Technical and Vocational Training Institute

Bahir Dar Satellite Campus


Faculty of Civil Technology; Department of Construction Technology

Academic Year: 2015 Exam Item: Closed


Book and Open book
Course Title: Reinforced Concrete - I Mode of Examination: Final
Exam
Course Code: BCTe 4025 Exam Date: Feb 19, 2023
Stream: Building Construction Technology Time Allowed:
3:00 Hrs
Target Group: Building Con. Tech 3rd Year Instructor:
Habtamu Tilahun
Semester: III

Name: ID No: section:


Program: Regular CEP Summer Year: 1st 2nd 3rd 4th
5th

INSTRUCTIONS TO THE CANDIDATES:


[1] Write your Name and ID No in space provided before answering the questions.
[2] Make sure the booklet consists 2 pages of question sheets and 6 pages of blank
sheet excluding this cover page.
[3] The answers for exam Item - I, (closed book part), must be written on the space
provided under each questions.
[4] Brief and to the point answers using necessary sketches will be appreciated.
[5] Any candidate found coping will be subject to Disciplinary Action under the
relevant rules.
[6] Use of mobile phone and programmable calculator is totally prohibited in
the examination hall.
[7] Make suitable assumptions whenever necessary.

FOR EVALUATION FILED ONLY BY INSTRUCTOR


Marks Obtained
Part - I Part - II
Total Continuous
Question 1–5 6–7 Total
Final Ass
Number (10%) (40%) (100%)
(50%) (50%)
Marks
Obtained
Technical and Vocational Training Institute
Bahir Dar Satellite Campus
Faculty of Civil Technology; Department of Construction Technology

Approved by:

Examination Committee(s) – Instructor (s) Signature


Date

1) _________________________________ ____________ ____________

2) _________________________________ ____________ ____________

3) _________________________________ ____________ ____________

Chairman - Department head Signature


Date

__________________________________ ____________ ____________

Part-I Short Answer – (closed book) Time allowed: 20min

1. List and discuss the types of flexural failure in beam. (2pts)

2. What is ductile beam and how ductility can be ensured? (2pts)

3. What are the two failure modes of beam under shear force? (2pts)

4. List at least four reasons for providing compression reinforcement. (2pts)


Technical and Vocational Training Institute
Bahir Dar Satellite Campus
Faculty of Civil Technology; Department of Construction Technology

5. Write the primary reasons that we provide cover (concrete between the surface of the slab
or beam and the reinforcing bars). (2pts)

Part-II Workout – (Open book) Time allowed: 2:40hrs

6. Figure 1 below is a first floor plan of a reinforced concrete office building. During construction,
slabs and beams are cast monolithically. The overall thickness of the RC solid slab is required to be
150 mm. Given that a characteristic live load of 3kN/m 2, the design life = 50 years, fire resistance =
REI 60, exposure class = XC1, characteristic concrete strength = C25/30, high yield steel strength =
S-450 N/mm2 and diameter of reinforcement = 10 mm.
a) Design the reinforcement and show schematic detailing for slab panel-1. (10pts)
b) Find the load transferred from slab to the abeam axis-1. (4pts)
c) Check the deflection requirement for panel-1 and write your judgment. (5pts)

Fig.1 First floor plan


7. The beam cross-section shown in figure 2 is intended to resist the design moment 75KNm and the
design shear force 40kN. The concrete grade and reinforcing steel grade used is C30/35 and S450
respectively. Moment redistribution is not required.
a) Determine the number of flexural reinforcement if ∅ 16 bar is used. (10pts)
b) Design a shear reinforcement if ∅ 8 link bar is used. (7pts)
c) Show the beam section detailing. (4pts)
Technical and Vocational Training Institute
Bahir Dar Satellite Campus
Faculty of Civil Technology; Department of Construction Technology

Fig.2 beam section