EC 16 & DEX16 User Manual
EC 16 & DEX16 User Manual
EC 16 & DEX16 User Manual
English
Thank you for choosing our product. Please read the instructions carefully
before operation. Follow these instructions to ensure that the product is
functioning properly. The images shown in this manual are for illustrative
purposes only.
Trademark
is a registered trademark of ZKTeco. Other trademarks involved in this manual are owned
by their respective owners.
Disclaimer
This manual contains information on the operation and maintenance of the ZKTeco equipment. The
copyright in all the documents, drawings, etc. in relation to the ZKTeco supplied equipment vests in
and is the property of ZKTeco. The contents hereof should not be used or shared by the receiver with
any third party without the express written permission of ZKTeco.
The contents of this manual must be read as a whole before starting the operation and maintenance of
the supplied equipment. If any of the content(s) of the manual seems unclear or incomplete, please
contact ZKTeco before starting the operation and maintenance of the said equipment.
It is an essential pre-requisite for the satisfactory operation and maintenance that the operating and
maintenance personnel are fully familiar with the design and that the said personnel have received
thorough training in operating and maintaining the machine/unit/equipment. It is further essential for
the safe operation of the machine/unit/equipment that personnel has read, understood and followed
the safety instructions contained in the manual.
In case of any conflict between terms and conditions of this manual and the contract specifications,
drawings, instruction sheets or any other contract-related documents, the contract conditions/
documents shall prevail. The contract specific conditions/documents shall apply in priority.
ZKTeco does not assume responsibility for any errors or omissions in the information or documents
which are referenced by or linked to this manual. The entire risk as to the results and performance
obtained from using the information is assumed by the user.
ZKTeco in no event shall be liable to the user or any third party for any incidental, consequential,
indirect, special, or exemplary damages, including, without limitation, loss of business, loss of profits,
business interruption, loss of business information or any pecuniary loss, arising out of, in connection
with, or relating to the use of the information contained in or referenced by this manual, even if
ZKTeco has been advised of the possibility of such damages.
This manual and the information contained therein may include technical, other inaccuracies or
typographical errors. ZKTeco periodically changes the information herein which will be incorporated
into new additions/amendments to the manual. ZKTeco reserves the right to add, delete, amend or
modify the information contained in the manual from time to time in the form of circulars, letters,
notes, etc. for better operation and safety of the machine/unit/equipment. The said additions or
amendments are meant for improvement /better operations of the machine/unit/equipment and such
amendments shall not give any right to claim any compensation or damages under any circumstances.
ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions due to any
non-compliance of the instructions contained in this manual (ii) in case of operation of the
machine/unit/equipment beyond the rate limits (iii) in case of operation of the machine and
equipment in conditions different from the prescribed conditions of the manual.
The product will be updated from time to time without prior notice. The latest operation procedures
and relevant documents are available on http://www.zkteco.com.
ZKTeco Headquarters
Address ZKTeco Industrial Park, No. 32, Industrial Road,
The founders of ZKTeco have been determined for independent research and development of
biometric verification procedures and the productization of biometric verification SDK, which was
initially widely applied in PC security and identity authentication fields. With the continuous
enhancement of the development and plenty of market applications, the team has gradually
constructed an identity authentication ecosystem and smart security ecosystem, which are based on
biometric verification techniques. With years of experience in the industrialization of biometric
verifications, ZKTeco was officially established in 2007 and now has been one of the globally leading
enterprises in the biometric verification industry owning various patents and being selected as the
National High-tech Enterprise for 6 consecutive years. Its products are protected by intellectual
property rights.
All figures displayed are for illustration purposes only. Figures in this manual may not be exactly
consistent with the actual products.
Document Conventions
Conventions used in this manual are listed below:
GUI Conventions
For Software
Convention Description
Bold font Used to identify software interface names e.g., OK, Confirm, Cancel.
Multi-level menus are separated by these brackets. For example, File >
>
Create > Folder.
For Device
Convention Description
<> Button or key names for devices. For example, press <OK>.
Window names, menu items, data table, and field names are inside square
[]
brackets. For example, pop up the [New User] window.
Symbols
Convention Description
Table of Contents
1 SAFETY INSTRUCTIONS ....................................................................................................................... 7
IMPORTANT SECURITY INSTRUCTIONS ...............................................................................................................................7
INSTALLATION CAUTIONS ...................................................................................................................................................8
2 OVERVIEW ............................................................................................................................................ 9
SYSTEM INTRODUCTION ..................................................................................................................................................... 9
PACKAGE C ENCLOSURE INTRODUCTION ......................................................................................................................... 9
SYSTEM EQUIPMENT COMPOSITION ............................................................................................................................... 10
TECHNICAL PARAMETERS .................................................................................................................................................11
LED INDICATORS DESCRIPTION ......................................................................................................................................12
3 TERMINAL INSTRUCTIONS ................................................................................................................ 13
4 WIRING DESCRIPTION ........................................................................................................................15
ELEVATOR CONTROLLER NETWORKING CABLING ..........................................................................................................15
CONNECTION POWER SUPPLY ........................................................................................................................................ 16
ETHERNET CONNECTION TO THE COMPUTER ................................................................................................................ 17
ELEVATOR CONTROL AND ELEVATOR BUTTON WIRING ............................................................................................... 18
MO, EMG, FIRE, TAMPER INTERFACE DESCRIPTION ................................................................................................19
WIRING OF EXPANSION BOARD ...................................................................................................................................... 21
INSTALLATION OF ELEVATOR MANAGEMENT SYSTEM ..................................................................................................22
ELEVATOR CONTROLLER SYSTEM POWER SUPPLY STRUCTURE ................................................................................... 23
5 ELEVATOR CONTROL OPERATING INSTRUCTIONS ......................................................................... 24
CONNECT TO ZKBIO CVSECURITY SOFTWARE ..............................................................................................................24
5.1.1 LOGIN SOFTWARE ................................................................................................................................................ 24
5.1.2 ADD DEVICE ON THE SOFTWARE ........................................................................................................................25
5.1.3 SYNCHRONIZE ALL DATA TO DEVICES ...............................................................................................................26
5.1.4 ADD EXPANSION BOARD ON THE SOFTWARE ...................................................................................................27
5.1.5 ADD READER ON THE SOFTWARE .......................................................................................................................28
5.1.6 SET ELEVATOR CONTROL RULES ON SOFTWARE .............................................................................................. 30
USER VERIFICATION ON THE QR-600 SERIES READERS ............................................................................................... 35
CONNECT TO ZKBIOSECURITY MOBILE APP ................................................................................................................. 35
5.3.1 MOBILE APP CONFIGURATION ............................................................................................................................35
5.3.2 LOGIN ....................................................................................................................................................................37
5.3.3 ENABLE THE DYNAMIC QR CODE ON THE SOFTWARE .....................................................................................39
1 Safety Instructions
1. Before operating the equipment, please read and strictly follow all security and operation instructions.
Please keep the instructions in good condition for future reference.
2. Please use the accessories recommended by the manufacturer or delivered together with the
product. Any other related product is not recommended to be used as the alarm or monitoring
system (cameras, infrared detectors, smoke detectors, etc.). The alarm or monitoring system
should comply with the local applicable fire-prevention and security standards.
3. Do not place this equipment on any unstable table, tripod mount, supterminal or base to prevent
the equipment from falling and damages, and more undesirably causing severe personal injuries.
Therefore, it is important to install the equipment as instructed by the manufacturer.
4. All peripheral devices must be grounded.
5. No external connection wires can be exposed. All connections and idle wire ends must be
wrapped with insulating tapes to prevent accidental contact with exposed wires from damaging
the equipment.
6. Do not attempt to carry out unauthorized repair of the equipment. Disassembly or detachment is
likely to cause electric shock or other physical problems. All repair should be done by qualified
repair personnel.
7. In any of the following cases, disconnect the power supply from the equipment first and notify
qualified repair personnel for repair:
The power cord or connector is damaged;
Liquid leaks into or any objects fall into the equipment;
The equipment has got wet or exposed to bad weather (rain, snow, etc.);
If the equipment cannot work normally even though it is operated as instructed;
The equipment falls down or its performance changes obviously.
8. If it is necessary to replace a component, the repair personnel must use only the substitutes
specified by the manufacturer.
9. After the equipment is repaired, the repair personnel needs to conduct security inspection to
ensure the equipment works normally.
10. Operate the equipment with only the type of power supply indicated on the label. Contact the
operator for any uncertainty about the type of power supply.
Violation of any of the following cautions may result in personal injury or equipment malfunctions.
We assume no responsibility for any damage caused by mishandling that is beyond normal usage
defined in this product manual.
Before installation, switch off the external circuit (that supplies power to the system).
Before connecting the equipment to power supply, ensure the output voltage is within the specified
range.
Never connect the product to the power before completion of installation.
Installation Cautions
1. To protect the wiring from rats, all wires should be placed in pipes. It is recommended to use PVC
conduits or galvanized tubes. Although the control panel has a good anti-static, anti-lightning,
and anti-leakage design, it is important to ensure that the case of the control panel and the AC
ground wire are connected perfectly and the AC ground wire is grounded.
2. It is recommended not to plug and unplug connection terminals frequently when the system is
energized. Be sure to unplug the connection terminals before starting any relevant welding job.
3. Do not detach or replace any control panel chip without permission because unprofessional
operation may cause damage to the control panel.
4. It is recommended not to connect any other auxiliary devices without permission. All non-routine
operations must be confirmed with our engineers in advance.
5. A control panel should not share one power socket with any other large-current devices.
6. It is preferable to install card readers and buttons at a height of 55 inches to 59 inches (1.4m to
1.5m) above the ground, subject to proper adjustment according to customers’ usual practice.
7. It is advised to install the product in a place convenient for future maintenance, like a weak
electric well.
8. The exposed part of any connection terminal is strongly recommended not be longer than 0.16
inches (4mm). Professional clamping tools may be used to avoid short-circuit or communication
failure resulting from accidental contact with excessive exposed wires.
9. To save access control event records, exterminal data periodically from control panels.
10. Prepared countermeasures against unexpected power failure, like selecting power supply with
UPS.
11. If the RS485 reader is connected externally and shares the power supply with the device (The
control panel does not supterminal RS485 readers with fingerprint verification function), the
connection between the EXT RS485 terminal and the reader is recommended not to be longer
than 328 ft (100m). Otherwise, it is recommended to use a separate power supply for the reader.
12. The length of the connection between computer and elevator controller: RS485 communication is
less than 3937 ft (1200m). In order to make the communication more stable, it is recommended
to control within 2624 ft (800m). It is recommended to use the power supply delivered with the
system as the control panel power supply.
13. It is recommended to use the power supply delivered with the system as the control panel power
supply.
14. In a place with strong magnetic interference, galvanized steel pipes or shielded cables are recommended,
and proper grounding is required.
2 Overview
System Introduction
The elevator control system is a digital management system that controls access to elevators for
personnels. This elevator control system introduced by ZKTeco mainly consists of the EC16 master
elevator controller, DEX16 floor expansion board, QR600 series reader and D147 card issuer and other
auxiliary equipment. Each elevator controller can be connected to up to seven floor expansion boards,
which can control up to 128 floors. After entering the elevator, users must swipe the card, QR code or
password inside the elevator to pass the authentication before they are authorized to press the
designated floor button and finally reach the corresponding floor.
EC16 elevator master controller is a bare board, which can be installed and fixed to Package C enclosure, and
the DEX16 expansion board supports stacking and fixing on the master control board.
No. Description
1 Status Indicator (Includes PWR, COMM, RUN)
2 Keyhole
3 Wire Hole
4 Heat Dissipation Holes
Technical Parameters
When the EC16 elevator controller is powered on, the LED indicators under normal circumstances will
show the following.
3 Terminal Instructions
Figure 3-1 Terminal diagram of the elevator controller and the expansion board
2 Extend Port 1 Expansion output for connecting DEX16 expansion board to expand floors.
Elevator Door
6 1 Used to connect the door closing button on the elevator operation panel.
Closing Button
Elevator Door
7 1 Used to connect the door opening button on the elevator operation panel.
Opening Button
Used to connect the voice control magic box to realize voice contact-free
10 Voice 1
elevator ride.
13 It is used to connect the fire switch, after starting the fire button, all the keys of
FIRE 1
the elevator cannot be lit normally.
In an emergency, when the emergency interface receives a short-circuit signal,
Emergency the elevator control will not control the elevator keys, and the equipment can
14 1
Button only be restored to the control state if it is powered off and restarted or set by
software.
When the manual interface receives a short-circuit signal, the elevator control
15 Manual Button 1 will not control the elevator keys, and the elevator will resume the control state
after release.
16 12V power supply terminal, used to connect the Package C enclosure matching
Power Input 1
adapter to power the elevator controller.
17 Ethernet Interface
1 Used for equipment networking and remote control.
(LAN1)
18 TCP/IP Reader
1 Used to connect TCP/IP multimodal intelligent collection terminal.
Interface (LAN2)
21 Floor Button
16 Used for connecting elevator extension floor buttons for floor selection control.
Control Port
22 Set the RS-485 address of the expansion board according to the current connection
DIP Switch 1
order of the expansion board and follow the operation prompt next to it.
23 Used to connect the signal output terminal of the EC16 controller (i.e. Extend
RS-485 Input 1
Port) or the signal output terminal of the upper level DEX16.
24 RS-485 Output 1 Used for output when connecting to DEX16 expansion floor.
4 Wiring Description
Note: Make sure the power is turned off before wiring. Wiring in the energized state may cause serious
damage to the equipment.
This device uses the adapter matched with the Package C enclosure to supply power to the elevator
controller, providing a 12V power supply which takes into account the power consumption of the
elevator controller itself, the power consumption of up to seven DEX16 expansion boards and the
output power consumption of the RS-485 reader. The wiring is shown in the following diagram.
Connect the elevator controller and the computer software via Ethernet cable. The wiring is shown in
the following diagram.
Figure 4-5 Swipe card to select the floor and direct selection of floor wiring diagram
Instruction:
S1 and S2 switches are two relays (S1 relay is normally closed and S2 relay is normally open) of the elevator
control board respectively. S1 is disconnected after power on, and S1 is closed after swiping the layer
selection card, then the elevator button can be lit by pressing; S2 is closed after swiping the direct access
card, then the elevator button will be lit automatically.
2. When the EMG interface becomes short circuit, the elevator controller will cancel the key control of
each floor. To cancel the "emergency" function, please log in ZKBio CVSecurity software, click
[Elevator] > [Elevator Device] > [Real-time Monitoring] > [Emergency interface recovery button].
3. When the FIRE interface becomes a short circuit, all the keys of the elevator cannot be lit normally. If
you want to cancel the "fire" function, please log in ZKBio CVSecurity software, click [Elevator] >
[Elevator Device] > [Device] and then check the equipment that needs to restart, select [Control] >
[Restart device] to complete the restart of the elevator control equipment, see the following figure for
detailed steps.
4. When the TAMPER interface becomes a broken circuit, the system will push the tampering alarm
information in real time and send an alarm sound.
5. Fire and emergency functions require no software setup, just a hardware connection for use.
6. In this elevator controller system, the fire interface has the highest level, followed by the emergency
interface, and finally the manual interface.
7. When an alarm is connected to the auxiliary output of the controller, the status of the alarm and the
event description of the software side after the interface is short circuit or broken circuit are as follows.
Interface Line Status Auxiliary Output (Alarm) Event description on the software
Real-time pushing of "manual button short circuit" information
Short circuit Uninterrupted alarm
and one alarm sound
MO Real-time pushing of "manual button short circuit" information
Broken circuit Stop alarm
and one alarm sound
Note: The alarm can be canceled by disconnecting the "manual" interface of the elevator control equipment.
Real-time pushing of "emergency button short circuit"
Short circuit Uninterrupted alarm
information and one alarm sound
The elevator management system consists of two parts, which are the management workstation (PC)
and the elevator controller. The management workstation and elevator controller adopt TCP/IP
communication mode. The communication line is as far away from the high-voltage electric line as
possible, and should not be wired in parallel with the power line, let alone bundled together.
The management workstation is a PC connected to the network, and the elevator manager can realize
various remote management functions, including adding/removing users, viewing various event
records, entering/exiting elevators and monitoring the status of each elevator in real time, etc. just by
running the elevator control management software on it.
The following diagram shows the installation of EC16 elevator controller system.
The elevator controller needs to be connected to the software and set the corresponding parameters
to use the elevator control function in the software system, and can manage the equipment through
the system, upload the user's elevator control data, download the configuration information and
output various reterminals to realize the digital management of the enterprise.
1. Open your browser, enter the server IP address and terminal number (e.g. https://127.0.0.1:8098/)
in the address bar, click Enter to enter the login page.
2. Or double-click the desktop the ZKBio CVSecurity icon to bring up the system login page.
3. For the first time to use this system, default user name admin and password admin, click [Login],
or click [Fingerprint Login] on the interface, then press the administrator finger on the
fingerprint device to enter the system home page.
4. To use this system for the first time, enter the default user name admin and password admin and
click [Login]. Or click the icon of Other login mode on the interface, then press admin finger
on the fingerprint device to enter the system home page.
Note:
1. To ensure the safety of using the system, you must change the default password after logging into the
system.
2. For more details, please refer to the ZKBio CVSecurity User Manual.
4. Click the [Add] button after the device and make sure to finish adding it.
Note:
When the device cannot be added to the software, please check the following information.
1. When the device can not be added, please check whether the communication is HTTP or HTTPS.
2. Whether PC and Elevator control device can PING through.
3. Whether the corresponding server IP of the device is correct.
1. Click [Elevator] > [Elevator Device] > [Expanding Board] to enter the setting interface.
2. Click[New] to add a expanding board.
3. Click [Device Name] and select the expansion board in the pop-up window.
4. Select the expansion board and then click to move it to the selected column on the right.
5. Click [OK] to confirm and exit.
6. After setting all parameters, click [OK] on the New page, when the pop-up "The operation
succeeded!" prompt means add extension board is completed.
Note: The RS485 address is input according to the dip switch setting of the expansion board, check the dip
switch setting in 4.6 Wiring of Expansion Board for details.
2) Select the reader and click [Edit] icon behind it to enter the editing screen.
3) Change the communication type of the reader to RS485 in the edit window and enter the RS485
address.
4) Click [OK] to confirm and exit, as shown in the figure below.
3. Each EC16 can connect a maximum of eight RS-485 readers, as shown in the figure below.
Remarks:
When connecting the RS-485 readers through the RS-485 communication terminal of the elevator
controller, it can provide a maximum current output of 3A (12V), so when using the power output of
the RS-485 communication terminal to supply power to multiple readers, the overall working current
of the reader cannot exceed this value and should be left with sufficient margin. In the calculation, the
maximum current for each reader is calculated (Note: the instantaneous current of the device at the
time of start-up is the largest, which can be more than twice the normal work, and this situation must
be considered when calculating). In addition, if the reader shares power with the device, it is
recommended that the RS-485 communication terminal and the RS-485 reader should not be
connected to more than 3937 ft (100m), otherwise it is recommended that a separate power supply be
used.
Note: For devices with high power consumption, it is recommended to use separate power supply to ensure
stable operation of the device.
Note:
Elevator Levels, Set Access By Levels, Set Access By Person and Set Access By Department function are mainly
used as visitor authority.
5. Click [Add Floor] icon in the levels group bar to open the settings window.
6. Select the floor and then click to move it to the selected column on the right.
7. Click [OK] to confirm and exit.
2. Check the levels group and click the [Add to Levels] icon in its bar to open the settings window.
3. Select the levels group and then click to move it to the selected column on the right.
4. Click [OK] to confirm and exit.
2. Check the department and click the [Add to Default Levels] icon in its bar to open the
settings window.
3. Select the levels group and then click to move it to the selected column on the right.
4. Click [OK] to confirm and exit.
You can set a direct selection floor for users or visitors here; or set other floors that can be selected in
addition to the direct selection floor.
1. Click [Elevator] > [Elevator Control Rule] > [Direct Selection Set] to set the floor that can be
reached directly for personnel.
2. Click the query icon to search the list of editable personnel.
3. Check the people you need to set in the list, and click icon to add direct access to the floor for
the people.
4. In the Add direct selection layer pop-up window, click on the drop-down menu to select the
elevator device, direct floor and time zones.
Select Floor
1. In the pop-up window of Add direct selection layer, click [Click to select] in the select floor
column to select the floor.
2. Once the setup is complete, the user is allowed to access the authorized floor. Once the user is
authenticated at the reader, he/she can press his/her authorized floor button directly on the floor
panel to light up that floor.
When the QR-600 Series Reader successfully communicates with the elevator controller (see 5.1.5 Add
Reader on the Software for details on the connection method), the user can verify on the QR-600 series
reader.
Users can authenticate with passwords, cards and QR codes on the QR-600 series reader. When the
verification is successful, the user can reach the authorized floor.
When a user or visitor is authorized to go straight to the floor, the authorized floor is directly lit when
he verifies successfully.
When a user or visitor is authorized to reach multiple floors, when he verifies successfully, he needs to
manually light up the authorized floor to reach it.
Note: Unauthorized floors will not respond when the user presses the floor button.
Employees can install ZKBioSecurity Mobile App on the mobile phone, and can use the QR code of the
electronic work card on the app to verify on QR-600 series reader to automatically light up the direct
floor or manually light up the optional floor. The specific operation steps are as follows.
5. Open the App on the Smartphone. On the login screen, tap [Server Setting] and type the IP
Address or the Domain Name of the Server, and its Port Number.
6. Tap the QR Code icon to scan the QR code of the new App client. After the client is identified
successfully, set the Client Name and tap [Testing Connection].
7. After the network is connected successfully, tap [Save].
Note: The APP's network connection and the server's network connection need to be in the same LAN,
otherwise the network will be unavailable.
5.3.2 Login
Initially, it is required to configure the Server Settings before login. After the Server settings are
successfully saved, it will automatically return to the login screen.
1. Select the login identity which includes Administrator login and Employee login.
2. The default is "Admin". When the Employee needs to login, tap on Employee to switch to
Employee login screen.
3. The administrator can login with the username in [System] > [Authority Management] > [User]
and self-service password. The default self-service password is 111111.
4. Employees can login with the Personnel ID in [Personnel] > [Personnel] > [Person] and self-
service password. The default self-service password is 123456.
6. The Administrator and Employee can change the Password in the App System Settings.
Notes: The license determines the number of available Mobile App connections. Users can view it by clicking
[Personal Information] > [About Path], as shown below.
7. Each registration code consumes a licensed App point and can only be assigned to one mobile
phone.
1. Select Employee and enter the account information, then click Login to enter the App.
3. Place this QR code in front of the QR code collector of the reader for verification.
6 Communication Connection
The backend PC software is able to communicate with the system via TCP/IP for data exchange and
remote management. Communication lines are as far away from high-voltage power lines as possible,
and should not be wired in parallel with power lines, let alone bundled together.
TCP/IP Communication
The Ethernet 10/100Base-T Crossover Cable, a type of crossover network cable, is mainly used for
cascade hubs and switches, or used to connect two Ethernet end-points directly without a hub. Both
10Base-T and 100Base-T are supterminaled.
1. In ZKBio CVSecurity software, click [Elevator] > [Elevator Device] >[Device] to enter the setting
interface.
2. Click [Search] to open the Search interface in the software.
3. After the search is completed, a list of controllers will be displayed. Select the controller in the list
and click [Add] behind the action bar.
4. In the Add window, enter the relevant parameters for the controller.
5. Click [OK] to save and exit.
6. The factory default IP address of the device is: 192.168.1.201, after the device is added successfully,
you can modify the IP address of the device in the communication column. Select the device, click
[Elevator] > [Elevator Device] > [Set up] > [Modify IP Address], modify the IP address of NIC 1
and click [OK].
The default IP address of the primary NIC when the elevator controller is shipped is 192.168.1.201. It
may conflict with the IP of other devices in the network, so the new device needs to modify the IP
address before use. It can be modified by the following ways.
1. After logging in the ZKBio CVSecurity software, click [Elevator] > [ElevatorDevice] > [Device] >
[Search], click [Download Search Tools to Local Disk] in the search device window, download
the search tool deviceSettingTool_overseas.exe to your computer.
Note: At the bottom of the search device interface will prompt the current system communication
terminal number.
3. Select the device to be modified, click the icon to modify the IP address of the device, click
[OK] after setting the parameters, as the following figure shows.
Old IP Address: The IP address of the device. The factory default IP address of the device is:
192.168.1.201.
New IP Address: The new IP address of the device. Note: The IP address of the device and the IP
address of the computer must be in the same network segment.
Subnet Mask: Default subnet mask 255.255.255.0, can be modified as needed.
Gateway: Default gateway address 0.0.0.0, can be modified as needed. Note: The gateway and
the IP address must be in the same network segment.
Access Server IP: The IP address of the ZKBio CVSecurity software server.
Access Server Port: Enter the communication terminal number of the current system, which is
indicated under the "Search" pop-up window.
After adding devices successfully in the software (see 5.1.2 Add Device on the Software), you can
change the IP address in the device list field.
1. Click [Elevator] > [Elevator Device] > [Device] to enter the setting interface.
2. Check the added device in the device list.
3. Click [Set up] > [Modify IP address] to bring up the settings window.
Note: Network card 1 is the IP address of the primary NIC of the elevator controller, and Network card 2 is the
IP address of the extended NIC of the elevator controller.
7 Others
USB interface can be used to upgrade the elevator controller, the usage is as follows.
1. First, create a new “Udisk” folder in the USB disk, and put the upgrade file into “Udisk”.
2. Under the normal operation of the elevator controller, insert the U disk, press the [Reset] key for 1
to 5 seconds (the operation light will flash) and release it.
3. The operation light will keep flashing during the upgrade process (no power failure during the
upgrade, no unplugging of the U disk), and the elevator controller will restart automatically after
the upgrade is successful.
4. If the upgrade is unsuccessful, the elevator controller will return to normal operation.
The EC16 elevator controller can be restored to factory settings by [RESET] key. Press the [RESET]
button, 1 to 5 seconds to upgrade with USB disk, 5 to 10 seconds to restart the controller, 10 seconds
or more to restore the factory settings.
Note: When restoring the factory settings, only the network configuration of the device is restored,
and other data is not restored.
Data transfer error 1 short sound 1 long LED indicator (red) lights up
(Wiegand format error) sound one short and then once long.
I. Collected Information
To ensure the normal product operation and help the service improvement, we will collect the
information voluntarily provided by you or provided as authorized by you during registration and
use or generated as a result of your use of services.
1. User Registration Information: At your first registration, the feature template (Fingerprint
template/Face template/Palm template) will be saved on the device according to the
device type you have selected to verify the unique similarity between you and the User ID you
have registered. You can optionally enter your Name and Code. The above information is
necessary for you to use our products. If you do not provide such information, you cannot use
some features of the product regularly.
2. Product information: According to the product model and your granted permission when
you install and use our services, the related information of the product on which our services
are used will be collected when the product is connected to the software, including the
Product Model, Firmware Version Number, Product Serial Number, and Product Capacity
Information. When you connect your product to the software, please carefully read the
privacy policy for the specific software.
1. When you use our products for the first time, you shall set the Administrator privilege before
performing specific operations. Otherwise, you will be frequently reminded to set the
Administrator privilege when you enter the main menu interface. If you still do not set the
Administrator privilege after receiving the system prompt, you should be aware of the
possible security risk (for example, the data may be manually modified).
2. All the functions of displaying the biometric information are disabled in our products by
default. You can choose Menu > System Settings to set whether to display the biometric
information. If you enable these functions, we assume that you are aware of the personal
privacy security risks specified in the privacy policy.
3. Only your user ID is displayed by default. You can set whether to display other user
verification information (such as Name, Department, Photo, etc.) under the Administrator
privilege. If you choose to display such information, we assume that you are aware of the
potential security risks (for example, your photo will be displayed on the device
interface).
4. The camera function is disabled in our products by default. If you want to enable this function
to take pictures of yourself for attendance recording or take pictures of strangers for access
control, the product will enable the prompt tone of the camera. Once you enable this
function, we assume that you are aware of the potential security risks.
5. All the data collected by our products is encrypted using the AES 256 algorithm. All the data
uploaded by the Administrator to our products are automatically encrypted using the AES
256 algorithm and stored securely. If the Administrator downloads data from our products,
we assume that you need to process the data and you have known the potential security risk.
In such a case, you shall take the responsibility for storing the data. You shall know that some
data cannot be downloaded for sake of data security.
6. All the personal information in our products can be queried, modified, or deleted. If you no
longer use our products, please clear your personal data.
Our products, website and services are mainly designed for adults. Without consent of parents or
guardians, minors shall not create their own account. If you are a minor, it is recommended that
you ask your parents or guardian to read this Policy carefully, and only use our services or
information provided by us with consent of your parents or guardian.
We will only use or disclose personal information of minors collected with their parents' or
guardians' consent if and to the extent that such use or disclosure is permitted by law or we have
obtained their parents' or guardians' explicit consent, and such use or disclosure is for the purpose
of protecting minors.
Upon noticing that we have collected personal information of minors without the prior consent
from verifiable parents, we will delete such information as soon as possible.
IV. Others
The product's "eco-friendly operational period" refers to the time during which this product
will not discharge any toxic or hazardous substances when used in accordance with the
prerequisites in this manual.
The eco-friendly operational period specified for this product does not include batteries or
other components that are easily worn down and must be periodically replaced. The
battery's eco-friendly operational period is 5 years.
Hazardous/Toxic Substance/Element
Chip Resistor × ○ ○ ○ ○ ○
Chip Capacitor × ○ ○ ○ ○ ○
Chip Inductor × ○ ○ ○ ○ ○
Diode × ○ ○ ○ ○ ○
ESD
component
× ○ ○ ○ ○ ○
Buzzer × ○ ○ ○ ○ ○
Adapter × ○ ○ ○ ○ ○
Screws ○ ○ ○ × ○ ○
○ indicates that the total amount of toxic content in all the homogeneous materials is below the limit
as specified in SJ/T 11363—2006.
× indicates that the total amount of toxic content in all the homogeneous materials exceeds the limit
as specified in SJ/T 11363—2006.
Note: 80% of this product’s components are manufactured using non-toxic and eco-friendly
materials. The components which contain toxins or harmful elements are included due to the current
economic or technical limitations which prevent their replacement with non-toxic materials or
elements.