ATEX Detectors Control Distribution Units Zone 1 Zone 2 Heat Detector Ex D Ex em Ex Ia - Eaton HD1 Hazardous Area Control Distribution Units
ATEX Detectors Control Distribution Units Zone 1 Zone 2 Heat Detector Ex D Ex em Ex Ia - Eaton HD1 Hazardous Area Control Distribution Units
ATEX Detectors Control Distribution Units Zone 1 Zone 2 Heat Detector Ex D Ex em Ex Ia - Eaton HD1 Hazardous Area Control Distribution Units
Features
4 Zone 0, Zone 1 and Zone 2 use.
4 ATEX certified.
EExd IIB T3/T6.
Exd IIC T6.
EExem II T4/T6.
Ex ia IIC T4/T6.
4 IECEx certified.
Ex ia IIC T4/T6 Ga.
4 UL listed for USA and Canada:
Class I, Div 2, Groups A-D.
4 CUTR certified.
4 Chinese (CQST) certified
4 Brazilian (Inmetro) certified.
4 SIL 2 certified.
4 IP66 & IP67.
4 Certified temperature: –20ºC to +125ºC (Exd)*.
–20ºC to +55ºC (Exem/UL).
–55ºC to +55ºC (Exia).
4 Stainless steel probe.
4 Detector temperature settings: 60ºC to 385ºC,
Introduction (140ºF to 725ºF).
The MEDC heat detector has been designed for use in hazardous 4 Marine grade alloy or GRP enclosure.
environments. These units are suitable for fire alarm and/or suppression 4 Optional Stainless Steel guard.
systems in offshore and onshore applications including paint spray booths,
flammable material stores, turbine rooms, extract ductwork and other
*Model dependent.
hazardous areas throughout the oil & gas, petrochemical and process
industries.
FIXING CENTRES
Ex II 2 GD, Ex d IIC T6, Ex tD A21 T85ºC (-20ºC to + 55ºC).
105.5±0.5
122±2
ATEX EEx em: Cert. no. Baseefa03ATEX0428.
Certified to: EN50014, EN50019, EN50028.
Ex II 2G, EEx em II T6 (-20ºC to + 55ºC).
ATEX Ex ia: Cert. no. Baseefa03ATEX0427.
Certified to: EN60079-0, EN60079-11. 37±2 FIXING HOLES
Ø9±0.5 - 4 POS.
105.5±0.5
FIXING CENTRES
ABS: American Bureau of Shipping type approval for HD1BBD & HD1B1 only. OPTIONAL
CERTIFICATION
SIL: SIL2 certified. Cert no. Sira FSP 12007/02. LABEL GUARD
Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number
by inserting the code for each component into the appropriate box.
Certification Code Type Code TempºF Code Option Code Finish Code
ATEX B Exd IIB BD 140 140 Duty Label D* Natural Black N
IECEx J Exd IIC CD* 160 160 Tag Label T* (Exe/Exia/UL only)
ATEX/IECEx dual listed AJ Exe E† 190 190 Guard G Grey G
UL listed UL Exia I‡ 210 210 Resistor EOL E* Red R
ATEX/UL dual listed AU UL U 225 225 Resistor series S* Blue B
CUTR G* 275 275 Diode(s) I*† Yellow Y
Chinese (CQST) Q† * Exd IIC only available in ATEX. 325 325 Blanking Plug P Special S*
† ATEX/UL dual listed Exe 360 360
Inmetro M None N
version only.
450 450 * Please specify.
* Russian Fire Approved as standard. ‡ IECEx and ATEX/IECEx dual
listed only available Exia.
500 500 * Please specify
† Only available Ex ia certified. † Only available in ATEX Exd IIB
Not for use in China on fire alarm 600 600
725 725 or Exia versions (specify value).
systems.
All specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice.
No liability is accepted for any consequence of use.