EC 16 & DEX16 User Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

USER MANUAL

Elevator Control Panel &


Elevator Floor Extension Board
Applicable Models: EC16 & DEX16
Version: 1.1

Date: March 2023

English

Thank you for choosing our product. Please read the instructions carefully
before operation. Follow these instructions to ensure that the product is
functioning properly. The images shown in this manual are for illustrative
purposes only.

For further details, please visit our Company’s website


www.zkteco.com.
EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Copyright © 2023 ZKTECO CO., LTD. All rights reserved.


Without the prior written consent of ZKTeco, no terminalion of this manual can be copied or forwarded
in any way or form. All parts of this manual belong to ZKTeco and its subsidiaries (hereinafter the
"Company" or "ZKTeco").

Trademark
is a registered trademark of ZKTeco. Other trademarks involved in this manual are owned
by their respective owners.

Disclaimer
This manual contains information on the operation and maintenance of the ZKTeco equipment. The
copyright in all the documents, drawings, etc. in relation to the ZKTeco supplied equipment vests in
and is the property of ZKTeco. The contents hereof should not be used or shared by the receiver with
any third party without the express written permission of ZKTeco.

The contents of this manual must be read as a whole before starting the operation and maintenance of
the supplied equipment. If any of the content(s) of the manual seems unclear or incomplete, please
contact ZKTeco before starting the operation and maintenance of the said equipment.

It is an essential pre-requisite for the satisfactory operation and maintenance that the operating and
maintenance personnel are fully familiar with the design and that the said personnel have received
thorough training in operating and maintaining the machine/unit/equipment. It is further essential for
the safe operation of the machine/unit/equipment that personnel has read, understood and followed
the safety instructions contained in the manual.

In case of any conflict between terms and conditions of this manual and the contract specifications,
drawings, instruction sheets or any other contract-related documents, the contract conditions/
documents shall prevail. The contract specific conditions/documents shall apply in priority.

ZKTeco offers no warranty, guarantee or representation regarding the completeness of any


information contained in this manual or any of the amendments made thereto. ZKTeco does not
extend the warranty of any kind, including, without limitation, any warranty of design, merchantability
or fitness for a particular purpose.

ZKTeco does not assume responsibility for any errors or omissions in the information or documents
which are referenced by or linked to this manual. The entire risk as to the results and performance
obtained from using the information is assumed by the user.

ZKTeco in no event shall be liable to the user or any third party for any incidental, consequential,
indirect, special, or exemplary damages, including, without limitation, loss of business, loss of profits,
business interruption, loss of business information or any pecuniary loss, arising out of, in connection
with, or relating to the use of the information contained in or referenced by this manual, even if
ZKTeco has been advised of the possibility of such damages.

This manual and the information contained therein may include technical, other inaccuracies or
typographical errors. ZKTeco periodically changes the information herein which will be incorporated
into new additions/amendments to the manual. ZKTeco reserves the right to add, delete, amend or
modify the information contained in the manual from time to time in the form of circulars, letters,
notes, etc. for better operation and safety of the machine/unit/equipment. The said additions or

P a g e |1 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

amendments are meant for improvement /better operations of the machine/unit/equipment and such
amendments shall not give any right to claim any compensation or damages under any circumstances.

ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions due to any
non-compliance of the instructions contained in this manual (ii) in case of operation of the
machine/unit/equipment beyond the rate limits (iii) in case of operation of the machine and
equipment in conditions different from the prescribed conditions of the manual.

The product will be updated from time to time without prior notice. The latest operation procedures
and relevant documents are available on http://www.zkteco.com.

If there is any issue related to the product, please contact us.

ZKTeco Headquarters
Address ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town, Dongguan, China.

Phone +86 769 - 82109991

Fax +86 755 - 89602394

For business-related queries, please write to us at [email protected].

To know more about our global branches, visit www.zkteco.com.

P a g e |2 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

About the Company


ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-
vein) readers. Product offerings include Access Control readers and panels, Near & Far-range Facial
Recognition Cameras, Elevator/floor access controllers, Turnstiles, License Plate Recognition (LPR) gate
controllers and Consumer products including battery-operated fingerprint and face-reader Door Locks.
Our security solutions are multi-lingual and localized in over 18 different languages. At the ZKTeco
state-of-the-art 700,000 square foot ISO9001-certified manufacturing facility, we control manufacturing,
product design, component assembly, and logistics/shipping, all under one roof.

The founders of ZKTeco have been determined for independent research and development of
biometric verification procedures and the productization of biometric verification SDK, which was
initially widely applied in PC security and identity authentication fields. With the continuous
enhancement of the development and plenty of market applications, the team has gradually
constructed an identity authentication ecosystem and smart security ecosystem, which are based on
biometric verification techniques. With years of experience in the industrialization of biometric
verifications, ZKTeco was officially established in 2007 and now has been one of the globally leading
enterprises in the biometric verification industry owning various patents and being selected as the
National High-tech Enterprise for 6 consecutive years. Its products are protected by intellectual
property rights.

About the Manual


This manual introduces the operations of EC16 Elevator Control Panel & DEX16 Elevator Floor
Extension Board.

All figures displayed are for illustration purposes only. Figures in this manual may not be exactly
consistent with the actual products.

Features and parameters with ★ are not available in all devices.

P a g e |3 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Document Conventions
Conventions used in this manual are listed below:
GUI Conventions

For Software

Convention Description

Bold font Used to identify software interface names e.g., OK, Confirm, Cancel.

Multi-level menus are separated by these brackets. For example, File >
>
Create > Folder.

For Device

Convention Description

<> Button or key names for devices. For example, press <OK>.

Window names, menu items, data table, and field names are inside square
[]
brackets. For example, pop up the [New User] window.

Multi-level menus are separated by forwarding slashes. For example,


/
[File/Create/Folder].

Symbols

Convention Description

This represents a note that needs to pay more attention to.

The general information which helps in performing the operations faster.

The information which is significant.

Care taken to avoid danger or mistakes.

The statement or event that warns of something or that serves as a cautionary


example.

P a g e |4 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Table of Contents
1 SAFETY INSTRUCTIONS ....................................................................................................................... 7
IMPORTANT SECURITY INSTRUCTIONS ...............................................................................................................................7
INSTALLATION CAUTIONS ...................................................................................................................................................8
2 OVERVIEW ............................................................................................................................................ 9
SYSTEM INTRODUCTION ..................................................................................................................................................... 9
PACKAGE C ENCLOSURE INTRODUCTION ......................................................................................................................... 9
SYSTEM EQUIPMENT COMPOSITION ............................................................................................................................... 10
TECHNICAL PARAMETERS .................................................................................................................................................11
LED INDICATORS DESCRIPTION ......................................................................................................................................12
3 TERMINAL INSTRUCTIONS ................................................................................................................ 13
4 WIRING DESCRIPTION ........................................................................................................................15
ELEVATOR CONTROLLER NETWORKING CABLING ..........................................................................................................15
CONNECTION POWER SUPPLY ........................................................................................................................................ 16
ETHERNET CONNECTION TO THE COMPUTER ................................................................................................................ 17
ELEVATOR CONTROL AND ELEVATOR BUTTON WIRING ............................................................................................... 18
MO, EMG, FIRE, TAMPER INTERFACE DESCRIPTION ................................................................................................19
WIRING OF EXPANSION BOARD ...................................................................................................................................... 21
INSTALLATION OF ELEVATOR MANAGEMENT SYSTEM ..................................................................................................22
ELEVATOR CONTROLLER SYSTEM POWER SUPPLY STRUCTURE ................................................................................... 23
5 ELEVATOR CONTROL OPERATING INSTRUCTIONS ......................................................................... 24
CONNECT TO ZKBIO CVSECURITY SOFTWARE ..............................................................................................................24
5.1.1 LOGIN SOFTWARE ................................................................................................................................................ 24
5.1.2 ADD DEVICE ON THE SOFTWARE ........................................................................................................................25
5.1.3 SYNCHRONIZE ALL DATA TO DEVICES ...............................................................................................................26
5.1.4 ADD EXPANSION BOARD ON THE SOFTWARE ...................................................................................................27
5.1.5 ADD READER ON THE SOFTWARE .......................................................................................................................28
5.1.6 SET ELEVATOR CONTROL RULES ON SOFTWARE .............................................................................................. 30
USER VERIFICATION ON THE QR-600 SERIES READERS ............................................................................................... 35
CONNECT TO ZKBIOSECURITY MOBILE APP ................................................................................................................. 35
5.3.1 MOBILE APP CONFIGURATION ............................................................................................................................35
5.3.2 LOGIN ....................................................................................................................................................................37
5.3.3 ENABLE THE DYNAMIC QR CODE ON THE SOFTWARE .....................................................................................39

P a g e |5 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.3.4 VERIFICATION QR CODE ..................................................................................................................................... 40


6 COMMUNICATION CONNECTION ..................................................................................................... 41
ACCESS CONTROL NETWORKING WIRES AND WIRING .................................................................................................41
TCP/IP COMMUNICATION .............................................................................................................................................. 42
MODIFY THE IP ADDRESS ................................................................................................................................................ 43
7 OTHERS ............................................................................................................................................... 46
USB DISK UPGRADE ........................................................................................................................................................46
RESTORE FACTORY SETTINGS ..........................................................................................................................................46
APPENDIX 1 BUZZER, INDICATOR LIGHT PROMPT INSTRUCTIONS ..................................................47
APPENDIX 2 PRIVACY POLICY ..............................................................................................................48
APPENDIX 3 ECO-FRIENDLY OPERATION ........................................................................................... 50

P a g e |6 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

1 Safety Instructions

Important Security Instructions

1. Before operating the equipment, please read and strictly follow all security and operation instructions.
Please keep the instructions in good condition for future reference.
2. Please use the accessories recommended by the manufacturer or delivered together with the
product. Any other related product is not recommended to be used as the alarm or monitoring
system (cameras, infrared detectors, smoke detectors, etc.). The alarm or monitoring system
should comply with the local applicable fire-prevention and security standards.
3. Do not place this equipment on any unstable table, tripod mount, supterminal or base to prevent
the equipment from falling and damages, and more undesirably causing severe personal injuries.
Therefore, it is important to install the equipment as instructed by the manufacturer.
4. All peripheral devices must be grounded.
5. No external connection wires can be exposed. All connections and idle wire ends must be
wrapped with insulating tapes to prevent accidental contact with exposed wires from damaging
the equipment.
6. Do not attempt to carry out unauthorized repair of the equipment. Disassembly or detachment is
likely to cause electric shock or other physical problems. All repair should be done by qualified
repair personnel.
7. In any of the following cases, disconnect the power supply from the equipment first and notify
qualified repair personnel for repair:
 The power cord or connector is damaged;
 Liquid leaks into or any objects fall into the equipment;
 The equipment has got wet or exposed to bad weather (rain, snow, etc.);
 If the equipment cannot work normally even though it is operated as instructed;
 The equipment falls down or its performance changes obviously.
8. If it is necessary to replace a component, the repair personnel must use only the substitutes
specified by the manufacturer.
9. After the equipment is repaired, the repair personnel needs to conduct security inspection to
ensure the equipment works normally.
10. Operate the equipment with only the type of power supply indicated on the label. Contact the
operator for any uncertainty about the type of power supply.

Violation of any of the following cautions may result in personal injury or equipment malfunctions.
We assume no responsibility for any damage caused by mishandling that is beyond normal usage
defined in this product manual.

 Before installation, switch off the external circuit (that supplies power to the system).
 Before connecting the equipment to power supply, ensure the output voltage is within the specified
range.
 Never connect the product to the power before completion of installation.

P a g e |7 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Installation Cautions

1. To protect the wiring from rats, all wires should be placed in pipes. It is recommended to use PVC
conduits or galvanized tubes. Although the control panel has a good anti-static, anti-lightning,
and anti-leakage design, it is important to ensure that the case of the control panel and the AC
ground wire are connected perfectly and the AC ground wire is grounded.
2. It is recommended not to plug and unplug connection terminals frequently when the system is
energized. Be sure to unplug the connection terminals before starting any relevant welding job.
3. Do not detach or replace any control panel chip without permission because unprofessional
operation may cause damage to the control panel.
4. It is recommended not to connect any other auxiliary devices without permission. All non-routine
operations must be confirmed with our engineers in advance.
5. A control panel should not share one power socket with any other large-current devices.
6. It is preferable to install card readers and buttons at a height of 55 inches to 59 inches (1.4m to
1.5m) above the ground, subject to proper adjustment according to customers’ usual practice.
7. It is advised to install the product in a place convenient for future maintenance, like a weak
electric well.
8. The exposed part of any connection terminal is strongly recommended not be longer than 0.16
inches (4mm). Professional clamping tools may be used to avoid short-circuit or communication
failure resulting from accidental contact with excessive exposed wires.
9. To save access control event records, exterminal data periodically from control panels.
10. Prepared countermeasures against unexpected power failure, like selecting power supply with
UPS.
11. If the RS485 reader is connected externally and shares the power supply with the device (The
control panel does not supterminal RS485 readers with fingerprint verification function), the
connection between the EXT RS485 terminal and the reader is recommended not to be longer
than 328 ft (100m). Otherwise, it is recommended to use a separate power supply for the reader.
12. The length of the connection between computer and elevator controller: RS485 communication is
less than 3937 ft (1200m). In order to make the communication more stable, it is recommended
to control within 2624 ft (800m). It is recommended to use the power supply delivered with the
system as the control panel power supply.
13. It is recommended to use the power supply delivered with the system as the control panel power
supply.
14. In a place with strong magnetic interference, galvanized steel pipes or shielded cables are recommended,
and proper grounding is required.

P a g e |8 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

2 Overview

System Introduction

The elevator control system is a digital management system that controls access to elevators for
personnels. This elevator control system introduced by ZKTeco mainly consists of the EC16 master
elevator controller, DEX16 floor expansion board, QR600 series reader and D147 card issuer and other
auxiliary equipment. Each elevator controller can be connected to up to seven floor expansion boards,
which can control up to 128 floors. After entering the elevator, users must swipe the card, QR code or
password inside the elevator to pass the authentication before they are authorized to press the
designated floor button and finally reach the corresponding floor.

Package C Enclosure Introduction

EC16 elevator master controller is a bare board, which can be installed and fixed to Package C enclosure, and
the DEX16 expansion board supports stacking and fixing on the master control board.

Figure 1-1 Package C Enclosure Appearance

No. Description
1 Status Indicator (Includes PWR, COMM, RUN)
2 Keyhole
3 Wire Hole
4 Heat Dissipation Holes

P a g e |9 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

System Equipment Composition

The elevator controller system is composed of the following equipments:

Figure 1-2 System Equipment Appearance

P a g e | 10 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

No. Description No. Description


1 Floor Button Control Port 16 Power Input
2 Extend Port 17 Ethernet Interface (LAN1)
3 Wiegand 18 TCP/IP Reader Interface (LAN2)
4 RS-485 19 U disk interface
5 LED Indicator 20 Reset Button
6 Elevator Door Closing Button 21 Floor Button Control Port
7 Elevator Door Opening Button 22 DIP Switch
8 Alarm Output 23 RS-485 Input
9 Speaker 24 RS-485 Output
10 Voice 25 Touch Keypad & RFID Card Reading Area
11 LED Indicator Port 26 Flash
12 Tamper Switch 27 QR Code Collector
13 FIRE 28 USB Jack
14 Emergency Button 29 RFID Card Reading Area
15 Manual Button 30 LED Indicator

Technical Parameters

EC16 Elevator Controller


Controllable Floors 16 floors Record Capacity 150,000

Adopt Package C enclosure


User Capacity 30,000 Power Supply
matching adapter

Face Capacity 30,000 PC Communication TCP/IP

Card Capacity 30,000 Reader Communication Wiegand, RS-485

Fingerprint Number of connectable Up to 7 DEX16s can be


30,000
Capacity expansion boards connected at the same time
Number of expandable
Block list Capacity 500 Up to 128 floors
floors
DEX16 Expansion Board
Communication With
Controllable Floors 16 floors Wiegand, RS-485
EC16
12V DC, powered
Power Supply
by EC16

P a g e | 11 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

LED Indicators Description

LED indicators on the EC16

When the EC16 elevator controller is powered on, the LED indicators under normal circumstances will
show the following.

Figure 1-3 LED indicator diagram of the elevator controller

 POWER indicator (Red):


Solid Red LED indicates normal energization.
 RUN indicator (Green):
Slowly flashing Green LED indicates normal working status of the system.
 COMM indicator (Yellow):
Slowly flashing Yellow LED indicates data communication is in progress.

LED indicators on the Package C Enclosure

 PWR indicator (Red):


Solid Red LED indicates normal energization.
 COMM indicator (Yellow):
Slowly flashing Yellow LED indicates data communication is in progress.
 RUN indicator (Green):
Slowly flashing Green LED indicates normal working status of the system.

P a g e | 12 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

3 Terminal Instructions

Figure 3-1 Terminal diagram of the elevator controller and the expansion board

The terminals are described as follows:

No. Terminal Number Description


Floor Button
1 16 Used to connect elevator buttons for floor selection control.
Control Port

2 Extend Port 1 Expansion output for connecting DEX16 expansion board to expand floors.

Wiegand reader communication terminal. Used to connect Wiegand readers,


3 Wiegand 2
etc. And supports line interruption alarm message alerts.

4 RS-485 1 RS-485 reader communication terminal, used to connect RS-485 reader.

Equipment operating status indicators, respectively, are power light (POWER),


5 LED Indicator 1
operating status indicator (RUN) and communication indicator (COMM).

Elevator Door
6 1 Used to connect the door closing button on the elevator operation panel.
Closing Button

Elevator Door
7 1 Used to connect the door opening button on the elevator operation panel.
Opening Button

8 Alarm Output 1 Used to connect with the alarm.

9 Speaker 1 Used to extend the voice announcement function.

Used to connect the voice control magic box to realize voice contact-free
10 Voice 1
elevator ride.

P a g e | 13 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

No. Terminal Number Description


11 LED Indicator Port 1 Used to indicate the operating status of the system. Connect to the enclosure.

12 Tamper Switch 1 Used to connect to the tamper switch of the enclosure.

13 It is used to connect the fire switch, after starting the fire button, all the keys of
FIRE 1
the elevator cannot be lit normally.
In an emergency, when the emergency interface receives a short-circuit signal,
Emergency the elevator control will not control the elevator keys, and the equipment can
14 1
Button only be restored to the control state if it is powered off and restarted or set by
software.
When the manual interface receives a short-circuit signal, the elevator control
15 Manual Button 1 will not control the elevator keys, and the elevator will resume the control state
after release.

16 12V power supply terminal, used to connect the Package C enclosure matching
Power Input 1
adapter to power the elevator controller.

17 Ethernet Interface
1 Used for equipment networking and remote control.
(LAN1)

18 TCP/IP Reader
1 Used to connect TCP/IP multimodal intelligent collection terminal.
Interface (LAN2)

19 U Disk Interface 1 Mainly used for upgrading the elevator controller.

20 Long press 1 to 5 seconds for U disk upgrade, 5 to 10 seconds to restart the


Reset Button 1
controller, 10 seconds or more to restore factory settings.

21 Floor Button
16 Used for connecting elevator extension floor buttons for floor selection control.
Control Port

22 Set the RS-485 address of the expansion board according to the current connection
DIP Switch 1
order of the expansion board and follow the operation prompt next to it.

23 Used to connect the signal output terminal of the EC16 controller (i.e. Extend
RS-485 Input 1
Port) or the signal output terminal of the upper level DEX16.

24 RS-485 Output 1 Used for output when connecting to DEX16 expansion floor.

Recommended use of wires:

Maximum transmission distance


Interface Wire specifications
(theoretical value)

Power Supply 18AWG*2PIN 1.5m

Adopt 6-core communication shielded wire


(RVVP 6*0.5mm) (6PIN, 8PIN, 10PIN for
Wiegand 100m
different readers) to reduce interference in
the transmission process

Floor Control 24AWG*2PIN 50m

Input 24AWG*2PIN 100m

Share power with control panel: 100m.


Adopt 4-core communication cable (RVVP
RS-485 Use independent power supply (connect with
4*0.5mm)
RS-485 signal interface only): 1000m.

P a g e | 14 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

4 Wiring Description

Elevator Controller Networking Cabling

Figure 4-1 Diagram of elevator controller networking cabling

Note: Make sure the power is turned off before wiring. Wiring in the energized state may cause serious
damage to the equipment.

P a g e | 15 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Connection Power Supply

This device uses the adapter matched with the Package C enclosure to supply power to the elevator
controller, providing a 12V power supply which takes into account the power consumption of the
elevator controller itself, the power consumption of up to seven DEX16 expansion boards and the
output power consumption of the RS-485 reader. The wiring is shown in the following diagram.

Figure 4-2 Power wiring diagram

P a g e | 16 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Ethernet Connection to the Computer

Connect the elevator controller and the computer software via Ethernet cable. The wiring is shown in
the following diagram.

Figure 4-3 Ethernet wiring diagram


Note:
1. IP addresses can cross network segments, but they must belong to the same subnet, and the gateway
and IP address must be in the same network segment.
2. Dual Ethernet interfaces: the default IP address 192.168.1.201 for the primary NIC and 192.168.2.202 for the
expansion NIC.
3. The IP address of the primary NIC can be set by yourself, and the network segment of the expansion NIC
must be 192.168.2.(1 to 253).

P a g e | 17 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Elevator Control and Elevator Button Wiring

 Elevator Button Wiring Description

Figure 4-4 Elevator button wiring schematic


Instruction:
Connect Signal Cable 1 to the NO terminal on the corresponding floor of the elevator logic controller. After
Signal Cable 2 is disconnected, COM and NC terminals are connected to the COM and NC terminals of the
corresponding floor respectively.

 Wiring for swipe to select floor and direct floor selection

Figure 4-5 Swipe card to select the floor and direct selection of floor wiring diagram

P a g e | 18 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Instruction:
S1 and S2 switches are two relays (S1 relay is normally closed and S2 relay is normally open) of the elevator
control board respectively. S1 is disconnected after power on, and S1 is closed after swiping the layer
selection card, then the elevator button can be lit by pressing; S2 is closed after swiping the direct access
card, then the elevator button will be lit automatically.

MO, EMG, FIRE, TAMPER Interface Description

Figure 4-6 MO, EMG, FIRE, TAMPER interface wiring diagram


Instructions:
1. When the MO interface becomes a short circuit, the elevator controller will cancel the control function
of the floor button. At this time, the elevator buttons can be operated manually. The "manual" function
can be canceled by directly changing the MO interface from short circuit to broken circuit.

2. When the EMG interface becomes short circuit, the elevator controller will cancel the key control of
each floor. To cancel the "emergency" function, please log in ZKBio CVSecurity software, click
[Elevator] > [Elevator Device] > [Real-time Monitoring] > [Emergency interface recovery button].

P a g e | 19 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

3. When the FIRE interface becomes a short circuit, all the keys of the elevator cannot be lit normally. If
you want to cancel the "fire" function, please log in ZKBio CVSecurity software, click [Elevator] >
[Elevator Device] > [Device] and then check the equipment that needs to restart, select [Control] >
[Restart device] to complete the restart of the elevator control equipment, see the following figure for
detailed steps.

4. When the TAMPER interface becomes a broken circuit, the system will push the tampering alarm
information in real time and send an alarm sound.
5. Fire and emergency functions require no software setup, just a hardware connection for use.
6. In this elevator controller system, the fire interface has the highest level, followed by the emergency
interface, and finally the manual interface.
7. When an alarm is connected to the auxiliary output of the controller, the status of the alarm and the
event description of the software side after the interface is short circuit or broken circuit are as follows.

Interface Line Status Auxiliary Output (Alarm) Event description on the software
Real-time pushing of "manual button short circuit" information
Short circuit Uninterrupted alarm
and one alarm sound
MO Real-time pushing of "manual button short circuit" information
Broken circuit Stop alarm
and one alarm sound
Note: The alarm can be canceled by disconnecting the "manual" interface of the elevator control equipment.
Real-time pushing of "emergency button short circuit"
Short circuit Uninterrupted alarm
information and one alarm sound

EMG Real-time pushing of "emergency button short circuit"


Broken circuit Uninterrupted alarm
information and one alarm sound
Note: The alarm can be cancelled by clicking the [Emergency Interface Recovery] button or by restarting the
device on the software side.

P a g e | 20 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Real-time pushing of "fire button short circuit" information and


Short circuit Uninterrupted alarm
one alarm sound
FIRE Real-time pushing of "fire button break" information and one
Broken circuit Uninterrupted alarm
alarm sound
Note: The alarm can be cancelled by restarting the device on the software side.
Short circuit No alarm No information push and no alarm sound.
TAMPER Real-time pushing of "tamper alarm" information and one
Broken circuit No alarm
alarm sound

Wiring of Expansion Board

Figure 4-7 MO, EMG, FIRE, TAMPER interface wiring diagram


Note:
1. Use the software setup after connecting the DEX16 module to the EC16 master controller.
2. A maximum of seven DEX16 extended boards can be connected to one EC16 controller.The total can be
expanded to 128 layers at most.
3. Before power is supplied, use the DIP switch to set the RS-485 addresses of the DEX16s, following the
order in which each DEX16 is connected.
4. The DIP switch needs to be set with the control board powered off and takes effect after restart. After
setting, the DIP switch does not need to be set back to its original position.

P a g e | 21 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Installation of Elevator Management System

The elevator management system consists of two parts, which are the management workstation (PC)
and the elevator controller. The management workstation and elevator controller adopt TCP/IP
communication mode. The communication line is as far away from the high-voltage electric line as
possible, and should not be wired in parallel with the power line, let alone bundled together.
The management workstation is a PC connected to the network, and the elevator manager can realize
various remote management functions, including adding/removing users, viewing various event
records, entering/exiting elevators and monitoring the status of each elevator in real time, etc. just by
running the elevator control management software on it.
The following diagram shows the installation of EC16 elevator controller system.

Figure 4-8 Diagram of elevator management system

P a g e | 22 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Elevator Controller System Power Supply Structure

Figure 4-9 Diagram of elevator controller system power supply structure

The EC16 elevator controller is powered by +12V DC power supply.


When using +12V DC power supply, generally speaking, in order to reduce the influence of power
interference between elevator controllers, each elevator controller should be powered separately. In
order to prevent the loss of power to the elevator controller and cause the whole system to fail to work
normally, the elevator management system is generally required to be equipped with at least one UPS
uninterruptible power supply.

P a g e | 23 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5 Elevator control operating instructions

Connect to ZKBio CVSecurity Software

The elevator controller needs to be connected to the software and set the corresponding parameters
to use the elevator control function in the software system, and can manage the equipment through
the system, upload the user's elevator control data, download the configuration information and
output various reterminals to realize the digital management of the enterprise.

5.1.1 Login Software

1. Open your browser, enter the server IP address and terminal number (e.g. https://127.0.0.1:8098/)
in the address bar, click Enter to enter the login page.
2. Or double-click the desktop the ZKBio CVSecurity icon to bring up the system login page.
3. For the first time to use this system, default user name admin and password admin, click [Login],
or click [Fingerprint Login] on the interface, then press the administrator finger on the
fingerprint device to enter the system home page.
4. To use this system for the first time, enter the default user name admin and password admin and
click [Login]. Or click the icon of Other login mode on the interface, then press admin finger
on the fingerprint device to enter the system home page.
Note:
1. To ensure the safety of using the system, you must change the default password after logging into the
system.
2. For more details, please refer to the ZKBio CVSecurity User Manual.

P a g e | 24 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.2 Add Device on the Software

Add elevator control device by searching, the operation process is as follows.


1. Click [Elevator] > [ElevatorDevice] > [Device] > [Search], to open the Search interface in the
software.
2. Click [Search] on the pop-up search page.
3. After the search is completed, the list and total number of elevator controllers will be displayed.

4. Click the [Add] button after the device and make sure to finish adding it.

5. Set the relevant parameters.


6. Click [OK] to complete the operation of adding elevator control device.
7. Click [Close] to close the Device Search Add interface.

P a g e | 25 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Note:
When the device cannot be added to the software, please check the following information.
1. When the device can not be added, please check whether the communication is HTTP or HTTPS.
2. Whether PC and Elevator control device can PING through.
3. Whether the corresponding server IP of the device is correct.

5.1.3 Synchronize All Data to Devices


Register user and send to elevator control device. The operation steps are as follows.
1. Click [Personnel] > [Personnel] > [Person] > [New] to register users in the software.
2. Add users to elevator control level.
3. Click [Elevator] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all
data to the controller, including new users.

P a g e | 26 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.4 Add Expansion Board on the Software

1. Click [Elevator] > [Elevator Device] > [Expanding Board] to enter the setting interface.
2. Click[New] to add a expanding board.
3. Click [Device Name] and select the expansion board in the pop-up window.

4. Select the expansion board and then click to move it to the selected column on the right.
5. Click [OK] to confirm and exit.
6. After setting all parameters, click [OK] on the New page, when the pop-up "The operation
succeeded!" prompt means add extension board is completed.

Note: The RS485 address is input according to the dip switch setting of the expansion board, check the dip
switch setting in 4.6 Wiring of Expansion Board for details.

P a g e | 27 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.5 Add Reader on the Software

EC16 elevator controller supterminals connecting Wiegand or RS-485 communication reader.

5.1.5.1 Connect RS-485 Reader via RS-485


1. Connect the VCC, GND, 485A and 485B terminals of the reader to the RS-485 communication
terminal of the elevator controller, and the wiring is shown in the following figure.

Figure 5- 1 Wiring Schematic of RS-485 Reader and EC16 Elevator Controller

2. Set the 485 addresses (machine number) of the reader by software.


1) Click [Elevator] > [Elevator Device] > [Reader] to enter the setting interface.

2) Select the reader and click [Edit] icon behind it to enter the editing screen.
3) Change the communication type of the reader to RS485 in the edit window and enter the RS485
address.
4) Click [OK] to confirm and exit, as shown in the figure below.

P a g e | 28 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

3. Each EC16 can connect a maximum of eight RS-485 readers, as shown in the figure below.

Figure 5- 2 Wiring diagram of elevator controller and multiple RS-485 readers

Remarks:
When connecting the RS-485 readers through the RS-485 communication terminal of the elevator
controller, it can provide a maximum current output of 3A (12V), so when using the power output of
the RS-485 communication terminal to supply power to multiple readers, the overall working current
of the reader cannot exceed this value and should be left with sufficient margin. In the calculation, the

P a g e | 29 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

maximum current for each reader is calculated (Note: the instantaneous current of the device at the
time of start-up is the largest, which can be more than twice the normal work, and this situation must
be considered when calculating). In addition, if the reader shares power with the device, it is
recommended that the RS-485 communication terminal and the RS-485 reader should not be
connected to more than 3937 ft (100m), otherwise it is recommended that a separate power supply be
used.
Note: For devices with high power consumption, it is recommended to use separate power supply to ensure
stable operation of the device.

5.1.5.2 Connect Wiegand Reader via Wiegand


EC16 elevator controller can connect two Wiegand readers.
The elevator controller provides Wiegand interface for the readers, which can be connected to
different types of readers. If your reader uses a voltage other than DC 12V, an external power supply
device is required. The reader should be installed about 55 inches (1.4m) from the ground and 0.1
inches to 0.2 inches (30 to 50mm) from the door edge frame.

Figure 5- 3 Wiring Diagram of EC16 Elevator Controller and Wiegand Reader

5.1.6 Set Elevator Control Rules on Software


Note that when setting elevator control rules, when the "Direct Selection Set" function is set, other
floor permissions such as those set in "Elevator Levels", "Set Access By Levels", "Set Access By Person",
"Set Access By Department" will be invalid, when the "Direct Selection Set" function is canceled, the
floor permissions set will be valid again.

Note:
Elevator Levels, Set Access By Levels, Set Access By Person and Set Access By Department function are mainly
used as visitor authority.

P a g e | 30 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.6.1 Set Elevator Control Levels Group


1. Click [Elevator] > [Elevator Control Rule] > [Elevator Levels] to enter the setting interface.
2. Click [New] to add a new elevator control level group.
3. Enter the level name, time zones and setting area, then click [OK] to confirm and exit.

4. After adding successfully, check the levels group.

5. Click [Add Floor] icon in the levels group bar to open the settings window.

6. Select the floor and then click to move it to the selected column on the right.
7. Click [OK] to confirm and exit.

P a g e | 31 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.6.2 Set Access by Levels


Add personnel to the elevator control level group.
1. Click [Elevator] > [Elevator Control Rule] > [Set Access By Levels] to enter the setting interface.
2. Check the levels group and click the [Add Personnel] icon in its bar to open the settings window.
3. Select the person and then click to move it to the selected column on the right.
4. Click [OK] to confirm and exit.

5.1.6.3 Set Access By Person


Edit the elevator control level group for personnel.
1. Click [Elevator] > [Elevator Control Rule] > [Set Access By Person] to enter the setting interface.

2. Check the levels group and click the [Add to Levels] icon in its bar to open the settings window.
3. Select the levels group and then click to move it to the selected column on the right.
4. Click [OK] to confirm and exit.

P a g e | 32 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.1.6.4 Set Access By Department


Edit the elevator control level group for the department.
1. Click [Elevator] > [Elevator Control Rule] > [Set Access By Department] to enter the setting
interface.

2. Check the department and click the [Add to Default Levels] icon in its bar to open the
settings window.

3. Select the levels group and then click to move it to the selected column on the right.
4. Click [OK] to confirm and exit.

5.1.6.5 Direct Selection Floor Setting

You can set a direct selection floor for users or visitors here; or set other floors that can be selected in
addition to the direct selection floor.

 Direct Selection Floor

1. Click [Elevator] > [Elevator Control Rule] > [Direct Selection Set] to set the floor that can be
reached directly for personnel.
2. Click the query icon to search the list of editable personnel.

3. Check the people you need to set in the list, and click icon to add direct access to the floor for
the people.

P a g e | 33 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

4. In the Add direct selection layer pop-up window, click on the drop-down menu to select the
elevator device, direct floor and time zones.

5. Click [OK] to save and exit.

 Select Floor

1. In the pop-up window of Add direct selection layer, click [Click to select] in the select floor
column to select the floor.
2. Once the setup is complete, the user is allowed to access the authorized floor. Once the user is
authenticated at the reader, he/she can press his/her authorized floor button directly on the floor
panel to light up that floor.

Note: Unauthorized floor buttons will not respond when pressed.

P a g e | 34 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

User Verification on the QR-600 Series Readers

When the QR-600 Series Reader successfully communicates with the elevator controller (see 5.1.5 Add
Reader on the Software for details on the connection method), the user can verify on the QR-600 series
reader.
Users can authenticate with passwords, cards and QR codes on the QR-600 series reader. When the
verification is successful, the user can reach the authorized floor.
When a user or visitor is authorized to go straight to the floor, the authorized floor is directly lit when
he verifies successfully.
When a user or visitor is authorized to reach multiple floors, when he verifies successfully, he needs to
manually light up the authorized floor to reach it.
Note: Unauthorized floors will not respond when the user presses the floor button.

Connect to ZKBioSecurity Mobile App

Employees can install ZKBioSecurity Mobile App on the mobile phone, and can use the QR code of the
electronic work card on the app to verify on QR-600 series reader to automatically light up the direct
floor or manually light up the optional floor. The specific operation steps are as follows.

5.3.1 Mobile App Configuration


After downloading and installing the App, the user needs to set the Server before login. The steps are
given below:
1. On the Server, choose [System] > [Authority Management] > [Client Register] to enter the
Client Register interface.
2. Click [New] to add a registered App client.
3. Select the Registration Code. If the app is used by an administrator, register "APP Client-Administrator",
and the mobile phone using the registration code can login to the administrator account and
employee account. If the app is used by an employee, register "APP Client-Staff" and the mobile
phone with the registration code can only login to the employee account.
4. Click [OK] to save and exit.

P a g e | 35 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5. Open the App on the Smartphone. On the login screen, tap [Server Setting] and type the IP
Address or the Domain Name of the Server, and its Port Number.
6. Tap the QR Code icon to scan the QR code of the new App client. After the client is identified
successfully, set the Client Name and tap [Testing Connection].
7. After the network is connected successfully, tap [Save].

P a g e | 36 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Note: The APP's network connection and the server's network connection need to be in the same LAN,
otherwise the network will be unavailable.

5.3.2 Login
Initially, it is required to configure the Server Settings before login. After the Server settings are
successfully saved, it will automatically return to the login screen.
1. Select the login identity which includes Administrator login and Employee login.
2. The default is "Admin". When the Employee needs to login, tap on Employee to switch to
Employee login screen.

3. The administrator can login with the username in [System] > [Authority Management] > [User]
and self-service password. The default self-service password is 111111.

P a g e | 37 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

4. Employees can login with the Personnel ID in [Personnel] > [Personnel] > [Person] and self-
service password. The default self-service password is 123456.

5. The employee login diagram is shown in the figure:

P a g e | 38 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

6. The Administrator and Employee can change the Password in the App System Settings.

Notes: The license determines the number of available Mobile App connections. Users can view it by clicking
[Personal Information] > [About Path], as shown below.

7. Each registration code consumes a licensed App point and can only be assigned to one mobile
phone.

5.3.3 Enable the Dynamic QR Code on the Software


Open ZKBio CVSecurity software, click [System] > [System Management] > [Parameters] to enable
the dynamic QR code. Set the relevant parameters in the page, click OK to save and exit. As shown in
the figure below.

P a g e | 39 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

5.3.4 Verification QR Code


After logging into the ZKBioSecurity Mobile App as an employee, click on the mobile credential icon
and bring up the QR code to verify on the reader. After successful verification, you can go straight to
the authorized floor or you can light up the authorized floor manually.

1. Select Employee and enter the account information, then click Login to enter the App.

2. Click the Mobile Credential icon to enter the QR Code interface.

3. Place this QR code in front of the QR code collector of the reader for verification.

P a g e | 40 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

6 Communication Connection
The backend PC software is able to communicate with the system via TCP/IP for data exchange and
remote management. Communication lines are as far away from high-voltage power lines as possible,
and should not be wired in parallel with power lines, let alone bundled together.

Access Control Networking Wires and Wiring

1. The power supply is 12V DC converted from 220V or POE.


2. The Wiegand readers use 6-core communication shielded wires (RVVSP 6×0.5mm) (usually there are
different types of wires available, namely, 6-core, 8-core, and 10-core for users to select according to
the ports) to reduce interference during transmission.
3. As an electronic lock produces a big current, it generates strong interference signals during an action.
To reduce the effect of an electronic lock during an action on other elements, 4-core wires (RVVP
4×0.75mm2, two for a power supply and two for a door sensor) are recommended.
4. “EXT RS485” interface use 4-core communication shielded wires (RVVSP 4*0.5mm).
5. Other control cables like exit switches are all made of 2-core wires (RVVSP 2×0.5mm2).
6. Notes for wiring:
 Signal wires (like network cables) can neither run in parallel with nor share one casing pipe with
large-power electric wires (like electronic lock wires and power cables). If parallel wiring is
unavoidable for environmental reasons, the distance must be over 50cm.
 Try to avoid using any conductor with a connector during distribution. When a connector is
indispensable, it must be crimped or welded. No mechanical force can be applied to the joint or
branch of conductors.
 In a building, distribution lines must be installed horizontally or vertically. They should be protected
in casing pipes (like plastic or iron water pipes, to be selected according to the technical
requirements of indoor distribution). Metal hoses are applicable to ceiling wiring, but must be
secure and good-looking.
 Shielding measures and shielding connection: If the electromagnetic interference in the wring
environment is found strong in the survey before construction, it is necessary to consider shielding
protection for data cables when designing a construction scheme. Overall shielding protection is
required if there is a large radioactive interference source or wiring has to be parallel with a large-
current power supply on the construction site. Generally, shielding measures include: keeping a
maximum distance from any interference source, and using metal wiring troughs or galvanized
metal water pipes to ensure reliable grounding of the connection between the shielding layers of
data cables and the metal troughs or pipes. Note that a shielding enclosure can have a shielding
effect only when it is grounded reliably.
 Ground wire connection method: Reliable large-diameter ground wires in compliance with
applicable national standards are needed on the wiring site and should be connected in a tree form
to avoid DC loop. These ground wires must be kept far away from lightning fields. To ensure that
there is no lightning current through any ground wire when there is lightning, no lightning
conductors can be used. Metal wiring troughs and pipes must be connected continuously and
reliably and linked to ground wires through large-diameter wires. The impedance of this section of
wire cannot exceed 2ohm. The shielding layer also must be connected reliably and grounded at one
end to guarantee uniform current direction. The ground wire of the shielding layer must be
connected through a wire with large-diameter (not smaller than 2.5mm2).

P a g e | 41 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

TCP/IP Communication

The Ethernet 10/100Base-T Crossover Cable, a type of crossover network cable, is mainly used for
cascade hubs and switches, or used to connect two Ethernet end-points directly without a hub. Both
10Base-T and 100Base-T are supterminaled.

Figure 6-1 Diagram of TCP/IP communication

1. In ZKBio CVSecurity software, click [Elevator] > [Elevator Device] >[Device] to enter the setting
interface.
2. Click [Search] to open the Search interface in the software.
3. After the search is completed, a list of controllers will be displayed. Select the controller in the list
and click [Add] behind the action bar.
4. In the Add window, enter the relevant parameters for the controller.
5. Click [OK] to save and exit.

P a g e | 42 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

6. The factory default IP address of the device is: 192.168.1.201, after the device is added successfully,
you can modify the IP address of the device in the communication column. Select the device, click
[Elevator] > [Elevator Device] > [Set up] > [Modify IP Address], modify the IP address of NIC 1
and click [OK].

Modify the IP address

The default IP address of the primary NIC when the elevator controller is shipped is 192.168.1.201. It
may conflict with the IP of other devices in the network, so the new device needs to modify the IP
address before use. It can be modified by the following ways.

 Modify by Search Tool

1. After logging in the ZKBio CVSecurity software, click [Elevator] > [ElevatorDevice] > [Device] >
[Search], click [Download Search Tools to Local Disk] in the search device window, download
the search tool deviceSettingTool_overseas.exe to your computer.
Note: At the bottom of the search device interface will prompt the current system communication
terminal number.

2. Double-click to open the search screen, and click the icon to


search for the device, then the IP address of the controller is displayed.

P a g e | 43 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

3. Select the device to be modified, click the icon to modify the IP address of the device, click
[OK] after setting the parameters, as the following figure shows.

 Old IP Address: The IP address of the device. The factory default IP address of the device is:
192.168.1.201.
 New IP Address: The new IP address of the device. Note: The IP address of the device and the IP
address of the computer must be in the same network segment.
 Subnet Mask: Default subnet mask 255.255.255.0, can be modified as needed.
 Gateway: Default gateway address 0.0.0.0, can be modified as needed. Note: The gateway and
the IP address must be in the same network segment.
 Access Server IP: The IP address of the ZKBio CVSecurity software server.
 Access Server Port: Enter the communication terminal number of the current system, which is
indicated under the "Search" pop-up window.

 Modify the IP Address in the software

After adding devices successfully in the software (see 5.1.2 Add Device on the Software), you can
change the IP address in the device list field.
1. Click [Elevator] > [Elevator Device] > [Device] to enter the setting interface.
2. Check the added device in the device list.
3. Click [Set up] > [Modify IP address] to bring up the settings window.

P a g e | 44 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

4. Modify the IP address of Network card 1 in the pop-up window.


5. Click [OK] to save and exit.

Note: Network card 1 is the IP address of the primary NIC of the elevator controller, and Network card 2 is the
IP address of the extended NIC of the elevator controller.

P a g e | 45 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

7 Others

USB Disk Upgrade

USB interface can be used to upgrade the elevator controller, the usage is as follows.
1. First, create a new “Udisk” folder in the USB disk, and put the upgrade file into “Udisk”.
2. Under the normal operation of the elevator controller, insert the U disk, press the [Reset] key for 1
to 5 seconds (the operation light will flash) and release it.
3. The operation light will keep flashing during the upgrade process (no power failure during the
upgrade, no unplugging of the U disk), and the elevator controller will restart automatically after
the upgrade is successful.
4. If the upgrade is unsuccessful, the elevator controller will return to normal operation.

Restore Factory Settings

The EC16 elevator controller can be restored to factory settings by [RESET] key. Press the [RESET]
button, 1 to 5 seconds to upgrade with USB disk, 5 to 10 seconds to restart the controller, 10 seconds
or more to restore the factory settings.
Note: When restoring the factory settings, only the network configuration of the device is restored,
and other data is not restored.

P a g e | 46 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Appendix 1 Buzzer, Indicator Light Prompt Instructions


EC16 elevator controller works normally online, when the user verifies the RFID card in RS-485 reader
and Wiegand reader, the buzzer and indicator prompts are shown in the following table.

Working Status Buzzer Indicator Light

Verification Success 1 short sound LED indicator lights green.

Verification Failure LED indicator (red) lights up


2 short sound
(swipe unregistered card) briefly twice.

2 short sound 1 long LED indicator (red) lights up


Validation method error
sound twice short and then once long.

Data transfer error 1 short sound 1 long LED indicator (red) lights up
(Wiegand format error) sound one short and then once long.

No permission (person has expired, the


operation interval is too short, door is
LED indicator (red) lights up
not valid time period verification open, 3 short sound
briefly three times.
illegal time period, illegal access, wrong
verification method, block list)

Continue validation during combination Flashing green light three


/
validation times.

4 short sound (timeout LED indicator (red) lights up


Combined verification is not completed
time of 10s) briefly four times.

4 short sound (timeout LED indicator (red) lights up


Timeout
time of 8s) briefly four times.

P a g e | 47 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Appendix 2 Privacy Policy


Notice:
To help you better use the products and services of ZKTeco and its affiliates, hereinafter referred as
“we”, “our”, or “us”, the smart service provider, we consistently collect your personal information. Since
we understand the importance of your personal information, we took your privacy sincerely and we
have formulated this privacy policy to protect your personal information. We have listed the privacy
policies below to precisely understand the data and privacy protection measures related to our smart
products and services.
Before using our products and services, please read carefully and understand all the rules and
provisions of this Privacy Policy. If you do not agree to the relevant agreement or any of its
terms, you must stop using our products and services.

I. Collected Information

To ensure the normal product operation and help the service improvement, we will collect the
information voluntarily provided by you or provided as authorized by you during registration and
use or generated as a result of your use of services.

1. User Registration Information: At your first registration, the feature template (Fingerprint
template/Face template/Palm template) will be saved on the device according to the
device type you have selected to verify the unique similarity between you and the User ID you
have registered. You can optionally enter your Name and Code. The above information is
necessary for you to use our products. If you do not provide such information, you cannot use
some features of the product regularly.

2. Product information: According to the product model and your granted permission when
you install and use our services, the related information of the product on which our services
are used will be collected when the product is connected to the software, including the
Product Model, Firmware Version Number, Product Serial Number, and Product Capacity
Information. When you connect your product to the software, please carefully read the
privacy policy for the specific software.

II. Product Security and Management

1. When you use our products for the first time, you shall set the Administrator privilege before
performing specific operations. Otherwise, you will be frequently reminded to set the
Administrator privilege when you enter the main menu interface. If you still do not set the
Administrator privilege after receiving the system prompt, you should be aware of the
possible security risk (for example, the data may be manually modified).

2. All the functions of displaying the biometric information are disabled in our products by
default. You can choose Menu > System Settings to set whether to display the biometric
information. If you enable these functions, we assume that you are aware of the personal
privacy security risks specified in the privacy policy.

P a g e | 48 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

3. Only your user ID is displayed by default. You can set whether to display other user
verification information (such as Name, Department, Photo, etc.) under the Administrator
privilege. If you choose to display such information, we assume that you are aware of the
potential security risks (for example, your photo will be displayed on the device
interface).

4. The camera function is disabled in our products by default. If you want to enable this function
to take pictures of yourself for attendance recording or take pictures of strangers for access
control, the product will enable the prompt tone of the camera. Once you enable this
function, we assume that you are aware of the potential security risks.

5. All the data collected by our products is encrypted using the AES 256 algorithm. All the data
uploaded by the Administrator to our products are automatically encrypted using the AES
256 algorithm and stored securely. If the Administrator downloads data from our products,
we assume that you need to process the data and you have known the potential security risk.
In such a case, you shall take the responsibility for storing the data. You shall know that some
data cannot be downloaded for sake of data security.

6. All the personal information in our products can be queried, modified, or deleted. If you no
longer use our products, please clear your personal data.

III. How we handle personal information of minors

Our products, website and services are mainly designed for adults. Without consent of parents or
guardians, minors shall not create their own account. If you are a minor, it is recommended that
you ask your parents or guardian to read this Policy carefully, and only use our services or
information provided by us with consent of your parents or guardian.

We will only use or disclose personal information of minors collected with their parents' or
guardians' consent if and to the extent that such use or disclosure is permitted by law or we have
obtained their parents' or guardians' explicit consent, and such use or disclosure is for the purpose
of protecting minors.

Upon noticing that we have collected personal information of minors without the prior consent
from verifiable parents, we will delete such information as soon as possible.

IV. Others

You can visit https://www.zkteco.com/cn/index/Index/privacy_protection.html to learn more about how


we collect, use, and securely store your personal information. To keep pace with the rapid
development of technology, adjustment of business operations, and to cope with customer needs,
we will constantly deliberate and optimize our privacy protection measures and policies.
Welcome to visit our official website at any time to learn our latest privacy policy.

P a g e | 49 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


EC16 Elevator Control Panel & DEX16 Elevator Floor Extension Board User Manual

Appendix 3 Eco-friendly Operation

The product's "eco-friendly operational period" refers to the time during which this product
will not discharge any toxic or hazardous substances when used in accordance with the
prerequisites in this manual.
The eco-friendly operational period specified for this product does not include batteries or
other components that are easily worn down and must be periodically replaced. The
battery's eco-friendly operational period is 5 years.

Hazardous or Toxic substances and their quantities

Hazardous/Toxic Substance/Element

Component Hexavalent Polybrominated


Name Mercury Cadmium Polybrominated
Lead (Pb) Chromium Diphenyl Ethers
(Hg) (Cd) Biphenyls (PBB)
(Cr6+) (PBDE)

Chip Resistor × ○ ○ ○ ○ ○
Chip Capacitor × ○ ○ ○ ○ ○
Chip Inductor × ○ ○ ○ ○ ○
Diode × ○ ○ ○ ○ ○
ESD
component
× ○ ○ ○ ○ ○
Buzzer × ○ ○ ○ ○ ○
Adapter × ○ ○ ○ ○ ○
Screws ○ ○ ○ × ○ ○
○ indicates that the total amount of toxic content in all the homogeneous materials is below the limit
as specified in SJ/T 11363—2006.
× indicates that the total amount of toxic content in all the homogeneous materials exceeds the limit
as specified in SJ/T 11363—2006.
Note: 80% of this product’s components are manufactured using non-toxic and eco-friendly
materials. The components which contain toxins or harmful elements are included due to the current
economic or technical limitations which prevent their replacement with non-toxic materials or
elements.

P a g e | 50 Copyright©2023 ZKTECO CO., LTD. All rights reserved.


]ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town, Dongguan, China.

Phone : +86 769 - 82109991

Fax : +86 755 - 89602394

www.zkteco.com

ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town,
ZKTeco Dongguan,
Industrial China.
Park, No. 32, Industrial Road,
Phone : +86
Tangxia 769 -Dongguan,
Town, 82109991 China.

FaxPhone : +86
: +86 755769 - 82109991
- 89602394
Fax : +86 755 - 89602394
www.zkteco.com
www.zkteco.com