Manual de equipo

DWEB006
1
Página

Atualização Jul/2021
Sumário
Apresentação ....................................................................................................... Erro! Indicador não definido.
Conectividade ................................................................................................................................................ 4
Hardware........................................................................................................................................................ 5
Diagrama das Conexões ..................................................................................................................................... 6
Terminais de Conexões Externas.......................................................................... Erro! Indicador não definido.
Conexões Internas ................................................................................................ Erro! Indicador não definido.
Jump’s do lado inferior da placa ² .................................................................................................................. 9
Configuração e Operação das Entradas Digitais[¹] ............................................... Erro! Indicador não definido.

2
Página

Atualização Jul/2021
PRESENTACIÓN
El equipo DWEB006 permite un amplio campo de usos para tomar datos y control de
equipos y, mediante la integración con la plataforma DEMANDAWEB, monitoreo,
parametrización, envío de alarmas, análisis, generación de reportes, gráficos, etc.

Permite colectar información de sensores de temperatura, caudal de agua, gas, presión,


pulso, estado de información digital y otros, además de equipos estándar MODBUS
como PLC, etc..

El DWEB006 dispone de conexión de red 10/100 ETHERNET además de conexión Wi-Fi


de 2,4 ghz, lo que facilita la instalación, eliminando la necesidad de cables de red.

Dispone de una página WEB interna para configurar los parámetros de conexión al
punto de acceso.

Con entrada de alimentación de CA o CC de 100 a 240 voltios, cumple con la mayoría


de los requisitos de alimentación.

Dispone de 2 entradas independientes, que se pueden utilizar de dos formas:

 En modo PULSO, está indicado para la conexión a equipos de medida que utilicen
este tipo de sensor, como contadores de agua, gas, aire comprimido, etc. Pueden
configurarse para la medida directa de equipos que suministren una tensión
continua superior a 12 Voltios hasta 48 Voltios o que utilicen un sistema de
"colector abierto", con alimentación externa o interna, y en el caso de la fuente
de alimentación interna, la tensión es 5 Voltios suministrados por el propio
equipo.

 En modo DIGITAL las entradas pueden recibir desde 80 voltios hasta 240 voltios
CA o CC y son ideales para monitorear energía, como presencia o caída de voltaje,
si el generador está encendido, etc. o también si un interruptor está abierto o
3

cerrado. Como ejemplo podemos mencionar el contacto de un relé o contactor,


Página

sensor de puerta, etc.

Nota: Para más detalles consultar las opciones en la tabla CONFIGURACIÓN Y


FUNCIONAMIENTO DE LAS ENTRADAS DIGITALES[¹]

Atualização Jul/2021
La entrada ONEWIRE en el estándar MicroLan permite la conexión de accesorios
compatibles, como sensores de temperatura, permitiendo la conexión de varios
sensores en una misma entrada.

Utilizando el sensor de temperatura, suministrado como accesorio, fabricado en acero


inoxidable e impermeable, permite la lectura de temperaturas entre -55°C a 125°C (-
67°F a 257°F) con una precisión de ±0,5°C en el rango de -10 a +85°C y un tiempo de
consulta inferior a 750ms es ideal para monitorear cámaras frigoríficas, aire
acondicionado central, sótanos, refrigeradores para almacenamiento de vacunas, etc.

Con la conexión RS485-MODBUS bidireccional (https://modbus.org/) es posible


comunicarse a una distancia de hasta 1200 metros, utilizando solo 1 par metálico, lo
que aplica su uso a una amplia gama de equipos que utilizan este estándar como PLC's,
relé de seguridad para cabina primaria, multímetros, etc.

La entrada para SENSOR DE DISTANCIA, o nivel de líquido por ultrasonidos permite


monitorear el nivel de líquidos (no agresivos) como el nivel de tanques de agua o la
distancia de hasta 3 metros entre el sensor y la mampara, como ejemplo se puede
utilizar en sustitución del bucle inductivo utilizado para la detección de vehículos.

Dispone de un relé con contactos Común/NA/NC con capacidad de hasta 1A que puede
ser activado internamente o vía WEB.

Conectividad

• 1 conexión de red ETHERNET 10/100 y Wi-Fi 2,4 ghz


• 1 conexión de relé que puede ser NC o NA
• 2 entradas de pulsos independientes que también se pueden utilizar como entradas
digitales de CA o CC
• 1 entrada ONEWIRE para accesorios compatibles (temperatura, etc)
• 1 Conexión bidireccional RS485 MODBUS fotoaislada
• 1 Conexión para módulo de expansión DW-CODI
4
Página

• 1 Entrada para sensor de distancia o nivel de líquido ultrasónico


• Entrada de alimentación de CA o CC de 100 a 240 voltios (CC opcional de 10 a 18
voltios)

Atualização Jul/2021
Hardware
Processador: Allwiner H5

 CPU: Quad-Core ARM Cortex-A53


 Memory: 512 MB DDR3 SDRAM
 GPU: Mali450 MP4
 Onboard Storage: TF card (Max. 32GB) / Spi flash(2MB)
 Wifi: Realtek RTL8189FTV, IEEE 802.11 b/g/n
 Network: 1000M/100M/10M Ethernet RJ45
 USB: One USB 2.0 HOST, One USB 2.0 OTG
 RTC: Real Time Clock (externo)

Microcontrolador: 1 x ATMega328P

 8 Bit microcontroller
 32K flash memory
 16Mz speed clock / 20 MIPS/DMIPS
 2K SRAM
 EPROM 1K
 1 UART
 2 SPI
 1 I2C
 3 Timers – 2x8bit, 1x16bit

5
Página

Atualização Jul/2021
DIAGRAMA DE CONEXIÓNES

6
Página

Atualização Jul/2021
TERMINALES DE CONEXIÓN EXTERNAS
1 a 3 - Conexión para rele
1 - Contacto comum do RELE
2 - Contacto NF
3 - Contacto NA

4 a 6 - Entrada ONEWIRE para acessórios compatíbles (temperatura, etc.)


4 - Negativo del sensor
5 - Siñal del sensor
6 - Positivo del sensor

7 e 8 - entrada digital 1 (estándar de producción) o pulso Nota - Consultar otras opciones en


la tabla CONFIGURACIÓN Y FUNCIONAMIENTO DE LAS ENTRADAS DIGITALES[¹]
7 - Negativo
8 - Positivo

9 e 10 - entrada digital 2 (estándar de producción) o pulso Nota - Consultar otras opciones


en la tabla CONFIGURACIÓN Y FUNCIONAMIENTO DE LAS ENTRADAS DIGITALES[¹]
9 - Negativo
10 - Positivo

11 a 13 - Conexión bidirecional RS485 MODBUS foto aisolado


11 - G
12 - B-
13 - A

14 e 15 - Entrada de energía: CA o CC de 100 a 240 voltios (estándar de producción) o CC de


10 a 18 voltios
14 - AC1
15 - AC2
7

15 - DC Negativo (jump G1 ligado)²


Página

16 - DC Positivo (jump 5V ligado)²

Atualização Jul/2021
CONEXIONES INTERNAS
BAT: Conexión para la bateria CR2032 3V - backup del RTC (Real Time Clock)
1 - GND
2 - +POSITIVO BATERIA

SPIA: Conexión al módulo de expansión DW-CODI u otros accesorios compatibles con el


estándar SPI
1 - VCC 5 Volts
2 – MOSI
3 – SCK
4 – MISO
5 – SS
6 - GND

I2C: Conexión para accesorios compatibles con el estándar SPI


1 - 12 Volts
2 - VCC 5 Volts
3 - SDA
4 - SCL
5 - GND

LORA: Conexión para accesorios compatibles con el estándar LoRa/SPI


1 - PA02
2 - 3V3
3 - PA06
4 - GND

SPI0: Conexión para accesorios compatibles con el estándar LoRa/SPI


1 - CLK1
2 - MISO1
3 - MOSI1
4 - SS
8

DISTANCE: Entrada para sensor de distancia o nivel de líquido ultrasónico


Página

1 - VCC 5 Volts
2 - ECHO
3 - TRIGGER
4 - GND

Atualização Jul/2021
BUZZ: Conexión para zumbador
1 - POSITIVO DEL BUZZER
2 – GND

MB: Selección para conectar MODBUS al procesador


1 + 2 - Estándar de producción
5 + 6 - Estándar de producción

FAN: Conexión para el ventilador de 5 voltios


1 - POSITIVO DEL COOLER
2 - NEGATIVO DEL COOLER

PORG: Conector de alimentación para el procesador principal, este conector se alimenta a


través del relé WDOG-RLY en estado normalmente cerrado
1 - GND
2 - POSITIVO DEL PROCESSADOR PRINCIPAL

P1 e P2: Consultar la tabla de CONFIGURACIÓN Y FUNCIONAMIENTO DE LAS ENTRADAS


DIGITALES¹

Nota estándar de producción sin ningun JUMP

JUMP´s en la parte inferior²


G1 - 5V - 12V: Cuando se usan con la mini fuente interna (estándar de producción) deben estar
abiertos, cuando se usan con una fuente externa deben estar cerrados.

9
Página

Atualização Jul/2021
CONFIGURACIÓN Y FUNCIONAMIENTO
DE ENTRADAS DIGITALES[¹]
DC (5 Vcc a 24Vcc) DC (80Vcc a 230Vcc) AC (80Vca a 230Vca)

Entrada digital 1 : Entrada digital 1: Entrada digital 1:


P1 - todos abiertos P1 - todos abiertos P1 - todos abiertos
P1 - todos abiertos P1 - todos abiertos P1 - todos abiertos
P1 - todos abiertos P1 - todos abiertos 3+6 - conectado
P1 - todos abiertos P1 - todos abiertos P1 - todos abiertos
R20 (4K7) conectado R20 (4K7) desconectado R20 (4K7) desconectado

Entrada digital 2: Entrada digital 2: Entrada digital 2:


P2 - todos abiertos P2 - todos abiertos P2 - todos abiertos
P2 - todos abiertos P2 - todos abiertos P2 - todos abiertos
P2 - todos abiertos P2 - todos abiertos 3+6 - fechado
P2 - todos abiertos P2 - todos abiertos P2 - todos abiertos
R25 (4K7) conectado R25 (4K7) desconectado R25 (4K7) desconectad

(atención a la polaridad) (atención a la polaridad)


Open colector (DC 5 Vcc) Open colector
(DC interno 5 Vcc) (DC Externo 5 Vcc a 24Vcc)

Entrada digital 1 : Entrada digital 1 :


P1 - 1+8 fechado P1 - 1 e 8 aberto
P1 - 2+7 fechado P1 - 2 e 7 aberto
P1 - 3 e 6 aberto P1 - 3 e 6 aberto
P1 - 4+5 fechado P1 - 4 e 5 aberto
R25 (4K7) conectado
Entrada digital 2:
P2 - 1+8 fechado Entrada digital 2:
P2 - 2+7 fechado P2 - 1 e 8 aberto
P2 - 2 e 7 aberto
10

P2 - 3 e 6 aberto
P2 - 4+5 conectado P2 - 3 e 6 aberto
Página

P2 - 4 e 5 aberto
(atención a la polaridad) R25 (4K7) conectado

* (vcc) Alimentación externa

Atualização Jul/2021
www.demandaweb.com.br
[email protected]
(11) 2626-5152

11
Página

Atualização Jul/2021