JC International Limited: Defect / Non Compliance Report

This document contains two defect reports from JC International Limited, an inspection company. The first report details a crack found at the base of a 10.3/4” – 9.5/8’’ casing bowl during magnetic particle inspection. The second report describes a crack found on the handle of a 2.7/8’’ tubing center elevator during magnetic particle inspection. Both items were inspected for surface breaking defects and failed inspection due to the cracks found.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
96 views2 pages

JC International Limited: Defect / Non Compliance Report

This document contains two defect reports from JC International Limited, an inspection company. The first report details a crack found at the base of a 10.3/4” – 9.5/8’’ casing bowl during magnetic particle inspection. The second report describes a crack found on the handle of a 2.7/8’’ tubing center elevator during magnetic particle inspection. Both items were inspected for surface breaking defects and failed inspection due to the cracks found.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


Certificate No. Date of Examination Examiner Qualifications

1883 Identification Number

15/07/11 Description of Equipment:

SIMON OGBAN

SNT LEVEL II (MT, PT & UT)

10.3/4 9.5/8 CASING BOWL (BUSHING)

154787.0

METHOD: All Accessible Load Bearing Areas were cleaned to bare metal and inspected based on the specification and the test procedure stipulated below for surface breaking defects RESULTS: Crack was found at the base as at the time of inspection.
SPECIFICATION : BS MPI METHOD: RESULTS:

EN ISO 9934-1:2001, API RP 8B

TEST PROCEDURE:

JOP-020

Wet Visible Crack was found at the base.

MAGNETIC FIELD INDICATOR: BURMAH CASTROL STRIP ILLUMINATION: 1000 LUX TEST TEMPERATURE: 28 DEGREE CELSIUS.

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS Contrast Media: White contrast paint Indicator: Black magnetic ink

Name and address of equipment owner:

Address of premises where Test / Examination was held:

KCA DEUTAG

KCA DEUTAG STACKING AREA (T 41) SIMON OGBAN

We hereby certify that on 15/07/11 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Name of Inspector:

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


Certificate No. Date of Examination Examiner Qualifications

1898 Identification Number

26/07/11

SIMON OGBAN

SNT LEVEL II (MT, PT & UT)

Description of Equipment: 2.7/8

TUBING CENTER ELEVATOR

DIMENSIONS

E672 (031471095) (087805.7)

Right Ear: 3.5/8 Left Ear: 3.5/8 Top Bore: N/A Middle Bore: N/A Bottom Bore: N/A Hinge Gap dia.: 1/4 Door Gap dia.: 2/32

SPRING CONDITION- OK
SHOULDER CONDITION- OK MANUFACTURER: BJ YT

METHOD: All Accessible Load Bearing Areas were cleaned to bare metal and inspected based on the specification and the test procedure stipulated below for surface breaking defects RESULTS: Crack was found on the handle as at the time of inspection.
SPECIFICATION : BS MPI METHOD: RESULTS:

EN ISO 9934-1:2001, API RP8B

TEST PROCEDURE:

JOP-020

Wet Visible Crack was found at the Handle.

MAGNETIC FIELD INDICATOR: BURMAH CASTROL STRIP ILLUMINATION: 1000 LUX TEST TEMPERATURE: 28 DEGREE CELSIUS.

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS Contrast Media: White contrast paint Indicator: Black magnetic ink

Name and address of equipment owner:

Address of premises where Test / Examination was held:

KCA DEUTAG

KCA DEUTAG STACKING AREA (T 41) SIMON OGBAN

We hereby certify that on 26/07/11 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Name of Inspector:

Cert No.227173

You might also like