IDEC EU2B Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

30mm Hazardous Location Switches EU2B Series:


30mm Hazardous Location Switches
EC2B Series: Hazardous Location Control Stations
Key features:
• Pre-configured stations
• Custom-configured stations
• Open control boxes
• Mounting holes for up to 18 control units
• Class I, Zone 1/Division 2
Signaling Lights

• Applicable in explosive gas atmospheres (AEx de IIC T6 Gb)


• UL Type 4X rated
• Up to 3 contact blocks
• Selector switches available with lever or key
• Selector switches available with overlapping contacts
• Exposed and finger-safe (IP20) screw terminals available
• Corrosion resistant stainless steel enclosure (SUS304)
Relays & Sockets

• Melamine coating
• NPT and Metric reducer options
IECEx is pending approval

Specifications
Standards Compliance
Switches Pilot Lights Meters Control Boxes
Class I, Zone 1 AEx d e IIC T6 Gb
UL
Class I Div 2, Groups A, B, C and D
Class I, Zone 1, Ex de IIC T6 Gb Class I, Zone 1, Ex de IIB T6 Gb Class I, Zone 1, Ex de IIC T6 Gb
c-UL
Timers

Class I, Div 2, Groups A, B, C and D Class I, Div 2, Groups C and D Class I, Div 2, Groups A, B, C and D
II2G Ex de IIC Gb Ex d e IIC T6 Gb
ATEX
II2D Ex tb IIIC Db IP65 Ex tb IIIC T80ºC Db (dust)
Ex de IIC Gb Ex de IIC T6 Gb
IECEx
Ex tb IIIC Db IP65 Ex tb IIIC T80ºC Db (dust)

Certificate Numbers
Contactors

UL/c-UL ATEX IECEx


PTB 08 ATEX 1053 U IECEx PTB 15.0006U
E347230 PTB 08 ATEX 1003 U IECEx PTB 15.0007U
PTB 08 ATEX 1048 IECEx PTB 15.0032

Applicable Standards
Control Units Standards Mark

EN60947-5-1
Terminal Blocks

UL60079-0
Pushbuttons
UL60079-1
Selector
UL60079-7
Switches
Key Selector CAN/CSA C22.2 No. 60079-0
CAN/CSA C22.2 No. 60079-1
Switches CAN/CSA C22.2 No. 60079-7
Pilot Lights EN60079-0 EN60079-1
Meters EN60079-7 EN60079-31
IEC60079-0 IEC60079-1
IEC60079-7 IEC60079-31
Circuit Breakers

Emergency
EN60947-5-5
Stop Switches

750 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


General Specifications
Degree of Protection IP65 (IEC60529), Type 4X
Insulation Resistance 100 MΩ minimum (500V DC megger)
Operating Temperature −20 to +50°C (no freezing)
Operating Humidity 45 to 85% (no condensation)
Altitude 2,000m Maximum
Pollution Degree 3
Operating Extremes 100-m/s² Emergency Stop Switch: 150-m/s² (without Meter)
Shock Resistance
Damage Limits 1000-m/s²

Signaling Lights
5 to 55-Hz, amplitude 0.5 mm Emergency Stop Switch: 5 to 500-Hz, amplitude 0.35-mm, acceleration 50-m/s²
Operating Extremes
Vibration Resistance (without Meter)
Damage Limits 30Hz, amplitude 1.5-mm Emergency Stop Switch: 5 to 500-Hz, amplitude 0.35-mm, acceleration 50-m/s²

Switches
Rated Insulation Voltage 600V
Contact Resistance 50mΩ maximum (initial value)
Impulse Withstand Voltage (Uimp) 6kV

Relays & Sockets


Insulation Resistance 100MΩ minimum (500V DC megger)
Short-Circuit Protection 250V/10A fuse (Type aM IEC60269-1/IEC60269-2)
Conditional Short-Circuit Current 1,000A
Pushbutton 1,000,000 operations minimum
Selector Switch 500,000 operations minimum
Mechanical Life
Key Selector Switch 500,000 operations minimum
Emergency Stop Switch 50,000 operations minimum
Pushbutton 250,000 (switching frequency 1800 operations/hr)
Selector Switch 250,000 (switching frequency 900 operations/hr)

Timers
Electrical Life
Key Selector Switch 250,000 (switching frequency 900 operations/hr)
Emergency Stop Switch 50,000 (switching frequency 900 operations/hr)
Minimum Operator Stroke Required for Direct Opening Action Emergency Stop Switch 7.0mm
Maximum Operator Stroke Emergency Stop Switch 9.0mm

Note: Contacts will bounce during operation of pushbuttons and selector switches (reference value: 20-ms). Be sure to take contact bounce time into consideration when designing a control circuit.

Contact Rating (Switches)

Contactors
Rated Insulation Voltage (Ui) 600V
Rated Thermal Current (Ith) 10A*
Rated Operating Voltage (Ue) 24V 120V 240V 500V
Resistive Load (AC12) 10A* 10A* 6A 2.8A
AC 50/60Hz
Inductive Load (AC15) 10A* 6A 3A 1.4A
Rated Operating Current (Ie)
Resistive Load (DC12) 8A 2.2A 1.1A —
DC
Inductive Load (DC13) 4A 1.1A 0.55A —

Terminal Blocks
Note: Up to 2 contacts (per control unit): 10A 3 contacts (per control unit): 9A Minimum applicable load: 3V AC/DC, 5mA Applicable operating locations may vary according to operating conditions and load types.

Maximum current, Amperes Maximum Volt-Amperes


120 Volt 240 Volt 480 Volt 600 Volt 600 Volt
Contact Rating Code Thermal Continuous
Designation Test Current Amperes
Make Break Make Break Make Break Make Break Make Break

A600 10 60 6.00 30 3.00 15 1.5 12 1.2 7200 720


Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 751
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Pilot Lights
Rated Insulation Voltage (Ui) 500V
Voltage 6V, 12V, 24V AC/DC
Rated Operating Voltage (Ue)
Transformer 120V, 230V, 240V, 380V, 480V AC
Impulse Withstand Voltage (Uimp) 4kV
Insulation Resistance 100 MΩ minimum (500V DC)
Frequency 50/60Hz
Full Voltage 0.3W
Power Consumption (approx.)
Transformer 1.5W
Signaling Lights

Life (reference value) Approx. 40,000 hours

Note: Because the built-in LED lamp is a high-brightness version, the lamp may light dimly due to induction even when power is off.

Meters
Accuracy Class 2.5
Insulation Resistance 100 MΩ minimum (500V DC megger)
Rated Insulation Voltage (Ui) 300V
Operation Moving core
Relays & Sockets

AC ammeter

Impulse Withstand Voltage (Uimp) 4kV


Power Consumption 1VA
Measurement 5A, 10A, 30A, 50A, etc
Input (CT Ratio) 1A, 5A
Extended Memory 3 times, etc
Rated Insulation Voltage (Ui) 150V
Operation Moving coil
DC input meter

Impulse Withstand Voltage (Uimp) 2.5kV


Input 0 to10V DC, 4 to 20mA, etc.
Timers

Power Consumption (DC ammeter) 0.15W


Consumption Current (DC voltmeter) 1mA
Note: Use a commercially available CT (current transformer) for all AC ammeters, and install the CT in a non-hazardous location.

Control Boxes
Degree of protection IP65 (IEC60529), Type 4X Agency Approvals UL/c-UL, IECEx/ATEX certified
Housing Material Stainless steel (SUS304) Applicable Enclosure All enclosures except for 6 Control Units x 3 Column
Melamine Mounting Style Wall Mount
Contactors

Standard Coating 1-column: Outside coating Pilot Light Yes1


2-, 3-column: Inside and outside coating
Pushbutton Yes
600V (with pilot light or ET2A-8PE screw terminal
Control Unit

block: 500V) Emergency Pushbutton Yes


Rated Insulation Voltage
Meter AC input: 300V Selector Switch Yes
Meter DC input: 150V
Key Selector Switch Yes
Insulation Resistance 100 MΩ minimum (500V DC megger)
Meter Yes
Operating Temperature −20 to +50°C (no freezing)
NPT Thread (standard)
Terminal Blocks

Operating Humidity 45 to 85% (no condensation) Reducer Screw


Metric Thread
Altitude 2000m maximum
Degree of Protection IP65, TYPE4X (UL)
Grounding Terminal Screw Material Stainless Steel
Stranded Wire (mm2) 1.5 to 2.5
Applicable
Wire

Solid Wire (mm2) 1.2 to 1.6


Solid/Stranded Wire (AWG) 16-14
Circuit Breakers

1: c-UL explosion protection is different when pilot light is installed.

752 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Switches (Control Units)

Pushbuttons Emergency Stop Switches Pilot Lights Selector Switches Key Selector Switches Meters

Signaling Lights
Pushbuttons Pilot Lights
EU2B - YB1 11 F S - D EU2B - YL1 22 F D R
Operator (style / function) Button color Operator (style / function) Lens/LED Colors
B1 : Flush pushbutton / Momentary Contact arrangement Blank: Red, Green, Black, L1 : Pilot Light / dome R : Red G : Green A : Amber
B2 : Extended pushbutton / Momentary 10 : 1NO 01 : 1NC and White included Y : Yellow PW : White S : Blue
Operating voltage
B3 : Mushroom pushbutton / Momentary 20 : 2NO 02 : 2NC Y : Yellow S : Blue
Terminals
30 : 3NO 03 : 3NC 126 : AC 120V (Transformer type) 66 : AC/DC 6V (Full voltage type)
Terminals
246 : AC 240V (Transformer type) 11 : AC/DC 12V (Full voltage type) F : Finger-safe terminal (IP20)
11 : 1NO-1NC 12 : 1NO-2NC F : Finger-safe terminal (IP20)
C : Exposed screw terminal 386 : AC 380V (Transformer type) 22 : AC/DC 24V (Full voltage type) C : Exposed screw terminal
21 : 2NO-1NC
486 : AC 480V (Transformer type)
Contact

Relays & Sockets


Style and Weight
Part Number Arrange- ➀ Button Color
Function (Approx.)
ment
Operating Weight ➀ Illumination
Part Number Type
EU2B-YB110➃➀–D 1NO Voltage (Approx.) Color Code
68g
EU2B-YB101➃➀–D 1NC ➀ Blank - sup- EU2B-YL1126➃D➀ 120V AC
EU2B-YB111➃➀–D 1NO-1NC plied with red,
green, black, and EU2B-YL1236➃D➀ 230V AC R : red
EU2B-YB120➃➀–D 2NO 92g white buttons Trans-
Flush Momen- EU2B-YL1246➃D➀ 240V AC 150g G : green
EU2B-YB102➃➀–D 2NC former
tary EU2B-YL1386➃D➀ 380V AC A : amber
EU2B-YB121➃➀–D 2NO-1NC For yellow or Y : yellow
blue buttons, EU2B-YL1486➃D➀ 480V AC PW : white
EU2B-YB112➃➀–D 1NO-2NC specify Y (yellow) S : blue
116g EU2B-YL166➃D➀ 6V AC/DC
EU2B-YB130➃➀–D 3NO or S (blue). Full Volt-

Timers
EU2B-YL111➃D➀ 12V AC/DC 108g
EU2B-YB103➃➀–D 3NC age
EU2B-YL122➃D➀ 24V AC/DC
EU2B-YB210➃➀–D 1NO
70g Note: ➀ Illumination Color. Specify a contact terminal style in place of ➃ in the part number: F (Finger-safe
EU2B-YB201➃➀–D 1NC terminal), C (Exposed screw terminal)

EU2B-YB211➃➀–D 1NO-1NC
EU2B-YB220➃➀–D 2NO 94g
Extended
EU2B-YB202➃➀–D 2NC
Momentary Specify a button
EU2B-YB221➃➀–D 2NO-1NC color code in

Contactors
EU2B-YB212➃➀–D 1NO-2NC place of ➀ in the
118g part number
EU2B-YB230➃➀–D 3NO
EU2B-YB203➃➀–D 3NC B : black
EU2B-YB310➃➀–D 1NO G : green
76g R : red
EU2B-YB301➃➀–D 1NC
S : blue
EU2B-YB311➃➀–D 1NO-1NC W : white
EU2B-YB320➃➀–D 2NO 101g Y : yellow

Terminal Blocks
Mushroom
EU2B-YB302➃➀–D 2NC
Momentary
EU2B-YB321➃➀–D 2NO-1NC
EU2B-YB312➃➀–D 1NO-2NC
125g
EU2B-YB330➃➀–D 3NO
EU2B-YB303➃➀–D 3NC
Note: ➀ Button Color. Specify a contact terminal style in place of ➃ in the part number: F (Finger-safe terminal), C
(Exposed screw terminal)
Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 753
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Emergency Stop Switches


EU2B - YBV3 11 F R
Operator (style / function) Contact arrangement Button color
BV3 : 40mm mushroom/push, pull or 01 : 1NC R : Red
twist release 11 : 1NO-1NC
Terminals
02 : 2NC
F : Finger-safe terminal (IP20)
03 : 3NC
C : Exposed screw terminal
12 : 1NO-2NC

Contact Weight
Part Number Operator Button Color
Arrangement (Approx.)
Signaling Lights

EU2B-YBV301➃R 1NC 96g


EU2B-YBV311➃R 1NO-1NC
120g
EU2B-YBV302➃R ø40 Mushroom 2NC R : Red
EU2B-YBV312➃R 1NO-2NC
144g
EU2B-YBV303➃R 3NC

Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal)

Meters
Relays & Sockets

EU2B - YM 5 3 A 10 F R EU2B - YM 010 VD F-PER-R


Function Set pointer Function Set pointer
M : Meter blank : non -R : with set pointer M : Meter blank : non -R : with set pointer
Input current Input voltage or current Specification of scale
1 : 1A 5 : 5A 010 : 0-10V Type of meter
Terminals 001 : 0-1mA -PER : 0~100%
Specification of overload scale F : Finger-safe terminal (IP20)
VD : DC voltmeter
420 : 4-20mA etc. -60HZ : 0~60Hz
3: 3 times 2 : 2 times 5 : 5 times N:Non C : Exposed screw terminal MD : DC ammeter
Type of meter Terminals -80HZ : 0~80Hz
A : AC ammeter Measuring range F : Finger-safe terminal (IP20)
Direct measuring  1 : 1A    5 : 5A C : Exposed screw terminal
For current transformers: 10 : 10A  15 : 15A  20 : 20A   30:30A   50:50A
  60 : 60A  75 : 75A 100:100A 150:150A  
Timers

Input Part Number Description Weight (approx.)

EU2B-YM53A5➃ Capacity: 5A Expansion scale: x3


EU2B-YM53A10➃ Capacity:10/5A Expansion scale: x3
EU2B-YM13A10➃ Capacity:10/1A Expansion scale: x3
EU2B-YM53A15➃ Capacity:15/5A Expansion scale: x3
EU2B-YM13A15➃ Capacity:15/1A Expansion scale: x3
Contactors

EU2B-YM13A20➃ Capacity:20/1A Expansion scale: x3


AC input meter EU2B-YM53A30➃ Capacity:30/5A Expansion scale: x3
(ammeter)
EU2B-YM13A30➃ Capacity:30/1A Expansion scale: x3
EU2B-YM53A50➃ Capacity:50/5A Expansion scale: x3
EU2B-YM53A60➃ Capacity:60/5A Expansion scale: x3
270g
EU2B-YM53A75➃ Capacity:75/5A Expansion scale: x3
EU2B-YM53A100➃ Capacity:100/5A Expansion scale: x3
Terminal Blocks

EU2B-YM53A150➃ Capacity:150/5A Expansion scale: x3


EU2B-YM010VD➃-PER 0-10V DC Input Scale: 0 to 100%
EU2B-YM010VD➃-60HZ 0-10V DC Input Scale: 0 to 60Hz
EU2B-YM001MD➃-PER 0-1mA DC Input Scale: 0 to 100%
DC input meter EU2B-YM001MD➃-60HZ 0-1mA DC Input Scale: 0 to 60Hz
EU2B-YM001MD➃-80HZ 0-1mA DC Input Scale: 0 to 80Hz
EU2B-YM420MD➃-PER 4-20mA DC Input Scale: 0 to 100%
Circuit Breakers

EU2B-YM420MD➃-60HZ 4-20mA DC Input Scale: 0 to 60Hz


Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal)

754 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


2 Position Selector Switches
EU2B - YSK 3 11 N1 F A
Operator (style / function) Key Removable Position
S : Selector (Knob operator) Contact arrangement See option codes below
SK: Key selector (Key operator) 10 : 1NO 03 : 3NC
11 : 1NO-1NC 02 : 2NC Terminals
Number of Positions / Spring Return Action
01 : 1NC 21 : 2NO-1NC F : Finger-safe terminal (IP20)
2 : 2-position / Maintained 3 : 3-position / Maintained
30 : 3NO 12 : 1NO-2NC C : Exposed screw terminal
2R : 2-position / Maintained (Overlap) 31 : 3-position / Spring return from right
20 : 2NO
2J : 2-position / Maintained (Special function) 32 : 3-position / Spring return from left Circuit Number
21 : 2-position / Spring return from right 33 : 3-position / Spring return two-way Blank : No Designation
N* : See charts

Selector Switches Key Selector Switches Selector Key Selector

Signaling Lights
Spring Switches Switches
Operator Spring Return
Maintained Return from Maintained Operator
Position from Right Maintained Maintained
Con- Mount- Right Position
tact ing Mount-
L R L R L R L R L R Contact
ing L R L R L R

NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
EU2B-YS210➃ EU2B-
YS2110➃ YSK210➃➂ YSK2110➃➂ EU2B-YS2J10➃
YSK2J10➃➂

Relays & Sockets


EU2B- EU2B- EU2B-
EU2B-YS201➃ EU2B-
YS2101➃ YSK201➃➂ YSK2101➃➂ EU2B-YS2J01➃
NC 3 ● YSK2J01➃➂
NC 3 ●
NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
EU2B-YS220➃ EU2B-
YS2120➃ YSK220➃➂ YSK2120➃➂ EU2B-YS2J20➃
NO 3 ● YSK2J20➃➂
NO 3 ●
NC 1 ●
EU2B- EU2B- EU2B- NC 1 ●
EU2B-YS202➃ EU2B-
YS2102➃ YSK202➃➂ YSK2102➃➂ EU2B-YS2J02➃
NC 3 ● YSK2J02➃➂

Timers
NC 3 ●
NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
EU2B-YS211➃ EU2B-
YS2111➃ YSK211➃➂ YSK2111➃➂ EU2B-YS2J11➃
NC 3 ● YSK2J11➃➂
NC 3 ●
NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
NO 2 ● EU2B-YS230➃
YS2130➃ EU2B-
YSK230➃➂ YSK2130➃➂ NO 2 ● EU2B-YS2J30➃
NO 3 ● YSK2J30➃➂
NO 3 ●
NC 1 ●
EU2B- EU2B- NC 1

Contactors
EU2B- ●
NC 2 ● EU2B-YS203➃
YS2103➃ EU2B-
YSK203➃➂ YSK2103➃➂ NC 2 ● EU2B-YS2J03➃
NC 3 ● YSK2J03➃➂
NC 3 ●
NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
NO 2 ● EU2B-YS221➃
YS2121➃ EU2B-
YSK221➃➂ YSK2121➃➂ NO 2 ● EU2B-YS2J21➃
NC 3 ● YSK2J21➃➂
NC 3 ●
NO 1 ●
EU2B- EU2B- EU2B- NO 1 ●
NC 2 ● EU2B-YS212➃
YS2112➃ EU2B-
YSK212➃➂ YSK2112➃➂ NC 2 ● EU2B-YS2J12➃

Terminal Blocks
NC 3 ● YSK2J12➃➂
NC 3 ●
NO 1
EU2B- EU2B-
YS2R11➃
N/A N/A
YSK2R11➃➂
NC 2
Key is removable in all maintained positions. Specify key removal position in place of ➂ in the part number. See table.
Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal).
2-position, 2-position/inverse cam ➂ Key Removable Option Codes (2-position)
Selector Switch Key Selector Switch
A Key removable in any position
Circuit Breakers

L R L R
B Key removable in left position
j j Contact
Contact C Key removable in right position
k Block Block
Position
k Position
l
l

1705151134
800-262-IDEC (4332) • USA & Canada 755
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

3 Position Selector Switches


Selector Switches Key Selector Switches
Spring Return Spring Return Spring Return Spring Return Spring Return Spring Return
Operator Position Maintained Maintained
from Right from Left Two Way from Right from Left Two Way
Contact Mounting
L C R L C R L C R L C R L C R L C R L C R L C R L C R

NO 1 ●
EU2B- EU2B- EU2B- EU2B-
EU2B-YS320➃ EU2B-YS3120➃ EU2B-YS3220➃ EU2B-YS3320➃
YSK320➃➂ YSK3120➃➂ YSK3220➃➂ YSK3320➃➂
NO 3 ●
Signaling Lights

NO 2 ● ● EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-


YS320N1➃ YS3120N1➃ YS3220N1➃ YS3320N1➃ YSK320N1➃➂ YSK3120N1➃➂ YSK3220N1➃➂ YSK3320N1➃➂
NO 3 ●
NC 1
EU2B- EU2B- EU2B- EU2B-
EU2B-YS302➃ EU2B-YS302➃ EU2B-YS3202➃ EU2B-YS3302➃
YSK302➃➂ YSK302➃➂ YSK3202➃➂ YSK3302➃➂
NC 3

EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-


NC 2 ●
YS302N1➃ YS3102N1➃➂ YS3202N1➃➂ YS3302N1➃ YSK302N1➃➂ YSK3102N1➃➂ YSK3202N1➃➂ YSK3302N1➃➂
NC 3
Relays & Sockets

NO 1 ●
EU2B- EU2B- EU2B- EU2B-
EU2B-YS311➃ EU2B-YS311➃ EU2B-YS3211➃ EU2B-YS3311➃
YSK311➃➂ YSK311➃➂ YSK3211➃➂ YSK3311➃➂
NC 3
NC 1
EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-
YS311N1➃ YS3111N1➃ YS3211N1➃ YS3311N1➃ YSK311N1➃➂ YSK3111N1➃➂ YSK3211N1➃➂ YSK3311N1➃➂
NO 3 ●
NO 1 ●
EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-
NC 2 ●
YS311N2➃ YS3111N2➃ YS3211N2➃ YS3311N2➃ YSK311N2➃➂ YSK3111N2➃➂ YSK3211N2➃➂ YSK3311N2➃➂

NC 2 ● EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-


Timers

YS311N3➃ YS3111N3➀ YS3211N3➀ YS3311N3➀ YSK311N3➃➂ YSK3111N3➃➂ YSK3211N3➃➂ YSK3311N3➃➂


NO 3 ●

NO 2 ● ● EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-


YS311N4➃ YS3111N4➃ YS3211N4➃ YS3311N4➃ YSK311N4➃➂ YSK3111N4➃➂ YSK3211N4➃➂ YSK3311N4➃➂
NC 3
NO 1 ●
EU2B- EU2B- EU2B- EU2B-
NO 2 ● ● EU2B-YS330➃ EU2B-YS3130➃ EU2B-YS3230➃ EU2B-YS3330➃
YSK330➃➂ YSK3130➃➂ YSK3230➃➂ YSK3330➃➂
NO 3 ●
NC 1
Contactors

EU2B- EU2B- EU2B- EU2B-


NC 2 ● EU2B-YS303➃ EU2B-YS3103➃ EU2B-YS3203➃ EU2B-YS3303➃
YSK303➃➂ YSK3103➃➂ YSK3203➃➂ YSK3303➃➂
NC 3
NO 1 ●
EU2B-YS3 EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-
NC 2 ●
21N1➃ YS3121N1➃ YS3221N1➃ YS3321N1➃ YSK321N1➃➂ YSK3121N1➃➂ YSK3221N1➃➂ YSK3321N1➃➂
NO 3 ●
NC 1
EU2B-YS3 EU2B- EU2B- EU2B- EU2B- EU2B- EU2B- EU2B-
NO 2 ● ●
12N1➃ YS3112N1➃ YS3212N1➃ YS3312N1➃ YSK312N1➃➂ YSK3112N1➃➂ YSK3212N1➃➂ YSK3312N1➃➂
NC 3
Terminal Blocks

Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal). Key is removable in all maintained positions. Specify key removal position in
place of ➂ in the part number. See table.

3-position, 3-position/inverse cam ➂ Key Removable Option Codes (3-Position)


Selector Switch Key Selector Switch
A Key removable in any position
C C
L R L R B Key removable in left and center positions
j j C Key removable in center and right positions
Contact Contact
Circuit Breakers

k Block
Position
k Block
Position
D Key removable in center position
l l
E Key removable in left and right positions
G Key removable in left position
H Key removable in right position)

756 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Control Boxes

1Column
1 control unit 2 control units 3 control units 4 control units 5 control units
EC2B-B21B011N2➀-U EC2B-B21B021N2➀-U EC2B-B31B031N2➀-U EC2B-B51B041N3➀-U EC2B-B51B051N3➀-U

Signaling Lights
2 Columns
4 control units 6 control units 8 control units 10 control units
EC2B-B32B042N2➀-U EC2B-B32B062N2➀-U EC2B-B52B082N3➀-U EC2B-B52B102N3➀-U

Relays & Sockets


3 Columns
6 control units 9 control units 12 control units 15 control units 18 control units

EC2B-B33B063N2➀-U EC2B-B33B093N2➀-U EC2B-B53B123N3➀-U EC2B-B53B153N3➀-U EC2B-B63B183N3➀-U

Timers
Thread Size ➀ Terminal Block Style
Code Description Code Description
M1 M16 blank no terminal block

Contactors
M2 M20 C Exposed screw terminals
M3 M25 F Finger-safe terminals
M4 M32
M5 M40
N1 NPT1/2 Other thread size options available. To specify different thread
N2 NPT3/4 sizes, use table at left to select a code to use in place of N2 or
N3 in the part number.
N3 NPT1 Specify terminal block style in place of ➀ in part number
NPT1 (standard versions do not contain a terminal block).
N4
1/4

Terminal Blocks
Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 757
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Standard Control Stations


1 Control Unit × 1 Column
1 pushbutton 1 selector switch

31
1 3
j OFF ON
j
Signaling Lights

42 2 4

EC2B-1102BN2N1-U EC2B-1102BN2N2-U
Flush momentary EC2B-1106BN2N1-U
1NO contact Flush momentary
Nameplate ON 1NC contact

Button color: black, green, red, and Nameplate OFF Knob selector
OFF ON
white Button color: black, green, red, and white 2-position maintained

Relays & Sockets

1NO-1NC contact 1NO-1NC contact


Name plate OFF-ON
EC2B-1102BN2N3-U EC2B-1102BN2N4-U
Flush momentary
Flush momentary
1NO-1NC contact 1 key selector switch
1NO-1NC contact
➀ Nameplate ON
Nameplate OFF
Button color: black, green, red, and
white
Button color: black, green, red, and white 1 3
OFF ON
j
1 pilot light
Timers

2 4

X1 X2 j
EC2B-1106BN2N4-U
Key selector
2-position maintained OFF ON
➀ (removable at all positions)
1NO-1NC contact
Nameplate OFF-ON
Contactors

EC2B-1101BN211-U EC2B-1101BN212-U EC2B-1101BN23-U


1 e-stop switch
120V AC 240V AC 24V AC/DC

Illumination color: red Illumination color: red Illumination color: red
1 1

EC2B-1101BN213-U EC2B-1101BN214-U EC2B-1101BN26-U j

2 2
Terminal Blocks

24V AC/DC
120V AC 240V AC
➀ Illumination color:
Illumination color: green Illumination color: green
green

EC2B-1102BN2N7-U

Emergency stop switch


2NC contact

Nameplate EMERGENCY STOP
Button color (red)
Circuit Breakers

758 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


2 Control Units × 1 Column
2 Control Units × 1 Column 2 Mushroom Pushbuttons

2 flush pushbuttons 3 1

3 j
4 2
j 3 1
4 k
1 4 2
k

Signaling Lights
2
Mushroom momentary
➀ 1NO-1NC contact, Nameplate ON
Flush momentary Button color (black)
➀ 1NO contact, Nameplate ON
Button color (black, green, red, white) Mushroom momentary
Flush momentary  1NO-1NC contact, Nameplate OFF
➁ 1NC contact, Nameplate OFF Button color (red)
Button color (black, green, red, white)

Relays & Sockets


1 pilot light/1 pushbutton

X1 X2 j
3 1
k

Timers
4 2

EC2B-2110BN2N5-U EC2B-2110BN2N6-U EC2B-2110BN2N3-U

120V AC 240V AC 24V AC/DC



Illumination color: red Illumination color: red Illumination color: red

Flush momentary Flush momentary Flush momentary

Contactors
1NO-1NC contact 1NO-1NC contact 1NO-1NC contact

Name plate STOP Name plate STOP Name plate STOP
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)

Specify terminal style code in place of  in part no. C (standard screw terminal), F (finger-safe screw terminal)

Terminal Blocks
Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 759
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

2 Control Units × 1 Column

1 pilot light / 1 selector switch

X1 X2 j
1 3
OFF ON
k
Signaling Lights

2 4

EC2B-2117BN2N3-U EC2B-2117BN2N4-U
120V AC 240V AC

Illumination color: red Illumination color: red

Knob, 2-position, OFF ON Knob, 2-position, OFF ON


➁ 1NO-1NC contact 1NO-1NC contact
Relays & Sockets

Maintained, Name plate OFF-ON Maintained, Name plate OFF-ON

3 Control Units × 1 Column

1 pilot light / 2 pushbuttons

X1 X2 j
4
Timers

k
3
2
l
1

EC2B-3110BN2N5-U EC2B-3110BN2N6-U EC2B-3110BN2N3-U


Contactors

120V AC 240V AC 24V AC/DC



Illumination color: red Illumination color: red Illumination color: red

Flush momentary Flush momentary Flush momentary


➁ 1NO contact, Nameplate ON 1NO contact, Nameplate ON 1NO contact, Nameplate ON
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)

Flush momentary Flush momentary Flush momentary


Terminal Blocks

➂ 1NC contact, Nameplate OFF 1NC contact, Nameplate OFF 1NC contact, Nameplate OFF
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)
Circuit Breakers

760 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


3 pushbuttons 1 meter / 2 pushbuttons
3 1
A j
j
4 2 3 1
3 1 k
k 4 2
4 2 3 1
3 1 l
l 4 2
4 2

Signaling Lights
EC2B-3152BN2N1-U
EC2B-3102BN2N1-U
➀ Specify input, capacity, and scale

Flush momentary Flush momentary
1NO-1NC contact, ➁ 1NO-1NC contact, Nameplate ON
➁ Blank nameplate Button color (black, green, red, white)
Button color (black, green, red, white)
Flush momentary
➂ ➂ 1NO-1NC contact, Nameplate OFF

Relays & Sockets


Button color (black, green, red, white)
Specify the meter’s capacity and scale in place of  in the part number

4 Control Units × 1 Column

2 pilot lights / 2 pushbuttons


X1 X2 j
X1 X2

Timers
k
3 1
l
4 2
3 1
m
4 2

Contactors
EC2B-4110BN3N5-U EC2B-4110BN3N6-U EC2B-4110BN3N3-U
➀ 120V AC, Illumination color: red 240V AC, Illumination color: red 24V AC/DC, Illumination color: red
➁ 120V AC, Illumination color: green 240V AC, Illumination color: green 24V AC/DC, Illumination color: green

Flush momentary Flush momentary Flush momentary


➂ 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)

Flush momentary Flush momentary Flush momentary

Terminal Blocks
➃ 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white) Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 761
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

1 pilot light / 2 pushbuttons / 1 selector switch

X1 X2 j
3 1
k
4 2
3 1 l

4 2
HAND AUTO m

1 3
Signaling Lights

EC2B-4113BN3N5-U EC2B-4113BN3N6-U EC2B-4113BN3N3-U

➀ 120V AC, Illumination color: red 240V AC, Illumination color: red 24V AC/DC, Illumination color: red

Flush momentary Flush momentary Flush momentary


➁ 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)
Relays & Sockets

Flush momentary Flush momentary Flush momentary


➂ 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)

Knob, 2-position, maintained HAND AUTO


Knob, 2-position, maintained HAND AUTO
Knob, 2-position, maintained HAND AUTO
➃ 1NO-1NC contact 1NO-1NC contact 1NO-1NC contact
Nameplate HAND-AUTO Nameplate HAND-AUTO Nameplate HAND-AUTO

5 Control Units × 1 Column


Timers

2 pilot lights / 2 pushbuttons / 1 selector switch


X1 X2 j
X1 X2
k
3 1
l
4 2
3 1
Contactors

m
4 2
2 4
OFF ON
n
1 3

EC2B-5113BN3N5-U EC2B-5113BN3N6-U EC2B-5113BN3N3-U

➀ 120V AC, Illumination color: red 240V AC, Illumination color: red 24V AC/DC, Illumination color: red
Terminal Blocks

➁ 120V AC, Illumination color: green 240V AC, Illumination color: green 24V AC/DC, Illumination color: green

Flush momentary Flush momentary Flush momentary


➂ 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON 1NO-1NC contact, Nameplate ON
Button color (black, green, red, white) Button color (black, green, red, white) Button color (black, green, red, white)

Flush momentary Flush momentary Flush momentary


➃ 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF 1NO-1NC contact, Nameplate OFF
Button color (black, green, red, white) Button color (black, green, red, white) Button color black, green, red, white)

Knob, 2-position, Main- HAND AUTO


Knob, 2-position, Main- HAND AUTO
Knob, 2-position, Main-
HAND AUTO
Circuit Breakers

➄ tained, 1NO-1NC contact, tained, 1NO-1NC contact tained, 1NO-1NC contact


Name plate HAND-AUTO Name plate HAND-AUTO Name plate HAND-AUTO

Specify terminal style code in place of  in part no. C (standard screw terminal), F (finger-safe screw terminal)

762 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Dimensions

Pushbuttons
Shown with finger-safe contacts

Flush

39.0
ø40

Signaling Lights
32.2 1.0 to 4.5
(panel thickness)
13.3 67.7
Mushroom
Extended
33.0
ø 40.0

48.0

ø 24.0
ø40

Relays & Sockets


13.3 67.7 24.5
19.3

Emergency Stop Switches


Shown with finger-safe contacts
ø 40.0

38.4

Timers
32.2
1.0 to 4.5 (panel thickness)
47.4
35.0 67.7
Selector Switches
Shown with finger-safe contacts

Contactors
ø 40.0

38.4

32.2 1.0 to 4.5 (panel thickness)

47.4 37.3 67.7

Terminal Blocks
Key Selector Switch
Shown with finger-safe contacts
ø 40.0

38.4

32.2 1.0 to 4.5


(panel thickness)
Circuit Breakers

47.4 27.3 67.7

Pilot Lights
Shown with finger-safe contacts

1705151134
800-262-IDEC (4332) • USA & Canada 763
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

ø 40.0

ø 40.0

62.0
32.0
32.5 1.0 to 4.5
(panel thickness) 20.3 67.7
61.4 20.3 67.7

Meters
Signaling Lights

Shown with finger-safe contacts


Mounting Hole Dimensions

50 minimum (*note)
ø 64.0
8.0

ø 28.0
+0.2
4.8 0 70 minimum

ø3
0.5
+0 0
.5
1.0 to 4.5

+0.5
33.5 62.1

33 0
(Panel thickness)
Relays & Sockets

Panel thickness: 1.0 to 4.5 mm.


*Note: The meter can be mounted on the top mounting holes of a
standard 50mm mounting centers. The meter can be mounted on any
mounting hole with a 70mm or larger mounting center.
Timers
Contactors
Terminal Blocks
Circuit Breakers

764 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


1, 2 control units x 1 column 2, 3, 4, 5 control units x 2 columns
weight: 1.2kg/1.4kg weight: 3.8/4.2/4.6/5.0 kg
115 4 control units
1 control unit 4-ø7 (mounting hole) 2 control units 70
110 230
70
95 10 6 1.5 220
(mounting 106 2
Mounting tab 210

50
hole)
Mounting tab

3×50P
(mountin g
4-ø10

hole )
170

100

142

(mounting
(mounting

hole)
2 control units hole)

R
3 control units

Signaling Lights
5 control units
50

Hinge Reducer Hinge


70 70

2×50P
M4 grounding terminal
M5 lid mounting screw Reducer

36.5
M4 grounding terminal
M5 lid mounting screw

4×50P
36

70 Dimensions
No. of A R
Control Units

2 or 3 250 180
3 control units x 1 column 2, 3, 4, 5 control units x 3 columns
4 or 5 350 280

Relays & Sockets


weight: 1.8kg weight: 4.8/5.2/6.5/7.1 kg
3 control units 2 control units 4 control units
115 140 140
2×50P

110 4-ø7 (mounting hole) 320


310
50

95 106 1.5 106 2


300
(mounting Mounting tab

3×50P
hole) Mounting tab

4-ø10

(mounting
(mounting hole)

hole)
3 control units
(mounting

R
5 control units
hole)
220

192
150

140
2×50P

140
Hinge

Timers
Reducer Reducer

36.5
Hinge
4×50P

M4 grounding terminal M4 grounding terminal


M5 lid mounting screw M5 lidDimensions
mounting screw
70 70 No. of A R
Control Units
36

2 or 3 250 180
4 or 5 350 280
4, 5 control units x 1 column 6 control units x 3 columns
weight: 2.4kg weight: 8.1kg

Contactors
115 320
4 control units 5 control units 4-ø7 (mounting hole) 310
110
106 1.5 300 106 2
95 Control Unit Mounting tab
4x40P

(mounting
hole) Mounting tab Mounting Holes
3x50P

140 4-ø10
(mounting
hole)
(mounting
5×50P

hole)
400

330
(mounting

Terminal Blocks
322
350

250
hole)

Hinge

Reducer
Hinge Reducer M4 grounding terminal
36.5

M4 grounding terminal
M5 lid mounting screw
M5 lid mounting screw
70 70
36

Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 765
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Terminal Blocks Fittings and Reducers


Terminal blocks are not supplied with the standard control boxes (without wir- Reducers installed at the bottom of the control box are as follows: 1 column: 1
ing). When wiring inside the control box is required, specify the wiring circuit. reducer, 2 columns: 2 reducers, 3 columns: 3 reducers. Material is nickel-plated
The terminal block type used on the control boxes with wiring depends on the brass. Use cable lead-in fittings that are commercially available. See the following
terminal style of the control unit. table for optional reducers.
C terminal style Control Box Style Part No. Thread Size Symbol UL c-UL
exposed screw terminal EC9E-H3M16E-
34 M16 M1 ™
ET2A-8PE UL
polyamide EC9E-H3M20E-
IECEx TUR 15.0043U, 22
M20 M2 ™
TÜV 15 ATEX 7799U UL
Signaling Lights

101
EC9E-H3M25E-
123 M25 M3 ™
1 column UL
(1 to 3 control units) EC9E-H3M32E-
F terminal style M32 M4 ™
2, 3 columns UL
finger-safe screw terminal (2, 3 control units) EC9E-H3NPT1E-
IP20 clamp terminal: 264-238 (WAGO) 32 NPT 1/2 N1 ™
UL
polyamide
IECEx PTB 04.0003U, PTB 98 ATEX EC9E-H3NPT2E-
NPT 3/4 N2 ˜
3129U UL
22

84 EC9E-H3NPT3E-
NPT 1 N3 ™
96 UL
Relays & Sockets

EC9E-H4M25E-
M25 M3 ™
UL
The number of terminal blocks, poles, and the installation direction that can be
EC9E-H4M32E-
installed on the control box are as follows: M32 M4 ™
UL
1-column 1, 2 units 1-column 3 units 1-column 4, 5 units 2-column 2, 3 units 1, 2, 3 columns EC9E-H4M40E-
(1 terminal block (1 terminal block (1 terminal block (2 terminal blocks M40 M5 ™
/8 poles) / 8 poles) / 8 poles) /16 poles) (4, 5 control units) UL
3 columns EC9E-H4NPT2E-
NPT 3/4 N2 ™
(6 control units) UL
EC9E-H4NPT3E-
NPT 1 N3 ˜
UL
EC9E-H4NPT4E-
NPT 1 1/4 N4 ™
UL
Timers

2-column 4,5 units 3-column 2, 3 units 3-column 4, 5, 6 units


(4 terminal blocks/ 32 (3 terminal blocks/ 24 (6 terminal blocks/ 8
poles) poles) poles) ˜: Standard reducer ™: non-standard reducer

The reducers in the table above are for replacement use only. All EC2B boxes are
supplied with a reducer that has been secured to the housing per UL regulations.
If it is necessary to replace a reducer, the user should follow appropriate UL stan-
dards for securing to EC2B housing.
Contactors
Terminal Blocks
Circuit Breakers

766 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Accessories

Nameplates Nameplate Inserts


Used for pilot light, pushbutton, selector switch, and key selector switch. Appearance Legend Part Number
Appearance Part Number Dimensions Blank EU9Z-NP0

40 Marking Plate ON EU9Z-NP1


(35) 4.5 OFF EU9Z-NP2

(6.5)
START EU9Z-NP3

Signaling Lights
EU9Z-NM STOP EU9Z-NP4

28.5
OFF-ON EU9Z-NP31
HAND-AUTO EU9Z-NP35
ø4 1.5
0 HAND-OFF-AUTO EU9Z-NP53
All dimensions in mm
Material: Aluminum
Rubber Boots Installing the insert to the nameplate Removing the insert from the nameplate
Insert
Appearance Description/Usage Part Number ➁ Flat screwdriver

Relays & Sockets


For Flush Pushbuttons
Insert
Not for use with name
EU9Z-DB1
plate ➀
Nameplate

For Flush Pushbuttons


Emergency Stop Switch Nameplate Stickers
Appearance Legend Part Number Dimensions
For use with name plate EU9Z-DB1N
EU9Z-NVS0 EU9Z-NVS27

For Extended Pushbuttons ø58 EM


E R GE NCY
ø5

Timers
Blank EU9Z-NVS0
Not for use with name
EU9Z-DB2 ø40 ø4
plate .5
STOP

For Extended Pushbuttons EU9Z-NVS0 EU9Z-NVS27

ø58 ø58
E R GE NCY
EM
For use with name plate EU9Z-DB2N
Emergency Stop EU9Z-NVS27

Contactors
ø40 ø40
.5 .5
STOP

Material: yellow synthetic paper Legend: black

Padlock Cover Emergency Stop Switch Padlock Cover


EU2B-YB2 extended pushbutton: to maintain latched status Used with EU2B-YBV emergency stop switch to maintain the switch in the
EU2B-YB1 flush pushbutton/EU2B-YSK key selector switch: to prevent operation latched status.

Terminal Blocks
Part Part
Appearance Dimensions Appearance Dimensions
Number Number
32.1 Base
46

46

EU9Z-PC
EU9Z-PCE

44 8 24.5 50 8
Circuit Breakers

55.4 32.2
Note: mounted to outside of enclosure with screws, not provided by IDEC
Material: Stainless Steel Coating: yellow Material: Stainless Steel

1705151134
800-262-IDEC (4332) • USA & Canada 767
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Mounting Hole Plug Buttons


Used to plug unused mounting holes (ø30.5) on the mounting panel. Appearance Style Part Number Button Color Code
Part
Appearance Dimensions / Usage
Number
23.2
Flush HW1A-B1➀

Specify a color code in place of


➀ in the Ord ering Number.
EU9Z-BP R : red

ø40
Extended HW1A-B2➀ G : green
Signaling Lights

B : black
13.3 1.0 to 10.5 Y : yellow
(panel thickness) W : white
S : blue
Lenses
ø40 Mushroom HW1A-B4➀
Appearance Lens Color Part Number
Red EU9Z-LR
Green EU9Z-LG Material: Polyacetal

Amber EU9Z-LA
Relays & Sockets

Yellow EU9Z-LY
White EU9Z-LW
Blue EU9Z-LS
Material: AS resin (gasket supplied)

Control Box Shade LED Lamps


Dimensions (mm)
Applicable
Shape Part No. Control Box
H W D
Timers

EC2B-11*B Current Draw


EC9Z-F2A21M 180 160 160 Operating Part Illumination Color
EC2B-21*B Base
Voltage AC DC Number Code
EC9Z-F2A31M EC2B-31*B 230 160 160 7mA Specify a color code
D W EC2B-41*B 6V AC/ (A, R, W) in place of ➀ in the
EC9Z-F2A51 360 160 160 8mA LSTD-6➀
EC2B-51*B DC±10% 5.5mA part number
H
(G, PW, S) R : red
EC2B-22*B G : green
EC9Z-F2A32 260 420 160 12V AC/
EC2B-32*B 11mA 10mA LSTD-1➀ A : amber BA9S/13
DC±10%
PW : white
Contactors

EC2B-42*B
EC9Z-F2A52 360 420 160 S : blue
EC2B-52*B 24V AC/ Use a white (PW)
11mA 10mA LSTD-2➀
Material: stainless steel EC2B-23*B DC±10% LED with yellow (Y)
Thickness: 1mm EC9Z-F2A33 260 510 160 lens.
Photo: Part No. EC9Z-F2A52 EC2B-33*B
EC2B-43*B
EC9Z-F2A53 360 510 160
EC2B-53*B
EC9Z-F2A63 EC2B-63*B 410 510 160
Terminal Blocks

Protects control units from direct sunlight and rain. The surface of the control box shade is uncoated.
Can be installed by tightening to the mounting tabs on the control box.
Circuit Breakers

768 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Operating Instructions

Installation Area ➀ Apply 10A to 1 circuit, 1A to the remaining 7 circuits:


Do not install the EC2B control box in an environment where more than IP65 {(10A × 1.1)2 × 2 wires} + {(1A ×1.1)2 × 14 wires} ≈ 259 (can be used because
protection degree (more than Type 4X in North America) is required. < 300)
Use the EC2B control box under ambient temperature of –20 to +50°C. If the ➁ Apply 10A to 1 circuit, 2A to the remaining 7 circuits:
control box is exposed to direct sunlight and the surface temperature may rise {(10A × 1.1)2 × 2 wires} + {(2A × 1.1)2× 14 wires} ≈ 310 (cannot be used
above 50°C, provide a shade to keep the surface temperature below 50°C. because > 300)
Installation See the table below for the allowable operating current when applying current

Signaling Lights
Use four M6 bolts for 1-column, four M8 bolts for 2- and 3-column, or other methods
evenly to each control box.
with equivalent strength to install the control box. Mounting tab thickness is 1.5mm for 1
column and 2mm for 2, 3, and 4 columns. Allowable Operating Current
If bolts become may loose due to vibration, use spring washers. Max No. of Wires per Bundle (*1) Allowable
Control [wires] ([wires]×[bundle]) Operating
If bolt corrosion is anticipated, use anti-corrosion bolts or other countermea- Max. No.
Box Current
sures. of Circuits Without terminal- With terminal
Part No. (reference)
blocks blocks (*2)
Notes on Emergency Stop Switches
When using the emergency stop switches on safety-related parts of the control EC2B-11 3 16 (16×1) 8 (8×1) 7A

Relays & Sockets


system, observe safety standards and regulations of the relevant country or EC2B-21 6 16 (16×1) 8 (8×1) 5A
region. Also be sure to perform a risk assessment before operation. EC2B-31 9 16 (16×1) 8 (8×1) 4A
Opening/Closing the Lid EC2B-41 12 16 (16×1) 16 (16×1) 3A

Use a Philips screwdriver to loosen lid mounting screws. While holding the EC2B-51 15 16 (16×1) 16 (16×1) 3A
unhinged side, open the lid slowly without exerting excessive force on the hinge. EC2B-22 12 32 (16×2) 16 (8×2) 5A

Before closing the lid, make sure of the following: EC2B-32 18 32 (16×2) 16 (8×2) 4A
EC2B-42 24 32 (16×2) 32 (16×2) 3A
No foreign substances are on the packing or joint surfaces.
EC2B-52 30 32 (16×2) 32 (16×2) 3A
No displacement of the waterproof packing.
EC2B-23 18 48 (16×3) 24 (8×3) 5A

Timers
Wires are not caught between the joint surfaces. EC2B-33 27 48 (16×3) 24 (8×3) 4A
Next, close the lid slowly and tighten the screws to a proper torque of 1.6 to 2.4 EC2B-43 36 48 (16×3) 48 (16×3) 3A
N·m. EC2B-53 45 48 (16×3) 48 (16×3) 3A
Limitation of the Operating Current EC2B-63 54 48 (16x3) 48 (16x3) 3A
Major heat sources comes from the wiring which is connected to the control *1: Make sure that the number of wires per bundle is a maximum of 16 by reducing the wiring or by
box. Therefore, not only the operating current but wiring conditions (size, no. of jumper wiring. The maximum number of wires per bundle may need to be further reduced depending
wires, no. of wire bundles) may cause temperature rise. When wiring, observe on the wire size, lead-in fitting, or conduit size.
*2: The allowable current value (reference) when applying current evenly to all circuits of the maximum
the following conditions.

Contactors
number of circuits.
Stranded wire: 1.5 to 2.5 mm2 (UL-c-UL certified) / Solid wire: ø1.2 to ø1.6 mm
(16 to 14 AWG)
Maximum no. of wires per bundle: 16
Maximum operating current: 10A
When using the control box under an operating environment of 40°C minimum,
use a heat resistant cable of 70°C minimum.

Terminal Blocks
Determine the operating current so that the total heat value of 1 wire bundle is
below 300 [A2 × wires]. Also, when calculating the heat value, take the current
fluctuation (10%) into consideration. [calculation example: EC2B-41**B (8
circuit)]
Circuit Breakers

1705151134
800-262-IDEC (4332) • USA & Canada 769
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Wiring
Wiring Construction EU2B-YB/ YBV ➀
➀ EU2B-YL
Observe the laws and regulations in each country concerning wiring construction. EU2B-YS/ YSK (Lift)
(Lift)

Use cable wiring or metal conduit wiring for installation in hazardous locations. If ➁
➁ (Turn)
foreign objects or water may enter the box, install a sealing fitting near the cable (Turn) TOP

entry of the box and seal the control box using a compound. Standard type control ➂
locking lever

locking lever (Pull) (Pull)
boxes do not contain a terminal block. Wire the control units directly.
Applicable Wires
When the contact unit is removed from the emergency stop switch operator, the
Stranded wire: 1.25 to 2.5 mm2, solid wire: ø1.2 to ø1.6 mm (AWG16 to 14). Do
Signaling Lights

NO contact closes and the NC contact opens.


not connect more than 2 wires to the same terminal. Do not turn the locking lever when the contact unit is removed from the operator
Applicable crimping terminal (the red indicator protruding out, see the figure below) or the switch can be dam-
aged.
Ring and spade terminals cannot be used for EU2B control units with IP20
finger-safe terminals. Ring and spade terminals cannot be used for IP20 clamp
type terminal blocks. When connecting two ferrules to an EU2B control unit, use
ferrules without insulating sheath. locking lever
indicator (red)
(Spade terminal) (Ring terminal) (Ferrule)
Relays & Sockets

Without With
insulating insulating
∗£1.8 max.
∗£1.8 max.
6.9 max.

sheath sheath
6.9 max.

Panel mounting for the operator, lens unit and meter


3.6 min

Insulation
in.
.6m

sheath
Remove the locking ring from the operator and check that the rubber gasket is
ø3

Wire

in place. Insert the operator from the panel front into the panel hole. Place the
3.4 max. 5.5 min. 5.5 min. 8.0 max. 8.0 max.
∗ Dimensions after crimping
projection on the operator with TOP marking upward and the recess on the mount-
ing panel in the same direction. Meters have no projection.
For screw terminal ET2A-8PE For IP20 clamp terminal Tighten the locking ring using ring wrench XN9Z-T1 to a torque of 2.5 Nm. When
(WAGO: 264-238) using a nameplate or padlocking cover, install it between the operator and panel.
(Ring terminal)
(Ring terminal) Make sure that the groove of the namplate or padlocking cover and the projection
on the TOP marking of the operator are in the same direction.
8.5 max.

in.
8.5 max.

in.

.2 m

Insulation sheath
.2 m

Insulation sheath
Note: The locking ring for emergency stop switches and meter is metallic. The
ø4
Timers

ø4

meter can’t mount the nameplate or podlocking cover.


5 to 6.6
5 to 6.6
Installing the contact unit and lamp unit
Recommended crimping terminal (WAGO) Ferrule with insulating sheath: 216-204 To install the contact unit, place the TOP marking on the operator and the TOP
Ferrule without insulating sheath: 216-104 Crimping plier: 206-204 marking on the contact block adapter in the same direction, and then attach the
Recommended Tightening Torque contact unit to the operator. Then turn the locking lever to the right. Follow the
same procedure when installing the lamp unit.
EU2B control units (M3.5) and ET2A-8PE terminal block (M4): 1.0 to 1.3 N·m
When installing the lamp unit, check that the inner lens is not loose.
Contactors

Warning
The contact block adapters for emergency stop Insulation Sheath
Incorrect wiring may cause fire hazard. Observe the following conditions. switches cannot be used for pushbuttons, selector, or
Be sure to install an insulating sheath on the crimping terminal or the crimping key selector switches.
Wire
terminal with insulation. TOP marking Projection 5.5 to 6.0
Nameplate or
Padlocking cover All dimensions in mm.
When connecting solid wires or stranded wires directly, strip the insulation as
Recess on the panel
mentioned below, and insert the wire all the way in.
EU2B Control units: 8.6 mm maximum Rubber
gasket Locking ring
IP20 crimping terminal: 8 to 9 mm
Terminal Blocks

Recess on the
When using stranded wires, make sure that there are no wire whiskers. Make Nameplate
sure that the spade crimping terminals and ferrules are inserted all the way in. Nameplate
gasket
Use insulated ring terminals for the ET2A-8PE terminal block. Use only applicable
crimping terminals and do not directly connect stranded wires or solid wires.
Removing and Installing the Contact Unit / Lamp Unit EU2B-YB
EU2B-YS
EU2B-YL

To remove the contact unit or the lamp unit from the operator, pull the protruding
TOP marking TOP marking
yellow part of the locking lever outwards as shown in the figure below using a

screwdriver, and turn it to the left. The contact unit or lamp unit can be removed.
Circuit Breakers

➁ ➁
TOP
inner lens

770 www.IDEC.com 1705151134


Switches & Pilot Devices ø30mm - EU2B & EC2B Series

Switches & Pilot Devices


Removing the Contact Block When using the padlock cover on the safety-related part of the control system,
To remove the contact block, insert a flat screwdriver under the latch of the con- observe safety standards and regulations of the relevant country or region. Also
tact block adaptor and disengage the latch as shown in the figure below. be sure to perform risk assessment before operation.
Installing EU9Z-PC Padlock Cover
(Flush/extended pushbtton/key selector switch)
EU9Z-PC can be installed in the following two ways.
Remove the cover in the reverse step of installing the cover. Do not install or
remove the cover forcefully, or it will cause failure.
Flat Screwdriver [Installation A]

Signaling Lights
Cover 

Installing the Contact block
When installing the contact block after maintenance or wiring, make sure that the
contact configuration is correct. Installing the contact block in the incorrect posi-
tion or incomplete installation may cause malfunction of the switch. [Installation B]
This method is effective when the neighboring control unit interferes when
Remove the contact block from the operator before installing the contact block installing in method A.
to the contact block adaptor. Also make sure that the contact block is correctly

installed to the contact block adaptor before attaching the operator. Do not install Cover


Relays & Sockets


the contact block adaptor with the operator attached. Otherwise, malfunction may 
result.
Protective Grounding
Protective grounding must be performed according to the installation environment
and rating requirements. Observe laws and regulations set by each country. Installing EU9Z-DB Rubber Boots
Connect the M4 grounding terminal of the EC2B control box to a proper ground To install the rubber boot on flush and extended pushbuttons, place the rubber
(grounding resistance 10Ω maximum). When operating the EC2B control box by boot on the cap and push the rubber boot holder straight. The notches around the
connecting to circuits of 300V or below, the grounding resistance must be 100Ω rubber boot must show evenly.
maximum. Notches
Rubber boot holder
When using cables, connect one of the cable cores to the grounding terminal in

Timers
the enclosure.
Rubber boot
If the grounding terminal in the enclosure cannot be used, use the M4 grounding Notches for
screwdriver
terminal on the outside of the enclosure. Cap
Recommended tightening torque: M4: 1.0 to 1.3 Nm, M6: 3.9 to 5.4 Nm
For grounding, use appropriate wires (size, material, insulation) that can tolerate
the expected maximum grounding current. Be sure to protect the grounding wire Push-in position

with protection, such as metal conduit, from external damage.


Push the rubber boot holder further around on the two notches on the holder so
Accessories that the holder fits the button completely

Contactors
Padlock Cover Make sure that the rubber boot and rubber boot holder are installed straight.
The following padlocks and hasps can be used.
On Nameplate Types, the EU2B and the rubber boot holder must be aligned so
(Padlock Size) a b c that when installed, the anti-rotation projection on the EU2B comes to the center
Flush/extended pushbutton/key selector ø3.5 to 70 mm of the groove on the holder.
15 mm min.
switch 7.0 mm max.
ø5.5 to Make sure that the rubber boot is installed completely, otherwise water droplets
Emergency Stop Switch — — might enter the rubber boot, but no water will enter the control box.
7.0 mm

Recommended Hasp
Terminal Blocks
Manufacturer Part No. Align
Panduit PSL-1, PSL-1A, PSL-1.5, PSL-1.5A, PSL-HD1
Master Lock 420, 421

Padlock and hasp are available in various shapes and sizes. Make sure that they
do not interfere with the control units. Note: Not supplied by IDEC.
Keep the total weight of padlock and hasp under 1500g max, otherwise the
To remove the rubber boot from the flush and extended
switch may malfunction or result in failure. No vibration should be applied when
pushbuttons, gently insert the slotted screwdriver (0.5t x 4w
padlock or hasp are installed. When padlock or hasp are disfigured, stop usage
Circuit Breakers

or below) inside a notch on the rubber boot holder and tilt to


immediately.
the direction shown by the arrow ➀. To prevent damage, do not apply excessive
Ensure that no shock or electric sparks are generated.
force to the EU2B when removing the rubber boot.
When using the plate lock padlock cover with the extended pushbutton, the
switch contact may turn on/off when the cover is being installed. Ensure to
provide functional safety measure to prevent unexpected startup.

1705151134
800-262-IDEC (4332) • USA & Canada 771
Switches & Pilot Devices ø30mm - EU2B & EC2B Series Switches & Pilot Devices

Maintenance and Inspection EC2B Control Boxes


EU2B switches should be installed in an appropriate control box. EC2B control boxes can be installed only in zones 1 and 2. Do not use in zone 0.
In North America, the EC2B can be installed in Division 2 areas, but cannot be
Maintenance and Inspection Method
installed in Division 1 areas.
Perform daily or periodical maintenance and inspection for items such as damage
Turn power off to the EC2B control box before installation, removal, wiring, or
and temperature rise of the EU2B switches listed in the Maintenance and Inspec-
maintenance, otherwise explosion, fire hazard, or electric shock may result.
tion table below.
Special skills and knowledge of explosion protection, electric system installation,
Observe laws and regulations set by each country. Do not open the lid when
and relevant laws/regulations are required to transport, install, wire, operate,
inspecting the EC2B while it is energized. Never disassemble the control box. Do
repair, and inspect the EC2B control box. People without such expertise must not
not use tools that cause sparks during maintenance and inspection. When using
Signaling Lights

use the EC2B control box, otherwise damage or accident may result.
measuring devices, use explosion-protected types. When the EC2B needs to be
disassembled or assembled for maintenance or repair, contact IDEC. Do not modify the EC2B, otherwise damage or accident may result.
Maintenance and Inspection Do not use a damaged EC2B control box, otherwise damage or accident may
Inspection result.
Inspection Items Inspections Measures
Method
 hen connecting external devices, make sure that each cable is connected to the
W
Cleaning
No rusting correct terminal, otherwise electric shock, fire hazard, or explosion may result.
Enclosure base Visual Rust-resistant
No damages
treatment Use wires of a proper size to meet voltage and current requirements. Incorrect
Tightening bolt, No loosening Tightening wiring may cause abnormal temperature rise and lead to fire hazard and explo-
Relays & Sockets

Visual, tactile
screws No rusting Cleaning sion.
No cracks
Packings Visual No apparent Replacement Connect the grounding terminal to a proper ground, otherwise electric shock, fire
deformation hazard, or explosion may result.
No loosening of
Do not sit on or hang from the EC2B control box, otherwise damage, personal
screws Tightening
Connecting parts Visual, tactile injury, or accident may result.
No dirt on insulation Cleaning
materials Do not open the lid of the EC2B control box when it is energized, otherwise
Thermometer, Surface temperature Investigate electric shock, fire hazard, or explosion may result.
Temperature rise
tactile 80ºC max. the cause
Operate the EC2B control box at the rated current and voltage specified in this
Disposal catalog, otherwise short-circuiting, fire hazard, or explosion may result.
Timers

Observe laws and regulations set by each country concerning refuse disposal. When measuring the insulation resistance of the EC2B control box, make sure
that potentially explosive atmosphere of explosive gas or vapor does not exist
Safety Precautions
in the vicinity, otherwise explosion may result. Also, do not touch the terminals
EU2B Control Units without paying attention, otherwise electric shock will result.
Use EU2B switches that are applicable for use in hazardous areas (potentially Do not place any obstacles in front of the nameplate.
explosive atmosphere where explosive gas or vapor may exist), otherwise explo- Do not remove the nameplate.
sion or fire hazard may result.
When opening the lid for wiring, maintenance or inspection, make sure that
Contactors

EU2B switches can be installed only in zones 1 and 2. Do not use in zone 0. substances such as dust, concrete powder, or metal powder do not enter inside
Turn power off to the EU2B switches before installation, removal, wiring, or main- the box, otherwise contact failure or insulation failure may result.
tenance, otherwise explosion, fire hazard, or electric shock may result. Do not drop the EC2B control box during transportation.
Do not disassemble, repair, or modify, otherwise damage or accident may result. Be sure to open the carton the right way up, otherwise damage or personal injury
Do not use damaged EU2B switches, otherwise damage or accident may result. may result.
When connecting external devices, make sure that each cable is connected to the Check that the product is what you have ordered. Using an incorrect model might
correct terminal, otherwise electric shock, fire hazard, or explosion may result. result in malfunction or accident.
Terminal Blocks

Use wires of a proper size to meet voltage and current requirements. Incorrect Stop operation immediately if abnormal operation occurs. Otherwise, a secondary
wiring may cause abnormal temperature rise and lead to fire hazard and explo- accident may occur.
sion. The surface temperature of the EC2B control box may become extremely hot
Connect the grounding terminal to a proper ground, otherwise electric shock, fire during operation. Before maintenance or inspection of the EC2B, be sure to wear
hazard, or explosion may result. gloves to prevent burning your hand.
Operate the EU2B switches at the rated current and voltage specified in this
catalog, otherwise short-circuiting, fire hazard, or explosion may result.
Stop operation immediately if abnormal operation occurs. Otherwise, a secondary
Circuit Breakers

accident may occur.


Use explosion-proof electrical equipment that are applicable for use in hazardous
areas (potentially explosive atmosphere where explosive gas or vapor may exist),
otherwise explosion or fire hazard may result.

772 www.IDEC.com 1705151134