PRO 35 CARDIOID CONDENSER CLIP-ON

INSTRUMENT MICROPHONE

PRO 35 SPECIFICATIONS†
ELEMENT Fixed-charge back plate
permanently polarized condenser
POLAR PATTERN Cardioid
FREQUENCY RESPONSE 50-15,000 Hz
LOW FREQUENCY ROLL-OFF 80 Hz, 18 dB/octave
OPEN CIRCUIT SENSITIVITY –45 dB (5.6 mV) re 1V at 1 Pa*
IMPEDANCE 250 ohms
MAXIMUM INPUT SOUND LEVEL 145 dB SPL, 1 kHz at 1% THD
DYNAMIC RANGE (typical) 115 dB, 1 kHz at Max SPL
SIGNAL-TO-NOISE RATIO1 64 dB,1 kHz at 1 Pa*
PHANTOM POWER REQUIREMENTS 11-52V DC, 2 mA typical
SWITCH Flat, roll-off
WEIGHT (less cable and accessories)
MICROPHONE 0.3 oz (8 g)
POWER MODULE 2.9 oz (81 g)
DIMENSIONS
MICROPHONE 0.98" (25.0 mm) long,
0.40" (10.2 mm) diameter
POWER MODULE 3.66" (92.9 mm) long,
0.74" (18.9 mm) diameter
OUTPUT CONNECTOR Integral 3-pin XLRM-type
(power module)
CABLE 6.0' (1.8 m) long (permanently
attached to microphone),
0.10" (2.6 mm) diameter,
2-conductor, shielded cable with
• Ideal for sax, toms, brass and percussion TA3F-type connector
ACCESSORIES FURNISHED AT8418 UniMount® microphone
• Excels in high-SPL applications instrument mount; AT8538 power
module; soft protective pouch
• Perfect for active stage performances
†In the interest of standards development, A.T.U.S. offers full details on its test
• Extended frequency response captures subtle nuances of the methods to other industry professionals on request.
*1 Pascal = 10 dynes /cm 2 = 10 microbars = 94 dB SPL
performance 1
Typical, A-weighted, using Audio Precision System One.
Specifications are subject to change without notice.
• UniMount® clip permits accurate positioning, provides shock
resistance and protects element

• Corrosion-resistant contacts from gold-plated XLRM-type


Polar Pattern Frequency Response
connector

• Cardioid polar pattern reduces pickup of sounds from the sides

Response in dB
and rear, improving isolation of desired sound source

The PRO 35 is intended for use in professional applications where


r e m o t e p owe r is available. It requires 11V to 52 V D C
phantom power, which may be provided by a mixer or console, or Frequency in Hertz
by a separate, in-line source such as the Audio-Technica AT8801 LEGEND 12" or more on axis

single-channel or CP8506 four-channel phantom power supplies. LEGEND


SCALE IS 5 DECIBELS PER DIVISION Roll-off

200 Hz
1 kHz
5 kHz
8 kHz

An integral 80 Hz high-pass filter provides easy switching from a flat


frequency response to a low-end roll-off. The roll-off position
reduces the pickup of low-frequency ambient noise (such as traffic,
air-handling systems, etc.), room reverberation and mechanically
coupled vibrations.

Output from the power module’s XLRM-type connector is low


impedance (Lo-Z) balanced. The signal appears across Pins 2 and
3; Pin 1 is ground (shield). Output phase is “Pin 2 hot” – positive
acoustic pressure produces positive voltage at Pin 2.

To avoid phase cancellation and poor sound, all mic cables must be
wired consistently: Pin 1-to-Pin 1, etc.

Avoid leaving the microphone in the open sun or in areas where


temperatures exceed 110° F (43° C) for extended periods.
Extremely high humidity should also be avoided.

Audio-Technica U.S., Inc., 1221 Commerce Drive, Stow, Ohio 44224


Audio-Technica Limited, Old Lane, Leeds LS11 8AG England
www.audio-technica.com
P51764 ©2005 Audio-Technica U.S., Inc. Printed in Japan

PRO 35 MICROPHONE POUR INSTRUMENT


CARDIOÏDE À CONDENSATEUR À PINCE

PRO 35 CARACTÉRISTIQUES TECHNIQUES†


TYPE Condensateur polarisé en
permanence avec plaque fixe à
charge fixe
DIRECTIVITÉ Cardioïde
RÉPONSE EN FRÉQUENCE 50-15 000 Hz
ATTÉNUATION DES GRAVES 80 Hz, 18 dB/octave
NIVEAU DE SORTIE –45 dB (5,6 mV) réf 1V/Pa*
IMPÉDANCE 250 ohms
NIVEAU DE PRESSION 145 dB SPL, 1 kHz à 1% T.H.D.
ACOUSTIQUE MAXIMAL
DYNAMIQUE (typique) 115 dB, 1 kHz à SPL max.
RAPPORT SIGNAL/BRUIT1 64 dB, 1 kHz/Pa*
ALIMENTATION FANTÔME 11-52V CC, 2 mA typiques
COMMUTATEUR Plat, atténuation
POIDS (sans le câble et les accessoires)
MICROPHONE 8 g (0,3 oz)
MODULE D’ALIMENTATION 81 g (2,9 oz)
DIMENSIONS
MICROPHONE Longueur 25,0 mm (0,98"),
diamètre 10,2 mm (0,40")
MODULE D’ALIMENTATION Longueur 92,9 mm (3,66"),
diamètre 18,9 mm (0,74")
CONNECTEUR DE SORTIE Type XLRM 3 broches intégré
(module d’alimentation)
CÂBLE Câble blindé à 2 conducteurs, de
2,6 mm de diamètre (0,10 po) et
• Idéal pour le saxophone, les toms, les cuivres et les percussions 1,8 m de long (6,0 pi) (solidaire du
microphone), avec connecteur de
• Excelle dans les applications avec niveau de pression acoustique sortie TA3F
élevé
ACCESSOIRES FOURNIS AT8418 fixation de microphone sur
• Convient parfaitement pour les performances scéniques non instrument UniMount®; AT8538
module d’alimentation; étui souple
statiques de protection
• Réponse en fréquence étendue rendant toutes les nuances †Afin de contribuer au développement des normes, A.T.U.S. fournit tout renseignement sur
subtiles de la performance ses méthodes de test aux professionnels de l’industrie qui en font la demande.
*1 Pascal = 10 dynes/cm2 = 10 microbars = 94 dB SPL
1
Typique, pondéré en A, mesuré avec l’ Audio Precision System One.
• Clip UniMount® permettant un positionnement précis, fournissant Les caractéristiques techniques sont soumises à des changements sans préavis.
une résistance aux chocs et protégeant la capsule
• Contacts des connecteurs de type XLRM plaqués or, résistants à
la corrosion
Directivité Réponse en Fréquence

• Directivité cardioïde pour une meilleure isolation de la source


sonore et une réduction de la prise de son latérale et arrière
Réponse - dB

Le PRO 35 est destiné à être utilisé dans des applications


professionnelles pour lesquelles on dispose déjà d’une source
d’alimentation externe. Il requiert une alimentation fantôme de 11 à
52V CC qui peut être fournie par un mélangeur ou une console ou
par une source indépendante à brancher en série telle que Fréquence - Hertz

l’alimentation fantôme AT8801 canal unique ou CP8506 quatre LÉGENDE


ÉCHELLE: 5 dB PAR DIVISION
LÉGENDE 12" ou plus sur l'axe
Pente de diminution
canaux d’Audio-Technica. 200 Hz
1 kHz
5 kHz
8 kHz

Un filtre passe-haut 80 Hz intégré permet de passer facilement


de la réponse en fréquence plate à l’atténuation des graves. La
position passe-haut sert à réduire la sensibilité aux bruits ambiants
de basse fréquence (dus au trafic, aux installations de ventilation,
etc.), à la réverbération de la pièce et aux vibrations couplées
mécaniquement.
La sor tie du module d’alimentation est symétrique basse
impédance, elle se fait sur une embase XLRM 3 broches. Le signal
symétrique est entre les broches 2 et 3, le point chaud est en deux
(la tension positive sur le point chaud est générée par une pression
acoustique positive sur la capsule). La masse (blindage) est sur la
broche 1.

Pour éviter une annulation de la phase et un son de mauvaise


qualité, tous les câbles de micro doivent être raccordés de manière
consistante : broche 1 avec broche 1, etc.
Evitez de laisser le microphone en plein soleil ou dans des endroits Audio-Technica U.S., Inc., 1221 Commerce Drive, Stow, Ohio 44224
où la température est supérieure à 43°C (110°F) pendant une Audio-Technica Limited, Old Lane, Leeds LS11 8AG Angleterre
durée prolongée. Une trop forte humidité doit également être www.audio-technica.com
évitée. P51764 ©2005 Audio-Technica U.S., Inc. Imprimé au Japon