Panel cutout
71mm
36mm
GS-UV-C-2 GS-UV-C-3
59 mm
29mm
Side Lock
PANEL
GASKET
Features :
Ÿ Range: 0 to 99 Minutes/Seconds
Ÿ Relay Output for UV-C. CONTROLLER
Ÿ Timer setting in Minutes or Seconds.
Ÿ Timer run automatically as per setting.
Suggested Wiring GS-UV-C-2 / GS-UV-C-3
Ÿ Timer Hold/start manually.
Ÿ Timer hold at Door open & Buzzer will turn ON at
timer over. 8(1)A 250V MAX
DOOR
LIMIT SWITCH
Introduction
UV Germicidal Irradiation is a disinfection method that uses short-
wavelength ultraviolet (ultraviolet C or UV-C) light to kill or inactivate
microorganisms by destroying nucleic acids and disrupting their DNA,
leaving them unable to perform vital cellular functions. UV Lamp
Door open sensing is provided to switch off the UV-Light. Buzzer will be
ON when timer is over.
USER INTERFACE
Touch to increase Timer count value by 1
Caution UP Key Minute/Second.
WIRING: The electrical wiring should be done as shown in the
Touch to decrease Timer count value by 1
diagram. The power supply circuit should be connected to a protection
switch. The terminals admit wires of upto 2.5sq mm. Down Key Minute/Second.
Touch to start or hold the timer.
WARNING: Improper wiring may cause irreparable damage and
personal injury. Kindly ensure that wiring is done by qualified personnel
Also to save the timer count, if it is changed
only. Start/Hold Key by using up/down key.
Touch and hold for 1 sec to stop & reset the
Maintenance: Cleaning: Clean the surface of the controller with a soft
moist cloth. Do not use abrasive detergents, petrol, alcohol or solvents.
Reset Key timer at last saved value.