Adcom Gfa-5300 SM
Adcom Gfa-5300 SM
2 CHANNEL
POWER AMPLIFIER
GFA-5300
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . 1
Test Procedures . . . . . . . . . . . . . 1
Parts List . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . 5
Chassis Layout . . . . . . . . . . . . . . . 5
PCB Layout . . . . . . . . . . . . . . . . . . 7
Wiring Diagram. . . . . . . . . . . . . . . . 8
Schematic . . . . . . . . . . . . . . . . . 9
10 Timber Lane
Marlboro, NJ 07746
USA
Tel: 732-683-2356
Fax: 732-683-9790
Web: http://www.adcom.com
INTRODUCTION
This service manual is intended to assist trained and qualified technical personnel in verifying the
performance of, adjusting, and repairing the ADCOM GFA-5300 amplifier. The procedures described here
are not intended for persons unfamiliar with the appropriate safety and test procedures.
WARNING
THERE ARE POTENTIALLY LETHAL VOLTAGES WITHIN THE GFA-5300 AMPLIFIER WHICH WILL
BE ACCESSIBLE ONCE ITS TOP COVER IS REMOVED. DO NOT ATTEMPT FAMILIARIZATION,
INSPECTION, OR ANY PROCEDURE WHATSOEVER UNLESS YOU HAVE DISCONNECTED THE
GFA-5300 FROM THE WALL AC OUTLET OR OTHER SOURCE OF AC POWER AND THE
POWER-SUPPLY CAPACITORS ARE COMPLETELY DISCHARGED. THESE INSTRUCTIONS ARE
PROVIDED FOR USE ONLY BY COMPETENT TECHNICAL PERSONNEL. DO NOT UNDERTAKE
ANY SERVICE PROCEDURES IN THE GFA-5300 UNLESS YOU ARE TECHNICALLY QUALIFIED TO
DO SO.
TEST PROCEDURES
• All tests are performed with a 115V, low-distortion (less than 2% THD), AC-power source, 8-ohm
resistive load (except slew rate), and a signal source of not more than 600 ohms.
• An 80kHz low-pass filter is employed during THD distortion measurements.
• Signal-to-noise measurements are “A” weighted.
• Damping factor is measured by comparing the 1 watt output voltage with and without an 8 ohm load.
• Slew rate is measured with an inductive load, and is derived with a dual-time-based oscilloscope
reading the slope of a full power 5kHz square wave. DO NOT OPERATE THE AMPLIFIER AT
FULL-POWER SINE WAVE ABOVE 22kHz OR FULL-POWER SQUARE WAVE ABOVE 5kHz.
IMPORTANT
BEFORE PROCEEDING WITH ADJUSTMENTS, MAKE SURE AMPLIFIER IS AT ROOM
TEMPERATURE.
BIAS ALIGNMENT
Prior to performing BIAS ALIGNMENT turn unit on and allow to idle with rated output (8 ohm) for
approximately 5 MINUTES before attempting adjustments
Bias Adjustment
Connect voltmeter across emitter resister R038 (R138 for right channel) and adjust R043 (R143 for right
channel) to read 20mV +/-2mV
DC Offset
Connect voltmeter across the speaker outputs and adjust R042 (R142 for right channel) to read 0mV +/-
10mV
1
a GFA-5300 SERVICE PARTS LIST
AMPLIFIER PCB
FOR RIGHT CHANNEL REPLACE 0XX WITH 1XX
2
R007 27004670 RESISTOR 100R
3
MAIN AND STANDBY POWER SUPPLY PCB
OTHERS
4
a GFA-5300 VOLTAGE CONVERSION
Certain versions of the GFA-5300 are cabable of operating at multiple voltages.The conversion
described below is for multivoltage versions of the GFA-5300. Multivoltage versions of the GFA-5300
have removable power cords.
1) With the Unit unplugged, remove the top cover of the GFA-5300.
2) Locate the Power and Standby PCBs at the front of the unit (pictured below).
3) Remove jumpers J201, J202, J204 and J205.
4) Add jumpers J203 and J206.
5) Replace the rear panel 6A main fuse with a 3A fuse.
6) Add sticker to back of unit indicating new operating voltage and fuse rating.
7) Replace top cover and test on 230VAC source.
1) With the unit unplugged, remove the top cover of the GFA-5300.
2) Locate the Power and Standby PCBs at the front of the unit (pictured below).
3) Remove jumpers J203 and J206.
4) Add jumpers J201, J202, J204 and J205.
5) Replace the rear panel 3A main fuse with a 6A fuse.
6) Add sticker to back of unit indicating new operating voltage and fuse rating.
7) Replace top cover and test on 115VAC source.
J203
J202
J201
J206
J205
J204
5
GFA-5300 SPECIFICATIONS
Power Rating (To FTC Requirements)
80 watts continuous average power per channel into 8 ohms at any frequency between 20Hz to 20kHz with
all channels driven at less than 0.18% THD
125 watts continuous average power per channel into 4 ohms at any frequency between 20Hz to 20kHz with
all channels driven at less than 0.18% THD
IM Distortion (SMPTE)
1 watt to 80 watts into 8 ohms ..................................................................................................................................... ≤ 0.07%
1 watt to 125 watts into 4 ohms ................................................................................................................................... ≤ 0.07%
Signal to Noise Ratio, “A” Weighted (80 watts into 8 ohms).......................................................................................... ≥ 100dB
Input Sensitivity
for 1 Watt ...................................................................................................................................................................... 0.1 volts
for 80 Watts .................................................................................................................................................................. 0.9 volts
Rise Time (5kHz, 90V, peak-to-peak square wave, 20% to 80%)....................................................................................... 1.8µS