0% found this document useful (0 votes)
7 views7 pages

Memberreport 2

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 7

JOB SUMMARY REPORT

Main House
Level
Member Name Results (Max UTIL %) Current Solution Comments
Roof: Joist Passed (51% M) 1 piece(s) 2 x 8 DF No.2 @ 16" OC
Roof: Girder Passed (86% M) 1 piece(s) 6 x 10 DF No.1
Wood Post Passed (33% B/C) 1 piece(s) 6 x 6 DF No.2
Pergola: Joist Passed (100% ΔL) 1 piece(s) 2 x 6 DF No.2 @ 12" OC
Pergola: Beam Passed (70% M) 1 piece(s) 4 x 10 DF No.2
Pergola Post Passed (32% f꜀) 1 piece(s) 4 x 4 DF No.2

ForteWEB Software Operator Job Notes


10/14/2024 12:58:15 PM UTC
Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8
(720) 935-4498
[email protected] File Name: Main House

Page 1 / 7
MEMBER REPORT PASSED
Level, Roof: Joist
1 piece(s) 2 x 8 DF No.2 @ 16" OC

Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Length : 14' 5 15/16"
System : Roof
Member Reaction (lbs) 363 @ 1' 5 3/4" 2300 (3.50") Passed (16%) -- 1.0 D + 1.0 Lr (All Spans)
Member Type : Joist
Shear (lbs) 259 @ 2' 2 9/16" 1631 Passed (16%) 1.25 1.0 D + 1.0 Lr (All Spans)
Building Use : Residential
Moment (Ft-lbs) 865 @ 7' 7 7/8" 1700 Passed (51%) 1.25 1.0 D + 1.0 Lr (Alt Spans) Building Code : IBC 2021
Live Load Defl. (in) 0.184 @ 7' 7 5/16" 0.630 Passed (L/823) -- 1.0 D + 1.0 Lr (Alt Spans) Design Methodology : ASD
Total Load Defl. (in) 0.323 @ 7' 7 3/8" 0.840 Passed (L/468) -- 1.0 D + 1.0 Lr (Alt Spans) Member Pitch : 3/12
• Deflection criteria: LL (L/240) and TL (L/180).
• Overhang deflection criteria: LL (2L/240) and TL (2L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on NDS.

Bearing Length Loads to Supports (lbs)

Supports Total Available Required Dead Roof Live Factored Accessories

1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 158 205 363 Blocking
2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 129 167 296 Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 11' 9" o/c


Bottom Edge (Lu) 14' 4" o/c
•Maximum allowable bracing intervals based on applied load.
•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions.

Dead Roof Live

Vertical Load Location (Side) Spacing (0.90) (1.25) Comments

1 - Uniform (PSF) 0 to 13' 11" 16" 15.0 20.0 Default Load

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes


10/14/2024 12:58:15 PM UTC
Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House

Page 2 / 7
MEMBER REPORT PASSED
Level, Roof: Girder
1 piece(s) 6 x 10 DF No.1

Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Length : 28' 1"
System : Roof
Member Reaction (lbs) 5659 @ 8' 7 11/16" 8181 (3.50") Passed (69%) -- 1.0 D + 1.0 Lr (All Spans)
Member Type : Drop Beam
Shear (lbs) 3002 @ 9' 6 15/16" 7402 Passed (41%) 1.25 1.0 D + 1.0 Lr (All Spans)
Building Use : Residential
Moment (Ft-lbs) -9993 @ 8' 7 11/16" 11634 Passed (86%) 1.25 1.0 D + 1.0 Lr (All Spans) Building Code : IBC 2021
Live Load Defl. (in) 0.435 @ 19' 2 1/16" 0.964 Passed (L/532) -- 1.0 D + 1.0 Lr (Alt Spans) Design Methodology : ASD
Total Load Defl. (in) 0.796 @ 19' 2 3/8" 1.285 Passed (L/291) -- 1.0 D + 1.0 Lr (Alt Spans) Member Pitch : 0/12
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• -236 lbs uplift at support located at 2". Strapping or other restraint may be required.
• Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5.
• Applicable calculations are based on NDS.

Bearing Length Loads to Supports (lbs)

Supports Total Available Required Dead Roof Live Factored Accessories

1 - Stud wall - SPF 3.50" 3.50" 1.50" 36 335/-272 371/-236 Blocking


2 - Stud wall - SPF 3.50" 3.50" 2.42" 2611 3048 5659 Blocking
3 - Stud wall - SPF 3.50" 3.50" 1.50" 1052 1239 2292 Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 28' 1" o/c


Bottom Edge (Lu) 28' 1" o/c
•Maximum allowable bracing intervals based on applied load.

Dead Roof Live


Tributary (0.90) (1.25)
Vertical Loads Location (Side)
Width
Comments

0 - Self Weight (PLF) 0 to 28' 1" N/A 13.2 --


Linked from: Roof:
1 - Uniform (PLF) 0 to 28' 1" (Front) N/A 118.5 153.8
Joist, Support 1
• Side loads are assumed to not induce cross-grain tension.

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes


10/14/2024 12:58:15 PM UTC
Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House

Page 3 / 7
MEMBER REPORT PASSED
Level, Wood Post
1 piece(s) 6 x 6 DF No.2

Post Height: 8' 6"

Design Results Actual Allowed Result LDF Load: Combination


Slenderness 19 50 Passed (37%) -- --
Compression (lbs) 5659 20371 Passed (28%) 1.25 1.0 D + 1.0 Lr
Base Bearing (lbs) 5659 898425 Passed (1%) -- 1.0 D + 1.0 Lr
Bending/Compression 0.33 1 Passed (33%) 1.25 1.0 D + 1.0 Lr
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.

Supports Type Material Member Type : Free Standing Post


Building Code : IBC 2021
Base Plate Steel
Design Methodology : ASD

Max Unbraced Length Comments


Full Member Length No bracing assumed.

Drawing is Conceptual

Dead Roof Live

Vertical Load (0.90) (1.25) Comments

Linked from: Roof: Drop Beam,


1 - Point (lb) 2611 3048
Support 2

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes 10/14/2024 12:58:15 PM UTC


Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House
Page 4 / 7
MEMBER REPORT PASSED
Level, Pergola: Joist
1 piece(s) 2 x 6 DF No.2 @ 12" OC

Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Length : 17' 2"
System : Floor
Member Reaction (lbs) 134 @ 1' 1 3/4" 2231 (3.50") Passed (6%) -- 1.0 D + 1.0 L (Adj Spans)
Member Type : Joist
Shear (lbs) 107 @ 1' 9" 990 Passed (11%) 1.00 1.0 D + 1.0 L (Adj Spans)
Building Use : Residential
Moment (Ft-lbs) 446 @ 8' 10 5/8" 848 Passed (53%) 1.00 1.0 D + 1.0 L (Alt Spans) Building Code : IBC 2021
Live Load Defl. (in) 0.386 @ 8' 10 1/2" 0.386 Passed (L/480) -- 1.0 D + 1.0 L (Alt Spans) Design Methodology : ASD
Total Load Defl. (in) 0.576 @ 8' 10 9/16" 0.773 Passed (L/322) -- 1.0 D + 1.0 L (Alt Spans)
TJ-Pro™ Rating N/A N/A N/A -- N/A
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on NDS.
• No composite action between deck and joist was considered in analysis.

Bearing Length Loads to Supports (lbs)

Supports Total Available Required Dead Floor Live Factored Accessories

1 - Stud wall - SPF 3.50" 3.50" 1.50" 45 89 134 Blocking


2 - Stud wall - SPF 3.50" 3.50" 1.50" 41 83 124 Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 17' 2" o/c


Bottom Edge (Lu) 17' 2" o/c
•Maximum allowable bracing intervals based on applied load.

Dead Floor Live

Vertical Load Location (Side) Spacing (0.90) (1.00) Comments

1 - Uniform (PSF) 0 to 17' 2" 12" 5.0 10.0 Default Load

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes


10/14/2024 12:58:15 PM UTC
Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House

Page 5 / 7
MEMBER REPORT PASSED
Level, Pergola: Beam
1 piece(s) 4 x 10 DF No.2

Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Length : 28' 11 1/2"
System : Floor
Member Reaction (lbs) 2362 @ 14' 5 3/4" 5206 (3.50") Passed (45%) -- 1.0 D + 1.0 L (Adj Spans)
Member Type : Drop Beam
Shear (lbs) 1051 @ 15' 4 3/4" 3885 Passed (27%) 1.00 1.0 D + 1.0 L (Adj Spans)
Building Use : Residential
Moment (Ft-lbs) -3143 @ 14' 5 3/4" 4492 Passed (70%) 1.00 1.0 D + 1.0 L (Adj Spans) Building Code : IBC 2021
Live Load Defl. (in) 0.121 @ 7' 5 7/16" 0.444 Passed (L/999+) -- 1.0 D + 1.0 L (Alt Spans) Design Methodology : ASD
Total Load Defl. (in) 0.162 @ 21' 8 5/16" 0.667 Passed (L/986) -- 1.0 D + 1.0 L (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.

Bearing Length Loads to Supports (lbs)

Supports Total Available Required Dead Floor Live Factored Accessories

1 - Stud wall - SPF 3.50" 3.50" 1.50" 331 628 959 Blocking
2 - Stud wall - SPF 3.50" 3.50" 1.59" 879 1483 2362 Blocking
3 - Stud wall - SPF 3.50" 3.50" 1.50" 331 628 959 Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 29' o/c


Bottom Edge (Lu) 29' o/c
•Maximum allowable bracing intervals based on applied load.

Dead Floor Live


Tributary (0.90) (1.00)
Vertical Loads Location (Side)
Width
Comments

0 - Self Weight (PLF) 0 to 28' 11 1/2" N/A 8.2 --


Linked from:
1 - Uniform (PLF) 0 to 28' 11 1/2" (Front) N/A 45.0 89.0 Pergola: Joist,
Support 1
• Side loads are assumed to not induce cross-grain tension.

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes


10/14/2024 12:58:15 PM UTC
Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House

Page 6 / 7
MEMBER REPORT PASSED
Level, Pergola Post
1 piece(s) 4 x 4 DF No.2

Post Height: 7' 8"

Design Results Actual Allowed Result LDF Load: Combination


Slenderness 26 50 Passed (53%) -- --
Compression (lbs) 2362 7482 Passed (32%) 1.00 1.0 D + 1.0 L
Base Bearing (lbs) 2362 363825 Passed (1%) -- 1.0 D + 1.0 L
Bending/Compression 0.31 1 Passed (31%) 1.00 1.0 D + 1.0 L
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.

Supports Type Material Member Type : Free Standing Post


Building Code : IBC 2021
Base Plate Steel
Design Methodology : ASD

Max Unbraced Length Comments


Full Member Length No bracing assumed.

Drawing is Conceptual

Dead Floor Live

Vertical Load (0.90) (1.00) Comments

Linked from: Pergola: Beam,


1 - Point (lb) 879 1483
Support 2

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document-library.
The product application, input design loads, dimensions and support information have been provided by AMANUEL WUBNEH P.E.

ForteWEB Software Operator Job Notes 10/14/2024 12:58:15 PM UTC


Amanuel Wubneh, P.E. Mr. Yehego Residence
Amen Design and Consulting 3080 S Kearney St Denver, CO 80222 ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3
(720) 935-4498
[email protected] File Name: Main House
Page 7 / 7

You might also like