Catalogi Ulka Bombas
Catalogi Ulka Bombas
Catalogi Ulka Bombas
DOUBLE INSULATED
MODELS
EP
EX
450 58 20 E5 650 15
USCITA IN OTTONE BRASS OUTLET E5D 300 60 15 EK 700 16 EK2 E7 1000 67,8 7 E77 900 4 E8 E8S 1200 73 2,5 E8R 650 58 2,2 E8LT 1100 55,5 2
64,5
67,2
65,8
1200 60
2,5
EVOLUTION PUMP Alternating current Self-priming at 0 bar Suitable to dry-use only during priming Integrated diode Ideal fluid:water
Non idonea allutilizzo a secco tranne che per i normali interventi di innesco Faston 6.3 x 0,8 Diodo integrato
Autoinnescante a pressione 0
A joint making the pump indipendent from the hydraulic connection at the delivery is provided Computer-based production and inspection Thermal cutout pocket
VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C
Models EP4, EP5, EP7, EP5 D EAP4, EAP5, EAP7, EAP5 D EP4, EP5, EP7, EP5 D EAP4, EAP5, EAP7, EAP5 D EFP4, EFP5, EFP7, EFP5 D EP4, EP5, EP7, EP5 D EX4, EX5, EX7, EX5 D EAX4, EAX5, EAX7, EAX5 D EX4, EX5, EX7, EX5D EAX4, EAX5, EAX7, EAX5 D EFX4, EFX5, EFX7, EFX5 D EX4, EX5, EX7, EP5 D Voltage
E
E5
MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C
E4
240V~50Hz 230V~50Hz 220V~50Hz 220V~60Hz 200V~50-60Hz 120V~60Hz 120V~60Hz 120V~60Hz 100V~50-60Hz 24V~50-60Hz
ON/OFF (min) 2/1 2/1 2/1 1/2 2/1 1/1 1/1,5 2/1 2/1 2/1
E7
Class F F F A F A A F F F
W 48 48 48 64 48 41 52 52 55 48
E4
E5
E5D
E7
Voltage
E4FM
230V~50Hz 120V~60Hz
E5FM
Class F F
W 46 40
E4FM
E5FM
VIBRATION PUMPS
DOUBLE INSULATED
Models EK2 EK Voltage 220V~50Hz 230V~50Hz
E
-
MODELS
EK
EK2
Class F F
W 56 54
EK
EK2
ER
Class F F
W 42 46 46
1/1
E4R
E8R
VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C
E
E77
MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C
Class F F
W 28 27 31 35
Certificates VDE UL --
100%
100%
A F
E77
Models
Voltage
E8
E8S
Class F F
W 33 28 26 29
100%
100%
28
E8 - E8S
Per funzionamento continuo. E8S anche a secco fino a 30 minuti. Suitable for continuous working. E8S even up-to-30-minute dry-working.
VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C
MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C
E 8 LT
Class F F
W 23 20
E 8 LT
Per funzionamento continuo senza termoprotettore, anche a secco! Suitable for continuous working without thermal protection, even dry!
S C H E M A D I P R O VA - T E S T P R O C E D U R E
Drawing showing the ideal junction and hydraulic seal to be applied at the delivery of the pump type E
Schema di connessione e tenuta idraulica ideale da applicare alla mandata delle pompe E
VIBRATION PUMPS
EVOLUTION MICROPUMP
NME
Class F
ON/OFF
(min) 100% 100% 100% 100% 100%
NME 2 110 40
NME 3 90
NME 4 50
Voltage
50 60 60 50-60 50-60
Hz
16 16 16 16 16
2,5
2,5 39
2,5 36
20-:30 1 -
NME 5 (*)
NME1
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
NME1C
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
VIBRATION PUMPS
EVOLUTION MICROPUMP
V=Vn - Water 20C - Ambient temperature 25C
NME
NME1S
Flow rate/Time:
Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar
Cold Performance:
Heating test:
NME2
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
NME3
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
NME3S
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
NME4
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Flow rate/Time:
Heating test:
VIBRATION PUMPS
HIGH-PRESSURE MICROPUMP
NMEHP
Class F
Voltage available and Relative Certification
Integrated Diode 1 N 4007 1000V Without Diode, description: ND Voltage Hz 230-240 50 120 60 220 60 100 50-60 24 50-60 Tolerancy +/- 15% ON/OFF (min) 100% 100% 100% 100% 100% W 21 17 21 21 17 Certificates VDE c-UR -
VIBRATION PUMPS
HIGH-PRESSURE MICROPUMP
NMEHP3
V=Vn - Water 20C - Ambient temperature 25C
NMEHP
NMEHP4
V=Vn - Water 20C - Ambient temperature 25C
Cold Performance:
Cold Performance:
V=Vn+6C-p=0 Bar
NMEHP1S
Class F
10
VIBRATION PUMPS
HIGH-FLOW MICROPUMP
HF
MODELS
Models
HF
Class F F F
W 22 23
HF
2/1
2/1
22
22
Double Insulation
HF
11
VIBRATION PUMPS
HIGH-FLOW MICROPUMP
HF2
MODELS
Models
HF2
HF2
Class F
W 18
Certificates -
18
Double Insulation
HF2
ND=Without integrated Diode in case the pumps is supplied by an electronic management T=110C Max at V=Vn+6% - ED 100% - p=0 bar
12
FITTING
E - NME - NMEHP - HF
FITTING
MODELS
FITTING
NMEHP M O D E L S
FITTING
NME
MODELS
FITTING
HF
MODELS
FITTING
MODELS
FITTING MODELS
HF
13
14
EVOLUTION PUMP
Doppio isolamento Alimentazione a corrente alternata come da dati di targa Fluido ideale: acqua alla temperatura di 25C Funzionamento e potenza assorbita secondo dati di targa Autoinnescante purch priva di contropressione alla mandata; prevalenza 3mt Non idonea allutilizzo a secco tranne che per i normali interventi di innesco La bobina dotata di un marsupio per ospitare un eventuale termoprotettore I componenti sono sottoposti a severi controlli di qualit La produzione e il collaudo sono effettuati da un impianto automatizzato e computerizzato che ne garantisce e certifica la qualit nonch la indispensabile tempestivit devasione degli ordini. Le prove al 100% comprendono: 1) Prova di rigidit dielettrica verso massa a 2500V per 2 secondi 2) Prova di idraulica, di innesco, di portata, di pressione Double insulation AC supply as per label data Ideal fluid: water at 25C (maximum temperature) Working time and absorbed power as per label data Self-priming without counterpressure at delivery head; 3 mt height Suitable to dry-use only during priming The coil is equipped with a pocket for the possible fitting of a thermal cutout The components are subjected to strict quality controls Both production and test are carried out by an automated and computerised system assuring and certifying not only its quality but also the indispensable promptness in executing orders. The full detailed inspection includes: 1) Dielectric strenght test towards mass at 2500V per 2 seconds 2) Hydraulic, Self-priming, Flow-rate and Pressure Tests
15
R e v. 0 1 d e l 0 1 . 2 0 0 8