THYSSEN KRUPP LF 440 -101 UEC/UAIL/REF/LIFT/2024/27 14-08-2024 13-02-2025
HANDLING HANDLING
LIFT FOR
7 1 MT THYSSEN KRUPP EVAPORATION LF 260-101 UEC/UAIL/REF/LIFT/2024/28 14-08-2024 13-02-2025
EVAPORATION
LIFT FOR BAUXITE BAUXITE
8 0.5 MT THYSSEN KRUPP LF 232-101 UEC/UAIL/REF/LIFT/2024/29 14-08-2024 13-02-2025
GRINDING GRINDING
9 LIFT(Passanger) 544 KG THYSSEN KRUPP NEW DIEGESTION LF-234-301 UEC/UAIL/REF/LIFT/2024/30 14-08-2024 13-02-2025

10 LIFT(Passanger) 544 KG THYSSEN KRUPP New Seed Area LF-335-301 UEC/UAIL/REF/LIFT/2024/31 14-08-2024 13-02-2025
New
11 LIFT 1 MT THYSSEN KRUPP LF-332-301 UEC/UAIL/REF/LIFT/2024/32 15-08-2024 14-02-2025
PRECIPITATION
12 LIFT 1 MT THYSSEN KRUPP Evaparation New LF-260-301 UEC/UAIL/REF/LIFT/2024/33 15-08-2024 14-02-2025
Oshapada
High power Elivator
13 LIFT(Passanger) 408 KG Township E1Block E1/PL/01 UEC/UAIL/REF/LIFT/2024/34 15-08-2024 14-02-2025
Pvt.Ltd
01
Oshapada
High power Elivator
14 LIFT(Passanger) 408 KG Township E1Block E1/PL/02 UEC/UAIL/REF/LIFT/2024/35 15-08-2024 14-02-2025
Pvt.Ltd
02
Oshapada
Rainbow Elevator
15 LIFT(Passanger) 408 KG Township E2Block E2/PL/01 UEC/UAIL/REF/LIFT/2024/36 15-08-2024 14-02-2025
Ltd
01
Oshapada
Rainbow Elevator
16 LIFT(Passanger) 408 KG Township E2Block E2/PL/02 UEC/UAIL/REF/LIFT/2024/37 15-08-2024 14-02-2025
Ltd
02
Oshapada
Rainbow Elevator
17 LIFT(Passanger) 408 KG Township D1Block D1//PL/01 UEC/UAIL/REF/LIFT/2024/38 15-08-2024 14-02-2025
Ltd
01
Oshapada
JONSON LIFTS PVT
18 LIFT(Passanger) 408 KG Township D2//PL/01 UEC/UAIL/REF/LIFT/2024/39 15-08-2024 14-02-2025
LTD
D2 Block 01
V-TECH POWER
19 SCISSOR LIFT 300 KG DIGESTION SL/234/300KG/01 UEC/UAIL/REF/LIFT/2024/40 15-08-2024 14-02-2025
HYDRAULICS
20 LIFT(Passanger) 800 KG THYSSEN KRUPP Plant End LF/B-026-101 UEC/UAIL/REF/LIFT/2024/41 15-08-2024 14-02-2025
Oshapada
JONSON LIFTS PVT
21 LIFT(Passanger) 408 KG Township C1/PL/01 UEC/UAIL/REF/LIFT/2024/42 15-08-2024 14-02-2025
LTD
C Block
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/22

FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 544 Kg
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF-234-101
Lift height : 29.188 mtr , Lift speed : 1m/s
Location/ Area : Digestion at Refinery
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Passenger Lift
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. Fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up Break: OK, Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client.
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, 544 Kg
renewals or alternations (if any) specified in item -5
7. Others Over load limit setting 480 KG

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/23

FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 544 Kg
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF-250-101
Lift height : 29.198 mtr , Lift speed : 1m/s
Location/Area: Security Filtration at Refinery
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Passenger Lift
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance:Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. Fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals 544 Kg
or alternations (if any) specified in item -5
7. Others Over load limit setting 480 KG

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/24

FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 1.5 MT
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF-332-101
Lift height : 29.999 mtr , Lift speed : 0.5m/s
Location/Area: Precipitation at Refinery
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Freight- cum-Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. Fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break:OK, Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, 1.5 MT
renewals or alternations (if any) specified in item -5
7. Others Over load limit setting 460 kg.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/25
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 544 Kg
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF-335-101
Lift height : 29.188 mtr , Lift speed : 1m/s
Location/Area: Seed Preparation at Refinery
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Passenger Lift
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage & platform and fitting, guides, buffers, interior of OK, spring buffer. Fabricated platforms Hoist way
the hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition..
6.Maximum Safe Working Load subject to repairs, 544 Kg.
renewals or alternations (if any) specified in item -5
7. Others Over load limit setting 480 kg.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/26
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT

Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.


Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 2 MT
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF 420-101,Lift speed : 1m/s
Location/Area: Calcinations
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction : Are all parts of the hoist or lift of Freight- cum-Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. Fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, 2 MT
renewals or alternations (if any) specified in item -5
7. Others  Lift should not be used without overload setting.
 Water logging inside the lift pit. So it should be dry before lift is taking into use.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/27
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT

Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.


Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity- 2.5 MT
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF 440 -101
Lift speed : 1m/s
Location/Area: ALUMINA HANDLING
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift Freight- cum-Passenger
of good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of OK, spring buffer. Fabricated platforms Hoist way
the hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b. Statutory Test Thorough visual examination and load test was carried out
and found good working condition.
6.Maximum Safe Working Load subject to repairs, 2.5 MT
renewals or alternations (if any) specified in item -5
7. Others  Lift pit to be cleaned properly.
 Lift should not be used without overload setting.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/28
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT

Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.


Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity-1 MT
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF 260-101
Lift speed : 1m/s
Location/Area: EVAPORATION
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Freight- cum-Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. Fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, SWL 1 MT
renewals or alternations (if any) specified in item -5
7. Others  Over load limit setting not done
 Lift should not be used without overload setting.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/29
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT

Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.


Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or PASEENGER LIFT
description Capacity-0.5 MT
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF 232-101
Lift speed : 1m/s
Location/Area: BAUXITE GRINDING
Date of construction or reconstruction (if ascertained) : 2010
2. Design & Construction: Are all parts of the hoist or lift of Passenger Lift
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms Hoist way
hoist way or lift way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipments OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, 0.5 MT
renewals or alternations (if any) specified in item -5
7. Others Over load limit setting 420kg.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/30
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification Passenger Lift
number or description Capacity- 544 KG,
Tag No :LF-234-301
Make: ThyssenKrupp Elevator Pvt. Ltd
Location/ Area : DIGESTION (NEW)
Date of construction or reconstruction (if ascertained) : 2022
2. Design & Construction :
Are all parts of the hoist or lift of good mechanical
Passenger
construction, sound material and adequate strength (so far
as ascertainable)?
3. Maintenance:
Are the following parts of the hoist or lift properly
Yes, properly maintained.
maintained and in good working order? If not state what
defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK
h. Safety gear i.e., arrangements for preventing fall of
Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up Break: OK, Down Break: OK
j. Worms or spur gearing OK
k. Other electrical equipment’s OK
l. Hook OK
m. Condition of rope / chain and size Rope dia: 13 mm 06 nos. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and
As per AMC by the client.
the period within which they should be executed
Thorough visual examination and load test was carried
b. Statutory Test
out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals
544 KG
or alternations (if any) specified in item -5
 Overload limit setting 480 kg.
7. Others
 SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 14-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/31
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification Passenger Lift
number or description Capacity- 544 KG,Pass Capacity: 08 Persons
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF-335-301
Location/ Area : New Seed Area
Date of construction or reconstruction (if ascertained) : 2021
2. Design & Construction :Are all parts of the hoist or lift of Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up Break:OK, Down Break: OK
j. Worms or spur gearing OK
k. Other electrical equipment’s OK
l. Hook OK
m. Condition of rope / chain and size Rope dia: 13 mm 06 nos. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client.
the period within which they should be executed
b. Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals 544 KG
or alternations (if any) specified in item -5
7. Others  Overload limit setting 440 kg.
 SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.

I Certified that on 14-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 13-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person
Date: 14-08-2024 For United Eco Care Consultancy Pvt.Ltd.
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/32
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification Passenger Lift
number or description Capacity- 1000 KG
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No : LF-332-301
Location/ Area : New PRECIPITATION
Date of construction or reconstruction (if ascertained) : 2022
2. Design & Construction :Are all parts of the hoist or lift of Freight- cum-Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up Break:OK, Down Break: OK
j. Worms or spur gearing OK
k. Other electrical equipment’s OK
l. Hook OK
m. Condition of rope / chain and size Rope dia: 16 mm 06 nos. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client.
the period within which they should be executed
b. Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals 1000 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Over load limit setting not done
 Lift should not be used without overload setting.

I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.)


Competent Person Counter Signature
Date: 15-08-2024 For United Eco Care Consultancy Pvt.Ltd.
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/33
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification Passenger Lift
number or description Capacity- 1000 KG
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No : LF-260-301
Location/ Area : Evaparation New
Date of construction or reconstruction (if ascertained) : 2022
2. Design & Construction :Are all parts of the hoist or lift of Freight- cum-Passenger
good mechanical construction, sound material and
adequate strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not
state what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up Break:OK, Down Break: OK
j. Worms or spur gearing OK
k. Other electrical equipment’s OK
l. Hook OK
m. Condition of rope / chain and size Rope dia: 16 mm 06 nos. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and As per AMC by the client.
the period within which they should be executed
b. Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals 1000 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Over load limit setting not done.
 Lift should not be used without overload setting.

I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/34
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No:E1/PL/01
Capacity: 408 Kg. or (06 Passengers) Speed-0.5m/sec.
Make: High Power Elevators Pvt. Ltd.
Location: Osapada Township E1 Block 01
b. Date of construction or reconstruction (if ascertained) : 2015
2. Design & Construction: Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and As per AMC given to concerned organization by client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried out
and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 360 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/35
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No:E1/PL/02
Capacity: 408 Kg. or (06 Passengers) Speed-0.5m/sec.
Make: High Power Elevators Pvt. Ltd.
Location: Osapada Township E1 Block 02
b. Date of construction or reconstruction (if ascertained) : 2015
2. Design & Construction: Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and As per AMC given to concerned organization by client
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried out
and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 380 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/36
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No:E2/PL/01
Capacity: 408 Kg. or (06 Passengers) Speed-0.65m/sec.
Make: Rainbow Elevators Ltd.
Location: Osapada Township E2 Block 01
b. Date of construction or reconstruction (if ascertained) : 2015
2. Design & Construction: Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of
Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and As per AMC given to concerned organization by client
the period within which they should be executed
b. Statutory Test Thorough visual examination and load test was carried out
and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 340 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.)


Competent Person Counter Signature
Date: 15-08-2024 For United Eco Care Consultancy Pvt. Ltd.
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/37
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No:E2/PL/02
Capacity: 408 Kg. or (06 Passengers) Speed-0.65m/sec.
Make: Rainbow Elevators Ltd.
Location: Osapada Township E2 Block 02
b. Date of construction or reconstruction (if ascertained) : 2015
2. Design & Construction : Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of
Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and Not available
the period within which they should be executed
b.Statutory Test Thorough visual examination and load test was carried
out and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 320 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/38

FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No:D1/PL/01
Capacity: 408 Kg. or (06 Passengers)
Speed-0.65m/sec.
Make: Rainbow Elevators Ltd.
Location: Osapada Township D1 Block 01
b. Date of construction or reconstruction (if ascertained) : 2015
2. Design & Construction: Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and Not available
the period within which they should be executed
b.Statutory Test Satisfactory
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 400 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/39

FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Osapada Township,Tikiri
Dist- Rayagada, Odisha, 765015.
1. a. Type of Hoist or Lift and identification number or PASSENGERS LIFT
description ID.No: D2//PL/01
Capacity: 408 Kg. or (06 Passengers)
Speed-0.65m/sec.
Make: JONSON LIFTS PVT LTD
Location: Oshapada Township D2 Block 01
b. Date of construction or reconstruction (if ascertained) : 2013
2. Design & Construction: Are all parts of the hoist or lift of Yes
good mechanical construction, sound material and adequate
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift Yes, properly maintained.
properly maintained and in good working order? If not state
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c. Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Found OK.
h. Safety gear i.e., arrangements for preventing fall of Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Up break: OK, Down break: OK
j. Worms or spur gearing OK
k. Other electrical equipments OK
l. Hook OK.
m. Condition of rope / chain and size Usha martin rope dia 13 mm. ISI
n. Body Condition OK
o. Other parts OK
4. What parts (if any) were inaccessible Inside the Gear
5 a. Repairs, renewal or alternations (if any) required and Not available
the period within which they should be executed
b.Statutory Test Satisfactory
6.Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
 Overload limit setting 360 kg.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/S.LIFT/2024/40
FORM-7-A
[As Prescribed under Rule 55, of Section 29, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Osapada Township,Tikiri
Address:
Dist- Rayagada, Odisha, 765015.
SCISSOR LIFT
ID.No: SL/234/300KG/01
1. a. Type of Hoist or Lift and identification number or
Capacity: 300 KG
description
Make: V-TECH POWER HYDRAULICS
Location: DIGESTION
b. Date of construction or reconstruction (if ascertained) : 2020
2. Design & Construction: Are all parts of the hoist or lift of
good mechanical construction, sound material and adequate Yes
strength (so far as ascertainable)?
3. Maintenance: Are the following parts of the hoist or lift
properly maintained and in good working order? If not state Yes, properly maintained.
what defects have been found-
a. Enclosure of hoist way or lift way Found OK.
b. Landing gates & cage-gate(s) Not applicable
c. Interlocks and the landing gates & cage-gate(s) Not applicable
d. Other gate fastenings Found OK, fitted with cable , clamps etc.
e. Cage & platform and fitting, guides, buffers, interior of the
Found OK
hoist way or lift way
f. Overrunning devices Electrical & electronics devices are found OK.
g. Suspension ropes or chain and their attachments Not Applicable
h. Safety gear i.e., arrangements for preventing fall of
Safety gears including devices etc…found OK.
platform or cage breaks
i. Breaks Found OK.
j. Worms or spur gearing Found OK
k. Other electrical equipments Found OK
l. Hook Not applicable
m. Condition of rope / chain and size Not applicable
n. Body Condition Found OK
o. Other parts Found OK
4. What parts (if any) were inaccessible Not applicable
5 a. Repairs, renewal or alternations (if any) required and
Not Applicable
the period within which they should be executed
Thorough visual examination and load test was carried out
b.Statutory Test
and found good working condition.
6.Maximum Safe Working Load subject to repairs, renewals
The rated load of the machine is 300 KGS
or alternations (if any) specified in item -5
7. Others  SWL, Cap, ID, Location, Test & Due date to be properly displayed in the Lift.
I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct report
of the result.
This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.)


Counter Signature
Competent Person
For United Eco Care Consultancy Pvt. Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/41
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or Freight- cum-Passenger Lift
description Capacity- 800 KG
Make: ThyssenKrupp Elevator Pvt. Ltd
Tag No :LF/B-026-101
Location/ Area : Plant End
Date of construction or reconstruction (if ascertained) : 2020
2. Design & Construction : Freight- cum-Passenger
Are all parts of the hoist or lift of good mechanical
construction, sound material and adequate strength (so far
as ascertainable)?
3. Maintenance: Yes, properly maintained.
Are the following parts of the hoist or lift properly
maintained and in good working order? If not state what
defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly
maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of platform Safety gears including devices etc…found OK.
or cage breaks
i. Breaks Up Break:OK, Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipment’s OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 16 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and the As per AMC by the client.
period within which they should be executed
b.Statutory Test Thorough visual examination and load test was
carried out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals 800 KG
or alternations (if any) specified in item -5
7. Others  Overload setting not done. It should be done before taken into use.
 Schedule maintenance should be done in regular interval. SOP & SMP should be followed
before use.

I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.

This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 15-08-2024
Er. Manas Ranjan Behura, B.E (Mech.)
UNITED ECO CARE CONSULTANCY PVT. LTD. Certificate No:CP(O) NO.21/G,Dt:24/11/2023 & NO.23/G Dt : 01/08/2023
Regd. Office: Flat No: 006, Prasanti Apartment, Deulsahi, Competent Person Recognized by Govt. of Odisha
Tulsipur,Cuttack-08, Odisha, Ph: +91 9337312700 Under Factories Act,1948 & Odisha Factories Rules,1950
Email: [email protected], [email protected] For Section-28,29,31 & Rule-3A, ASNT NDT Level-II Examiner,
External Safety Auditor recognized by Director of Factories & Boilers, Odisha
TC NO: UEC/UAIL/REF/LIFT/2024/42
FORM-7-A
[As Prescribed under Rule 55, of Section 28, Odisha Factory Rules, 1950]
REPORT OF EXAMINATION OF HOIST or LIFT
Occupier (or owner) of Premises: M/S. UTKAL ALUMINA INTERNATIONAL LTD.
Address: Vill- Doraguda, Post- Kuchipadar, Via- Tikiri
Dist- Rayagada, Odisha, 765015.
1. Type of Hoist or Lift and identification number or Passenger Lift
description Capacity- 408 KG
Make: JONSON LIFTS PVT LTD
Tag No : C1/PL/01
Location/ Area : Oshapada Township C Block
Date of construction or reconstruction (if ascertained) : 2023
2. Design & Construction : Passenger
Are all parts of the hoist or lift of good mechanical
construction, sound material and adequate strength (so far
as ascertainable)?
3. Maintenance: Yes, properly maintained.
Are the following parts of the hoist or lift properly
maintained and in good working order? If not state what
defects have been found-
a.Enclosure of hoist way or lift way Found OK.
b.Landing gates & cage-gate(s) Found in good conditions & fitted with limit switches.
c.Interlocks and the landing gates & cage-gate(s) Found OK, fitted with guide roller & bushes.
d.Other gate fastenings Found OK, fitted with cable , clamps etc.
e.Cage& platform and fitting, guides, buffers, interior of the OK, spring buffer. fabricated platforms
hoist way or lift way Hoist way including safety devices properly
maintained.
f. Overrunning devices Electrical & electronics devices are found OK.
g.Suspension ropes or chain and their attachments Found OK.
h.Safety gear i.e., arrangements for preventing fall of platform Safety gears including devices etc…found OK.
or cage breaks
i. Breaks Up Break:OK, Down Break: OK
j. Worms or spur gearing OK
k.Other electrical equipment’s OK
l.Hook OK
m.Condition of rope / chain and size Rope dia 13 mm. ISI
n.Body Condition OK
o.Other parts OK
4. What parts (if any) were inaccessible In Side The Gear box
5.a.Repairs, renewal or alternations (if any) required and the As per AMC by the client.
period within which they should be executed
b.Statutory Test Thorough visual examination and load test was
carried out and found good working condition.
6. Maximum Safe Working Load subject to repairs, renewals 408 KG
or alternations (if any) specified in item -5
7. Others  Overload setting not done. It should be done before taken into use.
 Schedule maintenance should be done in regular interval. SOP & SMP should be followed
before use.

I Certified that on 15-08-2024 the above equipment has been thoroughly examined and that the above is a correct
report of the result.

This report is valid up to on 14-02-2025

Er. Manas Ranjan Behura, B.E (Mech.) Counter Signature


Competent Person For United Eco Care Consultancy Pvt.Ltd.
Date: 15-08-2024