Occupancy Category I Table 103-1 Seismic Zone 4 Table 208-3 Seismic Zone Factor 0.4 Table 208-3 Seismic Source Type Type A Figure 208-2C Importance Factor, I 1.5 Table 208-1 Ductility Coefficient, R 8.5 Table 208-11A Distance from Fault Line 6.7 km FaultFinder App Near Source Factor, Na 1.132 Table 208-4 Near Source Factor, Nv 1.464 Table 208-5 Soil Profile SD Table 208-2
WIND LOAD Sec. 207
Occupancy Category I Table 103-1 Wind Pressure 270 kph Figure 207.5.1-C Surface Roughness Category B Sec. 207.5.6.2 Enclosure Classification Enclosed Sec. 207A.10 Directionality Factor 0.85 Table 207A.6-1 Topographic Factor 1 Sec. 207A.8.2 Gust Effect Factor 0.85 Sec. 207A.9.1 Internal Pressure Coefficient± 0.18 Table 207A11-1
PROJECT TITLE: CIVIL/STRUCTURAL ENGINEER:
STRUCTURAL ANALYSIS AND DESIGN OF TWO-
Ago, Panaot S. Gallego, Renzthor Paul S STOREY THEATRE BUILDING Ismael, Ben Ladin A. Baito, Marydhel C. LOCATION: Bayog, Kenneth John E. Niervo, Kaye Abegail C. KABACAN, NORTH COTABATO Catedral, Joswe Ceasar Quiñones, Thomas Joshua B D. OWNER: UNIVERSITY OF SOUTHERNMINDANAO Rotaquio, Arianne Gee Daquilos, Junaray P. Ermac, Genilyn