Name : SUMBONG, ARVIN JAY Marks :

Course, Year & : BET-ET-3A Date : 9/29/24


Section

1. A shunt generator supplies a load of 5,500 W at 110 V through a pair of feeder conductors
having a resistance of 0.02 ohm each. The armature, shunt field resistances are 0.15 ohm and 50
ohms respectively. Find the generated emf.

2. The no load voltage of a 50 kW, 220 volts, shunt generator in TUP laboratory is 232 volts and the
rated load voltage is 220 volts. The armature resistance including brushes is 0.026 ohm and the
resistance of the shunt field resistance is 53 ohms. What is the induced electromagnetic force at
rated load?

3. The field current of a 180 kW, 250 volts DC shunt generator is 6A when running full load at rated
terminal voltage. If the combined armature and brush resistance is 0.02 ohm solve for the
power generated.

4. A DC generator has no load output voltage of 120 volts. Its armature circuit resistance is 0.95
ohm, and its field coils are separately energized. If the load is rated 2 kW at 115 V. Neglecting
the effect of armature reaction, what power could be delivered to the load?

5. A DC series generator is supplying current of 5A to a series lighting system through a feeder of


total resistance, 1.0 ohm. The terminal voltage is 2500 V. The armature and series field
resistances are respectively 18 and 15 ohms. A 30-ohm diverter resistance is shunted across the
series field. Determine the power developed in the armature generator.

6. A compound dynamo supplies a load of 20 kW at 400 V through a feeder having a resistance


equal to 0.1 ohm. The shunt and series field resistances are 65 ohms and 0.06 ohm respectively.
Determine the total electromotive force when the generator is connected long shunt. Assume a
brush contact drop of 1 V per brush and armature resistance of 0.1 ohm.

7. A long shunt compound generator has the following parameters:


a. Ra = 0.1 ohm
b. Rse = 0.05 ohm
c. Rsh = 120 ohms

This machine supplies power aggregate DC load of 10 kW, at this load the armature generates
246 volts. Determine the terminal voltage.

8. A short shunt compound generator has the following: an armature, series field and shunt field
resistances are 0.04-ohm, 0.03 ohm and 80 ohms respectively. The generator serves a 20 kW,
200 V load through a feeder with an equivalent resistance of 0.1 ohm. Solve for the power
generated by the armature.
9. A short shunt compound generator has an armature, shunt field and series field resistances of
0.02-ohm, 80 ohm and 0.03 ohm respectively. The generator’s induced emf is 510 V when the
terminal voltage is 500 V. How much load current is delivered under this condition?

10. A short shunt compound generator delivers 150 A at a terminal voltage is 230 V. The shunt field
current is 2.5 A. The resistances of the armature, series field and diverter are 0.032 ohm, 0.015
ohm and 0.03 ohm, respectively. Calculate the generated power.