Rheem Series Air Conditioners: Classic
Rheem Series Air Conditioners: Classic
Rheem Series Air Conditioners: Classic
Air
RA14 Series
RA14 Series
Efficiencies up to 14 SEER/11.5 EER
Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
16.0
• Composite base pan – dampens sound, captures louver • Diagnostic service window with two-fastener opening –
panels, eliminates corrosion and reduces number of fasteners provides access to the high and low pressure.
needed • External gauge port access – allows easy connection of
• Powder coat paint system – for a long lasting professional finish “low-loss” gauge ports
• Scroll compressor – uses 70% fewer moving parts for higher • Single-row condenser coil – makes unit lighter and allows
efficiency and increased reliability thorough coil cleaning to maintain “out of the box”
• Modern cabinet aesthetics – increased curb appeal with visu- performance
ally appealing design • 35% fewer cabinet fasteners and fastener-free base – allow
• Curved louver panels – provide ultimate coil protection, for faster access to internal components and hassle-free
enhance cabinet strength, and increased cabinet rigidity panel removal
• Optimized fan orifice – optimizes airflow and reduces unit • Service trays – hold fasteners or caps during service calls
sound • QR code – provides technical information on demand for
• Rust resistant screws – confirmed through 1500-hour salt faster service calls
spray testing • Fan motor harness with extra long wires allows unit top to be
• PlusOne™ Expanded Valve Space – 3"-4"-5" service valve removed without disconnecting fan wire.
space – provides a minimum working area of 27-square
inches for easier access
• PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
TABLE OF CONTENTS
Standard Feature ......................................................................................................3
Available SKUs ........................................................................................................3
Features & Benefits ..............................................................................................4-5
Model Number Identification ....................................................................................6
General Data/Electrical Data ....................................................................................7
Accessories ............................................................................................................8
Weighted Sound Power ............................................................................................8
Unit Dimensions........................................................................................................9
Clearances..............................................................................................................10
Wiring Diagrams ....................................................................................................11
Application Guidelines ............................................................................................11
Refrigerant Line Size Information ......................................................................12-15
Performance Data ..................................................................................................16
Guide Specifications ..............................................................................................17
Limited Warranty ....................................................................................................18
2
Standard Feature/Available SKUs
Air
RA14 Series
Available SKUs
Available Models Description
RA1418AJ1NA Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1418AJ1NB Classic ® Series 1 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1424BJ1NA Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1424BJ1NB Classic ® Series 2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1430AJ1NA Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1430AJ1NB Classic ® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1436AC1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/3/60
RA1436AD1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1436AJ1NA Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1436AJ1NB Classic ® Series 3 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1442AD1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1442CC1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/3/60
RA1442CJ1NA Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1442CJ1NB Classic ® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1448AC1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/3/60
RA1448AD1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1448AJ1NA Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1448AJ1NB Classic ® Series 4 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA1460CC1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/3/60
RA1460CD1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-460/3/60
RA1460CJ1NA Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60
RA1460CJ1NB Classic ® Series 5 ton 14 SEER Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
3
Features & Benefits
Air
RA14 Series
7 11 17
8
10 9
4
Features & Benefits
Air
RA14 Series
The entire cabinet has powder post paint ( 20 ) achieving 1000 Optional Accessories
hour salt spray rating, allowing the cabinet to retain its aesthetics (Refer to accessory chart for model #)
throughout its life.
Compressor Crankcase Heater
Protects against refrigerant migration that can occur during low
24 ambient operation
20
Compressor Sound Cover
23 • Reinforced vinyl compressor cover containing a 1½ inch thick
batt of fiberglass insulation
22 • Open edges are sealed with a one-inch wide hook and loop
21
fastening tape
Compressor Hard Start Kit
Scroll compressors with standard internal pressure relief and • Single-phase units are equipped with a PSC compressor
internal thermal overload are used on all capacities assuring motor, this type of motor normally does not need a potential
longevity of high efficient and quiet operation for the life of the relay and start capacitor
product. • Kit may be required to increase the compressor starting
Each unit is shipped with filter drier for field installation and will torque, in conditions such as low voltage
trap any moisture or dirt that could contaminate the refrigerant Low Ambient Kit
system. • Air conditioners operate satisfactorily in the cooling mode
down to 55°F outdoor air temperature without any additional
controls
25
• This Kit can be added in the field enabling unit to operate
properly down to 0° in the cooling mode
• Crankcase heater and freezestat should be installed on com-
pressors equipped with a low ambient kit
3"/6"/12"
• Gray high density polyethylene feet are available to raise unit
All cabinets have industry leading structural strength due to the
off of mounting surface away from moisture
composite base pan ( 21 ), interlocking corner post ( 22 ), formed
curved louver panels ( 23 ) and drawn top cover ( 24 ) making it Low Pressure
the most durable cabinet on the market today. • Can be added in field enabling the unit to shut off compressor
on loss of charge
Each RA14 capacity has undergone rigorous psychometric test-
ing to assure performance ratings of capacity, SEER and EER NOTE: Unit can be purchased with high and low pressure
per AHRI Standard 210/240 rating conditions. Also installed at factory. (Refer to SKU list)
each unit bears the UL mark and each unit is certified
to UL 1995 safety standards. High Pressure
• Can be added in field enabling unit to shut off compressor if
Each unit has undergone specific strain and modal testing to unit loses outdoor fan operation.
assure tubing ( 25 ) is outside the units natural frequency and that
the suction and discharge lines connected to the compressor NOTE: Unit can be purchased with high and low pressure
withstand any starting, steady state operation or shut down installed at factory. (Refer to SKU list)
forces imposed by the compressor. Decorative Top
All units have been sound tested in sound chamber to AHRI 270 • Can be installed on fan grille
rating conditions, and A-weighted Sound Power Level tables
produced, assuring units have acceptable noise qualities (see
page 9). Each unit has been ran in cooling operation at 95°F and
82°F and sound ratings for the RA14 range from as low as 74
dBA to 77 dBA.
All units have been ship tested to assure units meet stringent
“over the road” shipping conditions.
As manufactured all units in the RA14 family have cooling capa-
bility to 55 °F. Addition of low ambient control will allow the unit
to operate down to 0°F. Factory testing is performed on each
unit. All component parts meet well defined specification and
continually go through receiving inspections. Each component
installed on a unit is scanned, assuring correct component uti-
lization for a given unit capacity and voltage. All condenser coils
are leak tested with pressurization test to 550#’s and once
installed and assembled, each units’ complete refrigerant
system is helium leak tested. All units are fully charged from the
factory for up to 15 feet of piping. All units are factory run tested.
The RA14 has a 10-year conditional compressor and parts war-
ranty (registration required).
5
Air Conditioners*
6
Air
R A 14 24 A J 1 N A *
Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option
Category BTU/HR Code
Rheem A - Air Conditioners 14 - 14 SEER 18 - 18,000 [5.28 kW] A - 1st Design J - 1ph, 208-230/60 1 - Single-stage N - Non-Communicating A - 1st Design N/A
RA14 Series
Physical Data
PHYSICAL DATA
Model No. RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 68 80 87 106 134 129 199
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 9.1 11.1 12.1 14.8 17.3 18.9 28.27
Net face area – Inner Coil — — — — — — —
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 22 22 22 22 22 22 22
Outdoor Fan
Diameter – in. 20 20 20 24 24 26 26
Number of blades 2 2 2 3 3 2 3
Motor hp 1/10 1/8 1/8 1/6 1/5 1/5 1/3
CFM 2225 2295 2605 3105 4105 4264 5000
RPM 1075 1121 1075 850 833 820 795
watts 130 138 142 173 236 236 239
Shipping weight – lbs. 143 148 158 178 207 232 268
Operating weight – lbs. 122 141 151 171 200 221 261
Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 20 25 25 30 35 45 50
Minimum circuit ampacity³ 13 15 17 19 23 27 32
Compressor
Rated load amps 9.7 10.9 12.8 14.1 16.7 19.9 24.4
Locked rotor amps 48 62.9 64 77 109 109 110
Condenser Fan Motor
Full load amps 0.6 0.8 0.8 0.8 1.2 1.2 1
Locked rotor amps 1.1 1.5 1.4 1.5 2.0 2.3 2.6
Line Voltage Data (Volts-Phase-Hz) — — — 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)² — — — 20 25 30 35
Minimum circuit ampacity³ — — — 13 16 18 21
Compressor
Rated load amps — — — 9 11.2 13.1 16
Locked rotor amps — — — 71 84 83.1 110
Condenser Fan Motor
Full load amps — — — 0.8 1.2 1.2 1
Locked rotor amps — — — 1.5 3.0 2.3 2.6
480-3-60 480-3-60
Line Voltage Data (Volts-Phase-Hz) — — — 480-3-60 480-3-60
RA1442AD RA1460CD
Maximum overcurrent protection (amps)² — — — 15 — 15 15
³Minimum circuit ampacity — — — 8 — 9 11
Compressor
Rated load amps — — — 5.6 — 6.1 7.8
Locked rotor amps — — — 38 — 41 60
Condenser Fan Motor
Full load amps — — — 0.5 — 0.6 0.5
Locked rotor amps — — — 1.1 — 1.6 1.4
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
7
Accessories/Weighted Sound Power
Air
RA14 Series
Accessories
Model No. RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460
Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45
Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Compressor time delay RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01
Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07
High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07
Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
(24 VAC, 50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
(120/240 VAC, 50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21
*Crankcase Heater recommended with Low Ambient Kit.
8
Unit Dimensions
Air
RA14 Series
Unit Dimensions
OPERATING SHIPPING
MODEL
H (Height) L (Length) W (Width) H (Height) L (Length) W (Width)
NO.
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RA1418 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822
RA1424 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822
RA1430 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822
RA1436 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924
RA1442 35 889 33.75 857 33.75 857 36.75 933 36.38 924 36.38 924
RA1448 31 787 35.75 908 35.75 908 32.75 832 38.38 975 38.38 975
RA1460 45 1143 35.75 908 35.75 908 45.38 1153 38.25 972 38.25 972
9
CLEARANCES
10
Air
WALL WALL
6⬙
Clearances
(152.4) 24⬙
RA14 Series
(609.6)
Service
(304.8) (304.8)
Service
6⬙
(152.4)
6⬙
(152.4)
12⬙
(304.8)
WALL
NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air.
ST-A1225-01-00
Wiring Diagram/Application Guidelines
Air
RA14 Series
Control Wiring
FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT
CONTROL WIRING FOR GAS OR OIL FURNACE W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER.
Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.
11
Refrigerant Line Size Information
13 - 16 SEER Single-Stage Air-Conditioners
12
Air
A/B W
1/4" 5/8" N/R N/R N/R N/R 25 / 1.00 50 / 0.99 62 / 0.98 43 / 0.98 24 / 0.97 5 / 0.97 N/R N/R N/R N/R
5/16" 5/8" N/R 223 198 188 25 / 1.00 50 / 0.99 75 / 0.98 98 / 0.98 93 / 0.97 88 / 0.97 83 / 0.96 78 / 0.96 73 / 0.95 68 / 0.94
1.5 Ton 3/8" 5/8" 178 148 132 125 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96 100 / 0.95 100 / 0.94
**SEE
NOTE 3 1/4" 3/4"** N/R N/R N/R N/R 25 / 1.00 50 / 1.00 62 / 0.99 43 / 0.99 24 / 0.99 5 / 0.99 N/R N/R N/R N/R
Refrigerant Line Size Information
5/16" 3/4"** N/R 223 198 188 25 / 1.00 50 / 1.00 75 / 0.99 98 / 0.99 93 / 0.99 88 / 0.99 83 / 0.99 78 / 0.98 73 / 0.98 68 / 0.98
3/8" 3/4"** 178 148 132 125 25 / 1.00 50 / 1.00 75 / 1.00 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 100 / 0.98 100 / 0.98
1/4" 5/8" N/R N/R N/R N/R 25 / 0.99 50 / 0.98 21 / 0.97 N/R N/R N/R N/R N/R N/R N/R
5/16" 5/8" 243 193 175 175 25 / 0.99 50 / 0.98 75 / 0.97 87 / 0.96 77 / 0.95 69 / 0.94 61 / 0.93 53 / 0.92 45 / 0.91 37 / 0.90
3/8" 5/8" 162 128 117 117 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 98 / 0.93 95 / 0.92 92 / 0.91 89 / 0.90
2 Ton
1/4" 3/4" N/R N/R N/R N/R 25 /1.00 50 / 1.00 21 / 0.99 N/R N/R N/R N/R N/R N/R N/R
5/16" 3/4" 243 193 175 175 25 /1.00 50 / 1.00 75 / 0.99 87 / 0.99 77 / 0.98 69 / 0.98 61 / 0.98 53 / 0.97 45 / 0.97 37 / 0.96
3/8" 3/4" 162 128 117 117 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.98 100 / 0.98 98 / 0.98 95 / 0.97 93 / 0.97 90 / 0.96
5/16" 5/8" N/R N/R 110 110 25 / 0.99 50 / 0.98 75 / 0.96 70 / 0.94 59 / 0.93 48 / 0.91 36 / 0.90 N/R N/R N/R
3/8" 5/8" 142 117 73 73 25 / 0.99 50 / 0.98 75 / 0.96 100 / 0.94 98 / 0.93 94 / 0.91 90 / 0.90 N/R N/R N/R
2.5 Ton
5/16" 3/4" 213 175 110 110 25 / 1.00 50 / 0.99 75 / 0.99 70 / 0.98 59 / 0.98 48 / 0.97 36 / 0.96 25 / 0.96 13 / 0.95 N/R
3/8" 3/4" 142 117 73 73 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 98 / 0.98 94 / 0.97 90 / 0.96 86 / 0.96 82 / 0.95 78 / 0.95
5/16" 5/8" N/R N/R N/R N/R 25 / 0.99 50 / 0.97 66 / 0.94 49 / 0.92 32 / 0.90 N/R N/R N/R N/R N/R
3/8" 5/8" 108 85 90 82 25 / 0.99 50 / 0.97 75 / 0.94 95 / 0.92 89 / 0.90 N/R N/R N/R N/R N/R
5/16" 3/4" N/R 128 135 123 25 / 1.00 50 / 0.99 66 / 0.98 49 / 0.98 32 / 0.97 15 / 0.96 N/R N/R N/R N/R
3/8" 3/4" 108 85 90 82 25 / 1.00 50 / 0.99 75 / 0.98 95 / 0.98 89 / 0.97 84 / 0.96 78 / 0.95 72 / 0.94 67 / 0.93 61 / 0.93
3 Ton
1/2" 3/4" 54 43 45 41 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.98 100 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.93 100 / 0.93
5/16" 7/8" N/R 128 135 123 25 / 1.00 50 / 1.00 66 / 1.00 49 / 0.99 32 / 0.99 15 / 0.99 N/R N/R N/R N/R
3/8" 7/8" 108 85 90 82 25 / 1.00 50 / 1.00 75 / 1.00 95 / 0.99 89 / 0.99 84 / 0.99 78 / 0.98 72 / 0.98 67 / 0.98 61 / 0.97
1/2" 7/8" 54 43 45 41 25 / 1.00 50 / 1.00 75 / 1.00 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 100 / 0.98 100 / 0.98 100 / 0.97
3/8" 3/4" 150 102 75 75 25 / 0.99 50 / 0.98 75 / 0.97 88 / 0.96 80 / 0.95 72 / 0.94 65 / 0.92 57 / 0.91 49 / 0.90 N/R
1/2" 3/4" 75 51 38 38 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.92 100 / 0.91 100 / 0.90 N/R
3.5 Ton
3/8" 7/8" 150 102 75 75 25 / 1.00 50 / 1.00 75 / 0.99 88 / 0.99 80 / 0.99 72 / 0.98 65 / 0.97 57 / 0.97 49 / 0.96 42 / 0.96
1/2" 7/8" 75 51 38 38 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96
NOTES:
1. Do not exceed 200 ft linear line length.
2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on size
Refrigerant Line Size Information (con’t.)
13 - 16 SEER Single-Stage Air-Conditioners
Apply Long Line Guidelines if Equivalent Length (Feet)
Allowable Allowable Linear Line Length Exceeds
Unit Size Liquid Line Suction Line Those Shown Below (Feet) < 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250
Size Size
(-)A14 (-)A14
(-)A13 (-)A16 Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier
A/B W
3/8" 3/4" 148 110 N/R 35 25 / 0.99 50 / 0.98 75 / 0.96 77 / 0.95 67 / 0.93 57 / 0.92 46 / 0.91 N/R N/R N/R
1/2" 3/4" 74 55 N/R 18 25 / 0.99 50 / 0.98 75 / 0.96 100 / 0.95 100 / 0.93 100 / 0.92 100 / 0.91 N/R N/R N/R
4 Ton
3/8" 7/8" 148 110 N/R 35 25 / 1.00 50 / 0.99 75 / 0.99 77 / 0.98 67 / 0.97 57 / 0.97 46 / 0.96 36 / 0.96 26 / 0.95 15 / 0.95
1/2" 7/8" 74 55 N/R 18 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96 99 / 0.95 97 / 0.95
3/8" 3/4" 78 0 N/R 0 25 / 0.99 50 / 0.97 75 / 0.94 61 / 0.92 46 / 0.90 N/R N/R N/R N/R N/R
1/2" 3/4" 39 0 N/R 0 25 / 0.99 50 / 0.97 75 / 0.94 100 / 0.92 100 / 0.90 N/R N/R N/R N/R N/R
3/8" 7/8" 78 0 N/R 0 25 / 1.00 50 / 0.99 75 / 0.98 61 / 0.97 46 / 0.96 32 / 0.95 18 / 0.94 N/R N/R N/R
5 Ton
1/2" 7/8" 39 0 N/R 0 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.97 100 /0.96 100 / 0.95 97 / 0.94 95 / 0.94 92 / 0.93 89 / 0.92
3/8" 1-1/8" 78 0 N/R 0 25 / 1.01 50 / 1.01 75 / 1.00 61 / 1.00 46 / 0.99 32 / 0.99 18 / 0.99 N/R N/R N/R
1/2" 1-1/8" 39 0 N/R 0 25 / 1.01 50 / 1.01 75 / 1.00 100 /1.00 100 / 0.99 100 / 0.99 97 / 0.99 95 / 0.99 92 / 0.99 89 / 0.98
NOTES:
1. Do not exceed 200 ft linear line length.
2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
3. **3/4" suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
NOTE: Values based on 105°F liquid temperature and 45°F evaporator temperature in cooling mode depending on size
Air
RA14 Series
13
Refrigerant Line Size Information
Refrigerant Line Size Information (con’t.)
13 - 16 SEER Single-Stage Air-Conditioners
14
Air
A/B W
6.35 [1/4] 15.88 [5/8] N/R N/R N/R N/R 8 / 1.00 15 / 0.99 19 / 0.98 13 / 0.98 7 / 0.97 2 / 0.97 N/R N/R N/R N/R
7.94 [5/16] 15.88 [5/8] N/R 68 60 57 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 28 / 0.97 27 / 0.97 25 / 0.96 24 / 0.96 22 / 0.95 21 / 0.94
5.3 KW
[1.5 Ton] 9.53 [3/8] 15.88 [5/8] 54 45 40 38 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30 / 0.97 30 / 0.96 30 / 0.96 30 / 0.95 30 / 0.94
**SEE 6.35 [1/4] **19.05 [3/4]** N/R N/R N/R N/R 8 / 1.00 15 / 1.00 19 / 0.99 13 / 0.99 7 / 0.99 2 / 0.99 N/R N/R N/R N/R
NOTE 3
7.94 [5/16] **19.05 [3/4]**
Refrigerant Line Size Information
N/R 68 60 57 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 28 / 0.99 27 / 0.99 25 / 0.99 24 / 0.98 22 / 0.98 21 / 0.98
9.53 [3/8] **19.05 [3/4]** 54 45 40 38 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98
6.35 [1/4] 15.88 [5/8] N/R N/R N/R N/R 8 / 0.99 15 / 0.98 6 / 0.97 N/R N/R N/R N/R N/R N/R N/R
7.94 [5/16] 15.88 [5/8] 74 59 53 53 8 / 0.99 15 / 0.98 23 / 0.97 27 / 0.96 23 / 0.95 21 / 0.94 19 / 0.93 16 / 0.92 14 / 0.91 11 / 0.90
7.0 KW 9.53 [3/8] 15.88 [5/8] 49 39 36 36 8 / 0.99 15 / 0.98 23 / 0.97 30 / 0.96 30 / 0.95 30 / 0.94 30 / 0.93 29 / 0.92 28 / 0.91 27 / 0.90
[2 Ton] 6.35 [1/4] 19.05 [3/4] N/R N/R N/R N/R 8 / 1.00 15 / 1.00 6 / 0.99 N/R N/R N/R N/R N/R N/R N/R
7.94 [5/16] 19.05 [3/4] 74 59 53 53 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 23 / 0.98 21 / 0.98 19 / 0.98 16 / 0.97 14 / 0.97 11 / 0.96
9.53 [3/8] 19.05 [3/4] 49 39 36 36 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 29 / 0.97 28 / 0.97 27 / 0.96
7.94 [5/16] 15.88 [5/8] N/R N/R 34 34 8 / 0.99 15 / 0.98 23 / 0.96 21 / 0.94 18 / 0.93 15 / 0.91 11 / 0.90 N/R N/R N/R
8.8 KW 9.53 [3/8] 15.88 [5/8] 43 36 22 22 8 / 0.99 15 / 0.98 23 / 0.96 30 / 0.94 30 / 0.93 29 / 0.91 27 / 0.90 N/R N/R N/R
[2.5 Ton] 7.94 [5/16] 19.05 [3/4] 65 53 34 34 8 / 1.00 15 / 0.99 23 / 0.99 21 / 0.98 18 / 0.98 15 / 0.97 11 / 0.96 8 / 0.96 4 / 0.95 N/R
9.53 [3/8] 19.05 [3/4] 43 36 22 22 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.98 29 / 0.97 27 / 0.96 26 / 0.96 25 / 0.95 24 / 0.95
7.94 [5/16] 15.88 [5/8] N/R N/R N/R N/R 8 / 0.99 15 / 0.97 20 / 0.94 15 / 0.92 10 / 0.90 N/R N/R N/R N/R N/R
9.53 [3/8] 15.88 [5/8] 33 26 27 25 8 / 0.99 15 / 0.97 23 / 0.94 29 / 0.92 27 / 0.90 N/R N/R N/R N/R N/R
7.94 [5/16] 19.05 [3/4] N/R 39 41 37 8 / 1.00 15 / 0.99 20 / 0.98 15 / 0.98 10 / 0.97 5 / 0.96 N/R N/R N/R N/R
10.6 KW 9.53 [3/8] 19.05 [3/4] 33 26 27 25 8 / 1.00 15 / 0.99 23 / 0.98 29 / 0.98 27 / 0.97 26 / 0.96 24 / 0.95 22 / 0.94 20 / 0.93 19 / 0.93
[3 Ton] 12.70 [1/2] 19.05 [3/4] 17 13 14 12 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30 / 0.96 30 / 0.95 30 / 0.94 30 / 0.93 30 / 0.93
7.94 [5/16] 22.23 [7/8] N/R 39 41 37 8 / 1.00 15 / 1.00 20 / 1.00 15 / 0.99 10 / 0.99 5 / 0.99 N/R N/R N/R N/R
9.53 [3/8] 22.23 [7/8] 33 26 27 25 8 / 1.00 15 / 1.00 23 / 1.00 29 / 0.99 27 / 0.99 26 / 0.99 24 / 0.98 22 / 0.98 20 / 0.98 19 / 0.97
12.70 [1/2] 22.23 [7/8] 17 13 14 12 8 / 1.00 15 / 1.00 23 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 30 / 0.97
9.53 [3/8] 19.05 [3/4] 46 31 23 23 8 / 0.99 15 / 0.98 23 / 0.97 27 / 0.96 24 / 0.95 22 / 0.94 20 / 0.92 17 / 0.91 15 / 0.90 N/R
12.3 KW 12.70 [1/2] 19.05 [3/4] 23 15 11 11 8 / 0.99 15 / 0.98 23 / 0.97 30 / 0.96 30 / 0.95 30 / 0.94 30 / 0.92 30 / 0.91 30 / 0.90 N/R
[3.5 Ton] 9.53 [3/8] 22.23 [7/8] 46 31 23 23 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 24 / 0.99 22 / 0.98 20 / 0.97 17 / 0.97 15 / 0.96 13 / 0.96
12.70 [1/2] 22.23 [7/8] 23 15 11 11 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.97 30 / 0.97 30 / 0.96 30 / 0.96
NOTES:
1. Do not exceed 61 meters linear line length.
2. *Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit.
3. **19.05 mm [3/4 in.] suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
4. Always use the smallest liquid line allowable to minimize refrigerant charge.
5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
15
Refrigerant Line Size Information
Performance Data
Air
RA14 Series
16
Guide Specifications
Air
RA14 Series
GUIDE SPECIFICATIONS
General AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER
System Description RA14
Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS
posite base pan unit suitable for ground or rooftop installation. Fans
Unit consists of a hermetic compressor, an air-cooled coil, pro- — Condenser fan will be direct-drive propeller type, discharging
peller-type condenser fan, suction and legend line service valve, air upward.
and a control box. Unit will discharge supply air upward as shown — Condenser fan motors will be totally enclosed, 1-phase type
on contract drawings. Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings.
match up to a coil unit. Shafts will be corrosion resistant.
Quality Assurance — Fan blades will be statically and dynamically balanced.
— Unit will be rated in accordance with the latest edition of AHRI — Condenser fan openings will be equipped with coated steel
Standard 210. wire safety guards.
— Unit will be certified for capacity and efficiency, and listed in Compressor
the latest AHRI directory.
— Compressor will be hermetically sealed.
— Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC. — Compressor will be mounted on rubber vibration isolators.
— Unit will be constructed in accordance with UL standards and Condenser Coil
will carry the UL label of approval. Unit will have c-UL-us — Condenser coil will be air cooled.
approval. — Coil will be constructed of aluminum fins mechanically bonded
— Unit cabinet will be capable of withstanding ASTM B117 1000- to copper tubes.
hr salt spray test. Refrigeration Components
— Air-cooled condenser coils will be leak tested at 150 psig and — Refrigeration circuit components will include liquid-line shutoff
pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with
— Unit constructed in ISO9001 approved facility. sweat connections, system charge of R-410A refrigerant, and
compressor oil.
Delivery, Storage, and Handling
— Unit will be equipped with filter drier for R-410A refrigerant for
— Unit will be shipped as single package only and is stored and
field installation.
handled per unit manufacturer’s recommendations.
Operating Characteristics
Warranty (for inclusion by specifying engineer) — U.S. and
Canada only. — The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F/°C. The power consumption
at full load will not exceed _____ kW.
Products — Combination of the unit and the evaporator or fan coil unit will
Equipment have a total net cooling capacity of _____ Btuh or greater at
Factory assembled, single piece, air-cooled air conditioner unit. conditions of _____ CFM entering air temperature at the evap-
Contained within the unit enclosure is all factory wiring, piping, orator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and
controls, compressor, refrigerant charge R-410A, and special fea- air entering the unit at _____ °F/°C.
tures required prior to field start-up.
— The system will have a SEER of _____ Btuh/watt or greater at
Unit Cabinet DOE conditions.
— Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements
ized, and coated with a powder coat paint.
— Nominal unit electrical characteristics will be _____ v, single
— All units constructed with louver coil protection and corner post. phase, 60 hz. The unit will be capable of satisfactory operation
Louver can be removed by removing one fastener per louver within voltage limits of _____ v to _____ v.
panel.
— Nominal unit electrical characteristics will be _____ v, three
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories and
descriptions for specific features and available enhancements.
17
Limited Warranty
Air
RA14 Series
18
Notes
Air
RA14 Series
19
The new degree of comfort.™
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1