Catalogi Ulka Bombas

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

VIBRATION PUMPS

DOUBLE INSULATED

MODELS

EP

USCITA IN PLASTICA PLASTIC OUTLET Models E4 E4R 350 60 9

EX
450 58 20 E5 650 15

USCITA IN OTTONE BRASS OUTLET E5D 300 60 15 EK 700 16 EK2 E7 1000 67,8 7 E77 900 4 E8 E8S 1200 73 2,5 E8R 650 58 2,2 E8LT 1100 55,5 2

Average Flow Rate (cc/min) Noise [dB(A)] at p=0 Bar/20cm

Average Pressure (Bar)

15,5 67,2 650

64,5

67,2

65,8

1200 60

2,5

POMPA EVOLUZIONE Fluido ideale: acqua Corrente alternata

EVOLUTION PUMP Alternating current Self-priming at 0 bar Suitable to dry-use only during priming Integrated diode Ideal fluid:water

Non idonea allutilizzo a secco tranne che per i normali interventi di innesco Faston 6.3 x 0,8 Diodo integrato

Autoinnescante a pressione 0

Raccordo uscita snodato Tasca per termoprotettore

A joint making the pump indipendent from the hydraulic connection at the delivery is provided Computer-based production and inspection Thermal cutout pocket

Electrical connections: 6.3 x 0,8

Test elettrici e idraulici al 100%

Produzione e collaudo automatizzati e computerizzati

Full detailed electrical and hydraulic inspection

VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C
Models EP4, EP5, EP7, EP5 D EAP4, EAP5, EAP7, EAP5 D EP4, EP5, EP7, EP5 D EAP4, EAP5, EAP7, EAP5 D EFP4, EFP5, EFP7, EFP5 D EP4, EP5, EP7, EP5 D EX4, EX5, EX7, EX5 D EAX4, EAX5, EAX7, EAX5 D EX4, EX5, EX7, EX5D EAX4, EAX5, EAX7, EAX5 D EFX4, EFX5, EFX7, EFX5 D EX4, EX5, EX7, EP5 D Voltage

E
E5

MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C

E4

240V~50Hz 230V~50Hz 220V~50Hz 220V~60Hz 200V~50-60Hz 120V~60Hz 120V~60Hz 120V~60Hz 100V~50-60Hz 24V~50-60Hz

ON/OFF (min) 2/1 2/1 2/1 1/2 2/1 1/1 1/1,5 2/1 2/1 2/1

E7

Class F F F A F A A F F F

W 48 48 48 64 48 41 52 52 55 48

Certificates IMQ IMQ/VDE IMQ c-UL c-UL c-UL c-UL -

E4

E5

E5D

E7

Models EP4FM-EP5FM EP4FM-EP5FM

Voltage

E4FM

230V~50Hz 120V~60Hz

ON/OFF (min) 2/1 2/1

E5FM

Class F F

W 46 40

Certificates VDE c-UL

Temporary - Values to be set up - Tolerancy +/- 15%

E4FM

E5FM

VIBRATION PUMPS
DOUBLE INSULATED
Models EK2 EK Voltage 220V~50Hz 230V~50Hz

E
-

MODELS

EK

ON/OFF (min) 1/1 1/1

EK2

Class F F

W 56 54

Certificates IMQ/VDE IMQ

EK

EK2

Models EP4R, EP8R EX4R, EX8R

Voltage 230V~50Hz 100V~50-60Hz 120V~60Hz

ER

ON/OFF (min) 1/1 1/1

Class F F

W 42 46 46

Certificates VDE c-UL -

1/1

E4R

E8R

VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C

E
E77

MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C

Models EP77 EX77

Voltage 220V~50-60Hz 100V~50-60Hz 120V~60Hz 230V~50Hz

ON/OFF (min) 100% 100%

Class F F

W 28 27 31 35

Certificates VDE UL --

100%

100%

A F

E77

Models

Voltage

E8

230V-240V~50Hz EP8, EP8S EX8, EX8S 220V~50-60Hz 100V~50-60Hz 24V~50Hz 120V~60Hz

ON/OFF (min) 100% 100% 100%

E8S

Class F F

W 33 28 26 29

Certificates VDE c-UL ---

100%

100%

28

E8 - E8S
Per funzionamento continuo. E8S anche a secco fino a 30 minuti. Suitable for continuous working. E8S even up-to-30-minute dry-working.

VIBRATION PUMPS
DOUBLE INSULATED
Prestazione a bobina fredda V=Vn Temperatura ambiente 25C Fluido: acqua a 20C

MODELS
Cold coil performances V=Vn Room temperature at 25C Fluid: water at 20C

Models EP8LT EX8LT

Voltage 230-240V~50Hz 120V~60Hz

E 8 LT

ON/OFF (min) 100% 100%

Class F F

W 23 20

Certificates VDE c-Ul

E 8 LT
Per funzionamento continuo senza termoprotettore, anche a secco! Suitable for continuous working without thermal protection, even dry!

S C H E M A D I P R O VA - T E S T P R O C E D U R E

Drawing showing the ideal junction and hydraulic seal to be applied at the delivery of the pump type E

Schema di connessione e tenuta idraulica ideale da applicare alla mandata delle pompe E

VIBRATION PUMPS
EVOLUTION MICROPUMP

NME

Voltage available and Relative Certification


230-240 220 120 100 24

Class F
ON/OFF
(min) 100% 100% 100% 100% 100%

Integrated Diode 1 N 4007 1000V Without Diode, description: ND TYPES


Certificates
VDE c-UR -

NME 1 200 2,5 50

NME 1C 220 2,0 44

NME 1S 180 3,2 51

NME 2 110 40

NME 3 90

NME 4 50

Voltage

50 60 60 50-60 50-60

Hz

16 16 16 16 16

Average Flow-rate (cc/min) dB(A) at p=0 Bar/20cm Max pressure (Bar)

2,5

2,5 39

2,5 36

20-:30 1 -

NME 5 (*)

NME1
V=Vn - Water 20C - Ambient temperature 25C

(*) Temporary - Values to be set up - Tolerancy +/- 15%

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

NME1C
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

VIBRATION PUMPS
EVOLUTION MICROPUMP
V=Vn - Water 20C - Ambient temperature 25C

NME
NME1S
Flow rate/Time:
Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Heating test:

NME2
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

NME3
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

NME3S
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

NME4
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

Flow rate/Time:

Water 20C - Ambient temp. 25C V=Vn+6%-p=0 Bar

Heating test:

VIBRATION PUMPS
HIGH-PRESSURE MICROPUMP

NMEHP

Class F
Voltage available and Relative Certification

Integrated Diode 1 N 4007 1000V Without Diode, description: ND Voltage Hz 230-240 50 120 60 220 60 100 50-60 24 50-60 Tolerancy +/- 15% ON/OFF (min) 100% 100% 100% 100% 100% W 21 17 21 21 17 Certificates VDE c-UR -

NMEHP1 Cold Performance:

NMEHP2 Cold Performance:

V=Vn - Water 20C - Ambient temperature 25C

V=Vn - Water 20C - Ambient temperature 25C

VIBRATION PUMPS
HIGH-PRESSURE MICROPUMP
NMEHP3
V=Vn - Water 20C - Ambient temperature 25C

NMEHP
NMEHP4
V=Vn - Water 20C - Ambient temperature 25C

Cold Performance:

Cold Performance:

Heating test: Water 20C - Ambient temperature 25C

V=Vn+6C-p=0 Bar

NMEHP1S

Class F

Cold Performance: V=Vn - Water 20C - Ambient temperature 25C


Integrated Diode 1 N 4007 1000V Without Diode, description: ND Voltage 230-240 Hz 50 ON/OFF (min) 1/1 W 16 Certificates VDE

Voltage available and Relative Certification

10

VIBRATION PUMPS
HIGH-FLOW MICROPUMP

HF

MODELS

Models

Voltage 230V~50Hz 100V~50-60Hz 220V~60Hz 120V~60Hz

HF

ON/OFF (min) 2/1 2/1

Class F F F

W 22 23

Certificates VDE c-Ul -

HF

2/1

2/1

22

22

Double Insulation

HF

Self-priming without counterpressure

Suitable to dry-use only during priming

ND=Without integrated Diode in case the pumps is supplied by an electronic management

T=110C Max at V=Vn+6% - 2 min ON/1 min OFF - p=0 bar

11

VIBRATION PUMPS
HIGH-FLOW MICROPUMP

HF2

MODELS

Models

Voltage 230V~50Hz 120V~60Hz

HF2

HF2

ON/OFF (min) 100% 100%

Class F

W 18

Certificates -

Temporary - Values to be set up

18

Double Insulation

HF2

Self-priming without counterpressure

Suitable to dry-use only during priming

ND=Without integrated Diode in case the pumps is supplied by an electronic management T=110C Max at V=Vn+6% - ED 100% - p=0 bar

12

FITTING

E - NME - NMEHP - HF
FITTING

MODELS

FITTING

NMEHP M O D E L S

FITTING

NME

MODELS

FITTING

HF

MODELS

FITTING

MODELS

FITTING MODELS

HF

13

14

EVOLUTION PUMP
Doppio isolamento Alimentazione a corrente alternata come da dati di targa Fluido ideale: acqua alla temperatura di 25C Funzionamento e potenza assorbita secondo dati di targa Autoinnescante purch priva di contropressione alla mandata; prevalenza 3mt Non idonea allutilizzo a secco tranne che per i normali interventi di innesco La bobina dotata di un marsupio per ospitare un eventuale termoprotettore I componenti sono sottoposti a severi controlli di qualit La produzione e il collaudo sono effettuati da un impianto automatizzato e computerizzato che ne garantisce e certifica la qualit nonch la indispensabile tempestivit devasione degli ordini. Le prove al 100% comprendono: 1) Prova di rigidit dielettrica verso massa a 2500V per 2 secondi 2) Prova di idraulica, di innesco, di portata, di pressione Double insulation AC supply as per label data Ideal fluid: water at 25C (maximum temperature) Working time and absorbed power as per label data Self-priming without counterpressure at delivery head; 3 mt height Suitable to dry-use only during priming The coil is equipped with a pocket for the possible fitting of a thermal cutout The components are subjected to strict quality controls Both production and test are carried out by an automated and computerised system assuring and certifying not only its quality but also the indispensable promptness in executing orders. The full detailed inspection includes: 1) Dielectric strenght test towards mass at 2500V per 2 seconds 2) Hydraulic, Self-priming, Flow-rate and Pressure Tests

15

COFFEE DIVISION CEME Spa


Registered Office CEME Spa Via Camperio, 9 - 20123 Milano - ITALY Headquarters and Production Site: Via dellArtigianato, 6 - 27050 RETORBIDO - PV - ITALY Tel. +39 03833724.1 - Fax +39 0383 74149 e-mail: [email protected] - www.ulka.it

R e v. 0 1 d e l 0 1 . 2 0 0 8

w w w. c i b s . i t

You might also like