You are on page 1/ 6

885026

®
2595 MHz BAW Filter

General Description
The 885026 is a high-performance Bulk Acoustic Wave
(BAW) filter designed to meet the strict LTE rejection
requirements for use in B38.

885026 is specifically designed to meet the high-


performance expectations of insertion loss and rejection
for LTE transmit systems under all operating conditions.

The 885026 uses common module packaging


techniques to achieve the industry standard 1.4 x 1.2 x
0.46 mm footprint.

Product Features
• Highly selective BAW filter achieving low
insertion loss over full bandwidth and operating
conditions
Functional Block Diagram • Rejection in WLAN band of 40dB minimum
• Rejection in Band 7 Rx band of 10dB minimum
Gnd
• Performance −20 to +90 ºC
• Ceramic chip-scale Package (CSP)
5 4 Output
• Small Size: 1.4 x 1.2 x 0.46 mm
Input 1 • Hermetically Sealed
• RoHS compliant, Pb-free Pb
2 3 Gnd
bb
b
Gnd
Top View Applications P

bv
For Band 38 TD-LTE applications
• B7/B38/B40 LTE handset, data cards, mobile
routers P
Pin Configuration – Single Ended b
Ended
Pin No. Label
1 Input Ordering Information
4 Output
2,3,5 Ground Part No. Description
885026 Packaged part
885026-EVB Evaluation board
Standard T/R size = 10,000 units/reel

DATA SHEET: REV J - 1 of 6


August 2019 Subject to change without notice www.qorvo.com
885026
®
2595 MHz BAW Filter

Absolute Maximum Ratings MTTF


Parameter Rating Parameter Min
Storage Temperature -40 to +125 °C RF Input Power +29dBm, CW, in
+ 95 °Chrs.
10,000
Operable Temperature -40 to +90 °C band at 55 °C
RF Input Power, CW, 50Ω, T=25 °C +29dBm
Note: Operation of this device outside the parameter > 2M hours
ranges given may cause permanent damage.

Electrical Specifications (1)(2)


Conditions unless otherwise noted: (3) Device Temperature = 0°C to +70°C.
Parameter (2) Conditions Min Typ Max Units
Center Frequency - 2595 dB
2570 – 2620 MHz - 1.5 2.5 dB
Insertion Loss
2570 – 2620 MHz 1.5 2.1 (4) dB
10 – 1574 MHz 30 33 -
1559 – 1606 MHz 33 34 -
1607 – 2300 MHz 32 34 -
2400 – 2500 MHz 39 41 -
Attenuation (5) dB
2505 – 2535 MHz(6) 20 37 -
2645 – 2670 MHz 10 16 -
5150 – 5230 MHz 30 39 -
7725 – 7845 MHz 25 32 -
Input VSWR 2570 – 2620 MHz - 1.6 :1 2.0:1 -
Output VSWR 2570 – 2620 MHz - 1.6 :1 2.0:1 -
Source/Load Impedance (7) Single-ended - 50 - Ω

Notes:

1. All specifications are based on the test circuit shown on page 3


2. Electrical margin has been built into the design to account for the variations due to manufacturing tolerances.
3. In production, devices will be tested at room temperature to a guard-banded specification to ensure electrical compliance over temperature
4. At 25 °C only
5. Measurement made relative to zero dB
6. Specified from 0°C to +55°C only.
7. This is the optimum impedance in order to achieve the performance shown.

DATA SHEET: REV J - 2 of 6


August 2019 Subject to change without notice www.qorvo.com
885026
®
2595 MHz BAW Filter

Evaluation Board

Notes:
1. Matching component values shown are for the specified TriQuint evaluation board. Value adjustment may be required in end
user product circuits depending on component manufacturer and PCB material.
2. PCB: .500 x.500 x .062; Construction: ½ oz. Cu Top Layer; TLY-5A (.0075) ½ oz. Cu Middle Layer, FR4; ½ oz. Cu Bottom
Layer. (dimensions are in inches)

Bill of Material
Reference Des. Value Description Manuf. Part Number
L1 20 nH 0201 chip inductors ±3% MuRata LQP03TN20NH02
SMA N/A SMA connector Radiall USA 9602-1111-018
PCB N/A 3-layer Multiple 960999

PCB Mounting Pattern


Notes:
1. All dimensions are in millimeters. Angles are in degrees.
2. This drawing specifies the mounting pattern used on the Qorvo
evaluation board for this product. Some modification may be necessary
to suit end user assembly materials and processes.

DATA SHEET: REV J - 3 of 6


August 2019 Subject to change without notice www.qorvo.com
885026
®
2595 MHz BAW Filter

Performance Plots
Frequency Response Passband Response
0 0

-10
-1

-20
-2
d d
-30
B B
-3
-40

-4
-50

-60 -5
2100 2350 2600 2850 3100 2545 2570 2595 2620 2645

Frequency (MHz) Frequency (MHz)


Wideband Response Input / Output VSWR
0 L 3
i n
2.5
-10 n s
2
e
M 1.5 c
-20
a
1
d g 2545 2570 2595 2620 2645
-30
B
L 3
-40 i
2.5
n d
2 e
-50
M 1.5 g
a
-60 1
0 2000 4000 6000 8000 g 2545 2570 2595 2620 2645
Frequency (MHz) Frequency (MHz)
Input Smith Chart Output Smith Chart
1 1

0.8 0.8

0.6 0.6

0.4 0.4

0.2 0.2

0 0
-1 -0 .5 0 0.5 1 -1 -0 .5 0 0.5 1

-0 .2 -0 .2

-0 .4 -0 .4

-0 .6 -0 .6

-0 .8 -0 .8

-1
-1

DATA SHEET: REV J - 4 of 6


August 2019 Subject to change without notice www.qorvo.com
885026
®
2595 MHz BAW Filter

Package Information, Marking and Dimensions


Marking MFG site Package Style: CSP-5CT
code Dimensions: 1.4 x 1.2 x 0.46 mm
Date code
ID dot
62 M Body: Al2O3 ceramic
Lid: Kovar or Alloy 42, Au over Ni plated
WWY Terminations: Au plating 0.5 - 1.0 μm, over a 2-6 μm Ni
plating

The date code consists of: WW = 2 digit week,


Y = last digit of year, M = manufacturing site code
0.46 NOM.
1.40
0.50 MAX.
1.25
Notes:
1. All dimensions shown are typical in millimeters.
0.50 2. Unless otherwise specified all tolerances are ±0.05mm
except length and width that are specified as ± 0.1mm.
3. An asterisk (*) in front of the marking code indicates
1.20 0.325 0.25 0.90 prototype.

0.25

Tape and Reel information


8.8
2.7 Ø330 ID dot Section A-A 4.0
Ø1.5 A 1.75
0.3 2.0

3.5 8.0
Ø102 Ø20.2 Direction of travel 1.73
2.0
Ø13.0
1.47 4.0 A
0.65
Ø1.0

Standard T/R size=10,000 units/reel.


All dimensions are in millimeters.

DATA SHEET: REV J - 5 of 6


August 2019 Subject to change without notice www.qorvo.com
885026
®
2595 MHz BAW Filter

Handling Precautions
Parameter Rating Standard
ESD – Human Body Model (HBM) Class 1C ESDA / JEDEC JS-001 Caution!
ESD – Charge Device Model (CDM) Class C1 ESDA/JEDEC JS-002 ESD-Sensitive Device
MSL – Moisture Sensitivity Level N/A * Hermetic package
*Hermetically sealed ceramic package

Solderability
Compatible with both lead-free (260°C max. reflow temp.) and tin/lead (245°C max. reflow temp.) soldering processes.
Solder profiles available upon request.

RoHS Compliance
This part is compliant with 2011/65/EU RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment) as amended by Directive 2015/863/EU. This product also has the following attributes:
• Lead Free
• Halogen Free (Chlorine, Bromine)



Antimony Free
TBBP-A (C15H12Br402) Free
PFOS Free
Pb
• SVHC Free

Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations:
Web: www.qorvo.com
Tel: 1-844-890-8163
Email: [email protected]

Important Notice
The information contained herein is believed to be reliable; however, Qorvo makes no warranties regarding the information contained
herein and assumes no responsibility or liability whatsoever for the use of the information contained herein. All information contained
herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for
Qorvo products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by
such information. THIS INFORMATION DOES NOT CONSTITUTE A WARRANTY WITH RESPECT TO THE PRODUCTS
DESCRIBED HEREIN, AND QORVO HEREBY DISCLAIMS ANY AND ALL WARRANTIES WITH RESPECT TO SUCH PRODUCTS
WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR
OTHERWISE, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Without limiting the generality of the foregoing, Qorvo products are not warranted or authorized for use as critical components in
medical, life-saving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe
personal injury or death.
Copyright 2019 © Qorvo, Inc. | Qorvo is a registered trademark of Qorvo, Inc.

DATA SHEET: REV J - 6 of 6


August 2019 Subject to change without notice www.qorvo.com